1
|
Wang Z, Li M, Ji H, Chen H, Sang A, Cheng X, Li J, Yu Y. Comparison of risk factors for OBL in FS-LASIK and SMILE correction for myopia and myopia astigmatism. Graefes Arch Clin Exp Ophthalmol 2024; 262:1925-1931. [PMID: 38091059 DOI: 10.1007/s00417-023-06336-2] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/24/2023] [Revised: 10/26/2023] [Accepted: 11/30/2023] [Indexed: 05/22/2024] Open
Abstract
BACKGROUND To find out the incidence and risk factors of opaque bubble layer (OBL) in eyes with myopia and myopic astigmatism following femtosecond laser-assisted in situ keratomileusis (FS-LASIK) and small incision lenticule extraction (SMILE). METHODS A total of 1076 eyes from 569 patients who had FS-LASIK or SMILE were included in the retrospective research. For each kind of surgery, eyes were separated into two groups: "OBL" groups and "no OBL" groups. In the FS-LASIK group, eyes that developed OBL were split into "hard OBL" and "soft OBL" groups. The incidence and size of OBL were analyzed after watching the surgical procedure videotaped during the operation and taking screenshots. Surgical parameters, including sphere, cylinder, keratometry, corneal thickness, flap thickness, cap thickness, lenticule thickness, and visual acuity, were compared. RESULTS In the FS-LASIK surgery, the incidence of OBL was 63.2% (347 eyes). A thicker central corneal thickness (CCT) was the only independent risk factor affecting the OBL area (β = 0.126, P = 0.019). One hundred and thirty of these eyes had hard OBL, and the flap thickness of these eyes was thinner than that of those with soft OBL (P = 0.027). In the SMILE group, 26.6% (140 eyes) developed OBL. A higher flat keratometry (K) and a thicker residual stromal thickness (RST) were risk factors affecting the OBL area (β = 0.195, P = 0.024; β = 0.281, P = 0.001). CONCLUSION The incidence of OBL differs between the FS-LASIK surgery and the SMILE surgery. There are differences in the factors influencing OBL between the two surgeries.
Collapse
Affiliation(s)
- Zichen Wang
- Eye Institute, Affiliated Hospital of Nantong University, Medical School of Nantong University, No. 20, Xisi Road, Nantong City, 226001, Jiangsu Province, China
| | - Mingrui Li
- Eye Institute, Affiliated Hospital of Nantong University, Medical School of Nantong University, No. 20, Xisi Road, Nantong City, 226001, Jiangsu Province, China
| | - Haixia Ji
- Eye Institute, Affiliated Hospital of Nantong University, Medical School of Nantong University, No. 20, Xisi Road, Nantong City, 226001, Jiangsu Province, China
| | - Hui Chen
- Eye Institute, Affiliated Hospital of Nantong University, Medical School of Nantong University, No. 20, Xisi Road, Nantong City, 226001, Jiangsu Province, China
| | - Aimin Sang
- Eye Institute, Affiliated Hospital of Nantong University, Medical School of Nantong University, No. 20, Xisi Road, Nantong City, 226001, Jiangsu Province, China
| | - Xinliang Cheng
- Eye Institute, Affiliated Hospital of Nantong University, Medical School of Nantong University, No. 20, Xisi Road, Nantong City, 226001, Jiangsu Province, China
| | - Jun Li
- Department of Dermatology, Nantong First People's Hospital, Second Affiliated Hospital of Nantong University, Nantong, 226001, China
| | - Ying Yu
- Eye Institute, Affiliated Hospital of Nantong University, Medical School of Nantong University, No. 20, Xisi Road, Nantong City, 226001, Jiangsu Province, China.
| |
Collapse
|
2
|
Yusef YN, Ermakova SV, Sheludchenko VM, Surnina ZV. [Functional outcomes and corneal condition in cavitation complications of femtosecond LASIK]. Vestn Oftalmol 2024; 140:78-86. [PMID: 39569779 DOI: 10.17116/oftalma202414005178] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/22/2024]
Abstract
The use of femtosecond (FS) laser in LASIK procedures for myopia correction can lead to the formation of an opaque bubble layer (OBL) in stromal layers of different densities and in various areas of the cornea. PURPOSE This study evaluated the functional outcomes and the condition of the cornea in eyes with and without OBL in randomized groups. MATERIAL AND METHODS The study included 93 patients (186 eyes) with varying degrees of myopia (from 2.25 to 7.5 D): the main group consisted of 137 eyes with OBL, the control group - 49 eyes without OBL. The average age of patients was 30±5 and 32±4 years, respectively, with spherical equivalent refractive errors of -4.9 D and -4.3 D, astigmatism up to 1.75 D and 1.25 D, respectively. The assessment included uncorrected visual acuity (UCVA), best corrected visual acuity (BCVA), clinical refraction, lower-order aberrations (RMS LOA), higher-order aberrations (RMS HOA), spherical aberration (Z40; Pentacam HR Oculus), confocal microscopy of all corneal layers, and tear film assessment (Medmont; TFSQ; TFBUT; TFSQ area). All patients underwent FS-LASIK [Technolas VICTUS; corneal flap thickness of 110-120 μm (optical zone 6.0 mm), pulse energy >1 mJ, frequency 80 kHz]. Follow-up visits were conducted at day 7, and 1, 3, and 6 months. RESULTS No statistically significant differences were observed between the groups in terms of functional outcomes and optical aberrations. However, the OBL group showed significantly higher TFSQ values and more pronounced keratocyte changes visualized in the deep stromal layers (under the OBL) at the depth of 130-160 μm. The extent of keratocyte alterations decreased over time, from 118.3±5.1 mm/mm² on day 7 to 71.1±4.8 mm/mm² at 6 months, as observed via confocal microscopy. CONCLUSION While there was no difference in functional outcomes for myopia correction between eyes with and without OBL, the presence of OBL was associated with a higher extent of destructive changes in keratocytes, necessitating a longer healing period.
Collapse
Affiliation(s)
- Yu N Yusef
- Krasnov Research Institute of Eye Diseases, Moscow, Russia
| | - S V Ermakova
- Krasnov Research Institute of Eye Diseases, Moscow, Russia
| | | | - Z V Surnina
- Krasnov Research Institute of Eye Diseases, Moscow, Russia
| |
Collapse
|
3
|
Yang S, Wang H, Chen Z, Li Y, Chen Y, Long Q. Possible risk factors of opaque bubble layer and its effect on high-order aberrations after small incision Lenticule extraction. Front Med (Lausanne) 2023; 10:1156677. [PMID: 38179268 PMCID: PMC10765512 DOI: 10.3389/fmed.2023.1156677] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/01/2023] [Accepted: 11/30/2023] [Indexed: 01/06/2024] Open
Abstract
Purpose To evaluate the possible risk factors of opaque bubble layer (OBL) formation in small incision lenticule extraction (SMILE) surgery and its effects on visual quality. Methods Fifty-six eyes from 28 patients were included in this study. The preoperative parameters and intraoperative designs were recorded. Corneal high-order aberrations (HOAs), point spread function (PSF), and modulation transfer function (MTF) were measured using iTrace at pre-operation, 1 week, 1 month, and 3 months after SMILE. Generalized Estimating Equation and Linear Mixed Effects Model were employed for statistical analysis. Results The mean OBL area in SMILE surgery was 2.75% ± 1.25%. The patients were divided into groups based on whether the OBL was greater than the mean group or less than the mean group. Compared to the group with a smaller OBL area, the group with the larger OBL area had steeper corneal curvature and thinner cap thickness, the OBL area was positively correlated with the preoperative keratometry (r = 0.21, p = 0.04) and preoperative spherical value (r = 0.47, p = 0.01). The group with the larger OBL area induced more corneal SA and trefoil at 1 week postoperatively, but the difference was not significant at 1 month and 3 months postoperatively. Conclusion A steep corneal curvature, thin cap thickness, and high preoperative spherical value are possible risk factors for OBL formation in SMILE surgery. The OBL increased the ocular and corneal HOAs postoperatively for a short period (1 week), while it did not affect the long-term outcomes.
Collapse
Affiliation(s)
| | | | | | | | - Youxin Chen
- Department of Ophthalmology, Peking Union Medical College Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing, China
| | - Qin Long
- Department of Ophthalmology, Peking Union Medical College Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing, China
| |
Collapse
|
4
|
VisuMax Flap 2.0: a flap plus technique to reduce incidence of an opaque bubble layer in femtosecond laser–assisted LASIK. Graefes Arch Clin Exp Ophthalmol 2022; 261:1187-1194. [PMID: 36374312 PMCID: PMC10049947 DOI: 10.1007/s00417-022-05894-1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/04/2022] [Revised: 10/18/2022] [Accepted: 11/03/2022] [Indexed: 11/16/2022] Open
Abstract
Abstract
Purpose
To evaluate the incidence of an opaque bubble layer (OBL) in femtosecond laser–assisted in situ keratomileusis (FS-LASIK) flaps created with VisuMax Flap 2.0 as a result of a modification in the parameters of the flap programming.
Methods
This retrospective study was comprised of 1400 eyes of 715 patients who received FS-LASIK surgery. OBLs were measured and reported as a percentage of the flap area to identify the incidence and extent. Flap creation, which is a modification technique, was performed with 8.1-mm flap diameters plus 0.3-mm enlarged interlamellar photodisruption (group Flap 2.0). The same flap diameters without extra photodisruption as the previous standard setting were also implemented (group Flap 1.0). The preoperative measurements, including sphere, cylinder, keratometry, and intraoperative characteristics such as flap size and thickness, were documented. Possible risk factors for the occurrence of OBLs were investigated in this study.
Results
The incidence of an OBL was reduced when using the Flap 2.0 program (31.4%) compared to the Flap 1.0 program (63.7%). The area of hard and soft OBLs created by the Flap 2.0 program is smaller than those created by the Flap 1.0 program (P = 0.007 and P < 0.001). Multivariate logistic regression indicated that a thinner flap (P = 0.038) and a higher sphere (P = 0.001) affected the chance of hard OBLs occurring.
Conclusion
The VisuMax Flap 2.0 program promotes gas venting by enlarging the interlamellar photodisruption size. The incidence and extent of OBLs appear to be reduced significantly when the Flap 2.0 program is applied.
Collapse
|
5
|
He X, Li SM, Zhai C, Zhang L, Wang Y, Song X, Wang Y. Flap-making patterns and corneal characteristics influence opaque bubble layer occurrence in femtosecond laser-assisted laser in situ keratomileusis. BMC Ophthalmol 2022; 22:300. [PMID: 35820852 PMCID: PMC9277786 DOI: 10.1186/s12886-022-02524-6] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/20/2022] [Accepted: 07/07/2022] [Indexed: 11/18/2022] Open
Abstract
Background Opaque bubble layer (OBL), which generates from photo-disruptive procedures on the cornea, has been a common phenomenon during femtosecond laser-assisted refractive surgeries and it would potentially impact eye tracking and flap lifting. And we have observed that an updated flap-making pattern could form less OBL clinically than the traditional pattern, which needed further approval. Thus, the purpose of this study is to prove our observation and investigate the possible risk factors related to the occurrence and type of OBL in laser in situ keratomileusis (LASIK) flaps using the Visumax laser system. Methods This prospective study included 167 eyes of 86 patients (mean age: 27.5 ± 6.1 years) undergoing bilateral femtosecond laser-assisted laser in situ keratomileusis (FS-LASIK) for myopia/myopic astigmatism by the same surgeon from April 2020 to August 2020. Preoperative data on refraction, central corneal thickness (CCT), and keratometry as well as intraoperative data were included for analysis. A new flap-making pattern creating an offset between flap-cut and side-cut was adopted to compare with the traditional pattern. The operation video of flap formation was analyzed to identify the existence and type of OBL. The area covered by OBL and the ratio of OBL to flap were calculated using Image J software. Results Among 167 eyes, 54 eyes (32.3%) developed OBLs, consisting of 31 as hard OBL coexisting with soft OBL, and 23 as soft OBL alone. The OBL incidence was significantly reduced in eyes with the new flap-making pattern compared with the traditional pattern (13.8% vs. 52.5%, P < 0.001). Hard OBLs had larger area ratios than soft OBLs (14.3 ± 8.3% vs. 1.1 ± 1.8%, P < 0.001). Univariate analyses revealed that eyes with more myopia, thicker CCT, and traditional flap-making patterns were more likely to develop OBLs. Multivariate analysis further confirmed that more myopia, thicker CCT, and traditional flap-making pattern were risk factors for OBLs. A Larger corneal diameter was associated with a higher incidence of hard OBL when applying the traditional flap-making process. Conclusion More myopia, thicker CCT, and larger corneal diameter were risk factors for OBL development during flap creation, whereas a flap-making pattern with an offset between flap-cut and side-cut could reduce the incidence of OBL.
Collapse
Affiliation(s)
- Xi He
- Beijing Tongren Eye Center, Beijing Tongren Hospital, Capital Medical University; Beijing Ophthalmology & Visual Sciences Key Laboratory, Beijing, 100730, China
| | - Shi-Ming Li
- Beijing Tongren Eye Center, Beijing Tongren Hospital, Capital Medical University; Beijing Ophthalmology & Visual Sciences Key Laboratory, Beijing, 100730, China.
| | - Changbin Zhai
- Beijing Tongren Eye Center, Beijing Tongren Hospital, Capital Medical University; Beijing Ophthalmology & Visual Sciences Key Laboratory, Beijing, 100730, China.
| | - Li Zhang
- Beijing Tongren Eye Center, Beijing Tongren Hospital, Capital Medical University; Beijing Ophthalmology & Visual Sciences Key Laboratory, Beijing, 100730, China
| | - Yue Wang
- Beijing Tongren Eye Center, Beijing Tongren Hospital, Capital Medical University; Beijing Ophthalmology & Visual Sciences Key Laboratory, Beijing, 100730, China
| | - Xiumei Song
- Beijing Tongren Eye Center, Beijing Tongren Hospital, Capital Medical University; Beijing Ophthalmology & Visual Sciences Key Laboratory, Beijing, 100730, China
| | - Yi Wang
- Beijing Tongren Eye Center, Beijing Tongren Hospital, Capital Medical University; Beijing Ophthalmology & Visual Sciences Key Laboratory, Beijing, 100730, China
| |
Collapse
|
6
|
A Comparative Study of Laser In Situ Keratomileusis Flaps Created Using Single-Functional Versus Multifunctional Femtosecond Laser for Refractive Surgery. Cornea 2021; 39:1122-1131. [PMID: 32472791 DOI: 10.1097/ico.0000000000002353] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
Abstract
PURPOSE To compare laser in situ keratomileusis flaps created at the programmed target thickness of 120 μm using the LenSx multifunctional and the FS200 single-functional femtosecond lasers as evaluated by anterior segment optical coherence tomography (AS-OCT). METHODS This was a prospective, comparative, consecutive, blinded, nonrandomized study. Patients with stable refraction for over a year were consecutively allocated to the LenSx group or the FS200 group (n = 66; 33 patients in each group). All the patients underwent refractive surgery in both eyes. Previous eye surgery, ocular pathology associated with refractive errors, pregnancy, breastfeeding, and use of medication that causes ocular adverse effects constituted the exclusion criteria. Corneal topography, corneal tomography, dilated fundoscopy, applanation tonometry, ultrasonic pachymetry, dynamic and static refraction, visual acuity, and AS-OCT were evaluated before and after surgery. AS-OCT flap thickness was measured at 20 points on each cornea. RESULTS In the LenSx group, AS-OCT flap thickness differed significantly from the target thickness at 2 of 20 points (mean differences of 2.106 and 1.803 μm). In the FS200 group, 6 of 20 measurements differed significantly (mean differences ranging from 1.121 to 2.121 μm). The 2 lasers were similarly successful in creating regular and uniform flaps. The agreement between the 2 blinded examiners regarding the AS-OCT flap thickness measurements was excellent (intraclass correlation coefficient >0.75) in both groups. CONCLUSIONS Both femtosecond lasers were safe and capable of creating highly reproducible, uniform, and regular flaps at the target preoperative thickness of 120 μm. The LenSx multifunctional femtosecond laser offers the advantage of allowing both cataract and corneal surgeries.
Collapse
|
7
|
Brar S, Ganesh S, Gautam M, Devi RC. Comparison of Clinical Outcomes and Visual Quality Using a Medium Versus Small Contact Glass in Patients Undergoing SMILE With Large Corneal Diameters. J Refract Surg 2021; 37:150-157. [PMID: 34038297 DOI: 10.3928/1081597x-20201222-02] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
Abstract
PURPOSE To compare the clinical outcomes and visual quality using a small (S) versus medium (M) size contact glass in eyes with large white-to-white (WTW) distance undergoing bilateral small incision lenticule extraction (SMILE) for myopia correction. METHODS This contralateral eye study involved 60 eyes of 30 patients (mean age: 27.20 years) undergoing bilateral SMILE for myopia/myopic astigmatism with a WTW distance of 12 mm or greater in both eyes, which were randomized to receive treatment with an S-contact glass in one eye and an M-contact glass in the fellow eye. Opaque bubble layer (OBL) was graded using a new grading system. On postoperative 1 day, 2 weeks, and 3 months, UDVA, CDVA, contrast sensitivity, Objective Scatter Index, and modulation transfer function cut-off values were compared between the two groups. RESULTS The mean OBL score was significantly lower in the S-contact glass group (28.18%) compared to the M-contact glass group (67.13%) (P < .01). At 1 day postoperatively, the UDVA, Objective Scatter Index score, and contrast sensitivity values for all spatial frequencies were significantly better in eyes treated with the S-contact glass compared to the M-contact glass (P ⩽ .05). At 3 months postoperatively, however, the UDVA, Objective Scatter Index score, modulation transfer function cut-off, and contrast sensitivity values were comparable for both groups. No eye in either group had intraoperative complications such as suction loss, incision/lenticule tears, or lenticule retention. CONCLUSIONS In corneas with a WTW distance of 12 mm or greater, docking with the S-contact glass resulted in significantly better immediate visual results due to less OBL formation and smoother tissue dissection compared to the M-contact glass. [J Refract Surg. 2021;37(3):150-157.].
Collapse
|
8
|
Freidank S, Vogel A, Linz N. Optical Vortex Beam for Gentle and Ultraprecise Intrastromal Corneal Dissection in Refractive Surgery. Transl Vis Sci Technol 2020; 9:22. [PMID: 33024615 PMCID: PMC7521178 DOI: 10.1167/tvst.9.10.22] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/28/2020] [Accepted: 08/20/2020] [Indexed: 11/24/2022] Open
Abstract
Purpose We introduce a novel focus shaping concept for intrastromal corneal dissection that facilitates cleavage along corneal lamellae, and we analyze laser-tissue interactions governing cutting effectiveness and mechanical side effects. Methods Focus shaping was achieved by a spiral phase plate that converts an incident Gaussian beam into a Laguerre-Gaussian beam with a helical phase. Such vortex beams have zero intensity at their center, are propagation invariant, and possess a ring focus equal in length to the Gaussian focus but with a larger diameter. Cutting precision and the required absorbed energy for flap dissection were compared for Gaussian and vortex beams on ex vivo porcine corneal specimens at pulse durations between 480 fs and 9 ps. Cutting quality and bubble formation were characterized by scanning electron microscopy and macro photography. Results With the vortex beam, the cuts were much smoother. Bubble formation was markedly reduced because cutting can be performed close to the bubble threshold, whereas with the Gaussian beam energies well above threshold are needed. Although the incident energy at the flap dissection threshold was slightly larger for the vortex beam, the absorbed energy was much smaller and contributed more effectively to cutting. This reduced plasma-induced pressure more than sevenfold. Conclusions The vortex beam approach for corneal dissection is a simple, versatile, and cost-effective way of improving the precision of refractive surgery while reducing bubble formation and pressure-related mechanical side effects. Translational Relevance Phase plates for propagation invariant vortex beams are easily implemented in the beam path of next-generation clinical devices.
Collapse
Affiliation(s)
| | - Alfred Vogel
- Institute of Biomedical Optics, University of Luebeck, Luebeck, Germany
| | - Norbert Linz
- Institute of Biomedical Optics, University of Luebeck, Luebeck, Germany
| |
Collapse
|
9
|
Tăbăcaru B, Stanca S, Mocanu V, Zemba M, Stanca HT, Munteanu M. Intraoperative flap-related complications in FemtoLASIK surgeries performed with Visumax ® femtosecond laser: A ten-year Romanian experience. Exp Ther Med 2020; 20:2529-2535. [PMID: 32765745 PMCID: PMC7401922 DOI: 10.3892/etm.2020.8907] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/06/2020] [Accepted: 06/05/2020] [Indexed: 12/19/2022] Open
Abstract
Incidence and clinical results of intraoperative flap and interface-related complications were investigated after Femtosecond-LASIK surgery, where flap creation was performed with VisuMax® femtosecond laser. A retrospective 10-year cohort study was conducted including all eyes treated for all refractive errors by Femtosecond-LASIK technique. All the flaps were made by the same refractive surgeon with the VisuMax® (Carl Zeiss Meditec) femtosecond laser. We report the intraoperative flap and interface-related complications in these eyes, also describing their management. The study included 4,032 eyes. Flap and interface-related complications were: opaque bubble layer (OBL) 21.18%, suction loss 1.29%, difficult docking 0.69%, difficult dissection of the flap 0.59%, bleeding from limbal blood vessels 0.35%, de-epithelialization of the flap 0.12%, and interface debris 0.025%. These situations were appropriately addressed, with favorable outcomes. Flap creation is an important step in LASIK surgery. The predictability and safety have improved since the flap incision is assisted by a femtosecond laser, but complications of the flap and interface can still occur during the flap creation. Refractive surgeons should be aware and properly manage any unusual situation.
Collapse
Affiliation(s)
- Bogdana Tăbăcaru
- Department of Ophthalmology, 'Carol Davila' University of Medicine and Pharmacy, 050474 Bucharest, Romania
| | - Simona Stanca
- Department of Pediatrics, 'Carol Davila' University of Medicine and Pharmacy, 050474 Bucharest, Romania
| | - Valeria Mocanu
- Department of Ophthalmology, 'Victor Babes' University of Medicine and Pharmacy, 300041 Timisoara, Romania
| | - Mihail Zemba
- Department of Ophthalmology, 'Carol Davila' University of Medicine and Pharmacy, 050474 Bucharest, Romania
| | - Horia Tudor Stanca
- Department of Ophthalmology, 'Carol Davila' University of Medicine and Pharmacy, 050474 Bucharest, Romania
| | - Mihnea Munteanu
- Department of Ophthalmology, 'Victor Babes' University of Medicine and Pharmacy, 300041 Timisoara, Romania
| |
Collapse
|
10
|
Wei CH, Dai QY, Mei LX, Ge Y, Zhang PF, Song E. Paired eye-control study of unilateral opaque bubble layer in femtosecond laser assisted laser in situ keratomileusis. Int J Ophthalmol 2019; 12:654-659. [PMID: 31024822 DOI: 10.18240/ijo.2019.04.21] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/05/2018] [Accepted: 10/19/2018] [Indexed: 11/23/2022] Open
Abstract
AIM To investigate the predictive factors of the opaque bubble layer (OBL) compared to the fellow eye of same patients in FS200 femtosecond laser assisted laser in situ keratomileusis (FS-LASIK). METHODS This study consisted of 60 consecutive patients (120 eyes) with unilateral OBL during FS-LASIK. Eyes were divided into OBL (the OBL eyes) and OBL-free groups (the fellow eyes) based on the occurrence of OBL. The preoperative demographic data, refraction, keratometry, corneal astigmatism, pachymetry, intraocular pressure and intraoperative data including the outlet location of gas diffusing canal were collected. Conditional logistic regression analysis was performed to find the associated factors with OBL in the two groups by determining odds ratios (OR) and 95%CI. RESULTS The preoperative demographic data, mean spherical errors, mean K value, suction time, intraocular pressure and central cornea thickness were not significantly different between the two groups. The outlet location of gas diffusing canal (P<0.01, OR 7.16, 95%CI 2.53-20.32) and the corneal astigmatism (P=0.013, OR 0.13, 95%CI 0.03-0.65) were significantly associated with the incidence of OBL by multivariate logistic regression analysis. Visual acuity, efficacy, and safety were comparable between the two groups two months after surgery except for a slightly lower predictability value for the hard OBL eyes. CONCLUSION The reduction of the incidence of OBL is obvious when the outlet of gas diffusing canal located at the posterior border of the corneoscleral limbus. This is probably consequent to more effectiveness of gas diffusing canal. Corneal astigmatism is also an independent protective factor for OBL formation.
Collapse
Affiliation(s)
- Cheng-Hua Wei
- Department of Ophthalmology, the Second Affiliated Hospital of Soochow University, Suzhou 215004, Jiangsu Province, China.,Department of Ophthalmology, the First Affiliated Hospital of Wannan Medical College, Wuhu 241000, Anhui Province, China
| | - Qiao-Yun Dai
- Department of Ophthalmology, the First Affiliated Hospital of Wannan Medical College, Wuhu 241000, Anhui Province, China
| | - Li-Xin Mei
- Department of Ophthalmology, the First Affiliated Hospital of Wannan Medical College, Wuhu 241000, Anhui Province, China
| | - Yao Ge
- Department of Ophthalmology, the First Affiliated Hospital of Wannan Medical College, Wuhu 241000, Anhui Province, China
| | - Peng-Fei Zhang
- Department of Ophthalmology, the First Affiliated Hospital of Wannan Medical College, Wuhu 241000, Anhui Province, China
| | - E Song
- Department of Ophthalmology, Lixiang Eye Hospital of Soochow University, Suzhou 215021, Jiangsu Province, China
| |
Collapse
|
11
|
Reinstein DZ, Carp GI, Archer TJ, Day AC, Vida RS. Outcomes for Mixed Cylinder LASIK With the MEL 90 ® Excimer Laser. J Refract Surg 2019; 34:672-680. [PMID: 30296328 DOI: 10.3928/1081597x-20180814-01] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/01/2018] [Accepted: 07/25/2018] [Indexed: 11/20/2022]
Abstract
PURPOSE To report the outcomes of LASIK for mixed cylinder using the Triple-A ablation profile with the MEL 90 excimer laser (Carl Zeiss Meditec, Jena, Germany). METHODS This was a retrospective analysis of all eyes treated by LASIK for mixed cylinder using the Triple-A ablation profile with the MEL 90 laser between July 2013 and October 2016. Patients were observed for 1 year after surgery. Standard outcomes analysis and vector analysis by the Alpins method were performed. RESULTS The database review identified 105 eyes (82 patients) treated by LASIK for mixed cylinder using the MEL 90 laser. Mean age was 40 ± 11 years (range: 18 to 65 years). Mean attempted spherical equivalent was +0.30 ± 0.90 diopters (D) (range: -2.30 to +1.75 D). Mean cylinder was -2.93 ± 1.47 D (range: -0.75 to -7.00 D). Preoperative corrected distance visual acuity (CDVA) was 20/20 or better in 81% of eyes. Postoperative uncorrected distance visual acuity was 20/20 or better in 69% and 20/25 or better in 86% of eyes. Mean postoperative spherical equivalent relative to the intended target was -0.21 ± 0.38 D (range: -1.25 to +1.13 D), with 83% within ±0.50 D. Mean postoperative cylinder was -0.57 ± 0.41 D (range: 0.00 to -1.75 D). Geometric mean was 1.12 for the correction index and 0.25 for the index of success. For angle of error, the arithmetic mean was -0.6° ± 4.2° (range: -13.5° to 9.5°) and the absolute mean was 2.9° ± 3.0° (range: 0.0° to 13.5°). There was loss of one line of CDVA in 3% of eyes and no eyes lost two or more lines CDVA. There was a small increase in contrast sensitivity after surgery at 3, 6, 12, and 18 cycles per degree (P < .05). CONCLUSIONS One-year outcomes of LASIK using the MEL 90 laser for mixed cylinder up to -7.00 D demonstrated excellent efficacy, safety, and predictability. Vector analysis found a 12% overcorrection in magnitude of refractive cylinder. Given the high accuracy for angle of error, a nomogram could be applied to reduce the over-correction and further improve the uncorrected distance visual acuity outcomes. [J Refract Surg. 2018;34(10):672-680.].
Collapse
|
12
|
Reinstein DZ, Carp GI, Archer TJ, Day AC, Vida RS. Outcomes for Hyperopic LASIK With the MEL 90 ® Excimer Laser. J Refract Surg 2019; 34:799-808. [PMID: 30540362 DOI: 10.3928/1081597x-20181019-01] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/24/2018] [Accepted: 10/10/2018] [Indexed: 11/20/2022]
Abstract
PURPOSE To report the outcomes of laser in situ keratomileusis (LASIK) for hyperopia using the Triple-A ablation profile with the MEL 90 excimer laser (Carl Zeiss Meditec, Jena, Germany). METHODS This retrospective analysis included 1,383 eyes treated by LASIK for hyperopia using the Triple-A ablation profile with the MEL 90 at London Vision Clinic, London, United Kingdom, between September 2013 and December 2016. Inclusion criteria were attempted hyperopic correction of +0.25 diopters (D) or higher and corrected distance visual acuity (CDVA) of 20/40 or better. Patients were observed for 1 year after surgery. Standard outcomes analysis was performed. RESULTS One-year data were available for 1,350 (97%) eyes. Mean attempted spherical equivalent refraction (SEQ) was +2.77 ± 1.34 D (range: +0.13 to +6.50 D) and mean cylinder was -0.67 ± 0.66 D (range: 0.00 to -5.00 D). Mean age was 54 ± 11 years (range: 21 to 75 years), and 57% were female. Postoperative spherical equivalent was ±0.50 D in 73% and ±1.00 D in 93% of eyes. Uncorrected distance visual acuity was 20/20 or better in 75% of eyes, relative to 93% with preoperative CDVA of 20/20 or better. One line of CDVA was lost in 17% of eyes and two lines were lost in 0.6% of eyes. There was a clinically insignificant but statistically significant increase (P < .01) in contrast sensitivity at 3 and 6 cycles per degree (cpd) and no change for 12 and 18 cpd. CONCLUSIONS LASIK for hyperopia with the MEL 90 excimer laser was found to satisfy accepted criteria for safety, efficacy, and stability. [J Refract Surg. 2018;34(12):799-808.].
Collapse
|
13
|
Reinstein DZ, Carp GI, Archer TJ, Vida RS. Outcomes of Re-treatment by LASIK After SMILE. J Refract Surg 2018; 34:578-588. [PMID: 30199561 DOI: 10.3928/1081597x-20180717-02] [Citation(s) in RCA: 25] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/18/2018] [Accepted: 07/03/2018] [Indexed: 11/20/2022]
Abstract
PURPOSE To report the outcomes of LASIK re-treatments after small incision lenticule extraction (SMILE). METHODS Retrospective review of all eyes to have undergone a re-treatment by LASIK after primary SMILE between September 2013 and January 2016. Thin-flap LASIK was used in most cases as long as sufficient tissue was available for safe flap creation between the maximum epithelial thickness and minimum cap thickness. Otherwise, the SMILE interface was converted into a LASIK flap by the Circle technique or side cut only. The multivariate nomogram for LASIK re-treatments was used, including sphere, cylinder, age, and primary spherical equivalent (SEQ) as variables. Patients were observed for 1 year after surgery and standard outcomes analysis was performed. RESULTS A total of 116 LASIK re-treatments were performed in a population of 2,643 consecutive SMILE procedures, indicating a re-treatment rate of 4.39%. Mean attempted SEQ was -0.05 ± 0.99 diopters (D) (range: -1.88 to +1.50 D). Mean cylinder was -0.70 ± 0.55 D (range: 0.00 to -2.25 D). Postoperative uncorrected distance visual acuity was 20/20 or better in 81% of eyes, for a population with corrected distance visual acuity (CDVA) of 20/20 or better in 95% before re-treatment. Mean postoperative SEQ relative to the target was +0.19 ± 0.49 D (range: -0.88 to +2.13 D), with 74% within ±0.50 D. Mean postoperative cylinder was -0.29 ± 0.24 D (range: 0.00 to -1.25 D). There was one line loss of CDVA in 15% of eyes, but no eyes lost two or more lines. There was a small increase in contrast sensitivity (P < .05). Overcorrection was identified in myopic re-treatments (n = 20) of -1.00 D or more; mean postoperative SEQ was +0.59 ± 0.64 D (range: -0.63 to +2.13 D). CONCLUSIONS Re-treatment after SMILE by LASIK achieved excellent visual and refractive outcomes, although these results indicate that myopic LASIK retreatment after primary myopic SMILE requires a different nomogram than for myopic LASIK re-treatment after primary myopic LASIK. [J Refract Surg. 2018;34(9):578-588.].
Collapse
|
14
|
Reinstein DZ, Carp GI, Archer TJ, Vida RS. Inferior pseudo-hinge fulcrum technique and intraoperative complications of laser in situ keratomileusis retreatment after small-incision lenticule extraction. J Cataract Refract Surg 2018; 44:1355-1362. [PMID: 30287159 DOI: 10.1016/j.jcrs.2018.07.051] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/06/2018] [Revised: 07/05/2018] [Accepted: 07/17/2018] [Indexed: 11/28/2022]
Abstract
PURPOSE To describe the evolution of a flap-lift technique for laser in situ keratomileusis (LASIK) retreatment after small-incision lenticule extraction (SMILE) and report the incidence of complications. SETTING London Vision Clinic, London, United Kingdom. DESIGN Retrospective case series. METHODS All retreatments between September 2013 and January 2017 were included. A bimanual inferior pseudo-hinge fulcrum flap-lift technique was developed to minimize the chance of tearing or entering the small incision. A flap lifter and a McPherson forceps were inserted into the inferior one third of the flap, slightly angled up to avoid perforating the small-incision lenticule extraction interface. One instrument provided countertraction, and the second separated the interface superiorly, keeping the tip away from the incision. One instrument was held against the hinge for the second instrument to separate the inferior one third. The incidence of intraoperative complications was analyzed. RESULTS The study evaluated 162 retreatments (4.12%) for 3933 small-incision lenticule extraction treatments (1-year maturity). The retreatment was LASIK (n = 135), side-cut only (n = 1), cap-to-flap procedure (CIRCLE) (n = 3), or photorefractive keratectomy (n = 23). Two eyes (1.4%) had a tear to the small incision. The small-incision lenticule extraction interface was accessed in 8 eyes (5.8%), 1 (0.7%) centrally, and the interface was lifted in 1 eye (0.7%). There were no complications in the last 84 consecutive procedures (60%) using the finalized technique. CONCLUSION The bimanual inferior pseudo-hinge fulcrum decreased the risk for accessing the small-incision lenticule extraction interface or tearing the small incision.
Collapse
Affiliation(s)
- Dan Z Reinstein
- From the London Vision Clinic (Reinstein, Carp, Archer, Vida), London, and Biomedical Science Research Institute (Reinstein, Archer), University of Ulster, Coleraine, United Kingdom; Department of Ophthalmology (Reinstein), Columbia University Medical Center, New York, New York, USA; Centre Hospitalier National d'Ophtalmologie (Reinstein), Paris, France; Northern Ireland.
| | - Glenn I Carp
- From the London Vision Clinic (Reinstein, Carp, Archer, Vida), London, and Biomedical Science Research Institute (Reinstein, Archer), University of Ulster, Coleraine, United Kingdom; Department of Ophthalmology (Reinstein), Columbia University Medical Center, New York, New York, USA; Centre Hospitalier National d'Ophtalmologie (Reinstein), Paris, France; Northern Ireland
| | - Timothy J Archer
- From the London Vision Clinic (Reinstein, Carp, Archer, Vida), London, and Biomedical Science Research Institute (Reinstein, Archer), University of Ulster, Coleraine, United Kingdom; Department of Ophthalmology (Reinstein), Columbia University Medical Center, New York, New York, USA; Centre Hospitalier National d'Ophtalmologie (Reinstein), Paris, France; Northern Ireland
| | - Ryan S Vida
- From the London Vision Clinic (Reinstein, Carp, Archer, Vida), London, and Biomedical Science Research Institute (Reinstein, Archer), University of Ulster, Coleraine, United Kingdom; Department of Ophthalmology (Reinstein), Columbia University Medical Center, New York, New York, USA; Centre Hospitalier National d'Ophtalmologie (Reinstein), Paris, France; Northern Ireland
| |
Collapse
|
15
|
Li L, Schallhorn JM, Ma J, Zhang L, Dou R, Wang Y. Risk Factors for Opaque Bubble Layer in Small Incision Lenticule Extraction (SMILE). J Refract Surg 2017; 33:759-764. [DOI: 10.3928/1081597x-20170821-02] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/25/2017] [Accepted: 08/07/2017] [Indexed: 11/20/2022]
|
16
|
Wu N, Christenbury JG, Dishler JG, Bozkurt TK, Duel D, Zhang L, Hamilton DR. A Technique to Reduce Incidence of Opaque Bubble Layer Formation During LASIK Flap Creation Using the VisuMax Femtosecond Laser. J Refract Surg 2017; 33:584-590. [DOI: 10.3928/1081597x-20170621-06] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/09/2016] [Accepted: 06/07/2017] [Indexed: 11/20/2022]
|