1
|
Venketasubramanian N, Yeo LLL, Tan B, Chan BPL. Sonothrombolysis for Ischemic Stroke. J Cardiovasc Dev Dis 2024; 11:75. [PMID: 38535098 PMCID: PMC10971528 DOI: 10.3390/jcdd11030075] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/22/2023] [Revised: 02/14/2024] [Accepted: 02/17/2024] [Indexed: 01/03/2025] Open
Abstract
Stroke is a major cause of death and disability globally, with ischemic stroke being the predominant mechanism. While spontaneous recanalization may occur, significant neuronal injury would have occurred in the interim. Intravenous thrombolysis administered within the first 4.5 h after stroke onset and endovascular thrombectomy within 24 h in patients with a salvageable penumbra improves functional independence. Ultrasound has been shown in both in vivo and in vitro models to enhance clot lysis, even more-so in the presence of thrombolytic agents. The use of transcranial Doppler and transcranial color-coded Doppler ultrasound in acute IS has been reported in case series, case-controlled studies, and clinical trials. While ultrasound at a frequency of 300 kHz increases the risk of intracranial hemorrhage, the 2 MHz range ultrasound aids thrombolysis and improves recanalization without significantly increasing the risk of symptomatic intracranial hemorrhage. Despite this, functional independence was not increased in clinical trials, nor was a benefit shown with the adjunctive use of microbubbles or microspheres. Nonetheless, newer technologies such as endovascular ultrasound, endovascular delivery of microbubbles, and thrombolytic-filled microbubbles await clinical trials. More evidence is needed before sonothrombolysis can be routinely used in the hyperacute management of ischemic stroke.
Collapse
Affiliation(s)
| | - Leonard L. L. Yeo
- Division of Neurology, National University Hospital, Singapore and Yong Loo Lin School of Medicine, National University of Singapore, Singapore 119074, Singapore; (L.L.L.Y.); (B.T.); (B.P.L.C.)
| | - Benjamin Tan
- Division of Neurology, National University Hospital, Singapore and Yong Loo Lin School of Medicine, National University of Singapore, Singapore 119074, Singapore; (L.L.L.Y.); (B.T.); (B.P.L.C.)
| | - Bernard P. L. Chan
- Division of Neurology, National University Hospital, Singapore and Yong Loo Lin School of Medicine, National University of Singapore, Singapore 119074, Singapore; (L.L.L.Y.); (B.T.); (B.P.L.C.)
| |
Collapse
|
2
|
Contrast Ultrasound, Sonothrombolysis and Sonoperfusion in Cardiovascular Disease: Shifting to Theragnostic Clinical Trials. JACC Cardiovasc Imaging 2022; 15:345-360. [PMID: 34656483 PMCID: PMC8837667 DOI: 10.1016/j.jcmg.2021.07.028] [Citation(s) in RCA: 19] [Impact Index Per Article: 6.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/16/2021] [Accepted: 07/23/2021] [Indexed: 02/03/2023]
Abstract
Contrast ultrasound has a variety of applications in cardiovascular medicine, both in diagnosing cardiovascular disease as well as providing prognostic information. Visualization of intravascular contrast microbubbles is based on acoustic cavitation, the characteristic oscillation that results in changes in the reflected ultrasound waves. At high power, this acoustic response generates sufficient shear that is capable of enhancing endothelium-dependent perfusion in atherothrombotic cardiovascular disease (sonoperfusion). The oscillation and collapse of microbubbles in response to ultrasound also induces microstreaming and jetting that can fragment thrombus (sonothrombolysis). Several preclinical studies have focused on identifying optimal diagnostic ultrasound settings and treatment regimens. Clinical trials have been performed in acute myocardial infarction, stroke, and peripheral arterial disease often with improved outcome. In the coming years, results of ongoing clinical trials along with innovation and improvements in sonothrombolysis and sonoperfusion will determine whether this theragnostic technique will become a valuable addition to reperfusion therapy.
Collapse
|
3
|
Masomi-Bornwasser J, Fabrig O, Krenzlin H, König J, Tanyildizi Y, Kempski O, Ringel F, Keric N. Systematic Analysis of Combined Thrombolysis Using Ultrasound and Different Fibrinolytic Drugs in an in Vitro Clot Model of Intracerebral Hemorrhage. ULTRASOUND IN MEDICINE & BIOLOGY 2021; 47:1334-1342. [PMID: 33549380 DOI: 10.1016/j.ultrasmedbio.2021.01.005] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/30/2020] [Revised: 01/07/2021] [Accepted: 01/07/2021] [Indexed: 06/12/2023]
Abstract
Adequate removal of blood clots by minimally invasive surgery seems to correlate with a better clinical outcome in patients with intracerebral hemorrhages (ICHs). Moreover, neurotoxic effects of recombinant tissue plasminogen activator have been reported. The aim of this study was to improve fibrinolysis using an intra-clot ultrasound application with tenecteplase and urokinase in our established ICH clot model. One hundred thirty clots were produced from 25 or 50 mL of human blood, incubated for different periods and equipped with drainage, through which an ultrasound catheter was placed in 65 treatment clots for 1 h, randomly allocated into three groups: administration of ultrasound, administration of 60 IU of tenecteplase or administration of 30,000 IU urokinase. Relative end weights were compared. This study found a significant increase in thrombolysis caused by a combination of ultrasound and fibrinolytic drugs, whereas ultrasound and tenecteplase are significantly more effective in the treatment of larger and aged clots.
Collapse
Affiliation(s)
- Julia Masomi-Bornwasser
- Department of Neurosurgery, University Medical Center of the Johannes Gutenberg University, Mainz, Germany.
| | - Oliver Fabrig
- Department of Neurosurgery, University Medical Center of the Johannes Gutenberg University, Mainz, Germany
| | - Harald Krenzlin
- Department of Neurosurgery, University Medical Center of the Johannes Gutenberg University, Mainz, Germany
| | - Jochem König
- Institute of Medical Biostatistics, Epidemiology and Informatics (IMBEI), University Medical Centre of the Johannes Gutenberg University, Mainz, Germany
| | - Yasemin Tanyildizi
- Department of Neuroradiology, University Medical Center of the Johannes Gutenberg University, Mainz, Germany
| | - Oliver Kempski
- Institute for Neurosurgical Pathophysiology, University Medical Center of the Johannes Gutenberg University, Mainz, Germany
| | - Florian Ringel
- Department of Neurosurgery, University Medical Center of the Johannes Gutenberg University, Mainz, Germany
| | - Naureen Keric
- Department of Neurosurgery, University Medical Center of the Johannes Gutenberg University, Mainz, Germany
| |
Collapse
|
4
|
Sujarittam K, Choi JJ. Angular dependence of the acoustic signal of a microbubble cloud. THE JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA 2020; 148:2958. [PMID: 33261381 DOI: 10.1121/10.0002490] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/17/2020] [Accepted: 10/22/2020] [Indexed: 06/12/2023]
Abstract
Microbubble-mediated ultrasound therapies have a common need for methods that can noninvasively monitor the treatment. One approach is to use the bubbles' acoustic emissions as feedback to the operator or a control unit. Current methods interpret the emissions' frequency content to infer the microbubble activities and predict therapeutic outcomes. However, different studies placed their sensors at different angles relative to the emitter and bubble cloud. Here, it is evaluated whether such angles influence the captured emissions such as the frequency content. In computer simulations, 128 coupled bubbles were sonicated with a 0.5-MHz, 0.35-MPa pulse, and the acoustic emissions generated by the bubbles were captured with two sensors placed at different angles. The simulation was replicated in experiments using a microbubble-filled gel channel (0.5-MHz, 0.19-0.75-MPa pulses). A hydrophone captured the emissions at two different angles. In both the simulation and the experiments, one angle captured periodic time-domain signals, which had high contributions from the first three harmonics. In contrast, the other angle captured visually aperiodic time-domain features, which had much higher harmonic and broadband content. Thus, by placing acoustic sensors at different positions, substantially different acoustic emissions were captured, potentially leading to very different conclusions about the treatment outcome.
Collapse
Affiliation(s)
- Krit Sujarittam
- Department of Bioengineering, Imperial College London, 2 Imperial College Road, South Kensington, London, SW7 2AZ, United Kingdom
| | - James J Choi
- Department of Bioengineering, Imperial College London, 2 Imperial College Road, South Kensington, London, SW7 2AZ, United Kingdom
| |
Collapse
|
5
|
Masomi-Bornwasser J, Winter P, Neulen A, Kantelhardt SR, König J, Kempski O, Ringel F, Keric N. Doppler sonography enhances rtPA-induced fibrinolysis in an in vitro clot model of spontaneous intracerebral hemorrhages. PLoS One 2019; 14:e0210810. [PMID: 30653589 PMCID: PMC6336417 DOI: 10.1371/journal.pone.0210810] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/31/2018] [Accepted: 01/02/2019] [Indexed: 01/25/2023] Open
Abstract
Background Transcranial Doppler (TCD) was shown to enhance intravascular fibrinolysis by rtPA in ischemic stroke. Studies revealed that catheter-based administration of rtPA induces lysis of intracerebral hemorrhages (ICH). However, it is unknown whether TCD would be suitable to enhance rtPA-induced fibrinolysis in patients with ICH. The aim of this study was to assess the potential of TCD to enhance rtPA-induced fibrinolysis in an in vitro clot system. Methods Reproducible human blood clots of 25 ml were incubated in a water bath at 37°C during treatments. They were weighed before and after 6 different treatments: (I) control (incubation only), (II) rtPA only, (III) one Doppler probe, (IV) two Doppler probes placed vis-à-vis, (V) one probe and rtPA and (VI) two probes and rtPA. To quantify lysis of the blood clots and attenuation of the Doppler through a temporal squama acoustic peak rarefaction pressure (APRP) was measured in the field of the probes. Temperature was assessed to evaluate possible side effects. Results Clot weight was reduced in all groups. The control group had the highest relative end weight of 70.2%±7.2% compared to all other groups (p<0,0001). Most efficient lysis was achieved using (VI) 2 probes and rtPA 36.3%±4.4% compared to (II, III, IV) (p<0.0001; p = 0.0002; p = 0.048). APRP was above lysis threshold (535.5±7.2 kPa) using 2 probes even through the temporal squama (731.6±32.5 kPa) (p = 0.0043). There was a maximal temperature elevation of 0.17±0.07°C using both probes. Conclusions TCD significantly enhances rtPA-induced lysis of blood clots, and the effect is amplified by using multiple probes. Our results indicate that bitemporal TCD insonation of hematomas could be a new and safe approach to enhance fibrinolysis of ICH´s treated with intralesional catheter and rtPA.
Collapse
Affiliation(s)
- Julia Masomi-Bornwasser
- Department of Neurosurgery, University Medical Center of the Johannes Gutenberg University, Mainz, Germany
- * E-mail:
| | - Philipp Winter
- Department of Neurosurgery, University Medical Center of the Johannes Gutenberg University, Mainz, Germany
| | - Axel Neulen
- Department of Neurosurgery, University Medical Center of the Johannes Gutenberg University, Mainz, Germany
| | - Sven R. Kantelhardt
- Department of Neurosurgery, University Medical Center of the Johannes Gutenberg University, Mainz, Germany
| | - Jochem König
- Institute of Medical Biostatistics, Epidemiology and Informatics (IMBEI), University Medical Center of the Johannes Gutenberg University, Mainz, Germany
| | - Oliver Kempski
- Institute of Neurosurgical Pathophysiology, University Medical Center of the Johannes Gutenberg University, Mainz, Germany
| | - Florian Ringel
- Department of Neurosurgery, University Medical Center of the Johannes Gutenberg University, Mainz, Germany
| | - Naureen Keric
- Department of Neurosurgery, University Medical Center of the Johannes Gutenberg University, Mainz, Germany
| |
Collapse
|
6
|
Combination of ultrasound and rtPA enhances fibrinolysis in an In Vitro clot system. PLoS One 2017; 12:e0188131. [PMID: 29145482 PMCID: PMC5690612 DOI: 10.1371/journal.pone.0188131] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/09/2017] [Accepted: 11/01/2017] [Indexed: 11/19/2022] Open
Abstract
BACKGROUND Catheter-based lysis with recombinant tissue plasminogen activator (rtPA) is a well-established therapy for spontaneous intracerebral hemorrhage (ICH). The effectiveness of this therapy can be increased with ultrasound, but the optimal conditions are not yet clearly established. Using a novel in vitro system of blood clots previously developed by our group, we investigated various parameters of intralesional sonothrombolysis using an endosonography catheter in combination with rtPA. METHODS Standardized human blood clots were equipped with a drainage catheter and weighed before and after 4 treatments: control (drainage only), rtPA only, ultrasound only and the combination of rtPA+ultrasound. The effectiveness of ultrasound was further analysed in terms of optimal frequency, duration and distance to the probe. Temperature and acoustic peak rarefaction pressure (APRP) were assessed to analyse potential adverse effects and quantify lysis. Histo-morphological analysis of the treated clots was performed by H&E staining and confocal laser scanning microscopy using fluorescent fibrinogen. RESULTS The combined treatment rtPA+ultrasound achieved the highest lysis rates with a relative weight of 30.3%±5.5% (p≤0.0001) compared to all other groups. Similar results were observed when treating aged clots. Confocal fluorescent microscopy of the treated clots revealed a rarefied fibrin mesh without cavitations. No relevant temperature increase occurred (0.53±0.75°C). The optimal insonation treatment time was 1 hour. APRP measurements showed a lysis threshold of 515.5±113.4 kPa. Application of 10 MHz achieved optimal lysis and lysis radius, while simultaneously proving to be the best frequency for morphologic imaging of the clot and surrounding tissue. CONCLUSIONS These promising data provide the basis for an individualized minimal invasive ICH therapy by rtPA and sonothrombolysis independent of ICH age.
Collapse
|
7
|
Paefgen V, Doleschel D, Kiessling F. Evolution of contrast agents for ultrasound imaging and ultrasound-mediated drug delivery. Front Pharmacol 2015; 6:197. [PMID: 26441654 PMCID: PMC4584939 DOI: 10.3389/fphar.2015.00197] [Citation(s) in RCA: 180] [Impact Index Per Article: 18.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/06/2015] [Accepted: 08/31/2015] [Indexed: 12/21/2022] Open
Abstract
Ultrasound (US) is one of the most frequently used diagnostic methods. It is a non-invasive, comparably inexpensive imaging method with a broad spectrum of applications, which can be increased even more by using bubbles as contrast agents (CAs). There are various different types of bubbles: filled with different gases, composed of soft- or hard-shell materials, and ranging in size from nano- to micrometers. These intravascular CAs enable functional analyses, e.g., to acquire organ perfusion in real-time. Molecular analyses are achieved by coupling specific ligands to the bubbles' shell, which bind to marker molecules in the area of interest. Bubbles can also be loaded with or attached to drugs, peptides or genes and can be destroyed by US pulses to locally release the entrapped agent. Recent studies show that US CAs are also valuable tools in hyperthermia-induced ablation therapy of tumors, or can increase cellular uptake of locally released drugs by enhancing membrane permeability. This review summarizes important steps in the development of US CAs and introduces the current clinical applications of contrast-enhanced US. Additionally, an overview of the recent developments in US probe design for functional and molecular diagnosis as well as for drug delivery is given.
Collapse
Affiliation(s)
| | | | - Fabian Kiessling
- Institute for Experimental Molecular Imaging, RWTH Aachen University Hospital, AachenGermany
| |
Collapse
|
8
|
Petit B, Yan F, Bussat P, Bohren Y, Gaud E, Fontana P, Tranquart F, Allémann E. Fibrin degradation during sonothrombolysis – Effect of ultrasound, microbubbles and tissue plasminogen activator. J Drug Deliv Sci Technol 2015. [DOI: 10.1016/j.jddst.2014.12.001] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
|
9
|
Acconcia C, Leung BYC, Manjunath A, Goertz DE. Interactions between individual ultrasound-stimulated microbubbles and fibrin clots. ULTRASOUND IN MEDICINE & BIOLOGY 2014; 40:2134-2150. [PMID: 24882525 DOI: 10.1016/j.ultrasmedbio.2014.03.008] [Citation(s) in RCA: 16] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/01/2013] [Revised: 02/23/2014] [Accepted: 03/06/2014] [Indexed: 06/03/2023]
Abstract
The use of ultrasound-stimulated microbubbles (USMBs) to promote thrombolysis is well established, but there remains considerable uncertainty about the mechanisms of this process. Here we examine the microscale interactions between individual USMBs and fibrin clots as a function of bubble size, exposure conditions and clot type. Microbubbles (n = 185) were placed adjacent to clot boundaries ("coarse" or "fine") using optical tweezers and exposed to 1-MHz ultrasound as a function of pressure (0.1-0.39 MPa). High-speed (10 kfps) imaging was employed, and clots were subsequently assessed with 2-photon microscopy. For fine clots, 46% of bubbles "embedded" within 10 μm of the clot boundary at pressures of 0.1 and 0.2 MPa, whereas at 0.39 MPa, 53% of bubbles penetrated and transited into the clots with an incidence inversely related to their diameter. A substantial fraction of penetrating bubbles induced fibrin network damage and promoted the uptake of nanobeads. In coarse clots, penetration occurred more readily and at lower pressures than in fine clots. The results therefore provide direct evidence of therapeutically relevant effects of USMBs and indicate their dependence on size, exposure conditions and clot properties.
Collapse
Affiliation(s)
- Christopher Acconcia
- Department of Medical Biophysics, University of Toronto, Toronto, Ontario, Canada; Sunnybrook Research Institute, Toronto, Ontario, Canada.
| | - Ben Y C Leung
- Sunnybrook Research Institute, Toronto, Ontario, Canada
| | | | - David E Goertz
- Department of Medical Biophysics, University of Toronto, Toronto, Ontario, Canada; Sunnybrook Research Institute, Toronto, Ontario, Canada
| |
Collapse
|
10
|
de Saint Victor M, Crake C, Coussios CC, Stride E. Properties, characteristics and applications of microbubbles for sonothrombolysis. Expert Opin Drug Deliv 2014; 11:187-209. [DOI: 10.1517/17425247.2014.868434] [Citation(s) in RCA: 53] [Impact Index Per Article: 4.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/27/2022]
|
11
|
Soltani A. Application of cavitation promoting surfaces in management of acute ischemic stroke. ULTRASONICS 2013; 53:580-587. [PMID: 23141666 PMCID: PMC3510343 DOI: 10.1016/j.ultras.2012.10.002] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/24/2012] [Revised: 08/27/2012] [Accepted: 10/04/2012] [Indexed: 06/01/2023]
Abstract
High frequency, low intensity ultrasound has the potential to accelerate the clearance of thrombotic occlusion in the absence of cavitation. At high frequency ultrasound, high acoustic pressures, >5.2MPa, are required to generate cavitation in thrombus. The focus of this study was to reduce the cavitation threshold by applying materials with appropriate nucleation sites at the transducer-thrombus boundary to further augment sonothrombolysis. Heterogeneous and homogenous nucleation sites were generated on the outer surface of a polyimide tube (PI) using microfringed (MPI) and laser induced (LPI) microcavities. The cavitation threshold of these materials was determined using a passive cavitation detection system. Furthermore, the biological impact of both materials was investigated in vitro. The results revealed that both MPI and LPI have the potential to induce cavitation at acoustic pressure levels as low as 2.3MPa. In the presence of cavitation, thrombolysis rate could be enhanced by up to two times without any evidence of hemolysis that is generally associated with cavitation activities in blood. A prototype ultrasonic catheter operating at 1.7MHz frequency and acoustic pressure of 2.3MPa with either of MPI or LPI could be considered as a viable option for treatment of acute ischemic stroke.
Collapse
Affiliation(s)
- Azita Soltani
- R&D Department, EKOS Corporation, 11911 N Creek Parkway S, Bothell, WA 98011, USA.
| |
Collapse
|
12
|
Removing vascular obstructions: a challenge, yet an opportunity for interventional microdevices. Biomed Microdevices 2012; 14:511-32. [PMID: 22331446 DOI: 10.1007/s10544-011-9627-2] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/28/2022]
Abstract
Cardiovascular diseases are the leading cause of death worldwide; they are mainly due to vascular obstructions which, in turn, are mainly caused by thrombi and atherosclerotic plaques. Although a variety of removal strategies has been developed for the considered obstructions, none of them is free from limitations and conclusive. The present paper analyzes the physical mechanisms underlying state-of-art removal strategies and classifies them into chemical, mechanical, laser and hybrid (namely chemo-mechanical and mechano-chemical) approaches, while also reviewing corresponding commercial/research tools/devices and procedures. Furthermore, challenges and opportunities for interventional micro/nanodevices are highlighted. In this spirit, the present review should support engineers, researchers active in the micro/nanotechnology field, as well as medical doctors in the development of innovative biomedical solutions for treating vascular obstructions. Data were collected by using the ISI Web of Knowledge portal, buyer's guides and FDA databases; devices not reported on scientific publications, as well as commercial devices no more for sale were discarded. Nearly 70% of the references were published since 2006, 55% since 2008; these percentages respectively raise to 85% and 65% as regards the section specifically reviewing state-of-art removal tools/devices and procedures.
Collapse
|
13
|
Petit B, Gaud E, Colevret D, Arditi M, Yan F, Tranquart F, Allémann E. In vitro sonothrombolysis of human blood clots with BR38 microbubbles. ULTRASOUND IN MEDICINE & BIOLOGY 2012; 38:1222-1233. [PMID: 22542261 DOI: 10.1016/j.ultrasmedbio.2012.02.023] [Citation(s) in RCA: 33] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/06/2011] [Revised: 02/22/2012] [Accepted: 02/23/2012] [Indexed: 05/31/2023]
Abstract
Microbubble-mediated sonothrombolysis is a promising approach for ischemic stroke treatment. The aim of this in vitro study was to evaluate a new microbubble (MB) formulation (BR38) for sonothrombolysis and to investigate the involved mechanisms. Human whole-blood clots were exposed to different combinations of recombinant tissue plasminogen activator (rtPA), ultrasound (US) and MB. Ultrasound at 1.6 MHz was used at 150, 300, 600 and 1000 kPa (peak-negative pressure). Thrombolysis efficacy was assessed by measuring clot diameter changes during 60-min US exposure. The rate of clot diameter loss (RDL) in μm/min was determined and clot lysis profiles were analyzed. The most efficient clot lysis (5.9 μm/min) was obtained at acoustic pressures of 600 and 1000 kPa in combination with MB and a low concentration of rtPA (0.3 μg/mL). This is comparable with the rate obtained with rtPA at 3 μg/mL alone (6.6 μm/min, p > 0.05). Clot lysis profiles were shown to be related to US beam profiles and microbubble cavitation.
Collapse
Affiliation(s)
- Bénédicte Petit
- School of Pharmaceutical Sciences, University of Geneva, University of Lausanne, Geneva, Switzerland.
| | | | | | | | | | | | | |
Collapse
|
14
|
Bor-Seng-Shu E, Nogueira RDC, Figueiredo EG, Evaristo EF, Conforto AB, Teixeira MJ. Sonothrombolysis for acute ischemic stroke: a systematic review of randomized controlled trials. Neurosurg Focus 2012; 32:E5. [PMID: 22208898 DOI: 10.3171/2011.10.focus11251] [Citation(s) in RCA: 19] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
Abstract
OBJECT Sonothrombolysis has recently been considered an emerging modality for the treatment of stroke. The purpose of the present paper was to review randomized clinical studies concerning the effects of sonothrombolysis associated with tissue plasminogen activator (tPA) on acute ischemic stroke. METHODS Systematic searches for literature published between January 1996 and July 2011 were performed for studies regarding sonothrombolysis combined with tPA for acute ischemic stroke. Only randomized controlled trials were included. Data extraction was based on ultrasound variables, patient characteristics, and outcome variables (rate of intracranial hemorrhages and arterial recanalization). RESULTS Four trials were included in this study; 2 trials evaluated the effect of transcranial Doppler (TCD) ultrasonography on sonothrombolysis, and 2 addressed transcranial color-coded duplex (TCCD) ultrasonography. The frequency of ultrasound waves varied from 1.8 to 2 MHz. The duration of thrombus exposure to ultrasound energy ranged from 60 to 120 minutes. Sample sizes were small, recanalization was evaluated at different time points (60 and 120 minutes), and inclusion criteria were heterogeneous. Sonothrombolysis combined with tPA did not lead to an increase in symptomatic intracranial hemorrhagic complications. Two studies demonstrated that patients treated with ultrasound combined with tPA had statistically significant higher rates of recanalization than patients treated with tPA alone. CONCLUSIONS Despite the heterogeneity and the limitations of the reviewed studies, there is evidence that sonothrombolysis associated with tPA is a safe procedure and results in an increased rate of recanalization in the setting of acute ischemic stroke when wave frequencies and energy intensities of diagnostic ultrasound systems are used.
Collapse
Affiliation(s)
- Edson Bor-Seng-Shu
- Division of Neurological Surgery, Hospital das Clinicas, University of Sao Paulo School of Medicine, Sao Paulo, Brazil.
| | | | | | | | | | | |
Collapse
|
15
|
Rubiera M, Molina CA. Use of Microbubbles in Acute Stroke. Transl Stroke Res 2012. [DOI: 10.1007/978-1-4419-9530-8_36] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/28/2022]
|
16
|
Petit B, Yan F, Tranquart F, Allémann E. Microbubbles and ultrasound-mediated thrombolysis: a review of recent in vitro studies. J Drug Deliv Sci Technol 2012. [DOI: 10.1016/s1773-2247(12)50065-1] [Citation(s) in RCA: 11] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
|