1
|
Kishihara J, Fukaya H, Yamashita K, Ono M, Igawa W, Saito J, Takano M, Ishizue N, Nakamura H, Matsuura G, Oikawa J. Voltage-guided pulmonary vein isolation for atrial fibrillation. Heart Rhythm 2025; 22:1142-1149. [PMID: 39181488 DOI: 10.1016/j.hrthm.2024.08.041] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/19/2024] [Revised: 08/04/2024] [Accepted: 08/19/2024] [Indexed: 08/27/2024]
Abstract
BACKGROUND Bipolar voltage amplitude is capable of helping determine the ideal lesion size index (LSI) setting during radiofrequency ablation for atrial fibrillation (AF). OBJECTIVE We aimed to determine whether voltage-guided pulmonary vein isolation (PVI) is noninferior to conventional LSI-guided PVI in patients with nonvalvular AF. METHODS This was a multicenter randomized trial conducted during a period of 12 months. The primary efficacy end points of the study were AF recurrence, atrial flutter, and atrial tachycardia, and the noninferiority margin was set at a hazard ratio of 1.4. The primary safety end point was a composite of procedure-related complications. RESULTS A total of 370 patients underwent randomization; 189 and 181 were assigned to the voltage (underwent voltage-guided PVI) and control (underwent conventional LSI-guided PVI) groups, respectively. The primary efficacy end point occurred in 22 patients (12.0%) in the voltage group and 23 patients (12.9%) in the control group (1-year Kaplan-Meier event-free rate estimates, 88.0% and 87.1%, respectively; hazard ratio, 1.00; 95% confidence interval, 0.80-1.25). The primary safety end points were 4.8% in the voltage group and 6.6% in the control group (P = .2791). PVI time was significantly shorter in the voltage group (35.7 ± 14.5 minutes vs 39.7 ± 14.7 minutes; P < .001). CONCLUSION Voltage-guided PVI was noninferior to conventional LSI-guided PVI with respect to efficacy in the treatment of patients with AF, and its use significantly reduced procedure time. UMIN Clinical Trials Registry: UMIN000042325.
Collapse
Affiliation(s)
- Jun Kishihara
- Department of Cardiovascular Medicine, Kitasato University School of Medicine, Sagamihara, Japan.
| | - Hidehira Fukaya
- Department of Cardiovascular Medicine, Kitasato University School of Medicine, Sagamihara, Japan
| | - Kennosuke Yamashita
- Heart Rhythm Center, Department of Cardiovascular Medicine, Sendai Kosei Hospital, Miyagi, Japan
| | - Morio Ono
- Department of Cardiovascular Medicine, Showa University Northern Yokohama Hospital, Yokohama, Japan
| | - Wataru Igawa
- Department of Cardiovascular Medicine, Showa University Northern Yokohama Hospital, Yokohama, Japan
| | - Junpei Saito
- Department of Cardiovascular Medicine, Showa University Northern Yokohama Hospital, Yokohama, Japan
| | - Makoto Takano
- Division of Cardiology, Department of Internal Medicine, St Marianna University School of Medicine, Kawasaki, Japan
| | - Naruya Ishizue
- Department of Cardiovascular Medicine, Kitasato University School of Medicine, Sagamihara, Japan
| | - Hironori Nakamura
- Department of Cardiovascular Medicine, Kitasato University School of Medicine, Sagamihara, Japan
| | - Gen Matsuura
- Department of Cardiovascular Medicine, Kitasato University School of Medicine, Sagamihara, Japan
| | - Jun Oikawa
- Department of Kitasato Clinical Research Center, Kitasato University School of Medicine, Sagamihara, Japan
| |
Collapse
|
2
|
Buschmann E, Van Steenkiste G, Vernemmen I, Demeyere M, Schauvliege S, Decloedt A, van Loon G. Lesion size index-guided radiofrequency catheter ablation using an impedance-based three-dimensional mapping system to treat sustained atrial tachycardia in a horse. Equine Vet J 2024. [PMID: 39434506 DOI: 10.1111/evj.14424] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/27/2024] [Accepted: 09/19/2024] [Indexed: 10/23/2024]
Abstract
Sustained atrial tachycardia at an atrial rate of 191/min on the surface ECG was detected in a 6-year-old Warmblood mare. The vectorcardiogram obtained from a 12-lead ECG suggested a caudo-dorsal right atrial origin of the arrhythmia. Impedance-based three-dimensional electro-anatomical mapping, using the EnSite™ Precision Cardiac Mapping System revealed a clockwise macro-reentry around a line of conduction block in the caudomedial right atrium. Ten radiofrequency applications were applied to isolate the caudal vena cava myocardial sleeves at a power of 35 W and mean contact force of 14 ± 3 g until a lesion size index of 6 was reached. Sinus rhythm was restored at the first energy application. Successful isolation was confirmed by demonstrating entrance and exit block. Holter monitoring 5 days post-ablation revealed no abnormalities. To date, 9 months after treatment, no recurrence has been observed. The use of lesion size index-guided ablation and isolation of the arrhythmogenic substrate in the caudal vena cava may minimise the risk of recurrence.
Collapse
Affiliation(s)
- Eva Buschmann
- Equine Cardioteam Ghent, Department of Internal Medicine, Reproduction and Population Medicine, Faculty of Veterinary Medicine, Ghent University, Merelbeke, Belgium
| | - Glenn Van Steenkiste
- Equine Cardioteam Ghent, Department of Internal Medicine, Reproduction and Population Medicine, Faculty of Veterinary Medicine, Ghent University, Merelbeke, Belgium
| | - Ingrid Vernemmen
- Equine Cardioteam Ghent, Department of Internal Medicine, Reproduction and Population Medicine, Faculty of Veterinary Medicine, Ghent University, Merelbeke, Belgium
| | - Marie Demeyere
- Equine Cardioteam Ghent, Department of Internal Medicine, Reproduction and Population Medicine, Faculty of Veterinary Medicine, Ghent University, Merelbeke, Belgium
| | - Stijn Schauvliege
- Department of Large Animal Surgery, Anesthesia and Orthopedics, Ghent University, Merelbeke, Belgium
| | - Annelies Decloedt
- Equine Cardioteam Ghent, Department of Internal Medicine, Reproduction and Population Medicine, Faculty of Veterinary Medicine, Ghent University, Merelbeke, Belgium
| | - Gunther van Loon
- Equine Cardioteam Ghent, Department of Internal Medicine, Reproduction and Population Medicine, Faculty of Veterinary Medicine, Ghent University, Merelbeke, Belgium
| |
Collapse
|
3
|
Narita M, Higuchi S, Kawano D, Sasaki W, Matsumoto K, Tanaka N, Mori H, Tsutsui K, Ikeda Y, Arai T, Nakano S, Kato R, Matsumoto K. Does the same lesion index mean the same efficacy and safety profile: influence of the differential power, time, and contact force on the lesion size and steam pops under the same lesion index. J Interv Card Electrophysiol 2024; 67:147-155. [PMID: 37311981 DOI: 10.1007/s10840-023-01583-z] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/20/2023] [Accepted: 05/28/2023] [Indexed: 06/15/2023]
Abstract
BACKGROUND The lesion index (LSI) helps predict the lesion size and is widely used in ablation of various types of arrhythmias. However, the influence of the ablation settings on the lesion formation and incidence of steam pops under the same LSI value remains unclear. METHODS Using a contact force (CF) sensing catheter (TactiCath™) in an ex vivo swine left ventricle model, RF lesions were created with a combination of various power steps (30 W, 40 W, 50 W) and CFs (10 g, 20 g, 30 g, 40 g, 50 g) under the same LSI values (5.2 and 7.0). The correlation between the lesion formation and ablation parameters was evaluated. RESULTS Ninety RF lesions were created under a target LSI value of 5.2, and eighty-four were developed under a target LSI value of 7.0. In the LSI 5.2 group, the resultant lesion size widely varied according to the ablation power, and a multiple regression analysis indicated that the ablation energy delivered was the best predictor of the lesion formation. To create a lesion depth > 4 mm, an ablation energy of 393 J is the best cutoff value, suggesting a possibility that ablation energy may be used as a supplemental marker that better monitors the progress of the lesion formation in an LSI 5.2 ablation. In contrast, such inconsistency was not obvious in the LSI 7.0 group. Compared with 30 W, the 50-W ablation exhibited a higher incidence of steam pops in both the LSI 5.2 and 7.0 groups. CONCLUSIONS The LSI-lesion size relationship was not necessarily consistent, especially for an LSI of 5.2. To avoid any unintentional, weak ablation, the ablation energy may be a useful supportive parameter (393 J as a cutoff value for a 4-mm depth) during ablation with an LSI around 5.2. Thanks to a prolonged ablation time, the LSI-lesion size relationship is consistent for an LSI of 7.0. However, it is accompanied by a high incidence of steam pops. Care should be given to the ablation settings even when the same LSI value is used.
Collapse
Affiliation(s)
- Masataka Narita
- Department of Cardiology, Saitama Medical University International Medical Center, Yamane, Hidaka, Saitama, 1397-1, Japan
| | - Syunta Higuchi
- Department of Medical Engineer, Saitama Medical University International Medical Center, Hidaka, Japan
| | - Daisuke Kawano
- Department of Cardiology, Saitama Medical University International Medical Center, Yamane, Hidaka, Saitama, 1397-1, Japan
| | - Wataru Sasaki
- Department of Cardiology, Saitama Medical University International Medical Center, Yamane, Hidaka, Saitama, 1397-1, Japan
| | - Kazuhisa Matsumoto
- Department of Cardiology, Saitama Medical University International Medical Center, Yamane, Hidaka, Saitama, 1397-1, Japan
| | - Naomichi Tanaka
- Department of Cardiology, Saitama Medical University International Medical Center, Yamane, Hidaka, Saitama, 1397-1, Japan
| | - Hitoshi Mori
- Department of Cardiology, Saitama Medical University International Medical Center, Yamane, Hidaka, Saitama, 1397-1, Japan.
| | - Kenta Tsutsui
- Department of Cardiology, Saitama Medical University International Medical Center, Yamane, Hidaka, Saitama, 1397-1, Japan
| | - Yoshifumi Ikeda
- Department of Cardiology, Saitama Medical University International Medical Center, Yamane, Hidaka, Saitama, 1397-1, Japan
| | - Takahide Arai
- Department of Cardiology, Saitama Medical University International Medical Center, Yamane, Hidaka, Saitama, 1397-1, Japan
| | - Shintaro Nakano
- Department of Cardiology, Saitama Medical University International Medical Center, Yamane, Hidaka, Saitama, 1397-1, Japan
| | - Ritsushi Kato
- Department of Cardiology, Saitama Medical University International Medical Center, Yamane, Hidaka, Saitama, 1397-1, Japan
| | - Kazuo Matsumoto
- Department of Cardiology, Saitama Medical University International Medical Center, Yamane, Hidaka, Saitama, 1397-1, Japan
| |
Collapse
|
4
|
Sousa PA, Barra S, Adão L, Primo J, Khoueiry Z, Puga L, Lebreiro A, Fonseca P, Lagrange P, Gonçalves L. Assessment of the Need of a Waiting Period after Pulmonary Vein Isolation with the Ablation Index Software. J Cardiovasc Electrophysiol 2022; 33:1725-1733. [PMID: 35637604 DOI: 10.1111/jce.15568] [Citation(s) in RCA: 9] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/30/2022] [Revised: 04/20/2022] [Accepted: 05/07/2022] [Indexed: 11/29/2022]
Abstract
PURPOSE Since the widespread availability of contact-force sensing catheters, the need of a waiting period after pulmonary vein isolation (PVI) has not been reassessed. We aim to evaluate whether a waiting period is still necessary after PVI guided by the Ablation Index (AI). METHODS Prospective, multicenter, randomized study of consecutive patients referred for paroxysmal atrial fibrillation (AF) ablation from May 2019 to February 2020. Patients were randomized in a 1:1 ratio to PVI with versus without a waiting period of 20 minutes. Acute pulmonary vein (PV) reconnection after adenosine challenge was the primary endpoint. A per-protocol analysis was designed to determine whether a strategy of dismissing the waiting period after PVI was noninferior to waiting 20minutes for identifying acute PV reconnection. PVI was guided by tailored AI values and an inter-lesion distance ≤6mm. RESULTS During the enrollment period, 167 patients (56% males, mean age of 57±14 years) fulfilled the study inclusion criteria - 84 patients (308 PV) in the waiting period group (group A) and 83 patients (314 PV) in the group without a waiting period (group B). Acute PV reconnection was identified in 3.8% (95% CI, 1.7% to 5.9%) of PVs in the study group B compared to 2.9% (95% CI, 1.0% to 4.8%) of PVs in the group A (p=0.002 for non-inferiority). At 1-year follow-up there was no significant difference in arrhythmia recurrence between groups (9.5% in group A vs. 9.6% in group B, HR 1.03 [95% CI, 0.39-2.73], p=0.98). CONCLUSIONS In paroxysmal AF patients submitted to ablation, a tailored PVI guided by the Ablation Index rendered a 20-minute waiting period unnecessary. This article is protected by copyright. All rights reserved.
Collapse
Affiliation(s)
- Pedro A Sousa
- Pacing & Electrophysiology Unit, Cardiology Department, Coimbra's Hospital and University Center, Coimbra, Portugal
| | - Sérgio Barra
- Cardiology Department, Hospital da Luz Arrábida, V. N. Gaia, Portugal
| | - Luís Adão
- Cardiology Department, University Hospital Center of São João, Porto, Portugal
| | - João Primo
- Cardiology Department, Vila Nova de Gaia & Espinho Hospital Center, V. N. Gaia, Portugal
| | - Ziad Khoueiry
- Cardiology Department, Clinique Saint Pierre, Perpignan, France
| | - Luís Puga
- Pacing & Electrophysiology Unit, Cardiology Department, Coimbra's Hospital and University Center, Coimbra, Portugal
| | - Ana Lebreiro
- Cardiology Department, University Hospital Center of São João, Porto, Portugal
| | - Paulo Fonseca
- Cardiology Department, Vila Nova de Gaia & Espinho Hospital Center, V. N. Gaia, Portugal
| | | | - Lino Gonçalves
- Pacing & Electrophysiology Unit, Cardiology Department, Coimbra's Hospital and University Center, Coimbra, Portugal.,ICBR, Faculty of Medicine, University of Coimbra, Coimbra, Portugal
| | | |
Collapse
|