1
|
Khaing E, Aroudaky A, Dircks D, Almerstani M, Alziadin N, Frankel S, Hollenberg B, Limsiri P, Schleifer W, Easley A, Tsai S, Anderson D, Windle J, Khan F, Haynatzki G, Peeraphatdit T, Goyal N, Dunbar Matos CL, Naksuk N. Representation of Women in Atrial Fibrillation Ablation Randomized Controlled Trials: Systematic Review. J Am Heart Assoc 2025; 14:e035181. [PMID: 39791402 PMCID: PMC12054437 DOI: 10.1161/jaha.124.035181] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/24/2024] [Accepted: 09/16/2024] [Indexed: 01/12/2025]
Abstract
BACKGROUND Sex inequality in randomized controlled trials (RCTs) related to cardiovascular disease has been observed. This study examined the proportion of women enrolled in atrial fibrillation (AF) ablation RCTs and the potential risks of underrepresentation of women. METHODS AND RESULTS We systematically searched PubMed and Embase for AF ablation RCTs published from 2015 to 2022. Participant characteristics were compared among trials with higher and lower proportions of women. Of 147 AF ablation RCTs (30,055 participants), only 10 trials had enrolled women ≥50% of the total participants. Additionally, 42 trials (28.57%) excluded pregnant/breastfeeding women; 6 (4.1%) excluded reproductive-age women without reliable birth control. The proportion of women in AF RCTs ranged from 9% to 71% (median 31.5%), whereas the median proportion of men was 67.7%. The rate of women included in the trials was stable from 2015 to 2022 (P=0.49). Study characteristics, including funding source, showed no correlation with the rate of inclusion of women. RCTs with a higher proportion of female participants enrolled older patients with AF, had a higher prevalence of hypertension but less persistent AF, and smaller left atrium size (P<0.05 for all). Biological sex was evaluated as a risk factor or in a subgroup analysis in 28 RCTs; 10.7% of these trials observed the implication of sex on their results. CONCLUSION Women were underrepresented in contemporary AF ablation RCTs. Additionally, women enrolled in AF RCTs were likely to have more comorbidities but less advanced AF, limiting the applicability of the results to women with AF.
Collapse
Affiliation(s)
- Eh Khaing
- University of Nebraska OmahaOmahaNEUSA
| | - Ahmad Aroudaky
- Division of Cardiovascular MedicineUniversity of Nebraska Medical CenterOmahaNEUSA
| | - Danielle Dircks
- College of Medicine, University of Nebraska Medical CenterOmahaNEUSA
| | - Muaaz Almerstani
- Division of Cardiovascular MedicineUniversity of Nebraska Medical CenterOmahaNEUSA
| | - Nmair Alziadin
- Hospital Corporation of America Healthcare/Tufts University School of Medicine: Portsmouth Regional Hospital Internal Medicine Residency ProgramPortsmouthNHUSA
| | - Samuel Frankel
- College of Medicine, University of Nebraska Medical CenterOmahaNEUSA
| | | | - Pattarawan Limsiri
- Department of Obstetrics and GynecologyFaculty of Medicine Siriraj Hospital, Mahidol UniversityBangkokThailand
| | - William Schleifer
- Division of Cardiovascular MedicineUniversity of Nebraska Medical CenterOmahaNEUSA
| | - Arthur Easley
- Division of Cardiovascular MedicineUniversity of Nebraska Medical CenterOmahaNEUSA
| | - Shane Tsai
- Division of Cardiovascular MedicineUniversity of Nebraska Medical CenterOmahaNEUSA
| | - Daniel Anderson
- Division of Cardiovascular MedicineUniversity of Nebraska Medical CenterOmahaNEUSA
| | - John Windle
- Division of Cardiovascular MedicineUniversity of Nebraska Medical CenterOmahaNEUSA
| | - Faris Khan
- Division of Cardiovascular MedicineUniversity of Nebraska Medical CenterOmahaNEUSA
| | - Gleb Haynatzki
- Department of BiostatisticsUniversity of Nebraska Medical CenterOmahaNEUSA
| | | | - Neha Goyal
- Division of Cardiovascular MedicineUniversity of Nebraska Medical CenterOmahaNEUSA
| | | | - Niyada Naksuk
- Division of Cardiovascular MedicineUniversity of Nebraska Medical CenterOmahaNEUSA
| |
Collapse
|
2
|
Osorio J, Miranda-Arboleda AF, Velasco A, Varley AL, Rajendra A, Morales GX, Hoyos C, Matos C, Thorne C, D'Souza B, Silverstein JR, Metzl MD, Hebsur S, Costea AI, Kang S, Sellers M, Singh D, Salam T, Nazari J, Ro AS, Mazer S, Moretta A, Oza SR, Magnano AR, Sackett M, Dukes J, Patel P, Goyal SK, Senn T, Newton D, Romero JE, Zei PC. Real-world data of radiofrequency catheter ablation in paroxysmal atrial fibrillation: Short- and long-term clinical outcomes from the prospective multicenter REAL-AF Registry. Heart Rhythm 2024; 21:2083-2091. [PMID: 38768839 DOI: 10.1016/j.hrthm.2024.04.090] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/11/2024] [Revised: 04/25/2024] [Accepted: 04/26/2024] [Indexed: 05/22/2024]
Abstract
BACKGROUND The safety and long-term efficacy of radiofrequency (RF) catheter ablation (CA) of paroxysmal atrial fibrillation (PAF) has been well established. Contemporary techniques to optimize ablation delivery, reduce fluoroscopy use, and improve clinical outcomes have been developed. OBJECTIVE The purpose of this study was to assess the contemporary real-world practice approach and short and long-term outcomes of RF CA for PAF through a prospective multicenter registry. METHODS Using the REAL-AF (Real-world Experience of Catheter Ablation for the Treatment of Symptomatic Paroxysmal and Persistent Atrial Fibrillation; ClincalTrials.gov Identifier: NCT04088071) Registry, patients undergoing RF CA to treat PAF across 42 high-volume institutions and 79 experienced operators were evaluated. The procedures were performed using zero or reduced fluoroscopy, contact force sensing catheters, wide area circumferential ablation, and ablation index as a guide with a target of 380-420 for posterior and 500-550 for anterior lesions. The primary efficacy outcome was freedom from all-atrial arrhythmia recurrence at 12 months. RESULTS A total of 2470 patients undergoing CA from January 2018 to December 2022 were included. Mean age was 65.2 ±11.14 years, and 44% were female. Most procedures were performed without fluoroscopy (71.5%), with average procedural and total RF times of 95.4 ± 41.7 minutes and 22.1±11.8 minutes, respectively. At 1-year follow-up, freedom from all-atrial arrhythmias was 81.6% with 89.7% of these patients off antiarrhythmic drugs. No significant difference was identified comparing pulmonary vein isolation vs pulmonary vein isolation plus ablation approaches. The complication rate was 1.9%. CONCLUSION Refinement of RF CA to treat PAF using contemporary tools, standardized protocols, and electrophysiology laboratory workflows resulted in excellent short- and long-term clinical outcomes.
Collapse
Affiliation(s)
- Jose Osorio
- HCA Electrophysiology, Mercy Hospital, Miami, Florida
| | | | - Alejandro Velasco
- University of Texas Health Sciences Center at San Antonio, San Antonio, Texas
| | | | - Anil Rajendra
- Arrhythmia Institute at Grandview, Birmingham, Alabama
| | | | | | - Carlos Matos
- Brigham and Women`s Hospital, Boston, Massachusetts
| | | | - Benjamin D'Souza
- University of Pennsylvania Perelman School of Medicine, Philadelphia, Pennsylvania
| | | | | | | | | | - Steven Kang
- Sutter Alta Bates Summit Medical Center, Oakland, California
| | | | | | - Tariq Salam
- Pulse Heart Institute/Multicare, Tacoma, Washington
| | | | | | - Sean Mazer
- New Mexico Heart Institute, Albuquerque, New Mexico
| | | | | | | | | | | | - Parin Patel
- Ascension Medical Group, Indianapolis, Indiana
| | | | | | | | | | - Paul C Zei
- Brigham and Women`s Hospital, Boston, Massachusetts.
| |
Collapse
|
3
|
Dzhinsov KR. Methods and techniques for increasing the safety and efficacy of pulmonary vein isolation in patients with atrial fibrillation. Folia Med (Plovdiv) 2023; 65:713-719. [PMID: 38351752 DOI: 10.3897/folmed.65.e103031] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/05/2023] [Accepted: 07/16/2023] [Indexed: 02/16/2024] Open
Abstract
The most common type of sustained arrhythmia is atrial fibrillation (AF). Pulmonary vein isolation (PVI) is the cornerstone of catheter ablation for atrial fibrillation, which has emerged as the primary therapeutic strategy for atrial fibrillation patients. Unfortunately, about one-third of patients experience recurrent atrial arrhythmias after the procedure.
Collapse
|
4
|
Schlögl S, Schlögl KS, Bengel P, Bergau L, Haarmann H, Rasenack E, Hasenfuss G, Zabel M. Impact of open-irrigated radiofrequency catheter with contact force measurement on the efficacy and safety of atrial fibrillation ablation: a single-center direct comparison. J Interv Card Electrophysiol 2022; 65:685-693. [PMID: 35907108 PMCID: PMC9726666 DOI: 10.1007/s10840-022-01316-8] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/22/2022] [Accepted: 07/20/2022] [Indexed: 12/14/2022]
Abstract
BACKGROUND In atrial fibrillation (AF) patients, catheter ablation of pulmonary veins (PVI) is the most effective therapeutic option to maintain sinus rhythm. To improve successful PVI, contact force-sensing (CF) catheters became routinely available. Previous studies did not clearly show superior clinical efficacy in comparison with non-CF catheters. METHODS We investigated consecutive patients, who underwent index PVI for AF at our hospital between 2012 and 2018. Three hundred and fifty-four patients were ablated without CF. After availability of CF catheters in 2016, 317 patients were ablated using CF. In case of crossover between the groups, follow-up was censored. The primary endpoint was any documented atrial tachycardia (AT) or atrial fibrillation > 30 s after a 3-month blanking period. Secondary endpoints were procedural characteristics and periprocedural complications. RESULTS There was no significant difference between the groups at baseline except hyperlipidemia. After 365 days of follow-up, 67% of patients in the CF group remained free from AF/AT recurrence compared to 59% in non-CF group (P = 0.038). In multivariable Cox regression analysis, non-CF ablation was an independent risk factor for AF recurrence besides age and persistent AF. Total fluoroscopy time (15 ± 7.6 vs. 28 ± 15.9 min) and total procedure time (114 ± 29.6 vs. 136 ± 38.5 min) were significantly lower for CF-guided PVI (P < 0.001). Complication rates did not differ between groups (P = 0.661). CONCLUSIONS In our study, the AT/AF recurrence rate and pulmonary vein reconnection rate is lower after CF PVI with a similar complication rate but lower total procedure time and total fluoroscopy time compared to non-CF PVI.
Collapse
Affiliation(s)
- Simon Schlögl
- grid.411984.10000 0001 0482 5331Department of Cardiology and Pneumology, Heart Center, University Medical Center, Robert-Koch-Str. 40, 37075 Göttingen, Germany ,grid.452396.f0000 0004 5937 5237DZHK (German Center for Cardiovascular Research), Partner Site Göttingen, Göttingen, Germany
| | - Klaudia Stella Schlögl
- grid.411984.10000 0001 0482 5331Department of Cardiology and Pneumology, Heart Center, University Medical Center, Robert-Koch-Str. 40, 37075 Göttingen, Germany
| | - Philipp Bengel
- grid.411984.10000 0001 0482 5331Department of Cardiology and Pneumology, Heart Center, University Medical Center, Robert-Koch-Str. 40, 37075 Göttingen, Germany ,grid.452396.f0000 0004 5937 5237DZHK (German Center for Cardiovascular Research), Partner Site Göttingen, Göttingen, Germany
| | - Leonard Bergau
- grid.411984.10000 0001 0482 5331Department of Cardiology and Pneumology, Heart Center, University Medical Center, Robert-Koch-Str. 40, 37075 Göttingen, Germany
| | - Helge Haarmann
- grid.411984.10000 0001 0482 5331Department of Cardiology and Pneumology, Heart Center, University Medical Center, Robert-Koch-Str. 40, 37075 Göttingen, Germany ,grid.452396.f0000 0004 5937 5237DZHK (German Center for Cardiovascular Research), Partner Site Göttingen, Göttingen, Germany
| | - Eva Rasenack
- grid.411984.10000 0001 0482 5331Department of Cardiology and Pneumology, Heart Center, University Medical Center, Robert-Koch-Str. 40, 37075 Göttingen, Germany
| | - Gerd Hasenfuss
- grid.411984.10000 0001 0482 5331Department of Cardiology and Pneumology, Heart Center, University Medical Center, Robert-Koch-Str. 40, 37075 Göttingen, Germany ,grid.452396.f0000 0004 5937 5237DZHK (German Center for Cardiovascular Research), Partner Site Göttingen, Göttingen, Germany
| | - Markus Zabel
- grid.411984.10000 0001 0482 5331Department of Cardiology and Pneumology, Heart Center, University Medical Center, Robert-Koch-Str. 40, 37075 Göttingen, Germany ,grid.452396.f0000 0004 5937 5237DZHK (German Center for Cardiovascular Research), Partner Site Göttingen, Göttingen, Germany
| |
Collapse
|
5
|
Varley AL, Kreidieh O, Godfrey BE, Whitmire C, Thorington S, D'Souza B, Kang S, Hebsur S, Ravindran BK, Zishiri E, Gidney B, Sellers MB, Singh D, Salam T, Metzl M, Ro A, Nazari J, Fisher WG, Costea A, Magnano A, Oza S, Morales G, Rajendra A, Silverstein J, Zei PC, Osorio J. A prospective multi-site registry of real-world experience of catheter ablation for treatment of symptomatic paroxysmal and persistent atrial fibrillation (Real-AF): design and objectives. J Interv Card Electrophysiol 2021; 62:487-494. [PMID: 34212280 PMCID: PMC8249214 DOI: 10.1007/s10840-021-01031-w] [Citation(s) in RCA: 9] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/01/2021] [Accepted: 06/24/2021] [Indexed: 12/16/2022]
Abstract
Purpose Catheter ablation has become a mainstay therapy for atrial fibrillation (AF) with rapid innovation over the past decade. Variability in ablation techniques may impact efficiency, safety, and efficacy; and the ideal strategy is unknown. Real-world evidence assessing the impact of procedural variations across multiple operators may provide insight into these questions. The Real-world Experience of Catheter Ablation for the Treatment of Symptomatic Paroxysmal (PAF) and Persistent (PsAF) Atrial Fibrillation registry (Real-AF) is a multicenter prospective registry that will enroll patients at high volume centers, including academic institutions and private practices, with operators performing ablations primarily with low fluoroscopy when possible. The study will also evaluate the contribution of advent in technologies and workflows to real-world clinical outcomes. Methods Patients presenting at participating centers are screened for enrollment. Data are collected at the time of procedure, 10–12 weeks, and 12 months post procedure and include patient and detailed procedural characteristics, with short and long-term outcomes. Arrhythmia recurrences are monitored through standard of care practice which includes continuous rhythm monitoring at 6 and 12 months, event monitors as needed for routine care or symptoms suggestive of recurrence, EKG performed at every visit, and interrogation of implanted device or ILR when applicable. Results Enrollment began in January 2018 with a single site. Additional sites began enrollment in October 2019. Through May 2021, 1,243 patients underwent 1,269 procedures at 13 institutions. Our goal is to enroll 4000 patients. Discussion Real-AF’s multiple data sources and detailed procedural information, emphasis on high volume operators, inclusion of low fluoroscopy operators, and use of rigorous standardized follow-up methodology allow systematic documentation of clinical outcomes associated with changes in ablation workflow and technologies over time. Timely data sharing may enable real-time quality improvements in patient care and delivery. Trial registration Clinicaltrials.gov: NCT04088071 (registration date: September 12, 2019) Supplementary Information The online version contains supplementary material available at 10.1007/s10840-021-01031-w.
Collapse
Affiliation(s)
- Allyson L Varley
- Heart Rhythm Clinical and Research Solutions, LLC, AL, Birmingham, USA.
- Birmingham VA Health System, AL, Birmingham, USA.
| | - Omar Kreidieh
- Cardiac Arrhythmia Service, Brigham and Women's Hospital, MA, Boston, USA
| | - Brigham E Godfrey
- Heart Rhythm Clinical and Research Solutions, LLC, AL, Birmingham, USA
- Arrhythmia Institute at Grandview Medical Center, AL, Birmingham, USA
| | - Carolyn Whitmire
- Grandview Medical Group Research, Grandview Medical Center, AL, Birmingham, USA
| | - Susan Thorington
- Grandview Medical Group Research, Grandview Medical Center, AL, Birmingham, USA
| | - Benjamin D'Souza
- Department of Medicine, Penn Presbyterian Medical Center, University of Pennsylvania, PA, Philadelphia, USA
| | | | | | | | | | - Brett Gidney
- Santa Barbara Cottage Hospital, CA, Santa Barbara, USA
| | | | - David Singh
- Center for Heart Rhythm Disorders, The Queen's Medical Center, HI, Honolulu, USA
| | - Tariq Salam
- PulseHeart Institute, Multicare Health System, WA, Tacoma, USA
| | - Mark Metzl
- NorthShore University HealthSystem, IL, Evanston, USA
| | - Alex Ro
- NorthShore University HealthSystem, IL, Evanston, USA
| | - Jose Nazari
- NorthShore University HealthSystem, IL, Evanston, USA
| | | | - Alexandru Costea
- Division of Cardiovascular Health and Disease, University of Cincinnati, OH, Cincinnati, USA
| | - Anthony Magnano
- Department of Cardiology, Ascension St. Vincent's Health System, FL, Jacksonville, USA
| | - Saumil Oza
- Department of Cardiology, Ascension St. Vincent's Health System, FL, Jacksonville, USA
| | - Gustavo Morales
- Arrhythmia Institute at Grandview Medical Center, AL, Birmingham, USA
| | - Anil Rajendra
- Arrhythmia Institute at Grandview Medical Center, AL, Birmingham, USA
| | | | - Paul C Zei
- Cardiac Arrhythmia Service, Brigham and Women's Hospital, MA, Boston, USA
| | - Jose Osorio
- Heart Rhythm Clinical and Research Solutions, LLC, AL, Birmingham, USA
- Arrhythmia Institute at Grandview Medical Center, AL, Birmingham, USA
| |
Collapse
|
6
|
Bourier F, Popa M, Kottmaier M, Maurer S, Bahlke F, Telishevska M, Lengauer S, Koch-Büttner K, Kornmayer M, Risse E, Brkic A, Reents T, Hessling G, Deisenhofer I. RF electrode-tissue coverage significantly influences steam pop incidence and lesion size. J Cardiovasc Electrophysiol 2021; 32:1594-1599. [PMID: 33928696 DOI: 10.1111/jce.15063] [Citation(s) in RCA: 22] [Impact Index Per Article: 5.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/06/2021] [Revised: 03/04/2021] [Accepted: 03/16/2021] [Indexed: 01/18/2023]
Abstract
BACKGROUND Steam pops are a rare complication associated with radiofrequency (RF) ablation and are hard to predict. The aim of this study was to assess the influence of coverage between the RF ablation electrode and cardiac tissue on steam pop incidence and lesion size. METHODS AND RESULTS An ex vivo model using porcine cardiac preparations and contact force sensing catheters was designed to perform RF ablations at different coverage levels between the RF electrode and cardiac tissue. During coverage level I, only the distal part of the ablation electrode was in contact with tissue. During coverage level II half of the ablation electrode, and during coverage level III the entire ablation electrode was embedded in tissue. RF applications (n = 60) at different coverage levels I-III were systematically performed using the same standardized ablation protocol. Ablations during coverage level III resulted in a significantly higher rate of steam pops (100%) when compared to ablations during coverage level II (10%) and coverage level I (0%), log rank p < .001. Coverage level I ablations resulted in significantly smaller lesion depths, diameters, and impedance drops when compared to higher coverage level ablations, p < .001. In the controlled ex vivo model, there was no difference in applied contact force or energy between different coverage levels. CONCLUSIONS The level of coverage between RF electrode, cardiac tissue, and the surrounding fluid significantly influenced the incidence of steam pops in an ex vivo setup. Larger coverage between RF electrode and tissue resulted in significantly larger lesion dimensions.
Collapse
Affiliation(s)
- Felix Bourier
- Department of Electrophysiology, German Heart Center Munich, Technical University Munich, Munich, Germany
| | - Miruna Popa
- Department of Electrophysiology, German Heart Center Munich, Technical University Munich, Munich, Germany
| | - Marc Kottmaier
- Department of Electrophysiology, German Heart Center Munich, Technical University Munich, Munich, Germany
| | - Susanne Maurer
- Department of Electrophysiology, German Heart Center Munich, Technical University Munich, Munich, Germany
| | - Fabian Bahlke
- Department of Electrophysiology, German Heart Center Munich, Technical University Munich, Munich, Germany
| | - Marta Telishevska
- Department of Electrophysiology, German Heart Center Munich, Technical University Munich, Munich, Germany
| | - Sarah Lengauer
- Department of Electrophysiology, German Heart Center Munich, Technical University Munich, Munich, Germany
| | - Katharina Koch-Büttner
- Department of Electrophysiology, German Heart Center Munich, Technical University Munich, Munich, Germany
| | - Marielouise Kornmayer
- Department of Electrophysiology, German Heart Center Munich, Technical University Munich, Munich, Germany
| | - Elena Risse
- Department of Electrophysiology, German Heart Center Munich, Technical University Munich, Munich, Germany
| | - Amir Brkic
- Department of Electrophysiology, German Heart Center Munich, Technical University Munich, Munich, Germany
| | - Tilko Reents
- Department of Electrophysiology, German Heart Center Munich, Technical University Munich, Munich, Germany
| | - Gabriele Hessling
- Department of Electrophysiology, German Heart Center Munich, Technical University Munich, Munich, Germany
| | - Isabel Deisenhofer
- Department of Electrophysiology, German Heart Center Munich, Technical University Munich, Munich, Germany
| |
Collapse
|
7
|
Rattanakosit T, Franke K, Munawar DA, Page AJ, Boyd MA, Lau DH, Mahajan R. Role of Indices Incorporating Power, Force and Time in AF Ablation: A Systematic Review of Literature. Heart Lung Circ 2021; 30:1379-1388. [PMID: 33958295 DOI: 10.1016/j.hlc.2021.04.007] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/08/2021] [Revised: 04/01/2021] [Accepted: 04/05/2021] [Indexed: 12/20/2022]
Abstract
INTRODUCTION Successful pulmonary vein isolation (PVI) for atrial fibrillation (AF) depends on the formation of durable transmural lesions. Recently, novel indices have emerged to guide lesion delivery. The aim of the systematic review of literature was to determine AF recurrence following ablation guided by indices incorporating force, power and time, and compare acute procedural outcomes and 12-month AF recurrence with ablation guided by contact force (CF) guided only. METHODS PubMed, EMBASE, and Web of Science Core Collection databases were searched on 27 January 2020 using the keywords; catheter ablation, ablation index (AI), lesion size index (LSI), contact force, atrial fibrillation. RESULTS After exclusions, seven studies were included in the analysis. AI-guided catheter ablation was associated with a 91% (n=5, 0.91 95% CI; 0.88-0.93) and 80% (n=5, 0.80, 95% CI; 0.77-0.84) freedom from AF at 12 months with and without the use of anti-arhythmic drugs respectively. As compared to CF guided ablation, AI-guided catheter ablation was associated with a 49% increase in successful first pass isolation (n=3; RR: 1.49, 95% CI; 1.38, 1.61), a 50% decrease in number of acute reconnections (n=4; RR: 0.50, 95% CI; 0.39-0.65) and a 22% (n=4, RR: 1.22, 95% CI; 1.10-1.35) increase in AF freedom without anti-arrhythmic drugs at 12 months. CONCLUSIONS Radiofrequency ablation guided by AI was associated with higher successful first pass isolation and lower rates of acute reconnection which translates to greater freedom from AF at 12 months [CRD42019131469].
Collapse
Affiliation(s)
- Thirakan Rattanakosit
- Faculty of Health and Medical Sciences, The University of Adelaide, Adelaide, SA, Australia; South Australian Health and Medical Research Institute, Adelaide, SA, Australia
| | - Kyle Franke
- Faculty of Health and Medical Sciences, The University of Adelaide, Adelaide, SA, Australia
| | - Dian Andina Munawar
- Faculty of Health and Medical Sciences, The University of Adelaide, Adelaide, SA, Australia; South Australian Health and Medical Research Institute, Adelaide, SA, Australia; Lyell McEwin Hospital, Adelaide, SA, Australia
| | - Amanda J Page
- Faculty of Health and Medical Sciences, The University of Adelaide, Adelaide, SA, Australia; South Australian Health and Medical Research Institute, Adelaide, SA, Australia
| | - Mark A Boyd
- Faculty of Health and Medical Sciences, The University of Adelaide, Adelaide, SA, Australia; Lyell McEwin Hospital, Adelaide, SA, Australia
| | - Dennis H Lau
- Faculty of Health and Medical Sciences, The University of Adelaide, Adelaide, SA, Australia; South Australian Health and Medical Research Institute, Adelaide, SA, Australia; Royal Adelaide Hospital, Adelaide, SA, Australia
| | - Rajiv Mahajan
- Faculty of Health and Medical Sciences, The University of Adelaide, Adelaide, SA, Australia; South Australian Health and Medical Research Institute, Adelaide, SA, Australia; Lyell McEwin Hospital, Adelaide, SA, Australia.
| |
Collapse
|
8
|
Virk SA, Ariyaratnam J, Bennett RG, Kumar S. Updated systematic review and meta-analysis of the impact of contact force sensing on the safety and efficacy of atrial fibrillation ablation: discrepancy between observational studies and randomized control trial data. Europace 2020; 21:239-249. [PMID: 30544134 DOI: 10.1093/europace/euy266] [Citation(s) in RCA: 24] [Impact Index Per Article: 4.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/30/2018] [Accepted: 10/11/2018] [Indexed: 12/19/2022] Open
Abstract
Aims Despite widespread adoption of contact force (CF) sensing technology in atrial fibrillation (AF) ablation, randomized data suggests lack of improvement in clinical outcomes. We aimed to assess the safety and efficacy of CF-guided vs. non CF-guided AF ablation. Methods and results Electronic databases were searched for randomized controlled trials (RCTs) and controlled observational studies (OS) comparing outcomes of AF ablation performed with vs. without CF guidance. The primary efficacy endpoint was freedom from AF at follow-up. The primary safety endpoint was major peri-procedural complications. Secondary endpoints included procedural, fluoroscopy, and ablation duration. Subgroup analyses were performed by AF type and study design. Nine RCTs (n = 903) and 26 OS (n = 8919) were included. Overall, CF guidance was associated with improved freedom from AF [relative risk (RR) 1.10; 95% confidence interval (CI) 1.02-1.18], and reduced total procedure duration [mean difference (MD) 15.33 min; 95% CI 6.98-23.68], ablation duration (MD 3.07 min; 95% CI 0.29-5.84), and fluoroscopy duration (MD 5.72 min; 95% CI 2.51-8.92). When restricted to RCTs however, CF guidance neither improved freedom from AF (RR 1.03; 95% CI 0.95-1.11), independent of AF type, nor did it reduce procedural, fluoroscopy, or ablation duration. Contact force guidance did not reduce the incidence of major peri-procedural complications (RR 0.89; 95% CI 0.64-1.24). Conclusion Meta-analysis of randomized data demonstrated that CF guidance does not improve the safety or efficacy of AF ablation, despite initial observational data showing dramatic improvement. Rigorous evaluation in randomized trials is needed before widespread adoption of new technologies.
Collapse
Affiliation(s)
- Sohaib A Virk
- Department of Cardiology, Westmead Hospital, Sydney, Australia
| | | | | | - Saurabh Kumar
- Department of Cardiology, Westmead Hospital, Sydney, Australia.,Department of Cardiology, Westmead Hospital, Westmead Applied Research Centre, University of Sydney, Hawkesbury Road, Westmead, Sydney, NSW 2145, Australia
| |
Collapse
|
9
|
Real-world safety of catheter ablation for atrial fibrillation with contact force or cryoballoon ablation. J Interv Card Electrophysiol 2020; 60:445-452. [PMID: 32390061 PMCID: PMC8134302 DOI: 10.1007/s10840-020-00734-w] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/27/2019] [Accepted: 03/23/2020] [Indexed: 11/12/2022]
Abstract
Purpose Real-world data can help medical administrators, physicians, and payers make evidence-based decisions regarding treatment choices. The objective of this study was to compare real-world safety outcomes with the latest catheter technologies used for the treatment of atrial fibrillation (AF). Methods The Vizient Health Systems database, a large US hospital database, was used to compare acute complications in AF ablation with the contact force sensing THERMOCOOL SMARTTOUCH® Catheter or the THERMOCOOL SMARTTOUCH® SF Catheter (ST) versus the second-generation Arctic Front Advance™ Cryoablation Catheter (CB2) between September 2015 and June 2017. The primary outcome was a composite safety endpoint of acute ablation-related complications defined via ICD-10 diagnosis and procedure codes, including tamponade and other pericardial events, respiratory complications, stroke, cerebral or pre-cerebral occlusion/stenosis without infarction, vascular access complications, hemorrhage, phrenic nerve injury, myocardial infarction, and pulmonary embolism. Results In total, 1473 ablations met all inclusion criteria (407 ST, 1066 CB2). Ablations for paroxysmal AF (PAF) had a lower complication rate than ablations for persistent AF (PsAF) (6.1% vs. 7.3%), as did ablations with ST compared with CB2 within each AF type (PAF 6.0% vs. 6.1%, PsAF 6.3% vs. 7.8%). Neither ablation catheter nor AF type was statistically significant after controlling for site volume, patient age, and comorbid conditions (ST vs. CB2: OR 0.86, p = 0.5544; PsAF vs. PAF: OR 1.08, p = 0.7376). Conclusion Acute ablation-related complication rates were low and were not significantly associated with catheter technology. Increased risk of complication was attributable to low-volume sites and baseline patient characteristics.
Collapse
|
10
|
Virk SA, Bennett RG, Trivic I, Campbell T, Kumar S. Contact Force and Ablation Index. Card Electrophysiol Clin 2020; 11:473-479. [PMID: 31400871 DOI: 10.1016/j.ccep.2019.05.007] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/19/2023]
Abstract
Radiofrequency ablation of arrhythmias depends on durable lesion formation. Catheter tip-tissue contact force (CF) is a key determinant of lesion quality; excessive CF is associated with major complications, whereas insufficient CF increases the risk of electrical reconnection and arrhythmia recurrence. In recent years, CF-sensing catheters have emerged with the ability to directly measure CF and provide operators with real-time feedback. CF-guided ablation has been associated with improved outcomes in observational studies. However, randomized controlled trials have not shown any reduction in procedural durations, fluoroscopy exposure, incidence of major complications, or long-term arrhythmia recurrence with use of CF-sensing catheters.
Collapse
Affiliation(s)
- Sohaib A Virk
- Department of Cardiology, Westmead Hospital, Westmead Applied Research Centre, University of Sydney, Sydney, Australia
| | | | - Ivana Trivic
- Department of Cardiology, Westmead Hospital, Westmead Applied Research Centre, University of Sydney, Sydney, Australia
| | - Timothy Campbell
- Department of Cardiology, Westmead Hospital, Westmead Applied Research Centre, University of Sydney, Sydney, Australia
| | - Saurabh Kumar
- Department of Cardiology, Westmead Hospital, Westmead Applied Research Centre, University of Sydney, Sydney, Australia.
| |
Collapse
|
11
|
So-Ryoung L, Hyoung-Seob P, Eue-Keun C, Soonil K, Youngjin C, Il-Young O, Seil O, Seongwook H. Contact Force-Guided Ablation Reduced Poor Contact Segments and Improved Acute Reconnection in Patients with Atrial Fibrillation. J Atr Fibrillation 2020; 12:2185. [PMID: 32435352 DOI: 10.4022/jafib.2185] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/31/2019] [Revised: 07/02/2019] [Accepted: 12/26/2019] [Indexed: 12/13/2022]
Abstract
Background There is a paucity of information regarding whether contact force (CF)-guided ablation improves the outcomes of pulmonary vein isolation (PVI) in patients with atrial fibrillation (AF) by achieving more optimal contact. We sought to assess whether real time CF-guided ablation has an impact on ablation parameters and acute pulmonary vein reconnection (PVR). Methods Left or right PVs were randomized to either CF-guided or blinded groups, and the order of CF blindness: CF-guided left PV/CF-blinded right PV, CF-blinded left PV/CF-guided right PV, CF-guided right PV/CF-blinded left PV, and CF-blinded right PV/CF-guided left PV groups. We compared CF parameters and acute PVR between segments ablated by CF-guided and CF-blinded strategies. Results Sixty patients with drug refractory symptomatic AF were included (paroxysmal AF 73%). CF-guided segments did not show significant differences in CF parameters compared to CF-blinded segments. However, CF-guided segments showed fewer segments with mean CF value <5 g than CF-blinded segments (4.3% vs. 12.4%, p<0.001). Forty-two patients showed acute PVR in 92 segments (8.5%). CF-guided PV segments showed lower acute PVR rate than CF-blinded segments (5.9% vs. 11.1%, p=0.011). Conclusions CF-guided ablation could reduce acute PVR after PVI by decreasing the number of segments with poor contact rather than increasing the mean CF during ablation. Better contact guided by CF information might help in improving the results of PVI. Further investigation will be needed to identify the association between the difference in acute reconnection and the long-term outcomes.
Collapse
Affiliation(s)
- Lee So-Ryoung
- Department of Internal Medicine, Seoul National University Hospital, Seoul, Republic of Korea.,the first two authors equally contributed
| | - Park Hyoung-Seob
- Division of Cardiology, Department of Internal Medicine, Keimyung University, Dongsan Medical Center, Daegu, Republic of Korea.,the first two authors equally contributed
| | - Choi Eue-Keun
- Department of Internal Medicine, Seoul National University Hospital, Seoul, Republic of Korea
| | - Kwon Soonil
- Department of Internal Medicine, Seoul National University Hospital, Seoul, Republic of Korea
| | - Cho Youngjin
- Department of Internal Medicine, Cardiovascular Center, Seoul National University Bundang Hospital, Seongnam, Republic of Korea
| | - Oh Il-Young
- Department of Internal Medicine, Cardiovascular Center, Seoul National University Bundang Hospital, Seongnam, Republic of Korea
| | - Oh Seil
- Department of Internal Medicine, Seoul National University Hospital, Seoul, Republic of Korea
| | - Han Seongwook
- Division of Cardiology, Department of Internal Medicine, Keimyung University, Dongsan Medical Center, Daegu, Republic of Korea
| |
Collapse
|
12
|
Ariyarathna N, Kumar S, Thomas SP, Stevenson WG, Michaud GF. Role of Contact Force Sensing in Catheter Ablation of Cardiac Arrhythmias: Evolution or History Repeating Itself? JACC Clin Electrophysiol 2019; 4:707-723. [PMID: 29929663 DOI: 10.1016/j.jacep.2018.03.014] [Citation(s) in RCA: 75] [Impact Index Per Article: 12.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/23/2017] [Revised: 03/12/2018] [Accepted: 03/22/2018] [Indexed: 12/28/2022]
Abstract
Adequate catheter-tissue contact facilitates efficient heat energy transfer to target tissue. Tissue contact is thus critical to achieving lesion transmurality and success of radiofrequency (RF) ablation procedures, a fact recognized more than 2 decades ago. The availability of real-time contact force (CF)-sensing catheters has reinvigorated the field of ablation biophysics and optimized lesion formation. The ability to measure and display CF came with the promise of dramatic improvement in safety and efficacy; however, CF quality was noted to have just as important an influence on lesion formation as absolute CF quantity. Multiple other factors have emerged as key elements influencing effective lesion formation, including catheter stability, lesion contiguity and continuity, lesion density, contact homogeneity across a line of ablation, spatiotemporal dynamics of contact governed by cardiac and respiratory motion, contact directionality, and anatomic wall thickness, in addition to traditional ablation indices of power and RF duration. There is greater appreciation of surrogate markers as a guide to lesion formation, such as impedance fall, loss of pace capture, and change in unipolar electrogram morphology. In contrast, other surrogates such as tactile feedback, catheter motion, and electrogram amplitude are notably poor predictors of actual contact and lesion formation. This review aims to contextualize the role of CF sensing in lesion formation with respect of the fundamental principles of biophysics of RF ablation and summarize the state-of-the-art evidence behind the role of CF in optimizing lesion formation.
Collapse
Affiliation(s)
- Nilshan Ariyarathna
- Cardiology Department, The Canberra Hospital, Canberra, Australian Capital Territory, Australia
| | - Saurabh Kumar
- Department of Cardiology, Westmead Hospital, Westmead Applied Research Centre, University of Sydney, New South Wales, Australia
| | - Stuart P Thomas
- Department of Cardiology, Westmead Hospital, Westmead Applied Research Centre, University of Sydney, New South Wales, Australia
| | - William G Stevenson
- Arrhythmia and Electrophysiology Program, Department of Medicine, Vanderbilt University Medical Center, Nashville, Tennessee
| | - Gregory F Michaud
- Arrhythmia and Electrophysiology Program, Department of Medicine, Vanderbilt University Medical Center, Nashville, Tennessee.
| |
Collapse
|
13
|
Chinitz LA, Melby DP, Marchlinski FE, Delaughter C, Fishel RS, Monir G, Patel AM, Gibson DN, Athill CA, Ming Boo L, Stagg R, Natale A. Safety and efficiency of porous-tip contact-force catheter for drug-refractory symptomatic paroxysmal atrial fibrillation ablation: results from the SMART SF trial. Europace 2019; 20:f392-f400. [PMID: 29016769 DOI: 10.1093/europace/eux264] [Citation(s) in RCA: 36] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/06/2017] [Accepted: 07/18/2017] [Indexed: 01/02/2023] Open
Abstract
Aims THERMOCOOL SMARTTOUCH® SF Catheter is a new contact-force (CF)-sensing catheter with 56-hole porous tip designed for improved cooling and reduced fluid delivery compared with a standard 6-hole open-irrigated catheter. The SMART SF study examined the periprocedural safety, acute effectiveness, and procedural efficiency of the catheter for drug-refractory symptomatic paroxysmal atrial fibrillation (PAF) ablation. Methods and results The prospective, open-label, non-randomized SMART-SF was conducted at 17 US sites. Circumferential pulmonary vein (PV) isolation was performed with confirmation of entrance block in all PVs. Stable ablation sites were identified using CARTO VISITAG™ Module. Primary adverse events (AEs; ≤1 week of index procedure), periprocedural AEs within 30 days of ablation procedure, acute effectiveness (confirmation of entrance block for targeted PVs), CF, and procedural parameters were assessed. Overall, 165 patients were enrolled (mean age, 62.7 years; male, 57.9%; white, 97%; left ventricular ejection fraction, 60.1 ± 7%; left atrium diameter, 38.8 ± 6 mm); 159 underwent radiofrequency ablation and comprised the safety cohort. Primary safety performance criteria were met: primary AE rate was 2.5% (4/159; cardiac tamponade [n = 2], thrombo-embolism [n = 1], transient ischaemic attack [n = 1]). All primary AEs resolved/improved within the 1-month follow-up period. Acute procedural effectiveness was attained in 96.2% (95% confidence interval: 92.0-98.6%) of patients. Procedure time, fluoroscopy time, and fluid delivered were observed in comparison to predecessor catheters. Conclusion In the SMART-SF trial, the predetermined safety performance goal was met, demonstrating the safety and acute effectiveness of the THERMOCOOL SMARTTOUCH® SF Catheter for PAF ablation.
Collapse
Affiliation(s)
- Larry A Chinitz
- NYU Langone Medical Center, New York University, 550 First Avenue, New York, NY, USA
| | | | | | | | | | - George Monir
- Florida Hospital Cardiovascular Institute, Orlando, FL, USA
| | | | | | | | - Lee Ming Boo
- Biosense Webster Inc., Diamond Bar, California, CA, USA
| | - Robert Stagg
- Biosense Webster Inc., Diamond Bar, California, CA, USA
| | - Andrea Natale
- Texas Cardiac Arrhythmia Research Foundation, Austin, TX, USA
| |
Collapse
|
14
|
Macle L, Frame D, Gache LM, Monir G, Pollak SJ, Boo LM. Atrial fibrillation ablation with a spring sensor-irrigated contact force-sensing catheter compared with other ablation catheters: systematic literature review and meta-analysis. BMJ Open 2019; 9:e023775. [PMID: 31189669 PMCID: PMC6575819 DOI: 10.1136/bmjopen-2018-023775] [Citation(s) in RCA: 26] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/13/2022] Open
Abstract
OBJECTIVES The objective of our review was to systematically assess available evidence on the effectiveness, safety and efficiency of a spring sensor-irrigated contact force (CF) catheter (THERMOCOOL SMARTTOUCH Catheter (ST)) for percutaneous ablation of paroxysmal or persistent atrial fibrillation (AF), compared with other ablation catheters, or with the ST with the operator blinded to CF data. DESIGN Systematic literature review and meta-analysis. BACKGROUND Emerging evidence suggests improved clinical outcomes of AF ablation using CF-sensing catheters; however, reviews to date have included data from multiple, distinct CF technologies. METHODS We conducted a systematic review and meta-analysis of published studies comparing the use of ST versus other ablation catheters for the treatment of AF. A comprehensive search of electronic and manual sources was conducted. The primary endpoint was freedom from recurrent atrial tachyarrhythmia (AT) at 12 months. Procedural and safety data were also analysed. RESULTS Thirty-four studies enrolling 5004 patients were eligible. The use of ST was associated with increased odds of freedom from AT at 12 months (71.0%vs60.8%; OR 1.454, 95% CI 1.12 to 1.88, p=0.004) over the comparator group, and the effect size was most evident in paroxysmal AF patients (75.6%vs64.7%; OR 1.560, 95% CI 1.09 to 2.24, p=0.015). Procedure and fluoroscopy times were shorter with ST (p=0.05 and p<0.01, respectively, vs comparator groups). The reduction in procedure time is estimated at 15.5 min (9.0%), and fluoroscopy time 4.8 min (18.7%). Complication rates, including cardiac tamponade, did not differ between groups. CONCLUSIONS Compared with the use of other catheters, AF ablation using the CF-sensing ST catheter for AF is associated with improved success rates, shorter procedure and fluoroscopy times and similar safety profile.
Collapse
Affiliation(s)
- Laurent Macle
- Department of Medicine, Institut De Cardiologie de Montreal, Montreal, Quebec, Canada
- Department of Medicine, Université de Montréal, Montreal, Quebec, Canada
| | - Diana Frame
- Real World Evidence (RWE), CTI Clinical Trial and Consulting Services Inc., Covington, Kentucky, USA
| | - Larry M Gache
- Real World Evidence (RWE), CTI Clinical Trial and Consulting Services Inc., Covington, Kentucky, USA
| | - George Monir
- Cardiology, Arrhythmia and Ablation Center, Florida Hospital, Orlando, Florida, USA
| | - Scott J Pollak
- Cardiology, Arrhythmia and Ablation Center, Florida Hospital, Orlando, Florida, USA
| | - Lee Ming Boo
- Clinical Research, Biosense Webster, Inc., Irvine, California, USA
| |
Collapse
|
15
|
Nakamura K, Naito S, Sasaki T, Take Y, Minami K, Kitagawa Y, Motoda H, Inoue M, Otsuka Y, Niijima K, Yamashita E, Sugai Y, Kumagai K, Koyama K, Funabashi N, Oshima S. Uninterrupted vs. interrupted periprocedural direct oral anticoagulants for catheter ablation of atrial fibrillation: a prospective randomized single-centre study on post-ablation thrombo-embolic and haemorrhagic events. Europace 2018; 21:259-267. [DOI: 10.1093/europace/euy148] [Citation(s) in RCA: 43] [Impact Index Per Article: 6.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/02/2018] [Accepted: 05/31/2018] [Indexed: 02/01/2023] Open
Affiliation(s)
- Kohki Nakamura
- Division of Cardiology, Gunma Prefectural Cardiovascular Center, 3-12 Kameizumi-machi, Maebashi City, Gunma, Japan
| | - Shigeto Naito
- Division of Cardiology, Gunma Prefectural Cardiovascular Center, 3-12 Kameizumi-machi, Maebashi City, Gunma, Japan
| | - Takehito Sasaki
- Division of Cardiology, Gunma Prefectural Cardiovascular Center, 3-12 Kameizumi-machi, Maebashi City, Gunma, Japan
| | - Yutaka Take
- Division of Cardiology, Gunma Prefectural Cardiovascular Center, 3-12 Kameizumi-machi, Maebashi City, Gunma, Japan
| | - Kentaro Minami
- Division of Cardiology, Gunma Prefectural Cardiovascular Center, 3-12 Kameizumi-machi, Maebashi City, Gunma, Japan
| | - Yoshiyuki Kitagawa
- Division of Cardiology, Gunma Prefectural Cardiovascular Center, 3-12 Kameizumi-machi, Maebashi City, Gunma, Japan
| | - Hiroyuki Motoda
- Division of Cardiology, Gunma Prefectural Cardiovascular Center, 3-12 Kameizumi-machi, Maebashi City, Gunma, Japan
| | - Mitsuho Inoue
- Division of Cardiology, Gunma Prefectural Cardiovascular Center, 3-12 Kameizumi-machi, Maebashi City, Gunma, Japan
| | - Yoshimitsu Otsuka
- Division of Cardiology, Gunma Prefectural Cardiovascular Center, 3-12 Kameizumi-machi, Maebashi City, Gunma, Japan
| | - Katsura Niijima
- Division of Cardiology, Gunma Prefectural Cardiovascular Center, 3-12 Kameizumi-machi, Maebashi City, Gunma, Japan
| | - Eiji Yamashita
- Division of Cardiology, Gunma Prefectural Cardiovascular Center, 3-12 Kameizumi-machi, Maebashi City, Gunma, Japan
| | - Yoshinao Sugai
- Division of Cardiology, Gunma Prefectural Cardiovascular Center, 3-12 Kameizumi-machi, Maebashi City, Gunma, Japan
| | - Koji Kumagai
- Division of Cardiology, Gunma Prefectural Cardiovascular Center, 3-12 Kameizumi-machi, Maebashi City, Gunma, Japan
| | - Keiko Koyama
- Division of Radiology, Gunma Prefectural Cardiovascular Center, 3-12 Kameizumi-machi, Maebashi City, Gunma, Japan
| | - Nobusada Funabashi
- Department of Cardiovascular Science and Medicine, Chiba University Graduate School of Medicine, 1-8-1 Inohana, Chuo-ku, Chiba City, Chiba, Japan
| | - Shigeru Oshima
- Division of Cardiology, Gunma Prefectural Cardiovascular Center, 3-12 Kameizumi-machi, Maebashi City, Gunma, Japan
| |
Collapse
|
16
|
Steinberg JS, Altman RK. Should the force be with us? Heart Rhythm 2018; 15:209-210. [DOI: 10.1016/j.hrthm.2017.10.040] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/16/2017] [Indexed: 11/26/2022]
|
17
|
Hussein A, Das M, Chaturvedi V, Asfour IK, Daryanani N, Morgan M, Ronayne C, Shaw M, Snowdon R, Gupta D. Prospective use of Ablation Index targets improves clinical outcomes following ablation for atrial fibrillation. J Cardiovasc Electrophysiol 2017. [PMID: 28639728 DOI: 10.1111/jce.13281] [Citation(s) in RCA: 123] [Impact Index Per Article: 15.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/11/2022]
Abstract
AIMS Late recovery of ablated tissue leading to reconnection of pulmonary veins remains common following radiofrequency catheter ablation for AF. Ablation Index (AI), a novel ablation quality marker, incorporates contact force (CF), time, and power in a weighted formula. We hypothesized that prospective use of our previously published derived AI targets would result in better outcomes when compared to CF-guided ablation. METHODS Eighty-nine consecutive drug-refractory AF patients (49% paroxysmal) underwent AI-guided ablation (AI-group). AI targets were 550 for anterior/roof and 400 for posterior/inferior left atrial segments. Procedural and clinical outcomes of these patients were compared to 89 propensity-matched controls who underwent CF-guided ablation (CF-group). All 178 procedures were otherwise similar, and both groups were followed-up for 12 months. The last 25 patients from each group underwent analysis of all VisiTags™ for ablation duration, CF, Force-Time Integral, and impedance drop. RESULTS First-pass pulmonary vein isolation (PVI) was more frequent in AI-group than in CF-group (173 [97%] vs. 149 [84%] circles, P < 0.001), and acute PV reconnection was lower (11 [6%] vs. 24 [13%] circles, P = 0.02). Mean PVI ablation time was similar (AI-group: 42 ± 9 vs. CF-group: 45 ± 14 minutes, P = 0.14). Median impedance drop for AI-group was significantly higher than in CF-group (13.7 [9-19] Ω vs. 8.8 [5.2-13] Ω, P < 0.001). Two major complications occurred in CF-group and none in AI-group. Atrial tachyarrhythmia recurrence was significantly lower in AI-group (15 of 89 [17%]) than in CF-group (33 of 89 [37%], P = 0.002). CONCLUSION AI-guided ablation is associated with significant improvements in the incidence of acute PV reconnection and atrial tachyarrhythmia recurrence rate compared to CF-guided ablation, potentially due to creation of better quality lesions as suggested by greater impedance drop.
Collapse
Affiliation(s)
- Ahmed Hussein
- Institute of Cardiovascular Medicine and Science, Department of Cardiology, Liverpool Heart and Chest Hospital, Liverpool, UK
| | - Moloy Das
- Department of Cardiology, Freeman Hospital, Newcastle upon Tyne, UK
| | - Vivek Chaturvedi
- Institute of Cardiovascular Medicine and Science, Department of Cardiology, Liverpool Heart and Chest Hospital, Liverpool, UK
| | - Issa Khalil Asfour
- Institute of Cardiovascular Medicine and Science, Department of Cardiology, Liverpool Heart and Chest Hospital, Liverpool, UK
| | - Niji Daryanani
- Institute of Cardiovascular Medicine and Science, Department of Cardiology, Liverpool Heart and Chest Hospital, Liverpool, UK
| | - Maureen Morgan
- Institute of Cardiovascular Medicine and Science, Department of Cardiology, Liverpool Heart and Chest Hospital, Liverpool, UK
| | - Christina Ronayne
- Institute of Cardiovascular Medicine and Science, Department of Cardiology, Liverpool Heart and Chest Hospital, Liverpool, UK
| | - Matthew Shaw
- Institute of Cardiovascular Medicine and Science, Department of Cardiology, Liverpool Heart and Chest Hospital, Liverpool, UK
| | - Richard Snowdon
- Institute of Cardiovascular Medicine and Science, Department of Cardiology, Liverpool Heart and Chest Hospital, Liverpool, UK
| | - Dhiraj Gupta
- Institute of Cardiovascular Medicine and Science, Department of Cardiology, Liverpool Heart and Chest Hospital, Liverpool, UK
| |
Collapse
|
18
|
Lin H, Chen YH, Hou JW, Lu ZY, Xiang Y, Li YG. Role of contact force-guided radiofrequency catheter ablation for treatment of atrial fibrillation: A systematic review and meta-analysis. J Cardiovasc Electrophysiol 2017; 28:994-1005. [PMID: 28569422 DOI: 10.1111/jce.13264] [Citation(s) in RCA: 30] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/08/2017] [Revised: 05/21/2017] [Accepted: 05/22/2017] [Indexed: 01/18/2023]
Affiliation(s)
- Hui Lin
- Department of Respiratory; The Second Affiliated Hospital and Yuying Children's Hospital of Wenzhou Medical University; Wenzhou China
| | - Yi-He Chen
- Department of Cardiology; Xinhua Hospital affiliated to the Medical School of Shanghai Jiaotong University; Shanghai China
| | - Jian-Wen Hou
- Department of Cardiology; Xinhua Hospital affiliated to the Medical School of Shanghai Jiaotong University; Shanghai China
| | - Zhao-Yang Lu
- Department of Cardiology; Xinhua Hospital affiliated to the Medical School of Shanghai Jiaotong University; Shanghai China
| | - Yin Xiang
- Department of Cardiology; Xinhua Hospital affiliated to the Medical School of Shanghai Jiaotong University; Shanghai China
| | - Yi-Gang Li
- Department of Cardiology; Xinhua Hospital affiliated to the Medical School of Shanghai Jiaotong University; Shanghai China
| |
Collapse
|
19
|
Luik A, Kunzmann K, Hörmann P, Schmidt K, Radzewitz A, Bramlage P, Schenk T, Schymik G, Merkel M, Kieser M, Schmitt C. Cryoballoon vs. open irrigated radiofrequency ablation for paroxysmal atrial fibrillation: long-term FreezeAF outcomes. BMC Cardiovasc Disord 2017; 17:135. [PMID: 28545407 PMCID: PMC5445510 DOI: 10.1186/s12872-017-0566-6] [Citation(s) in RCA: 17] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/03/2017] [Accepted: 05/11/2017] [Indexed: 11/10/2022] Open
Abstract
Background Effective treatment of paroxysmal atrial fibrillation (AF) is essential for reducing the risk of stroke and heart failure. Cryoballoon (CB) ablation has been developed as an alternative to the use of radiofrequency (RF) energy for electrical isolation of the pulmonary veins. Herein, we provide long-term data regarding the efficacy of CB ablation in comparison to RF. Methods FreezeAF was a randomised non-inferiority study comparing CB ablation with RF ablation for the treatment of patients with drug-refractory paroxysmal AF. Procedural success for the long-term follow-up (30 months) was defined as freedom from AF with an absence of persistent complications. Results Of the 315 patients that were randomised and received catheter ablation, 292 (92.7%) completed the 30-month follow-up (147 in the RF group and 145 in the CB group). The baseline characteristics of the RF and CB groups were similar. Single-procedure success was achieved by 40% of patients in the RF group and 42% of the CB group (p < 0.001 for non-inferiority). When including re-do procedures in the analysis, the multiple procedure success rate was 72% in the RF group and 76% in the CB group. Conclusion The data provide long-term evidence that CB ablation is non-inferior to RF ablation, with high proportions of patients reporting freedom from AF 30 months after the index procedure. Trial registration ClinicalTrials.gov Identifier: NCT00774566; first registered October 16, 2008; first patient included October 20, 2008.
Collapse
Affiliation(s)
- Armin Luik
- Medizinische Klinik IV, Städtisches Klinikum Karlsruhe, Academic Teaching Hospital of the University of Freiburg, Karlsruhe, Germany.
| | - Kevin Kunzmann
- Institute of Medical Biometry and Informatics, University of Heidelberg, Heidelberg, Germany
| | - Patrick Hörmann
- Medizinische Klinik IV, Städtisches Klinikum Karlsruhe, Academic Teaching Hospital of the University of Freiburg, Karlsruhe, Germany
| | - Kerstin Schmidt
- Medizinische Klinik IV, Städtisches Klinikum Karlsruhe, Academic Teaching Hospital of the University of Freiburg, Karlsruhe, Germany
| | - Andrea Radzewitz
- Medizinische Klinik IV, Städtisches Klinikum Karlsruhe, Academic Teaching Hospital of the University of Freiburg, Karlsruhe, Germany
| | - Peter Bramlage
- Institute for Pharmacology and Preventive Medicine, Mahlow, Germany
| | - Thomas Schenk
- Medizinische Klinik IV, Städtisches Klinikum Karlsruhe, Academic Teaching Hospital of the University of Freiburg, Karlsruhe, Germany
| | - Gerhard Schymik
- Medizinische Klinik IV, Städtisches Klinikum Karlsruhe, Academic Teaching Hospital of the University of Freiburg, Karlsruhe, Germany
| | - Matthias Merkel
- Medizinische Klinik IV, Städtisches Klinikum Karlsruhe, Academic Teaching Hospital of the University of Freiburg, Karlsruhe, Germany
| | - Meinhard Kieser
- Institute of Medical Biometry and Informatics, University of Heidelberg, Heidelberg, Germany
| | - Claus Schmitt
- Medizinische Klinik IV, Städtisches Klinikum Karlsruhe, Academic Teaching Hospital of the University of Freiburg, Karlsruhe, Germany
| |
Collapse
|
20
|
Borregaard R, Jensen HK, Tofig BJ, Thrysøe SA, Gerdes C, Nielsen JC, Lukac P. Is the knowledge of contact force beneficial in pulmonary vein antrum isolation? SCAND CARDIOVASC J 2017; 51:129-137. [PMID: 28150508 DOI: 10.1080/14017431.2017.1285043] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 10/20/2022]
Abstract
OBJECTIVE To investigate the effect of the operator knowing the real-time contact force (CF) on the efficacy of pulmonary vein antrum isolation (PVAI). METHODS Fifty patients with paroxysmal atrial fibrillation (AF) or short lasting persistent AF were randomized to CF guided PVAI (n = 25) or conventional PVAI (n = 25). In the CF guided group, CF between 10 and 40 g was aimed at. Efficacy of PVAI was measured as reduction in AF burden (AFB) and time to AF recurrence detected by implantable cardiac monitor (ICM), inserted three months before PVAI. Blanking period was three months and follow-up 12 months. RESULTS All pulmonary veins were isolated in the CF guided group and all but one in the conventional group. Mean CF was 25 g in the CF guided group and 24 g in the conventional group (p = 0.75). Compared to pre-ablation, median [IQR] relative reduction in AFB 3-12 months after ablation was 100 [99-100]% in the CF guided group (p < 0.001) and 99.4 [25-100]% in the conventional group (p < 0.001), not different between groups (p = 0.09). Nine patients (36%) had AF recurrence in the CF guided group and 13 (52%) in the conventional group (p = 0.21, log-rank test). CF differed between operators. When adjusted for operator by regression analysis, patients without recurrent AF had lower proportion of ablation time with CF <10 g than recurrent patients (p = 0.034). No complications occurred. CONCLUSIONS Operator knowledge of real-time CF had no significant effect on AFB reduction or time to AF recurrence. Larger trials should be done to study benefit of real-time CF.
Collapse
Affiliation(s)
- Rune Borregaard
- a Department of Cardiology , Aarhus University Hospital , Aarhus , Denmark
| | | | - Bawer Jalal Tofig
- a Department of Cardiology , Aarhus University Hospital , Aarhus , Denmark
| | | | - Christian Gerdes
- a Department of Cardiology , Aarhus University Hospital , Aarhus , Denmark
| | | | - Peter Lukac
- a Department of Cardiology , Aarhus University Hospital , Aarhus , Denmark
| |
Collapse
|
21
|
Zhou X, Lv W, Zhang W, Ye Y, Li Y, Zhou Q, Xing Q, Zhang J, Lu Y, Zhang L, Wang H, Qin W, Tang B. Impact of contact force technology on reducing the recurrence and major complications of atrial fibrillation ablation: A systematic review and meta-analysis. Anatol J Cardiol 2017; 17:82-91. [PMID: 28209944 PMCID: PMC5336771 DOI: 10.14744/anatoljcardiol.2016.7512] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 11/09/2016] [Indexed: 02/08/2023] Open
Abstract
Contact force (CF) monitoring can be useful in accomplishing circumferential pulmonary vein (PV) isolation for atrial fibrillation (AF). This meta-analysis aimed to assess the efficacy and safety of a CF-sensing catheter in treating AF. Randomized controlled trials or non-randomized observational studies comparing AF ablation using CF-sensing or standard non-CF (NCF)-sensing catheters were identified from PubMed, EMBASE, Cochrane Library, Wanfang Data, and China National Knowledge Infrastructure (January 1, 1998-2016). A total of 19 studies were included. The primary efficacy endpoint was AF recurrence within 12 months, which significantly improved using CF-sensing catheters compared with using NCF-sensing catheters [31.1% vs. 40.5%; risk ratio (RR)=0.82; 95% confidence interval (CI), 0.73-0.93; p<0.05]. Further, the acute PV reconnection (10.1% vs. 24.2%; RR=0.45; 95% CI, 0.32-0.63; p<0.05) and incidence of major complications (1.8% vs. 3.1%; OR=0.59; 95% CI, 0.37-0.95; p<0.05) significantly improved using CF-sensing catheters compared with using NCF-sensing catheters. Procedure parameters such as procedure duration [mean difference (MD)=-28.35; 95% CI, -39.54 to -17.16; p<0.05], ablation time (MD=-3.8; 95% CI, -6.6 to -1.0; p<0.05), fluoroscopy duration (MD=-8.18; 95% CI, -14.11 to -2.24; p<0.05), and radiation dose (standard MD=-0.75; 95% CI, -1.32 to -0.18; p<0.05] significantly reduced using CF-sensing catheters. CF-sensing catheter ablation of AF can reduce the incidence of major complications and generate better outcomes compared with NCF-sensing catheters during the 12-month follow-up period.
Collapse
Affiliation(s)
| | | | | | | | | | | | | | | | | | | | | | | | - Baopeng Tang
- Pacing and Electrophysiological Department, the First Affiliated Hospital of Xinjiang Medical University; Urumqi, Xinjiang-P. R. China.
| |
Collapse
|
22
|
Duytschaever M, O'Neill M, Martinek M. Increasing the Single-Procedure Success Rate of Pulmonary Vein Isolation. Arrhythm Electrophysiol Rev 2017; 6:217-221. [PMID: 29326838 DOI: 10.15420/aer.2017.38/1] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/31/2022] Open
Abstract
To improve the single-procedural success and long-term outcomes of catheter ablation techniques for AF, there is a need for durable, contiguous and transmural lesions encircling the pulmonary veins (PV). Measurement of contact force (CF) between the catheter tip and the target tissue can optimise ablation procedures. A new approach to obtain single-procedure durable PV isolation (PVI) using the latest CF technology combined with the CARTO VISITAG™ Module with Ablation Index (Biosense Webster) has been shown in small studies to almost eliminate recurrence of paroxysmal AF at 1-year follow up and to make PVI procedures more reproducible. The use of a standardised workflow is expected to increase the reproducibility of results and to increase the efficiency of PVI procedures.
Collapse
Affiliation(s)
| | - Mark O'Neill
- St. Thomas' Hospital,London, UK.,King's College London,London, UK
| | | |
Collapse
|
23
|
Sasaki T, Nakamura K, Naito S, Minami K, Koyama K, Yamashita E, Kumagai K, Oshima S. The Right to Left Atrial Volume Ratio Predicts Outcomes after Circumferential Pulmonary Vein Isolation of Longstanding Persistent Atrial Fibrillation. PACING AND CLINICAL ELECTROPHYSIOLOGY: PACE 2016; 39:1181-1190. [PMID: 27641059 DOI: 10.1111/pace.12953] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/30/2016] [Revised: 07/31/2016] [Accepted: 08/31/2016] [Indexed: 12/01/2022]
Abstract
BACKGROUND We aimed to identify the predictors of clinical outcomes after circumferential pulmonary vein isolation (CPVI) without any substrate modification for longstanding persistent atrial fibrillation (LSP-AF). METHODS This study retrospectively analyzed 70 consecutive LSP-AF patients who underwent an initial CPVI and were followed-up for more than 1 year. The right and left atrial volumes indexed to the body surface areas (right atrial volume index [RAVI] and left atrial volume index [LAVI]) were determined by preacquired contrast-enhanced computed tomography (CT). The %RAVI/LAVI was obtained as 100 × RAVI/LAVI. RESULTS During a median follow-up period of 15 months (interquartile range, 13-19 months), 21 patients (30%) had arrhythmia recurrences after the CPVI. Antiarrhythmic drugs were continued in 34 patients (48%). In the Cox proportional hazard model, the %RAVI/LAVI was a significant positive predictor of arrhythmia recurrences (hazard ratio, 1.048; P = 0.039). A receiver-operating characteristic analysis demonstrated that at an optimal cutoff of 100.1 for the %RAVI/LAVI, the sensitivity and specificity for predicting arrhythmia recurrences were 85.7% and 71.4%, respectively. The Kaplan-Meier analysis showed that arrhythmia recurrences were less frequent in patients with a %RAVI/LAVI of <100.1 than in those with a %RAVI/LAVI of ≥100.1 (P < 0.0001), and the arrhythmia-free survival rate at 12 months was 89.7% and 45.2%, respectively. CONCLUSIONS The ratio of the RAVI to LAVI on CT may be a useful predictor of clinical outcomes after CPVI of LSP-AF. LSP-AF patients with a less predominant right atrial enlargement relative to the left atrial enlargement may be good candidates for successful treatment with CPVI alone as the ablation strategy for LSP-AF.
Collapse
Affiliation(s)
- Takehito Sasaki
- Division of Cardiology, Gunma Prefectural Cardiovascular Center, Maebashi City, Gunma, Japan
| | - Kohki Nakamura
- Division of Cardiology, Gunma Prefectural Cardiovascular Center, Maebashi City, Gunma, Japan
| | - Shigeto Naito
- Division of Cardiology, Gunma Prefectural Cardiovascular Center, Maebashi City, Gunma, Japan
| | - Kentaro Minami
- Division of Cardiology, Gunma Prefectural Cardiovascular Center, Maebashi City, Gunma, Japan
| | - Keiko Koyama
- Division of Radiology, Gunma Prefectural Cardiovascular Center, Maebashi City, Gunma, Japan
| | - Eiji Yamashita
- Division of Cardiology, Gunma Prefectural Cardiovascular Center, Maebashi City, Gunma, Japan
| | - Koji Kumagai
- Division of Cardiology, Gunma Prefectural Cardiovascular Center, Maebashi City, Gunma, Japan
| | - Shigeru Oshima
- Division of Cardiology, Gunma Prefectural Cardiovascular Center, Maebashi City, Gunma, Japan
| |
Collapse
|
24
|
Predictors of chronic pulmonary vein reconnections after contact force-guided ablation: importance of completing electrical isolation with circumferential lines and creating sufficient ablation lesion densities. J Interv Card Electrophysiol 2016; 47:321-331. [PMID: 27417148 DOI: 10.1007/s10840-016-0164-z] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/06/2016] [Accepted: 06/29/2016] [Indexed: 10/21/2022]
Abstract
PURPOSE We aimed to identify the predictors of chronic pulmonary vein reconnections (CPVRs) after contact force (CF)-guided circumferential PV isolation (CPVI) of atrial fibrillation (AF). METHODS Forty-nine consecutive patients undergoing second ablation procedures for recurrent AF after CF-guided ablation were retrospectively studied. The CPVI was performed by point-by-point ablation with a target CF of 15-20 g. The incidence of CPVRs was evaluated along the right- and left-sided anterior and posterior CPVI regions (Ant-RPVs, Post-RPVs, Ant-LPVs, and Post-LPVs). RESULTS CPVRs were observed in 30.6, 22.4, 20.4, and 32.7 % of patients along the Ant-RPVs, Post-RPVs, Ant-LPVs, and Post-LPVs, respectively (P = 0.436). In the multivariate logistic analyses, completing a left atrium-PV conduction block with touch-up ablation inside the initially estimated CPVI lines (Ant-RPVs, Post-RPVs, Ant-LPVs, Post-LPVs; odds ratio [OR] 5.747, 15.000, 207.619, 7.940; P = 0.032, 0.004, 0.034, 0.021) and region length (Post-LPVs; OR 3.183, P = 0.027) were positive predictors of CPVRs, while the mean CF (Ant-RPVs; OR 0.861, P = 0.045) and number of radiofrequency applications per unit length (Ant-LPVs, Post-LPVs; OR 0.038, 0.122; P = 0.034, 0.029) were negative predictors. At optimal cutoffs of 5.8 cm for the region length, 14.2 g for the mean CF, and 1.97/cm (Ant-LPVs) and 2.01/cm (Post-LPVs) for the radiofrequency application density, the sensitivity and specificity were 93.8 and 63.6 %, 60.0 and 76.5 %, 90.0 and 64.1 %, and 75.0 and 63.6 %, respectively. CONCLUSIONS Completing PVI with circumferential lines without touch-up ablation and creating a sufficient density of radiofrequency ablation lesions on the lines with a sufficient CF may be necessary to prevent CPVRs after a CF-guided CPVI.
Collapse
|
25
|
Liang JJ, Santangeli P. Contact force sensing during atrial fibrillation ablation: clinical experience and effects on outcomes. Expert Rev Cardiovasc Ther 2016; 14:749-59. [DOI: 10.1586/14779072.2016.1168695] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/18/2023]
|