Lin J, Chen S, Zhang C, Liao J, Chen Y, Deng S, Mao Z, Zhang T, Tian N, Song Y, Zeng T. Recent advances in microfluidic technology of arterial thrombosis investigations. Platelets 2024; 35:2316743. [PMID: 38390892 DOI: 10.1080/09537104.2024.2316743] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/27/2023] [Accepted: 02/05/2024] [Indexed: 02/24/2024]
Abstract
Microfluidic technology has emerged as a powerful tool in studying arterial thrombosis, allowing researchers to construct artificial blood vessels and replicate the hemodynamics of blood flow. This technology has led to significant advancements in understanding thrombosis and platelet adhesion and aggregation. Microfluidic models have various types and functions, and by studying the fabrication methods and working principles of microfluidic chips, applicable methods can be selected according to specific needs. The rapid development of microfluidic integrated system and modular microfluidic system makes arterial thrombosis research more diversified and automated, but its standardization still needs to be solved urgently. One key advantage of microfluidic technology is the ability to precisely control fluid flow in microchannels and to analyze platelet behavior under different shear forces and flow rates. This allows researchers to study the physiological and pathological processes of blood flow, shedding light on the underlying mechanisms of arterial thrombosis. In conclusion, microfluidic technology has revolutionized the study of arterial thrombosis by enabling the construction of artificial blood vessels and accurately reproducing hemodynamics. In the future, microfluidics will place greater emphasis on versatility and automation, holding great promise for advancing antithrombotic therapeutic and prophylactic measures.
Collapse
Affiliation(s)
- Jingying Lin
- Department of Laboratory Medicine, West China Hospital, Sichuan University, Chengdu, China
- Department of Laboratory Medicine, Chengdu Shangjin Nanfu Hospital/Shangjin Branch of West China Hospital, Sichuan University, Chengdu, China
| | - Si Chen
- Department of Laboratory Medicine, West China Hospital, Sichuan University, Chengdu, China
| | - Chunying Zhang
- Department of Laboratory Medicine, West China Hospital, Sichuan University, Chengdu, China
| | - Juan Liao
- Department of Laboratory Medicine, West China Hospital, Sichuan University, Chengdu, China
| | - Yuemei Chen
- Department of Laboratory Medicine, West China Hospital, Sichuan University, Chengdu, China
| | - Shanying Deng
- Department of Laboratory Medicine, West China Hospital, Sichuan University, Chengdu, China
| | - Zhigang Mao
- Department of Laboratory Medicine, West China Hospital, Sichuan University, Chengdu, China
| | - Tonghao Zhang
- Department of Statistics, University of Virginia, Charlottesville, USA
| | - Na Tian
- Anesthesiology Department, Qingdao Eighth People's Hospital, Qingdao, China
| | - Yali Song
- Department of Laboratory Medicine, West China Hospital, Sichuan University, Chengdu, China
| | - Tingting Zeng
- Department of Laboratory Medicine, West China Hospital, Sichuan University, Chengdu, China
| |
Collapse
|
2
|
Maksić M, Corović I, Stanisavljević I, Radojević D, Veljković T, Todorović Ž, Jovanović M, Zdravković N, Stojanović B, Marković BS, Jovanović I. Heyde Syndrome Unveiled: A Case Report with Current Literature Review and Molecular Insights. Int J Mol Sci 2024; 25:11041. [PMID: 39456826 PMCID: PMC11507012 DOI: 10.3390/ijms252011041] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/08/2024] [Revised: 09/23/2024] [Accepted: 09/26/2024] [Indexed: 10/28/2024] Open
Abstract
Heyde syndrome, marked by aortic stenosis, gastrointestinal bleeding from angiodysplasia, and acquired von Willebrand syndrome, is often underreported. Shear stress from a narrowed aortic valve degrades von Willebrand factor multimers, leading to angiodysplasia formation and von Willebrand factor deficiency. This case report aims to raise clinician awareness of Heyde syndrome, its complexity, and the need for a multidisciplinary approach. We present a 75-year-old man with aortic stenosis, gastrointestinal bleeding from angiodysplasia, and acquired von Willebrand syndrome type 2A. The patient was successfully treated with argon plasma coagulation and blood transfusions. He declined further treatment for aortic stenosis but was in good overall health with improved laboratory results during follow-up. Additionally, we provide a comprehensive review of the molecular mechanisms involved in the development of this syndrome, discuss current diagnostic and treatment approaches, and offer future perspectives for further research on this topic.
Collapse
Affiliation(s)
- Mladen Maksić
- Department of Internal Medicine, Faculty of Medical Sciences, University of Kragujevac, Svetozara Markovica 69, 34000 Kragujevac, Serbia; (M.M.); (D.R.); (Ž.T.); (M.J.); (N.Z.)
| | - Irfan Corović
- Center for Molecular Medicine and Stem Cell Research, Faculty of Medical Sciences, University of Kragujevac, Svetozara Markovica 69, 34000 Kragujevac, Serbia; (I.C.); (I.S.); (I.J.)
| | - Isidora Stanisavljević
- Center for Molecular Medicine and Stem Cell Research, Faculty of Medical Sciences, University of Kragujevac, Svetozara Markovica 69, 34000 Kragujevac, Serbia; (I.C.); (I.S.); (I.J.)
| | - Dušan Radojević
- Department of Internal Medicine, Faculty of Medical Sciences, University of Kragujevac, Svetozara Markovica 69, 34000 Kragujevac, Serbia; (M.M.); (D.R.); (Ž.T.); (M.J.); (N.Z.)
| | - Tijana Veljković
- Department of Pediatrics, Faculty of Medical Sciences, University of Kragujevac, Svetozara Markovica 69, 34000 Kragujevac, Serbia;
| | - Željko Todorović
- Department of Internal Medicine, Faculty of Medical Sciences, University of Kragujevac, Svetozara Markovica 69, 34000 Kragujevac, Serbia; (M.M.); (D.R.); (Ž.T.); (M.J.); (N.Z.)
| | - Marina Jovanović
- Department of Internal Medicine, Faculty of Medical Sciences, University of Kragujevac, Svetozara Markovica 69, 34000 Kragujevac, Serbia; (M.M.); (D.R.); (Ž.T.); (M.J.); (N.Z.)
- Center for Molecular Medicine and Stem Cell Research, Faculty of Medical Sciences, University of Kragujevac, Svetozara Markovica 69, 34000 Kragujevac, Serbia; (I.C.); (I.S.); (I.J.)
| | - Nataša Zdravković
- Department of Internal Medicine, Faculty of Medical Sciences, University of Kragujevac, Svetozara Markovica 69, 34000 Kragujevac, Serbia; (M.M.); (D.R.); (Ž.T.); (M.J.); (N.Z.)
| | - Bojan Stojanović
- Department of Surgery, Faculty of Medical Sciences, University of Kragujevac, Svetozara Markovica 69, 34000 Kragujevac, Serbia;
| | - Bojana Simović Marković
- Center for Molecular Medicine and Stem Cell Research, Faculty of Medical Sciences, University of Kragujevac, Svetozara Markovica 69, 34000 Kragujevac, Serbia; (I.C.); (I.S.); (I.J.)
| | - Ivan Jovanović
- Center for Molecular Medicine and Stem Cell Research, Faculty of Medical Sciences, University of Kragujevac, Svetozara Markovica 69, 34000 Kragujevac, Serbia; (I.C.); (I.S.); (I.J.)
| |
Collapse
|
3
|
He W, Karmakar A, Kang J, Rowlands G, Schirmacher S, Méndez-Rojano R, Antaki J. In Vitro and In Silico Characterization of the Aggregation of Thrombi on Textured Ventricular Cannula. Ann Biomed Eng 2024; 52:2076-2087. [PMID: 38679660 DOI: 10.1007/s10439-024-03504-1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/07/2023] [Accepted: 03/25/2024] [Indexed: 05/01/2024]
Abstract
The unacceptably high stroke rate associated with HeartMate 3 ventricular assist device (VAD) without signs of adherent pump thrombosis is hypothesized to be the result of the emboli produced by the inflow cannula, that are ingested and ejected from the pump. This in vitro and numerical study aimed to emulate the surface features and supraphysiological shear of a ventricular cannula to provide insight into their effect on thrombogenesis. Human whole blood was perfused at calibrated flow rates in a microfluidic channel to achieve shear rates 1000-7500 s-1, comparable to that experienced on the cannula. The channel contained periodic teeth representative of the rough sintered surface of the HeartMate 3 cannula. The deposition of fluorescently labeled platelets was visualized in real time and analyzed with a custom entity tracking algorithm. Numerical simulations of a multi-constituent thrombosis model were performed to simulate laminar blood flow in the channel. The sustained growth of adherent platelets was observed in all shear conditions ( p < 0.05). However, the greatest deposition was observed at the lower shear rates. The location of deposition with respect to the microfluidic teeth was also found to vary with shear rate. This was confirmed by CFD simulation. The entity tracking algorithm revealed the spatial variation of instances of embolic events. This result suggests that the sintered surface of the ventricular cannula may engender unstable thrombi with a greater likelihood of embolization at supraphysiological shear rates.
Collapse
Affiliation(s)
- Wenxuan He
- Sibley School of Mechanical and Aerospace Engineering, Cornell University, Ithaca, NY, 14853, USA
| | - Abhishek Karmakar
- Meinig School of Biomedical Engineering, Cornell University, Ithaca, NY, 14853, USA
| | - Junhyuk Kang
- Sibley School of Mechanical and Aerospace Engineering, Cornell University, Ithaca, NY, 14853, USA
| | - Grant Rowlands
- Meinig School of Biomedical Engineering, Cornell University, Ithaca, NY, 14853, USA
| | - Samuel Schirmacher
- Meinig School of Biomedical Engineering, Cornell University, Ithaca, NY, 14853, USA
| | | | - James Antaki
- Meinig School of Biomedical Engineering, Cornell University, Ithaca, NY, 14853, USA.
| |
Collapse
|
4
|
Yeo EF, Oliver JM, Korin N, Waters SL. A continuum model for the elongation and orientation of Von Willebrand factor with applications in arterial flow. Biomech Model Mechanobiol 2024; 23:1299-1317. [PMID: 38592600 PMCID: PMC11341749 DOI: 10.1007/s10237-024-01840-8] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/23/2023] [Accepted: 03/10/2024] [Indexed: 04/10/2024]
Abstract
The blood protein Von Willebrand factor (VWF) is critical in facilitating arterial thrombosis. At pathologically high shear rates, the protein unfolds and binds to the arterial wall, enabling the rapid deposition of platelets from the blood. We present a novel continuum model for VWF dynamics in flow based on a modified viscoelastic fluid model that incorporates a single constitutive relation to describe the propensity of VWF to unfold as a function of the scalar shear rate. Using experimental data of VWF unfolding in pure shear flow, we fix the parameters for VWF's unfolding propensity and the maximum VWF length, so that the protein is half unfolded at a shear rate of approximately 5000 s - 1 . We then use the theoretical model to predict VWF's behaviour in two complex flows where experimental data are challenging to obtain: pure elongational flow and stenotic arterial flow. In pure elongational flow, our model predicts that VWF is 50% unfolded at approximately 2000 s - 1 , matching the established hypothesis that VWF unfolds at lower shear rates in elongational flow than in shear flow. We demonstrate the sensitivity of this elongational flow prediction to the value of maximum VWF length used in the model, which varies significantly across experimental studies, predicting that VWF can unfold between 2000 and 3200 s - 1 depending on the selected value. Finally, we examine VWF dynamics in a range of idealised arterial stenoses, predicting the relative extension of VWF in elongational flow structures in the centre of the artery compared to high shear regions near the arterial walls.
Collapse
Affiliation(s)
- E F Yeo
- Department of Mathematics, University College London, London, UK.
| | - J M Oliver
- Mathematical Institute, University of Oxford, Oxford, UK
| | - N Korin
- Biomedical Engineering, Technion, Haifa, Israel
| | - S L Waters
- Mathematical Institute, University of Oxford, Oxford, UK
| |
Collapse
|
5
|
Wagner MS, Kranz M, Krenkel L, Pointner D, Foltan M, Lubnow M, Lehle K. Computer based visualization of clot structures in extracorporeal membrane oxygenation and histological clot investigations for understanding thrombosis in membrane lungs. Front Med (Lausanne) 2024; 11:1416319. [PMID: 38962744 PMCID: PMC11219572 DOI: 10.3389/fmed.2024.1416319] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/12/2024] [Accepted: 06/06/2024] [Indexed: 07/05/2024] Open
Abstract
Extracorporeal membrane oxygenation (ECMO) was established as a treatment for severe cardiac or respiratory disease. Intra-device clot formation is a common risk. This is based on complex coagulation phenomena which are not yet sufficiently understood. The objective was the development and validation of a methodology to capture the key properties of clots deposed in membrane lungs (MLs), such as clot size, distribution, burden, and composition. One end-of-therapy PLS ML was examined. Clot detection was performed using multidetector computed tomography (MDCT), microcomputed tomography (μCT), and photography of fiber mats (fiber mat imaging, FMI). Histological staining was conducted for von Willebrand factor (vWF), platelets (CD42b, CD62P), fibrin, and nucleated cells (4', 6-diamidino-2-phenylindole, DAPI). The three imaging methods showed similar clot distribution inside the ML. Independent of the imaging method, clot loading was detected predominantly in the inlet chamber of the ML. The μCT had the highest accuracy. However, it was more expensive and time consuming than MDCT or FMI. The MDCT detected the clots with low scanning time. Due to its lower resolution, it only showed clotted areas but not the exact shape of clot structures. FMI represented the simplest variant, requiring little effort and resources. FMI allowed clot localization and calculation of clot volume. Histological evaluation indicated omnipresent immunological deposits throughout the ML. Visually clot-free areas were covered with leukocytes and platelets forming platelet-leukocyte aggregates (PLAs). Cells were embedded in vWF cobwebs, while vWF fibers were negligible. In conclusion, the presented methodology allowed adequate clot identification and histological classification of possible thrombosis markers such as PLAs.
Collapse
Affiliation(s)
- Maria S. Wagner
- Department of Cardiothoracic Surgery, University Hospital Regensburg, Regensburg, Germany
| | - Michael Kranz
- Department of Biofluid Mechanics, Faculty of Mechanical Engineering, Technical University of Applied Sciences (OTH) Regensburg, Regensburg, Germany
- Regensburg Center of Biomedical Engineering, Facility of University Regensburg and Technical University of Applied Sciences (OTH) Regensburg, Regensburg, Germany
| | - Lars Krenkel
- Department of Biofluid Mechanics, Faculty of Mechanical Engineering, Technical University of Applied Sciences (OTH) Regensburg, Regensburg, Germany
- Regensburg Center of Biomedical Engineering, Facility of University Regensburg and Technical University of Applied Sciences (OTH) Regensburg, Regensburg, Germany
| | - Daniel Pointner
- Department of Biofluid Mechanics, Faculty of Mechanical Engineering, Technical University of Applied Sciences (OTH) Regensburg, Regensburg, Germany
- Regensburg Center of Biomedical Engineering, Facility of University Regensburg and Technical University of Applied Sciences (OTH) Regensburg, Regensburg, Germany
| | - Maik Foltan
- Department of Cardiothoracic Surgery, University Hospital Regensburg, Regensburg, Germany
| | - Matthias Lubnow
- Department of Internal Medicine II, University Hospital Regensburg, Regensburg, Germany
| | - Karla Lehle
- Department of Cardiothoracic Surgery, University Hospital Regensburg, Regensburg, Germany
| |
Collapse
|
6
|
Grande Gutiérrez N, Mukherjee D, Bark D. Decoding thrombosis through code: a review of computational models. J Thromb Haemost 2024; 22:35-47. [PMID: 37657562 PMCID: PMC11064820 DOI: 10.1016/j.jtha.2023.08.021] [Citation(s) in RCA: 4] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/07/2022] [Revised: 08/15/2023] [Accepted: 08/22/2023] [Indexed: 09/03/2023]
Abstract
From the molecular level up to a blood vessel, thrombosis and hemostasis involves many interconnected biochemical and biophysical processes over a wide range of length and time scales. Computational modeling has gained eminence in offering insights into these processes beyond what can be obtained from in vitro or in vivo experiments, or clinical measurements. The multiscale and multiphysics nature of thrombosis has inspired a wide range of modeling approaches that aim to address how a thrombus forms and dismantles. Here, we review recent advances in computational modeling with a focus on platelet-based thrombosis. We attempt to summarize the diverse range of modeling efforts straddling the wide-spectrum of physical phenomena, length scales, and time scales; highlighting key advancements and insights from existing studies. Potential information gleaned from models is discussed, ranging from identification of thrombus-prone regions in patient-specific vasculature to modeling thrombus deformation and embolization in response to fluid forces. Furthermore, we highlight several limitations of current models, future directions in the field, and opportunities for clinical translation, to illustrate the state-of-the-art. There are a plethora of opportunity areas for which models can be expanded, ranging from topics of thromboinflammation to platelet production and clearance. Through successes demonstrated in existing studies described here, as well as continued advancements in computational methodologies and computer processing speeds and memory, in silico investigations in thrombosis are poised to bring about significant knowledge growth in the years to come.
Collapse
Affiliation(s)
- Noelia Grande Gutiérrez
- Carnegie Mellon University, Department of Mechanical Engineering Pittsburgh, PA, USA. https://twitter.com/ngrandeg
| | - Debanjan Mukherjee
- University of Colorado Boulder, Paul M. Rady Department of Mechanical Engineering Boulder, CO, USA. https://twitter.com/debanjanmukh
| | - David Bark
- Washington University in St Louis, Department of Pediatrics, Division of Hematology and Oncology St Louis, MO, USA; Washington University in St Louis, Department of Biomedical Engineering St Louis, MO, USA.
| |
Collapse
|
7
|
Li Y, Wang H, Xi Y, Sun A, Wang L, Deng X, Chen Z, Fan Y. A mathematical model for assessing shear induced bleeding risk. COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE 2023; 231:107390. [PMID: 36745955 DOI: 10.1016/j.cmpb.2023.107390] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/19/2022] [Revised: 01/16/2023] [Accepted: 01/30/2023] [Indexed: 06/18/2023]
Abstract
PURPOSE The objective of this study is to develop a bleeding risk model for assessing device-induced bleeding risk in patients supported with blood contact medical devices (BCMDs). METHODS The mathematical model for evaluating bleeding risk considers the effects of shear stress on von Willebrand factor (vWF) unfolding, high molecular weight multimers-vWF (HMWM-vWF) degradation, platelet activation and receptor shedding and platelet-vWF binding ability. Functions of the effect of shear stress on the above factors are fitted/employed and solved by the Eulerian transport equation. An axial flow-through Couette device and two clinical VADs which are HeartWare Ventricular Assist Device (HVAD) and HeartMate II (HM II) blood pump were employed to perform the simulation to evaluate platelet receptor shedding (GPIbα and GPIIb/IIIa), loss of HWMW-vWF, platelet-vWF binding ability and bleeding risk for validating the accuracy of our model. RESULTS The platelet-vWF binding ability after being subjected to high shear region in the axial flow-through Couette device predicted by our bleeding model was highly consistent with reported experimental data. As indicated by our CFD simulation results in the axial flow-through Couette device, it can find that an increase in shear stress led to a decrease in the adhesion ability of platelets on vWF, while the binding ability of vWF with platelets first increase and then decrease as shear stress elevates gradually beyond a threshold. The factor of exposure time can enhance the effect of shear stress. Additionally, the shear-induced bleeding risk predicted by our model increases with increasing shear stress and exposure time in an axial flow-through Couette device. As indicated by our numerical model, the bleeding risk in HVAD was higher than HMII, which is highly consistent with the meta-analysis based on clinical statistics. Our simulation investigations in these two clinical VADs also found that HVAD caused a higher rate of platelet receptor shedding and lower damage to HWMW-vWF than HeartMate II. The high shear stress generated in the narrow and turbulent regions of both VADs was the underlying cause of device-induced bleeding. CONCLUSION In this study, the shear-induced bleeding risk predicted by our bleeding model in axial flow-through Couette device and two clinical VADs is consistent or highly correlated with experimental and clinical findings, which proves the accuracy of our bleeding model. Our bleeding model can be used to aid the development of new BCMDs with improved functional characteristics and biocompatibility, and help to reduce risk of device-induced adverse events in patients.
Collapse
Affiliation(s)
- Yuan Li
- Key Laboratory of Biomechanics and Mechanobiology (Beihang University), Ministry of Education, Beijing Advanced Innovation Center for Biomedical Engineering, School of Biological Science and Medical Engineering, Beihang University, Beijing 100083, China
| | - Hongyu Wang
- Key Laboratory of Biomechanics and Mechanobiology (Beihang University), Ministry of Education, Beijing Advanced Innovation Center for Biomedical Engineering, School of Biological Science and Medical Engineering, Beihang University, Beijing 100083, China
| | - Yifeng Xi
- Key Laboratory of Biomechanics and Mechanobiology (Beihang University), Ministry of Education, Beijing Advanced Innovation Center for Biomedical Engineering, School of Biological Science and Medical Engineering, Beihang University, Beijing 100083, China
| | - Anqiang Sun
- Key Laboratory of Biomechanics and Mechanobiology (Beihang University), Ministry of Education, Beijing Advanced Innovation Center for Biomedical Engineering, School of Biological Science and Medical Engineering, Beihang University, Beijing 100083, China
| | - Lizhen Wang
- Key Laboratory of Biomechanics and Mechanobiology (Beihang University), Ministry of Education, Beijing Advanced Innovation Center for Biomedical Engineering, School of Biological Science and Medical Engineering, Beihang University, Beijing 100083, China
| | - Xiaoyan Deng
- Key Laboratory of Biomechanics and Mechanobiology (Beihang University), Ministry of Education, Beijing Advanced Innovation Center for Biomedical Engineering, School of Biological Science and Medical Engineering, Beihang University, Beijing 100083, China
| | - Zengsheng Chen
- Key Laboratory of Biomechanics and Mechanobiology (Beihang University), Ministry of Education, Beijing Advanced Innovation Center for Biomedical Engineering, School of Biological Science and Medical Engineering, Beihang University, Beijing 100083, China.
| | - Yubo Fan
- Key Laboratory of Biomechanics and Mechanobiology (Beihang University), Ministry of Education, Beijing Advanced Innovation Center for Biomedical Engineering, School of Biological Science and Medical Engineering, Beihang University, Beijing 100083, China.
| |
Collapse
|
8
|
Zhussupbekov M, Méndez Rojano R, Wu WT, Antaki JF. von Willebrand factor unfolding mediates platelet deposition in a model of high-shear thrombosis. Biophys J 2022; 121:4033-4047. [PMID: 36196057 PMCID: PMC9675031 DOI: 10.1016/j.bpj.2022.09.040] [Citation(s) in RCA: 11] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/08/2022] [Revised: 06/21/2022] [Accepted: 09/27/2022] [Indexed: 11/30/2022] Open
Abstract
Thrombosis under high-shear conditions is mediated by the mechanosensitive blood glycoprotein von Willebrand factor (vWF). vWF unfolds in response to strong flow gradients and facilitates rapid recruitment of platelets in flowing blood. While the thrombogenic effect of vWF is well recognized, its conformational response in complex flows has largely been omitted from numerical models of thrombosis. We recently presented a continuum model for the unfolding of vWF, where we represented vWF transport and its flow-induced conformational change using convection-diffusion-reaction equations. Here, we incorporate the vWF component into our multi-constituent model of thrombosis, where the local concentration of stretched vWF amplifies the deposition rate of free-flowing platelets and reduces the shear cleaning of deposited platelets. We validate the model using three benchmarks: in vitro model of atherothrombosis, a stagnation point flow, and the PFA-100, a clinical blood test commonly used for screening for von Willebrand disease (vWD). The simulations reproduced the key aspects of vWF-mediated thrombosis observed in these experiments, such as the thrombus location, thrombus growth dynamics, and the effect of blocking platelet-vWF interactions. The PFA-100 simulations closely matched the reported occlusion times for normal blood and several hemostatic deficiencies, namely, thrombocytopenia, vWD type 1, and vWD type 3. Overall, this multi-constituent model of thrombosis enables macro-scale 3D simulations of thrombus formation in complex geometries over a wide range of shear rates and accounts for qualitative and quantitative hemostatic deficiencies in patient blood.
Collapse
Affiliation(s)
- Mansur Zhussupbekov
- Meinig School of Biomedical Engineering, Cornell University, Ithaca, New York
| | | | - Wei-Tao Wu
- Department of Aerospace Science and Technology, Nanjing University of Science and Technology, Nanjing, China
| | - James F Antaki
- Meinig School of Biomedical Engineering, Cornell University, Ithaca, New York.
| |
Collapse
|
9
|
Tobin N, Manning KB. Toward modeling thrombosis and thromboembolism in laminar and turbulent flow regimes. INTERNATIONAL JOURNAL FOR NUMERICAL METHODS IN BIOMEDICAL ENGINEERING 2022; 38:e3638. [PMID: 36220632 PMCID: PMC9556977 DOI: 10.1002/cnm.3638] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/10/2022] [Revised: 06/06/2022] [Accepted: 07/19/2022] [Indexed: 06/16/2023]
Abstract
Thrombosis and thromboembolism are deadly risk factors in blood-contacting biomedical devices, and in-silico models of thrombosis are attractive tools to understand the mechanics of these processes, though the simulation of thromboembolism remains underdeveloped. The purpose of this study is to modify an existing computational thrombosis model to allow for thromboembolism and to investigate the behavior of the modified model at a range of flow rates. The new and existing models are observed to lead to similar predictions of thrombosis in a canonical backward-facing step geometry across flow rates, and neither model predicts thrombosis in a turbulent flow. Simulations are performed by increasing flow rates in the case of a clot formed at lower flow to induce embolization. While embolization is observed, most of the clot breakdown is by shear rather than by breakup and subsequent transport of clotted material, and further work is required in the formulation and validation of embolization. This model provides a framework to further investigate thromboembolization.
Collapse
Affiliation(s)
- Nicolas Tobin
- Department of Biomedical Engineering, The Pennsylvania State University, University Park, Pennsylvania, 16802, USA
| | - Keefe B. Manning
- Department of Biomedical Engineering, The Pennsylvania State University, University Park, Pennsylvania, 16802, USA
- Department of Surgery, Penn State Hershey Medical Center, Hershey, Pennsylvania, 17033, USA
| |
Collapse
|
10
|
Effect of Risk-Focused Diversified Safety Management Mode in Patients with Major Artery Stent Implantation. Emerg Med Int 2022; 2022:1284254. [PMID: 36212997 PMCID: PMC9546671 DOI: 10.1155/2022/1284254] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/03/2022] [Revised: 08/28/2022] [Accepted: 09/02/2022] [Indexed: 11/18/2022] Open
Abstract
Background Intracranial atherosclerotic stenosis (ICAS) causes a series of neurological symptoms, such as vertigo, impaired consciousness, limb weakness, ataxia, dysphagia, ocular motility disorders, and visual impairment. With the improvement of people's living standards, there are higher requirements for nursing care. Nursing, as an indispensable part of medical care, is closely related to achieving the goal of patient's safety and the overall quality of nurses, quality of care, and nursing management methods. Objective To explore the effect of risk-centered diversified safety management in patients undergoing aortic stenting. Methods Eighty patients with cerebral infarction were selected and treated with percutaneous transluminal angioplasty and stent implantation (PTAS). Then they were divided into a control group (40 cases) with routine monitoring and an experimental group (40 cases) with risk-focused intervention of a diversified safety management model according to the mode of care. Patient satisfaction and blood index test results were compared after the intervention. Results Patients in the experimental group had 6 falls, 3 bed falls, 3 phlebitis, 4 tube slips, and 10 deep vein thrombosis, all significantly fewer than those in the control group. Thirty-eight patients in the experimental group expressed satisfaction with safe management, which was substantially better than the control group (P < 0.05). The levels of tissue plasminogen activator (tPA), plasminogen activator inhibitor-1 (PA1-1), and von Willebrand factor (vWF) in the experimental group were (13.5 ± 1.3) ng/mL, (60.1 ± 9.9) ng/mL, and (2.1 ± 0.2), respectively, which were substantially lower than those in the control group ((14.6 ± 2.4) ng/mL, (64.2 ± 10.7) ng/mL, and (2.8 ± 0.3)), respectively (P < 0.05). Conclusion The risk-centered diversified safety management model can effectively reduce the probability of adverse events in patients, improve patient satisfaction with nursing services, and promote faster postoperative recovery, which has clinical application value.
Collapse
|
11
|
Pham OL, Feher SE, Nguyen QT, Papavassiliou DV. Computations of the shear stresses distribution experienced by passive particles as they circulate in turbulent flow: A case study for vWF protein molecules. PLoS One 2022; 17:e0273312. [PMID: 36037218 PMCID: PMC9423662 DOI: 10.1371/journal.pone.0273312] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/19/2022] [Accepted: 08/07/2022] [Indexed: 11/19/2022] Open
Abstract
The stress distribution along the trajectories of passive particles released in turbulent flow were computed with the use of Lagrangian methods and direct numerical simulations. The flow fields selected were transitional Poiseuille-Couette flow situations found in ventricular assist devices and turbulent flows at conditions found in blood pumps. The passive particle properties were selected to represent molecules of the von Willebrand factor (vWF) protein. Damage to the vWF molecule can cause disease, most often related to hemostasis. The hydrodynamic shear stresses along the trajectories of the particles were calculated and the changes in the distribution of stresses were determined for proteins released in different locations in the flow field and as a function of exposure time. The stress distributions indicated that even when the average applied stress was within a safe operating regime, the proteins spent part of their trajectories in flow areas of damaging stress. Further examination showed that the history of the distribution of stresses applied on the vWF molecules, rather than the average, should be used to evaluate hydrodynamically-induced damage.
Collapse
Affiliation(s)
- Oanh L. Pham
- School of Chemical, Biological and Materials Engineering, The University of Oklahoma, Norman, Oklahoma, United States of America
| | - Samuel E. Feher
- School of Chemical, Biological and Materials Engineering, The University of Oklahoma, Norman, Oklahoma, United States of America
| | - Quoc T. Nguyen
- School of Chemical, Biological and Materials Engineering, The University of Oklahoma, Norman, Oklahoma, United States of America
| | - Dimitrios V. Papavassiliou
- School of Chemical, Biological and Materials Engineering, The University of Oklahoma, Norman, Oklahoma, United States of America
- * E-mail:
| |
Collapse
|
12
|
Distribution and history of extensional stresses on vWF surrogate molecules in turbulent flow. Sci Rep 2022; 12:171. [PMID: 34997036 PMCID: PMC8742075 DOI: 10.1038/s41598-021-04034-9] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/20/2021] [Accepted: 12/13/2021] [Indexed: 11/17/2022] Open
Abstract
The configuration of proteins is critical for their biochemical behavior. Mechanical stresses that act on them can affect their behavior leading to the development of decease. The von Willebrand factor (vWF) protein circulating with the blood loses its efficacy when it undergoes non-physiological hemodynamic stresses. While often overlooked, extensional stresses can affect the structure of vWF at much lower stress levels than shear stresses. The statistical distribution of extensional stress as it applies on models of the vWF molecule within turbulent flow was examined here. The stress on the molecules of the protein was calculated with computations that utilized a Lagrangian approach for the determination of the molecule trajectories in the flow filed. The history of the stresses on the proteins was also calculated. Two different flow fields were considered as models of typical flows in cardiovascular mechanical devises, one was a Poiseuille flow and the other was a Poiseuille–Couette flow field. The data showed that the distribution of stresses is important for the design of blood flow devices because the average stress can be below the critical value for protein damage, but tails of the distribution can be outside the critical stress regime.
Collapse
|
13
|
Foster KM, Papavassiliou DV, O’Rear EA. Elongational Stresses and Cells. Cells 2021; 10:2352. [PMID: 34572002 PMCID: PMC8471242 DOI: 10.3390/cells10092352] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/13/2021] [Revised: 09/04/2021] [Accepted: 09/04/2021] [Indexed: 01/03/2023] Open
Abstract
Fluid forces and their effects on cells have been researched for quite some time, especially in the realm of biology and medicine. Shear forces have been the primary emphasis, often attributed as being the main source of cell deformation/damage in devices like prosthetic heart valves and artificial organs. Less well understood and studied are extensional stresses which are often found in such devices, in bioreactors, and in normal blood circulation. Several microfluidic channels utilizing hyperbolic, abrupt, or tapered constrictions and cross-flow geometries, have been used to isolate the effects of extensional flow. Under such flow cell deformations, erythrocytes, leukocytes, and a variety of other cell types have been examined. Results suggest that extensional stresses cause larger deformation than shear stresses of the same magnitude. This has further implications in assessing cell injury from mechanical forces in artificial organs and bioreactors. The cells' greater sensitivity to extensional stress has found utility in mechanophenotyping devices, which have been successfully used to identify pathologies that affect cell deformability. Further application outside of biology includes disrupting cells for increased food product stability and harvesting macromolecules for biofuel. The effects of extensional stresses on cells remains an area meriting further study.
Collapse
Affiliation(s)
| | | | - Edgar A. O’Rear
- Department of Chemical, Biological and Materials Engineering, University of Oklahoma, Norman, OK 73019, USA; (K.M.F.); (D.V.P.)
| |
Collapse
|