1
|
Striegel AM. On-line coupling of hollow-fiber flow field-flow fractionation and depolarized multi-angle static light scattering (HF5/D-MALS). Proof of principle. J Chromatogr A 2024; 1730:465115. [PMID: 38936166 PMCID: PMC11345793 DOI: 10.1016/j.chroma.2024.465115] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/06/2024] [Revised: 06/20/2024] [Accepted: 06/22/2024] [Indexed: 06/29/2024]
Abstract
Introduced here is the on-line coupling of hollow-fiber flow field-flow fractionation (HF5) to depolarized multi-angle static light scattering (D-MALS). HF5 is a size-based separation alternative to size-exclusion and hydrodynamic chromatography and asymmetric flow field-flow fractionation. HF5 can separate larger sizes than its chromatographic counterparts and provides several advantages over its fractionation counterpart, including reduced sample consumption and greater ease of operation. D-MALS is a variant of MALS in which the depolarized scattering from the analyte solution is measured at a variety of angles simultaneously. Measurements of depolarized scattering have previously been employed in studying the optical properties of solutions or suspensions, to determine the length of rod-like analytes, and to gain increased accuracy in the determination of analyte molar mass. The coupling HF5/D-MALS allows for the depolarization ratio of a solution or suspension to be measured continuously across the fractogram. This is demonstrated here for a Teflon latex the size range of which extends beyond that accessible to commercial size-exclusion columns. The results presented provide the first reported on-line HF5/D-MALS coupling, showing the feasibility of the technique as well as its realized potential for providing continuous depolarization measurements, inter alia.
Collapse
Affiliation(s)
- André M Striegel
- Chemical Sciences Division, National Institute of Standards and Technology (NIST), 100 Bureau Drive, MS 8390, Gaithersburg, MD 20899-8390, USA.
| |
Collapse
|
2
|
Clobes ML, Kozliak EI, Kubátová A. Advancing Molecular Weight Determination of Lignin by Multi-Angle Light Scattering. Polymers (Basel) 2024; 16:477. [PMID: 38399853 PMCID: PMC10892000 DOI: 10.3390/polym16040477] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/04/2024] [Revised: 02/01/2024] [Accepted: 02/05/2024] [Indexed: 02/25/2024] Open
Abstract
Due to the complexity and recalcitrance of lignin, its chemical characterization is a key factor preventing the valorization of this abundant material. Multi-angle light scattering (MALS) is becoming a sought-after technique for absolute molecular weight (MW) determination of polymers and proteins. Lignin is a suitable candidate for MW determination via MALS, yet further investigation is required to confirm its absolute MW values and molecular size. Studies aiming to break down lignin into a variety of renewable products will benefit greatly from a simple and reliable determination method like MALS. Recent pioneering studies, discussed in this review, addressed several key challenges in lignin's MW characterization. Nevertheless, some lignin-specific issues still need to be considered for in-depth characterization. This study explores how MALS instrumentation manages the complexities of determining lignin's MW, e.g., with simultaneous fractionation and fluorescence interference mitigation. Additionally, we rationalize the importance of a more detailed light scattering analysis for lignin characterization, including aspects like the second virial coefficient and radius of gyration.
Collapse
Affiliation(s)
| | - Evguenii I. Kozliak
- Department of Chemistry, University of North Dakota, 151 Cornell St., Stop 9024, Grand Forks, ND 58202, USA;
| | - Alena Kubátová
- Department of Chemistry, University of North Dakota, 151 Cornell St., Stop 9024, Grand Forks, ND 58202, USA;
| |
Collapse
|
3
|
Wiedmer SK, Riekkola ML. Field-flow fractionation - an excellent tool for fractionation, isolation and/or purification of biomacromolecules. J Chromatogr A 2023; 1712:464492. [PMID: 37944435 DOI: 10.1016/j.chroma.2023.464492] [Citation(s) in RCA: 12] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/17/2023] [Revised: 10/30/2023] [Accepted: 11/03/2023] [Indexed: 11/12/2023]
Abstract
Field-flow fractionation (FFF) with its several variants, has developed into a mature methodology. The scope of the FFF investigations has expanded, covering both a wide range of basic studies and especially a wide range of analytical applications. Special attention of this review is given to the achievements of FFF with reference to recent applications in the fractionation, isolation, and purification of biomacromolecules, and from which especially those of (in alphabetical order) bacteria, cells, extracellular vesicles, liposomes, lipoproteins, nucleic acids, and viruses and virus-like particles. In evaluating the major approaches and trends demonstrated since 2012, the most significant biomacromolecule applications are compiled in tables. It is also evident that asymmetrical flow field-flow fractionation is by far the most dominant technique in the studies. The industry has also shown current interest in FFF and adopted it in some sophisticated fields. FFF, in combination with appropriate detectors, handles biomacromolecules in open channel in a gentle way due to the lack of shear forces and unwanted interactions caused by the stationary phase present in chromatography. In addition, in isolation and purification of biomacromolecules quite high yields can be achieved under optimal conditions.
Collapse
Affiliation(s)
- Susanne K Wiedmer
- Department of Chemistry, POB 55, 00014 University of Helsinki, Finland
| | | |
Collapse
|
4
|
Bian J, Gobalasingham N, Purchel A, Lin J. The Power of Field-Flow Fractionation in Characterization of Nanoparticles in Drug Delivery. Molecules 2023; 28:molecules28104169. [PMID: 37241911 DOI: 10.3390/molecules28104169] [Citation(s) in RCA: 12] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/31/2023] [Revised: 05/11/2023] [Accepted: 05/15/2023] [Indexed: 05/28/2023] Open
Abstract
Asymmetric-flow field-flow fractionation (AF4) is a gentle, flexible, and powerful separation technique that is widely utilized for fractionating nanometer-sized analytes, which extend to many emerging nanocarriers for drug delivery, including lipid-, virus-, and polymer-based nanoparticles. To ascertain quality attributes and suitability of these nanostructures as drug delivery systems, including particle size distributions, shape, morphology, composition, and stability, it is imperative that comprehensive analytical tools be used to characterize the native properties of these nanoparticles. The capacity for AF4 to be readily coupled to multiple online detectors (MD-AF4) or non-destructively fractionated and analyzed offline make this technique broadly compatible with a multitude of characterization strategies, which can provide insight on size, mass, shape, dispersity, and many other critical quality attributes. This review will critically investigate MD-AF4 reports for characterizing nanoparticles in drug delivery, especially those reported in the last 10-15 years that characterize multiple attributes simultaneously downstream from fractionation.
Collapse
Affiliation(s)
- Juan Bian
- Genentech Research and Early Development, Genentech Inc., 1 DNA Way, South San Francisco, CA 94080, USA
| | - Nemal Gobalasingham
- Wyatt Technology Corporation, 6330 Hollister Ave, Santa Barbara, CA 93117, USA
| | - Anatolii Purchel
- Wyatt Technology Corporation, 6330 Hollister Ave, Santa Barbara, CA 93117, USA
| | - Jessica Lin
- Genentech Research and Early Development, Genentech Inc., 1 DNA Way, South San Francisco, CA 94080, USA
| |
Collapse
|
5
|
Burton JB, Carruthers NJ, Stemmer PM. Enriching extracellular vesicles for mass spectrometry. MASS SPECTROMETRY REVIEWS 2023; 42:779-795. [PMID: 34632607 DOI: 10.1002/mas.21738] [Citation(s) in RCA: 18] [Impact Index Per Article: 9.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/18/2021] [Revised: 09/19/2021] [Accepted: 09/24/2021] [Indexed: 06/13/2023]
Abstract
Extracellular vesicles from plasma, other body fluids and cell culture media hold great promise in the search for biomarkers. Exosomes in particular, the vesicle type that is secreted after being produced in the endocytic pathway and having a diameter of 30-150 nm, are considered to be a conveyance for signaling molecules and, therefore, to hold valuable information regarding the health and activity status of the cells from which they are released. The vesicular nature of exosomes is central to all methods used to separate them from the highly abundant proteins in plasma and other fluids. The enrichment of the vesicles is essential for mass spectrometry-based analysis as they represent only a very small component of all plasma proteins. The progression of isolation techniques for exosomes from ultracentrifugation through chromatographic separation using hydrophobic packing materials shows that effective enrichment is possible and that high throughput approaches to exosome enrichment are achievable.
Collapse
Affiliation(s)
- Jordan B Burton
- Institute of Environmental Health Sciences, Wayne State University, Detroit, Michigan, USA
| | | | - Paul M Stemmer
- Institute of Environmental Health Sciences, Wayne State University, Detroit, Michigan, USA
| |
Collapse
|
6
|
Gopalakrishnan A, Bouby M, Schäfer AI. Membrane-organic solute interactions in asymmetric flow field flow fractionation: Interplay of hydrodynamic and electrostatic forces. THE SCIENCE OF THE TOTAL ENVIRONMENT 2023; 855:158891. [PMID: 36411600 DOI: 10.1016/j.scitotenv.2022.158891] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/23/2022] [Revised: 09/16/2022] [Accepted: 09/16/2022] [Indexed: 06/16/2023]
Abstract
The structure and size characterization of organic matter (OM) using flow field-flow fractionation (FFFF) is interesting due to the numerous interactions of OM in aquatic systems and water treatment processes. The estimation of hydrodynamic and electrostatic forces involved in the fractionation of OM over different molecular weight cut-off (MWCO) membranes is vital for a better understanding of the FFFF process. This work aims to understand the membrane-OM interactive forces with respect to membrane MWCO, solute molecular weight, flow rates, solution pH and ionic strength. Polystyrene sulfonate sodium salt (PSS) of molecular weights 10, 30 and 65 kDa were used as model organic solutes for fractionation over ultrafiltration (UF) membranes of MWCO 1-30 kDa. Maximum fractionation of PSS was achieved by using a tight membrane of 1 kDa MWCO at the conditions of high permeate flow rate (1.5-2.0 mL·min-1), low concentrate flow rate (0.2-0.3 mL·min-1) and low ionic strength (10 mM). The better fractionation corresponds to high permeate drag force and low concentrate drag force. A low membrane-solute DLVO interaction is favourable for the retention of a small solute. This study illustrated that FFFF characteristics can be analyzed based on membrane-solute interactive forces controlled by selected flow, size and charge parameters.
Collapse
Affiliation(s)
- Akhil Gopalakrishnan
- Institute for Advanced Membrane Technology (IAMT), Karlsruhe Institute of Technology (KIT), Hermann-von-Helmholtz-Platz 1, 76344 Eggenstein-Leopoldshafen, Germany
| | - Muriel Bouby
- Institute for Nuclear Waste Disposal (INE), Karlsruhe Institute of Technology (KIT), Hermann-von-Helmholtz-Platz 1, 76344 Eggenstein-Leopoldshafen, Germany
| | - Andrea I Schäfer
- Institute for Advanced Membrane Technology (IAMT), Karlsruhe Institute of Technology (KIT), Hermann-von-Helmholtz-Platz 1, 76344 Eggenstein-Leopoldshafen, Germany.
| |
Collapse
|
7
|
Loeschner K, Vidmar J, Hartmann NB, Bienfait AM, Velimirovic M. Finding the tiny plastic needle in the haystack: how field flow fractionation can help to analyze nanoplastics in food. Anal Bioanal Chem 2023; 415:7-16. [PMID: 36085421 DOI: 10.1007/s00216-022-04321-y] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/07/2022] [Revised: 08/31/2022] [Accepted: 09/03/2022] [Indexed: 01/11/2023]
Abstract
While the exact health risks associated with nanoplastics are currently the focus of intense research, there is no doubt that humans are exposed to nanoplastics and that food could be a major source of exposure. Nanoplastics are released from plastic materials and articles used during food production, processing, storage, preparation, and serving. They are also likely to enter the food chain via contaminated water, air, and soil. However, very limited exposure data for risk assessment exists so far due to the lack of suitable analytical methods. Nanoplastic detection in food poses a great analytical challenge due to the complexity of plastics and food matrices as well as the small size and expectedly low concentration of the plastic particles. Multidetector field flow fractionation has emerged as a valuable analytical technique for nanoparticle separation over the last decades, and the first studies using the technique for analyzing nanoplastics in complex matrices are emerging. In combination with online detectors and offline analysis, multidetector field flow fractionation is a powerful platform for advanced characterization of nanoplastics in food by reducing sample complexity, which otherwise hampers the full potential of most analytical techniques. The focus of this article is to present the current state of the art of multidetector field flow fractionation for nanoplastic analysis and to discuss future trends and needs aiming at the analysis of nanoplastics in food.
Collapse
Affiliation(s)
- Katrin Loeschner
- National Food Institute, Technical University of Denmark, Kemitorvet 201, 2800, Kgs. Lyngby, Denmark.
| | - Janja Vidmar
- Department of Environmental Sciences, Jožef Stefan Institute, Jamova 39, 1000, Ljubljana, Slovenia
| | - Nanna B Hartmann
- Department of Environmental and Resource Engineering, Technical University of Denmark, Bygningstorvet 115, 2800, Kgs. Lyngby, Denmark
| | | | - Milica Velimirovic
- Flemish Institute for Technological Research (VITO), Boeretang 200, 2400, Mol, Belgium.,Department of Chemistry, Atomic & Mass Spectrometry - A&MS research group, Ghent University, Campus Sterre, Krijgslaan 281-S12, 9000, Ghent, Belgium
| |
Collapse
|
8
|
Absolute molar mass determination in mixed solvents. 2. SEC/MALS/DRI in a mix of two “nearly-isovirial” solvents. Anal Chim Acta 2022; 1231:340369. [DOI: 10.1016/j.aca.2022.340369] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/13/2022] [Revised: 09/01/2022] [Accepted: 09/06/2022] [Indexed: 11/22/2022]
|
9
|
Striegel AM. Size-Exclusion Chromatography: A Twenty-First Century Perspective. Chromatographia 2022; 85:10.1007/s10337-022-04143-1. [PMID: 36620523 PMCID: PMC9813945 DOI: 10.1007/s10337-022-04143-1] [Citation(s) in RCA: 10] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/12/2023]
Abstract
Now in its sixth decade, size-exclusion chromatography (SEC) remains the premier method by which to determine the molar mass averages and distributions of natural and synthetic macromolecules. Aided by its coupling to a variety and multiplicity of detectors, it has also shown its ability to characterize a host of other physicochemical properties, such as branching, chemical, and sequence length heterogeneity size distribution; chain rigidity; fractal dimension and its change as a function of molar mass; etc. SEC is also an integral part of most macromolecular two-dimensional separations, providing a second-dimension size-based technique for determining the molar mass of the components separated in the first dimension according to chemical composition, thus yielding the combined chemical composition and molar mass distributions of a sample. While the potential of SEC remains strong, our awareness of the pitfalls and challenges inherent to it and to its practice must also be ever-present. This Perspective aims to highlight some of the advantages and applications of SEC, to bring to the fore these caveats with regard to its practice, and to provide an outlook as to potential areas for expansion and growth.
Collapse
Affiliation(s)
- André M. Striegel
- Chemical Sciences Division, National Institute of Standards and Technology (NIST), 100 Bureau Drive, MS 8390, Gaithersburg, MD 20899-8390, USA
| |
Collapse
|