1
|
R S, S H, Karnan H, V K, V A. Numerical modeling and analysis of cardiac stent using blood hammer principle. Technol Health Care 2024; 32:4223-4238. [PMID: 39093086 PMCID: PMC11613089 DOI: 10.3233/thc-240051] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/06/2024] [Accepted: 05/10/2024] [Indexed: 08/04/2024]
Abstract
BACKGROUND Atherosclerosis is a condition which disrupts blood flow due to plaque build-up inside the arteries. Under conditions where consecutive plaques are prevailing blood hammer principle is exhibited. OBJECTIVE The pressure and shear stress produced at an infinitesimal area act as the governing equation for stent modeling. The leading order pressure lays the foundation for the design of cardiac stents with definite dimensions. METHOD The designed stent was encapsulated inside a crimper validated through ANSYS-static and transient structural simulation to derive the total deformation, equivalent strain, and stress exerted on the stent. Five different biomaterials stainless steel 316, cobalt, chromium, platinum, and Poly lactic acid were selected for the material assessment. RESULT Static and Transient structural analysis for a period of 1 and 10 secs was implemented for a stent with and without a crimper. The material performance in terms of total deformation, equivalent stress, and strain are analyzed. CONCLUSION The paper envisions the dynamics of blood hammer in atherosclerosis that provides the changes in the pressure and clotting process. It shows the promising results of the stent behavior in varied forces which gives valuable insights for future improvement in stent design and material selection.
Collapse
Affiliation(s)
- Seethalakshmi R
- School of Arts Sciences, Humanities and Education, SASTRA Deemed University, Thanjavur, Tamil Nadu, India
| | - Hariharan S
- School of Chemical and Biotechnology, SASTRA Deemed University, Thanjavur, Tamil Nadu, India
| | - Hemalatha Karnan
- School of Chemical and Biotechnology, SASTRA Deemed University, Thanjavur, Tamil Nadu, India
| | - Keerthana V
- School of Chemical and Biotechnology, SASTRA Deemed University, Thanjavur, Tamil Nadu, India
| | - Akshara V
- School of Chemical and Biotechnology, SASTRA Deemed University, Thanjavur, Tamil Nadu, India
| |
Collapse
|
2
|
Wang Y, Zhao Y, Wang X, Xie Y, Bai L, Guan S. Fucoidan/collagen composite coating on magnesium alloy for better corrosion resistance and pro-endothelialization potential. Int J Biol Macromol 2024; 255:128044. [PMID: 37981269 DOI: 10.1016/j.ijbiomac.2023.128044] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/04/2023] [Revised: 11/03/2023] [Accepted: 11/09/2023] [Indexed: 11/21/2023]
Abstract
Magnesium alloy stents (MAS) have broad application prospects in the treatment of cardiovascular diseases. However, poor corrosion resistance and biocompatibility greatly limit the clinical application of MAS. In this work, the coating consisting of MgF2 layer, polydopamine layer, fucoidan and collagen IV was constructed on Mg-Zn-Y-Nd (ZE21B) alloy to improve its corrosion resistance and pro-endothelialization potential. The fucoidan and collagen IV in the coating could obviously enhance the hemocompatibility and pro-endothelialization potential respectively. Compared with bare ZE21B alloy, the fucoidan/collagen composite coating modified ZE21B alloy possessed lower corrosion current density and better corrosion resistance. Moreover, the modified ZE21B alloy exhibited relatively low hemolysis rate, fibrinogen adsorption and platelet adhesion in the blood experiments, suggesting the improved hemocompatibility. Furthermore, the modified ZE21B alloy favorably supported the adhesion and proliferation of vascular endothelial cells (ECs) and effectively regulated the phenotype of smooth muscle cells (SMCs), thus improving the pro-endothelialization potential of vascular stent materials. The fucoidan/collagen composite coating can significantly improve the corrosion resistance and pro-endothelialization potential of ZE21B alloy, showing great potential in the development of degradable MAS.
Collapse
Affiliation(s)
- Yahui Wang
- School of Materials Science and Engineering, Zhengzhou University, Zhengzhou 450001, China; Henan Key Laboratory of Advanced Magnesium Alloys, Zhengzhou 450002, China
| | - Yuan Zhao
- School of Materials Science and Engineering, Zhengzhou University, Zhengzhou 450001, China; Henan Key Laboratory of Advanced Magnesium Alloys, Zhengzhou 450002, China
| | - Xinyu Wang
- School of Materials Science and Engineering, Zhengzhou University, Zhengzhou 450001, China; Henan Key Laboratory of Advanced Magnesium Alloys, Zhengzhou 450002, China
| | - Yinde Xie
- School of Materials Science and Engineering, Zhengzhou University, Zhengzhou 450001, China.
| | - Lingchuang Bai
- School of Materials Science and Engineering, Zhengzhou University, Zhengzhou 450001, China; Henan Key Laboratory of Advanced Magnesium Alloys, Zhengzhou 450002, China.
| | - Shaokang Guan
- School of Materials Science and Engineering, Zhengzhou University, Zhengzhou 450001, China; Henan Key Laboratory of Advanced Magnesium Alloys, Zhengzhou 450002, China; Key Laboratory of Materials Processing and Mold Technology, Ministry of Education, Zhengzhou 450002, China
| |
Collapse
|
3
|
Liu D, Yang K, Chen S. Development and Future Trends of Protective Strategies for Magnesium Alloy Vascular Stents. MATERIALS (BASEL, SWITZERLAND) 2023; 17:68. [PMID: 38203922 PMCID: PMC10779993 DOI: 10.3390/ma17010068] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/21/2023] [Revised: 12/09/2023] [Accepted: 12/20/2023] [Indexed: 01/12/2024]
Abstract
Magnesium alloy stents have been extensively studied in the field of biodegradable metal stents due to their exceptional biocompatibility, biodegradability and excellent biomechanical properties. Nevertheless, the specific in vivo service environment causes magnesium alloy stents to degrade rapidly and fail to provide sufficient support for a certain time. Compared to previous reviews, this paper focuses on presenting an overview of the development history, the key issues, mechanistic analysis, traditional protection strategies and new directions and protection strategies for magnesium alloy stents. Alloying, optimizing stent design and preparing coatings have improved the corrosion resistance of magnesium alloy stents. Based on the corrosion mechanism of magnesium alloy stents, as well as their deformation during use and environmental characteristics, we present some novel strategies aimed at reducing the degradation rate of magnesium alloys and enhancing the comprehensive performance of magnesium alloy stents. These strategies include adapting coatings for the deformation of the stents, preparing rapid endothelialization coatings to enhance the service environment of the stents, and constructing coatings with self-healing functions. It is hoped that this review can help readers understand the development of magnesium alloy cardiovascular stents and solve the problems related to magnesium alloy stents in clinical applications at the early implantation stage.
Collapse
Affiliation(s)
- Dexiao Liu
- Shi-Changxu Innovation Center for Advanced Materials, Institute of Metal Research, Chinese Academy of Sciences, Shenyang 110016, China
- School of Materials Science and Engineering, University of Science and Technology of China, Shenyang 110016, China
| | - Ke Yang
- Shi-Changxu Innovation Center for Advanced Materials, Institute of Metal Research, Chinese Academy of Sciences, Shenyang 110016, China
| | - Shanshan Chen
- Shi-Changxu Innovation Center for Advanced Materials, Institute of Metal Research, Chinese Academy of Sciences, Shenyang 110016, China
| |
Collapse
|
4
|
Tong P, Chen L, Sun X, Li H, Feng Y, Li J, Guan S. Surface modification of biodegradable magnesium alloy with poly (L-lactic acid) and sulfonated hyaluronic acid nanoparticles for cardiovascular application. Int J Biol Macromol 2023; 237:124191. [PMID: 36990404 DOI: 10.1016/j.ijbiomac.2023.124191] [Citation(s) in RCA: 8] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/02/2023] [Revised: 03/07/2023] [Accepted: 03/23/2023] [Indexed: 03/29/2023]
Abstract
Magnesium (Mg) and its alloys have attracted extensive attention of researchers in the field of cardiovascular implants due to their good mechanical properties and biosafety. Constructing a multifunctional hybrid coating seems to be an effective strategy to address the insufficient endothelialization and poor corrosion resistance of Mg alloy vascular stents. In this study, a dense layer of magnesium fluoride (MgF2) was prepared on the surface of Mg alloy aiming at better corrosion resistance; Thereafter, sulfonated hyaluronic acid (S-HA) was made into small sized nanoparticles (NP) which were deposited on the MgF2 surface by self-assembly method, followed with poly-L-lactic acid (PLLA) coating preparation by one-step pulling method. The blood and cell tests showed that the composite coating had good blood compatibility, pro-endothelial, anti-hyperplasia and anti-inflammatory functions. Compared to current clinical PLLA@ Rapamycin coating, our PLLA/NP@S-HA coating showed better functions of promoting endothelial cells growth. These results strongly furnished a promising and feasible strategy for the surface modification of Mg-based degradable cardiovascular stents.
Collapse
Affiliation(s)
- Peiduo Tong
- School of Material Science and Engineering & Henan Key Laboratory of Advanced Magnesium Alloy & Key Laboratory of Materials Processing and Mold Technology (Ministry of Education), Zhengzhou University, 100 Science Road, Zhengzhou 450001, PR China
| | - Lan Chen
- School of Material Science and Engineering & Henan Key Laboratory of Advanced Magnesium Alloy & Key Laboratory of Materials Processing and Mold Technology (Ministry of Education), Zhengzhou University, 100 Science Road, Zhengzhou 450001, PR China
| | - Xiaojing Sun
- School of Material Science and Engineering & Henan Key Laboratory of Advanced Magnesium Alloy & Key Laboratory of Materials Processing and Mold Technology (Ministry of Education), Zhengzhou University, 100 Science Road, Zhengzhou 450001, PR China
| | - Hang Li
- School of Material Science and Engineering & Henan Key Laboratory of Advanced Magnesium Alloy & Key Laboratory of Materials Processing and Mold Technology (Ministry of Education), Zhengzhou University, 100 Science Road, Zhengzhou 450001, PR China
| | - Yashan Feng
- Zhengzhou Railway Vocational & Technical College, Zhengzhou 450000, China
| | - Jingan Li
- School of Material Science and Engineering & Henan Key Laboratory of Advanced Magnesium Alloy & Key Laboratory of Materials Processing and Mold Technology (Ministry of Education), Zhengzhou University, 100 Science Road, Zhengzhou 450001, PR China..
| | - Shaokang Guan
- School of Material Science and Engineering & Henan Key Laboratory of Advanced Magnesium Alloy & Key Laboratory of Materials Processing and Mold Technology (Ministry of Education), Zhengzhou University, 100 Science Road, Zhengzhou 450001, PR China..
| |
Collapse
|
5
|
Hong Q, Zhou H, Cheng Y, Yang M, Zhang Q, Liu S, Xiong Q, Pan C. Synthesis of Star 6-Arm Polyethylene Glycol-Heparin Copolymer to Construct Anticorrosive and Biocompatible Coating on Magnesium Alloy Surface. Front Bioeng Biotechnol 2022; 10:853487. [PMID: 35223805 PMCID: PMC8865805 DOI: 10.3389/fbioe.2022.853487] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/12/2022] [Accepted: 01/21/2022] [Indexed: 12/01/2022] Open
Abstract
Magnesium alloy has become a research hotspot of the degradable vascular stent materials due to its biodegradability and excellent mechanical properties. However, its rapid degradation rate after implantation and the limited biocompatibility restrict its application in clinic. Constructing a multifunctional bioactive polymer coating on the magnesium alloys represents one of the popular and effective approaches to simultaneously improve the corrosion resistance and biocompatibility. In the present study, the copolymer of 6-arm polyethylene glycol and heparin (PEG-Hep) was successfully synthesized and then immobilized on the surface of chitosan (Chi)-modified magnesium alloy surface through electrostatic interaction to improve the corrosion resistance and biocompatibility. The results of attenuated total reflection Fourier transform infrared spectroscopy (ATR-FTIR), X-ray photoelectron spectroscopy (XPS) and scanning electron microscopy showed that a dense and compact coating was created on the magnesium alloy surface. The coating displayed excellent hydrophilicity. At the same time, the as-prepared coating can significantly not only improve the corrosion potential, reduce the corrosion current and the pH changes of the immersion solution, but also keep a relatively intact surface morphology after immersing in simulated body fluid solution for 14 days, demonstrating that the coating can significantly improve the corrosion resistance of the magnesium alloy. Moreover, the magnesium alloy with PEG-Hep coating exhibited excellent hemocompatibility according to the results of the hemolysis rate and platelet adhesion and activation. In addition, the modified magnesium alloy had a good ability to promote the endothelial cell adhesion and proliferation. Therefore, the PEG-Hep multifunctional coating can be applied in the surface modification of the biodegradable magnesium alloy stent to simultaneously improve the corrosion resistance and biocompatibility.
Collapse
Affiliation(s)
- Qingxiang Hong
- Faculty of Mechanical and Materials Engineering, Jiangsu Provincial Engineering Research Center for Biomaterials and Advanced Medical Devices, Huaiyin Institute of Technology, Huai’an, China
| | - Hualan Zhou
- The Affiliated Huai’an Hospital of Xuzhou Medical University, Huai’an, China
| | - Yuxin Cheng
- Faculty of Mechanical and Materials Engineering, Jiangsu Provincial Engineering Research Center for Biomaterials and Advanced Medical Devices, Huaiyin Institute of Technology, Huai’an, China
| | - Minhui Yang
- Faculty of Mechanical and Materials Engineering, Jiangsu Provincial Engineering Research Center for Biomaterials and Advanced Medical Devices, Huaiyin Institute of Technology, Huai’an, China
| | - Qiuyang Zhang
- Faculty of Mechanical and Materials Engineering, Jiangsu Provincial Engineering Research Center for Biomaterials and Advanced Medical Devices, Huaiyin Institute of Technology, Huai’an, China
| | - Sen Liu
- Faculty of Mechanical and Materials Engineering, Jiangsu Provincial Engineering Research Center for Biomaterials and Advanced Medical Devices, Huaiyin Institute of Technology, Huai’an, China
| | - Qingping Xiong
- Faculty of Chemical Engineering, Huaiyin Institute of Technology, Huai’an, China
| | - Changjiang Pan
- Faculty of Mechanical and Materials Engineering, Jiangsu Provincial Engineering Research Center for Biomaterials and Advanced Medical Devices, Huaiyin Institute of Technology, Huai’an, China
- *Correspondence: Changjiang Pan,
| |
Collapse
|
6
|
Zhang ZQ, Yang YX, Li JA, Zeng RC, Guan SK. Advances in coatings on magnesium alloys for cardiovascular stents - A review. Bioact Mater 2021; 6:4729-4757. [PMID: 34136723 PMCID: PMC8166647 DOI: 10.1016/j.bioactmat.2021.04.044] [Citation(s) in RCA: 51] [Impact Index Per Article: 12.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/08/2021] [Revised: 04/27/2021] [Accepted: 04/27/2021] [Indexed: 12/15/2022] Open
Abstract
Magnesium (Mg) and its alloys, as potential biodegradable materials, have drawn wide attention in the cardiovascular stent field because of their appropriate mechanical properties and biocompatibility. Nevertheless, the occurrence of thrombosis, inflammation, and restenosis of implanted Mg alloy stents caused by their poor corrosion resistance and insufficient endothelialization restrains their anticipated clinical applications. Numerous surface treatment tactics have mainly striven to modify the Mg alloy for inhibiting its degradation rate and enduing it with biological functionality. This review focuses on highlighting and summarizing the latest research progress in functionalized coatings on Mg alloys for cardiovascular stents over the last decade, regarding preparation strategies for metal oxide, metal hydroxide, inorganic nonmetallic, polymer, and their composite coatings; and the performance of these strategies in regulating degradation behavior and biofunction. Potential research direction is also concisely discussed to help guide biological functionalized strategies and inspire further innovations. It is hoped that this review can give assistance to the surface modification of cardiovascular Mg-based stents and promote future advancements in this emerging research field.
Collapse
Affiliation(s)
- Zhao-Qi Zhang
- School of Material Science and Engineering & Henan Key Laboratory of Advanced Magnesium Alloy & Key Laboratory of Materials Processing and Mold Technology (Ministry of Education), Zhengzhou University, 100 Science Road, Zhengzhou, 450001, PR China
| | - Yong-Xin Yang
- School of Material Science and Engineering & Henan Key Laboratory of Advanced Magnesium Alloy & Key Laboratory of Materials Processing and Mold Technology (Ministry of Education), Zhengzhou University, 100 Science Road, Zhengzhou, 450001, PR China
| | - Jing-An Li
- School of Material Science and Engineering & Henan Key Laboratory of Advanced Magnesium Alloy & Key Laboratory of Materials Processing and Mold Technology (Ministry of Education), Zhengzhou University, 100 Science Road, Zhengzhou, 450001, PR China
| | - Rong-Chang Zeng
- Corrosion Laboratory for Light Metals, College of Material Science and Engineering, Shandong University of Science and Technology, Qingdao, 266590, China
| | - Shao-Kang Guan
- School of Material Science and Engineering & Henan Key Laboratory of Advanced Magnesium Alloy & Key Laboratory of Materials Processing and Mold Technology (Ministry of Education), Zhengzhou University, 100 Science Road, Zhengzhou, 450001, PR China
| |
Collapse
|
7
|
Biodegradable stents for coronary artery disease treatment: Recent advances and future perspectives. MATERIALS SCIENCE & ENGINEERING. C, MATERIALS FOR BIOLOGICAL APPLICATIONS 2018; 91:163-178. [DOI: 10.1016/j.msec.2018.04.100] [Citation(s) in RCA: 84] [Impact Index Per Article: 12.0] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/23/2017] [Revised: 04/11/2018] [Accepted: 04/28/2018] [Indexed: 12/24/2022]
|
8
|
Preparation and characterization of controlled heparin release waterborne polyurethane coating systems. CHINESE JOURNAL OF POLYMER SCIENCE 2016. [DOI: 10.1007/s10118-016-1787-3] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/01/2023]
|
9
|
Moore SS, O’Sullivan KJ, Verdecchia F. Shrinking the Supply Chain for Implantable Coronary Stent Devices. Ann Biomed Eng 2015; 44:497-507. [DOI: 10.1007/s10439-015-1471-8] [Citation(s) in RCA: 20] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/21/2015] [Accepted: 09/24/2015] [Indexed: 12/13/2022]
|
10
|
Yang Y, Qi P, Yang Z, Huang N. Nitric oxide based strategies for applications of biomedical devices. BIOSURFACE AND BIOTRIBOLOGY 2015. [DOI: 10.1016/j.bsbt.2015.08.003] [Citation(s) in RCA: 34] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/23/2022] Open
|
11
|
Qi P, Yan W, Yang Y, Li Y, Fan Y, Chen J, Yang Z, Tu Q, Huang N. Immobilization of DNA aptamers via plasma polymerized allylamine film to construct an endothelial progenitor cell-capture surface. Colloids Surf B Biointerfaces 2014; 126:70-9. [PMID: 25575347 DOI: 10.1016/j.colsurfb.2014.12.001] [Citation(s) in RCA: 36] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/09/2014] [Revised: 11/25/2014] [Accepted: 12/01/2014] [Indexed: 02/06/2023]
Abstract
The endothelial progenitor cells (EPCs) capture stent has drawn increasing attentions and become one of the most promising concepts for the next generation vascular stent. In this regard, it is of great significance to immobilize a molecule with the ability to bind EPC for rapid in vivo endothelialization with high specificity. In this work, a facile two-step method aimed at constructing a coating with specific EPC capturing aptamers is reported. The processes involves as the first-step deposition of plasma polymerized allylamine (PPAam) on a substrate to introduce amine groups, followed by the electrostatic adsorption of a 34 bases single strand DNA sequence to the PPAam surface as a second step (PPAam-DNA). Grazing incidence attenuated total reflection Fourier transform infrared spectroscopy (GATR-FTIR) and X-ray photoelectron spectroscopy (XPS) confirmed the successful immobilization of the aptamers. Quartz crystal microbalance with dissipation (QCM-D) real time monitoring result shows that about 175 ng/cm(2) aptamers were conjugated onto the PPAam surface. The interactions between the modified surfaces and human umbilical vein endothelial cells (ECs), smooth muscle cells (SMCs), and murine induced EPCs derived from mesenchymal stem cells (MSCs) were also investigated. It was demonstrated that PPAam-DNA samples could capture more EPCs, and present a cellular friendly surface for the proliferation of both EPCs and ECs but no effect on the hyperplasia of SMCs. Also, the co-culture results of 3 types of cells confirmed that the aptamer could specifically bond EPCs rather than ECs and SMCs, suggesting the competitive adhesion advantage of EPCs to ECs and SMCs. These data demonstrate that the EPC aptamer has large potential for designing an EPC captured stent and other vascular grafts with targeted in situ endothelialization.
Collapse
Affiliation(s)
- Pengkai Qi
- Key Lab of Advanced Technology of Materials of Education Ministry, Southwest Jiaotong University, Chengdu 610031, China; School of Materials Science and Engineering, Southwest Jiaotong University, Chengdu 610031, China
| | - Wei Yan
- Key Lab of Advanced Technology of Materials of Education Ministry, Southwest Jiaotong University, Chengdu 610031, China; School of Materials Science and Engineering, Southwest Jiaotong University, Chengdu 610031, China
| | - Ying Yang
- Key Lab of Advanced Technology of Materials of Education Ministry, Southwest Jiaotong University, Chengdu 610031, China; School of Materials Science and Engineering, Southwest Jiaotong University, Chengdu 610031, China
| | - Yalong Li
- Key Lab of Advanced Technology of Materials of Education Ministry, Southwest Jiaotong University, Chengdu 610031, China; Laboratory of Biosensing and MicroMechatronics, Southwest Jiaotong University, Chengdu 610031, China
| | - Yi Fan
- Key Lab of Advanced Technology of Materials of Education Ministry, Southwest Jiaotong University, Chengdu 610031, China; School of Life Science and Engineering, Southwest Jiaotong University, Chengdu 610031, China
| | - Junying Chen
- Key Lab of Advanced Technology of Materials of Education Ministry, Southwest Jiaotong University, Chengdu 610031, China; School of Materials Science and Engineering, Southwest Jiaotong University, Chengdu 610031, China
| | - Zhilu Yang
- Key Lab of Advanced Technology of Materials of Education Ministry, Southwest Jiaotong University, Chengdu 610031, China; School of Materials Science and Engineering, Southwest Jiaotong University, Chengdu 610031, China.
| | - Qiufen Tu
- Key Lab of Advanced Technology of Materials of Education Ministry, Southwest Jiaotong University, Chengdu 610031, China; Laboratory of Biosensing and MicroMechatronics, Southwest Jiaotong University, Chengdu 610031, China.
| | - Nan Huang
- Key Lab of Advanced Technology of Materials of Education Ministry, Southwest Jiaotong University, Chengdu 610031, China; School of Materials Science and Engineering, Southwest Jiaotong University, Chengdu 610031, China.
| |
Collapse
|
12
|
New strategies for developing cardiovascular stent surfaces with novel functions (Review). Biointerphases 2014; 9:029017. [DOI: 10.1116/1.4878719] [Citation(s) in RCA: 17] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022] Open
|