1
|
Ohara H, Torikai T, Takeuchi J, Yokoi T, Koto T, Inoue M. Comparison of 27-Gauge to 25-Gauge Vitrectomy in Patients with Tractional Retinal Detachment Associated with Proliferative Diabetic Retinopathy. J Clin Med 2025; 14:2533. [PMID: 40217982 PMCID: PMC11989642 DOI: 10.3390/jcm14072533] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/06/2025] [Revised: 03/28/2025] [Accepted: 04/04/2025] [Indexed: 04/14/2025] Open
Abstract
Background/Objectives: To compare the surgical outcomes of 25-gauge (G) vitrectomy to those of 27G vitrectomy for proliferative diabetic retinopathy (PDR) with a tractional retinal detachment (TRD). Methods: Eighty-three consecutive eyes of 71 patients with PDR and TRD that underwent initial vitrectomy at the Kyorin Eye Center from June 2021 to August 2023 and were followed for ≥3 months were studied retrospectively. The surgical outcomes of the 10,000 cut/min (cpm) 25G vitrectomy (25G group, 25 eyes) to that of the 20,000 cpm 27G vitrectomy (27G group, 58 eyes) were compared. Results: The preoperative PDR status, surgical procedures, and postoperative outcomes were assessed relative to the surgical success. The 25G group had significantly more eyes with severe PDR (p = 0.010), no prior laser photocoagulation (p = 0.027), macular detachment (p = 0.006), and the use of bimanual technique (p = 0.005). However, the operative times and incidence of iatrogenic breaks were not significantly different. The visual acuity improved significantly in both groups at 3 months postoperatively. The primary anatomical success was 88% in the 25G and 97% in the 27G groups (p > 0.05). The risk factors for a postoperative retinal detachment were significantly associated with the grade (p = 0.042) and type of PDR (p = 0.041), the use of perfluorocarbon liquid (p = 0.028), and bimanual techniques (p = 0.017). Conclusions: The high anatomical success for both groups for TRD secondary to PDR indicates that both can be used to treat eyes with PDR. The 27G vitrectomy may reduce the need for bimanual techniques.
Collapse
Affiliation(s)
| | | | | | | | | | - Makoto Inoue
- Kyorin Eye Center, Kyorin University School of Medicine, 6-20-2 Shinkawa, Mitaka, Tokyo 186-8611, Japan (T.T.); (J.T.); (T.Y.); (T.K.)
| |
Collapse
|
2
|
Nishigushi R, Usui-Ouchi A, Sakanishi Y, Tamaki K, Mashimo K, Ito R, Sakuma T, Ebihara N, Nakao S. Outcomes, efficacy and risk factors of 27-Gauge vitrectomy for diabetic tractional retinal detachment in Japanese patients. Jpn J Ophthalmol 2025; 69:59-65. [PMID: 39503819 PMCID: PMC11821670 DOI: 10.1007/s10384-024-01135-6] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/07/2024] [Accepted: 09/26/2024] [Indexed: 02/13/2025]
Abstract
PURPOSE Diabetic retinopathy leads to vision-threatening complications, such as proliferative diabetic retinopathy and tractional retinal detachment (TRD) and is a major global health concern. Despite advancements in vitrectomy techniques, challenges exist in managing postoperative complications and long-term visual acuity. This study aimed to evaluate postoperative outcomes of 27-gauge pars plana vitrectomy (27 g PPV) for diabetic TRD and identify associated risk factors. STUDY DESIGN Retrospective study. METHODS This study included 94 eyes of 74 patients who underwent 27 g PPV for diabetic TRD between July 2017 and September 2022 at Juntendo University Urayasu Hospital, Japan. Patient demographics, preoperative characteristics, intraoperative details, and postoperative outcomes were examined. Statistical analyses were performed to identify factors influencing postoperative visual acuity. RESULTS Mean follow-up duration was 23.1 ± 14.6 months. Postoperatively, visual acuity (LogMAR) improved significantly from 1.34 ± 0.82 to 0.65 ± 0.79 (P < 0.0001). Postoperative complications included persistent vitreous hemorrhage (15%) and neovascular glaucoma (4%). Final retinal reattachment rate was 97%. Preoperatively, macular detachment (P < 0.0001) and Grade IV TRD (P < 0.0001) severity were significantly associated with poor final best corrected visual acuity (P < 0.0001). Preoperative macular detachment (P < 0.0001), Grade IV TRD (P < 0.0001), intraoperative iatrogenic breaks (P = 0.031), and postoperative neovascular glaucoma (P < 0.0001) were identified as significant predictors of poor postoperative visual outcomes through multivariate analysis. CONCLUSION This study highlights the efficacy of 27 g PPV in improving visual acuity in patients with diabetic TRD. Despite favorable outcomes, attention to preoperative risk factors and meticulous surgical techniques remain crucial for optimizing long-term visual prognosis in these patients.
Collapse
Affiliation(s)
- Risa Nishigushi
- Department of Ophthalmology, Juntendo University Urayasu Hospital, 2-1-1 Tomioka, Urayasu, Chiba, 279-0021, Japan
- Department of Ophthalmology, St. Luke's International Hospital, Tokyo, Japan
| | - Ayumi Usui-Ouchi
- Department of Ophthalmology, Juntendo University Urayasu Hospital, 2-1-1 Tomioka, Urayasu, Chiba, 279-0021, Japan.
| | - Yoshihito Sakanishi
- Department of Ophthalmology, Juntendo University Urayasu Hospital, 2-1-1 Tomioka, Urayasu, Chiba, 279-0021, Japan
| | - Kazunori Tamaki
- Department of Ophthalmology, Juntendo University Urayasu Hospital, 2-1-1 Tomioka, Urayasu, Chiba, 279-0021, Japan
| | - Keitaro Mashimo
- Department of Ophthalmology, Juntendo University Urayasu Hospital, 2-1-1 Tomioka, Urayasu, Chiba, 279-0021, Japan
| | - Rei Ito
- Department of Ophthalmology, Juntendo University Urayasu Hospital, 2-1-1 Tomioka, Urayasu, Chiba, 279-0021, Japan
| | - Toshiro Sakuma
- Department of Ophthalmology, Juntendo University Urayasu Hospital, 2-1-1 Tomioka, Urayasu, Chiba, 279-0021, Japan
| | - Nobuyuki Ebihara
- Department of Ophthalmology, Juntendo University Urayasu Hospital, 2-1-1 Tomioka, Urayasu, Chiba, 279-0021, Japan
| | - Shintaro Nakao
- Department of Ophthalmology, Juntendo University Graduate School of Medicine, 2-1-1 Hongo, Bunkyo-ku, Tokyo, 113-0033, Japan
| |
Collapse
|
3
|
Hannan A, Shaheen F, Saad M. Outcomes of 23-Gauge Pars Plana Vitrectomy in Various Vitreoretinal Diseases. Cureus 2024; 16:e72991. [PMID: 39634965 PMCID: PMC11616731 DOI: 10.7759/cureus.72991] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 11/03/2024] [Indexed: 12/07/2024] Open
Abstract
Background This study aimed to evaluate the safety, efficacy, and complications of 23-gauge (23-G) pars plana vitrectomy (PPV) in the treatment of various vitreoretinal diseases. Methodology A retrospective, cross-sectional study was conducted at Al-Shifa Trust Eye Hospital, Rawalpindi. All the eyes undergoing 23-G PPV between June 2020 and May 2023 meeting the inclusion criteria were included. Surgical outcomes and complications were assessed. Results A total of 350 eyes were included in our data. The most common indication was rhegmatogenous retinal detachment (RRD) (n = 144, 41.1%), followed by diabetic tractional retinal detachment (TRD) (n = 98, 21%). Satisfactory anatomical outcomes were achieved in all the indications. The primary success rate was 87.5% for RRD and 96.9% for TRD. The overall complication rate was 17.7%, with postoperative cataracts being the most frequent. Conclusions The 23-G PPV technique has proven to be a safe and effective approach for the surgical management of various vitreoretinal diseases, demonstrating favorable anatomical outcomes and a low rate of complications.
Collapse
Affiliation(s)
- Abdul Hannan
- Ophthalmology, Al-Shifa Trust Eye Hospital, Rawalpindi, PAK
| | - Fiza Shaheen
- Ophthalmology, Shifa International Hospital Islamabad, Islamabad, PAK
- Ophthalmology, Al-Shifa Trust Eye Hospital, Rawalpindi, PAK
| | - Muhammad Saad
- Ophthalmology, Al-Shifa Trust Eye Hospital, Rawalpindi, PAK
| |
Collapse
|
4
|
Xiang W, Fang D, Jiang X, Zhang Z, Xiang C, Huang S, Zhang S, Wei Y. 27‑Gauge vitrectomy vs. 25‑gauge vitrectomy in the management of proliferative diabetic retinopathy with preoperative intravitreal injection of conbercept. Exp Ther Med 2023; 26:472. [PMID: 37664677 PMCID: PMC10469386 DOI: 10.3892/etm.2023.12171] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/13/2023] [Accepted: 07/14/2023] [Indexed: 09/05/2023] Open
Abstract
Small-gauge vitrectomy has become popular due to its notable advantages, including less trauma, shortened convalescence and improved manoeuvrability. The aim of the present study was to compare the surgical outcomes of 27-gauge (27-G) vitrectomy with those of 25-gauge (25-G) vitrectomy in the management of proliferative diabetic retinopathy (PDR) with preoperative intravitreal injection of conbercept. The data of 48 consecutive patients with PDR (48 eyes) were retrospectively collected. The patients underwent conbercept intravitreal injection and pars plana vitrectomy with a 27-G group (23 eyes) or 25-G group (25 eyes) vitrectomy system. The operating time, suturing rate, endodiathermy rate, postoperative best-corrected visual acuity (BCVA), intraocular pressure (IOP) and complications were recorded. The mean postoperative BCVA at final follow-up was significantly improved compared with that at the baseline in both groups (P<0.001 for both). The differences in the mean BCVA changes between the two groups were not significant (P>0.99), and no differences were observed in the final central foveal thickness (P=0.51) between the two groups. The final IOP remained stable compared with that at the baseline in the 27-G group (P=0.36) and the 25-G group (P=0.05). The suturing rate was significantly decreased in the 27-G group compared with the 25-G group (P=0.04). There were no significant differences between the two groups in terms of the operating time (P=0.18), rate of endodiathermy use (P>0.99), iatrogenic retinal breaks (P=0.42) or postoperative recurrent vitreous haemorrhage (P>0.99). In addition, no case of ocular hypotony was observed in either group. In conclusion, 27-G vitrectomy was as efficient and safe as 25-G vitrectomy in the management of PDR in terms of operating time and complications. With reference to the literature, preoperative conbercept injection appears to assist in decreasing the incidence of intraoperative and postoperative complications.
Collapse
Affiliation(s)
- Wu Xiang
- State Key Laboratory of Ophthalmology, Zhongshan Ophthalmic Center, Sun Yat-sen University, Guangzhou, Guangdong 510060, P.R. China
| | - Dong Fang
- Shenzhen Eye Hospital Affiliated to Jinan University, Shenzhen, Guangdong 518040, P.R. China
| | - Xintong Jiang
- State Key Laboratory of Ophthalmology, Zhongshan Ophthalmic Center, Sun Yat-sen University, Guangzhou, Guangdong 510060, P.R. China
| | - Zhaotian Zhang
- State Key Laboratory of Ophthalmology, Zhongshan Ophthalmic Center, Sun Yat-sen University, Guangzhou, Guangdong 510060, P.R. China
| | - Chuqi Xiang
- State Key Laboratory of Ophthalmology, Zhongshan Ophthalmic Center, Sun Yat-sen University, Guangzhou, Guangdong 510060, P.R. China
| | - Shaofen Huang
- State Key Laboratory of Ophthalmology, Zhongshan Ophthalmic Center, Sun Yat-sen University, Guangzhou, Guangdong 510060, P.R. China
| | - Shaochong Zhang
- Shenzhen Eye Hospital Affiliated to Jinan University, Shenzhen, Guangdong 518040, P.R. China
| | - Yantao Wei
- State Key Laboratory of Ophthalmology, Zhongshan Ophthalmic Center, Sun Yat-sen University, Guangzhou, Guangdong 510060, P.R. China
| |
Collapse
|
5
|
Verma S, Shiny H, Azad SV, Kumar V. Evaluation of twenty-seven-gauge vitrectomy for complex proliferative diabetic retinopathy. Oman J Ophthalmol 2023; 16:18-22. [PMID: 37007246 PMCID: PMC10062110 DOI: 10.4103/ojo.ojo_348_21] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/25/2021] [Revised: 04/02/2022] [Accepted: 06/29/2022] [Indexed: 02/25/2023] Open
Abstract
PURPOSE To evaluate the outcomes of twenty-seven-gauge (27G) vitrectomy in cases with complex proliferative diabetic retinopathy (PDR). METHODS This was a retrospective interventional study of eyes that underwent 27G vitrectomy for complex PDR. The demographic profile, history, examination findings, and intraoperative surgical steps (especially use of other instruments such as intravitreal scissors/forceps) were reviewed. All the eyes were followed up for a minimum of 3 months at 1-week, 1-month, and 3-month interval. Visual acuity, intraocular pressure (IOP), and retinal status were documented at every follow-up. RESULTS Nineteen eyes of 17 patients with complex PDR were included in the study. Seven eyes had tractional retinal detachment involving the macula, three had tractional retinal detachment threatening the macula, one had secondary rhegmatogenous retinal detachment, and eight eyes had nonresolving vitreous hemorrhage along with thick fibrovascular proliferation (FVP) at posterior pole. Anatomical attachment was seen in all cases at the end of follow-up with a single surgery. Visual acuity improved from logMAR 2.5 preoperatively to logMAR 1.01 at 3 months (P = 0.0003). None of the cases required use of intravitreal scissors/forceps for the removal of FVP. Early postoperative vitreous hemorrhage was seen in two eyes. Hypotony was not seen in any eye, while increased IOP was seen in five eyes. CONCLUSION 27G vitrectomy is a safe and effective technique in cases with complex diabetic surgery. Due to smaller size cutter, it offers advantages in the dissection of tissue and is associated with lower incidence of early postoperative hemorrhage.
Collapse
Affiliation(s)
- Saurabh Verma
- Dr. Rajendra Prasad Centre for Ophthalmic Sciences, AIIMS, New Delhi, India
| | - Hannah Shiny
- Dr. Rajendra Prasad Centre for Ophthalmic Sciences, AIIMS, New Delhi, India
| | | | - Vinod Kumar
- Dr. Rajendra Prasad Centre for Ophthalmic Sciences, AIIMS, New Delhi, India
| |
Collapse
|
6
|
Xi C, Zhang Y, Yue J, Liu Y, Li M, Wang G. Same-Day Cancellation is Higher in Outpatient Pars Plana Vitrectomy for Proliferative Diabetic Retinopathy. Risk Manag Healthc Policy 2022; 15:1965-1974. [PMID: 36299661 PMCID: PMC9590320 DOI: 10.2147/rmhp.s378510] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/28/2022] [Accepted: 10/10/2022] [Indexed: 11/11/2022] Open
Abstract
Purpose Safety and efficiency of ambulatory pars plana vitrectomy (PPV) for proliferative diabetic retinopathy (PDR) patients is worthy of attention, since patients always have severe systemic diseases. The purpose of this study was to compare the incidence of same-day cancellation of PPV for PDR between outpatients and inpatients and to analyze the causes of cancellations. Patients and Methods This is a retrospective review of consecutive PPV procedures for PDR from January 2019 to April 2021 at either the ambulatory or the inpatient surgery center in an academic tertiary referral center. Data on patient surgery plan, same-day surgical cancellation and follow-up were recorded. Differences in cancellation rate and reasons for cancellation (e.g. medical factors, patient reasons and administrative problems) between outpatients and inpatients were compared. Results In total, 1810 consecutive PPV procedures of 1367 patients were identified; 1509 (83.4%) were managed as inpatient surgeries and 301 (16.6%) as outpatient surgeries. The total same-day cancellation rate was 5.2% for all patients. Although outpatients were younger (51 years vs 52 years, P < 0.001), had less proportion of hypertension (60.5% vs 74.0%), coronary artery disease (10.0% vs 18.8%), renal insufficiency (9.3% vs 18.0%) and cerebrovascular diseases (1.0% vs 11.4%) (all P < 0.001), had less proportion of patients with ASA III status (14.9% vs 27.4%, P < 0.001), and had higher proportion of regional anesthesia with MAC (19.9% vs 5.0%, P < 0.001), the cancellation proportion was significantly higher for outpatients than inpatients (12.3% vs 3.8%, P < 0.001). Overall, the most common reason for surgical cancellation was medical factors, occurring more frequently in outpatients than inpatients (91.9% vs 68.4%, P = 0.012). Conclusion Same-day cancellation is higher in outpatient pars plana vitrectomy for proliferative diabetic retinopathy. To reduce ambulatory surgery cancellations, it is important to strengthen the monitoring of preoperative systemic comorbidities and adjust medication if necessary.
Collapse
Affiliation(s)
- Chunhua Xi
- Department of Anesthesiology, Beijing Tongren Hospital, Capital Medical University, Beijing, People’s Republic of China
| | - Yi Zhang
- Department of Anesthesiology, Beijing Tongren Hospital, Capital Medical University, Beijing, People’s Republic of China
| | - Jianying Yue
- Department of Anesthesiology, Beijing Tongren Hospital, Capital Medical University, Beijing, People’s Republic of China
| | - Ying Liu
- Operation Center, Beijing Tongren Hospital, Capital Medical University, Beijing, People’s Republic of China
| | - Ming Li
- Department of Anesthesiology, Beijing Tongren Hospital, Capital Medical University, Beijing, People’s Republic of China
| | - Guyan Wang
- Department of Anesthesiology, Beijing Tongren Hospital, Capital Medical University, Beijing, People’s Republic of China,Correspondence: Guyan Wang, Department of Anesthesiology, Beijing Tongren Hospital, Capital Medical University, 1 Dongjiaominxiang Road, Dongcheng District, Beijing, 100730, People’s Republic of China, Tel +86-10-58268101, Email
| |
Collapse
|
7
|
Li D, Liu Y, Wu N. Application progress of nanotechnology in regenerative medicine of diabetes mellitus. Diabetes Res Clin Pract 2022; 190:109966. [PMID: 35718019 DOI: 10.1016/j.diabres.2022.109966] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/13/2022] [Revised: 03/20/2022] [Accepted: 06/13/2022] [Indexed: 11/28/2022]
Abstract
In recent years, the development of diabetic regenerative medicine has led to new developments and progress for the clinical treatment of diabetes mellitus and its various complications. Besides, the emergence of nanotechnology has injected new vitality into diabetic regenerative medicine. Nano-stent provides an appropriate direction for the regeneration of islet β cells, retinal tissue, nerve tissue, and wound tissue cells. Conductive nanomaterials promote various tissues' growth. Many nanoparticles also promote wound healing and present other advantages that have solved many potential problems in the practical application of regenerative medicine. In this review, we will summarize the application of nanotechnology in diabetic regenerative medicine.
Collapse
Affiliation(s)
- Danyang Li
- Department of Endocrinology, Shengjing Hospital of China Medical University, Shenyang 110004, PR China
| | - Yuxin Liu
- Student Affairs Department, Shengjing Hospital of China Medical University, Shenyang 110004, PR China
| | - Na Wu
- Department of Endocrinology, Shengjing Hospital of China Medical University, Shenyang 110004, PR China; Clinical Skills Practice Teaching Center, Shengjing Hospital of China Medical University, Shenyang 110004, PR China.
| |
Collapse
|
8
|
Clinical outcomes of a beveled tip, ultra-high speed, 25-gauge pars plana vitrectomy system. BMC Ophthalmol 2022; 22:93. [PMID: 35196996 PMCID: PMC8867727 DOI: 10.1186/s12886-022-02311-3] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/04/2021] [Accepted: 02/10/2022] [Indexed: 11/24/2022] Open
Abstract
Objective To report the clinical outcomes of a 25-gauge, beveled-tip, 10,000 cuts-per-minute (cpm) microincisional vitrectomy surgery (MIVS) system. Methods Prospective case series of eyes undergoing primary pars plana vitrectomy (PPV) for common vitreoretinal indications. Main outcome measures were: rate of achieving surgical objectives, operative times, number of surgical steps, use of ancillary instruments, corrected distance visual acuity (CDVA), and adverse events (AE). Results The surgical objectives were achieved in all eyes. Mean total operative time (TOT), core, shave and total vitrectomy times were 1891 ± 890, 204 ± 120, 330 ± 320, 534 ± 389 s, respectively. Mean number of surgical steps was 4.3 ± 1.5. Mean number of ancillary instruments used was 4.5 ± 1.9. Mean CDVA improved by 0.53 ± 0.56 logMAR units (P < 0.001) 3 months postoperatively. AE included elevated IOP (8%), hypotony (6%), and re-detachment (2%). Majority (82%) had no postoperative discomfort. The number of surgical steps demonstrated a positive correlation with TOT (p < 0.05), number of ancillary instruments used (p < 0.05), and postoperative Day 1 IOP (p < 0.05). The number of times ancillary instrumentation was used demonstrated a positive correlation with TOT (p < 0.05). Conclusion Beveled-tip, 10,000 cpm MIVS system effectively and safely performs common VR procedures of varying complexity and may reduce operative times and use of ancillary instrumentation. Supplementary Information The online version contains supplementary material available at 10.1186/s12886-022-02311-3.
Collapse
|
9
|
Seyyar SA, Saygılı O, Tıskaoğlu NS. Intraocular pressure outcomes after 23-G vitreoretinal surgery with two different transconjunctival sutureless sclerotomy techniques: vertical versus tunnel entry. Int Ophthalmol 2022; 42:1763-1769. [DOI: 10.1007/s10792-021-02172-7] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/28/2021] [Accepted: 12/18/2021] [Indexed: 10/19/2022]
|
10
|
Wu W, Cao W, Chen J, Cai Y, Dong B, Chu X. In Situ Liquid Crystal Gel as a Promising Strategy for Improving Ocular Administration of Dexamethasone: Preparation, Characterization, and Evaluation. AAPS PharmSciTech 2021; 23:36. [PMID: 34951001 DOI: 10.1208/s12249-021-02193-6] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/19/2021] [Accepted: 11/29/2021] [Indexed: 01/10/2023] Open
Abstract
The purpose of this study was to design an in situ liquid crystal gel (ISLG) as an ophthalmic drug delivery system for dexamethasone (DEX) to enhance its eye retention and ocular bioavailability. The in situ liquid crystal gels (ISLGs) were prepared using a phytantriol/PEG400/water (65:30:5, w/w) ternary system. Polarized light microscope (PLM), small-angle X-ray scattering (SAXS), and rheology analysis confirmed that the internal structure of the preparations was Pn3m cubic phase liquid crystal gels with pseudoplastic fluid properties. Meanwhile, in vitro release behavior of the preparations conforms to the Higuchi equation. Corneal penetration experiments showed that compared with DEX sodium phosphate eye drops, DEX-ISLGs(F2) produced a 5.45-fold increase in the Papp value, indicating a significant enhancement of corneal penetration. In addition, in vivo experiments have confirmed that the ISLGs have better biocompatibility and longer retention time in the cornea. Simultaneously, corneal hydration level, eye irritation experiments, and histological observations proved the safety of the preparations. Pharmacokinetic studies have shown that the ISLG could maintain the DEX concentration in aqueous humor for at least 12 h after administration, which significantly improves the bioavailability of the drug. Collectively, these results indicated that ISLG would be a potential drug carrier for the treatment of diabetic retinopathy (DR).
Collapse
|
11
|
Chen PL, Chen YT, Chen SN. Comparison of 27-gauge and 25-gauge vitrectomy in the management of tractional retinal detachment secondary to proliferative diabetic retinopathy. PLoS One 2021; 16:e0249139. [PMID: 33765074 PMCID: PMC7993849 DOI: 10.1371/journal.pone.0249139] [Citation(s) in RCA: 16] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/22/2020] [Accepted: 03/09/2021] [Indexed: 11/18/2022] Open
Abstract
OBJECTIVE To compare surgical outcomes between 27 and 25-gauge vitrectomy in proliferative diabetic retinopathy (PDR) with tractional retinal detachment (TRD). METHODS This retrospective study was conducted to compare the intraoperative status, operation time, use of instruments, endotamponade substance, wound suture number, and iatrogenic break, between 27 and 25-gauge vitrectomy in 43 eyes afflicted by PDR with TRD. The post-surgical results, best-corrected visual acuity, intraocular pressure, recurrent vitreous haemorrhage, and re-operation rate were regularly followed up for 6 months. RESULTS Patients in the 25 and the 27-gauge groups did not differ significantly in terms of pre-surgical conditions, such as age, gender, pre-existing glaucoma, best-corrected visual acuity (BCVA) and the severity of their TRD. The mean operation time was 56.7 minutes in the 27-gauge group and 63.7 minutes in the 25-gauge group (p = 0.94). There is significantly less use of micro forceps in the 27-gauge group (p = 0.004). No difference between micro scissors and chandelier usage were noted; neither was their difference in iatrogenic retinal breaks. Significantly fewer wound sutures were noted in the 27-gauge group (p < 0.001). The post-operative results revealed no significant difference in ocular hypertension, hypotony, BCVA improvement, recurrent vitreous haemorrhage and re-operation rate. CONCLUSIONS The 27-gauge vitrectomy system offers comparable surgical outcomes in PDR with TRD. The 27-gauge vitrectomy system is suitable for complicated retinal surgery.
Collapse
Affiliation(s)
- Po-Lin Chen
- Department of Ophthalmology, Changhua Christian Hospital, Changhua, Taiwan
| | - Yan-Ting Chen
- Department of Ophthalmology, Changhua Christian Hospital, Changhua, Taiwan
- Institute of Clinical Medicine, National Yang-Ming University, Taipei, Taiwan
- Department of Optometry, Central Taiwan University of Science and Technology, Taichung, Taiwan
| | - San-Ni Chen
- Department of Ophthalmology, Changhua Christian Hospital, Changhua, Taiwan
- College of Medicine, Chung-Shan Medical University, Taichung, Taiwan
- Department of Optometry, Da-Yeh University, Changhua, Taiwan
- * E-mail:
| |
Collapse
|
12
|
Liu Y, Wu N. Progress of Nanotechnology in Diabetic Retinopathy Treatment. Int J Nanomedicine 2021; 16:1391-1403. [PMID: 33658779 PMCID: PMC7917322 DOI: 10.2147/ijn.s294807] [Citation(s) in RCA: 54] [Impact Index Per Article: 13.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/27/2020] [Accepted: 02/05/2021] [Indexed: 12/16/2022] Open
Abstract
Diabetic retinopathy (DR) is a chronic diabetes complication that progressively manifests itself as blurred vision, eye floaters, distorted vision, and even partial or total loss of vision as a result of retinal detachment in severe cases. Clinically, patients who have undergone variations in the microcirculation of the ocular fundus are treated with laser photocoagulation to improve the circulation of retina; but for patients with macular edema, anti-vascular endothelial growth factor (anti-VEGF) drugs are generally injected to eliminate macular edema and improve vision. The worst cases are patients with fundus hemorrhage or proliferative vitreoretinopathy, for whom vitrectomy has been performed. At present, these clinical treatment methods have widely been used, providing satisfactory results. However, considering the low bioavailability and potential side effects of drugs and the inevitable risks in major surgery, DR prevention, and treatment as well as nerve tissue regeneration in the later stage have always been the focus of research. In recent years, nanotechnology has been increasingly applied in the medical field, leading to new ideas for DR treatment. This study aims to systematically review the research progress of nanotechnology in DR treatment.
Collapse
Affiliation(s)
- Yuxin Liu
- Student Affairs Department, Shengjing Hospital of China Medical University, Shenyang, 110004, People’s Republic of China
| | - Na Wu
- Department of Endocrinology, Shengjing Hospital of China Medical University, Shenyang, 110004, People’s Republic of China
- Clinical Skills Practice Teaching Center, Shengjing Hospital of China Medical University, Shenyang, 110004, People’s Republic of China
| |
Collapse
|
13
|
Brown GT, Pugazhendhi S, Beardsley RM, Karth JW, Karth PA, Hunter AA. 25 vs. 27-gauge micro-incision vitrectomy surgery for visually significant macular membranes and full-thickness macular holes: a retrospective study. Int J Retina Vitreous 2020; 6:56. [PMID: 33292716 PMCID: PMC7670804 DOI: 10.1186/s40942-020-00259-4] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/18/2020] [Accepted: 11/05/2020] [Indexed: 11/10/2022] Open
Abstract
BACKGROUND To evaluate visual and safety outcomes for 25-gauge (25G) and 27-gauge (27G) micro-incision vitrectomy platforms (MIVS) for the treatment of epiretinal membrane and full-thickness macular holes. METHODS Retrospective analysis of all patients who underwent internal limiting membrane (ILM) peel surgery from January 2017 through December 2018. 207 cases met the eligibility criteria for inclusion. Primary endpoint was post-operative Best-Corrected Distance Visual Acuity (BCVA) at 6 months. RESULTS For all patients combined, mean logMAR BCVA improved from 0.57 (± 0.40) to 0.37 (± 0.36) post-operatively (p < 0.001). For 25G ERMs, logMAR BCVA improved from 0.51 (± 0.28) to 0.30 (± 0.25) post-operatively (p < 0.001). For 27G ERMs, logMAR BCVA improved from 0.33 (± 0.28) to 0.28 (± 0.27) post- operatively (p = 0.15). For 25G FTMHs, logMAR BCVA improved from 0.87 (± 0.48) to 0.51 (± 0.44) post-operatively (p < 0.001). For 27G FTMHs, logMAR BCVA changed from 0.89 (± 0.47) to 0.96 (± 0.60). CONCLUSION Final visual outcomes improved for both 25G and 27G ERM groups and the 25G FTMH group. Both 25G and 27G were safe and well tolerated MIVS platforms for the treatment of ERM and FTMH.
Collapse
Affiliation(s)
- Gordon T Brown
- Oregon Eye Consultants LLC, 1550 Oak St, Suite 7, Eugene, OR, 97401, USA.
| | | | - Robert M Beardsley
- Oregon Eye Consultants LLC, 1550 Oak St, Suite 7, Eugene, OR, 97401, USA
| | - John W Karth
- Oregon Eye Consultants LLC, 1550 Oak St, Suite 7, Eugene, OR, 97401, USA
| | - Peter A Karth
- Oregon Eye Consultants LLC, 1550 Oak St, Suite 7, Eugene, OR, 97401, USA
| | - Allan A Hunter
- Oregon Eye Consultants LLC, 1550 Oak St, Suite 7, Eugene, OR, 97401, USA
| |
Collapse
|
14
|
Saleh OA, Alshamarti SA, Abu-Yaghi NE. Comparison of Characteristics and Clinical Outcomes in 27-Gauge versus 23-Gauge Vitrectomy Surgery. Clin Ophthalmol 2020; 14:1553-1558. [PMID: 32606569 PMCID: PMC7293406 DOI: 10.2147/opth.s255162] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/23/2020] [Accepted: 05/19/2020] [Indexed: 11/23/2022] Open
Abstract
Purpose To compare characteristics, clinical outcomes and complication profiles of a cohort of patients undergoing 27-gauge versus 23-gauge vitrectomy surgery at a tertiary medical center in the Middle East. Methods This is a retrospective comparative study of indication-matched patients undergoing 27-gauge versus 23-gauge pars plana vitrectomy for a set of predetermined diagnoses. Data including indications for surgery, clinical exams, visual outcomes, and complications were documented and analyzed. Results A total of 22 patients who had 27-gauge pars plana vitrectomy were compared with 44 patients who had 23-gauge surgery for matched indications by a single retina surgeon. Mean follow-up was 14 months after surgery. Indications included macular pucker, macular hole, and vitreous hemorrhage. Both the rate of hypotony at postoperative day 1 and the need for sclerotomy stitching at the end of surgery were significantly more frequent in 23-gauge compared to 27-gauge cases (25% in 23-gauge compared to 0% in 27-gauge (p=0.012) and 18% in the 23-gauge compared to 0% in the 27-gauge (p=0.045), respectively). The mean duration of surgery was similar among groups (35 mins in the 27-gauge group versus 39 mins in the 23-gauge group (p=0.116)), and all eyes achieved anatomic success. In the 27-gauge group, best-corrected visual acuity improved from a mean of 20/90 at baseline to a mean of 20/40 at 1 month (p=0.005) and in the 23-gauge group from a mean of 20/95 to 20/50 (p=0.001) with no statistical difference between the groups. Conclusion In this cohort of patients undergoing vitrectomy at a tertiary eye center, the rate of hypotony and the need for sclerotomy suturing were significantly less in the 27-gauge group versus the 23-gauge group. Surgical outcomes were similar in both study groups. The use of the novel 27-gauge instrument system is useful in selected vitreoretinal diseases and appears comparable to the widely used 23-gauge system.
Collapse
Affiliation(s)
- Omar A Saleh
- Department of Ophthalmology, Jordan University of Science and Technology, Irbid, Jordan
| | - Saif A Alshamarti
- Department of Ophthalmology, College of Medicine, University of Al-Qadisiyah, Diwanyah, Iraq
| | - Nakhleh E Abu-Yaghi
- Department of Special Surgery/Ophthalmology Division, School of Medicine, The University of Jordan, Amman, Jordan
| |
Collapse
|