1
|
Lyu C, Guo S, Zhou W, Yan Y, Yang C, Wang Y, Meng F. A Deep-Learning-Based Guidewire Compliant Control Method for the Endovascular Surgery Robot. MICROMACHINES 2022; 13:mi13122237. [PMID: 36557535 PMCID: PMC9788084 DOI: 10.3390/mi13122237] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/17/2022] [Revised: 12/08/2022] [Accepted: 12/13/2022] [Indexed: 05/14/2023]
Abstract
Endovascular surgery is a high-risk operation with limited vision and intractable guidewires. At present, endovascular surgery robot (ESR) systems based on force feedback liberates surgeons' operation skills, but it lacks the ability to combine force perception with vision. In this study, a deep learning-based guidewire-compliant control method (GCCM) is proposed, which guides the robot to avoid surgical risks and improve the efficiency of guidewire operation. First, a deep learning-based model called GCCM-net is built to identify whether the guidewire tip collides with the vascular wall in real time. The experimental results in a vascular phantom show that the best accuracy of GCCM-net is 94.86 ± 0.31%. Second, a real-time operational risk classification method named GCCM-strategy is proposed. When the surgical risks occur, the GCCM-strategy uses the result of GCCM-net as damping and decreases the robot's running speed through virtual resistance. Compared with force sensors, the robot with GCCM-strategy can alleviate the problem of force position asynchrony caused by the long and soft guidewires in real-time. Experiments run by five guidewire operators show that the GCCM-strategy can reduce the average operating force by 44.0% and shorten the average operating time by 24.6%; therefore the combination of vision and force based on deep learning plays a positive role in improving the operation efficiency in ESR.
Collapse
Affiliation(s)
- Chuqiao Lyu
- School of Life Science, Beijing Institute of Technology, Beijing 100081, China
| | - Shuxiang Guo
- School of Life Science, Beijing Institute of Technology, Beijing 100081, China
- Correspondence: ; Tel.: +86-186-0020-0326
| | - Wei Zhou
- Department of Mechanical Engineering, Tsinghua University, Beijing 100084, China
| | - Yonggan Yan
- School of Life Science, Beijing Institute of Technology, Beijing 100081, China
| | - Chenguang Yang
- School of Life Science, Beijing Institute of Technology, Beijing 100081, China
| | - Yue Wang
- School of Life Science, Beijing Institute of Technology, Beijing 100081, China
| | - Fanxu Meng
- School of Life Science, Beijing Institute of Technology, Beijing 100081, China
| |
Collapse
|
2
|
Condino S, Piazza R, Carbone M, Bath J, Troisi N, Ferrari M, Berchiolli R. Bioengineering, augmented reality, and robotic surgery in vascular surgery: A literature review. Front Surg 2022; 9:966118. [PMID: 36061062 PMCID: PMC9437582 DOI: 10.3389/fsurg.2022.966118] [Citation(s) in RCA: 11] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/10/2022] [Accepted: 08/04/2022] [Indexed: 12/20/2022] Open
Abstract
Biomedical engineering integrates a variety of applied sciences with life sciences to improve human health and reduce the invasiveness of surgical procedures. Technological advances, achieved through biomedical engineering, have contributed to significant improvements in the field of vascular and endovascular surgery. This paper aims to review the most cutting-edge technologies of the last decade involving the use of augmented reality devices and robotic systems in vascular surgery, highlighting benefits and limitations. Accordingly, two distinct literature surveys were conducted through the PubMed database: the first review provides a comprehensive assessment of augmented reality technologies, including the different techniques available for the visualization of virtual content (11 papers revised); the second review collects studies with bioengineering content that highlight the research trend in robotic vascular surgery, excluding works focused only on the clinical use of commercially available robotic systems (15 papers revised). Technological flow is constant and further advances in imaging techniques and hardware components will inevitably bring new tools for a clinical translation of innovative therapeutic strategies in vascular surgery.
Collapse
Affiliation(s)
- Sara Condino
- Department of Information Engineering, University of Pisa, Pisa, Italy
- EndoCAS Center, Department of Translational Research and New Technologies in Medicine and Surgery, University of Pisa, Pisa, Italy
| | - Roberta Piazza
- EndoCAS Center, Department of Translational Research and New Technologies in Medicine and Surgery, University of Pisa, Pisa, Italy
| | - Marina Carbone
- Department of Information Engineering, University of Pisa, Pisa, Italy
- EndoCAS Center, Department of Translational Research and New Technologies in Medicine and Surgery, University of Pisa, Pisa, Italy
- Correspondence: Marina Carbone
| | - Jonathan Bath
- Division of Vascular Surgery, University of Missouri, Columbia, MO, United States
| | - Nicola Troisi
- Vascular Surgery Unit, Department of Translational Research and New Technologies in Medicine and Surgery, University of Pisa, Pisa, Italy
| | - Mauro Ferrari
- Vascular Surgery Unit, Department of Translational Research and New Technologies in Medicine and Surgery, University of Pisa, Pisa, Italy
| | - Raffaella Berchiolli
- Vascular Surgery Unit, Department of Translational Research and New Technologies in Medicine and Surgery, University of Pisa, Pisa, Italy
| |
Collapse
|
3
|
Zhao Y, Mei Z, Luo X, Mao J, Zhao Q, Liu G, Wu D. Remote vascular interventional surgery robotics: a literature review. Quant Imaging Med Surg 2022; 12:2552-2574. [PMID: 35371939 PMCID: PMC8923856 DOI: 10.21037/qims-21-792] [Citation(s) in RCA: 17] [Impact Index Per Article: 5.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/09/2021] [Accepted: 12/22/2021] [Indexed: 07/25/2023]
Abstract
Vascular interventional doctors are exposed to radiation hazards during surgery and endure high work intensity. Remote vascular interventional surgery robotics is a hot research field, in which researchers aim to not only protect the health of interventional doctors, but to also improve surgical accuracy and efficiency. However, the current vascular interventional robots have numerous shortcomings, such as poor haptic feedback, few compatible surgeries and instruments, and cumbersome maintenance and operational procedures. Nevertheless, vascular interventional surgery combined with robotics provides more cutting-edge directions, such as Internet remote surgery combined with 5G network technology and the application of artificial intelligence in surgical procedures. To summarize the developmental status and key technical points of intravascular interventional surgical robotics research, we performed a systematic literature search to retrieve original articles related to remote vascular interventional surgery robotics published up to December 2020. This review, which includes 113 articles published in English, introduces the mechanical and structural characteristics of various aspects of vascular interventional surgical robotics, discusses the current key features of vascular interventional surgical robotics in force sensing, haptic feedback, and control methods, and summarizes current frontiers in autonomous surgery, long-distance robotic telesurgery, and magnetic resonance imaging (MRI)-compatible structures. On the basis of summarizing the current research status of remote vascular interventional surgery robotics, we aim to propose a variety of prospects for future robotic systems.
Collapse
Affiliation(s)
- Yang Zhao
- Department of Mechanical & Electrical Engineering, Xiamen University, Xiamen, China
| | - Ziyang Mei
- Department of Mechanical & Electrical Engineering, Xiamen University, Xiamen, China
| | - Xiaoxiao Luo
- Department of Mechanical & Electrical Engineering, Xiamen University, Xiamen, China
| | - Jingsong Mao
- Department of Radiology, Xiang’an Hospital of Xiamen University, Xiamen, China
| | - Qingliang Zhao
- State Key Laboratory of Molecular Vaccinology and Molecular Diagnostics Center for Molecular Imaging and Translational Medicine, School of Public Health, Xiamen University, Xiamen, China
| | - Gang Liu
- State Key Laboratory of Molecular Vaccinology and Molecular Diagnostics Center for Molecular Imaging and Translational Medicine, School of Public Health, Xiamen University, Xiamen, China
| | - Dezhi Wu
- Department of Mechanical & Electrical Engineering, Xiamen University, Xiamen, China
| |
Collapse
|
4
|
Yang C, Guo S, Bao X. An Isomorphic Interactive Device for the Interventional Surgical Robot after In Vivo Study. MICROMACHINES 2022; 13:mi13010111. [PMID: 35056276 PMCID: PMC8778927 DOI: 10.3390/mi13010111] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 12/14/2021] [Revised: 01/04/2022] [Accepted: 01/10/2022] [Indexed: 02/04/2023]
Abstract
Interventional surgical robots are widely used in neurosurgery to improve surgeons’ working environment and surgical safety. Based on the actual operational needs of surgeons’ feedback during preliminary in vivo experiments, this paper proposed an isomorphic interactive master controller for the master–slave interventional surgical robot. The isomorphic design of the controller allows surgeons to utilize their surgical skills during remote interventional surgeries. The controller uses the catheter and guidewire as the operating handle, the same as during actual surgeries. The collaborative operational structure design and the working methods followed the clinical operational skills. The linear force feedback and torque feedback devices were designed to improve the safety of surgeries under remote operating conditions. An eccentric force compensation was conducted to achieve accurate force feedback. Several experiments were carried out, such as calibration experiments, master–slave control performance evaluation experiments, and operation comparison experiments on the novel and previously used controllers. The experimental results show that the proposed controller can perform complex operations in remote surgery applications and has the potential for further animal experiment evaluations.
Collapse
Affiliation(s)
- Cheng Yang
- School of Automation, Beijing Institute of Technology, Beijing 100081, China;
- Key Laboratory of Convergence Biomedical Engineering System and Healthcare Technology, The Ministry of Industry and Information Technology, Beijing Institute of Technology, Beijing 100081, China
| | - Shuxiang Guo
- School of Automation, Beijing Institute of Technology, Beijing 100081, China;
- Key Laboratory of Convergence Biomedical Engineering System and Healthcare Technology, The Ministry of Industry and Information Technology, Beijing Institute of Technology, Beijing 100081, China
- Faculty of Engineering, Kagawa University, 2217-20 Hayashi-cho, Takamatsu 760-8521, Japan
- Correspondence: (S.G.); (X.B.)
| | - Xianqiang Bao
- Key Laboratory of Convergence Biomedical Engineering System and Healthcare Technology, The Ministry of Industry and Information Technology, Beijing Institute of Technology, Beijing 100081, China
- Correspondence: (S.G.); (X.B.)
| |
Collapse
|
5
|
Zhou W, Guo S, Guo J, Meng F, Chen Z. ADRC-Based Control Method for the Vascular Intervention Master-Slave Surgical Robotic System. MICROMACHINES 2021; 12:mi12121439. [PMID: 34945289 PMCID: PMC8707856 DOI: 10.3390/mi12121439] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 11/04/2021] [Revised: 11/20/2021] [Accepted: 11/23/2021] [Indexed: 12/25/2022]
Abstract
In vascular interventional surgery, surgeons operate guidewires and catheters to diagnose and treat patients with the assistance of the digital subtraction angiography (DSA). Therefore, the surgeon will be exposed to X-rays for extended periods. To protect the surgeon, the development of a robot-assisted surgical system is of great significance. The displacement tracking accuracy is the most important issue to be considered in the development of the system. In this study, the active disturbance rejection control (ADRC) method is applied to guarantee displacement tracking accuracy. First, the core contents of the proportional–integral–derivative (PID) and ADRC methods are analyzed. Second, comparative evaluation experiments for incremental PID and ADRC methods are presented. The results show that the ADRC method has better performance of than that of the incremental PID method. Finally, the calibration experiments for the ADRC control method are implemented using the master–slave robotic system. These experiments demonstrate that the maximum tracking error is 0.87 mm using the ADRC method, effectively guaranteeing surgical safety.
Collapse
Affiliation(s)
- Wei Zhou
- School of Life Science, Beijing Institute of Technology, Beijing 100081, China; (W.Z.); (F.M.); (Z.C.)
| | - Shuxiang Guo
- School of Life Science, Beijing Institute of Technology, Beijing 100081, China; (W.Z.); (F.M.); (Z.C.)
- Key Laboratory of Convergence Medical Engineering System and Healthcare Technology, Ministry of Industry and Information Technology, School of Life Science, Beijing Institute of Technology, Beijing 100081, China
- Faculty of Engineering, Kagawa University, 2217-20 Hayashi-cho, Takamatsu 760-8521, Japan
- Correspondence: (S.G.); (J.G.); Tel.: +86-186-0020-0326 (S.G.)
| | - Jin Guo
- School of Life Science, Beijing Institute of Technology, Beijing 100081, China; (W.Z.); (F.M.); (Z.C.)
- Correspondence: (S.G.); (J.G.); Tel.: +86-186-0020-0326 (S.G.)
| | - Fanxu Meng
- School of Life Science, Beijing Institute of Technology, Beijing 100081, China; (W.Z.); (F.M.); (Z.C.)
| | - Zhengyang Chen
- School of Life Science, Beijing Institute of Technology, Beijing 100081, China; (W.Z.); (F.M.); (Z.C.)
| |
Collapse
|
6
|
Ahn J, Kim J, Lee H, Hwang M, Kwon DS. A highly intuitive and ergonomic redundant joint master device for four-degrees of freedom flexible endoscopic surgery robot. Int J Med Robot 2020; 17:1-14. [PMID: 32794625 DOI: 10.1002/rcs.2147] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/26/2020] [Revised: 07/27/2020] [Accepted: 07/28/2020] [Indexed: 01/16/2023]
Abstract
BACKGROUND Studies have been conducted on slave-specific master devices with a similar kinematic structure to the slave to enhance intuitiveness. However, for the four-degrees of freedom (DOFs) slave of a flexible endoscopic surgery robot, only four DOFs in the master device causes low ergonomic performance. METHODS To enhance ergonomic performance, a second yaw joint was added as a redundant joint after considering the range of wrist motion and the workspace shape. Three experiments were performed to compare the intuitiveness and ergonomic performance of the proposed device with four-DOFs slave-specific and six-DOFs general-purpose master devices. RESULTS Significant differences were observed in terms of intuitiveness performance between the slave-specific and the general-purposed master device. On the other hand, there was no significant difference in ergonomic performance between the master devices with redundant joint. CONCLUSIONS Compared with a general-purpose master device, the proposed one exhibited noticeably improved intuitiveness performance and comparable ergonomic performance.
Collapse
Affiliation(s)
- Jeongdo Ahn
- Department of Mechanical Engineering, Korea Advanced Institute of Science and Technology (KAIST), Daejeon, Republic of Korea
| | - Joonhwan Kim
- Department of Mechanical Engineering, Korea Advanced Institute of Science and Technology (KAIST), Daejeon, Republic of Korea
| | - Hyunyoung Lee
- Department of Mechanical Engineering, Korea Advanced Institute of Science and Technology (KAIST), Daejeon, Republic of Korea
| | - Minho Hwang
- Department of Electrical Engineering and Computer Sciences, University of California Berkeley, Berkeley, California, USA
| | - Dong-Soo Kwon
- Department of Mechanical Engineering, Korea Advanced Institute of Science and Technology (KAIST), Daejeon, Republic of Korea
| |
Collapse
|