1
|
Marmolejo A, Cázarez S, Mata CJ, Ayala S, Farell J, Ramírez NA, Navarro Castañeda CA, García L. Use of an abdominal binder in colonoscopies performed by trainees in gastrointestinal endoscopy: a randomized, double-blind, sham-controlled trial. Surg Endosc 2025; 39:3236-3246. [PMID: 40229596 DOI: 10.1007/s00464-025-11710-8] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/01/2024] [Accepted: 03/31/2025] [Indexed: 04/16/2025]
Abstract
BACKGROUND Colonoscopy is a widely used diagnostic and therapeutic tool for colonic diseases and serves as the preferred screening method for colorectal cancer (CRC). A common difficulty during colonoscopy is the looping of the colon, which can result in patient discomfort, prolonged cecal intubation time (CIT), and the need for auxiliary maneuvers. This study aimed to evaluate the efficacy and safety of using an abdominal binder during colonoscopy performed by trainees. METHODS This randomized, double-blind, sham-controlled trial was conducted at a tertiary center. Participants were outpatients aged 20-80 years undergoing elective colonoscopy. They were randomly assigned to either the abdominal binder (AB) group or the sham binder (SB) group. The primary outcome measured was cecal intubation time. Secondary outcomes included the need for manual abdominal compression and postural adjustments during the procedure. RESULTS A total of 211 participants were enrolled in the study. The median CIT was significantly shorter in the AB group compared to the SB group (728 s vs. 774 s, p = 0.008). Additionally, the AB group demonstrated a significantly reduced need for manual abdominal compression (p ≤ 0.001) and postural adjustments (p = 0.01). The requirement for abdominal compression decreased by 40% (95% CI 27.7-52.9%), while the need for postural changes was reduced by 9.4% (95% CI 1.9-88.7%). CONCLUSION The use of an abdominal binder during colonoscopy performed by trainees significantly reduced cecal intubation time and minimized the need for ancillary maneuvers, such as manual abdominal compression and postural adjustments.
Collapse
Affiliation(s)
- Antonio Marmolejo
- Department of Gastrointestinal Endoscopy, Hospital Central Norte, PEMEX, 3rd Floor, Campo Matillas 52, San Antonio, Azcapotzalco, 02720, Mexico City, Mexico
| | - Sinue Cázarez
- Department of Coloproctology, Hospital Central Norte, PEMEX, 3rd Floor, Campo Matillas 52, San Antonio, Azcapotzalco, 02720, Mexico City, Mexico
| | - Carlos J Mata
- Department of Gastrointestinal Endoscopy, Director of Endoscopy and Surgical Residency Program, Hospital Central Norte, PEMEX, 3rd Floor, Campo Matillas 52, San Antonio, Azcapotzalco, 02720, Mexico City, Mexico
| | - Sergio Ayala
- Department of Clinical Pathology, Hospital Universitario "Dr. José E. González", Av. Francisco I. Madero Pte. Mitras Centro, 1st Floor, 64460, Monterrey, Nuevo Leon, Mexico
| | - Jorge Farell
- Gastrointestinal Endoscopy, Bariatric and General Surgery, Hospital Español, Ejército Nacional Mexicano 613, Granada, Miguel Hidalgo, 11520, Mexico City, Mexico
| | - Nubia A Ramírez
- Department of Surgery, Chief and Director of Surgical Residency Program, Hospital Central Sur de Alta Especialidad, PEMEX, 7th Floor, Periférico Sur 4091 Fuentes del Pedregal, Tlalpan, 14140, Mexico City, Mexico
| | - Carlos A Navarro Castañeda
- Department of Gastrointestinal Endoscopy, Hospital General "Dr. Manuel Gea González", 3rd Floor, Calzada de Tlalpan 4800, Sección XVI, 14080, Mexico City, Mexico.
| | - Luis García
- Gastrointestinal Endoscopy and General Surgery, Hospital Angeles Acoxpa, Acoxpa 430, Coapa, Ex-Hacienda Coapa, Tlalpan, 14308, Mexico City, Mexico
| |
Collapse
|
2
|
Adali M. THE USE OF ABDOMINAL CORSETS ON COLONOSCOPY: A PROSPECTIVE RANDOMISED CONTROLLED TRIAL. ARQUIVOS BRASILEIROS DE CIRURGIA DIGESTIVA : ABCD = BRAZILIAN ARCHIVES OF DIGESTIVE SURGERY 2025; 38:e1873. [PMID: 40105628 PMCID: PMC11908742 DOI: 10.1590/0102-6720202500004e1873] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 09/19/2024] [Accepted: 12/16/2024] [Indexed: 03/20/2025]
Abstract
BACKGROUND Colonoscopy is a widely used endoscopic procedure to investigate diseases of the colon and rectum. Colonoscopy procedure has difficulties for the patient and endoscopist. AIMS To investigate whether the use of an abdominal corset can make the colonoscopy procedure easier and faster. METHODS This is a prospective randomised controlled study. Patients over 18 years of age who underwent elective colonoscopy in our clinic were evaluated. Patients were divided into two groups according to the use of the corset. Variables were compared between the groups. RESULTS A total of 204 patients were included in the study. Corsets were used in 97 patients and not used in 107 patients. The need for manual compression was found to be decreased in the corset use group. There was no effect of corset use on cecal intubation time in the general population. It was found that cecal intubation time decreased with corset use in patients with body mass index - BMI<30 and male gender. CONCLUSIONS The need for manual compression can be reduced by the use of an abdominal corset during colonoscopy. The use of an abdominal corset may make the colonoscopy procedure faster and easier for the endoscopist and the patient.
Collapse
Affiliation(s)
- Mert Adali
- Health Sciences University, Bursa Yuksek Ihtisas Training and Research Hospital, General Surgery Unit - Yildirim, Bursa, Turkey
| |
Collapse
|
3
|
Zhang FB, Zhang JP, Bai YQ, Zhang DJ, Cao XG, Guo CQ. Effect of Abdominal Compression on Total Single-Balloon Enteroscopy Rate: A Randomized Controlled Trial. Mayo Clin Proc 2023; 98:1660-1669. [PMID: 37923523 DOI: 10.1016/j.mayocp.2023.02.031] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/18/2022] [Revised: 02/02/2023] [Accepted: 02/24/2023] [Indexed: 11/07/2023]
Abstract
OBJECTIVE To evaluate whether abdominal compression significantly increased the total enteroscopy rate in single-balloon enteroscopy (SBE). METHODS Consecutive patients who underwent SBE at 2 hospitals were prospectively included between June 1, 2020, and September 30, 2021. They were randomly divided into an abdominal compression group and a non-abdominal compression group with use of sealed envelopes generated by a computer. Total enteroscopy rates were compared between the groups. RESULTS The study included 200 patients. The total enteroscopy rates were 73% and 16% in the abdominal compression and non-abdominal compression groups, respectively (relative risk, 13.55; 95% CI, 6.79 to 27.00; P<.001). The total enteroscopy rate was higher in the 70 patients who were identified to have undergone no previous abdominal surgery or small intestinal stenosis than in the 32 patients who had undergone such procedures in the abdominal compression group (84% vs 47%; relative risk, 6.08; 95% CI, 2.36 to 15.67; P<.001). Relevant positive findings were not significantly different between the groups (58% vs 45%; P=.07). Binary logistic regression analysis found abdominal compression to be associated with a better total enteroscopy rate (odds ratio, 16.68; 95% CI, 7.92 to 35.15; P<.001), and the presence of previous abdominal surgery or small intestinal stenosis was associated with difficulty in completing the total enteroscopy procedure (odds ratio, 0.26; 95% CI, 0.12 to 0.58; P<.01). CONCLUSION Abdominal compression significantly increased the total enteroscopy rate in SBE. Complete total enteroscopy may be challenging in patients with a history of abdominal surgery or small intestinal stenosis.
Collapse
Affiliation(s)
- Fang-Bin Zhang
- Department of Gastroenterology, First Affiliated Hospital of Zhengzhou University, Zhengzhou, China.
| | - Jin-Ping Zhang
- Department of Gastroenterology, First Affiliated Hospital of Zhengzhou University, Zhengzhou, China
| | - Yang-Qiu Bai
- Department of Gastroenterology, Henan Provincial People's Hospital, People's Hospital of Henan University, People's Hospital of Zhengzhou University, Zhengzhou, Henan Province, China
| | - Du-Juan Zhang
- Department of Gastroenterology, First Affiliated Hospital of Zhengzhou University, Zhengzhou, China
| | - Xin-Guang Cao
- Department of Gastroenterology, First Affiliated Hospital of Zhengzhou University, Zhengzhou, China
| | - Chang-Qing Guo
- Department of Gastroenterology, First Affiliated Hospital of Zhengzhou University, Zhengzhou, China
| |
Collapse
|
4
|
Abuelazm MT, Abdelnabi M, Mahmoud A, Albarakat MM, Mohamed I, Saeed A, Gowaily I, Abdelazeem B. The impact of abdominal compression devices on colonoscopy outcomes: a systematic review and meta-analysis of randomized controlled trials. Curr Med Res Opin 2023; 39:1247-1256. [PMID: 37526014 DOI: 10.1080/03007995.2023.2243214] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/05/2023] [Revised: 07/19/2023] [Accepted: 07/28/2023] [Indexed: 08/02/2023]
Abstract
OBJECTIVE Colonoscopy is the gold standard method for colorectal cancer screening. Looping occurs in 91% of cases undergoing colonoscopy and can cause patient discomfort, prolonged cecal intubation time (CIT), and colon perforation. This meta-analysis investigates the impact of abdominal compression devices (ACD) on colonoscopy outcomes. METHODS A systematic review and meta-analysis synthesizing randomized controlled trials (RCTs), retrieved by systematically searching: PubMed, EMBASE, WOS, SCOPUS, and Cochrane through February 2nd, 2023. Continuous and dichotomous outcomes were pooled using mean difference (MD) and risk ratio (RR) along with confidence interval (CI) using Revman. Our review protocol was prospectively published on PROSPERO with ID: CRD42023397344. RESULTS We included eight RCTs with a total of 1,889 patients. ACD was effective to decrease CIT (MD: -2.15 with a 95% CI [-3.49, -0.80], p = .002), postural change (RR: 0.57 with 95% CI [0.49, 0.66], p = .00001), and VAS pain score (MD: -1.49 with 95% CI [-1.81, -1.17], p = .0001). However, there was no difference between ACD and control groups regarding manual compression (RR: 0.65 with 95% CI [0.42, 1.00], p = .05), complete colonoscopy rate (CCR) (RR: 1.01 with 95% CI [0.99, 1.04], p = .31), and cecal intubation length (CIL) (MD: -2.25 with 95% CI [-7.64, 3.14], p = .41). CONCLUSION ACD during colonoscopy may enhance patient comfort by reducing CIT, pain, and postural changes. Nevertheless, additional RCTs are necessary to validate these results and determine the most suitable approach to utilize ACD for colonoscopy.
Collapse
Affiliation(s)
| | - Mohamed Abdelnabi
- Department of Clinical Pharmacy, University of Michigan, Ann Arbor, MI, USA
| | | | | | - Islam Mohamed
- Department of Internal Medicine, University of Missouri, Kansas, MO, USA
| | | | | | - Basel Abdelazeem
- Department of Internal Medicine, McLaren Health Care, Flint, MI, USA
- Department of Internal Medicine, Michigan State University, East Lansing, MI, USA
| |
Collapse
|
5
|
Yu GQ, Huang XM, Li HY, Tang W, Hu DM, Lü MH, Fu KI. Use of an abdominal obstetric binder in colonoscopy: A randomized, prospective trial. J Gastroenterol Hepatol 2018; 33:1365-1369. [PMID: 29292858 DOI: 10.1111/jgh.14077] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/15/2017] [Revised: 11/25/2017] [Accepted: 12/19/2017] [Indexed: 12/09/2022]
Abstract
BACKGROUND AND AIMS Various methods have been reported as aids to cecal intubation. This study aimed to prospectively investigate whether an abdominal obstetric binder (AOB) used during pregnancy and attached to the patients' abdomen during colonoscopy could facilitate effective colonoscopic insertion. METHODS This was a prospective study of 451 consecutive outpatient colonoscopies performed by a single experienced endoscopist. The recruited patients were randomly separated into two groups that received colonoscopy either with (Group A) or without an AOB attached (Group B). The cecal intubation time, cecal intubation length of the colonoscope, use of manual pressure, position change of each patient, and the number of patients with abdominal distension were collected for comparison. RESULTS A total of 451 patients (224 in Group A and 227 in Group B) were ultimately included in this study. In Group A, cecal intubation time and cecal intubation length of colonoscope (CIL) were significantly reduced (P < 0.001). The patients had significantly fewer position changes and manual pressure in Group A (P < 0.001). Significantly less abdominal distension was reported by patients in Group A (P < 0.001). CONCLUSIONS During colonoscopy, the application of an AOB provided a significantly faster and more effective colonoscope insertion.
Collapse
Affiliation(s)
- Guang Qiu Yu
- Department of Gastroenterology, The Second Affiliated Hospital of Suzhou University, Jiangsu Province, Suzhou, China
| | - Xiao Mei Huang
- Department of Gastroenterology, The Affiliated Hospital of Southwest Medical University, Sichuan Province, Luzhou, China
| | - Hai Yan Li
- Department of Gastroenterology, The Second Affiliated Hospital of Suzhou University, Jiangsu Province, Suzhou, China
| | - Wen Tang
- Department of Gastroenterology, The Second Affiliated Hospital of Suzhou University, Jiangsu Province, Suzhou, China
| | - Duan Min Hu
- Department of Gastroenterology, The Second Affiliated Hospital of Suzhou University, Jiangsu Province, Suzhou, China
| | - Mu Han Lü
- Department of Gastroenterology, The Affiliated Hospital of Southwest Medical University, Sichuan Province, Luzhou, China
| | - Kuang-I Fu
- Department of Endoscopy, Kanma Memorial Hospital, Nasushiobara, Japan
| |
Collapse
|
6
|
Crockett SD, Cirri HO, Kelapure R, Galanko JA, Martin CF, Dellon ES. Use of an Abdominal Compression Device in Colonoscopy: A Randomized, Sham-Controlled Trial. Clin Gastroenterol Hepatol 2016; 14:850-857.e3. [PMID: 26767313 PMCID: PMC4875866 DOI: 10.1016/j.cgh.2015.12.039] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/28/2015] [Revised: 12/21/2015] [Accepted: 12/21/2015] [Indexed: 02/07/2023]
Abstract
BACKGROUND & AIMS Looping is a common problem during colonoscopy that prolongs procedure time. We aimed to determine the efficacy and safety of ColoWrap, an external abdominal compression device, with respect to insertion time and other procedural outcomes. METHODS We performed a prospective study of outpatients undergoing elective colonoscopy (40-80 years old; mean age, 60.5 years) at endoscopy facilities in the University of North Carolina Hospitals from April 2013 through March 2014. Subjects were randomly assigned to groups that received either ColoWrap (n = 175) or a sham device (control, n = 175) during colonoscopy. Colonoscopists and staff were blinded to the application. The primary outcome was cecal intubation time (CIT). Secondary outcomes included use of manual pressure and position change. RESULTS The mean CIT was similar for the control and ColoWrap groups (6.69 vs 6.67 minutes; P = .98). There were no statistical differences in the frequency of manual pressure (45% for controls vs 37% for ColoWrap group, P = .13) or position changes (4% for controls vs 2% for ColoWrap group, P = .36). Among patients with body mass index between 30 and 40 kg/m(2) (n = 78), CIT was significantly lower for patients in the ColoWrap group (4.69 minutes) than controls (6.10 minutes) (P = .03). Adverse events were similar between groups. CONCLUSIONS In patients undergoing elective colonoscopy, application of an external abdominal compression device did not improve CIT or affect the frequency of ancillary maneuvers. A possible benefit was observed in patients with body mass index between 30 and 40 kg/m(2), but further studies are needed. ClinicalTrials.gov number: NCT02025504.
Collapse
|
7
|
Szura M, Bucki K, Matyja A, Kulig J. Evaluation of magnetic scope navigation in screening endoscopic examination of colorectal cancer. Surg Endosc 2011; 26:632-8. [PMID: 21959687 PMCID: PMC3271220 DOI: 10.1007/s00464-011-1930-8] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/02/2011] [Accepted: 08/31/2011] [Indexed: 02/08/2023]
Abstract
Background Colorectal cancer is the most common cancer in Europe. Early diagnosis and treatment gives the patient a chance for complete recovery. Screening colonoscopies in the symptom-free patients are currently performed on a wide scale. The examinations are performed under local anesthesia which does not eliminate all discomfort and pain related to the examination. The aim of this study was to evaluate magnetic scope navigation in screening endoscopic examinations performed to detect early-stage colorectal cancer. Methods The study group consisted of 200 patients, aged 40–65 years, who were free from colon cancer symptoms. All patients underwent complete colonoscopy under local anesthesia. The equipment could be fitted with the scope that allows three-dimensional observation of instrument localization in the bowel. The examination was performed by three experienced endoscopists, each of whom performed over 5,000 colonoscopies. The patients were randomized to two groups: those whose equipment did not have 3D navigation (group I) and those whose equipment did have 3D navigation (group II). Each group consisted of 100 cases matched by gender, age, and BMI. The authors compared the duration of introducing instrument to cecum, the pulse rate before the examination and at the time the instrument reached the cecum, and subjective pain evaluation by the patient on the visual analog scale. Results Group I consisted of 54 women and 46 men with a mean age of 54.6 years and mean BMI of 27.8 kg/m2, and group II had 58 women and 42 men, mean age of 55.1 years and mean BMI of 26.4 kg/m2. The average time it took for the instrument to reach the cecum was 216s in group I and 181s in group II (P < 0.05). Pain measured on the 10-point VAS scale was 2.44 in group I and 1.85 in group II (P < 0.05). The results showed a significantly shorter time for the instrument to reach the cecum in group II and significantly lower pain intensity during the examination was reported by the group II patients. No significant differences were found in the pulse measurements between the groups (P = 0.5). Conclusions 3D navigation during colonoscopy decreases the time for the instrument to reach the cecum and lowers pain intensity subjectively reported by the patients. The use of 3D and the possibility to observe instrument localization and maneuvers brings more comfort to the patients.
Collapse
Affiliation(s)
- Miroslaw Szura
- 1st Department of General and GI Surgery, Medical College Jagiellonian University, Kopernika 40, 31-501, Krakow, Poland.
| | | | | | | |
Collapse
|