1
|
Molina R, Redondo B, Ortiz C, Vera J, Díaz JA, Jiménez R. Higher order aberrations according to spherical, and astigmatic refractive errors in children. Clin Exp Optom 2024:1-12. [PMID: 38561016 DOI: 10.1080/08164622.2024.2325632] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/06/2022] [Accepted: 02/04/2024] [Indexed: 04/04/2024] Open
Abstract
CLINICAL RELEVANCE The results of this study present novel insights into the impact of spherical and astigmatic refractive errors on overall, corneal and internal aberrations and may provide a clear understanding of the emmetropisation process and the development of visual function. BACKGROUND This study aimed to assess the association between overall, corneal and internal higher-order aberrations and the spherical and astigmatic components (magnitude and angle) of refractive error in a large sample of children. METHODS A total of 311 children aged 7 - 8 years old were classified based on spherical equivalent refraction (myopic, emmetropic and hyperopic); magnitude of astigmatism (none, low and moderate); and angle of astigmatism (with-the-rule, against-the-rule and oblique). Refractive error and overall, corneal and internal higher-order aberrations were measured using the OPD-Scan III workstation. RESULTS Regarding spherical equivalent refraction, myopic eyes had greater root mean square (RMS) overall higher-order values, total spherical, tetrafoil and secondary astigmatism aberrations, and internal higher-order, total spherical and tetrafoil aberrations in comparison to emmetropic eyes. The magnitude of astigmatism was positively associated with all overall RMS aberrations and with internal higher order, coma, total coma, total spherical and tetrafoil aberrations. Eyes with with-the-rule astigmatism showed higher RMS values of coma and total coma compared to eyes with against-the-rule and oblique astigmatism. CONCLUSIONS Higher-order aberrations are dependent on the spherical as well as astigmatic components of refractive error. These findings enhance the current understanding of the emmetropisation process and visual function development.
Collapse
Affiliation(s)
- Rubén Molina
- Department of Optics, University of Granada, Granada, Spain
| | - Beatriz Redondo
- Department of Optics, University of Granada, Granada, Spain
- New England College of Optometry, Boston, Massachusetts
| | - Carolina Ortiz
- Department of Optics, University of Granada, Granada, Spain
| | - Jesús Vera
- Department of Optics, University of Granada, Granada, Spain
- New England College of Optometry, Boston, Massachusetts
| | - José A Díaz
- Department of Optics, University of Granada, Granada, Spain
| | | |
Collapse
|
2
|
Shen L, Wei C, Yang W, Xiong Y, Li Y, Li D, Wang Z, Chen W, Zhao Q, Li Y, Cui R, Liu Q. Analysis of the relationship between lens morphology and aberrations in patients with myopia: a cross-sectional study. Int Ophthalmol 2023; 43:4911-4919. [PMID: 37828345 DOI: 10.1007/s10792-023-02894-w] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/24/2023] [Accepted: 09/27/2023] [Indexed: 10/14/2023]
Abstract
PURPOSE To investigate the relationship between lens morphology and aberrations in patients with myopia. METHODS This cross-sectional study included 155 patients with myopia in their right eyes. Spherical power and cylindrical power were achieved by cycloplegic autorefraction. The eyes were divided into three groups for analysis based on their spherical equivalent (SE) values. The 4 mm and 6 mm ocular and internal aberrations were measured using the OPD-scan III. Lens parameters were measured using CASIA2, including lens thickness (LT), radius of anterior/posterior lens surface curvature (RAL/RPL), lens decentration (DEC), and lens tilt (TILT). The differences of lenticular parameters and aberration parameters among the three groups analyzed with ANOVA or Kruskal Wallis test. Pearson correlation or Spearman correlation analysis was performed to evaluate the relationships between the lens parameters and aberrations. A p value < 0.05 indicated statistical significance. RESULTS The difference in LT, RAL, DEC and TITL among the three groups was statistically significant (p < 0.05). And there were differences among differences in internal high-order aberrations, spherical aberration, and coma aberration(p < 0.05).Spherical power was positively correlated with LT and TITL (p < 0.05) and negatively correlated with DEC, RAL, and RPL (p < 0.05). Cylindrical power was positively correlated with LT (p < 0.05) and negatively correlated DEC (p < 0.05); The lenticular parameters (LT, RAL, DEC, and TILT) were mainly correlated with the ocular and internal spherical aberration. LT and DEC were correlated with ocular and internal higher-order aberrations and coma aberration. CONCLUSION DEC and LT were the main factors affecting aberrations in patients with myopia.
Collapse
Affiliation(s)
- Lin Shen
- Beijing Tongren Eye Center, Beijing Tongren Hospital, Capital Medical University, Beijing Ophthalmology and Visual Sciences Key Laboratory, Beijing, 100730, China
| | - Chuanchuan Wei
- Beijing Tongren Eye Center, Beijing Tongren Hospital, Capital Medical University, Beijing Ophthalmology and Visual Sciences Key Laboratory, Beijing, 100730, China
| | - Wenli Yang
- Beijing Tongren Eye Center, Beijing Tongren Hospital, Capital Medical University, Beijing Ophthalmology and Visual Sciences Key Laboratory, Beijing, 100730, China.
| | - Ying Xiong
- Beijing Tongren Eye Center, Beijing Tongren Hospital, Capital Medical University, Beijing Ophthalmology and Visual Sciences Key Laboratory, Beijing, 100730, China
| | - Yifan Li
- Beijing Tongren Eye Center, Beijing Tongren Hospital, Capital Medical University, Beijing Ophthalmology and Visual Sciences Key Laboratory, Beijing, 100730, China
| | - Dongjun Li
- Beijing Tongren Eye Center, Beijing Tongren Hospital, Capital Medical University, Beijing Ophthalmology and Visual Sciences Key Laboratory, Beijing, 100730, China
| | - Ziyang Wang
- Beijing Tongren Eye Center, Beijing Tongren Hospital, Capital Medical University, Beijing Ophthalmology and Visual Sciences Key Laboratory, Beijing, 100730, China
| | - Wei Chen
- Beijing Tongren Eye Center, Beijing Tongren Hospital, Capital Medical University, Beijing Ophthalmology and Visual Sciences Key Laboratory, Beijing, 100730, China
| | - Qi Zhao
- Beijing Tongren Eye Center, Beijing Tongren Hospital, Capital Medical University, Beijing Ophthalmology and Visual Sciences Key Laboratory, Beijing, 100730, China
| | - Yifeng Li
- Beijing Tongren Eye Center, Beijing Tongren Hospital, Capital Medical University, Beijing Ophthalmology and Visual Sciences Key Laboratory, Beijing, 100730, China
| | - Rui Cui
- Beijing Tongren Eye Center, Beijing Tongren Hospital, Capital Medical University, Beijing Ophthalmology and Visual Sciences Key Laboratory, Beijing, 100730, China
| | - Qian Liu
- Beijing Tongren Eye Center, Beijing Tongren Hospital, Capital Medical University, Beijing Ophthalmology and Visual Sciences Key Laboratory, Beijing, 100730, China
| |
Collapse
|
3
|
Bhardwaj A, Kaur S, Sukhija J, Gupta PC, Ram J. Role of swept-source anterior segment optical coherence tomography in imaging pediatric cataract. Indian J Ophthalmol 2023; 71:2132-2138. [PMID: 37203093 PMCID: PMC10391514 DOI: 10.4103/ijo.ijo_2734_22] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 05/20/2023] Open
Abstract
Purpose To determine the morphology of pediatric cataracts and assess the status of the anterior and posterior capsules preoperatively on swept-source anterior segment optical coherence tomography (ASOCT) and compare the findings to those of intraoperative examination. Secondly, we aimed to obtain biometric measurements on ASOCT and compare them to those obtained on A-scan/optical methods. Methods This was a prospective and observational study carried out at a tertiary care referral institute. ASOCT scans for anterior segment were obtained preoperatively for all patients, aged <8 years, scheduled for paediatric cataract surgery. The morphology of the lens and capsule and biometry were performed on ASOCT and the same were assessed intraoperatively. The main outcome measures were comparison of ASOCT findings to intraoperative findings. Results The study included 33 eyes of 29 patients (range 3 months-8 years). The morphological characterization of cataract on ASOCT was accurate in 31/33 (94%) cases. ASOCT accurately identified fibrosis and rupture of the anterior and posterior capsules in 32/33 (97%) cases each. In 30% of eyes, ASOCT gave additional information preoperatively compared to the slit lamp. Intraclass correlation coefficient (ICC) calculation revealed a good agreement between the keratometry values obtained on ASOCT and those obtained preoperatively with a handheld/optical keratometer (ICC = 0.86, P = 0.001). Conclusion ASOCT is a valuable tool that could provide complete preoperative information of the lens and capsule in pediatric cataract cases. In children as young as 3 months of age, intraoperative risks and surprises could be diminished. The keratometric readings are highly dependent on patient cooperation but show good agreement with the handheld/optical keratometer readings.
Collapse
Affiliation(s)
- Anand Bhardwaj
- Advanced Eye Centre, Post Graduate Institute of Medical Education and Research, Chandigarh, India
| | - Savleen Kaur
- Advanced Eye Centre, Post Graduate Institute of Medical Education and Research, Chandigarh, India
| | - Jaspreet Sukhija
- Advanced Eye Centre, Post Graduate Institute of Medical Education and Research, Chandigarh, India
| | - Parul Chawla Gupta
- Advanced Eye Centre, Post Graduate Institute of Medical Education and Research, Chandigarh, India
| | - Jagat Ram
- Advanced Eye Centre, Post Graduate Institute of Medical Education and Research, Chandigarh, India
| |
Collapse
|
4
|
Mirzayev I, Gündüz AK, Aydın Ellialtıoğlu P, Gündüz ÖÖ. Clinical applications of anterior segment swept-source optical coherence tomography: A systematic review. Photodiagnosis Photodyn Ther 2023; 42:103334. [PMID: 36764640 DOI: 10.1016/j.pdpdt.2023.103334] [Citation(s) in RCA: 3] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/13/2022] [Revised: 01/25/2023] [Accepted: 02/07/2023] [Indexed: 02/11/2023]
Abstract
Optical coherence tomography (OCT) is a non-invasive method that provides the opportunity to examine tissues by taking cross-sectional images. OCT is increasingly being used to evaluate anterior segment (AS) pathologies. Swept-source (SS) OCT allows greater penetration and achieves better visualization of the internal configuration of AS tissues due to the longer wavelength employed and high scan speeds. We reviewed the utilization of AS SS-OCT in various conditions including glaucoma, ocular surface pathologies, iris tumors, refractive surgery, cataract surgery, and scleral diseases. A systematic literature search was carried out on PubMed, Scopus, and Web of Science databases between January 1, 2008, and September 1, 2022 using the following keywords: AS SS-OCT; dry eye and SS-OCT; ocular surface and SS-OCT; cornea and SS-OCT; dystrophy and SS-OCT; glaucoma and SS-OCT; ocular surface tumors and SS-OCT; conjunctival tumors and SS-OCT; refractive surgery and SS-OCT; cataract and SS-OCT; biometry and SS-OCT; sclera and SS-OCT; iris and SS-OCT; ciliary body and SS-OCT; artificial intelligence and SS-OCT. A total of 221 studies were included in this review. Review of the existing literature shows that SS-OCT offers several advantages in the diagnosis of AS diseases. Exclusive features of SS-OCT including rapid scanning, deeper tissue penetration, and better image quality help improve our understanding of various AS pathologies.
Collapse
Affiliation(s)
- Ibadulla Mirzayev
- Department of Ophthalmology, Ankara University Faculty of Medicine, Ankara, Turkey; Halil Şıvgın Çubuk State Hospital, Ophthalmology Clinic, Ankara, Turkey
| | - Ahmet Kaan Gündüz
- Department of Ophthalmology, Ankara University Faculty of Medicine, Ankara, Turkey; Private Eye Clinic, Ankara, Turkey.
| | | | - Ömür Özlenen Gündüz
- Department of Ophthalmology, Ankara University Faculty of Medicine, Ankara, Turkey
| |
Collapse
|
5
|
Muacevic A, Adler JR. A Study Linking Axial Length, Corneal Curvature, and Eye Axis With Demographic Characteristics in the Emmetropic Eyes of Bangladeshi People. Cureus 2022; 14:e29925. [PMID: 36225244 PMCID: PMC9536359 DOI: 10.7759/cureus.29925] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 10/04/2022] [Indexed: 11/05/2022] Open
Abstract
Background Axial length (AL) and corneal curvature (CC) are one of the furthest critical parameters for optometry and oculoplastic surgery. These two variables are crucial in biometry for accurately measuring the power of the intraocular lens in cataract surgery. This research aimed to determine the association linking axial length and corneal curvature with demographic characteristics in emmetropic eyes of Bangladeshi people. Methods This descriptive cross-sectional research was carried out among 200 emmetropic eyes of Bangladeshi people attending the Department of Ophthalmology at Rajshahi Medical College, Bangladesh, with different eye conditions, between July 2017 and June 2018. Data was gathered by conducting person-to-person interviews, checking visual activity using the Snellen chart, and measuring corneal curvature using an auto-keratometer and axial eyeball length using A-scan ultrasonography. Results A total of 200 attendances were studied, 90 males and 110 females. All were emmetropic. The age range was 21-52 years, and the highest contributors were in the 21-30-year age group. The association between right axial length and right corneal curvature shows a negative relation among both sexes. It was -0.61 (β-coefficient (β-coff)), and highly significant in females at -0.89 (β-coff). Additionally, the association between left axial length and left corneal curvature shows a negative relation of -0.65 (β-coff), which was again highly significant in females at -0.87 (β-coff). Both were not significant in males. There was no significant association linking axial length and eye axis in both sexes. The multivariate regression model was used to assess the p-value, and the regression model was adjusted by age. Conclusion Optical parametric measurement is a noninvasive diagnostic and assessment tool that might help in the actual measurement of intraocular lens implantation in cataract surgery and may also provide supplementary information to the researcher domain.
Collapse
|
6
|
Detection of Anterior Hyaloid Membrane Detachment Using Deep-Range Anterior Segment Optical Coherence Tomography. J Clin Med 2022; 11:jcm11113057. [PMID: 35683445 PMCID: PMC9181063 DOI: 10.3390/jcm11113057] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/19/2022] [Revised: 04/26/2022] [Accepted: 05/27/2022] [Indexed: 02/01/2023] Open
Abstract
The visibility of anterior hyaloid membrane (AHM) and Berger’s space in phakic eyes was investigated. In 624 eyes of 624 patients, the retrolental space was scanned with the deep-range anterior segment optical coherence tomography (AS-OCT, CASIA2, Tomey). Subgroup analysis was conducted in 223 eyes undergoing cataract surgery. The logistic regression analysis using the backward-elimination method was performed to evaluate the influence of various factors on the visibility of AHM (dependent variable). Explanatory variables included age, gender, axial length, corneal power, corneal cylinder, and the Co III gradings. Intrarater repeatability for AHM visibility was excellent with the prevalence-adjusted bias-adjusted kappa (κ coefficient) of 0.90. AHM was observed in 43 eyes (6.9%). The patients with visible AHM (68.1 ± 8.8 years) were significantly older than those without visible AHM (52.6 ± 25.6 years) (p < 0.001). The logistic regression analysis in the cataract surgery subgroup revealed that axial length (p = 0.030) and corneal power (p = 0.043) were significantly associated with AHM visibility. The mean absolute refractive error from target was significantly larger in eyes with visible AHM (0.670 ± 0.384 D) than with invisible AHM (0.494 ± 0.412 D) (p = 0.037). The postoperative refractive prediction was less accurate in eyes with visible AHM, but no significant tendency existed in terms of myopic or hyperopic shifts.
Collapse
|
7
|
Affiliation(s)
- Roy Quinlan
- Biomedical Sciences, Department of Biosciences, The University of Durham, Upper Mountjoy Science Site, Durham, DH1 3LE, UK.
| | - Frank Giblin
- Biomedical Sciences Emeritus, Eye Research Institute, Oakland University, Rochester, MI, 48309, USA.
| |
Collapse
|
8
|
Wang Z, Meng Y, Wang Z, Hao L, Rashidi V, Sun H, Zhang J, Liu X, Duan X, Jiao Z, Qie S, Yan Z. Crystalline lens thickness change is associated with axial length elongation and myopia progression in orthokeratology. Cont Lens Anterior Eye 2021; 45:101534. [PMID: 34772627 DOI: 10.1016/j.clae.2021.101534] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/06/2021] [Revised: 10/23/2021] [Accepted: 11/01/2021] [Indexed: 11/03/2022]
Abstract
AIMS Considering individual variability in regards to the effects of orthokeratology (ortho-k) on myopia progression and controversies regarding the precise underlying mechanism, the aim of this study was to investigate several ocular measurements associated with axial length (AL) growth in children wearing ortho-k lenses. METHODS In this retrospective chart review, medical records of 53 Chinese children who wore ortho-k lenses over the course of 12 months were reviewed. Baseline variables included age at initiation of ortho-k wear, refractive error (spherical equivalent, SE), central corneal thickness (CCT), and flat and steep keratometry of corneal principal meridians. The change of anterior chamber depth (ACD) and the change of crystalline lens thickness (CLT) between baseline and the 12-month follow-up were also analyzed. The contributions of all analyzed variables to AL change were assessed using univariate and multivariate regression analyses. RESULTS Initially, the results of paired t-test showed that CLT and AL were significantly increased after 12 months of ortho-k wear compared with that at baseline (P = 0.001 and < 0.001). The ACD did not change significantly after 12 months compared with that at baseline (P = 0.491). Subsequently, univariate analyses showed that a reduced rate of AL elongation was found in children who were older age at initiation of ortho-k wear (P = 0.028), had greater SE (higher degree of myopia) at baseline (p = 0.006), had thicker CCT at baseline (P = 0.04), and had greater increase of CLT (P = 0.001) in 12 months. At last, only greater SE (higher degree of myopia) and greater increase of CLT were associated with smaller increases of AL in multivariable analyses, (P = 0.003 and 0.001). CONCLUSIONS Both CLT and AL were significantly increased in children with overnight ortho-k wear after 12 months of follow-up. Greater baseline SE and greater increase of CLT were associated with less increase in AL during ortho-k wear in children with myopia.
Collapse
Affiliation(s)
- Zengying Wang
- The Department of Ophthalmology, The Third Hospital of Hebei Medical University, 139 Ziqiang Road, Shijiazhuang, Hebei Province 050000, China
| | - Yifei Meng
- The Department of Ophthalmology, The Third Hospital of Hebei Medical University, 139 Ziqiang Road, Shijiazhuang, Hebei Province 050000, China
| | - Zuocheng Wang
- The Architecture of Hebei University, 13 Chaoyang West Street, Zhangjiagkou, Hebei Province, China
| | - Lili Hao
- The Fourth Hospital of Zhangjiakou, Hebei Province, China
| | - Vania Rashidi
- University of South Florida Morsani College of Medicine, Tampa, FL 33612, USA
| | - Haiyan Sun
- The Department of Ophthalmology, The Third Hospital of Hebei Medical University, 139 Ziqiang Road, Shijiazhuang, Hebei Province 050000, China
| | - Jun Zhang
- The Department of Ophthalmology, The Third Hospital of Hebei Medical University, 139 Ziqiang Road, Shijiazhuang, Hebei Province 050000, China
| | - Xiaokun Liu
- The Department of Ophthalmology, The Third Hospital of Hebei Medical University, 139 Ziqiang Road, Shijiazhuang, Hebei Province 050000, China
| | - Xuemin Duan
- The Department of Ophthalmology, The Third Hospital of Hebei Medical University, 139 Ziqiang Road, Shijiazhuang, Hebei Province 050000, China
| | - Zhaocai Jiao
- The Department of Ophthalmology, The Third Hospital of Hebei Medical University, 139 Ziqiang Road, Shijiazhuang, Hebei Province 050000, China
| | - Sufang Qie
- The Department of Ophthalmology, The Third Hospital of Hebei Medical University, 139 Ziqiang Road, Shijiazhuang, Hebei Province 050000, China
| | - Zhipeng Yan
- The Department of Ophthalmology, The Third Hospital of Hebei Medical University, 139 Ziqiang Road, Shijiazhuang, Hebei Province 050000, China.
| |
Collapse
|
9
|
Mitsukawa T, Suzuki Y, Momota Y, Suzuki S, Yamada M. Effects of 0.01% Atropine Instillation Assessed Using Swept-Source Anterior Segment Optical Coherence Tomography. J Clin Med 2021; 10:jcm10194384. [PMID: 34640402 PMCID: PMC8509630 DOI: 10.3390/jcm10194384] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/01/2021] [Revised: 09/22/2021] [Accepted: 09/23/2021] [Indexed: 01/16/2023] Open
Abstract
In this paper, we assessed the short-term effects of 0.01% atropine eye drops on anterior segment parameters by performing ocular biometry using a swept-source anterior segment optical coherence tomography system (AS-OCT). We recruited 17 healthy volunteers (10 men and 7 women aged 24–35 years) with no history of eye disease. Participants without accommodative demand demonstrated significant mydriasis 1 h after the atropine instillation (4.58 ± 0.77 to 5.41 ± 0.83 mm). Pupil diameters with a 5 diopter (D) accommodative stimulus at 1 h (4.70 ± 1.13 mm) and 24 h (4.05 ± 1.06 mm) after atropine instillation were significantly larger than those at baseline (3.71 ± 0.84 mm). Barring pupil diameter, no other biometric parameters significantly changed at any point in time after atropine instillation without accommodative demand. However, with an accommodative stimulus, anterior chamber depth (ACD) at 1 h and posterior curvature of the lens at 1 and 24 h were both significantly larger than those before atropine instillation. Using AS-OCT, we detected a slight decrease in the accommodation response of ocular biometric components evoked by 0.01% atropine instillation. Morphologically, our measurements suggested a change in the ACD and horizontal radius of the lens’ posterior surface curvatures due to the subtle reduction of accommodation.
Collapse
Affiliation(s)
| | - Yumi Suzuki
- Correspondence: ; Tel.: +81-422-47-5511; Fax: +81-422-46-9309
| | | | | | | |
Collapse
|
10
|
Quantitative analysis of internal components of the human crystalline lens during accommodation in adults. Sci Rep 2021; 11:6688. [PMID: 33758264 PMCID: PMC7987977 DOI: 10.1038/s41598-021-86007-6] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/06/2020] [Accepted: 03/08/2021] [Indexed: 12/23/2022] Open
Abstract
To quantitatively analyze changes in the inner components of the human crystalline lens during accommodation in adults. Eyes of 23 subjects were sequentially examined using CASIA2 Optical Coherence Tomography under 0D, - 3D and - 6D accommodation states. The anterior chamber depth (ACD), anterior and posterior crystalline lens radius of the curvature (ALRC and PLRC) were obtained using built-in software. The lens thickness (LT), lenticular nucleus thickness (NT), anterior cortex thickness (ACT), posterior cortex thickness (PCT), anterior and posterior lenticular nucleus radius of the curvature (ANRC and PNRC), anterior and posterior lenticular nucleus vertex (ANV and PNV) were quantified manually with the Image-pro plus software. During accommodation, the ACD became significantly shallower and LT significantly increased. For changes in the lens, the ALRC decreased by an average magnitude (related to accommodative stimuli) 0.44 mm/D, and PLRC decreased 0.09 mm/D. There was no difference for the ACT and PCT in different accommodation states. For lenticular nucleus response, NT increased on average by 30 μm/D. Both the ANRC and PNRC decreased on average by 212 μm/D and 115 μm/D respectively. The ANV moved forward on average by 0.07 mm under - 3D accommodative stimuli and 0.16 mm for - 6D. However, there was no statistically significant difference between different accommodation states in the PNV movement. Under accommodation stimulation, lens thickness changed mainly due to the lenticular nucleus, but not the cortex. For the lenticular nucleus, both the ANRC and PNRC decreased and ANRC changed the most. The anterior surface of the nucleus moved forward while the posterior surface of the nucleus moved backward but only slightly.
Collapse
|
11
|
Dai C, Liu M, Lv X, Li B. Subtle changes of the crystalline lens after cycloplegia: a retrospective study. BMC Ophthalmol 2021; 21:124. [PMID: 33676428 PMCID: PMC7937324 DOI: 10.1186/s12886-021-01884-9] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/16/2020] [Accepted: 02/25/2021] [Indexed: 12/19/2022] Open
Abstract
BACKGROUND The purpose of this study was to evaluate the shape of the crystalline lens in terms of biometry and diopters before and after cycloplegia using the CASIA2 swept-source (SS) optical coherence tomography (OCT) system on the anterior segment. METHODS This was a retrospective study. Children and adolescents (26 males and 29 females, aged 4-21 years) with simple ametropia were selected for optometry and CASIA2 imaging at 2 separate visits before and after cycloplegia. Diopter values were derived from the spherical power (S) obtained by optometry. Biometric parameters of the crystalline lens, including the anterior chamber depth (ACD), anterior and posterior curvature of the lens (ACL and PCL), lens thickness (LTH), lens decentration (LD), lens tilt (LT), and equivalent diameter of the lens (LED), were measured by the CASIA2 system. The differences in these parameters after compared with before cycloplegia were determined, and their relationships were analyzed. RESULTS Fifty-five participants (106 eyes) were initially enrolled. There was a significant difference (P < 0.05) in the S (t=-7.026, P < 0.001), ACD (t=-8.796, P < 0.001), ACL (t=-13.263, P < 0.001) and LTH (t = 7.363, P < 0.001) after compared with before cycloplegia. The change in the PCL (t = 1.557, P = 0.122), LD (t = 0.876, P = 0.383), LT (t = 0.440, P = 0.661) and LED (t=-0.351, P = 0.726) was not statistically significant (P > 0.05). There was a significant (P < 0.05) correlation of the change in the S with that in the ACL (r = 0.466, P < 0.001), LTH (r=-0.592, P < 0.001), and LED (r = 0.223, P = 0.021) but not the PCL (r = 0.19, P = 0.051), LD (r=-0.048, P = 0.0628) or LT (r=-0.022, P = 0.822). Furthermore, the change in the ACD was closely related to the change in crystalline morphology. However, in children and adolescents, we found that the change in crystalline morphology was unrelated to age. CONCLUSIONS Changes in lens morphology after compared with before cycloplegia are mainly related to the ACL and LTH, but there is no difference in the PCL, LD, LT, or LED. In the adolescent population, change in the S is related to change in the ACL, LED and LTH. However, age is unrelated to the shape and tendency of the crystalline lens. Further research is required to determine whether the same conclusion applies to different age groups and different refractive states (myopia, hyperopia, emmetropia) .
Collapse
Affiliation(s)
- Cheng Dai
- School of Basic Medicine, North Sichuan Medical College, Sichuan Province, 637000, Nanchong, China.,Department of Ophthalmology, Affiliated Hospital of North Sichuan Medical College, Sichuan Province, 637000, Nanchong, China
| | - Meng Liu
- School of Basic Medicine, North Sichuan Medical College, Sichuan Province, 637000, Nanchong, China
| | - Xiaodong Lv
- Department of Clinical Medicine, North Sichuan Medical College, Sichuan Province, 637000, Nanchong, China
| | - Binzhong Li
- School of Basic Medicine, North Sichuan Medical College, Sichuan Province, 637000, Nanchong, China.
| |
Collapse
|
12
|
Age-dependent changes in visual sensitivity induced by moving fixation points in adduction and abduction using imo perimetry. Sci Rep 2020; 10:21175. [PMID: 33273620 PMCID: PMC7713232 DOI: 10.1038/s41598-020-78147-y] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/15/2020] [Accepted: 11/12/2020] [Indexed: 11/17/2022] Open
Abstract
Visual field (VF) testing has usually been performed with the central gaze as a fixed point. Recent publications indicated optic nerve head deformations induced by optic nerve traction force can promote the progression of optic neuropathies, including glaucoma. We generated a new static test protocol that adds 6° adduction and abduction to gaze position (fixation points) movement. The aim of this study was to investigate both whether quantifying VF sensitivities at lateral horizontal gaze positions is feasible and whether horizontal gaze positions change sensitivities differently in subjects of different ages. Healthy adult eyes from 29 younger (≤ 45 years) and 28 elderly (> 45 years) eyes were examined in this cross-sectional study. After VF testing with central gaze as a fixation point using 24 plus (1) imo static perimetry, subjects underwent VF testing with 6° adduction and 6° abduction as fixation points. The average mean sensitivities with central gaze, adduction, and abduction were 29.9 ± 1.0, 29.9 ± 1.3, and 30.0 ± 1.2 decibels (dB) in younger subjects and 27.7 ± 1.2, 27.5 ± 1.7, and 28.1 ± 1.3 dB in elderly subjects, respectively. Visual sensitivity in young healthy subjects was similar among the three fixation points, whereas visual sensitivity in elderly healthy subjects was significantly better with abduction as a fixation point than with central gaze and adduction (both p < 0.05). We expect this test protocol to contribute to our understanding of visual function during horizontal eye gaze movement in various eye diseases.
Collapse
|
13
|
Li X, Chang P, Li Z, Qian S, Zhu Z, Wang Q, Yun-E Z. Agreement between anterior segment parameters obtained by a new ultrasound biomicroscopy and a swept-source fourier-domain anterior segment optical coherence tomography. Expert Rev Med Devices 2020; 17:1333-1340. [PMID: 33196325 DOI: 10.1080/17434440.2020.1848541] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/19/2023]
Abstract
Purpose: To evaluate the agreement between anew UBM and an SS-OCT. Methods: The scans of the right eye of each volunteer were obtained using the two devices. Data were fitted and recorded including: central corneal thickness (CCT), aqueous depth (AQD) (the distance from endothelium to lens), angle-to-angle distance (ATA), lens thickness (LT), diameter of the lens in the horizontal direction (LDiaangle: distance between the sharp angles on both sides of the lens, LDiaarc: distance between the vertex of the circular arcs on both sides of the lens), anterior and posterior corneal radius (Rf and Rb). Results: 25 eyes were included in this study. It could be seen that the differences in CCT, LDiaangle, Rf measured by the two instruments were not statistically significant. Bland-Altman analysis plots of CCT, LDiaangle and Rf showed mean differences of 0.2 µm, 0.01mm and 0.0mm for the 2 devices, respectively. Conclusion: The values of CCT, LDiaangle and Rf obtained via two instruments were not clinically interchangeable and the AQD, ATA, LT, and Rb have poor agreement affected by accommodation. We can estimate the real lens diameter by subtracting 0.61 ± 0.43mm when the lens diameter can only be simulated with SS-OCT.
Collapse
Affiliation(s)
- Xiuyuan Li
- Eye Hospital and School of Ophthalmology and Optometry, Wenzhou Medical University , Wenzhou, Zhejiang, China.,National Clinical Research Center for Ocular Diseases , Wenzhou, Zhejiang, China
| | - Pingjun Chang
- Eye Hospital and School of Ophthalmology and Optometry, Wenzhou Medical University , Wenzhou, Zhejiang, China.,National Clinical Research Center for Ocular Diseases , Wenzhou, Zhejiang, China
| | - Zhangliang Li
- Eye Hospital and School of Ophthalmology and Optometry, Wenzhou Medical University , Wenzhou, Zhejiang, China.,National Clinical Research Center for Ocular Diseases , Wenzhou, Zhejiang, China
| | - Shuyi Qian
- Eye Hospital and School of Ophthalmology and Optometry, Wenzhou Medical University , Wenzhou, Zhejiang, China.,National Clinical Research Center for Ocular Diseases , Wenzhou, Zhejiang, China
| | - Zehui Zhu
- Eye Hospital and School of Ophthalmology and Optometry, Wenzhou Medical University , Wenzhou, Zhejiang, China.,National Clinical Research Center for Ocular Diseases , Wenzhou, Zhejiang, China
| | - Qianwei Wang
- Eye Hospital and School of Ophthalmology and Optometry, Wenzhou Medical University , Wenzhou, Zhejiang, China.,National Clinical Research Center for Ocular Diseases , Wenzhou, Zhejiang, China
| | - Zhao Yun-E
- Eye Hospital and School of Ophthalmology and Optometry, Wenzhou Medical University , Wenzhou, Zhejiang, China.,National Clinical Research Center for Ocular Diseases , Wenzhou, Zhejiang, China
| |
Collapse
|
14
|
Comparison of the Stability of Two Intraocular Lenses in Primary Angle-Closure Glaucoma after Phacoemulsification. J Ophthalmol 2020. [DOI: 10.1155/2020/9284245] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/18/2022] Open
Abstract
Objective. To observe the stability of intraocular lenses (IOLs) in primary angle-closure glaucoma by ultralong scan depth spectral-domain optical coherence tomography (UL-OCT) after phacoemulsification. Methods. A prospective, randomized study. 73 patients (82 eyes) with primary closed-angle glaucoma and age-related cataract were included in the study. 42 eyes were implanted with ZCB00, while 40 eyes were implanted with Softec HD after phacoemulsification. The tilt, decentration, and space between IOL and posterior capsule (IOL-PC space) were analyzed using UL-OCT at 1 week, 1 month, and 3 months after surgery. The intergroup difference was compared with the paired t-test. Result. The difference of decentration and tilt was not statistically significant (both
) both in the horizontal and vertical positions at 1 week, 1 month, and 3 months postoperatively. The horizontal IOL-PC space is 0.111 ± 0.091 mm2, 0.044 ± 0.066 mm2, and 0.055 ± 0.055 mm2 in the Softec HD group and 0.458 ± 0.488 mm2, 0.497 ± 0.363 mm2, and 0.492 ± 0.441 mm2 in the ZCB00 group. The vertical IOL-PC space is 0.102 ± 0.061 mm2, 0.037 ± 0.052 mm2, and 0.053 ± 0.079 mm2 in the Softec HD group and 0.692 ± 0.815 mm2, 0.510 ± 0.415 mm2, and 0.691 ± 0.635 mm2 in the ZCB00 group. The difference was statistically significant (
) both in the horizontal and vertical positions except for the first week on the horizon. The Softec HD group is smaller than the ZCB00 group. Conclusion. There is no difference in the stability of the IOL although the IOL-PC space is different. The thickness of IOL may affect the IOL-PC space.
Collapse
|
15
|
Ruan X, Liu Z, Luo L, Liu Y. The Structure of the Lens and Its Associations with the Visual Quality. BMJ Open Ophthalmol 2020; 5:e000459. [PMID: 33024825 PMCID: PMC7511618 DOI: 10.1136/bmjophth-2020-000459] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/22/2020] [Revised: 08/22/2020] [Accepted: 08/24/2020] [Indexed: 12/30/2022] Open
Abstract
In humans, the lens is the organ with the ability to change morphology and refractive power, designated as accommodation, to focus light from various distances and obtain clear retinal image. The accommodative ability of the lens depends on its structure and biological parameters. The lens grows throughout the life, forming specific lens sutures and a unique gradient refractive index, and possesses regenerative ability under certain circumstances. Minimally invasive lens surgery that preserves endogenous lens epithelial stem/progenitor cells (LECs) can achieve functional lens regeneration in humans. The lens is the main source of intraocular aberration, especially intraocular higher-order aberrations (IHOAs) which is found to be binocularly symmetrical in phakic eyes. There is a compensation mechanism between corneal aberrations and lens aberrations. Therefore, the structure and the biological parameters of the lens, the binocular relationship of the lens and the correlation between the lens and cornea affect visual quality. This paper summarises the above findings and their current and potential applications in refractive surgeries, providing a comprehensive understanding of the lens as a strong determinant of visual quality in the optical system.
Collapse
Affiliation(s)
- Xiaoting Ruan
- State Key Laboratory of Ophthalmology, Sun Yat-Sen University Zhongshan Ophthalmic Center, Guangzhou, China
| | - Zhenzhen Liu
- State Key Laboratory of Ophthalmology, Sun Yat-Sen University Zhongshan Ophthalmic Center, Guangzhou, China
| | - Lixia Luo
- State Key Laboratory of Ophthalmology, Sun Yat-Sen University Zhongshan Ophthalmic Center, Guangzhou, China
| | - Yizhi Liu
- State Key Laboratory of Ophthalmology, Sun Yat-Sen University Zhongshan Ophthalmic Center, Guangzhou, China
| |
Collapse
|
16
|
Mitsukawa T, Suzuki Y, Momota Y, Suzuki S, Yamada M. Anterior Segment Biometry During Accommodation and Effects of Cycloplegics by Swept-Source Optical Coherence Tomography. Clin Ophthalmol 2020; 14:1237-1243. [PMID: 32440090 PMCID: PMC7213076 DOI: 10.2147/opth.s252474] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/04/2020] [Accepted: 04/21/2020] [Indexed: 11/23/2022] Open
Abstract
Purpose We analyzed changes in the crystalline lens during accommodation and the effects of cycloplegics by swept-source anterior-segment optical coherence tomography (AS-OCT). Materials and Methods Twenty healthy volunteers (7 males and 13 females, aged 22–34 years), with no history of eye disease except for refractive errors, were recruited. Biometric parameters, including anterior chamber depth (ACD), lens thickness (LT), and anterior and posterior curvature of the lens (ACL and PCL), were measured using AS-OCT (CASIA2). The measurements were performed with or without an accommodative demand of 5.0 diopters (D). The same tests were repeated following the topical administration of 1% cyclopentolate or a compounding agent comprising 0.5% tropicamide and 0.5% phenylephrine. Results The AS-OCT system was capable of simultaneous visualization of all optical components of the anterior segment in a single frame. ACD, LAC, and LPC decreased and LT increased significantly during 5.0 D accommodative stimulation in both eyes. Both cyclopentolate and tropicamide/phenylephrine eyedrops led to deeper ACD, thinner LT, and flatter LAC. There were no significant differences in all lens parameters despite having 5.0 D accommodative stimulation in both eyes with cycloplegia. Conclusion Our results suggest that both tropicamide/phenylephrine and cyclopentolate eyedrops have enough cycloplegic effects in young adults.
Collapse
Affiliation(s)
- Tadahiro Mitsukawa
- Department of Ophthalmology, Kyorin University School of Medicine, Mitaka, Tokyo 181-8611, Japan
| | - Yumi Suzuki
- Department of Ophthalmology, Kyorin University School of Medicine, Mitaka, Tokyo 181-8611, Japan
| | - Yosuke Momota
- Department of Ophthalmology, Kyorin University School of Medicine, Mitaka, Tokyo 181-8611, Japan
| | - Shun Suzuki
- Department of Ophthalmology, Kyorin University School of Medicine, Mitaka, Tokyo 181-8611, Japan
| | - Masakazu Yamada
- Department of Ophthalmology, Kyorin University School of Medicine, Mitaka, Tokyo 181-8611, Japan
| |
Collapse
|