1
|
Moon S, Kang J, Kim Y, Jo E, Jeong P, Roh Y, Baek J. Carbon nanotube-based multiple source C-arm CT system: feasibility study with prototype system. OPTICS EXPRESS 2023; 31:44772-44797. [PMID: 38178538 DOI: 10.1364/oe.503421] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/23/2023] [Accepted: 12/07/2023] [Indexed: 01/06/2024]
Abstract
To extend the field of view while reducing dimensions of the C-arm, we propose a carbon nanotube (CNT)-based C-arm computed tomography (CT) system with multiple X-ray sources. A prototype system was developed using three CNT X-ray sources, enabling a feasibility study. Geometry calibration and image reconstruction were performed to improve the quality of image acquisition. However, the geometry of the prototype system led to projection truncation for each source and an overlap region of object area covered by each source in the two-dimensional Radon space, necessitating specific corrective measures. We addressed these problems by implementing truncation correction and applying weighting techniques to the overlap region during the image reconstruction phase. Furthermore, to enable image reconstruction with a scan angle less than 360°, we designed a weighting function to solve data redundancy caused by the short scan angle. The accuracy of the geometry calibration method was evaluated via computer simulations. We also quantified the improvements in reconstructed image quality using mean-squared error and structural similarity. Moreover, detector lag correction was applied to address the afterglow observed in the experimental data obtained from the prototype system. Our evaluation of image quality involved comparing reconstructed images obtained with and without incorporating the geometry calibration results and images with and without lag correction. The outcomes of our simulation study and experimental investigation demonstrated the efficacy of our proposed geometry calibration, image reconstruction method, and lag correction in reducing image artifacts.
Collapse
|
2
|
Sahovaler A, Daly MJ, Chan HHL, Nayak P, Tzelnick S, Arkhangorodsky M, Qiu J, Weersink R, Irish JC, Ferguson P, Wunder JS. Automatic Registration and Error Color Maps to Improve Accuracy for Navigated Bone Tumor Surgery Using Intraoperative Cone-Beam CT. JB JS Open Access 2022; 7:JBJSOA-D-21-00140. [PMID: 35540727 PMCID: PMC9071254 DOI: 10.2106/jbjs.oa.21.00140] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/14/2022] Open
Abstract
Computer-assisted surgery (CAS) can improve surgical precision in orthopaedic oncology. Accurate alignment of the patient’s imaging coordinates with the anatomy, known as registration, is one of the most challenging aspects of CAS and can be associated with substantial error. Using intraoperative, on-the-table, cone-beam computed tomography (CBCT), we performed a pilot clinical study to validate a method for automatic intraoperative registration.
Collapse
Affiliation(s)
- Axel Sahovaler
- Guided Therapeutics (GTx) Program, TECHNA Institute, University Health Network, Toronto, Ontario, Canada
- Head & Neck Surgery Unit, University College London Hospitals, London, United Kingdom
| | - Michael J Daly
- Guided Therapeutics (GTx) Program, TECHNA Institute, University Health Network, Toronto, Ontario, Canada
| | - Harley H L Chan
- Guided Therapeutics (GTx) Program, TECHNA Institute, University Health Network, Toronto, Ontario, Canada
| | - Prakash Nayak
- Guided Therapeutics (GTx) Program, TECHNA Institute, University Health Network, Toronto, Ontario, Canada
- Department of Surgical Oncology, Bone and Soft Tissue Disease Management Group, Tata Memorial Centre, Mumbai, India
- Division of Orthopaedic Surgery, Department of Surgery, University of Toronto, Toronto, Ontario, Canada
- University of Toronto Musculoskeletal Oncology Unit, Mount Sinai Hospital, Toronto, Ontario, Canada
| | - Sharon Tzelnick
- Guided Therapeutics (GTx) Program, TECHNA Institute, University Health Network, Toronto, Ontario, Canada
| | - Michelle Arkhangorodsky
- Guided Therapeutics (GTx) Program, TECHNA Institute, University Health Network, Toronto, Ontario, Canada
| | - Jimmy Qiu
- Guided Therapeutics (GTx) Program, TECHNA Institute, University Health Network, Toronto, Ontario, Canada
| | - Robert Weersink
- Guided Therapeutics (GTx) Program, TECHNA Institute, University Health Network, Toronto, Ontario, Canada
| | - Jonathan C Irish
- Guided Therapeutics (GTx) Program, TECHNA Institute, University Health Network, Toronto, Ontario, Canada
| | - Peter Ferguson
- Guided Therapeutics (GTx) Program, TECHNA Institute, University Health Network, Toronto, Ontario, Canada
- Division of Orthopaedic Surgery, Department of Surgery, University of Toronto, Toronto, Ontario, Canada
- University of Toronto Musculoskeletal Oncology Unit, Mount Sinai Hospital, Toronto, Ontario, Canada
| | - Jay S Wunder
- Guided Therapeutics (GTx) Program, TECHNA Institute, University Health Network, Toronto, Ontario, Canada
- Division of Orthopaedic Surgery, Department of Surgery, University of Toronto, Toronto, Ontario, Canada
- University of Toronto Musculoskeletal Oncology Unit, Mount Sinai Hospital, Toronto, Ontario, Canada
| |
Collapse
|
3
|
Zhao C, Herbst M, Weber T, Luckner C, Vogt S, Ritschl L, Kappler S, Siewerdsen JH, Zbijewski W. Slot-scan dual-energy bone densitometry using motorized X-ray systems. Med Phys 2021; 48:6673-6695. [PMID: 34628651 DOI: 10.1002/mp.15272] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/06/2021] [Revised: 08/31/2021] [Accepted: 09/24/2021] [Indexed: 11/12/2022] Open
Abstract
PURPOSE We investigate the feasibility of slot-scan dual-energy (DE) bone densitometry on motorized radiographic equipment. This approach will enable fast quantitative measurements of areal bone mineral density (aBMD) for opportunistic evaluation of osteoporosis. METHODS We investigated DE slot-scan protocols to obtain aBMD measurements at the lumbar spine (L-spine) and hip using a motorized x-ray platform capable of synchronized translation of the x-ray source and flat-panel detector (FPD). The slot dimension was 5 × 20 cm2 . The DE slot views were processed as follows: (1) convolution kernel-based scatter correction, (2) unfiltered backprojection to tile the slots into long-length radiographs, and (3) projection-domain DE decomposition, consisting of an initial adipose-water decomposition in a bone-free region followed by water-CaHA decomposition with adjustment for adipose content. The accuracy and reproducibility of slot-scan aBMD measurements were investigated using a high-fidelity simulator of a robotic x-ray system (Siemens Multitom Rax) in a total of 48 body phantom realizations: four average bone density settings (cortical bone mass fraction: 10-40%), four body sizes (waist circumference, WC = 70-106 cm), and three lateral shifts of the body within the slot field of view (FOV) (centered and ±1 cm off-center). Experimental validations included: (1) x-ray test-bench feasibility study of adipose-water decomposition and (2) initial demonstration of slot-scan DE bone densitometry on the robotic x-ray system using the European Spine Phantom (ESP) with added attenuation (polymethyl methacrylate [PMMA] slabs) ranging 2 to 6 cm thick. RESULTS For the L-spine, the mean aBMD error across all WC settings ranged from 0.08 g/cm2 for phantoms with average cortical bone fraction wcortical = 10% to ∼0.01 g/cm2 for phantoms with wcortical = 40%. The L-spine aBMD measurements were fairly robust to changes in body size and positioning, e.g., coefficient of variation (CV) for L1 with wcortical = 30% was ∼0.034 for various WC and ∼0.02 for an obese patient (WC = 106 cm) changing lateral shift. For the hip, the mean aBMD error across all phantom configurations was about 0.07 g/cm2 for a centered patient. The reproducibility of hip aBMD was slightly worse than in the L-spine (e.g., in the femoral neck, the CV with respect to changing WC was ∼0.13 for phantom realizations with wcortical = 30%) due to more challenging scatter estimation in the presence of an air-tissue interface within the slot FOV. The aBMD of the hip was therefore sensitive to lateral positioning of the patient, especially for obese patients: e.g., the CV with respect to patient lateral shift for femoral neck with WC = 106 cm and wcortical = 30% was 0.14. Empirical evaluations confirmed substantial reduction in aBMD errors with the proposed adipose estimation procedure and demonstrated robust aBMD measurements on the robotic x-ray system, with aBMD errors of ∼0.1 g/cm2 across all three simulated ESP vertebrae and all added PMMA attenuator settings. CONCLUSIONS We demonstrated that accurate aBMD measurements can be obtained on a motorized FPD-based x-ray system using DE slot-scans with kernel-based scatter correction, backprojection-based slot view tiling, and DE decomposition with adipose correction.
Collapse
Affiliation(s)
- Chumin Zhao
- Department of Biomedical Engineering, Johns Hopkins University, Baltimore, Maryland, USA
| | | | | | | | | | | | | | - Jeffrey H Siewerdsen
- Department of Biomedical Engineering, Johns Hopkins University, Baltimore, Maryland, USA.,Department of Radiology, Johns Hopkins University, Baltimore, Maryland, USA
| | - Wojciech Zbijewski
- Department of Biomedical Engineering, Johns Hopkins University, Baltimore, Maryland, USA
| |
Collapse
|
4
|
Zhao C, Herbst M, Vogt S, Ritschl L, Kappler S, Siewerdsen JH, Zbijewski W. Cone-beam imaging with tilted rotation axis: Method and performance evaluation. Med Phys 2020; 47:3305-3320. [PMID: 32340069 DOI: 10.1002/mp.14209] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/21/2019] [Revised: 02/26/2020] [Accepted: 04/13/2020] [Indexed: 01/07/2023] Open
Abstract
PURPOSE The recently introduced robotic x-ray systems provide the flexibility to acquire cone-beam computed tomography (CBCT) data using customized, application-specific source-detector trajectories. We exploit this capability to mitigate the effects of x-ray scatter and noise in CBCT imaging of weight-bearing foot and cervical spine (C-spine) using scan orbits with a tilted rotation axis. METHODS We used an advanced CBCT simulator implementing accurate models of x-ray scatter, primary attenuation, and noise to investigate the effects of the orbital tilt angle in upright foot and C-spine imaging. The system model was parameterized using a laboratory version of a three-dimensional (3D) robotic x-ray system (Multitom RAX, Siemens Healthineers). We considered a generalized tilted axis scan configuration, where the detector remained parallel to patient's long body axis during the acquisition, but the elevation of source and detector was changing. A modified Feldkamp-Davis-Kress (FDK) algorithm was developed for reconstruction in this configuration, which departs from the FDK assumption of a detector that is perpendicular to the scan plane. The simulated foot scans involved source-detector distance (SDD) of 1386 mm, orbital tilt angles ranging 10° to 40°, and 400 views at 1 mAs/view and 0.5° increment; the C-spine scans involved -25° to -45° tilt angles, SDD of 1090 mm, and 202 views at 1.3 mAs and 1° increment The imaging performance was assessed by projection-domain measurements of the scatter-to-primary ratio (SPR) and by reconstruction-domain measurements of contrast, noise and generalized contrast-to-noise ratio (gCNR, accounting for both image noise and background nonuniformity) of the metatarsals (foot imaging) and cervical vertebrae (spine imaging). The effects of scatter correction were also compared for horizontal and tilted scans using an ideal Monte Carlo (MC)-based scatter correction and a frame-by-frame mean scatter correction. RESULTS The proposed modified FDK, involving projection resampling, mitigated streak artifacts caused by the misalignment between the filtering direction and the detector rows. For foot imaging (no grids), an optimized 20° tilted orbit reduced the maximum SPR from ~1.5 in a horizontal scan to <0.5. The gCNR of the second metatarsal was enhanced twofold compared to a horizontal orbit. For the C-spine (with vertical grids), imaging with a tilted orbit avoided highly attenuating x-ray paths through the lower cervical vertebrae and shoulders. A -35° tilted orbit yielded improved image quality and visualization of the lower cervical spine: the SPR of lower cervical vertebrae was reduced from ~10 (horizontal orbit) to <6 (tilted orbit), and the gCNR for C5-C7 increased by a factor of 2. Furthermore, tilted orbits showed potential benefits over horizontal orbits by enabling scatter correction with a simple frame-by-frame mean correction without substantial increase in noise-induced artifacts after the correction. CONCLUSIONS Tilted scan trajectories, enabled by the emerging robotic x-ray system technology, were optimized for CBCT imaging of foot and cervical spine using an advanced simulation framework. The results demonstrated the potential advantages of tilted axis orbits in mitigation of scatter artifacts and improving contrast-to-noise ratio in CBCT reconstructions.
Collapse
Affiliation(s)
- Chumin Zhao
- Department of Biomedical Engineering, Johns Hopkins University, Baltimore, MD, 21205, USA
| | | | | | | | | | - Jeffrey H Siewerdsen
- Department of Biomedical Engineering, Johns Hopkins University, Baltimore, MD, 21205, USA.,Russell H. Morgan Department of Radiology, Johns Hopkins University, Baltimore, MD, 21287, USA
| | - Wojciech Zbijewski
- Department of Biomedical Engineering, Johns Hopkins University, Baltimore, MD, 21205, USA
| |
Collapse
|
5
|
Tonetti J, Boudissa M, Kerschbaumer G, Seurat O. Role of 3D intraoperative imaging in orthopedic and trauma surgery. Orthop Traumatol Surg Res 2020; 106:S19-S25. [PMID: 31734181 DOI: 10.1016/j.otsr.2019.05.021] [Citation(s) in RCA: 44] [Impact Index Per Article: 8.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/29/2019] [Revised: 05/03/2019] [Accepted: 05/09/2019] [Indexed: 02/02/2023]
Abstract
Intraoperative three-dimensional (3D) imaging is now feasible because of recent technological advances such as 3D cone-beam CT (CBCT) and flat-panel X-ray detectors (FPDs). These technologies reduce the radiation dose to the patient and surgical team. The aim of this study is to review the advantages of 3D intraoperative imaging in orthopedic and trauma surgery by answering the following 5 questions: What are its technical principles? CBCT with a FPD produces non-distorted digital images and frees up the surgical field. The high quality of these 3D intraoperative images allows them to be integrated into surgical navigation systems. Human-robot comanipulation will likely follow soon after. Conventional multislice CT technology has also improved to the point where it can be used in the operating room. What can we expect from 3D intraoperative imaging and which applications have been validated clinically? We reviewed the literature on this topic for the past 10 years. The expected benefits were determined during the implantation of pedicular screws: more accurate implantation, fewer surgical revisions and time savings. There are few studies in trauma or arthroplasty cases, as robotic comanipulation is a more recent development. What is the tolerance for irradiation to the patient and surgical team? The health drawbacks are the harmful radiation-induced effects. The deterministic effects that we will develop are correlated to the absorbed dose in Gray units (Gy). The stochastic and carcinogenic effects are related to the effective dose in milliSievert (mSv) of linear evolution without threshold. The International Commission on Radiological Protection (ICRP) states that irradiation for medical purposes with risk of detriment is acceptable if it is justified by an optimization attempt. The radioprotection limits must be known but do not constitute opposable restrictions. The superiority of intraoperative 3D imaging over fluoroscopy has been demonstrated for spine surgery and sacroiliac screw fixation. How does the environment need to be adapted? The volume, access, wall protection and floor strength of the operating room must take into account the features of each machine. The instrumentation implants and need for specialized staff result in additional costs. Not every system can track movements during the CBCT acquisition thus transient suspension of assisted ventilation may be required. Is it financially viable? This needs to be calculated based on the expected clinical benefits, which mainly correspond to the elimination of expenses tied to surgical revisions. Our society's search for safety has driven the investments in this technology. LEVEL OF EVIDENCE: V, Expert opinion.
Collapse
Affiliation(s)
- Jérôme Tonetti
- Clinique universitaire de chirurgie orthopédique et traumatologie, hôpital Michallon, CS 10217, 38043 Grenoble cedex 09, France.
| | - Mehdi Boudissa
- Clinique universitaire de chirurgie orthopédique et traumatologie, hôpital Michallon, CS 10217, 38043 Grenoble cedex 09, France
| | - Gael Kerschbaumer
- Clinique universitaire de chirurgie orthopédique et traumatologie, hôpital Michallon, CS 10217, 38043 Grenoble cedex 09, France
| | - Olivier Seurat
- Clinique universitaire de chirurgie orthopédique et traumatologie, hôpital Michallon, CS 10217, 38043 Grenoble cedex 09, France
| |
Collapse
|
6
|
Automatic lumbar vertebrae detection based on feature fusion deep learning for partial occluded C-arm X-ray images. ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. ANNUAL INTERNATIONAL CONFERENCE 2017; 2016:647-650. [PMID: 28268411 DOI: 10.1109/embc.2016.7590785] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/10/2022]
Abstract
Automatic and accurate lumbar vertebrae detection is an essential step of image-guided minimally invasive spine surgery (IG-MISS). However, traditional methods still require human intervention due to the similarity of vertebrae, abnormal pathological conditions and uncertain imaging angle. In this paper, we present a novel convolutional neural network (CNN) model to automatically detect lumbar vertebrae for C-arm X-ray images. Training data is augmented by DRR and automatic segmentation of ROI is able to reduce the computational complexity. Furthermore, a feature fusion deep learning (FFDL) model is introduced to combine two types of features of lumbar vertebrae X-ray images, which uses sobel kernel and Gabor kernel to obtain the contour and texture of lumbar vertebrae, respectively. Comprehensive qualitative and quantitative experiments demonstrate that our proposed model performs more accurate in abnormal cases with pathologies and surgical implants in multi-angle views.
Collapse
|