1
|
Yasuda M, Mizutani K, Onishi K, Onishi N, Fujita K, Ueno M, Okamura A, Iwanaga Y, Sakaguchi G, Nakazawa G. Hemodynamic effect of supra-annular implantation of SAPIEN 3 balloon expandable valve. Cardiovasc Interv Ther 2025; 40:133-143. [PMID: 39240505 PMCID: PMC11723897 DOI: 10.1007/s12928-024-01040-2] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/29/2024] [Accepted: 08/19/2024] [Indexed: 09/07/2024]
Abstract
The hemodynamic impact of the implantation depth for balloon-expandable valves is under-investigated, especially with higher implantation techniques. We assessed the hemodynamic performance of supra-annular SAPIEN 3 valve implantation. This retrospective study involved consecutive patients who underwent transcatheter aortic valve replacement (TAVR) using the SAPIEN 3. The device implantation depth and transcatheter heart valve (THV) leaflet-nadir position were angiographically analyzed, and supra-annular implantation was defined as a higher leaflet-nadir position than the original annular line. The Doppler hemodynamic status was evaluated at patient discharge. Among 184 patients, 120 (65%) underwent supra-annular implantation, and their mean implantation depth was significantly lower than that of intra-annular implantation (1.1 vs. 5.2 mm, p < 0.001). No patients developed valve embolization or coronary occlusion, and none required the TAV-in-TAV procedure. Two (1.6%) patients in the supra-annular implantation group had a mild or greater paravalvular leak. Echocardiography demonstrated that supra-annular implantation had better hemodynamic performance, showing a larger indexed effective orifice area (iEOA) compared with intra-annular implantation (1.09 vs. 0.97 cm2/m2, p < 0.01). There was a weak but negative correlation between the implantation depth and iEOA (r = - 0.27, p < 0.01). Moderate or severe prosthesis-patient mismatch (PPM) was found in 35.9% of the intra-annular group and 9.2% of supra-annular of the supra-annular group (p < 0.01). In the multivariable analysis, supra-annular implantation was an independent predictor of better THV function (iEOA > 0.85). Supra-annular SAPIEN 3 implantation provides beneficial hemodynamic effects and reduces the PPM risk.
Collapse
Affiliation(s)
- Masakazu Yasuda
- Division of Cardiology, Sakurabashi Watanabe Advanced Healthcare Hospital, OSAKA, Japan
- Division of Cardiology, Department of Internal Medicine, Kindai University Faculty of Medicine, OSAKA, Japan
| | - Kazuki Mizutani
- Department of Cardiology, Sapporo Cardio vascular Clinic, 8-1, Kita 49 jyo, Higashi 16 jyo, Higashi-ku, Sapporo, 007-0849, Japan.
| | - Kyohei Onishi
- Division of Cardiology, Department of Internal Medicine, Kindai University Faculty of Medicine, OSAKA, Japan
| | - Naoko Onishi
- Division of Cardiology, Department of Internal Medicine, Kindai University Faculty of Medicine, OSAKA, Japan
| | - Kosuke Fujita
- Division of Cardiology, Department of Internal Medicine, Kindai University Faculty of Medicine, OSAKA, Japan
| | - Masafumi Ueno
- Division of Cardiology, Department of Internal Medicine, Kindai University Faculty of Medicine, OSAKA, Japan
| | - Atsushi Okamura
- Division of Cardiology, Sakurabashi Watanabe Advanced Healthcare Hospital, OSAKA, Japan
| | - Yoshitaka Iwanaga
- Division of Cardiology, Sakurabashi Watanabe Advanced Healthcare Hospital, OSAKA, Japan
| | - Genichi Sakaguchi
- Department of Cardiovascular Surgery, Kindai University Faculty of Medicine, OSAKA, Japan
| | - Gaku Nakazawa
- Division of Cardiology, Department of Internal Medicine, Kindai University Faculty of Medicine, OSAKA, Japan
| |
Collapse
|
2
|
Rao K, Baer A, Bapat VN, Piazza N, Hansen P, Prendergast B, Bhindi R. Lifetime management considerations to optimise transcatheter aortic valve implantation: a practical guide. EUROINTERVENTION 2024; 20:e1493-e1504. [PMID: 39676551 PMCID: PMC11626398 DOI: 10.4244/eij-d-24-00332] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/08/2024] [Accepted: 08/30/2024] [Indexed: 12/17/2024]
Abstract
Transcatheter aortic valve implantation (TAVI) is a safe and effective procedure for the treatment of aortic stenosis. With the recently broadened indications, there is a larger cohort of patients likely to outlive their first transcatheter heart valve (THV). This review discusses relevant lifetime planning considerations, focusing on the utility of preprocedural computed tomography imaging to help implanters future-proof their patients who are likely to outlive their first valve. The initial priority is to optimise the index procedure by maximising THV haemodynamic function and durability. This involves maximising the effective orifice area, minimising the risk of new pacemaker implantation, reducing paravalvular regurgitation, and preventing coronary obstruction and annular rupture. In patients requiring a second valve procedure, a significant proportion will require a TAVI-in-TAVI, and implanters should consider the key priorities for a redo procedure, including the increased risks of patient-prosthesis mismatch and conduction abnormalities, promoting coronary reaccessibility, and preventing coronary obstruction and sinus sequestration. Careful planning can identify potential hurdles as well as predict the feasibility and likely outcomes of redo-TAVI, to help individualise care over the lifetime of each patient.
Collapse
Affiliation(s)
- Karan Rao
- Royal North Shore Hospital, Sydney, Australia
- University of Sydney, Sydney, Australia
| | | | | | - Nicolo Piazza
- McGill University Health Centre, McGill University, Montreal, QC, Canada
| | - Peter Hansen
- Royal North Shore Hospital, Sydney, Australia
- North Shore Private Hospital, Sydney, Australia
| | - Bernard Prendergast
- Department of Cardiology, St Thomas' Hospital, London, United Kingdom
- Heart, Thoracic and Vascular Institute, Cleveland Clinic, London, United Kingdom
| | - Ravinay Bhindi
- Royal North Shore Hospital, Sydney, Australia
- University of Sydney, Sydney, Australia
| |
Collapse
|
3
|
Eckel C, Kim WK, Schlüter J, Renker M, Bargon S, Grothusen C, Elsässer A, Dohmen G, Choi YH, Charitos EI, Hamm CW, Sossalla S, Möllmann H, Blumenstein J. Impact of Accidental High or Low Implantation Depth on Peri-Procedural Outcomes after Implantation with the Self-Expanding ACURATE neo2. J Clin Med 2024; 13:5342. [PMID: 39274553 PMCID: PMC11396697 DOI: 10.3390/jcm13175342] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/22/2024] [Revised: 08/15/2024] [Accepted: 08/24/2024] [Indexed: 09/16/2024] Open
Abstract
Background: Precise implantation could play a crucial role in the technical success of transcatheter aortic valve replacement (TAVR) for some prostheses. The impact of an accidental implantation depth (ID) outside the recommended range has not been assessed for the ACURATE neo2 (NEO2). Methods: Data from 1839 patients with severe native aortic stenosis treated with the NEO2 prosthesis were evaluated. We compared the results of prostheses implanted in an ID both inside and outside the recommendations. The outcome assessment followed the Valve Academic Research Consortium-3 criteria. Results: Patients were retrospectively divided into high (<3 mm; n = 412), optimal (3-7 mm; n = 1236), and low (>7 mm; n = 169) implantations. Technical success (94.7% vs. 94.7% vs. 91.7%, p = 0.296) and device success were high (90.1% vs. 89.3% vs. 84.6%, p = 0.112) without differences between groups. Rates of relevant paravalvular regurgitation (PVL; >mild or VinV due to PVL) were comparable (1.2% vs. 1.8% vs. 1.2%, p = 0.759). Even when hemodynamics were superior in the high-implantation group, with greater iEOA (1.01 cm2/m2 vs. 0.95 cm2/m2 vs. 0.92 cm2/m2, p < 0.001), spontaneous embolization or after post-dilatation was more common. Low implantation was associated with a higher rate of associated pacemaker implantation (PPI) (6.1% vs. 8.8% vs. 14.8%, p = 0.001). Conclusions: Implantation with the ACURATE neo2 showed excellent hemodynamic results, including low gradients and a small number of relevant PVL, in line with a high technical success rate that was irrespective of the ID. A favorable outcome can also be achieved in accidental low or high positions. Low implantation was associated with a higher rate of associated pacemaker implantation. Deliberately high implantation should be avoided due to the risk of embolization.
Collapse
Affiliation(s)
- Clemens Eckel
- Department of Cardiology, St. Johannes Hospital, 44137 Dortmund, Germany
- School VI-School of Medicine and Health Sciences, Carl von Ossietzky Universität Oldenburg, 26129 Oldenburg, Germany
| | - Won-Keun Kim
- Department of Cardiology, Kerckhoff Heart Center, 61231 Bad Nauheim, Germany
- Department of Cardiology, Justus-Liebig University of Giessen, 35390 Giessen, Germany
| | - Judith Schlüter
- Department of Cardiology, St. Johannes Hospital, 44137 Dortmund, Germany
| | - Matthias Renker
- Department of Cardiology, Kerckhoff Heart Center, 61231 Bad Nauheim, Germany
- Department of Cardiac Surgery, Kerckhoff Heart Center, 61231 Bad Nauheim, Germany
| | - Sophie Bargon
- Department of Cardiology, St. Johannes Hospital, 44137 Dortmund, Germany
| | - Christina Grothusen
- Department of Cardiology, St. Johannes Hospital, 44137 Dortmund, Germany
- Department of Cardiac Surgery, University of Kiel, 24118 Kiel, Germany
| | - Albrecht Elsässer
- School VI-School of Medicine and Health Sciences, Carl von Ossietzky Universität Oldenburg, 26129 Oldenburg, Germany
| | - Guido Dohmen
- Department of Cardiac Surgery, St. Johannes Hospital, 44137 Dortmund, Germany
| | - Yeong-Hoon Choi
- Department of Cardiac Surgery, Kerckhoff Heart Center, 61231 Bad Nauheim, Germany
| | | | - Christian W Hamm
- Department of Cardiology, Kerckhoff Heart Center, 61231 Bad Nauheim, Germany
- Department of Cardiology, Justus-Liebig University of Giessen, 35390 Giessen, Germany
| | - Samuel Sossalla
- Department of Cardiology, Kerckhoff Heart Center, 61231 Bad Nauheim, Germany
- Department of Cardiology, Justus-Liebig University of Giessen, 35390 Giessen, Germany
| | - Helge Möllmann
- Department of Cardiology, St. Johannes Hospital, 44137 Dortmund, Germany
| | - Johannes Blumenstein
- Department of Cardiology, St. Johannes Hospital, 44137 Dortmund, Germany
- School VI-School of Medicine and Health Sciences, Carl von Ossietzky Universität Oldenburg, 26129 Oldenburg, Germany
| |
Collapse
|
4
|
Eckel C, Kim WK, Sötemann D, Grothusen C, Tiyerili V, Dohmen G, Renker M, Charitos EI, Hamm CW, Choi YH, Elsässer A, Möllmann H, Blumenstein J. ACURATE neo2 Versus SAPIEN 3 Ultra Transcatheter Heart Valve in Severe Aortic Valve Calcification: A Propensity-Matched Analysis. Circ Cardiovasc Interv 2024; 17:e013608. [PMID: 38529637 DOI: 10.1161/circinterventions.123.013608] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/10/2023] [Accepted: 02/08/2024] [Indexed: 03/27/2024]
Abstract
BACKGROUND Comparative data on transcatheter self-expanding ACURATE neo2 (NEO2) and balloon-expandable SAPIEN 3 Ultra prostheses in technically challenging anatomy of severe aortic valve calcified aortic annuli are scarce. METHODS A total of 1987 patients with severe native aortic stenosis treated with the self-expanding NEO2 (n=1457) or balloon-expandable SAPIEN 3 Ultra (n=530) from January 2017 to April 2023 were evaluated. The primary end point was procedural outcome according to the Valve Academic Research Consortium 3 definitions. Propensity matching defined 219 pairs with severe calcification (calcium density cutoff, 758 AU/cm2) of the native aortic valve. RESULTS Technical success (90.4% versus 91.8%; risk difference, 1.4% [95% CI, -4.4 to -7.2]; P=0.737) and device success at 30 days (80.8% versus 75.8%; risk difference, -5.0% [95% CI, -13.2 to 3.1]; P=0.246) were comparable between NEO2 and SAPIEN 3 Ultra. The rate of severe prosthesis-patient mismatch (1.1% versus 10.1%; risk difference, 10.0% [95% CI, 4.0-13.9]; P<0.001) and mean transvalvular gradient ≥20 mm Hg (2.8% versus 14.3%; risk difference, 11.5% [95% CI, 5.8-17.1]; P<0.001) was lower with NEO2. The rate of more-than-mild paravalvular leakage or valve-in-valve due to paravalvular leakage was significantly higher (6.2% versus 0.0%; risk difference, 6.2% [95% CI, -10.1 to -2.7]; P=0.002), and there was a tendency for a higher rate of device embolization or migration (1.8% versus 0.0%; risk difference, -1.8% [95% CI, -4.1 to 0.4]; P=0.123) with NEO2. Multivarate regression revealed no independent impact of transcatheter heart valve selection on device success (odds ratio, 0.93 [95% CI, 0.48-1.77]; P=0.817). CONCLUSIONS In patients with severely calcified annuli, supraannular implantation of NEO2 showed hemodynamic advantages. Nevertheless, NEO2 was associated with a higher incidence of relevant paravalvular leakage and a numerically higher rate of device embolization than SAPIEN 3 Ultra in this particular patient group.
Collapse
Affiliation(s)
- Clemens Eckel
- Department of Cardiology, St. Johannes Hospital, Dortmund, Germany (C.E., D.S., C.G., V.T., H.M., J.B.)
- Department of Cardiology, University of Oldenburg, Germany (C.E., A.E., J.B.)
| | - Won-Keun Kim
- Departments of Cardiology (W.-K.K., M.R.), Kerckhoff Heart Center, Bad Nauheim, Germany
- Cardiac Surgery (W.-K.K., M.R., E.I.C., Y.-H.C.), Kerckhoff Heart Center, Bad Nauheim, Germany
| | - Dagmar Sötemann
- Department of Cardiology, St. Johannes Hospital, Dortmund, Germany (C.E., D.S., C.G., V.T., H.M., J.B.)
| | - Christina Grothusen
- Department of Cardiology, St. Johannes Hospital, Dortmund, Germany (C.E., D.S., C.G., V.T., H.M., J.B.)
- Department of Cardiac Surgery, University of Kiel, Germany (C.G.)
| | - Vedat Tiyerili
- Department of Cardiology, St. Johannes Hospital, Dortmund, Germany (C.E., D.S., C.G., V.T., H.M., J.B.)
| | - Guido Dohmen
- Department of Cardiac Surgery, St. Johannes Hospital, Dortmund, Germany (G.D.)
| | - Matthias Renker
- Departments of Cardiology (W.-K.K., M.R.), Kerckhoff Heart Center, Bad Nauheim, Germany
- Cardiac Surgery (W.-K.K., M.R., E.I.C., Y.-H.C.), Kerckhoff Heart Center, Bad Nauheim, Germany
| | - Efstratios I Charitos
- Cardiac Surgery (W.-K.K., M.R., E.I.C., Y.-H.C.), Kerckhoff Heart Center, Bad Nauheim, Germany
| | - Christian W Hamm
- Department of Cardiology, University of Giessen, Germany (C.W.H.)
- German Center for Cardiovascular Research, Partner Site RheinMain, Bad Nauheim, Germany (C.W.H.)
| | - Yeong-Hoon Choi
- Cardiac Surgery (W.-K.K., M.R., E.I.C., Y.-H.C.), Kerckhoff Heart Center, Bad Nauheim, Germany
| | - Albrecht Elsässer
- Department of Cardiology, University of Oldenburg, Germany (C.E., A.E., J.B.)
| | - Helge Möllmann
- Department of Cardiology, St. Johannes Hospital, Dortmund, Germany (C.E., D.S., C.G., V.T., H.M., J.B.)
| | - Johannes Blumenstein
- Department of Cardiology, St. Johannes Hospital, Dortmund, Germany (C.E., D.S., C.G., V.T., H.M., J.B.)
- Department of Cardiology, University of Oldenburg, Germany (C.E., A.E., J.B.)
| |
Collapse
|
5
|
Möllmann H, Linke A, Nombela-Franco L, Sluka M, Francisco Oteo Dominguez J, Montorfano M, Kim WK, Arnold M, Vasa-Nicotera M, Fichtlscherer S, Conradi L, Camuglia A, Bedogni F, Kohli K, Manoharan G. Valve Hemodynamics by Valve Size and 1-Year Survival Following Implantation of the Portico Valve in the Multicenter CONFIDENCE Registry. STRUCTURAL HEART : THE JOURNAL OF THE HEART TEAM 2024; 8:100226. [PMID: 38283573 PMCID: PMC10818152 DOI: 10.1016/j.shj.2023.100226] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 01/04/2023] [Revised: 08/09/2023] [Accepted: 08/31/2023] [Indexed: 01/30/2024]
Abstract
Background The CONtrolled delivery For ImproveD outcomEs with cliNiCal Evidence registry was initiated to characterize the clinical safety and device performance from experienced transcatheter aortic valve implantation (TAVI) centers in Europe and Australia that use the Portico valve to treat patients with severe aortic stenosis. We herein report for the first time the valve performance at 30-day across all implanted valve sizes and the 1-year survival from this registry. Methods This was a prospective, multicenter, single-arm observational clinical investigation of patients clinically indicated for implantation of a Portico valve in experienced TAVI centers. Patients were treated with a commercially available valve (size 23, 25, 27, or 29 mm) using either the first-generation delivery system (DS) (n = 501) or the second-generation (FlexNav) DS (n = 500). Adverse events were adjudicated by an independent clinical events committee according to Valve Academic Research Consortium-2 criteria. Echocardiographic outcomes were assessed at 30 days by an independent core laboratory, and a survival check was performed at 1 year. Results We enrolled 1001 patients (82.0 years, 62.5% female, 63.7% New York Heart Association functional class III/IV at baseline) from 27 clinical sites in 8 countries across Europe and one site in Australia. Implantation of a single valve was successful in 97.5% of subjects. Valve hemodynamics at 30 days were substantially improved relative to baseline, with large aortic valve areas and low mean gradients across all implanted valve sizes (aortic valve areas were 1.7 ± 0.4, 1.7 ± 0.5, 1.8 ± 0.5, and 2.0 ± 0.5 cm2, and mean gradients were 7.0 ± 2.7, 7.5 ± 4.7, 7.3 ± 3.3, and 6.4 ± 3.3 mmHg for 23, 25, 27, and 29 mm valve sizes, respectively). Across all implanted valve sizes, most patients (77.1%) had no patient-prosthesis mismatch. Death from any cause within 1 year occurred in 13.7% of the patients in the first-generation DS group as compared with 11.0% in the second-generation DS group (p = 0.2). Conclusions The Portico valve demonstrated excellent hemodynamic performance across all valve sizes in a large cohort of subjects implanted in experienced TAVI centers. One-year survival rates were favorable when using both the first-generation and second-generation (FlexNav) DSs in this high-risk cohort. ClinicalTrialsgov Identifier NCT03752866.
Collapse
Affiliation(s)
- Helge Möllmann
- Department of Cardiology, St. Johannes Hospital, Dortmund, Germany
| | - Axel Linke
- Department of Internal Medicine/Cardiology, University Hospital of the Technical University of Dresden, Heart Center Dresden, Dresden, Germany
| | - Luis Nombela-Franco
- Cardiovascular Institute, Hospital Clinico San Carlos, IdISSC, Madrid, Spain
| | - Martin Sluka
- Department of Medicine-Cardiology, University Hospital Olomouc, Olomouc, Czech Republic
| | | | - Matteo Montorfano
- Interventional Cardiology Unit IRCCS San Raffaele Scientific Institute, Milan, Italy
| | - Won-Keun Kim
- Kerckhoff Heart and Thorax Centre, Bad Nauheim, Germany
| | - Martin Arnold
- Department of Cardiology, Friedrich-Alexander-Universität Erlangen Nuremberg, Erlangen, Germany
| | - Mariuca Vasa-Nicotera
- Department of Cardiology, University Hospital of the Johann Wolfgang Goethe University Frankfurt, Frankfurt, Germany
| | - Stephan Fichtlscherer
- Department of Cardiology, University Hospital of the Johann Wolfgang Goethe University Frankfurt, Frankfurt, Germany
| | - Lenard Conradi
- Department of Cardiovascular Surgery, University Heart and Vascular Center, Hamburg, Germany
| | - Anthony Camuglia
- University of Queensland, Brisbane, Australia
- The Wesley Hospital, Brisbane, Australia
| | | | - Keshav Kohli
- Abbott Laboratories, Santa Clara, California, USA
| | | |
Collapse
|
6
|
Kornyeva A, Burri M, Lange R, Ruge H. Self-expanding vs. balloon-expandable transcatheter heart valves in small aortic annuli. Front Cardiovasc Med 2023; 10:1175246. [PMID: 37600053 PMCID: PMC10435261 DOI: 10.3389/fcvm.2023.1175246] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/27/2023] [Accepted: 06/27/2023] [Indexed: 08/22/2023] Open
Abstract
Background Clinical consequences of prosthesis-patient mismatch (PPM) after transcatheter aortic valve replacement (TAVR) is currently in the focus of clinical research. Patients with small aortic annulus are at higher risk to display PPM. Data on incidence and clinical consequences of PPM after TAVR with either balloon-expandable (BEV) or self-expanding (SEV) transcatheter heart valves in small aortic annulus are sparse. Methods Patients with small aortic annulus (perimeter < 72 mm or aortic annulus area < 400 mm2) who underwent BEV or SEV with contemporary transcatheter heart valve types were identified from the institutional TAVR database. Propensity score matching was applied for imbalanced baseline characteristics between patients undergoing BEV or SEV. Echocardiography and clinical follow-up beyond 3 years was reported following VARC-3 recommendations. Primary endpoint was the incidence of pre-discharge PPM and its association with 3-year mortality. Results From a total of 507 patients with small aortic annulus, 192 matched patient pairs with SEV or BEV were identified. Mean age was 81 ± 7 (SEV) vs. 81 ± 6 (BEV) years (p = 0.5), aortic annulus perimeter was 69 ± 3 vs.69 ± 3 mm, (p = 0.8), annulus area was 357 ± 27 vs.357 ± 27 mm2 (p = 0.8), and EuroScore II was 5.8 ± 6.6 vs.5.7 ± 7.2 (p = 0.9). SEV resulted in less moderate (20% vs. 31%, p < 0.001) and severe pre-discharge PPM (9% vs.18%, p < 0.001) compared to BEV. At discharge (7 ± 4 vs. 12 ± 9 mmHg, p = 0.003) and at 1-year follow-up (7 ± 5 vs.13 ± 3 mmHg, p < 0.001), SEV displayed lower mean gradients compared to BEV. Estimated survival after SEV was 85% (95% confidence interval (CI): 80%-90%) at 1 year, 80% (95% CI: 75%-86%) at 2 years, and 71% (95% CI: 65%-78%) at 3 years; estimated survival after BEV was 87% (95% CI: 82%-92%) at 1 year, 81% (95% CI: 75%-86%) at 2 years, and 72% (95% CI: 66%-79%) at 3 years, with no significant difference among the groups (p = 0.9) Body surface area (OR: 1.35, p < 0.001), implantation of BEV (odds ratio (OR): 3.32, p < 0.001), and the absence of postdilatation (OR: 2.16, p < 0.001) were independent risk factors for any PPM. At 3 years, patients without PPM had a higher 3-year survival compared with patients with ≥moderate PPM (77% vs. 67%, p = 0.03). Conclusion BEV implantation in patients with small annulus was associated with a twofold higher incidence of pre-discharge severe PPM compared to SEV implantation. Survival at 3 years after TAVR was similar after BEV and SEV. However, patients with the absence of pre-discharge PPM had a higher 3-year survival compared to patients with ≥moderate PPM.
Collapse
Affiliation(s)
- Anastasiya Kornyeva
- Department of Cardiovascular Surgery, German Heart Centre Munich at the Technical University Munich, Munich, Germany
| | - Melchior Burri
- Department of Cardiovascular Surgery, German Heart Centre Munich at the Technical University Munich, Munich, Germany
| | - Rüdiger Lange
- Department of Cardiovascular Surgery, German Heart Centre Munich at the Technical University Munich, Munich, Germany
- Insure (Institute for Translational Cardiac Surgery), Department of Cardiovascular Surgery, German Heart Center Munich at the Technical University of Munich, Munich, Germany
- DZHK (German Center for Cardiovascular Research)-Partner Site Munich Heart Alliance, Munich, Germany
| | - Hendrik Ruge
- Department of Cardiovascular Surgery, German Heart Centre Munich at the Technical University Munich, Munich, Germany
- Insure (Institute for Translational Cardiac Surgery), Department of Cardiovascular Surgery, German Heart Center Munich at the Technical University of Munich, Munich, Germany
| |
Collapse
|
7
|
Tirado-Conte G, Rodés-Cabau J, Oteo JF, Pan M, Muñoz E, Witberg G, Cheema AN, Alpieri A, Lopez D, Amat-Santos IJ, Akodad M, Ojeda S, Serra V, Garcia-Blas S, Alfonso F, De Backer O, Asmarats L, Muñoz A, Hamdan A, Toggweiler S, Del Valle R, Salido L, Cruz-González I, Estevez-Loureiro R, Martin Alfaro LE, Gheorge L, Dabrowski M, Berenguer A, Arzamendi D, Saia F, Webb JG, Sondergaard L, Nombela-Franco L. Transcatheter aortic valve implantation in patients with extra-small aortic annuli. EUROINTERVENTION 2023; 19:e340-e351. [PMID: 37334654 PMCID: PMC10333922 DOI: 10.4244/eij-d-23-00011] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/05/2023] [Accepted: 05/01/2023] [Indexed: 06/20/2023]
Abstract
BACKGROUND A small aortic annulus (SAA) is a risk factor for prosthesis-patient mismatch (PPM) in patients undergoing surgical or transcatheter aortic valve implantation (TAVI). Data regarding TAVI in patients with extra-SAA are scarce. AIMS The aim of this study was to analyse the safety and efficacy of TAVI in patients with extra-SAA. METHODS A multicentre registry study including patients with extra-SAA (defined as an aortic annulus area <280 mm2 and/or perimeter <60 mm) undergoing TAVI was established. Primary efficacy and safety endpoints were defined as device success and early safety at 30 days, respectively, using the Valve Academic Research Consortium-3 criteria, and were analysed according to valve type: self-expanding (SEV) versus balloon-expandable (BEV). RESULTS A total of 150 patients were included, of which 139 (92.7%) were women, and 110 (73.3%) received an SEV. Intraprocedural technical success was 91.3%, with a higher rate in patients receiving an SEV (96.4% vs 77.5% with BEV; p=0.001). Overall, 30-day device success was 81.3%, (85.5% with SEV vs 70.0% with BEV; p=0.032). The primary safety endpoint occurred in 72.0% of patients (with no difference between groups; p=0.118). Severe PPM occurred in 12% (9.0% with SEV and 24.0% with BEV; p=0.039), with no impact on all-cause mortality, cardiovascular mortality, or heart failure readmission at 2-year follow-up. CONCLUSIONS TAVI is a safe and feasible treatment in patients with extra-SAA with a high rate of technical success. The use of SEV was associated with a lower rate of intraprocedural complications, higher device success at 30 days and better haemodynamic outcomes compared to BEV.
Collapse
Affiliation(s)
| | - Josep Rodés-Cabau
- Quebec Heart and Lung Institute, Laval University, Quebec, QC, Canada
| | - Juan F Oteo
- Department of Cardiology, Hospital Universitario Puerta de Hierro, Majadahonda, Spain
| | - Manuel Pan
- Hospital Universitario Reina Sofia, Córdoba, Spain and Universidad de Cordoba (IMIBIC), Córdoba, Spain
| | - Erika Muñoz
- CIBERCV Cardiology Department, Hospital Universitario Virgen de la Victoria, Málaga, Spain
| | - Guy Witberg
- Cardiology Department, Rabin Medical Center, Beilinson Hospital, Petah Tikva, Israel and The Faculty of Medicine, Tel Aviv University, Tel Aviv, Israel
| | - Asim N Cheema
- St Michael's Hospital, Toronto, ON, Canada
- Division of Cardiology, Southlake Regional Health Centre, Newmarket, ON, Canada
| | - Alberto Alpieri
- Quebec Heart and Lung Institute, Laval University, Quebec, QC, Canada
| | - Diego Lopez
- Hospital Clínico Universitario de Santiago, CIBERCV, Santiago, Spain
| | - Ignacio J Amat-Santos
- CIBERCV, Instituto de Ciencias del Corazón (ICICOR), Hospital Clínico Universitario de Valladolid, Valladolid, Spain
| | | | - Soledad Ojeda
- Hospital Universitario Reina Sofia, Córdoba, Spain and Universidad de Cordoba (IMIBIC), Córdoba, Spain
| | | | - Sergio Garcia-Blas
- Cardiology Department, Hospital Clínico Universitario de Valencia, Universitat de Valencia, INCLIVA, CIBERCV, Valencia, Spain
| | - Fernando Alfonso
- Department of Cardiology, Hospital Universitario La Princesa, IIS-IP, CIBERCV, Madrid, Spain
| | - Ole De Backer
- Department of Cardiology, Copenhagen University Hospital, Copenhagen, Denmark
| | | | - Antonio Muñoz
- CIBERCV Cardiology Department, Hospital Universitario Virgen de la Victoria, Málaga, Spain
| | - Ashraf Hamdan
- Cardiology Department, Rabin Medical Center, Beilinson Hospital, Petah Tikva, Israel and The Faculty of Medicine, Tel Aviv University, Tel Aviv, Israel
| | | | | | - Luisa Salido
- Cardiology Department, Hospital Ramón y Cajal, Madrid, Spain
| | - Ignacio Cruz-González
- Department of Cardiology, Complejo Asistencial Universitario Salamanca, CIBERCV, IBSAL, Salamanca, Spain
| | | | | | | | - Maciec Dabrowski
- Department of Interventional Cardiology and Angiology, National Institute of Cardiology, Warsaw, Poland
| | - Alberto Berenguer
- Cardiology Department, Hospital General Universitario de Valencia, Valencia, Spain
| | - Dabit Arzamendi
- Department of Cardiology, Hospital Universitario La Princesa, IIS-IP, CIBERCV, Madrid, Spain
| | - Francesco Saia
- Cardiology Unit, Cardio-Thoracic-Vascular Department, University Hospital of Bologna, Policlinico S. Orsola-Malpighi, Bologna, Italy
| | - John G Webb
- CIBERCV, Instituto de Ciencias del Corazón (ICICOR), Hospital Clínico Universitario de Valladolid, Valladolid, Spain
| | | | | |
Collapse
|
8
|
Mosleh W, Memon S, Hoover NE, Mather JF, Hagberg RC, Azemi T, Sadiq IR, Haider J, McMahon SR, Hashim S, McKay RG. Intermediate Follow-Up of Balloon-Expandable Versus Self-Expanding Transcatheter Aortic Valve Implantation in Patients With Small Aortic Annuli. Am J Cardiol 2023; 192:31-38. [PMID: 36731250 DOI: 10.1016/j.amjcard.2023.01.009] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/28/2022] [Revised: 12/16/2022] [Accepted: 01/03/2023] [Indexed: 02/04/2023]
Abstract
The clinical impact of prosthesis-patient mismatch (PPM) in patients with small aortic annuli who underwent transcatheter aortic valve (AV) implantation with either balloon-expandable (BE) or self-expanding (SE) valves remains controversial. We assessed in-hospital and intermediate clinical outcomes in 573 patients with transfemoral transcatheter AV implantation with a small AV annulus, defined as an AV annulus area ≤430 mm2. A total of 337 patients treated with a 23-mm BE valve (SAPIEN 3, Ultra) were compared with 236 patients treated with a 26-mm SE valve (Evolut series). Valve-in-valve cases were excluded, and late echo follow-up (mean 674 ± 438 days) was assessed in a subset of 292 patients (51.0%). Well-matched BE and SE cohorts did not differ with respect to major in-hospital outcomes, other than a borderline increase in vascular complications and composite bleeding in patients with SE. Patients with BE had a higher incidence of severe PPM on discharge echocardiography (16.9% vs 6.8%, p <0.002). The mean AV gradient at 30 days was higher for patients with BE (12.2 ± 4.2 vs 6.2 ± 7.9 mm Hg, p <0.001) and at late follow-up (14.0 ± 8.2 vs 7.2 ± 3.5 mm Hg, p <0.001). The follow-up left ventricular ejection fraction and incidence of >mild aortic insufficiency were similar. All-cause mortality for the 2 cohorts was similar, with an overall mean (95% confidence interval) survival time of 61.2 months (57.8 to 64.5; p = 0.98). There were no significant survival differences between combined patients with BE and SE with no, moderate, or severe PPM, with an overall mean (95% confidence interval) survival time of 32.5 (30.5 to 34.5) months combining valve types (p = 0.23). In conclusion, despite an increased incidence of PPM with higher mean AV gradients that persist on late echocardiography in the BE cohort, patients with BE and SE with small aortic annuli have similar clinical outcomes at intermediate follow-up. Moderate and severe PPM had no impact on survival at a mean follow-up of 32.5 months.
Collapse
Affiliation(s)
- Wassim Mosleh
- Department of Cardiology, Dartmouth-Hitchcock Medical Center, Lebanon, New Hampshire
| | | | | | - Jeff F Mather
- Department of Research Administration, Hartford Hospital, Hartford, Connecticut
| | - Robert C Hagberg
- Cardiac Surgery, Hartford Healthcare Heart and Vascular Institute, Hartford Hospital, Hartford, Connecticut
| | | | | | | | | | - Sabet Hashim
- Cardiac Surgery, Hartford Healthcare Heart and Vascular Institute, Hartford Hospital, Hartford, Connecticut
| | | |
Collapse
|
9
|
Alnajar A, Hamad N, Azhar MZ, Mousa Y, Arora Y, Lamelas J. Surgical versus transcatheter aortic valve replacement: Impact of patient-prosthesis mismatch on outcomes. J Card Surg 2022; 37:5388-5394. [PMID: 36378858 DOI: 10.1111/jocs.17217] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/24/2022] [Accepted: 10/29/2022] [Indexed: 11/16/2022]
Abstract
BACKGROUND The hemodynamics of most prosthetic valves are often inferior to that of the normal native valve, and a significant proportion of patients undergoing surgical (SAVR) or transcatheter aortic valve replacement (TAVR) have high residual transaortic pressure gradients due to prosthesis-patient mismatch (PPM). As the experience with TAVR has increased and long-term outcomes are reported, a close look at the PPM literature is required in light of new evidence. METHODS For this review, we searched the Embase, Medline, and Cochrane databases from 2000 to 2022. Articles reporting PPM as an outcome following aortic valve replacements were identified and reviewed. RESULTS The impact of PPM on clinical outcomes in aortic valve replacement has not been clear as multiple studies failed to report PPM incidence. However, the PPM outcomes after SAVR vary more widely than after TAVR, ranging from 8% to 80% in SAVR and from 24% to 35% in TAVR. Incidence of severe PPM following redo SAVR ranges from 2% to 9% and following valve-in-valve TAVR is from 14% to 33%, however, while PPM is higher in valve-in-valve TAVR, patients had better survival rates. CONCLUSIONS The gap between valve performance and clinical outcomes in SAVR and TAVR could be reduced by carefully selecting patients for either treatment option. Understanding predictors of PPM can add to the safety, effectiveness, and increased survival benefit of both SAVR and TAVR.
Collapse
Affiliation(s)
- Ahmed Alnajar
- Department of Surgery, Division of Cardiothoracic Surgery, University of Miami Miller School of Medicine, Miami, Florida, USA
| | - Naser Hamad
- Department of Surgery, Division of Cardiothoracic Surgery, University of Miami Miller School of Medicine, Miami, Florida, USA
| | | | - Yaseen Mousa
- Florida Atlantic University, Boca Raton, Florida, USA
| | - Yingyot Arora
- Department of Surgery, Division of Cardiothoracic Surgery, University of Miami Miller School of Medicine, Miami, Florida, USA
| | - Joseph Lamelas
- Department of Surgery, Division of Cardiothoracic Surgery, University of Miami Miller School of Medicine, Miami, Florida, USA
| |
Collapse
|
10
|
Daggubati R, Sabouni MA, Sattar Y. Accurate sizing of bicuspid valves for TAVR – where do we draw the line? ASIAINTERVENTION 2022; 8:71-73. [PMID: 36483284 PMCID: PMC9706738 DOI: 10.4244/aij-e-22-00005] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/17/2023]
Affiliation(s)
- Ramesh Daggubati
- Department of Cardiology, West Virginia University School of Medicine, Morgantown, WV, USA
| | | | - Yasar Sattar
- Department of Cardiology, West Virginia University School of Medicine, Morgantown, WV, USA
| |
Collapse
|
11
|
D'Onofrio A, Cibin G, Lorenzoni G, Tessari C, Bifulco O, Lombardi V, Bergonzoni E, Evangelista G, Pesce R, Taffarello P, Longinotti L, Ponzoni M, Gregori D, Gerosa G. Propensity-Weighted Comparison of Conventional Stented and Rapid-Deployment Aortic Bioprostheses. Curr Probl Cardiol 2022; 48:101426. [PMID: 36181783 DOI: 10.1016/j.cpcardiol.2022.101426] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/20/2022] [Accepted: 09/21/2022] [Indexed: 11/19/2022]
Abstract
OBJECTIVE Aim of this study was to compare early clinical and hemodynamic outcomes of Intuity and ME bioprostheses. METHODS A propensity score weighting approach was performed. Preoperative variables were defined according to EuroSCORE criteria and postoperative complications according to VARC-2 definitions. RESULTS We evaluated 375 patients who underwent SAVR with the two study devices. Intuity and ME were implanted in 252 (67.2%) and in 123 (32.8%) patients, respectively. There were no differences in terms of postoperative complications, including mortality (1% in each group; OR 0.46[0.05;4.21]). The incidence of pace-maker implantation was 6% and 5% in Intuity and ME groups, respectively (OR 0.53[0.27;1.07]). Intuity showed significantly lower gradients (Median mean gradients: 9mmHg vs. 14mmHg, p<0.001), larger effective orifice area index (1.13cm2/m2 vs. 1cm2/m2, p=0.007) and lower incidence of patient-prosthesis mismatch (7.1% vs. 22.8%, p=0.006). CONCLUSIONS The RD Intuity provides similar early clinical outcomes but shows significantly better hemodynamic performance compared to the ME valve.
Collapse
Affiliation(s)
| | - Giorgia Cibin
- Division of Cardiac Surgery, University of Padova, Padova, Italy
| | - Giulia Lorenzoni
- Unit of Biostatistics, Epidemiology and Public Health, University of Padova, Padova, Italy
| | - Chiara Tessari
- Division of Cardiac Surgery, University of Padova, Padova, Italy
| | - Olimpia Bifulco
- Division of Cardiac Surgery, University of Padova, Padova, Italy
| | | | - Emma Bergonzoni
- Division of Cardiac Surgery, University of Padova, Padova, Italy
| | | | - Rita Pesce
- Division of Cardiac Surgery, University of Padova, Padova, Italy
| | | | | | - Matteo Ponzoni
- Division of Cardiac Surgery, University of Padova, Padova, Italy
| | - Dario Gregori
- Unit of Biostatistics, Epidemiology and Public Health, University of Padova, Padova, Italy
| | - Gino Gerosa
- Division of Cardiac Surgery, University of Padova, Padova, Italy
| |
Collapse
|
12
|
Hemodynamic Performance of Two Current-Generation Transcatheter Heart Valve Prostheses in Severely Calcified Aortic Valve Stenosis. J Clin Med 2022; 11:jcm11154570. [PMID: 35956185 PMCID: PMC9369986 DOI: 10.3390/jcm11154570] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/28/2022] [Revised: 07/21/2022] [Accepted: 08/02/2022] [Indexed: 11/17/2022] Open
Abstract
BACKGROUND Treatment of severely calcified aortic valve stenosis is associated with a higher rate of paravalvular leakage (PVL) and permanent pacemaker implantation (PPI). We hypothesized that the self-expanding transcatheter heart valve (THV) prostheses Evolut Pro (EPro) is comparable to the balloon-expandable Sapien 3 (S3) regarding hemodynamics, PPI, and clinical outcome in these patients. METHODS From 2014 to 2019, all patients with very severe calcification of the aortic valve who received an EPro or an S3 THV were included. Propensity score matching was utilized to create two groups of 170 patients. RESULTS At discharge, there was significant difference in transvalvular gradients (EPro vs. S3) (dPmean 8.1 vs. 11.1 mmHg, p ≤ 0.001) and indexed effective orifice area (EOAi) (1.1 vs. 0.9, p ≤ 0.001), as well as predicted EOAi (1 vs. 0.9, p ≤ 0.001). Moderate patient prosthesis mismatch (PPM) was significantly lower in the EPro group (17.7% vs. 38%, p ≤ 0.001), as well as severe PPM (2.9% vs. 8.8%, p = 0.03). PPI and the PVL rate as well as stroke, bleeding, vascular complication, and 30-day mortality were comparable. CONCLUSIONS In patients with severely calcified aortic valves, both THVs performed similarly in terms of 30-day mortality, PPI rate, and PVL occurrence. However, patient prothesis mismatch was observed more often in the S3 group, which might be due to the intra-annular design.
Collapse
|
13
|
Artificial Intelligence-Based Spiral CT 3D Reconstruction in Transcatheter Aortic Valve Implantation. COMPUTATIONAL AND MATHEMATICAL METHODS IN MEDICINE 2022; 2022:5794681. [PMID: 35572825 PMCID: PMC9095377 DOI: 10.1155/2022/5794681] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 02/18/2022] [Revised: 04/07/2022] [Accepted: 04/09/2022] [Indexed: 11/18/2022]
Abstract
To evaluate the clinical application effect of spiral computed tomography (CT) three-dimensional (3D) reconstruction based on artificial intelligence in transcatheter aortic valve implantation (TAVI), a CT 3D reconstruction model based on deep convolutional neural networks (DCNN) was established in this research, which was compared with the model-based iterative reconstruction (MBIR) and used in clinical practice. Then, 62 patients with aortic stenosis (AS) who underwent TAVI surgery were recruited as the research objects. The accuracy, sensitivity, and specificity of the multislice spiral CT scan (MSCT) and transthoracic echocardiography (TTE) in predicting the type of TAVI surgical valve were compared and analyzed. The results showed that the mean absolute error (MAE) (0.01) and root mean square error (RMSE) (0.086) of the MBIR model were higher than the reconstruction model in this research. The structural similarity (SSIM) (0.831) and peak signal-to noise ratio (PSNR) (32.77 dB) of the MBIR model were lower than the reconstruction model, and the differences were considerable (
). Of the valve models selected based on the TTE measurement results, 35 cases were accurately predicted and 27 cases were incorrectly predicted. The accuracy of MSCT was 87.1%, the specificity was 98.84%, and the sensitivity was 92.87%; all of which were significantly higher than TTE (
). In summary, compared with the MBIR reconstruction model, the imaging results of the model established in this research were closer to the real image. Compared with TTE, MSCT had higher accuracy, sensitivity, and specificity and can provide more accurate preoperative predictions for patients undergoing TAVI surgery.
Collapse
|
14
|
Giorgio Malvindi P, Luthra S, Santarpino G, Ramadan T, Hunduma G, Olevano C, Ohri SK. Early- and mid-term outcomes of reinterventions for aortic bioprosthesis failure. Asian Cardiovasc Thorac Ann 2022; 30:788-796. [PMID: 35469437 DOI: 10.1177/02184923221094974] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022]
Abstract
BACKGROUND The aim of this study was to evaluate early- and mid-term results of our actual practice embedding redo aortic valve replacement and transcatheter procedures for aortic bioprosthetic failure. METHODS Data for aortic valve reinterventions (redo surgical aortic valve replacement, isolated redo aortic valve replacement, and valve-in-valve transcatheter aortic valve implantation, transcatheter valve-in-valve procedure) were collected (2010-2019). Logistic regression analysis was performed to identify predictors favouring the choice of transcatheter against redo surgery. Cox analysis was used to study the association of preoperative variables with survival. Survival probabilities were calculated with Kaplan-Meier analysis and compared using a log-rank test. RESULTS A total of 125 patients were included (redo surgical aortic valve replacement: 84 patients, valve-in-valve transcatheter aortic valve implantation: 41 patients). Median age was 74 [63-80] years, 58% of the patients were male and the median logistic EuroSCORE was 15 [8-26] %. There was no early mortality. Eighteen patients (redo surgical aortic valve replacement: 15, valve-in-valve transcatheter aortic valve implantation: 3) sustained at least one postoperative complication. At pre-discharge transthoracic echocardiogram, valve-in-valve transcatheter aortic valve implantation had significantly higher trans-prosthetic gradients (mean gradient: valve-in-valve transcatheter aortic valve implantation 18 mmHg vs. redo surgical aortic valve replacement 14 mmHg, p < 0.001). Overall survival probabilities were 94% and 73% at 1 year and 5 years, respectively. Previous coronary artery bypass surgery operation and age were independently associated with lower survival probabilities during the follow-up. CONCLUSIONS Redo surgical aortic valve replacement and valve-in-valve transcatheter aortic valve implantation are both safe and effective for aortic bioprosthetic failure. Further valve-in-valve data are needed to determine the haemodynamic performance of transcatheter prostheses and its impact on long-term outcomes.
Collapse
Affiliation(s)
- Pietro Giorgio Malvindi
- Wessex Cardiothoracic Centre, 7425University Hospital Southampton, Southampton, UK.,Department of Experimental and Clinical Medicine, Polytechnic University of Marche, Ancona, Italy
| | - Suvitesh Luthra
- Wessex Cardiothoracic Centre, 7425University Hospital Southampton, Southampton, UK
| | - Giuseppe Santarpino
- Cardiac Surgery Unit, Department of Experimental and Clinical Medicine, University "Magna Graecia" of Catanzaro, Catanzaro, Italy
| | - Taha Ramadan
- Wessex Cardiothoracic Centre, 7425University Hospital Southampton, Southampton, UK
| | - Gabriel Hunduma
- Wessex Cardiothoracic Centre, 7425University Hospital Southampton, Southampton, UK
| | - Carlo Olevano
- Wessex Cardiothoracic Centre, 7425University Hospital Southampton, Southampton, UK
| | - Sunil K Ohri
- Wessex Cardiothoracic Centre, 7425University Hospital Southampton, Southampton, UK
| |
Collapse
|
15
|
Bleiziffer S, Rudolph TK. Patient Prosthesis Mismatch After SAVR and TAVR. Front Cardiovasc Med 2022; 9:761917. [PMID: 35433878 PMCID: PMC9005892 DOI: 10.3389/fcvm.2022.761917] [Citation(s) in RCA: 14] [Impact Index Per Article: 4.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/20/2021] [Accepted: 01/13/2022] [Indexed: 11/23/2022] Open
Abstract
Patient-prosthesis mismatch (PPM) remains one out of many factors to be considered during decision-making for the treatment of aortic valve pathologies. The idea of adequate sizing of a prosthetic heart valve was established by Rahimtoola already in 1978. In this article, the author described the phenomenon that the orifice area of a prosthetic heart valve may be too small for the individual patient. PPM is assessed by measurement or projection of the prosthetic effective orifice area indexed to body surface area (iEOA), while it is recommended to use different cut point values for non-obese and obese patients for the categorization of moderate and severe PPM. Several factors influence the accuracy of both the projected and the measured iEOA for PPM assessment, which leads to a certain number of false assignments to the PPM or no PPM group. Despite divergent findings on the impact of PPM on clinical outcomes, there is consensus that PPM should be avoided to prevent sequelae of increased prosthetic gradients after aortic valve replacement. To prevent PPM, it is required to anticipate the iEOA of the prosthesis prior to the procedure. The use of adequate reference tables, derived from echocardiographically measured mean effective orifice area (EOA) values from preferably large numbers of patients, is most appropriate to predict the iEOA. Such tables should be used also for transcatheter heart valves in the future. During the decision-making process, all available options should be taken into account for the individual patient. If the predicted size and type of a surgical prosthesis cannot be implanted, additional surgical procedures, such as annular enlargement with the Manougian technique, or alternative procedures, such as transcatheter aortic valve implantation (TAVI) can prevent PPM. PPM prevention for TAVI patients is a new field of interest and includes anticipation of the iEOA, prosthesis selection, and procedural strategies.
Collapse
Affiliation(s)
- Sabine Bleiziffer
- Department of Thoracic and Cardiovascular Surgery, Heart and Diabetes Center North Rhine-Westphalia, University Hospital Ruhr-University Bochum, Bad Oeynhausen, Germany
- *Correspondence: Sabine Bleiziffer
| | - Tanja K. Rudolph
- Department for General and Interventional Cardiology/Angiology, Heart and Diabetes Center North Rhine-Westphalia Bochum, University Hospital of the Ruhr University, Bad Oeynhausen, Germany
| |
Collapse
|
16
|
Zebhi B, Lazkani M, Bark D. Calcific Aortic Stenosis-A Review on Acquired Mechanisms of the Disease and Treatments. Front Cardiovasc Med 2021; 8:734175. [PMID: 34604358 PMCID: PMC8486019 DOI: 10.3389/fcvm.2021.734175] [Citation(s) in RCA: 18] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/30/2021] [Accepted: 08/18/2021] [Indexed: 11/13/2022] Open
Abstract
Calcific aortic stenosis is a progressive disease that has become more prevalent in recent decades. Despite advances in research to uncover underlying biomechanisms, and development of new generations of prosthetic valves and replacement techniques, management of calcific aortic stenosis still comes with unresolved complications. In this review, we highlight underlying molecular mechanisms of acquired aortic stenosis calcification in relation to hemodynamics, complications related to the disease, diagnostic methods, and evolving treatment practices for calcific aortic stenosis.
Collapse
Affiliation(s)
- Banafsheh Zebhi
- Department of Mechanical Engineering, Colorado State University, Fort Collins, CO, United States
| | - Mohamad Lazkani
- Medical Center of the Rockies, University of Colorado Health, Loveland, CO, United States
| | - David Bark
- Department of Pediatrics, Washington University in Saint Louis, Saint Louis, MO, United States.,Department of Biomedical Engineering, Washington University in Saint Louis, Saint Louis, MO, United States
| |
Collapse
|
17
|
Vaidya YP, Cavanaugh SM, Sandhu AA. Surgical aortic valve replacement in small aortic annulus. J Card Surg 2021; 36:2502-2509. [PMID: 33821514 DOI: 10.1111/jocs.15555] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 03/24/2021] [Indexed: 11/29/2022]
Abstract
BACKGROUND Although aortic valve replacement (AVR) has been the standard of treatment for severe aortic stenosis, a small aortic annulus (SAA) poses significant challenges. Improvements in valve designs and evolution in surgical techniques have led to improved outcomes, however, the ideal prosthetic valve remains elusive. METHODS We performed a comprehensive literature review to discuss the surgical management of aortic stenosis, with a special focus on patients with SAA. RESULTS Stentless valves and root replacement techniques have been shown to overcome the hemodynamic challenges associated with conventional stented bioprostheses, but are technically challenging and require longer cross-clamp times. Sutureless and rapid deployment valves mitigate the long operative time while maintaining the hemodynamic advantages. The use of transcatheter AVR has emerged as another reasonable alternative and has shown promise among patients with SAA, however, long-term outcomes are awaited. CONCLUSION There is no consensus regarding the type of valve prosthesis or replacement technique among patients with SAA. Consideration of patient comorbidities and valvular anatomy is paramount in planning the optimal strategy for AVR. Further long-term clinical trials are necessary to assess outcomes and achieve progress toward the development of the ideal prosthesis.
Collapse
Affiliation(s)
- Yash P Vaidya
- Department of Surgery, SUNY Upstate Medical University, Syracuse, New York, USA
| | - Shaelyn M Cavanaugh
- Department of Surgery, SUNY Upstate Medical University, Syracuse, New York, USA
| | - Aqeel A Sandhu
- Department of Cardiothoracic Surgery, SUNY Upstate Medical University, Syracuse, New York, USA
| |
Collapse
|
18
|
Nitta K, Fukuda Y, Susawa H, Ikenaga H, Utsunomiya H, Ishibashi K, Kurisu S, Takahashi S, Nakano Y, Awai K, Sueda T, Kihara Y. Impact of Prosthesis-Patient Mismatch After Transcatheter Aortic Valve Replacement on Changes in Cardiac Sympathetic Nervous Function. Int Heart J 2020; 61:1188-1195. [PMID: 33191358 DOI: 10.1536/ihj.20-381] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/18/2022]
Abstract
The impact of prosthesis-patient mismatch (PPM) after transcatheter aortic valve replacement (TAVR) on changes in cardiac sympathetic nervous (CSN) function remains unclear. Using 123I-metaiodobenzylguanidine (MIBG) myocardial scintigraphy, we investigated the impact of PPM after TAVR on CSN activity.We enrolled 44 of 117 patients with severe aortic stenosis who underwent TAVR for analysis in the present study. We conducted 123I-MIBG scintigraphy at baseline and at about 9 months after TAVR. Differences between baseline and post-TAVR 123I-MIBG parameters were compared between cases with and without PPM.There were 17 and 27 patients with and without PPM, respectively. Those without PPM exhibited significantly decreased left ventricular mass index (122 ± 36 g/m2 versus 108 ± 30 g/m2, P < 0.001) following TAVR, whereas those with PPM did not (117 ± 21 g/m2 versus 110 ± 17 g/m2, P = 0.09). Significant improvements in delayed heart-to-mediastinum (H/M) ratio (2.8 ± 0.4 versus 3.0 ± 0.4, P = 0.004) and washout rate (WR) (33% ± 10% versus 24% ± 12%, P < 0.001) were observed after TAVR in patients without PPM but not in those with PPM. Multivariable linear regression analysis revealed PPM to be a negative predictor of improvements in delayed H/M ratio and WR.Delayed H/M ratio and WR improve significantly after TAVR in the absence of PPM, whereas these improvements are not observed in patients with PPM. Hence, the presence of PPM is a negative predictor of improvements in delayed H/M ratio and WR in patients undergoing TAVR.
Collapse
Affiliation(s)
- Kazuhiro Nitta
- Department of Cardiovascular Medicine, Hiroshima University Graduate School of Biomedical and Health Sciences
| | - Yukihiro Fukuda
- Department of Cardiovascular Medicine, Hiroshima University Graduate School of Biomedical and Health Sciences
| | - Hitoshi Susawa
- Department of Cardiovascular Medicine, Hiroshima University Graduate School of Biomedical and Health Sciences
| | - Hiroki Ikenaga
- Department of Cardiovascular Medicine, Hiroshima University Graduate School of Biomedical and Health Sciences
| | - Hiroto Utsunomiya
- Department of Cardiovascular Medicine, Hiroshima University Graduate School of Biomedical and Health Sciences
| | - Ken Ishibashi
- Department of Cardiovascular Medicine, Hiroshima University Graduate School of Biomedical and Health Sciences
| | - Satoshi Kurisu
- Department of Cardiovascular Medicine, Hiroshima University Graduate School of Biomedical and Health Sciences
| | - Shinya Takahashi
- Department of Cardiovascular Surgery, Hiroshima University Graduate School of Biomedical and Health Sciences
| | - Yukiko Nakano
- Department of Cardiovascular Medicine, Hiroshima University Graduate School of Biomedical and Health Sciences
| | - Kazuo Awai
- Department of Diagnostic Radiology, Hiroshima University Graduate School of Biomedical and Health Sciences
| | - Taijiro Sueda
- Department of Cardiovascular Surgery, Hiroshima University Graduate School of Biomedical and Health Sciences
| | - Yasuki Kihara
- Department of Cardiovascular Medicine, Hiroshima University Graduate School of Biomedical and Health Sciences
| |
Collapse
|
19
|
Sá MPBO, Cavalcanti LRP, Sarargiotto FAS, Perazzo ÁM, Rayol SDC, Diniz RGS, Sá FBCA, Menezes AM, Lima RC. Impact of Prosthesis-Patient Mismatch on 1-Year Outcomes after Transcatheter Aortic Valve Implantation: Meta-analysis of 71,106 Patients. Braz J Cardiovasc Surg 2019; 34:318-326. [PMID: 31310471 PMCID: PMC6629219 DOI: 10.21470/1678-9741-2019-0073] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/24/2019] [Accepted: 04/27/2019] [Indexed: 11/10/2022] Open
Abstract
OBJECTIVES This study sought to evaluate the impact of prosthesis-patient mismatch (PPM) on the risk of early-term mortality after transcatheter aortic valve implantation (TAVI). METHODS Databases (Medical Literature Analysis and Retrieval System Online [MEDLINE], Excerpta Medica dataBASE [EMBASE], Cochrane Controlled Trials Register [CENTRAL/CCTR], ClinicalTrials.gov, Scientific Electronic Library Online [SciELO], Latin American and Caribbean Literature on Health Sciences [LILACS], and Google Scholar) were searched for studies published until February 2019. PPM after TAVI was defined as moderate if the indexed effective orifice area (iEOA) was between 0.85 cm2/m2 and 0.65 cm2/m2 and as severe if iEOA ≤ 0.65 cm2/m2. RESULTS The search yielded 1,092 studies for inclusion. Of these, 18 articles were analyzed, and their data extracted. The total number of patients included who underwent TAVI was 71,106. The incidence of PPM after TAVI was 36.3% (25,846 with PPM and 45,260 without PPM). One-year mortality was not increased in patients with any PPM (odds ratio [OR] 1.021, 95% confidence interval [CI] 0.979-1.065, P=0.338) neither in those with moderate PPM (OR 0.980, 95% CI 0.933-1.029, P=0.423). Severe PPM was separately associated with high risk (OR 1.109, 95% CI 1.041-1.181, P=0.001). CONCLUSION The presence of severe PPM after TAVI increased early-term mortality. Although moderate PPM seemed harmless, the findings of this study cannot not rule out the possibility of it being detrimental, since there are other registries that did not address this issue yet.
Collapse
Affiliation(s)
- Michel Pompeu Barros Oliveira Sá
- Division of Cardiovascular Surgery of Pronto-Socorro
Cardiológico Universitário de Pernambuco (PROCAPE), Recife, PE,
Brazil
- Nucleus of Postgraduate Studies and Research in Health Sciences at
Faculdade de Ciências Médicas and Instituto de Ciências
Biológicas (FCM/ICB), Recife, PE, Brazil
| | - Luiz Rafael Pereira Cavalcanti
- Division of Cardiovascular Surgery of Pronto-Socorro
Cardiológico Universitário de Pernambuco (PROCAPE), Recife, PE,
Brazil
- Universidade de Pernambuco (UPE), Recife, PE, Brazil
| | - Felipe Augusto Santos Sarargiotto
- Division of Cardiovascular Surgery of Pronto-Socorro
Cardiológico Universitário de Pernambuco (PROCAPE), Recife, PE,
Brazil
- Universidade de Pernambuco (UPE), Recife, PE, Brazil
| | - Álvaro Monteiro Perazzo
- Division of Cardiovascular Surgery of Pronto-Socorro
Cardiológico Universitário de Pernambuco (PROCAPE), Recife, PE,
Brazil
- Universidade de Pernambuco (UPE), Recife, PE, Brazil
| | - Sérgio da Costa Rayol
- Division of Cardiovascular Surgery of Pronto-Socorro
Cardiológico Universitário de Pernambuco (PROCAPE), Recife, PE,
Brazil
- Universidade de Pernambuco (UPE), Recife, PE, Brazil
| | - Roberto Gouveia Silva Diniz
- Division of Cardiovascular Surgery of Pronto-Socorro
Cardiológico Universitário de Pernambuco (PROCAPE), Recife, PE,
Brazil
- Universidade de Pernambuco (UPE), Recife, PE, Brazil
| | - Frederico Browne Correia Araújo Sá
- Division of Cardiovascular Surgery of Pronto-Socorro
Cardiológico Universitário de Pernambuco (PROCAPE), Recife, PE,
Brazil
- Universidade de Pernambuco (UPE), Recife, PE, Brazil
| | - Alexandre Motta Menezes
- Division of Cardiovascular Surgery of Pronto-Socorro
Cardiológico Universitário de Pernambuco (PROCAPE), Recife, PE,
Brazil
- Universidade de Pernambuco (UPE), Recife, PE, Brazil
| | - Ricardo Carvalho Lima
- Division of Cardiovascular Surgery of Pronto-Socorro
Cardiológico Universitário de Pernambuco (PROCAPE), Recife, PE,
Brazil
- Nucleus of Postgraduate Studies and Research in Health Sciences at
Faculdade de Ciências Médicas and Instituto de Ciências
Biológicas (FCM/ICB), Recife, PE, Brazil
| |
Collapse
|