• Reference Citation Analysis
  • v
  • v
  • Find an Article
Find an Article PDF (4593696)   Today's Articles (2352)   Subscriber (49324)
For: Bullon B, Bueno EF, Herrero M, Fernandez-Palacin A, Rios JV, Bullon P, Gil FJ. Effect of irrigation and stainless steel drills on dental implant bed heat generation. J Mater Sci Mater Med 2015;26:75. [PMID: 25631272 DOI: 10.1007/s10856-015-5412-8] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [What about the content of this article? (0)] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/31/2014] [Accepted: 11/01/2014] [Indexed: 06/04/2023]
Number Cited by Other Article(s)
1
Honda K, Sugimoto K, Kawamura K, Isomoto S, Tanaka Y. Treatment of severe thermal necrosis of the fifth metatarsal after intramedullary screw fixation for proximal diaphyseal stress fracture: A case report. J Orthop Sci 2023;28:1576-1579. [PMID: 34906402 DOI: 10.1016/j.jos.2021.11.001] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/14/2021] [Revised: 10/15/2021] [Accepted: 11/01/2021] [Indexed: 11/17/2022]
2
Bone Healing Evaluation Following Different Osteotomic Techniques in Animal Models: A Suitable Method for Clinical Insights. APPLIED SCIENCES-BASEL 2020. [DOI: 10.3390/app10207165] [Citation(s) in RCA: 9] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/08/2023]
3
Surgical Drill Bit Design and Thermomechanical Damage in Bone Drilling: A Review. Ann Biomed Eng 2020;49:29-56. [PMID: 32860111 DOI: 10.1007/s10439-020-02600-2] [Citation(s) in RCA: 18] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/13/2020] [Accepted: 08/17/2020] [Indexed: 11/27/2022]
4
Salimov F, Ozcan M, Ucak Turer O, Haytac CM. The effects of repeated usage of implant drills on cortical bone temperature, primary/secondary stability and bone healing: A preclinical in vivo micro-CT study. Clin Oral Implants Res 2020;31:687-693. [PMID: 32302433 DOI: 10.1111/clr.13603] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/04/2019] [Revised: 01/27/2020] [Accepted: 04/10/2020] [Indexed: 11/29/2022]
5
Valente MLDC, Castro DTD, Shimano AC, Reis ACD. Influence of an Alternative Implant Design and Surgical Protocol on Primary Stability. Braz Dent J 2019;30:47-51. [PMID: 30864647 DOI: 10.1590/0103-6440201902324] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/28/2018] [Accepted: 09/20/2018] [Indexed: 11/22/2022]  Open
6
Comparative Analysis of the Chemical Composition and Microstructure Conformation Between Different Dental Implant Bone Drills. MATERIALS 2019;12:ma12111866. [PMID: 31181858 PMCID: PMC6601286 DOI: 10.3390/ma12111866] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 04/24/2019] [Revised: 06/01/2019] [Accepted: 06/05/2019] [Indexed: 11/16/2022]
7
Recommended Drilling Parameters of Tungsten Carbide Round Drills for the Most Optimal Bone Removals in Oral Surgery. BIOMED RESEARCH INTERNATIONAL 2018;2018:3108581. [PMID: 30581849 PMCID: PMC6276513 DOI: 10.1155/2018/3108581] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 08/19/2018] [Revised: 10/06/2018] [Accepted: 10/25/2018] [Indexed: 11/18/2022]
8
Domitran Z, Brezak D, Staroveski T, Klaic M, Bruketa T. Experimental and finite element analysis of surgical drill bits with and without irrigation channel - A case study approach. Med Eng Phys 2018;62:29-35. [PMID: 30337053 DOI: 10.1016/j.medengphy.2018.10.004] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/07/2017] [Revised: 09/24/2018] [Accepted: 10/07/2018] [Indexed: 10/28/2022]
9
Sindel A, Dereci Ö, Hatipoğlu M, Altay MA, Özalp Ö, Öztürk A. The effects of irrigation volume to the heat generation during implant surgery. Med Oral Patol Oral Cir Bucal 2017. [PMID: 28624839 PMCID: PMC5549525 DOI: 10.4317/medoral.21880] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/18/2022]  Open
10
Intraosseous Heat Production and Preparation Efficiency of Surgical Tungsten Carbide Round Drills: The Effect of Coronectomy on Drill Wear. J Oral Maxillofac Surg 2016;74:442-52. [DOI: 10.1016/j.joms.2015.11.012] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/31/2015] [Revised: 10/02/2015] [Accepted: 11/10/2015] [Indexed: 11/20/2022]
PrevPage 1 of 1 1Next
© 2004-2024 Baishideng Publishing Group Inc. All rights reserved. 7041 Koll Center Parkway, Suite 160, Pleasanton, CA 94566, USA