• Reference Citation Analysis
  • v
  • v
  • Find an Article
Find an Article PDF (4695755)   Today's Articles (51)
For: Samberg ME, Tan Z, Monteiro-Riviere NA, Orndorff PE, Shirwaiker RA. Biocompatibility analysis of an electrically-activated silver-based antibacterial surface system for medical device applications. J Mater Sci Mater Med 2013;24:755-760. [PMID: 23242768 DOI: 10.1007/s10856-012-4838-5] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [What about the content of this article? (0)] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/09/2012] [Accepted: 12/07/2012] [Indexed: 06/01/2023]
Number Cited by Other Article(s)
1
Integration of silver nanoparticles and microcurrent for water filtration. Sep Purif Technol 2019. [DOI: 10.1016/j.seppur.2018.11.016] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/09/2023]
2
Antibacterial efficacy and cytotoxicity of low intensity direct current activated silver–titanium implant system prototype. Biometals 2017;30:113-125. [DOI: 10.1007/s10534-017-9993-1] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/03/2016] [Accepted: 01/06/2017] [Indexed: 12/16/2022]
3
Santos CAD, Seckler MM, Ingle AP, Rai M. Comparative antibacterial activity of silver nanoparticles synthesised by biological and chemical routes with pluronic F68 as a stabilising agent. IET Nanobiotechnol 2016;10:200-5. [PMID: 27463790 PMCID: PMC8676358 DOI: 10.1049/iet-nbt.2015.0055] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/10/2015] [Revised: 11/06/2015] [Accepted: 11/16/2015] [Indexed: 08/13/2023]  Open
4
Effects of Electrically Activated Silver–Titanium Implant System Design Parameters on Time-Kill Curves Against Staphylococcus aureus. J Med Biol Eng 2016. [DOI: 10.1007/s40846-016-0136-x] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/21/2022]
5
Tan Z, Orndorff PE, Shirwaiker RA. Modified Pharmacokinetic/Pharmacodynamic model for electrically activated silver-titanium implant system. BIOMATERIALS AND BIOMECHANICS IN BIOENGINEERING 2015. [DOI: 10.12989/bme.2015.2.3.127] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/22/2022]
6
Cavanaugh DL, Tan ZG, Norris JP, Hardee A, Weinhold PS, Dahners LE, Orndorff PE, Shirwaiker RA. Evaluation of silver-titanium implants activated by low intensity direct current for orthopedic infection control: Anin vitroandin vivostudy. J Biomed Mater Res B Appl Biomater 2015;104:1023-31. [DOI: 10.1002/jbm.b.33451] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/01/2014] [Revised: 03/15/2015] [Accepted: 04/24/2015] [Indexed: 11/07/2022]
7
Tan Z, Ganapathy A, Orndorff PE, Shirwaiker RA. Effects of cathode design parameters on in vitro antimicrobial efficacy of electrically-activated silver-based iontophoretic system. JOURNAL OF MATERIALS SCIENCE. MATERIALS IN MEDICINE 2015;26:5382. [PMID: 25589207 DOI: 10.1007/s10856-015-5382-x] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/12/2014] [Accepted: 09/26/2014] [Indexed: 06/04/2023]
PrevPage 1 of 1 1Next
© 2004-2025 Baishideng Publishing Group Inc. All rights reserved. 7041 Koll Center Parkway, Suite 160, Pleasanton, CA 94566, USA