1
|
Schwartz G, Rana S, Jackson AR, Leñero C, Best TM, Kouroupis D, Travascio F. Human mesenchymal stem/stromal cell-derived extracellular vesicle transport in meniscus fibrocartilage. J Orthop Res 2025; 43:457-465. [PMID: 39396193 DOI: 10.1002/jor.25993] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/17/2024] [Revised: 09/08/2024] [Accepted: 09/29/2024] [Indexed: 10/14/2024]
Abstract
Extracellular vesicles (EVs) derived from endometrial-derived mesenchymal stem/stromal cells (eMSC) play a crucial role in tissue repair due to their immunomodulatory and reparative properties. Given these properties, eMSC EVs may offer potential benefits for meniscal repair. The meniscus, being partly vascularized, relies on diffusivity for solute trafficking. This study focuses on EVs transport properties characterization within fibrocartilage that remains unknown. Specifically, EVs were isolated from Crude and CD146+ eMSC populations. Green fluorescence-labeled EVs transport properties were investigated in three structurally distinct layers (core, femoral, and tibial surfaces) of porcine meniscus. Diffusivity was measured via custom fluorescence recovery after photobleaching (FRAP) technique. Light spectrometry was used to determine EVs solubility. Both Crude and CD146+ eMSC EVs exhibited high purity (>90% CD63CD9 marker expression) and an average diffusivity of 10.924 (±4.065) µm²/s. Importantly, no significant difference was observed between Crude and CD146+ eMSC EV diffusivity on the meniscal layer (p > 0.05). The mean partitioning coefficient was 0.2118 (±0.1321), with Crude EVs demonstrating significantly higher solubility than CD146+ EVs (p < 0.05). In conclusion, this study underscores the potential of both Crude and CD146+ eMSC EVs to traverse all layers of the meniscus, supporting their capacity to enhance delivery of orthobiologics for cartilaginous tissue healing.
Collapse
Affiliation(s)
- Gabi Schwartz
- Department of Biomedical Engineering, University of Miami, Coral Gables, USA
| | - Samir Rana
- Department of Kinesiology and Sports Sciences, University of Miami, Coral Gables, USA
| | - Alicia R Jackson
- Department of Biomedical Engineering, University of Miami, Coral Gables, USA
| | - Clarissa Leñero
- Department of Orthopedics, UHealth Sports Medicine Institute, Miller School of Medicine, University of Miami, Miami, USA
- Diabetes Research Institute & Cell Transplant Center, Miller School of Medicine, University of Miami, Miami, USA
| | - Thomas M Best
- Department of Biomedical Engineering, University of Miami, Coral Gables, USA
- Department of Orthopedics, UHealth Sports Medicine Institute, Miller School of Medicine, University of Miami, Miami, USA
| | - Dimitrios Kouroupis
- Department of Orthopedics, UHealth Sports Medicine Institute, Miller School of Medicine, University of Miami, Miami, USA
- Diabetes Research Institute & Cell Transplant Center, Miller School of Medicine, University of Miami, Miami, USA
| | - Francesco Travascio
- Department of Orthopedics, UHealth Sports Medicine Institute, Miller School of Medicine, University of Miami, Miami, USA
- Department of Mechanical and Aerospace Engineering, University of Miami, Coral Gables, USA
- Max Biedermann Institute for Biomechanics, Mount Sinai Medical Center, Miami Beach, USA
| |
Collapse
|
2
|
Wang S, Mueller D, Chen P, Pan G, Wilson M, Sun S, Chen Z, Lee T, Damon B, Hepfer RG, Hill C, Kern MJ, Pullen WM, Wu Y, Brockbank KGM, Yao H. Viable Vitreous Grafts of Whole Porcine Menisci for Transplant in the Knee and Temporomandibular Joints. Adv Healthc Mater 2024; 13:e2303706. [PMID: 38523366 PMCID: PMC11368656 DOI: 10.1002/adhm.202303706] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/25/2023] [Revised: 03/20/2024] [Indexed: 03/26/2024]
Abstract
The shortage of suitable donor meniscus grafts from the knee and temporomandibular joint (TMJ) impedes treatments for millions of patients. Vitrification offers a promising solution by transitioning these tissues into a vitreous state at cryogenic temperatures, protecting them from ice crystal damage using high concentrations of cryoprotectant agents (CPAs). However, vitrification's success is hindered for larger tissues (>3 mL) due to challenges in CPA penetration. Dense avascular meniscus tissues require extended CPA exposure for adequate penetration; however, prolonged exposure becomes cytotoxic. Balancing penetration and reducing cell toxicity is required. To overcome this hurdle, a simulation-based optimization approach is developed by combining computational modeling with microcomputed tomography (µCT) imaging to predict 3D CPA distributions within tissues over time accurately. This approach minimizes CPA exposure time, resulting in 85% viability in 4-mL meniscal specimens, 70% in 10-mL whole knee menisci, and 85% in 15-mL whole TMJ menisci (i.e., TMJ disc) post-vitrification, outperforming slow-freezing methods (20%-40%), in a pig model. The extracellular matrix (ECM) structure and biomechanical strength of vitreous tissues remain largely intact. Vitreous meniscus grafts demonstrate clinical-level viability (≥70%), closely resembling the material properties of native tissues, with long-term availability for transplantation. The enhanced vitrification technology opens new possibilities for other avascular grafts.
Collapse
Affiliation(s)
- Shangping Wang
- Department of Bioengineering, Clemson University, Clemson, SC, 29634, USA
| | - Dustin Mueller
- Department of Bioengineering, Clemson University, Clemson, SC, 29634, USA
- Department of Oral Health Sciences, Medical University of South Carolina, Charleston, SC, 29425, USA
| | - Peng Chen
- Department of Bioengineering, Clemson University, Clemson, SC, 29634, USA
| | - Ge Pan
- Department of Bioengineering, Clemson University, Clemson, SC, 29634, USA
| | - Marshall Wilson
- Department of Bioengineering, Clemson University, Clemson, SC, 29634, USA
| | - Shuchun Sun
- Department of Bioengineering, Clemson University, Clemson, SC, 29634, USA
| | - Zhenzhen Chen
- Tissue Testing Technologies LLC, North Charleston, SC, 29406, USA
| | - Thomas Lee
- Department of Bioengineering, Clemson University, Clemson, SC, 29634, USA
| | - Brooke Damon
- Department of Bioengineering, Clemson University, Clemson, SC, 29634, USA
| | - R Glenn Hepfer
- Department of Oral Health Sciences, Medical University of South Carolina, Charleston, SC, 29425, USA
| | - Cherice Hill
- Department of Bioengineering, Clemson University, Clemson, SC, 29634, USA
- Department of Oral Health Sciences, Medical University of South Carolina, Charleston, SC, 29425, USA
| | - Michael J Kern
- Department of Regenerative Medicine and Cell Biology, Medical University of South Carolina, Charleston, SC, 29425, USA
| | - William M Pullen
- Department of Orthopaedics, Medical University of South Carolina, Charleston, SC, 29425, USA
| | - Yongren Wu
- Department of Bioengineering, Clemson University, Clemson, SC, 29634, USA
- Department of Orthopaedics, Medical University of South Carolina, Charleston, SC, 29425, USA
| | - Kelvin G M Brockbank
- Department of Bioengineering, Clemson University, Clemson, SC, 29634, USA
- Tissue Testing Technologies LLC, North Charleston, SC, 29406, USA
| | - Hai Yao
- Department of Bioengineering, Clemson University, Clemson, SC, 29634, USA
- Department of Oral Health Sciences, Medical University of South Carolina, Charleston, SC, 29425, USA
- Department of Regenerative Medicine and Cell Biology, Medical University of South Carolina, Charleston, SC, 29425, USA
- Department of Orthopaedics, Medical University of South Carolina, Charleston, SC, 29425, USA
| |
Collapse
|
3
|
Schwartz G, Best TM, Chen CB, Travascio F, Jackson AR. Assessing the role of surface layer and molecular probe size in diffusion within meniscus tissue. PLoS One 2024; 19:e0301432. [PMID: 38626169 PMCID: PMC11020779 DOI: 10.1371/journal.pone.0301432] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/15/2023] [Accepted: 03/15/2024] [Indexed: 04/18/2024] Open
Abstract
Diffusion within extracellular matrix is essential to deliver nutrients and larger metabolites to the avascular region of the meniscus. It is well known that both structure and composition of the meniscus vary across its regions; therefore, it is crucial to fully understand how the heterogenous meniscal architecture affects its diffusive properties. The objective of this study was to investigate the effect of meniscal region (core tissue, femoral, and tibial surface layers) and molecular weight on the diffusivity of several molecules in porcine meniscus. Tissue samples were harvested from the central area of porcine lateral menisci. Diffusivity of fluorescein (MW 332 Da) and three fluorescence-labeled dextrans (MW 3k, 40k, and 150k Da) was measured via fluorescence recovery after photobleaching. Diffusivity was affected by molecular size, decreasing as the Stokes' radius of the solute increased. There was no significant effect of meniscal region on diffusivity for fluorescein, 3k and 40k dextrans (p>0.05). However, region did significantly affect the diffusivity of 150k Dextran, with that in the tibial surface layer being larger than in the core region (p = 0.001). Our findings contribute novel knowledge concerning the transport properties of the meniscus fibrocartilage. This data can be used to advance the understanding of tissue pathophysiology and explore effective approaches for tissue restoration.
Collapse
Affiliation(s)
- Gabi Schwartz
- Department of Biomedical Engineering, University of Miami, Coral Gables, FL, United States of America
| | - Thomas M. Best
- Department of Orthopaedic Surgery, University of Miami, Miami, FL, United States of America
- UHealth Sports Medicine Institute, Coral Gables, FL, United States of America
| | - Cheng-Bang Chen
- Department of Industrial and Systems Engineering, University of Miami, Coral Gables, FL, United States of America
| | - Francesco Travascio
- Department of Orthopaedic Surgery, University of Miami, Miami, FL, United States of America
- Department of Mechanical and Aerospace Engineering, University of Miami, Coral Gables, FL, United States of America
- Max Biedermann Institute for Biomechanics at Mount Sinai Medical Center, Miami Beach, FL, United States of America
| | - Alicia R. Jackson
- Department of Biomedical Engineering, University of Miami, Coral Gables, FL, United States of America
| |
Collapse
|
4
|
Dong F, Zhang P, Ma B, Bao G, Kang H. Effects of glucose concentration and oxygen partial pressure on the respiratory metabolism of sheep temporomandibular joint disc cells. Exp Ther Med 2023; 26:387. [PMID: 37456155 PMCID: PMC10347106 DOI: 10.3892/etm.2023.12086] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/10/2022] [Accepted: 06/02/2023] [Indexed: 07/18/2023] Open
Abstract
Temporomandibular joint (TMJ) disc degeneration is a common disease characterized by a decrease in metabolic function. The present study aimed to investigate the pathogenesis of TMJ disc degeneration by analyzing the effects of oxygen and glucose concentrations on metabolism in a simulated TMJ disc cell growth environment. Cell samples were divided into 10 groups and cultured in different nutritional environments, including 21 and 2% O2 partial pressures and various glucose concentrations (0, 0.5, 3, 5.5 and 22.5 mmol/l). Cell proliferation, extracellular matrix content, mitochondrial function, and cell metabolism were subsequently analyzed. The results demonstrated that hypoxia and a low glucose concentration inhibited cell growth, and low glucose concentration inhibited extracellular matrix synthesis and adenosine 5'-monophosphate-activated protein kinase expression. Hypoxic conditions also induced a compensatory increase in the number of mitochondria, whereas mitochondrial deformation and swelling were observed in the absence of glucose. According to this study, the primary metabolic pathway of TMJ disc cells is glycolysis. It was concluded that hypoxic conditions and normal glucose concentrations are needed for the growth of TMJ disc cells. Glucose is necessary to ensure cell survival, extracellular matrix synthesis and mitochondrial function. Glucose deficiency may be related to disc degeneration, aging and disease mechanisms.
Collapse
Affiliation(s)
- Fangrui Dong
- Key Laboratory of Dental Maxillofacial Reconstruction and Biological Intelligence Manufacturing, School of Stomatology, Lanzhou University, Lanzhou, Gansu 730000, P.R. China
| | - Pengfei Zhang
- Key Laboratory of Dental Maxillofacial Reconstruction and Biological Intelligence Manufacturing, School of Stomatology, Lanzhou University, Lanzhou, Gansu 730000, P.R. China
| | - Bin Ma
- Key Laboratory of Stomatology of State Ethnic Affairs Commission, Northwest Minzu University, Lanzhou, Gansu 730030, P.R. China
| | - Guangjie Bao
- Key Laboratory of Stomatology of State Ethnic Affairs Commission, Northwest Minzu University, Lanzhou, Gansu 730030, P.R. China
| | - Hong Kang
- Key Laboratory of Dental Maxillofacial Reconstruction and Biological Intelligence Manufacturing, School of Stomatology, Lanzhou University, Lanzhou, Gansu 730000, P.R. China
| |
Collapse
|
5
|
Ren P, Chen P, Reeves RA, Buchweitz N, Niu H, Gong H, Mercuri J, Reitman CA, Yao H, Wu Y. Diffusivity of Human Cartilage Endplates in Healthy and Degenerated Intervertebral Disks. J Biomech Eng 2023; 145:071006. [PMID: 36752723 PMCID: PMC10159583 DOI: 10.1115/1.4056871] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/20/2022] [Revised: 01/29/2023] [Accepted: 02/05/2023] [Indexed: 02/09/2023]
Abstract
The cartilage endplates (CEPs) on the superior and inferior surfaces of the intervertebral disk (IVD), are the primary nutrient transport pathways between the disk and the vertebral body. Passive diffusion is responsible for transporting small nutrient and metabolite molecules through the avascular CEPs. The baseline solute diffusivities in healthy CEPs have been previously studied, however alterations in CEP diffusion associated with IVD degeneration remain unclear. This study aimed to quantitatively compare the solute diffusion in healthy and degenerated human CEPs using a fluorescence recovery after photobleaching (FRAP) approach. Seven healthy CEPs and 22 degenerated CEPs were collected from five fresh-frozen human cadaveric spines and 17 patients undergoing spine fusion surgery, respectively. The sodium fluorescein diffusivities in CEP radial and vertical directions were measured using the FRAP method. The CEP calcification level was evaluated by measuring the average X-ray attenuation. No difference was found in solute diffusivities between radial and axial directions in healthy and degenerated CEPs. Compared to healthy CEPs, the average solute diffusivity was 44% lower in degenerated CEPs (Healthy: 29.07 μm2/s (CI: 23.96-33.62 μm2/s); degenerated: 16.32 μm2/s (CI: 13.84-18.84 μm2/s), p < 0.001). The average solute diffusivity had an inverse relationship with the degree of CEP calcification as determined by the normalized X-ray attenuation values (ß = -22.19, R2 = 0.633; p < 0.001). This study suggests that solute diffusion through the disk and vertebral body interface is significantly hindered by CEP calcification, providing clues to help further understand the mechanism of IVD degeneration.
Collapse
Affiliation(s)
- Pengling Ren
- Department of Bioengineering, Clemson University, Clemson, SC 29425; Department of Orthopaedics and Physical Medicine, Medical University of South Carolina (MUSC), Charleston, SC 29425; Department of Radiology, Beijing Friendship Hospital, Capital Medical University, Beijing 100052, China; Key Laboratory for Biomechanics and Mechanobiology of Ministry of Education, School of Biological Science and Medical Engineering, Beihang University, Beijing 100191, China
| | - Peng Chen
- Department of Bioengineering, Clemson University, Clemson, SC 29425
| | - Russell A. Reeves
- Department of Radiology, Sidney Kimmel Medical College, Thomas Jefferson University, Philadelphia, PA 19107
| | - Nathan Buchweitz
- Department of Bioengineering, Clemson University, Clemson, SC 29425
| | - Haijun Niu
- Key Laboratory for Biomechanics and Mechanobiology of Ministry of Education, School of Biological Science and Medical Engineering, Beihang University, Beijing 100191, China
| | - He Gong
- Key Laboratory for Biomechanics and Mechanobiology of Ministry of Education, School of Biological Science and Medical Engineering, Beihang University, Beijing 100191, China
| | - Jeremy Mercuri
- Department of Bioengineering, Clemson University, Clemson, SC 29425
| | - Charles A. Reitman
- Department of Orthopaedics and Physical Medicine, Medical University of South Carolina (MUSC), Charleston, SC 29425
| | - Hai Yao
- Department of Bioengineering, Clemson University, Clemson, SC 29425; Department of Orthopaedics and Physical Medicine, Medical University of South Carolina (MUSC), Charleston, SC 29425
| | - Yongren Wu
- Department of Bioengineering, Clemson University, 68 President Street, MSC501, Clemson, SC 29425; Department of Orthopaedics and Physical Medicine, Medical University of South Carolina (MUSC), Charleston, SC 29425
| |
Collapse
|
6
|
Schwartz G, Morejon A, Best TM, Jackson AR, Travascio F. Strain-Dependent Diffusivity of Small and Large Molecules in Meniscus. J Biomech Eng 2022; 144:111010. [PMID: 35789377 PMCID: PMC9309715 DOI: 10.1115/1.4054931] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/18/2022] [Revised: 06/28/2022] [Indexed: 11/08/2022]
Abstract
Due to lack of full vascularization, the meniscus relies on diffusion through the extracellular matrix to deliver small (e.g., nutrients) and large (e.g., proteins) to resident cells. Under normal physiological conditions, the meniscus undergoes up to 20% compressive strains. While previous studies characterized solute diffusivity in the uncompressed meniscus, to date, little is known about the diffusive transport under physiological strain levels. This information is crucial to fully understand the pathophysiology of the meniscus. The objective of this study was to investigate strain-dependent diffusive properties of the meniscus fibrocartilage. Tissue samples were harvested from the central portion of porcine medial menisci and tested via fluorescence recovery after photobleaching to measure diffusivity of fluorescein (332 Da) and 40 K Da dextran (D40K) under 0%, 10%, and 20% compressive strain. Specifically, average diffusion coefficient and anisotropic ratio, defined as the ratio of the diffusion coefficient in the direction of the tissue collagen fibers to that orthogonal, were determined. For all the experimental conditions investigated, fluorescein diffusivity was statistically faster than that of D40K. Also, for both molecules, diffusion coefficients significantly decreased, up to ∼45%, as the strain increased. In contrast, the anisotropic ratios of both molecules were similar and not affected by the strain applied to the tissue. This suggests that compressive strains used in this study did not alter the diffusive pathways in the meniscus. Our findings provide new knowledge on the transport properties of the meniscus fibrocartilage that can be leveraged to further understand tissue pathophysiology and approaches to tissue restoration.
Collapse
Affiliation(s)
- Gabi Schwartz
- Department of Biomedical Engineering, University of Miami, Coral Gables, FL 33146
| | - Andy Morejon
- Department of Mechanical and Aerospace Engineering, University of Miami, Coral Gables, FL 33146
| | - Thomas M Best
- Department of Orthopaedic Surgery, University of Miami, Miami, FL 33136; Department of Biomedical Engineering, University of Miami, Coral Gables, FL 33146;UHealth Sports Medicine Institute, Coral Gables, FL 33146
| | - Alicia R Jackson
- Department of Biomedical Engineering, University of Miami, Coral Gables, FL 33146
| | - Francesco Travascio
- Department of Mechanical and Aerospace Engineering, University of Miami, Coral Gables, FL 33146; Department of Orthopaedic Surgery, University of Miami, Miami, FL 33136; Max Biedermann Institute for Biomechanics at Mount, Sinai Medical Center, Miami Beach, FL 33140
| |
Collapse
|
7
|
Chen P, Chen X, Hepfer RG, Damon BJ, Shi C, Yao JJ, Coombs MC, Kern MJ, Ye T, Yao H. A noninvasive fluorescence imaging-based platform measures 3D anisotropic extracellular diffusion. Nat Commun 2021; 12:1913. [PMID: 33772014 PMCID: PMC7997923 DOI: 10.1038/s41467-021-22221-0] [Citation(s) in RCA: 17] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/15/2020] [Accepted: 03/03/2021] [Indexed: 12/21/2022] Open
Abstract
Diffusion is a major molecular transport mechanism in biological systems. Quantifying direction-dependent (i.e., anisotropic) diffusion is vitally important to depicting how the three-dimensional (3D) tissue structure and composition affect the biochemical environment, and thus define tissue functions. However, a tool for noninvasively measuring the 3D anisotropic extracellular diffusion of biorelevant molecules is not yet available. Here, we present light-sheet imaging-based Fourier transform fluorescence recovery after photobleaching (LiFT-FRAP), which noninvasively determines 3D diffusion tensors of various biomolecules with diffusivities up to 51 µm2 s-1, reaching the physiological diffusivity range in most biological systems. Using cornea as an example, LiFT-FRAP reveals fundamental limitations of current invasive two-dimensional diffusion measurements, which have drawn controversial conclusions on extracellular diffusion in healthy and clinically treated tissues. Moreover, LiFT-FRAP demonstrates that tissue structural or compositional changes caused by diseases or scaffold fabrication yield direction-dependent diffusion changes. These results demonstrate LiFT-FRAP as a powerful platform technology for studying disease mechanisms, advancing clinical outcomes, and improving tissue engineering.
Collapse
Affiliation(s)
- Peng Chen
- Clemson-MUSC Joint Bioengineering Program, Department of Bioengineering, Clemson University, Clemson, SC, USA
| | - Xun Chen
- Clemson-MUSC Joint Bioengineering Program, Department of Bioengineering, Clemson University, Clemson, SC, USA
| | - R Glenn Hepfer
- Clemson-MUSC Joint Bioengineering Program, Department of Bioengineering, Clemson University, Clemson, SC, USA
- Department of Oral Health Sciences, Medical University of South Carolina, Charleston, SC, USA
| | - Brooke J Damon
- Clemson-MUSC Joint Bioengineering Program, Department of Bioengineering, Clemson University, Clemson, SC, USA
| | - Changcheng Shi
- Clemson-MUSC Joint Bioengineering Program, Department of Bioengineering, Clemson University, Clemson, SC, USA
- Ningbo Institute of Industrial Technology, Chinese Academy of Sciences, Ningbo, Zhejiang, China
| | - Jenny J Yao
- Department of Physics, Harvard University, Cambridge, MA, USA
| | - Matthew C Coombs
- Clemson-MUSC Joint Bioengineering Program, Department of Bioengineering, Clemson University, Clemson, SC, USA
- Department of Oral Health Sciences, Medical University of South Carolina, Charleston, SC, USA
| | - Michael J Kern
- Department of Regenerative Medicine and Cell Biology, Medical University of South Carolina, Charleston, SC, USA
| | - Tong Ye
- Clemson-MUSC Joint Bioengineering Program, Department of Bioengineering, Clemson University, Clemson, SC, USA.
- Department of Regenerative Medicine and Cell Biology, Medical University of South Carolina, Charleston, SC, USA.
| | - Hai Yao
- Clemson-MUSC Joint Bioengineering Program, Department of Bioengineering, Clemson University, Clemson, SC, USA.
- Department of Oral Health Sciences, Medical University of South Carolina, Charleston, SC, USA.
| |
Collapse
|
8
|
Hepfer RG, Chen P, Shi C, Rocha KM, Waring GO, Slate EH, Yao H. Depth- and direction-dependent changes in solute transport following cross-linking with riboflavin and UVA light in ex vivo porcine cornea. Exp Eye Res 2021; 205:108498. [PMID: 33600810 DOI: 10.1016/j.exer.2021.108498] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/15/2020] [Revised: 01/15/2021] [Accepted: 02/08/2021] [Indexed: 11/15/2022]
Abstract
Diffusion is an important mechanism of transport for nutrients and drugs throughout the avascular corneal stroma. The purpose of this study was to investigate the depth- and direction-dependent changes in stromal transport properties and their relationship to changes in collagen structure following ultraviolet A (UVA)-riboflavin induced corneal collagen cross-linking (CXL). After cross-linking in ex vivo porcine eyes, fluorescence recovery after photobleaching (FRAP) was performed to measure fluorescein diffusion in the nasal-temporal (NT) and anterior-posterior (AP) directions at corneal depths of 100, 200, and 300 μm. Second harmonic generation (SHG) imaging was also performed at these three corneal depths to quantify fiber alignment. For additional confirmation, an electrical conductivity method was employed to quantify ion permeability in the AP direction in corneal buttons and immunohistochemistry (IHC) was used to image collagen structure. Cross-linked corneas were compared to a control treatment that received the riboflavin solution without UVA light (SHAM). The results of FRAP revealed that fluorescein diffusivity decreased from 23.39 ± 11.60 μm2/s in the SHAM group to 19.87 ± 10.10 μm2/s in the CXL group. This change was dependent on depth and direction: the decrease was more pronounced in the 100 μm depth (P = 0.0005) and AP direction (P = 0.001) when compared to the effect in deeper locations and in the NT direction, respectively. Conductivity experiments confirmed a decrease in solute transport in the AP direction (P < 0.0001). FRAP also detected diffusional anisotropy in the porcine cornea: the fluorescein diffusivity in the NT direction was higher than the diffusivity in the AP direction. This anisotropy was increased following CXL treatment. Both SHG and IHC revealed a qualitative decrease in collagen crimping following CXL. Analysis of SHG images revealed an increase in coherency in the anterior 200 μm of CXL treated corneas when compared to SHAM treated corneas (P < 0.01). In conclusion, CXL results in a decrease in stromal solute transport, and this decrease is concentrated in the most anterior region and AP direction. Solute transport in the porcine cornea is anisotropic, and an increase in anisotropy with CXL may be explained by a decrease in collagen crimping.
Collapse
Affiliation(s)
- R Glenn Hepfer
- Clemson-MUSC Bioengineering Program, Department of Bioengineering, Clemson University, Charleston, SC, USA; Department of Oral Health Science, Medical University of South Carolina, Charleston, SC, USA
| | - Peng Chen
- Clemson-MUSC Bioengineering Program, Department of Bioengineering, Clemson University, Charleston, SC, USA
| | - Changcheng Shi
- Clemson-MUSC Bioengineering Program, Department of Bioengineering, Clemson University, Charleston, SC, USA
| | - Karolinne M Rocha
- Storm Eye Institute, Department of Ophthalmology, Medical University of South Carolina (MUSC), Charleston, SC, USA
| | | | - Elizabeth H Slate
- Department of Statistics, Florida State University, Tallahassee, FL, USA
| | - Hai Yao
- Clemson-MUSC Bioengineering Program, Department of Bioengineering, Clemson University, Charleston, SC, USA; Department of Oral Health Science, Medical University of South Carolina, Charleston, SC, USA.
| |
Collapse
|
9
|
Geiger AC, Smith CJ, Takanti N, Harmon DM, Carlsen MS, Simpson GJ. Anomalous Diffusion Characterization by Fourier Transform-FRAP with Patterned Illumination. Biophys J 2020; 119:737-748. [PMID: 32771078 DOI: 10.1016/j.bpj.2020.07.013] [Citation(s) in RCA: 12] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/13/2020] [Revised: 06/09/2020] [Accepted: 07/07/2020] [Indexed: 02/06/2023] Open
Abstract
Fourier transform fluorescence recovery after photobleaching (FT-FRAP) with patterned illumination is theorized and demonstrated for quantitatively evaluating normal and anomalous diffusion. Diffusion characterization is routinely performed to assess mobility in cell biology, pharmacology, and food science. Conventional FRAP is noninvasive, has low sample volume requirements, and can rapidly measure diffusion over distances of a few micrometers. However, conventional point-bleach measurements are complicated by signal-to-noise limitations, the need for precise knowledge of the photobleach beam profile, potential for bias due to sample heterogeneity, and poor compatibility with multiphoton excitation because of local heating. In FT-FRAP with patterned illumination, the time-dependent fluorescence recovery signal is concentrated to puncta in the spatial Fourier domain, with substantial improvements in signal-to-noise, mathematical simplicity, representative sampling, and multiphoton compatibility. A custom nonlinear optical beam-scanning microscope enabled patterned illumination for photobleaching through two-photon excitation. Measurements in the spatial Fourier domain removed dependence on the photobleach profile, suppressing bias from imprecise knowledge of the point spread function. For normal diffusion, the fluorescence recovery produced a simple single-exponential decay in the spatial Fourier domain, in excellent agreement with theoretical predictions. Simultaneous measurement of diffusion at multiple length scales was enabled through analysis of multiple spatial harmonics of the photobleaching pattern. Anomalous diffusion was characterized by FT-FRAP through a nonlinear fit to multiple spatial harmonics of the fluorescence recovery. Constraining the fit to describe diffusion over multiple length scales resulted in higher confidence in the recovered fitting parameters. Additionally, phase analysis in FT-FRAP was shown to inform on flow/sample translation.
Collapse
Affiliation(s)
- Andreas C Geiger
- Department of Chemistry, Purdue University, West Lafayette, Indiana
| | - Casey J Smith
- Department of Chemistry, Purdue University, West Lafayette, Indiana
| | - Nita Takanti
- Department of Chemistry, Purdue University, West Lafayette, Indiana
| | - Dustin M Harmon
- Department of Chemistry, Purdue University, West Lafayette, Indiana
| | - Mark S Carlsen
- Jonathan Amy Facility for Chemical Instrumentation, Purdue University, West Lafayette, Indiana
| | - Garth J Simpson
- Department of Chemistry, Purdue University, West Lafayette, Indiana.
| |
Collapse
|
10
|
Fluorescence recovery after photobleaching: direct measurement of diffusion anisotropy. Biomech Model Mechanobiol 2020; 19:2397-2412. [PMID: 32562093 DOI: 10.1007/s10237-020-01346-z] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/29/2019] [Accepted: 05/12/2020] [Indexed: 10/24/2022]
Abstract
Fluorescence recovery after photobleaching (FRAP) is a widely used technique for studying diffusion in biological tissues. Most of the existing approaches for the analysis of FRAP experiments assume isotropic diffusion, while only a few account for anisotropic diffusion. In fibrous tissues, such as articular cartilage, tendons and ligaments, diffusion, the main mechanism for molecular transport, is anisotropic and depends on the fibre alignment. In this work, we solve the general diffusion equation governing a FRAP test, assuming an anisotropic diffusivity tensor and using a general initial condition for the case of an elliptical (thereby including the case of a circular) bleaching profile. We introduce a closed-form solution in the spatial coordinates, which can be applied directly to FRAP tests to extract the diffusivity tensor. We validate the approach by measuring the diffusivity tensor of [Formula: see text] FITC-Dextran in porcine medial collateral ligaments. The measured diffusion anisotropy was [Formula: see text] (SE), which is in agreement with that reported in the literature. The limitations of the approach, such as the size of the bleached region and the intensity of the bleaching, are studied using COMSOL simulations.
Collapse
|
11
|
Travascio F, Devaux F, Volz M, Jackson AR. Molecular and macromolecular diffusion in human meniscus: relationships with tissue structure and composition. Osteoarthritis Cartilage 2020; 28:375-382. [PMID: 31917232 PMCID: PMC7248550 DOI: 10.1016/j.joca.2019.12.006] [Citation(s) in RCA: 15] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/30/2019] [Revised: 12/14/2019] [Accepted: 12/22/2019] [Indexed: 02/07/2023]
Abstract
OBJECTIVE To date, the pathophysiology of the meniscus has not been fully elucidated. Due to the tissue's limited vascularization, nutrients and other molecular signals spread through the extracellular matrix via diffusion or convection (interstitial fluid flow). Understanding transport mechanisms is crucial to elucidating meniscal pathophysiology, and to designing treatments for repair and restoration of the tissue. Similar to other fibrocartilaginous structures, meniscal morphology and composition may affect its diffusive properties. The objective of this study was to investigate the role of solute size, and tissue structure and composition on molecular diffusion in meniscus tissue. DESIGN Using a custom FRAP technique developed in our lab, we measured the direction-dependent diffusivity in human meniscus of six different molecular probes of size ranging from ∼300Da to 150,000Da. Diffusivity measurements were related to sample water content. SEM images were used to investigate collagen structure in relation to transport mechanisms. RESULTS Diffusivity was anisotropic, being significantly faster in the direction parallel to collagen fibers when compared the orthogonal direction. This was likely due to the unique structural organization of the tissue presenting pores aligned with the fibers, as observed in SEM images. Diffusion coefficients decreased as the molecular size increased, following the Ogston model. No significant correlations were found among diffusion coefficients and water content of the tissue. CONCLUSIONS This study provides new knowledge on the mechanisms of molecular transport in meniscal tissue. The reported results can be leveraged to further investigate tissue pathophysiology and to design treatments for tissue restoration or replacement.
Collapse
Affiliation(s)
- F Travascio
- Department of Industrial Engineering, University of Miami, Coral Gables, FL, USA; Max Biedermann Institute for Biomechanics at Mount Sinai Medical Center, Miami Beach, FL, USA.
| | - F Devaux
- Department of Biomedical Engineering, University of Miami, Coral Gables, FL, USA
| | - M Volz
- Department of Biomedical Engineering, University of Miami, Coral Gables, FL, USA
| | - A R Jackson
- Department of Biomedical Engineering, University of Miami, Coral Gables, FL, USA.
| |
Collapse
|
12
|
Graham BT, Wright AD, Burris DL, Axe MJ, Raisis LW, Price C. Quantification of solute diffusivity in osteoarthritic human femoral cartilage using correlation spectroscopy. J Orthop Res 2018; 36:3256-3267. [PMID: 30183098 DOI: 10.1002/jor.24138] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/22/2018] [Accepted: 08/25/2018] [Indexed: 02/04/2023]
Abstract
Osteoarthritis is a chronic joint disease characterized by articular cartilage degeneration, pain, and disability. As an avascular tissue, the movement of water and solutes through the tissue is critical to cartilage health and function, and early changes in solute diffusivity due to micro-scale changes in the properties of cartilage's extracellular matrix might precede clinical symptoms. A diagnostic technique for quantifying alteration to the diffusive environment of cartilage that precedes macroscopic changes may allow for the earlier identification of osteoarthritic disease, facilitating earlier intervention strategies. Toward this end, we used two confocal microscopy-based correlation spectroscopy techniques, fluorescence correlation spectroscopy and raster image correlation spectroscopy, to quantify the diffusion of two small solutes, fluorescein and 3k dextran, within human osteoarthritic articular cartilage. Our goal was to determine if these relatively simple optical correlation spectroscopy techniques could detect changes in solute diffusivity associated with increasing cartilage damage as assessed by International Cartilage Repair Society scoring guidelines, and if these measures are correlated with mechanical and compositional measures of cartilage health. Our data show a modest, yet significant increase in solute diffusivity and cartilage permeability with increasing osteoarthritis score (grades 0-2), with a strong correlation between diffusion coefficients, permeability, and cartilage composition. The described correlation spectroscopy techniques are quick, simple, and easily adapted to existing laboratory workflow and equipment. Furthermore, the minimal solute concentrations and laser powers required for analysis, combined with recent advances in arthroscopic microscopy, suggest correlation spectroscopy techniques as translational candidates for development into early OA diagnosis tools. © 2018 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 36:3256-3267, 2018.
Collapse
Affiliation(s)
- Brian T Graham
- Department of Mechanical Engineering, University of Delaware, Newark, Delaware
| | - Alison D Wright
- Department of Biomedical Engineering, University of Delaware, Newark, Delaware
| | - David L Burris
- Department of Mechanical Engineering, University of Delaware, Newark, Delaware.,Department of Biomedical Engineering, University of Delaware, Newark, Delaware
| | - Michael J Axe
- Department of Physical Therapy, University of Delaware, Newark, Delaware.,First State Orthopaedics, Christiana Care Health System, Newark, Delaware
| | - Leo W Raisis
- Department of Physical Therapy, University of Delaware, Newark, Delaware.,First State Orthopaedics, Christiana Care Health System, Newark, Delaware
| | - Christopher Price
- Department of Mechanical Engineering, University of Delaware, Newark, Delaware.,Department of Biomedical Engineering, University of Delaware, Newark, Delaware
| |
Collapse
|
13
|
Gallo LM, Fankhauser N, Gonzalez YM, Liu H, Liu Y, Nickel JC, Iwasaki LR. Jaw closing movement and sex differences in temporomandibular joint energy densities. J Oral Rehabil 2018; 45:97-103. [PMID: 29164651 PMCID: PMC5799013 DOI: 10.1111/joor.12588] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 11/15/2017] [Indexed: 01/22/2023]
Abstract
Energy densities (ED, mJ/mm3 ) quantify mechanical work imposed on articular cartilages during function. This cross-sectional study examined differences in temporomandibular joint (TMJ) ED during asymmetric versus symmetric jaw closing in healthy females versus males. ED component variables were tested for differences between and within sexes for two types of jaw closing. Seventeen female and 17 male subjects gave informed consent to participate. Diagnostic criteria for temporomandibular disorders and images (magnetic resonance (MR), computed tomography) were used to confirm healthy TMJ status. Numerical modelling predicted TMJ loads (Fnormal ) consequent to unilateral canine biting. Dynamic stereometry combined MR imaging and jaw-tracking data to measure ED component variables during 10 trials of each type of jaw closing in each subject's TMJs. These data were then used to calculate TMJ ED during jaw closing asymmetrically and symmetrically. Paired and Student's t tests assessed ED between jaw closing movements and sexes, respectively. Multivariate data analyses assessed ED component variable differences between jaw closing movements and sexes (α = 0.05). Contralateral TMJ ED were 3.6-fold and significantly larger (P < .0001) during asymmetric versus symmetric jaw closing, due to significantly larger (P ≤ .001) distances of TMJ stress-field translation in asymmetric versus symmetric movement. During asymmetric jaw closing, contralateral TMJ ED were twofold and significantly larger (P = .036) in females versus males, due to 1.5-fold and significantly smaller (P ≤ .010) TMJ disc cartilage volumes under stress fields in females versus males. These results suggest that in healthy individuals, asymmetric compared to symmetric jaw closure in females compared to males has higher TMJ mechanical fatigue liabilities.
Collapse
Affiliation(s)
- L M Gallo
- Department of Masticatory Disorders, School of Dental Medicine, University of Zurich, Zurich, Switzerland
| | - N Fankhauser
- Department of Masticatory Disorders, School of Dental Medicine, University of Zurich, Zurich, Switzerland
| | - Y M Gonzalez
- Department of Oral Diagnostic Sciences, School of Dental Medicine, University at Buffalo, Buffalo, NY, USA
| | - H Liu
- Departments of Orthodontics & Dentofacial Orthopedics and Oral & Craniofacial Sciences, School of Dentistry, University of Missouri-Kansas City, Kansas City, MO, USA
| | - Y Liu
- Department of Biostatistics & Epidemiology, East Tennessee State University, Johnson City, TN, USA
| | - J C Nickel
- Departments of Orthodontics & Dentofacial Orthopedics and Oral & Craniofacial Sciences, School of Dentistry, University of Missouri-Kansas City, Kansas City, MO, USA
| | - L R Iwasaki
- Departments of Orthodontics & Dentofacial Orthopedics and Oral & Craniofacial Sciences, School of Dentistry, University of Missouri-Kansas City, Kansas City, MO, USA
| |
Collapse
|
14
|
Iwasaki L, Gonzalez Y, Liu Y, Liu H, Markova M, Gallo L, Nickel J. Mechanobehavioral Scores in Women with and without TMJ Disc Displacement. J Dent Res 2017; 96:895-901. [PMID: 28414608 PMCID: PMC5502957 DOI: 10.1177/0022034517704375] [Citation(s) in RCA: 16] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022] Open
Abstract
Cartilage fatigue may be a factor in the precocious development of degenerative changes in the temporomandibular joint (TMJ). This cross-sectional study estimated potential for cartilage fatigue via TMJ energy densities (ED) and jaw muscle duty factors (DF), which were combined to calculate mechanobehavioral scores (MBS) in women with (+) and without (-) bilateral TMJ disc displacement (DD). All subjects gave informed consent to participate and were examined using Diagnostic Criteria (DC) for Temporomandibular Disorders (TMD) and magnetic resonance (MR) and computed tomography (CT) images. Forty-seven subjects were categorized into +DD ( n = 29) and -DD ( n = 18) groups. Dynamic stereometry (MR images combined with jaw-tracking data) characterized individual-specific data of TMJ stress-field mechanics to determine ED (ED = W/ Q mJ/mm3, where W = work done, Q = volume of cartilage) during 10 symmetrical jaw-closing cycles with a 20-N mandibular right canine load. Subjects were trained to record masseter and temporalis electromyography over 3 days and 3 nights. Root mean square electromyography/bite-force calibrations determined subject-specific masseter and temporalis muscle activities per 20-N bite-force (T20 N, µV), which defined thresholds. Muscle DF (DF = % duration of muscle activity/total recording time) were determined for a range of thresholds, and MBS (ED2 × DF) were calculated. Intergroup differences in ED, DF, and MBS were assessed via analyses of variance with Bonferroni and Tukey honest significant difference post hoc tests. Average ED for contralateral TMJs was significantly larger ( P = 0.012) by 1.4-fold in +DD compared to -DD subjects. Average DF were significantly larger (all P < 0.01) for +DD compared to -DD subjects by 1.7-, 2.5-, and 1.9-fold for day, night, and overall, respectively. Daytime MBS were significantly larger (all P < 0.04) by up to 8.5-fold in +DD compared to -DD subjects. Significantly larger ED, DF, and MBS were shown in women with compared to women without bilateral TMJ DD.
Collapse
Affiliation(s)
- L.R. Iwasaki
- School of Dentistry, Departments of Orthodontics & Dentofacial Orthopedics and Oral & Craniofacial Sciences, University of Missouri–Kansas City, Kansas City, MO, USA
| | - Y.M. Gonzalez
- School of Dental Medicine, Department of Oral Diagnostic Sciences, University at Buffalo, Buffalo, NY, USA
| | - Y. Liu
- Department of Biostatistics and Epidemiology, East Tennessee State University, Johnson City, TN, USA
| | - H. Liu
- School of Dentistry, Departments of Orthodontics & Dentofacial Orthopedics and Oral & Craniofacial Sciences, University of Missouri–Kansas City, Kansas City, MO, USA
| | - M. Markova
- Department of Masticatory Disorders, University of Zurich School of Dental Medicine, Zurich, Switzerland
| | - L.M. Gallo
- Department of Masticatory Disorders, University of Zurich School of Dental Medicine, Zurich, Switzerland
| | - J.C. Nickel
- School of Dentistry, Departments of Orthodontics & Dentofacial Orthopedics and Oral & Craniofacial Sciences, University of Missouri–Kansas City, Kansas City, MO, USA
| |
Collapse
|
15
|
Cisewski SE, Zhang L, Kuo J, Wright GJ, Wu Y, Kern MJ, Yao H. The effects of oxygen level and glucose concentration on the metabolism of porcine TMJ disc cells. Osteoarthritis Cartilage 2015; 23:1790-6. [PMID: 26033165 PMCID: PMC4577453 DOI: 10.1016/j.joca.2015.05.021] [Citation(s) in RCA: 16] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/17/2014] [Revised: 04/30/2015] [Accepted: 05/21/2015] [Indexed: 02/02/2023]
Abstract
OBJECTIVE To determine the combined effect of oxygen level and glucose concentration on cell viability, ATP production, and matrix synthesis of temporomandibular joint (TMJ) disc cells. DESIGN TMJ disc cells were isolated from pigs aged 6-8 months and cultured in a monolayer. Cell cultures were preconditioned for 48 h with 0, 1.5, 5, or 25 mM glucose DMEM under 1%, 5%, 10%, or 21% O2 level, respectively. The cell viability was measured using the WST-1 assay. ATP production was determined using the Luciferin-Luciferase assay. Collagen and proteoglycan synthesis were determined by measuring the incorporation of [2, 3-(3)H] proline and [(35)S] sulfate into the cells, respectively. RESULTS TMJ disc cell viability significantly decreased (P < 0.0001) without glucose. With glucose present, decreased oxygen levels significantly increased viability (P < 0.0001), while a decrease in glucose concentration significantly decreased viability (P < 0.0001). With glucose present, decreasing oxygen levels significantly reduced ATP production (P < 0.0001) and matrix synthesis (P < 0.0001). A decreased glucose concentration significantly decreased collagen synthesis (P < 0.0001). The interaction between glucose and oxygen was significant in regards to cell viability (P < 0.0001), ATP production (P = 0.00015), and collagen (P = 0.0002) and proteoglycan synthesis (P < 0.0001). CONCLUSIONS Although both glucose and oxygen are important, glucose is the limiting nutrient for TMJ disc cell survival. At low oxygen levels, the production of ATP, collagen, and proteoglycan are severely inhibited. These results suggest that steeper nutrient gradients may exist in the TMJ disc and it may be vulnerable to pathological events that impede nutrient supply.
Collapse
Affiliation(s)
| | - Lixia Zhang
- Department of Oral Health Sciences, Medical University of South Carolina (MUSC), Charleston, SC
| | - Jonathan Kuo
- Department of Bioengineering, Clemson University, Clemson, SC
| | | | - Yongren Wu
- Department of Bioengineering, Clemson University, Clemson, SC
| | - Michael J. Kern
- Department of Oral Health Sciences, Medical University of South Carolina (MUSC), Charleston, SC
| | - Hai Yao
- Department of Bioengineering, Clemson University, Clemson, SC
,Department of Oral Health Sciences, Medical University of South Carolina (MUSC), Charleston, SC
| |
Collapse
|
16
|
Gallo LM, Iwasaki LR, Gonzalez YM, Liu H, Marx DB, Nickel JC. Diagnostic group differences in temporomandibular joint energy densities. Orthod Craniofac Res 2015; 18 Suppl 1:164-9. [PMID: 25865545 PMCID: PMC4396680 DOI: 10.1111/ocr.12074] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 11/24/2014] [Indexed: 11/29/2022]
Abstract
OBJECTIVES Cartilage fatigue, due to mechanical work, may account for precocious development of degenerative joint disease in the temporomandibular joint (TMJ). This study compared energy densities (mJ/mm³) in TMJs of three diagnostic groups. SETTING AND SAMPLE POPULATION Sixty-eight subjects (44 women, 24 men) gave informed consent. Diagnostic criteria for temporomandibular disorders (DC/TMD) and imaging were used to group subjects according to presence of jaw muscle or joint pain (+P) and bilateral disk displacement (+DD). MATERIAL AND METHODS Subjects (+P+DD, n=16; -P+DD, n=16; and -P-DD, n=36) provided cone-beam computed tomography and magnetic resonance images, and jaw-tracking data. Numerical modeling was used to determine TMJ loads (Fnormal). Dynamic stereometry was used to characterize individual-specific data of stress-field dynamics during 10 symmetrical jaw-closing cycles. These data were used to estimate tractional forces (Ftraction). Energy densities were then calculated as W/Q (W=work done or mechanical energy input=tractional force×distance of stress-field translation, Q=volume of cartilage). anova and Tukey-Kramer post hoc analyses tested for intergroup differences. RESULTS Mean±standard error energy density for the +P+DD group was 12.7±1.5 mJ/mm³ and significantly greater (all adjusted p<0.04) when compared to -P+DD (7.4±1.4 mJ/mm³) and -P-DD (5.8±0.9 mJ/mm³) groups. Energy densities in -P+DD and -P-DD groups were not significantly different. CONCLUSION Diagnostic group differences in energy densities suggest that mechanical work may be a unique mechanism, which contributes to cartilage fatigue in subjects with pain and disk displacement.
Collapse
Affiliation(s)
- L M Gallo
- Center of Dental Medicine, Clinic of Masticatory Disorders, Removable Prosthodontics, Geriatric and Special Care Dentistry, University of Zurich, Zurich, Switzerland
| | | | | | | | | | | |
Collapse
|
17
|
Shi C, Cisewski SE, Bell PD, Yao H. Measurement of three-dimensional anisotropic diffusion by multiphoton fluorescence recovery after photobleaching. Ann Biomed Eng 2013; 42:555-65. [PMID: 24248560 DOI: 10.1007/s10439-013-0939-7] [Citation(s) in RCA: 11] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/11/2013] [Accepted: 11/09/2013] [Indexed: 11/25/2022]
Abstract
The multiphoton fluorescence recovery after photobleaching (MP-FRAP) technique has been developed to measure the three-dimensional (3D) solute diffusion within biological systems. However, current 3D MP-FRAP models are based on isotropic diffusion and spatial domain analysis. The 3D anisotropic diffusion and frequency domain analysis for MP-FRAP measurements are rarely studied. In this study, a new technique is demonstrated for the quantitative and non-destructive determination of 3D anisotropic solute diffusion tensors within biological fibrosis tissues by multiphoton photobleaching and spatial Fourier analysis (SFA). Compared to the spatial domain analysis based MP-FRAP techniques, this SFA-based method has the capability for determining the 3D anisotropic diffusion tensors as well as the flexibility for satisfying initial and boundary conditions. First, a close-form solution of the 3D anisotropic diffusion equation is derived by solely using SFA. Next, this new method is validated by computer-simulated MP-FRAP experiments with pre-defined 3D anisotropic diffusion tensors as well as experimental diffusion measurements of FITC-Dextran (FD) molecules in aqueous glycerol solutions. Finally, this MP-FRAP technique is applied to the measurement of 3D anisotropic diffusion tensors of FD molecules within porcine tendon tissues. This study provides a new tool for complete determination of 3D anisotropic solute diffusion tensor in biological tissues.
Collapse
Affiliation(s)
- Changcheng Shi
- CU-MUSC Bioengineering Program, Department of Bioengineering, Clemson University, 173 Ashley Avenue, P.O. Box 250508, Charleston, SC, 29425, USA
| | | | | | | |
Collapse
|
18
|
Wright GJ, Kuo J, Shi C, Bacro TRH, Slate EH, Yao H. Effect of mechanical strain on solute diffusion in human TMJ discs: an electrical conductivity study. Ann Biomed Eng 2013; 41:2349-57. [PMID: 23771300 DOI: 10.1007/s10439-013-0840-4] [Citation(s) in RCA: 16] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/13/2013] [Accepted: 06/04/2013] [Indexed: 11/26/2022]
Abstract
This study investigated the effect of mechanical strain on solute diffusion in human TMJ discs (mean cadaver age 77.8) using the electrical conductivity method. The electrical conductivity, as well as small ion diffusivity, of male and female TMJ discs was determined under three compressive strains. In the male group, the average disc electrical conductivity (mean ± SD) at 0% strain was 5.14 ± 0.97 mS/cm, decreased to 4.50 ± 0.91 mS/cm (-12.3%) at 10% strain, and 3.93 ± 0.81 mS/cm (-23.5%) at 20% compressive strain. Correspondingly, the average disc relative ion diffusivity at 0% strain was 0.44 ± 0.08, decreased to 0.40 ± 0.08 (-8.9%) at 10% strain, and 0.36 ± 0.08 (-16.7%) at 20% compressive strain. In the female group, the average disc electrical conductivity at 0% strain was 5.84 ± 0.59 mS/cm, decreased to 5.01 ± 0.50 mS/cm (-14.2%) at 10% strain, and 4.33 ± 0.46 mS/cm (-25.8%) at 20% compressive strain. Correspondingly, the average disc relative ion diffusivity at 0% strain was 0.49 ± 0.05, decreased to 0.43 ± 0.04 (-11.3%) at 10% strain, and 0.39 ± 0.04 (-19.9%) at 20% compressive strain. The results indicated that mechanical strain significantly impeded solute diffusion through the disc. This mechanical strain effect was larger in the female than in the male human TMJ disc. This study may provide new insights into TMJ pathophysiology.
Collapse
Affiliation(s)
- Gregory J Wright
- Clemson-MUSC Bioengineering Program, Department of Bioengineering, Clemson University, 173 Ashley Avenue, P.O. Box 250508, Charleston, SC, 29425, USA
| | | | | | | | | | | |
Collapse
|
19
|
Shi C, Wright GJ, Ex-Lubeskie CL, Bradshaw AD, Yao H. Relationship between anisotropic diffusion properties and tissue morphology in porcine TMJ disc. Osteoarthritis Cartilage 2013; 21:625-33. [PMID: 23353670 PMCID: PMC3602227 DOI: 10.1016/j.joca.2013.01.010] [Citation(s) in RCA: 28] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/06/2012] [Revised: 01/09/2013] [Accepted: 01/15/2013] [Indexed: 02/02/2023]
Abstract
OBJECTIVE To investigate the relationship between anisotropic solute diffusion properties and tissue morphology in porcine temporomandibular joint (TMJ) discs. DESIGN TMJ discs from eleven pigs aged 6-8 months were divided into five regions: anterior, intermediate, posterior, lateral, and medial. The transport properties and tissue morphology were investigated in three orthogonal orientations: anteroposterior (AP), mediolateral (ML), and superoinferior (SI). The anisotropic diffusivity of fluorescein (332 Da) in the right discs was determined by the fluorescence recovery after photobleaching (FRAP) protocols. The tissue morphology in the left discs was quantified by scanning electron microscopy. RESULTS The diffusivities of fluorescein in the TMJ disc were significantly anisotropic, except for the anterior region. In the medial, intermediate, and lateral regions, the diffusion along the fiber orientation (i.e., AP direction) was significantly faster than the diffusion in ML and SI directions. In the posterior region, the diffusion along the fiber orientation (i.e., ML direction) was significantly faster than the diffusion in AP and SI directions. The diffusion in the anterior region was mostly isotropic with the lowest degree of diffusion anisotropy, as well as collagen fiber alignment, likely due to the multi-directional fiber arrangement. The anterior region had the highest mean diffusivity [65.6 (49.3-81.8) μm(2)/s] in the disc, likely due to its high water content. The overall average diffusivity of fluorescein across the TMJ disc was 57.0 (43.0-71.0) μm(2)/s. CONCLUSIONS The solute diffusion in porcine TMJ discs was strongly anisotropic and inhomogeneous, which associated with tissue structure (i.e., collagen fiber alignment) and composition (e.g., water content).
Collapse
Affiliation(s)
- Changcheng Shi
- Department of Bioengineering, Clemson University, Clemson, SC
| | | | | | - Amy D. Bradshaw
- Department of Craniofacial Biology, Medical University of South Carolina (MUSC), Charleston, SC
| | - Hai Yao
- Department of Bioengineering, Clemson University, Clemson, SC
- Department of Craniofacial Biology, Medical University of South Carolina (MUSC), Charleston, SC
| |
Collapse
|
20
|
Kuo J, Wright GJ, Bach DE, Slate EH, Yao H. Effect of mechanical loading on electrical conductivity in porcine TMJ discs. J Dent Res 2011; 90:1216-20. [PMID: 21743033 DOI: 10.1177/0022034511415275] [Citation(s) in RCA: 18] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022] Open
Abstract
The objective of this study was to examine the impact of mechanical loading on solute transport in porcine temporomandibular joint (TMJ) discs using the electrical conductivity method. The electrical conductivity, as well as ion diffusivity, of TMJ discs was determined under confined compression with 3 strains in 5 disc regions. The average electrical conductivity over the 5 regions (mean ± SD) at 0% strain was 3.10 ± 0.68 mS/cm, decreased to 2.76 ± 0.58 mS/cm (-11.0%) at 10% strain, and 2.38 ± 0.55 mS/cm (-22.2%) at 20% compressive strain. Correspondingly, the average relative ion diffusivity (mean ± SD) at 0% strain was 0.273 ± 0.055, decreased to 0.253 ± 0.048 (-7.3%) at 10% strain, and 0.231 ± 0.048 (-15.4%) at 20% compressive strain. These results indicated that compressive strain impeded solute transport in the TMJ disc. Furthermore, our results showed that the transport properties of TMJ discs were region-dependent. The electrical conductivity and ion diffusivity in the anterior region were significantly higher than in the posterior region. This regional difference is likely due to the significant differences of tissue hydration between these 2 regions. This study provides important insight into the electrical and solute transport behaviors in TMJ discs under mechanical loading and aids in the understanding of TMJ pathophysiology related to tissue nutrition.
Collapse
Affiliation(s)
- J Kuo
- Department of Bioengineering, Clemson University, Clemson, SC, USA
| | | | | | | | | |
Collapse
|
21
|
Morbiducci U, Ponzini R, Rizzo G, Cadioli M, Esposito A, Montevecchi FM, Redaelli A. Mechanistic insight into the physiological relevance of helical blood flow in the human aorta: an in vivo study. Biomech Model Mechanobiol 2010; 10:339-55. [PMID: 20652615 DOI: 10.1007/s10237-010-0238-2] [Citation(s) in RCA: 153] [Impact Index Per Article: 10.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/22/2009] [Accepted: 06/30/2010] [Indexed: 10/19/2022]
Abstract
The hemodynamics within the aorta of five healthy humans were investigated to gain insight into the complex helical flow patterns that arise from the existence of asymmetries in the aortic region. The adopted approach is aimed at (1) overcoming the relative paucity of quantitative data regarding helical blood flow dynamics in the human aorta and (2) identifying common characteristics in physiological aortic flow topology, in terms of its helical content. Four-dimensional phase-contrast magnetic resonance imaging (4D PC MRI) was combined with algorithms for the calculation of advanced fluid dynamics in this study. These algorithms allowed us to obtain a 4D representation of intra-aortic flow fields and to quantify the aortic helical flow. For our purposes, helicity was used as a measure of the alignment of the velocity and the vorticity. There were two key findings of our study: (1) intra-individual analysis revealed a statistically significant difference in the helical content at different phases of systole and (2) group analysis suggested that aortic helical blood flow dynamics is an emerging behavior that is common to normal individuals. Our results also suggest that helical flow might be caused by natural optimization of fluid transport processes in the cardiovascular system, aimed at obtaining efficient perfusion. The approach here applied to assess in vivo helical blood flow could be the starting point to elucidate the role played by helicity in the generation and decay of rotating flows in the thoracic aorta.
Collapse
Affiliation(s)
- Umberto Morbiducci
- Department of Mechanics, Politecnico di Torino, Corso Duca degli Abruzzi, 24, 10129, Turin, Italy.
| | | | | | | | | | | | | |
Collapse
|