Li Y, Liu G, Lou X, Chen Z, Ma L. Intra-individual comparison of different gadolinium-based contrast agents in the quantitative evaluation of C6 glioma with dynamic contrast-enhanced magnetic resonance imaging.
SCIENCE CHINA-LIFE SCIENCES 2017;
60:11-15. [PMID:
28078511 DOI:
10.1007/s11427-016-0386-2]
[Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/25/2016] [Accepted: 09/13/2016] [Indexed: 12/12/2022]
Abstract
This experiment aimed to compare the ionic (Gadodiamide, Gd-DTPA-BMA) and non-ionic (Gadopentetate dimeglumine, Gd-DTPA) gadolinium-based contrast agents (GBCA) in the quantitative evaluation of C6 glioma with dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI). A C6 glioma model was established in 12 Wistar rats, and magnetic resonance (MR) scans were performed six days after tumor implantation. Imaging was performed using a 3.0-T MR scanner with a 7-inch handmade circular coil. Pre-contrast T1 mapping and dynamic contrast-enhanced T1WI after a bolus injection (0.2 mL s-1) of GBCA at 0.4 mmol kg-1 were performed. Each rat received two DCE-MRI scans, 24 h apart. The first and second scans were performed using Gd-DTPA-BMA and Gd-DTPA, respectively. Image data were processed using the Patlak model. Both K trans and V p maps were generated. Tumors were manually segmented on all 3D K trans and V p maps. Pixel counts and mean values were recorded for use in a paired t-test. Three radiologists independently performed the tumor segmentation and value calculation. The agreements from different observers were subjective to the intra-class correlation coefficient (ICC). Readers demonstrated that the pixel counts of tumors in K trans maps were higher with Gd-DTPA-BMA than with Gd-DTPA (P<0.001, all readers). Although the K trans values were higher with Gd-DTPA-BMA than with Gd-DTPA, there was no statistical significance (P>0.05, all readers). The pixel counts of tumors in V p maps, as well as V p values, showed no obvious difference between the two agents (P>0.05, all readers). Excellent interobserver measurement reproducibility and reliability were demonstrated in the ICC tests. The Gd-DTPA-BMA contrast agent had significantly higher pixel counts of glioma in the K trans maps, and an increased tendency for average K trans values, indicating that DCE-MRI with Gd-DTPA-BMA may be more suitable and sensitive for the evaluation of glioma.
Collapse