Iwakawa H, Takigawa M, Nakada K, Yamamoto T, Ikenouchi T, Masumura M, Negishi M, Kawamura I, Goto K, Shigeta T, Nishimura T, Takamiya T, Tao S, Miyazaki S, Goya M, Watanabe H, Sasano T. Efficacy and Safety of High-Power Short-Duration Ablation for Cavo-Tricuspid Isthmus With a Flexible-Tip Temperature-Controlled Power Regulation Catheter Performed by Electrophysiology Trainees. J Cardiovasc Electrophysiol 2025; 36:367-375. [PMID: 39663774 DOI: 10.1111/jce.16516] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/28/2024] [Revised: 10/24/2024] [Accepted: 11/14/2024] [Indexed: 12/13/2024]
Abstract
INTRODUCTION The suitability of high-power short-duration (HPSD) cavo-tricuspid isthmus ablation (CTI-Abl) for electrophysiology (EP) trainees, as well as the underlying mechanisms of its efficacy, remain unknown. The aim of this study was to clarify the efficacy and safety of HPSD CTI-Abl performed by EP trainees and assess lesion characteristics between HPSD and moderate-power long duration (MPLD) ablations. METHODS Study 1: CTI-Abl was performed by first- to fourth-year EP trainees in consecutive 113 patients (67 ± 11 years, 27.2% female). Study cohort was historically divided into three groups: MPLD (30-35 W for up to 30 s) using TactiCath (TC-MPLD, N = 38) and MPLD and HPSD (50 W for 12 s) using TactiFlex (TF-MPLD, N = 23; TF-HPSD, N = 52). Primary endpoint was first-pass bidirectional isthmus block (BIB). Study 2: lesion geometries created by each ablation strategy were compared using an ex-vivo model. RESULTS Study 1: TF-HPSD ablation strategy demonstrated a higher success rate of first-pass BIB than MPLD protocol (TC-MPLD, 58%; TF-MPLD, 48%; TF-HPSD, 94%, p < 0.001), without any complications. TF-HPSD group was associated with shorter total procedure and RF application times, as well as fewer ablation points and gaps, compared to the MPLD groups. Study 2: TF-HPSD created greater lesion surface length, width, and area than MPLD strategies. CONCLUSION HPSD CTI-Abl performed by EP trainees using TactiFlex SE catheter demonstrated a higher first-pass BIB rate, shorter total procedure and RF application times, and fewer ablation points and gaps compared to the conventional method, without increasing complication rates.
Collapse
Affiliation(s)
- Hidehiro Iwakawa
- Department of Cardiovascular Medicine, Tokyo Medical and Dental University, Tokyo, Japan
- Department of Cardiovascular Medicine, Akita University Graduate School of Medicine, Akita, Japan
| | - Masateru Takigawa
- Department of Cardiovascular Medicine, Tokyo Medical and Dental University, Tokyo, Japan
| | - Kosuke Nakada
- Department of Cardiovascular Medicine, Tokyo Medical and Dental University, Tokyo, Japan
| | - Tasuku Yamamoto
- Department of Cardiovascular Medicine, Tokyo Medical and Dental University, Tokyo, Japan
| | - Takashi Ikenouchi
- Department of Cardiovascular Medicine, Tokyo Medical and Dental University, Tokyo, Japan
| | - Mayumi Masumura
- Department of Cardiovascular Medicine, Tokyo Medical and Dental University, Tokyo, Japan
| | - Miho Negishi
- Department of Cardiovascular Medicine, Tokyo Medical and Dental University, Tokyo, Japan
| | - Iwanari Kawamura
- Department of Cardiovascular Medicine, Tokyo Medical and Dental University, Tokyo, Japan
| | - Kentaro Goto
- Department of Cardiovascular Medicine, Tokyo Medical and Dental University, Tokyo, Japan
| | - Takatoshi Shigeta
- Department of Cardiovascular Medicine, Tokyo Medical and Dental University, Tokyo, Japan
| | - Takuro Nishimura
- Department of Cardiovascular Medicine, Tokyo Medical and Dental University, Tokyo, Japan
| | - Tomomasa Takamiya
- Department of Cardiovascular Medicine, Tokyo Medical and Dental University, Tokyo, Japan
| | - Susumu Tao
- Department of Cardiovascular Medicine, Tokyo Medical and Dental University, Tokyo, Japan
| | - Shinsuke Miyazaki
- Department of Cardiovascular Medicine, Tokyo Medical and Dental University, Tokyo, Japan
| | - Masahiko Goya
- Department of Cardiovascular Medicine, Tokyo Medical and Dental University, Tokyo, Japan
| | - Hiroyuki Watanabe
- Department of Cardiovascular Medicine, Akita University Graduate School of Medicine, Akita, Japan
| | - Tetsuo Sasano
- Department of Cardiovascular Medicine, Tokyo Medical and Dental University, Tokyo, Japan
| |
Collapse
|
2
|
Bahlke F, Wachter A, Erhard N, Englert F, Syväri J, Krafft H, Popa M, Abdiu E, Lennerz C, Telishevska M, Lengauer S, Reents T, Hessling G, Deisenhofer I, Bourier F. Radiofrequency ablation-Real-time visualization of lesions and their correlation with underlying parameters. Pacing Clin Electrophysiol 2024; 47:994-1003. [PMID: 38728067 DOI: 10.1111/pace.14992] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/12/2023] [Revised: 03/10/2024] [Accepted: 04/09/2024] [Indexed: 08/07/2024]
Abstract
BACKGROUND Lesion durability and transmurality are crucial for successful radiofrequency (RF) ablation. This study provides a model of real-time RF lesion visualization and insights into the role of underlying parameters, as local impedance (LI). METHODS A force-sensing, LI-sensing catheter was used for lesion creation in an ex vivo model involving cross-sections of porcine cardiac preparations. During 60 s of RF application, one measurement per second was performed regarding lesion size and available ablation parameters. In total, 1847 measurements from n = 36 lesions were performed. Power (20-50 W) and contact force (1-5 g, 10-15 g, 20-25 g) were systematically alternated. RESULTS Lesion formation was most prominent in the first seconds of RF application during which nonlinear lesion growth was observed (max. 1.08 mm/s for lesion depth and 2.71 mm/s for lesion diameter). Power levels determined the extent of lesion formation in the early phase. After 20 s, lesion size growth velocity approaches 0.1 mm/s at all power levels. LI changes were also highest in the first seconds (up to - 12 Ω/s) and decreased to less than - 0.1Ω/s after prolonged application. CONCLUSION Lesion formation in irrigated RF ablation is a nonlinear process. Final lesion size resulting from an RF application is mainly influenced by high rates of lesion growth in the first seconds of ablation. LI seems to be a good surrogate for differentiating changes in lesion formation.
Collapse
Affiliation(s)
- Fabian Bahlke
- Department of Electrophysiology, German Heart Center Munich, Technical University Munich, Munich, Germany
| | - Andreas Wachter
- Department of Electrophysiology, German Heart Center Munich, Technical University Munich, Munich, Germany
| | - Nico Erhard
- Department of Electrophysiology, German Heart Center Munich, Technical University Munich, Munich, Germany
| | - Florian Englert
- Department of Electrophysiology, German Heart Center Munich, Technical University Munich, Munich, Germany
| | - Jan Syväri
- Department of Electrophysiology, German Heart Center Munich, Technical University Munich, Munich, Germany
| | - Hannah Krafft
- Department of Electrophysiology, German Heart Center Munich, Technical University Munich, Munich, Germany
| | - Miruna Popa
- Department of Electrophysiology, German Heart Center Munich, Technical University Munich, Munich, Germany
| | - Edison Abdiu
- Department of Electrophysiology, German Heart Center Munich, Technical University Munich, Munich, Germany
| | - Carsten Lennerz
- Department of Electrophysiology, German Heart Center Munich, Technical University Munich, Munich, Germany
| | - Marta Telishevska
- Department of Electrophysiology, German Heart Center Munich, Technical University Munich, Munich, Germany
| | - Sarah Lengauer
- Department of Electrophysiology, German Heart Center Munich, Technical University Munich, Munich, Germany
| | - Tilko Reents
- Department of Electrophysiology, German Heart Center Munich, Technical University Munich, Munich, Germany
| | - Gabriele Hessling
- Department of Electrophysiology, German Heart Center Munich, Technical University Munich, Munich, Germany
| | - Isabel Deisenhofer
- Department of Electrophysiology, German Heart Center Munich, Technical University Munich, Munich, Germany
| | - Felix Bourier
- Department of Electrophysiology, German Heart Center Munich, Technical University Munich, Munich, Germany
| |
Collapse
|
3
|
Takigawa M, Yamaguchi J, Goya M, Iwakawa H, Yamamoto T, Amemiya M, Ikenouchi T, Negishi M, Kawamura I, Goto K, Shigeta T, Nishimura T, Takamiya T, Tao S, Ohuchi K, Suzuki S, Miyazaki S, Sasano T. An optimized approach for increasing lesion size in temperature-controled setting using a catheter with a surface thermocouple and efficient irrigation. J Arrhythm 2024; 40:536-551. [PMID: 38939786 PMCID: PMC11199823 DOI: 10.1002/joa3.13040] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/17/2024] [Revised: 03/15/2024] [Accepted: 04/07/2024] [Indexed: 06/29/2024] Open
Abstract
Background We explore an optimized approach for increasing lesion size using a novel ablation catheter with a surface thermocouple and efficient irrigation in a temperature-control setting. Methods We conducted radiofrequency applications at various power levels (35 W, 40 W, and 45 W), contact forces (CFs, 10 g/20 g), and durations (60 s/120 s/180 s) in perpendicular/parallel catheter orientations, with normal saline irrigation (NS-irrigation) and Half NS-irrigation (HNS-irrigation) in an ex-vivo model (Step 1). In addition, we performed applications (35 W/40 W/45 W for 60 s/120 s/180 s in NS-irrigation and 35 W/40 W for 60 s/120 s/180 s in HNS-irrigation) in four swine (Step 2), evaluating lesion characteristics and the occurrence of steam pops. Results In Step 1, out of 288 lesions, we observed 47 (16.3%) steam pops, with 13 in NS-irrigation and 34 in HNS-irrigation (p = .001). Although steam pops were mostly observed with the most aggressive setting (45 W/180 s, 54%) with NS-irrigation, they happened in less aggressive settings with HNS irrigation. Lesion size significantly increased with longer-duration ablation but not with HNS-irrigation. The optimal %impedance-drop cutoff to predict steam pops was 20% with a negative-predictive-value (NPV) = 95.1% including NS- and HNS-irrigation groups, and 22% with an NPV = 96.1% in NS-irrigation group. In Step 2, similar to the ex-vivo model, lesion size significantly increased with longer-duration ablation but not with HNS-irrigation. Steam pops were absent with NS-irrigation (0/35) even with the largest %impedance-drop reaching 31% at 45 W/180 s. All steam pops were observed with HNS-irrigation (6/21, 29%). The optimal %impedance-drop cutoff predicting steam pops was 24% with an NPV = 96.3% including both NS- and HNS-irrigation groups. Conclusions Rather than using HNS-irrigation, very long-duration of radiofrequency applications up to 45 W/180 s may be recommended to safely and effectively increase lesion dimensions using this catheter with NS-irrigation.
Collapse
Affiliation(s)
- Masateru Takigawa
- Department of Cardiovascular MedicineTokyo Medical and Dental University HospitalTokyoJapan
- Division of Advanced Arrhythmia ResearchTokyo Medical and Dental University HospitalTokyoJapan
| | - Junji Yamaguchi
- Department of Cardiovascular MedicineTokyo Medical and Dental University HospitalTokyoJapan
| | - Masahiko Goya
- Department of Cardiovascular MedicineTokyo Medical and Dental University HospitalTokyoJapan
| | - Hidehiro Iwakawa
- Department of Cardiovascular MedicineAkita University Graduate School of MedicineAkitaJapan
| | - Tasuku Yamamoto
- Department of Cardiovascular MedicineTokyo Medical and Dental University HospitalTokyoJapan
| | - Miki Amemiya
- Department of Cardiovascular MedicineTokyo Medical and Dental University HospitalTokyoJapan
| | - Takashi Ikenouchi
- Department of Cardiovascular MedicineTokyo Medical and Dental University HospitalTokyoJapan
| | - Miho Negishi
- Department of Cardiovascular MedicineTokyo Medical and Dental University HospitalTokyoJapan
| | - Iwanari Kawamura
- Department of Cardiovascular MedicineTokyo Medical and Dental University HospitalTokyoJapan
| | - Kentaro Goto
- Department of Cardiovascular MedicineTokyo Medical and Dental University HospitalTokyoJapan
- Division of Advanced Arrhythmia ResearchTokyo Medical and Dental University HospitalTokyoJapan
| | - Takatoshi Shigeta
- Department of Cardiovascular MedicineTokyo Medical and Dental University HospitalTokyoJapan
| | - Takuro Nishimura
- Department of Cardiovascular MedicineTokyo Medical and Dental University HospitalTokyoJapan
| | - Tomomasa Takamiya
- Department of Cardiovascular MedicineTokyo Medical and Dental University HospitalTokyoJapan
| | - Susumu Tao
- Department of Cardiovascular MedicineTokyo Medical and Dental University HospitalTokyoJapan
| | - Katsuhiro Ohuchi
- Center for Experimental AnimalsTokyo Medical and Dental UniversityTokyoJapan
| | | | - Shinsuke Miyazaki
- Department of Cardiovascular MedicineTokyo Medical and Dental University HospitalTokyoJapan
- Division of Advanced Arrhythmia ResearchTokyo Medical and Dental University HospitalTokyoJapan
| | - Tetsuo Sasano
- Department of Cardiovascular MedicineTokyo Medical and Dental University HospitalTokyoJapan
| |
Collapse
|
4
|
Yamaguchi J, Takigawa M, Goya M, Martin CA, Negishi M, Yamamoto T, Ikenouchi T, Goto K, Shigeta T, Kawamura I, Nishimura T, Takamiya T, Tao S, Miyazaki S, Sasano T. Impact of contact force on the lesion characteristics of very high-power short-duration ablation using a QDOT-MICRO catheter. J Arrhythm 2024; 40:247-255. [PMID: 38586837 PMCID: PMC10995585 DOI: 10.1002/joa3.12992] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/06/2023] [Revised: 01/05/2024] [Accepted: 01/06/2024] [Indexed: 04/09/2024] Open
Abstract
Background Lesion size is reported to become larger as contact force (CF) increases. However, this has not been systematically evaluated in temperature-guided very high-power short-duration (vHPSD) ablation, which was therefore the purpose of this study. Methods Radiofrequency applications (90 W/4 s, temperature-control mode) were performed in excised porcine myocardium with four different CFs of 5, 15, 25, and 35 g using QDOT-MICRO™ catheter. Ten lesions for each combination of settings were created, and lesion metrics and steam-pops were compared. Results A total of 320 lesions were analyzed. Lesion depth, surface area, and volume were smallest for CF of 5 g than for 15, 25, and 35 g (depth: 2.7 mm vs. 2.9 mm, 3.0 mm, 3.15 mm, p < .01; surface area: 38.4 mm2 vs. 41.8 mm2, 43.3 mm2, 41.5 mm2, p < .05; volume: 98.2 mm3 vs. 133.3 mm3, 129.4 mm3, 126.8 mm3, p < .01 for all pairs of groups compared to CF = 5 g). However, no significant differences were observed between CFs of 15-35 g. Average power was highest for CF of 5 g, followed by 15, 25, and 35 g (83.2 W vs. 82.1 W vs. 77.1 W vs. 66.1 W, p < .01 for all pairs), reflecting the higher incidence of temperature-guided power titration with greater CFs (5 g:8.8% vs. 15 g:52.5% vs. 25 g:77.5% vs. 35 g:91.2%, p < .01 for all pairs except for 25 g vs. 35 g). The incidence of steam-pops did not significantly differ between four groups (5 g:3.8% vs. 15 g:10% vs. 25 g:6.2% vs. 35 g:2.5%, not significant for all pairs). Conclusions For vHPSD ablation, lesion size does not become large once the CF reaches 15 g, and the risk of steam-pops may be mitigated through power titration even in high CFs.
Collapse
Affiliation(s)
- Junji Yamaguchi
- Department of Cardiovascular MedicineTokyo Medical and Dental University HospitalTokyoJapan
- Department of Clinical and Diagnostic Laboratory ScienceTokyo Medical and Dental UniversityTokyoJapan
| | - Masateru Takigawa
- Department of Cardiovascular MedicineTokyo Medical and Dental University HospitalTokyoJapan
| | - Masahiko Goya
- Department of Cardiovascular MedicineTokyo Medical and Dental University HospitalTokyoJapan
| | | | - Miho Negishi
- Department of Cardiovascular MedicineTokyo Medical and Dental University HospitalTokyoJapan
| | - Tasuku Yamamoto
- Department of Cardiovascular MedicineTokyo Medical and Dental University HospitalTokyoJapan
| | - Takashi Ikenouchi
- Department of Cardiovascular MedicineTokyo Medical and Dental University HospitalTokyoJapan
| | - Kentaro Goto
- Department of Cardiovascular MedicineTokyo Medical and Dental University HospitalTokyoJapan
| | - Takatoshi Shigeta
- Department of Cardiovascular MedicineTokyo Medical and Dental University HospitalTokyoJapan
| | - Iwanari Kawamura
- Department of Cardiovascular MedicineTokyo Medical and Dental University HospitalTokyoJapan
| | - Takuro Nishimura
- Department of Cardiovascular MedicineTokyo Medical and Dental University HospitalTokyoJapan
| | - Tomomasa Takamiya
- Department of Cardiovascular MedicineTokyo Medical and Dental University HospitalTokyoJapan
| | - Susumu Tao
- Department of Cardiovascular MedicineTokyo Medical and Dental University HospitalTokyoJapan
| | - Shinsuke Miyazaki
- Department of Cardiovascular MedicineTokyo Medical and Dental University HospitalTokyoJapan
| | - Tetsuo Sasano
- Department of Cardiovascular MedicineTokyo Medical and Dental University HospitalTokyoJapan
| |
Collapse
|
5
|
Yamaguchi J, Takigawa M, Goya M, Yamamoto T, Ikenouchi T, Iwakawa H, Negishi M, Goto K, Shigeta T, Nishimura T, Takamiya T, Tao S, Miyazaki S, Sasano T. Safety verification of a novel irrigation catheter with flexible tip of laser-cut kerfs and contact force sensor. Pacing Clin Electrophysiol 2023; 46:1536-1545. [PMID: 37957924 DOI: 10.1111/pace.14868] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/01/2023] [Revised: 10/27/2023] [Accepted: 10/29/2023] [Indexed: 11/15/2023]
Abstract
BACKGROUND AND AIMS The safety evaluation of TactiFlex, a novel contact-force sensing catheter with a flexible 4-mm tip irrigated through laser-cut kerfs, has been ongoing. This study aimed to verify the safety of this type of catheter. METHODS Study 1: Radiofrequency (RF) applications at a range of powers (30-50 W), contact forces (10-20 g), and durations (10-60 s) using perpendicular/parallel catheter orientation with half-normal (HNS) or normal saline irrigation were compared between TactiFlex (4-mm tip) and TactiCath (3.5-mm tip) with temperature-controlled mode in excised porcine hearts. Study 2: The relation between RF applications using TactiFlex and the incidence of steam-pops in the real clinical cases were examined. RESULTS Study-1: 576 RF lesions were examined. TactiFlex demonstrated a significantly lower risk of steam-pops (5[1.7%] vs. 59[20.5%], p < .0001). Compared to 3.5-mm-tip catheter (TactiCath), 4-mm-tip catheter (TactiFlex) produced smaller lesion volume at perpendicular (193[98-554]mm3 vs. 263[139-436]mm3 , p < .0001), but relatively similar lesion volume at parallel contact (243[105-443]mm3 vs. 278[180-440]mm3 , p = .06). HNS-irrigation tended to increase the lesion volume in both catheters and to increase the incidence of steam-pops with TactiCath, but not with TactiFlex. The cut-off value of %impedance-drop ( = absolute impedance-drop/initial impedance) of 20% predicted steam-pops with a sensitivity = 100% and specificity = 89.6% in TactiFlex. Study-2: 5496 RF applications in 84 patients (51AFs/8ATs/3AVNRTs/4AVRTs/17PVCs/4VTs) using TactiFlex were analyzed. Four steam-pops (0.07%) in three patients with pericardial effusion were observed (%impedance-drop = 24%/26%/29%/35%, respectively). The cut-off value of %impedance-drop = 20%, derived from ex-vivo study, showed sensitivity = 100% and specificity = 90.1% in detecting steam-pops. CONCLUSION TactiFlex reduced the risk of steam-pops than TactiCath. %impedance-drop ≤ 20% may be reasonable for safely use with a sufficient safety margin. For 4-mm-tip catheter, parallel-contact may be recommended for larger lesion creation.
Collapse
Affiliation(s)
- Junji Yamaguchi
- Department of Cardiovascular Medicine, Tokyo Medical and Dental University Hospital, Tokyo, Japan
- Department of Clinical and Diagnostic Laboratory Science, Tokyo Medical and Dental University, Tokyo, Japan
| | - Masateru Takigawa
- Department of Cardiovascular Medicine, Tokyo Medical and Dental University Hospital, Tokyo, Japan
| | - Masahiko Goya
- Department of Cardiovascular Medicine, Tokyo Medical and Dental University Hospital, Tokyo, Japan
| | - Tasuku Yamamoto
- Department of Cardiovascular Medicine, Tokyo Medical and Dental University Hospital, Tokyo, Japan
| | - Takashi Ikenouchi
- Department of Cardiovascular Medicine, Tokyo Medical and Dental University Hospital, Tokyo, Japan
| | - Hidehiro Iwakawa
- Department of Cardiovascular Medicine, Akita University Graduate School of Medicine, Akita, Japan
| | - Miho Negishi
- Department of Cardiovascular Medicine, Tokyo Medical and Dental University Hospital, Tokyo, Japan
| | - Kentaro Goto
- Department of Cardiovascular Medicine, Tokyo Medical and Dental University Hospital, Tokyo, Japan
| | - Takatoshi Shigeta
- Department of Cardiovascular Medicine, Tokyo Medical and Dental University Hospital, Tokyo, Japan
| | - Takuro Nishimura
- Department of Cardiovascular Medicine, Tokyo Medical and Dental University Hospital, Tokyo, Japan
| | - Tomomasa Takamiya
- Department of Cardiovascular Medicine, Tokyo Medical and Dental University Hospital, Tokyo, Japan
| | - Susumu Tao
- Department of Cardiovascular Medicine, Tokyo Medical and Dental University Hospital, Tokyo, Japan
| | - Shinsuke Miyazaki
- Department of Cardiovascular Medicine, Tokyo Medical and Dental University Hospital, Tokyo, Japan
| | - Tetsuo Sasano
- Department of Cardiovascular Medicine, Tokyo Medical and Dental University Hospital, Tokyo, Japan
| |
Collapse
|
6
|
Iwakawa H, Takigawa M, Yamaguchi J, Martin CA, Goya M, Yamamoto T, Amemiya M, Ikenouchi T, Negishi M, Kawamura I, Goto K, Shigeta T, Nishimura T, Takamiya T, Tao S, Miyazaki S, Watanabe H, Sasano T. Superiority of the Combination of Input and Output Parameters to the Single Parameter for Lesion Size Estimation. Circ J 2023; 87:1757-1764. [PMID: 37899173 DOI: 10.1253/circj.cj-23-0574] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 10/31/2023]
Abstract
BACKGROUND For lesion size prediction, each input parameter, including ablation energy (AE), and output parameter, such as impedance, is individually used. We hypothesize that using both parameters simultaneously may be more optimal. METHODS AND RESULTS Radiofrequency applications at a range of power (30-50 W), contact force (10 g and 20 g), duration (10-60 s), and catheter orientation with normal saline (NS)- or half-normal saline (HNS)-irrigation were performed in excised porcine hearts. The correlations, with lesion size of AE, absolute impedance drop (∆Imp-drop), relative impedance drop (%Imp-drop), and AE*%Imp-drop were examined. Lesion size was analyzed in 283 of 288 lesions (NS-irrigation, n=142; HNS-irrigation, n=141) without steam pops. AE*%Imp-drop consistently showed the strongest correlations with lesion maximum depth (NS-irrigation, ρ=0.91; HNS-irrigation, ρ=0.94), surface area (NS-irrigation, ρ=0.87; HNS-irrigation, ρ=0.86), and volume (NS-irrigation, ρ=0.94; HNS-irrigation, ρ=0.94) compared with the other parameters. Moreover, compared with AE alone, AE*%Imp-drop significantly improved the strength of correlation with lesion maximum depth (AE vs. AE*%Imp-drop, ρ=0.83 vs. 0.91, P<0.01), surface area (ρ=0.73 vs. 0.87, P<0.01), and volume (ρ=0.84 vs. 0.94, P<0.01) with NS-irrigation. This tendency was also observed with HNS-irrigation. Parallel catheter orientation showed a better correlation with lesion depth and volume using ∆Imp-drop, %Imp-drop, and AE*%Imp-drop than perpendicular orientation. CONCLUSIONS The combination of input and output parameters is more optimal than each single parameter for lesion prediction.
Collapse
Affiliation(s)
- Hidehiro Iwakawa
- Department of Cardiovascular Medicine, Tokyo Medical and Dental University
- Department of Cardiovascular Medicine, Akita University Graduate School of Medicine
| | - Masateru Takigawa
- Department of Cardiovascular Medicine, Tokyo Medical and Dental University
| | - Junji Yamaguchi
- Department of Cardiovascular Medicine, Tokyo Medical and Dental University
| | | | - Masahiko Goya
- Department of Cardiovascular Medicine, Tokyo Medical and Dental University
| | - Tasuku Yamamoto
- Department of Cardiovascular Medicine, Tokyo Medical and Dental University
| | - Miki Amemiya
- Department of Cardiovascular Medicine, Tokyo Medical and Dental University
| | - Takashi Ikenouchi
- Department of Cardiovascular Medicine, Tokyo Medical and Dental University
| | - Miho Negishi
- Department of Cardiovascular Medicine, Tokyo Medical and Dental University
| | - Iwanari Kawamura
- Department of Cardiovascular Medicine, Tokyo Medical and Dental University
| | - Kentaro Goto
- Department of Cardiovascular Medicine, Tokyo Medical and Dental University
| | - Takatoshi Shigeta
- Department of Cardiovascular Medicine, Tokyo Medical and Dental University
| | - Takuro Nishimura
- Department of Cardiovascular Medicine, Tokyo Medical and Dental University
| | - Tomomasa Takamiya
- Department of Cardiovascular Medicine, Tokyo Medical and Dental University
| | - Susumu Tao
- Department of Cardiovascular Medicine, Tokyo Medical and Dental University
| | - Shinsuke Miyazaki
- Department of Cardiovascular Medicine, Tokyo Medical and Dental University
| | - Hiroyuki Watanabe
- Department of Cardiovascular Medicine, Akita University Graduate School of Medicine
| | - Tetsuo Sasano
- Department of Cardiovascular Medicine, Tokyo Medical and Dental University
| |
Collapse
|
7
|
Bahlke F, Wachter A, Erhard N, Englert F, Krafft H, Popa M, Risse E, Kottmaier M, Telishevska M, Lengauer S, Lennerz C, Reents T, Hessling G, Deisenhofer I, Bourier F. The influence of electrode-tissue-coverage on RF lesion formation and local impedance: Insights from an ex vivo model. Pacing Clin Electrophysiol 2023; 46:1170-1181. [PMID: 37616376 DOI: 10.1111/pace.14807] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/02/2023] [Revised: 07/16/2023] [Accepted: 08/11/2023] [Indexed: 08/26/2023]
Abstract
BACKGROUND The influence of power, duration and contact force (CF) on radiofrequency (RF) lesion formation is well known, whereas data on local impedance (LI) and electrode-tissue-coverage (ETC) is scarce. The objective was to investigate their effect on lesion formation in an ex vivo model. METHODS AND RESULTS An ex vivo model was developed utilizing cross-sections of porcine heart preparations and a force-sensing, LI-measuring catheter. N = 72 lesion were created systematically varying ETC (minor/full), CF (1-5 g, 10-15 g, 20-25 g) and power (20 W, 30 W, 40 W, 50 W). In minor ETC, the distal tip of the catheter was in electric contact with the tissue, in full ETC the whole catheter tip was embedded within the tissue. Lesion size and all parameters were measured once per second (n = 3320). LI correlated strongly with lesion depth (r = -0.742 for ΔLI; r = 0.781 for %LI-drop). Lesions in full ETC were significantly wider and deeper compared to minor ETC (p < .001) and steam pops were more likely. Baseline LI, ΔLI, and %LI-drop were significantly higher in full ETC (p < .001). In lesions resulting in steam pops, baseline LI, and ΔLI were significantly higher. The influence of CF on lesion size was higher in minor ETC than in full ETC. CONCLUSIONS ETC is a main determinant of lesion size and occurrence of steam pops. Baseline LI and LI-drop are useful surrogate parameters for real-time assessment of ETC and ΔLI correlates strongly with lesion size.
Collapse
Affiliation(s)
- Fabian Bahlke
- Department of Electrophysiology, German Heart Center Munich, Technical University of Munich (TUM), Munich, Germany
| | - Andreas Wachter
- Department of Electrophysiology, German Heart Center Munich, Technical University of Munich (TUM), Munich, Germany
| | - Nico Erhard
- Department of Electrophysiology, German Heart Center Munich, Technical University of Munich (TUM), Munich, Germany
| | - Florian Englert
- Department of Electrophysiology, German Heart Center Munich, Technical University of Munich (TUM), Munich, Germany
| | - Hannah Krafft
- Department of Electrophysiology, German Heart Center Munich, Technical University of Munich (TUM), Munich, Germany
| | - Miruna Popa
- Department of Electrophysiology, German Heart Center Munich, Technical University of Munich (TUM), Munich, Germany
| | - Elena Risse
- Department of Electrophysiology, German Heart Center Munich, Technical University of Munich (TUM), Munich, Germany
| | - Marc Kottmaier
- Department of Electrophysiology, German Heart Center Munich, Technical University of Munich (TUM), Munich, Germany
| | - Marta Telishevska
- Department of Electrophysiology, German Heart Center Munich, Technical University of Munich (TUM), Munich, Germany
| | - Sarah Lengauer
- Department of Electrophysiology, German Heart Center Munich, Technical University of Munich (TUM), Munich, Germany
| | - Carsten Lennerz
- Department of Electrophysiology, German Heart Center Munich, Technical University of Munich (TUM), Munich, Germany
| | - Tilko Reents
- Department of Electrophysiology, German Heart Center Munich, Technical University of Munich (TUM), Munich, Germany
| | - Gabriele Hessling
- Department of Electrophysiology, German Heart Center Munich, Technical University of Munich (TUM), Munich, Germany
| | - Isabel Deisenhofer
- Department of Electrophysiology, German Heart Center Munich, Technical University of Munich (TUM), Munich, Germany
| | - Felix Bourier
- Department of Electrophysiology, German Heart Center Munich, Technical University of Munich (TUM), Munich, Germany
| |
Collapse
|
8
|
Takigawa M, Yamamoto T, Amemiya M, Martin CA, Ikenouchi T, Yamaguchi J, Negishi M, Goto K, Shigeta T, Nishimura T, Tao S, Miyazaki S, Goya M, Sasano T. Impact of baseline pool impedance on lesion metrics and steam pops in catheter ablation. J Cardiovasc Electrophysiol 2023; 34:1671-1680. [PMID: 37337433 DOI: 10.1111/jce.15964] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/28/2023] [Revised: 05/19/2023] [Accepted: 05/29/2023] [Indexed: 06/21/2023]
Abstract
INTRODUCTION Little is known about the impact of blood-pool local impedance (LI) on lesion characteristics and the incidence of steam pops. METHODS Radiofrequency applications at a range of powers (30, 40, and 50 W), contact forces (CF) (5, 15, and 25 g), and durations (15, 30, 45, and 120 s) using perpendicular/parallel catheter orientation were performed in 40 excised porcine preparations, using a catheter capable of monitoring LI (StablePoint©, Boston Scientific). To simulate the variability in blood-pool impedance, the saline-pool LI was modulated by calibrating saline concentrations. Lesion characteristics were compared under three values of saline-pool LI: 120, 160, and 200 Ω. RESULTS Of 648 lesions created, steam pops occurred in 175 (27.0%). When power, CF, time, and catheter orientation were adjusted, ablation at a saline-pool impedance of 160 or 200 Ω more than doubled the risk of steam pops compared with a saline-pool impedance of 120 Ω (Odds ratio = 2.31; p = .0002). Lesions in a saline-pool impedance of 120 Ω were significantly larger in surface area (50 [38-62], 45 [34-56], and 41 [34-60] mm2 for 120, 160, and 200 Ω, p < .05), but shallower in depth (4.0 [3-5], 4.4 [3.2-5.3], and 4.5 [3.8-5.5] mmfor 120, 160, and 200 Ω, respectively, p < .05) compared with the other two settings. The correlation between the absolute LI-drop and lesion size weakened as the saline-pool LI became higher (e.g., 120 Ω group (r2 = .30, r2 = .18, and r2 = .16, respectively for 120, 160, and 200 Ω), but the usage of %LI-drop (= absolute LI-drop/initial LI) instead of absolute LI-drop may minimize this effect. CONCLUSIONS In an experimental model, baseline saline-pool impedance significantly affects the lesion metrics and the risk of steam pops.
Collapse
Affiliation(s)
- Masateru Takigawa
- Department of Cardiovascular Medicine, Heart Rhythm Center, Tokyo Medical and Dental University, Tokyo, Japan
| | - Tasuku Yamamoto
- Department of Cardiovascular Medicine, Heart Rhythm Center, Tokyo Medical and Dental University, Tokyo, Japan
| | - Miki Amemiya
- Department of Cardiovascular Medicine, Heart Rhythm Center, Tokyo Medical and Dental University, Tokyo, Japan
| | - Claire A Martin
- Royal Papworth Hospital, Cambridge University, Cambridge, UK
| | - Takashi Ikenouchi
- Department of Cardiovascular Medicine, Heart Rhythm Center, Tokyo Medical and Dental University, Tokyo, Japan
| | - Junji Yamaguchi
- Department of Cardiovascular Medicine, Heart Rhythm Center, Tokyo Medical and Dental University, Tokyo, Japan
| | - Miho Negishi
- Department of Cardiovascular Medicine, Heart Rhythm Center, Tokyo Medical and Dental University, Tokyo, Japan
| | - Kentaro Goto
- Department of Cardiovascular Medicine, Heart Rhythm Center, Tokyo Medical and Dental University, Tokyo, Japan
| | - Takatoshi Shigeta
- Department of Cardiovascular Medicine, Heart Rhythm Center, Tokyo Medical and Dental University, Tokyo, Japan
| | - Takuro Nishimura
- Department of Cardiovascular Medicine, Heart Rhythm Center, Tokyo Medical and Dental University, Tokyo, Japan
| | - Susumu Tao
- Department of Cardiovascular Medicine, Heart Rhythm Center, Tokyo Medical and Dental University, Tokyo, Japan
| | - Shinsuke Miyazaki
- Department of Cardiovascular Medicine, Heart Rhythm Center, Tokyo Medical and Dental University, Tokyo, Japan
| | - Masahiko Goya
- Department of Cardiovascular Medicine, Heart Rhythm Center, Tokyo Medical and Dental University, Tokyo, Japan
| | - Tetsuo Sasano
- Department of Cardiovascular Medicine, Heart Rhythm Center, Tokyo Medical and Dental University, Tokyo, Japan
| |
Collapse
|
9
|
Saitoh O, Kasai T, Fuse K, Chinushi M. Distribution of excitation recoverable myocardium after radiofrequency ablation and its relation to energy application time and irrigation. J Cardiovasc Electrophysiol 2023; 34:928-941. [PMID: 36852910 DOI: 10.1111/jce.15873] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/02/2022] [Revised: 01/31/2023] [Accepted: 02/20/2023] [Indexed: 03/01/2023]
Abstract
INTRODUCTION Radiofrequency (RF) catheter ablation induces excitation recoverable myocardium around durable core lesions, and its distribution may be different depending on energy delivery methods. METHODS AND RESULTS In coronary perfusing porcine hearts, pacing threshold through the ventricle was measured using eight-pole (1-mm distance) needle electrodes vertically inserted into myocardium before, within 3 min after and 40 min after 40 W ablation with 10-g catheter contact (Group 1: irrigation catheter for 15 s, Group 2: irrigation catheter for 40 s, Group 3: nonirrigation catheter for 15 s, Group 4: nonirrigation catheter for 40 s). Ablation was accomplished in all 12 ablations in Groups 1-3 whereas in 8/12 ablations in Group 4 because of high-temperature rise. Within 3 min after ablation, 10.0 V pacing uncaptured electrodes were distributed from the surface to inside the myocardium, and its depth was deeper in 40 s than in 15 s ablation. 40 min after ablation, excitation recovery at one or more electrodes below the durable lesion was observed in all Groups. Excitation recovery electrodes were also observed on the surface in Group 1 but not the other Groups. Accordingly, the number of excitation-recovered electrodes were larger in Group 1 than the other Groups. CONCLUSIONS Regardless of the ablation methods, excitation recoverable myocardium was present around 1.0 mm below the durable lesions. Lesions created by short application time using an irrigation catheter may have included large excitation recoverable myocardium soon after ablation because of the presence of reversible myocardium on well-irrigated myocardial surfaces.
Collapse
Affiliation(s)
- Osamu Saitoh
- Cardiovascular Research of Graduate School of Health Sciences, Niigata University School of Medicine, Niigata, Japan
| | - Takumi Kasai
- Cardiovascular Research of Graduate School of Health Sciences, Niigata University School of Medicine, Niigata, Japan
| | - Kyogo Fuse
- Cardiovascular Research of Graduate School of Health Sciences, Niigata University School of Medicine, Niigata, Japan
| | - Masaomi Chinushi
- Cardiovascular Research of Graduate School of Health Sciences, Niigata University School of Medicine, Niigata, Japan
| |
Collapse
|
10
|
Impact of tip design and thermocouple location on the efficacy and safety of radiofrequency application. J Interv Card Electrophysiol 2022; 66:885-896. [PMID: 35451737 DOI: 10.1007/s10840-022-01219-8] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/04/2021] [Accepted: 04/06/2022] [Indexed: 10/18/2022]
Abstract
BACKGROUND The FlexAbility™ SE catheter has a laser-cut 8Fr 4-mm flexible tip irrigated through laser-cut kerfs with a thermocouple 0.3 mm from the distal end. The TactiCath™ SE catheter has an 8Fr 3.5-mm tip and 6-irrigation port with a thermocouple 2.67 mm proximal to the tip. We investigated the impact of these differences on the efficacy and safety of radiofrequency (RF) applications. METHODS RF applications at a range of powers (20 W, 30 W, and 40 W), contact forces (5 g, 15 g, and 25 g), and durations (10-60 s) using perpendicular/parallel catheter orientation were performed in excised porcine hearts. Lesion characteristics and incidence of steam pops were compared. RESULTS A total of 540 lesions were examined. The FlexAbility™ SE catheter produced smaller lesion depths (4.0 mm vs. 4.4 mm, p = 0.014 at 20 W; 4.6 mm vs. 5.6 mm, p = 0.015 at 30 W), surface areas (22.7mm2 vs. 29.2mm2 at 20 W, p = 0.005; 23.2mm2 vs. 28.7mm2, p = 0.009 at 30 W), and volumes (126.1mm3 vs. 175.1mm3, p = 0.018 at 20 W; 183.2mm3 vs. 304.3mm3, p = 0.002 at 30 W) with perpendicular catheter placement. However, no differences were observed with parallel catheter placement. Steam-pops were significantly less frequently observed with the FlexAbility™ SE catheter (4% vs. 22%, p < 0.001) irrespective of catheter direction to the tissue. Multivariate analysis showed that use of the TactiCath™ SE catheter, power ≥ 40 W, contact force ≥ 25 g, RF duration > 30 s, parallel angle, and impedance drop ≥ 20Ω were significantly associated with occurrence of steam-pops. CONCLUSIONS The FlexAbility™ SE catheter reduced the risk of steam-pops but produced smaller lesions with perpendicular catheter placement compared to the TactiCath™ SE catheter.
Collapse
|
11
|
Comparison of two catheters measuring local impedance: local impedance variation vs lesion characteristics and steam pops. J Interv Card Electrophysiol 2022; 65:419-428. [PMID: 35438394 DOI: 10.1007/s10840-022-01214-z] [Citation(s) in RCA: 9] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/03/2022] [Accepted: 03/31/2022] [Indexed: 10/18/2022]
Abstract
PURPOSE The size of the distal electrode and the method of measuring local impedance (LI) are different between the IntellaNav MiFi-OI™ (MiFi-OI) and IntellaNav STABLE POINT™ (SP) catheters. We investigated the impact of these differences on LI, efficacy, and safety of radiofrequency (RF) applications. METHODS RF applications at a range of powers (30 W, 40 W, and 50 W), contact forces (10 g and 20 g), and durations (10-120 s) were performed in excised porcine hearts (N = 48). LI variation was defined by δLI-drop (= initial LI - post-RF LI) and %LI-drop (= δLI-drop/initial LI) × 100, and the relationship between lesion characteristics and LI variation was compared. RESULTS A total of 576 lesions were examined. Although absolute δLI-drop during RF applications was significantly larger for the SP than MiFi-OI catheter (47[31-65]ohm for SP vs 37[24-51]ohm for MiFi-OI, p < 0.0001), %LI-drop was similar (23.3 [15.5-30.6]% in SP vs 24.9[17.3-32.5]% in MiFi-OI, p = 0.10). Although lesions produced by both catheters were similarly correlated with LI variation, the SP catheter produced generally larger lesions (depth; 5.0 [3.7-6.1]mm vs 4.7 [3.3-6.0]mm, p = 0.06; surface areas, 46.9 [36.8-58.8]mm2 vs 44.7 [34.3-55.5]mm2, p = 0.02; volume, 321 [165-533]mm3 vs 265[141-471]mm3, p = 0.02). Steam pops were similarly observed with both catheters. In both catheters, %LI-drop was superior to δLI-drop in correlation to lesion size (p < 0.0001) and in predicting steam pops (p < 0.01). CONCLUSIONS Although no difference in safety profile is observed between MiFi-OI and SP catheters, the SP catheter produces larger lesions. %LI-drop is superior to δLI-drop in correlation to lesion size and in predicting steam pops as well as in normalizing the difference between catheters.
Collapse
|
12
|
Masnok K, Watanabe N. Catheter contact area strongly correlates with lesion area in radiofrequency cardiac ablation: an ex vivo porcine heart study. J Interv Card Electrophysiol 2022; 63:561-572. [PMID: 34499311 PMCID: PMC9151538 DOI: 10.1007/s10840-021-01054-3] [Citation(s) in RCA: 14] [Impact Index Per Article: 4.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/06/2021] [Accepted: 08/18/2021] [Indexed: 11/29/2022]
Abstract
PURPOSE Our previous study confirmed that not only force but also the catheter contact angle substantially impacted the contact area and its morphology. Therefore, in this study, we aimed to further investigate the relationship between the catheter contact area and the dimensions of the ablation lesion area as a function of catheter contact angle and force in radiofrequency catheter ablation. METHODS The radiofrequency catheter ablation test was performed for 5 contact angles and 8 contact forces at a fixed ablation time of 30 s. The initial impedance was 92.5 ± 2.5 Ω, the temperature during ablation was 30 °C, and the power was 30 W. The irrigation rate during ablation was set to 17 mL/min. Each experiment was repeated 6 times. RESULTS The catheter contact area showed a strong correlation with the ablation lesion area (r = 0.8507). When the contact area was increased, the lesion area also increased linearly in a monotonic manner. The relationships between catheter contact force and ablation lesion area and between catheter contact force and ablation lesion depth are logarithmic functions in which increased contact force was associated with increased lesion area and depth. The catheter contact angle is also an important determinant of the lesion area. The lesion area progressively increased when the contact angle was decreased. In contrast, the lesion depth progressively increased when the contact angle was increased. CONCLUSIONS The catheter contact area was strongly correlated with the ablation lesion area. Additionally, catheter contact force and contact angle significantly impacted the dimensions of the lesion in radiofrequency catheter ablation procedures.
Collapse
Affiliation(s)
- Kriengsak Masnok
- Biofluid Science and Engineering Laboratory, Functional Control Systems, Graduate School of Engineering and Science, Shibaura Institute of Technology, Room-102, 6th Building, Omiya-Campus, 307 Fukasaku, Minuma-Ku, Saitama-City, Saitama, 337-8570, Japan
| | - Nobuo Watanabe
- Biofluid Science and Engineering Laboratory, Functional Control Systems, Graduate School of Engineering and Science, Shibaura Institute of Technology, Room-102, 6th Building, Omiya-Campus, 307 Fukasaku, Minuma-Ku, Saitama-City, Saitama, 337-8570, Japan.
- Department of Bio-Science and Engineering, College of Systems Engineering and Science, Shibaura Institute of Technology, Saitama, Japan.
| |
Collapse
|
13
|
Chu GS, Calvert P, Futyma P, Ding WY, Snowdon R, Gupta D. Local impedance for the optimization of radiofrequency lesion delivery: A review of bench and clinical data. J Cardiovasc Electrophysiol 2021; 33:389-400. [PMID: 34921465 DOI: 10.1111/jce.15335] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/25/2021] [Revised: 11/11/2021] [Accepted: 12/05/2021] [Indexed: 12/25/2022]
Abstract
INTRODUCTION Radiofrequency catheter ablation is a cornerstone of treatment for many cardiac arrhythmias. Progression in three-dimensional mapping and contact-force sensing technologies have improved our capability to achieve success, but challenges still remain. METHODS In this article, we discuss the importance of overall circuit impedance in radiofrequency lesion formation. This is followed by a review of the literature regarding recently developed "local impedance" technology and its current and future potential applications and limitations, in the context of established surrogate markers currently used to infer effective ablation. RESULTS We discuss the role of local impedance in assessing myocardial substrate, as well as its role in clinical studies of ablation. We also discuss safety considerations, limitations and ongoing research. CONCLUSION Local impedance is a novel tool which has the potential to tailor ablation in a manner distinct from other established metrics.
Collapse
Affiliation(s)
- Gavin S Chu
- Department of Cardiology, Liverpool Heart and Chest Hospital NHS Foundation Trust, Liverpool, UK.,Department of Cardiovascular Sciences, University of Leicester, Leicester, UK
| | - Peter Calvert
- Department of Cardiology, Liverpool Heart and Chest Hospital NHS Foundation Trust, Liverpool, UK.,Research Unit, Liverpool Centre for Cardiovascular Science, University of Liverpool, Liverpool, UK
| | - Piotr Futyma
- Department of Cardiology, Medical College of the University of Rzeszów, St. Joseph's Heart Rhythm Center, Rzeszów, Poland, Rzeszów, Poland
| | - Wern Yew Ding
- Department of Cardiology, Liverpool Heart and Chest Hospital NHS Foundation Trust, Liverpool, UK.,Research Unit, Liverpool Centre for Cardiovascular Science, University of Liverpool, Liverpool, UK
| | - Richard Snowdon
- Department of Cardiology, Liverpool Heart and Chest Hospital NHS Foundation Trust, Liverpool, UK
| | - Dhiraj Gupta
- Department of Cardiology, Liverpool Heart and Chest Hospital NHS Foundation Trust, Liverpool, UK.,Research Unit, Liverpool Centre for Cardiovascular Science, University of Liverpool, Liverpool, UK
| |
Collapse
|