1
|
Guo B, Gan H, Xue M, Huang Z, Lin Z, Li S, Zheng P, Sun B. The Changing and Predicted Trends in Chronic Obstructive Pulmonary Disease Burden in China, the United States, and India from 1990 to 2030. Int J Chron Obstruct Pulmon Dis 2024; 19:695-706. [PMID: 38476123 PMCID: PMC10929568 DOI: 10.2147/copd.s448770] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/10/2023] [Accepted: 03/01/2024] [Indexed: 03/14/2024] Open
Abstract
Background This study analyzed the burden of chronic obstructive pulmonary disease (COPD) in China, the United States, and India from 1990 to 2019 and projected the trends for the next decade. Methods This study utilized the GBD 2019 to compare the age-standardized incidence rate (ASIR), age-standardized mortality rate (ASMR), age-standardized disability-adjusted life years (DALYs) rate, and the proportion attributed to different risk factors in China, the United States, and India. Joinpoint models and autoregressive integrated moving average (ARIMA) models were employed to capture the changing trends in disease burden and forecast outcomes. Results From 1990 to 2019, China's age-standardized COPD incidence and mortality rates decreased by 29% and 70%, respectively. In the same period, India's rates decreased by 8% and 33%, while the United States saw an increase of 9% in COPD incidence and a 22% rise in mortality rates. Smoking and ambient particulate matter pollution are the two most significant risk factors for COPD, while household air pollution from solid fuels and low temperatures are the least impactful factors in the United States and India, respectively. The proportion of risk from household air pollution from solid fuels is higher in India than in China and the United States. Predictions for 2030 suggest that the age-standardized DALY rates, ASIR, and ASMR in the United States and India are expected to remain stable or decrease, while China's age-standardized incidence rate is projected to rise. Conclusion Over the past three decades, the incidence of COPD has been decreasing in China and India, while showing a slight increase in the United States. Smoking and ambient particulate matter pollution are the primary risk factors for men and women, respectively. The risk of household air pollution from solid fuels in India needs attention.
Collapse
Affiliation(s)
- Baojun Guo
- Department of Clinical Laboratory of the First Affiliated Hospital of Guangzhou Medical University, State Key Laboratory of Respiratory Disease, National Center for Respiratory Medicine, National Clinical Research Center for Respiratory Disease, Guangzhou Institute of Respiratory Health, Guangzhou, 510120, People’s Republic of China
- School of Medicine, Henan University, Kaifeng, 475004, People’s Republic of China
| | - Hui Gan
- Department of Clinical Laboratory of the First Affiliated Hospital of Guangzhou Medical University, State Key Laboratory of Respiratory Disease, National Center for Respiratory Medicine, National Clinical Research Center for Respiratory Disease, Guangzhou Institute of Respiratory Health, Guangzhou, 510120, People’s Republic of China
| | - Mingshan Xue
- Department of Clinical Laboratory of the First Affiliated Hospital of Guangzhou Medical University, State Key Laboratory of Respiratory Disease, National Center for Respiratory Medicine, National Clinical Research Center for Respiratory Disease, Guangzhou Institute of Respiratory Health, Guangzhou, 510120, People’s Republic of China
- Guangzhou Eighth People’s Hospital, Guangzhou Medical University, Guangzhou, 510060, People’s Republic of China
| | - Zhifeng Huang
- Department of Clinical Laboratory of the First Affiliated Hospital of Guangzhou Medical University, State Key Laboratory of Respiratory Disease, National Center for Respiratory Medicine, National Clinical Research Center for Respiratory Disease, Guangzhou Institute of Respiratory Health, Guangzhou, 510120, People’s Republic of China
| | - Zhiwei Lin
- Department of Clinical Laboratory of the First Affiliated Hospital of Guangzhou Medical University, State Key Laboratory of Respiratory Disease, National Center for Respiratory Medicine, National Clinical Research Center for Respiratory Disease, Guangzhou Institute of Respiratory Health, Guangzhou, 510120, People’s Republic of China
| | - Shiyun Li
- Department of Clinical Laboratory of the First Affiliated Hospital of Guangzhou Medical University, State Key Laboratory of Respiratory Disease, National Center for Respiratory Medicine, National Clinical Research Center for Respiratory Disease, Guangzhou Institute of Respiratory Health, Guangzhou, 510120, People’s Republic of China
| | - Peiyan Zheng
- Department of Clinical Laboratory of the First Affiliated Hospital of Guangzhou Medical University, State Key Laboratory of Respiratory Disease, National Center for Respiratory Medicine, National Clinical Research Center for Respiratory Disease, Guangzhou Institute of Respiratory Health, Guangzhou, 510120, People’s Republic of China
| | - Baoqing Sun
- Department of Clinical Laboratory of the First Affiliated Hospital of Guangzhou Medical University, State Key Laboratory of Respiratory Disease, National Center for Respiratory Medicine, National Clinical Research Center for Respiratory Disease, Guangzhou Institute of Respiratory Health, Guangzhou, 510120, People’s Republic of China
| |
Collapse
|
2
|
Ebrahimifakhar A, Poursadegh M, Hu Y, Yuill DP, Luo Y. A systematic review and meta-analysis of field studies of portable air cleaners: Performance, user behavior, and by-product emissions. THE SCIENCE OF THE TOTAL ENVIRONMENT 2024; 912:168786. [PMID: 38008326 DOI: 10.1016/j.scitotenv.2023.168786] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/25/2023] [Revised: 11/08/2023] [Accepted: 11/20/2023] [Indexed: 11/28/2023]
Abstract
Indoor air quality is important for the health of building occupants, and public interest in controlling indoor airborne pathogens increased dramatically with the COVID-19 pandemic. Pollutant concentrations can be controlled locally using portable air cleaners (sometimes called air purifiers), which allow occupants to apply air cleaning technology to meet their needs in the location and times that they find appropriate. This paper provides a systematic review of scientific literature that describes field studies of the effectiveness of portable air cleaners. Over 500 papers were considered, and 148 were reviewed in detail, to extract 35 specific research results (e.g., particulate removal performance) or characteristics (e.g., type of building). These were aggregated to provide an overview of results and approaches to this type of research, and to provide meta-analyses of the results. The review includes: descriptions of the geographical location of the research; rate of publications over time; types of buildings and occupants in the field study; types of air cleaner technology being tested; pollutants being measured; resulting pollutant removal effectiveness; patterns of usage and potential barriers to usage by occupants; and the potential for by-product emissions in some air cleaner technologies. An example result is that 83 of the 148 papers measured reductions in fine particulates (PM2.5) and found a mean reduction of 49 % with standard deviation of 20 %. The aggregated results were approximately normally distributed, ranging from finding no significant reduction up to a maximum above 90 % reduction. Sixteen of the 148 papers considered gaseous pollutants, such as volatile organic compounds, nitrogen dioxide, and ozone; 36 papers considered biological pollutants, such as bacteria, viruses, pollen, fungi, etc. An important challenge, common to several studies, is that occupants run the air cleaners for shorter periods and on low airflow rate settings, because of concerns about noise, drafts, and electricity cost, which significantly reduces air cleaning effectiveness.
Collapse
Affiliation(s)
- Amir Ebrahimifakhar
- Delos Labs, Delos, New York, NY 10014, USA; Durham School of Architectural Engineering and Construction, University of Nebraska - Lincoln, 1110 S. 67th Street, Omaha, NE 68182, USA.
| | - Mehrdad Poursadegh
- Durham School of Architectural Engineering and Construction, University of Nebraska - Lincoln, 1110 S. 67th Street, Omaha, NE 68182, USA.
| | - Yifeng Hu
- Durham School of Architectural Engineering and Construction, University of Nebraska - Lincoln, 1110 S. 67th Street, Omaha, NE 68182, USA; Buildings and Transportation Science Division, Oak Ridge National Laboratory, Oak Ridge, TN 37830, USA.
| | - David P Yuill
- Durham School of Architectural Engineering and Construction, University of Nebraska - Lincoln, 1110 S. 67th Street, Omaha, NE 68182, USA.
| | - Yu Luo
- Department of Applied Physics and Applied Mathematics, Columbia University, 500 W. 120th Street, New York, NY 10027, USA.
| |
Collapse
|
3
|
Vilčeková S, Burdová EK, Kiseľák J, Sedláková A, Mečiarová ĽV, Moňoková A, Doroudiani S. Assessment of indoor environmental quality and seasonal well-being of students in a combined historic technical school building in Slovakia. ENVIRONMENTAL MONITORING AND ASSESSMENT 2023; 195:1524. [PMID: 37994965 DOI: 10.1007/s10661-023-12147-z] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/28/2023] [Accepted: 11/14/2023] [Indexed: 11/24/2023]
Abstract
One of the major present challenges in the building sector is to construct sustainable and low-energy buildings with a healthy, safe, and comfortable environment. This study is designed to explore long-term impacts of indoor environmental quality (IEQ) parameters in a historic technical school building on the health and comfort of students. The main objective is to identify environmental problems in schools and to direct public policy towards the enhancement of in-service historic buildings. The collected data on five consecutive days in various seasons from five different classrooms indicate allergy in 45% and asthma in 10% of students. Environmental factors, such as temperature, draught, noise, or light, affected 51% of students' attention. Low temperature, unpleasant air, noise, and draught were found to be the most frequent concerns for students. The lowest temperature was measured during spring at 17.6 °C, the lowest humidity of 21.1% in winter, the largest CO2 amount in the air in autumn at 2041 ppm level, and the greatest total volatile organic compounds (TVOC) as 514 µg/m3. The experimental and statistical analysis results suggest the necessity of a comprehensive restoration of the building with a focus on enhancement of IEQ as well as replacement of old non-standard materials. An effective ventilation system is also necessary. The building requires major renovations to preserve its historic features while safeguarding the well-being and comfort of students and staff. Further research is needed on acoustics, lighting, and energy factors as well as the health effects of old building materials.
Collapse
Affiliation(s)
- Silvia Vilčeková
- Faculty of Civil Engineering, Institute of Sustainable and Circular Construction, Technical University of Košice, Vysokoškolská 4, 042 00, Košice, Slovak Republic
| | - Eva Krídlová Burdová
- Faculty of Civil Engineering, Institute of Sustainable and Circular Construction, Technical University of Košice, Vysokoškolská 4, 042 00, Košice, Slovak Republic
| | - Jozef Kiseľák
- Faculty of Science, Institute of Mathematics, Pavol Jozef Šafárik University, Jesenná 5, 04001, Košice, Slovak Republic
| | - Anna Sedláková
- Faculty of Civil Engineering, Institute of Architectural Engineering, Technical University of Košice, Vysokoškolská 4, 042 00, Košice, Slovak Republic
| | | | | | | |
Collapse
|
4
|
Zhang Y, Liu Y, Li S, Xu R, Yu P, Ramos C, Ebrahimifakhar A, Guo Y. Efficiency of portable air purification on public buses: A pilot study. ENVIRONMENTAL POLLUTION (BARKING, ESSEX : 1987) 2023; 329:121696. [PMID: 37088254 DOI: 10.1016/j.envpol.2023.121696] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/21/2023] [Revised: 04/15/2023] [Accepted: 04/20/2023] [Indexed: 05/03/2023]
Abstract
High concentrations of fine particulate matter (PM2.5) have been frequently reported in public transit systems and can cause adverse health effect. The portable air purifier is an inexpensive solution that could potentially clean in-cabin PM2.5. This study aims to find the PM2.5 removal efficiency of portable air purifiers in a public transit bus. In various scenarios, after artificially preloading the in-cabin PM2.5 concentration to 400 μg/m3, the concentrations were measured every 10 s, with and without the intervention of air purifiers. In a test bus with a volume of approximately 62.5 m3, three portable air purifiers were capable of reducing the average concentration of PM2.5 by 42-74%, from 400 μg/m3, to levels below 15 μg/m3, the acceptable short-term exposure concentration recommended by WHO. When high concentrations of outdoor PM2.5 entered the bus, purifiers maintained a relatively low level of in-cabin PM2.5. Air purifiers were more effective in reducing in-cabin PM2.5 than traditional air filtration and ventilation methods (air conditioning system filtration and door opening) in public transit buses. The deployed air purifiers reduced the concentration of particulate matter inside the bus, which may reduce the health risk of PM2.5 exposure and the spreading of airborne infections in public transit, thus, implying the potential to enhance passengers' and drivers' health.
Collapse
Affiliation(s)
- Yuxi Zhang
- School of Public Health and Preventive Medicine, Monash University, Melbourne, 3004, Australia
| | - Yanming Liu
- School of Public Health and Preventive Medicine, Monash University, Melbourne, 3004, Australia
| | - Shanshan Li
- School of Public Health and Preventive Medicine, Monash University, Melbourne, 3004, Australia
| | - Rongbin Xu
- School of Public Health and Preventive Medicine, Monash University, Melbourne, 3004, Australia
| | - Pei Yu
- School of Public Health and Preventive Medicine, Monash University, Melbourne, 3004, Australia
| | | | | | - Yuming Guo
- School of Public Health and Preventive Medicine, Monash University, Melbourne, 3004, Australia.
| |
Collapse
|
5
|
Kumar P, Rawat N, Tiwari A. Micro-characteristics of a naturally ventilated classroom air quality under varying air purifier placements. ENVIRONMENTAL RESEARCH 2023; 217:114849. [PMID: 36414109 DOI: 10.1016/j.envres.2022.114849] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/25/2022] [Revised: 11/14/2022] [Accepted: 11/16/2022] [Indexed: 06/16/2023]
Abstract
A naturally-ventilated operational classroom was instrumented at 18 locations to assess spatial variations of classroom air pollution (CRAP), thermal comfort and ventilation indicators under 10 different scenarios (base scenario without air purifier (AP); three single AP scenarios; three scenarios with two APs at same locations; three scenarios with two APs at different locations). Unlike PM2.5, monitored PM10 and CO2 concentrations followed the diurnal occupancy profile. Highest vertical variation (38%) in CO2 was at the classroom entry zone at 40-300 cm height. CO2 increased until 225 cm before stratifying further. PM10 increased to highest levels at children sitting height (100 cm) before decreasing to adult breathing height (150 cm). Highest horizontal variations in CO2 (PM10) were 29% (22%) at 40 cm height between the entry and occupied zones. Teachers' exposure to CO2 (PM10) in breathing zone varied by up to 6% (3%); the corresponding variations across monitored locations were up to 14% (19%). Teachers' exposure to CO2 was up to 13% higher than that of children and 18% lower for PM10. Traffic emissions (PM2.5 and NOx), secondary pollutants (VOCs and O3), thermal comfort parameters and noise level in the classroom varied insignificantly among scenarios. PM10 reduction was not doubled by using two air purifiers, which were most effective when placed within the highest PM concentration zone. Cross-comparisons of scenarios showed: use of AP reduced classroom's spatial average PM10 up to 14%; PM10 was reduced by increasing the AP's filtration capacity; and AP had insignificant impact on spatial average CO2. PM10 showed a maximum reduction of 46% (teacher zone), 62% (occupied zone) and 50% (entry zone) at children's breathing height, depending on usage scenario. This study produced high-resolution data for validating the detailed numerical models for classrooms and informing decision-making on AP's placement to minimise children's exposure to CRAP and re-breathed CO2.
Collapse
Affiliation(s)
- Prashant Kumar
- Global Centre for Clean Air Research (GCARE), School of Sustainability, Civil and Environmental Engineering, Faculty of Engineering and Physical Sciences, University of Surrey, Guildford, GU2 7XH, Surrey, United Kingdom; Institute for Sustainability, University of Surrey, Guildford GU2 7XH, Surrey, United Kingdom.
| | - Nidhi Rawat
- Global Centre for Clean Air Research (GCARE), School of Sustainability, Civil and Environmental Engineering, Faculty of Engineering and Physical Sciences, University of Surrey, Guildford, GU2 7XH, Surrey, United Kingdom
| | - Arvind Tiwari
- Global Centre for Clean Air Research (GCARE), School of Sustainability, Civil and Environmental Engineering, Faculty of Engineering and Physical Sciences, University of Surrey, Guildford, GU2 7XH, Surrey, United Kingdom
| |
Collapse
|