1
|
Zhan M, Yao H, Xie Q, Wang Y, Zhou Y. Evaluation of electrode-tissue contact using multifrequency impedance analysis and Cole-Cole model fitting. Proc Inst Mech Eng H 2025; 239:370-380. [PMID: 40219918 DOI: 10.1177/09544119251330742] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 04/14/2025]
Abstract
Atrial fibrillation (AF) is a common cardiac arrhythmia, and ablation is the primary treatment for patients with drug intolerance. The success of AF ablation depends on the adhesion of the catheter to the tissue. Existing electrical coupling index (ECI) and electrode-interface resistance (IR) methods based on impedance measurement to evaluate the adhesion between catheters and tissues do not explore the internal changes of the tissue during the compression process. This study introduces a new method to understand these internal changes using multi-frequency impedance combined with Cole-Cole model fitting, which is critical for accurate characterization of the contact between catheter and tissue. We used four-electrodes impedance measurement, using customized circuits and compression platform, applying 5-400 g (3.6-228.2 Pa) pressure to the bullfrog thighs to collect impedance data at frequencies of 500-100 kHz. The Cole-Cole model was then used for data fitting and analysis. The customized circuit accurately detects impedance up to 2 kΩ with less than 5% amplitude error, less than 15% phase error, and less than 6% error in model component values. Correlation analysis showed a significant linear relationship between extracellular fluid resistance and applied pressure (Pearson R ≈ 0.9, p < 0.05), indicating that extracellular fluid resistance increases with compression. This suggests that there is a significant linear positive correlation between the extracellular fluid resistance and the applied pressure, meaning that as the pressure increases, the extracellular fluid resistance correspondingly rises. This may provide a new perspective for studying the degree of catheter-tissue contact during atrial fibrillation ablation procedures.
Collapse
Affiliation(s)
- Mengying Zhan
- School of Health Science and Engineering, University of Shanghai for Science and Technology, Shanghai, China
| | - Haitao Yao
- School of Health Science and Engineering, University of Shanghai for Science and Technology, Shanghai, China
| | - Qijun Xie
- School of Health Science and Engineering, University of Shanghai for Science and Technology, Shanghai, China
| | - Yingxi Wang
- School of Health Science and Engineering, University of Shanghai for Science and Technology, Shanghai, China
| | - Yu Zhou
- School of Health Science and Engineering, University of Shanghai for Science and Technology, Shanghai, China
| |
Collapse
|
2
|
Nair GM, Birnie DH, Wells GA, Nery PB, Redpath CJ, Sarrazin JF, Roux JF, Parkash R, Bernier M, Sterns LD, Novak P, Veenhuyzen G, Morillo CA, Singh SM, Sturmer M, Chauhan VS, Angaran P, Essebag V. Augmented wide area circumferential catheter ablation for reduction of atrial fibrillation recurrence (AWARE) trial: Design and rationale. Am Heart J 2022; 248:1-12. [PMID: 35219715 DOI: 10.1016/j.ahj.2022.02.009] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/08/2021] [Revised: 02/03/2022] [Accepted: 02/19/2022] [Indexed: 11/15/2022]
Abstract
BACKGROUND Recurrence of atrial fibrillation (AF) after a pulmonary vein isolation procedure is often due to electrical reconnection of the pulmonary veins. Repeat ablation procedures may improve freedom from AF but are associated with increased risks and health care costs. A novel ablation strategy in which patients receive "augmented" ablation lesions has the potential to reduce the risk of AF recurrence. OBJECTIVE The Augmented Wide Area Circumferential Catheter Ablation for Reduction of Atrial Fibrillation Recurrence (AWARE) Trial was designed to evaluate whether an augmented wide-area circumferential antral (WACA) ablation strategy will result in fewer atrial arrhythmia recurrences in patients with symptomatic paroxysmal AF, compared with a conventional WACA strategy. METHODS/DESIGN The AWARE trial was a multicenter, prospective, randomized, open, blinded endpoint trial that has completed recruitment (ClinicalTrials.gov NCT02150902). Patients were randomly assigned (1:1) to either the control arm (single WACAlesion set) or the interventional arm (augmented- double WACA lesion set performed after the initial WACA). The primary outcome was atrial tachyarrhythmia (AA; atrial tachycardia [AT], atrial flutter [AFl] or AF) recurrence between days 91 and 365 post catheter ablation. Patient follow-up included 14-day continuous ambulatory ECG monitoring at 3, 6, and 12 months after catheter ablation. Three questionnaires were administered during the trial- the EuroQuol-5D (EQ-5D) quality of life scale, the Canadian Cardiovascular Society Severity of Atrial Fibrillation scale, and a patient satisfaction scale. DISCUSSION The AWARE trial was designed to evaluate whether a novel approach to catheter ablation reduced the risk of AA recurrence in patients with symptomatic paroxysmal AF.
Collapse
Affiliation(s)
- Girish M Nair
- University of Ottawa Heart Institute, Ottawa, Canada
| | | | | | - Pablo B Nery
- University of Ottawa Heart Institute, Ottawa, Canada
| | | | | | | | - Ratika Parkash
- Queen Elizabeth II Health Sciences, Halifax, Nova Scotia, Canada
| | - Martin Bernier
- McGill University Health Centre, Montreal, Quebec, Canada
| | - Laurence D Sterns
- Victoria Cardiac Arrhythmia Trials, Victoria, British Columbia, Canada
| | - Paul Novak
- Victoria Cardiac Arrhythmia Trials, Victoria, British Columbia, Canada
| | - George Veenhuyzen
- Libin Cardiovascular Institute, University of Calgary, Calgary, Alberta, Canada
| | - Carlos A Morillo
- Libin Cardiovascular Institute, University of Calgary, Calgary, Alberta, Canada
| | | | - Marcio Sturmer
- Hôpital Sacré-Cœur de Montréal, Montréal, Québec, Canada
| | - Vijay S Chauhan
- University Health Network, Toronto General Hospital, Toronto, Ontario, Canada
| | - Paul Angaran
- St. Michael's Hospital, University of Toronto, Toronto, Ontario, Canada
| | - Vidal Essebag
- McGill University Health Centre, Montreal, Quebec, Canada; Hôpital Sacré-Cœur de Montréal, Montréal, Québec, Canada
| |
Collapse
|
3
|
Ducceschi V, Zingarini G, Nigro G, Brasca FMA, Malacrida M, Carbone A, Lavalle C, Maglia G, Infusino T, Aloia A, Nicolis D, Auricchio C, Uccello A, Notaristefano F, Rago A, Botto GL, Esposito L. Optimized radiofrequency lesions through local impedance guidance for effective CTI ablation in right atrial flutter. Pacing Clin Electrophysiol 2022; 45:612-618. [PMID: 35383979 DOI: 10.1111/pace.14482] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/23/2021] [Revised: 01/31/2022] [Accepted: 02/20/2022] [Indexed: 11/30/2022]
Abstract
BACKGROUND Although radiofrequency (RF) catheter ablation of cavo-tricuspid isthmus (CTI) is an established treatment for typical right atrial flutter (RAFL), it remains to be established whether local tissue impedance (LI) is able to predict effective CTI ablation and what LI drop values during ablation should be used to judge a lesion as effective. We aimed to investigate the ability of LI to predict ablation efficacy in patients with RAFL. METHODS RF delivery was guided by the DirectSense™ algorithm. Successful single RF application was defined according to a defragmentation of atrial potentials (DAP), reduction of voltage (RedV) by at least 80% or changes on unipolar electrogram (UPC). The ablation endpoint was the creation of bidirectional conduction block (BDB) across the isthmus. RESULTS 392 point-by-point RF applications were analyzed in 48 consecutive RAFL patients. The mean baseline LI was 105.4±12Ω prior to ablation and 92.0±11Ω after ablation (p<0.0001). According to validation criteria, absolute drops in impedance were larger at successful ablation sites than at ineffective ablation sites (DAP: 17.8±6Ω vs 8.7±4Ω; RedV: 17.2±6Ω vs 7.8±5Ω; UPC: 19.6±6Ω vs 10.1±5Ω, all p<0.0001). LI drop values significantly increased according to the number of criteria satisfied (ranging from 7.5Ω to 19.9). BDB was obtained in all cases. No procedure-related adverse events were reported. CONCLUSIONS A LI-guided approach to CTI ablation was safe and effective in treating RAFL. The magnitude of LI drop was associated with effective lesion formation and BDB and could be used as a marker of ablation efficacy. CLINICAL TRIAL REGISTRATION Catheter Ablation of Arrhythmias with a High-Density Mapping System in Real-World Practice (CHARISMA). URL: http://clinicaltrials.gov/ Identifier: NCT03793998. This article is protected by copyright. All rights reserved.
Collapse
Affiliation(s)
| | | | - Gerardo Nigro
- Department of Cardiology, Monaldi Hospital, Naples, Italy
| | | | | | | | | | | | | | - Antonio Aloia
- Division of Cardiology, Presidio Ospedaliero di Vallo della Lucania, Italy
| | | | | | | | | | - Anna Rago
- Department of Cardiology, Monaldi Hospital, Naples, Italy
| | - Giovanni Luca Botto
- ASST Rhodense, Civile Hospital Rho and Salvini Hospital Garbagnate Milanese Hospital, Milan, Italy
| | | |
Collapse
|
4
|
Sasaki T, Nakamura K, Minami K, Take Y, Nakatani Y, Miki Y, Goto K, Kaseno K, Yamashita E, Koyama K, Naito S. Local impedance measurements during contact force-guided cavotricuspid isthmus ablation for predicting an effective radiofrequency ablation. J Arrhythm 2022; 38:245-252. [PMID: 35387143 PMCID: PMC8977576 DOI: 10.1002/joa3.12680] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/13/2021] [Revised: 01/05/2022] [Accepted: 01/16/2022] [Indexed: 01/13/2023] Open
Abstract
Background An ablation catheter capable of contact force (CF) and local impedance (LI) monitoring (IntellaNav StablePoint, Boston Scientific) has been recently launched. We evaluated the relationship between the CF and LI values during radiofrequency catheter ablation (RFCA) along the cavotricuspid isthmus (CTI). Methods Fifty consecutive subjects who underwent a CTI-RFCA using IntellaNav StablePoint catheters were retrospectively studied. The initial CF and LI at the start of the RF applications and mean CF and minimum LI during the RF applications were measured. The absolute and percentage LI drops were calculated as the difference between the initial and minimum LIs and 100 × absolute LI drop/initial LI, respectively. Results We analyzed 602 first-pass RF applications. A weak correlation was observed between the initial CF and LI (r = 0.13) and between the mean CF and LI drops (r = 0.22). The initial LI and absolute and percentage LI drops were greater at effective ablation sites than ineffective ablation sites (median, 151 vs. 138 Ω, 22 vs. 14 Ω, and 14.4% vs. 9.9%; p < .001), but the initial and mean CF did not differ. At optimal cutoffs of 21 Ω and 10.8% for the absolute and percentage LI drops according to the receiver-operating characteristic analysis, the sensitivity, and specificity for predicting an effective ablation were 57.4% and 88.9% and 80.0%, and 61.1%, respectively. Conclusions The effective sites during the CF-guided CTI-RFCA had greater initial LI and LI drops than the ineffective sites. Absolute and percentage LI drops of 21 Ω and 10.8% may be appropriate targets for an effective ablation.
Collapse
Affiliation(s)
- Takehito Sasaki
- Division of CardiologyGunma Prefectural Cardiovascular CenterMaebashi CityJapan
| | - Kohki Nakamura
- Division of CardiologyGunma Prefectural Cardiovascular CenterMaebashi CityJapan
| | - Kentaro Minami
- Division of CardiologyGunma Prefectural Cardiovascular CenterMaebashi CityJapan
| | - Yutaka Take
- Division of CardiologyGunma Prefectural Cardiovascular CenterMaebashi CityJapan
| | - Yosuke Nakatani
- Division of CardiologyGunma Prefectural Cardiovascular CenterMaebashi CityJapan
| | - Yuko Miki
- Division of CardiologyGunma Prefectural Cardiovascular CenterMaebashi CityJapan
| | - Koji Goto
- Division of CardiologyGunma Prefectural Cardiovascular CenterMaebashi CityJapan
| | - Kenichi Kaseno
- Division of CardiologyGunma Prefectural Cardiovascular CenterMaebashi CityJapan
| | - Eiji Yamashita
- Division of CardiologyGunma Prefectural Cardiovascular CenterMaebashi CityJapan
| | - Keiko Koyama
- Division of RadiologyGunma Prefectural Cardiovascular CenterMaebashi CityJapan
| | - Shigeto Naito
- Division of CardiologyGunma Prefectural Cardiovascular CenterMaebashi CityJapan
| |
Collapse
|
5
|
Sasaki T, Nakamura K, Inoue M, Minami K, Miki Y, Goto K, Take Y, Kaseno K, Yamashita E, Koyama K, Naito S. Optimal local impedance drops for an effective radiofrequency ablation during cavo-tricuspid isthmus ablation. J Arrhythm 2020; 36:905-911. [PMID: 33024468 PMCID: PMC7532274 DOI: 10.1002/joa3.12403] [Citation(s) in RCA: 17] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/12/2020] [Revised: 06/17/2020] [Accepted: 06/27/2020] [Indexed: 12/15/2022] Open
Abstract
PURPOSE A novel ablation catheter capable of local impedance (LI) monitoring (IntellaNav MiFi OI, Boston Scientific) has been recently introduced to clinical practice. We aimed to determine the optimal LI drops for an effective radiofrequency ablation during cavo-tricuspid isthmus (CTI) ablation. METHODS This retrospective observational study enrolled 50 consecutive patients (68 ± 9 years; 34 males) who underwent a CTI ablation using the IntellaNav MiFi OI catheter, guided by Rhythmia. The LI at the start of radiofrequency applications (initial LI) and minimum LI during radiofrequency applications were evaluated. The absolute and percentage LI drops were defined as the difference between the initial and minimum LIs and 100× absolute LI drop/initial LI, respectively. RESULTS A total of 518 radiofrequency applications were analyzed. The absolute and percentage LI drops were significantly greater at effective ablation sites than ineffective sites (median, 15 ohms vs 8 ohms, P < .0001; median, 14.7% vs 8.3%, P < .0001). A receiver-operating characteristic analysis demonstrated that at optimal cutoffs of 12 ohms and 11.6% for the absolute and percentage LI drops, the sensitivity and specificity for predicting the effectiveness of the ablation were 66.5% and 88.2%, and 65.1% and 88.2%, respectively. Finally, bidirectional conduction block along the CTI was achieved in all patients. CONCLUSIONS During the LI-guided CTI ablation, the effective RF ablation sites exhibited significantly greater absolute and percentage LI drops than the ineffective RF ablation sites. Absolute and percentage LI drops of 12 ohms and 11.6% may be suitable targets for effective ablation.
Collapse
Affiliation(s)
- Takehito Sasaki
- Division of Cardiology Gunma Prefectural Cardiovascular Center Maebashi City Japan
| | - Kohki Nakamura
- Division of Cardiology Gunma Prefectural Cardiovascular Center Maebashi City Japan
| | - Mitsuho Inoue
- Division of Cardiology Gunma Prefectural Cardiovascular Center Maebashi City Japan
| | - Kentaro Minami
- Division of Cardiology Gunma Prefectural Cardiovascular Center Maebashi City Japan
| | - Yuko Miki
- Division of Cardiology Gunma Prefectural Cardiovascular Center Maebashi City Japan
| | - Koji Goto
- Division of Cardiology Gunma Prefectural Cardiovascular Center Maebashi City Japan
| | - Yutaka Take
- Division of Cardiology Gunma Prefectural Cardiovascular Center Maebashi City Japan
| | - Kenichi Kaseno
- Division of Cardiology Gunma Prefectural Cardiovascular Center Maebashi City Japan
| | - Eiji Yamashita
- Division of Cardiology Gunma Prefectural Cardiovascular Center Maebashi City Japan
| | - Keiko Koyama
- Division of Radiology Gunma Prefectural Cardiovascular Center Maebashi City Japan
| | - Shigeto Naito
- Division of Cardiology Gunma Prefectural Cardiovascular Center Maebashi City Japan
| |
Collapse
|
6
|
Zhang T, Wang Y, Han Z, Zhao H, Liang Z, Wang Y, Wu Y, Ren X. Cavotricuspid isthmus ablation using ablation index in typical right atrial flutter. J Cardiovasc Electrophysiol 2019; 30:2414-2419. [PMID: 31502295 DOI: 10.1111/jce.14156] [Citation(s) in RCA: 16] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/24/2019] [Revised: 07/10/2019] [Accepted: 08/23/2019] [Indexed: 12/13/2022]
Affiliation(s)
- Tao Zhang
- Department of Cardiology Beijing Anzhen Hospital Affiliated to Capital Medical University Beijing China
| | - Yunlong Wang
- Department of Cardiology Beijing Anzhen Hospital Affiliated to Capital Medical University Beijing China
| | - Zhihong Han
- Department of Cardiology Beijing Anzhen Hospital Affiliated to Capital Medical University Beijing China
| | - Hua Zhao
- Department of Cardiology Beijing Anzhen Hospital Affiliated to Capital Medical University Beijing China
| | - Zhuo Liang
- Department of Cardiology Beijing Anzhen Hospital Affiliated to Capital Medical University Beijing China
| | - Ye Wang
- Department of Cardiology Beijing Anzhen Hospital Affiliated to Capital Medical University Beijing China
| | - Yongquan Wu
- Department of Cardiology Beijing Anzhen Hospital Affiliated to Capital Medical University Beijing China
| | - Xuejun Ren
- Department of Cardiology Beijing Anzhen Hospital Affiliated to Capital Medical University Beijing China
| |
Collapse
|