1
|
Huflage H, Kunz AS, Hendel R, Kraft J, Weick S, Razinskas G, Sauer ST, Pennig L, Bley TA, Grunz JP. Obesity-Related Pitfalls of Virtual versus True Non-Contrast Imaging-An Intraindividual Comparison in 253 Oncologic Patients. Diagnostics (Basel) 2023; 13:diagnostics13091558. [PMID: 37174949 PMCID: PMC10177533 DOI: 10.3390/diagnostics13091558] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/14/2023] [Revised: 04/17/2023] [Accepted: 04/24/2023] [Indexed: 05/15/2023] Open
Abstract
OBJECTIVES Dual-source dual-energy CT (DECT) facilitates reconstruction of virtual non-contrast images from contrast-enhanced scans within a limited field of view. This study evaluates the replacement of true non-contrast acquisition with virtual non-contrast reconstructions and investigates the limitations of dual-source DECT in obese patients. MATERIALS AND METHODS A total of 253 oncologic patients (153 women; age 64.5 ± 16.2 years; BMI 26.6 ± 5.1 kg/m2) received both multi-phase single-energy CT (SECT) and DECT in sequential staging examinations with a third-generation dual-source scanner. Patients were allocated to one of three BMI clusters: non-obese: <25 kg/m2 (n = 110), pre-obese: 25-29.9 kg/m2 (n = 73), and obese: >30 kg/m2 (n = 70). Radiation dose and image quality were compared for each scan. DECT examinations were evaluated regarding liver coverage within the dual-energy field of view. RESULTS While arterial contrast phases in DECT were associated with a higher CTDIvol than in SECT (11.1 vs. 8.1 mGy; p < 0.001), replacement of true with virtual non-contrast imaging resulted in a considerably lower overall dose-length product (312.6 vs. 475.3 mGy·cm; p < 0.001). The proportion of DLP variance predictable from patient BMI was substantial in DECT (R2 = 0.738) and SECT (R2 = 0.620); however, DLP of SECT showed a stronger increase in obese patients (p < 0.001). Incomplete coverage of the liver within the dual-energy field of view was most common in the obese subgroup (17.1%) compared with non-obese (0%) and pre-obese patients (4.1%). CONCLUSION DECT facilitates a 30.8% dose reduction over SECT in abdominal oncologic staging examinations. Employing dual-source scanner architecture, the risk for incomplete liver coverage increases in obese patients.
Collapse
Affiliation(s)
- Henner Huflage
- Department of Diagnostic and Interventional Radiology, University Hospital Würzburg, 97080 Würzburg, Germany
| | - Andreas Steven Kunz
- Department of Diagnostic and Interventional Radiology, University Hospital Würzburg, 97080 Würzburg, Germany
| | - Robin Hendel
- Department of Diagnostic and Interventional Radiology, University Hospital Würzburg, 97080 Würzburg, Germany
| | - Johannes Kraft
- Department of Radiation Oncology, University Hospital Würzburg, 97080 Würzburg, Germany
| | - Stefan Weick
- Department of Radiation Oncology, University Hospital Würzburg, 97080 Würzburg, Germany
| | - Gary Razinskas
- Department of Radiation Oncology, University Hospital Würzburg, 97080 Würzburg, Germany
| | - Stephanie Tina Sauer
- Department of Diagnostic and Interventional Radiology, University Hospital Würzburg, 97080 Würzburg, Germany
| | - Lenhard Pennig
- Institute for Diagnostic and Interventional Radiology, Faculty of Medicine, University Hospital Cologne, 50931 Cologne, Germany
| | - Thorsten Alexander Bley
- Department of Diagnostic and Interventional Radiology, University Hospital Würzburg, 97080 Würzburg, Germany
| | - Jan-Peter Grunz
- Department of Diagnostic and Interventional Radiology, University Hospital Würzburg, 97080 Würzburg, Germany
| |
Collapse
|
2
|
Ma G, Han D, Dang S, Yu N, Yang Q, Yang C, Jin C, Dou Y. Replacing true unenhanced imaging in renal carcinoma with virtual unenhanced images in dual-energy spectral CT: a feasibility study. Clin Radiol 2020; 76:81.e21-81.e27. [PMID: 32993881 DOI: 10.1016/j.crad.2020.08.026] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/28/2019] [Accepted: 08/21/2020] [Indexed: 11/18/2022]
Abstract
AIM To investigate the clinical value of virtual unenhanced (VNC) spectral computed tomography (CT) images to replace the conventional true unenhanced spectral CT images (TNC) in diagnosing renal carcinoma. MATERIALS AND METHODS Fifty-six cases of renal carcinoma confirmed by histopathology underwent conventional plain CT and contrast-enhanced spectral CT at arterial phase (AP) and venous phase (VP). VNC images were generated on an AW4.6 workstation. The CT attenuation, image noise, contrast-to-noise ratio (CNR), and signal-noise-ratio (SNR) of the renal lesions and normal kidneys, long and short axis diameters of the lesion were measured from the three image sets and analysed using one-way analysis of variance (ANOVA). Two radiologists evaluated image quality subjectively using a five-point score, and lesion signature using a three-point score. Image quality scores were compared statistically and tested for consistency. RESULTS The two reviewers had good agreement for subjective evaluation (Kappa>0.70) and there was no difference in the quality of the scores among the three image groups. The lesion signature scores were all above the acceptable level. The CNR and SNR values in VNC were significantly higher than in TNC (p<0.05). VNC images had lower renal noise than in TNC (p<0.05). There was no difference in the long and short axis diameters of the lesion among the three image groups. VNC had higher CT attenuation values for the lesion and kidney than TNC (p<0.05), but the differences were <5 HU. CONCLUSION VNC images in spectral CT may be used to replace the conventional plain CT to reduce imaging duration and radiation dose in diagnosing renal carcinoma.
Collapse
Affiliation(s)
- G Ma
- Department of Radiology, Affiliated Hospital of Shaanxi University of Chinese Medicine, Xianyang, 712000, China
| | - D Han
- Department of Radiology, Affiliated Hospital of Shaanxi University of Chinese Medicine, Xianyang, 712000, China
| | - S Dang
- Department of Radiology, Affiliated Hospital of Shaanxi University of Chinese Medicine, Xianyang, 712000, China
| | - N Yu
- Department of Radiology, Affiliated Hospital of Shaanxi University of Chinese Medicine, Xianyang, 712000, China
| | - Q Yang
- Department of Radiology, Affiliated Hospital of Shaanxi University of Chinese Medicine, Xianyang, 712000, China
| | - C Yang
- Department of Radiology, Affiliated Hospital of Shaanxi University of Chinese Medicine, Xianyang, 712000, China
| | - C Jin
- Department of Radiology, The First Affiliated Hospital of Xi'an Jiaotong University, Yanta Western Road, Xi'an, Shannxi, 710061, China
| | - Y Dou
- Department of Radiology, Affiliated Hospital of Shaanxi University of Chinese Medicine, Xianyang, 712000, China.
| |
Collapse
|
3
|
Dual energy CT in clinical routine: how it works and how it adds value. Emerg Radiol 2020; 28:103-117. [PMID: 32483665 DOI: 10.1007/s10140-020-01785-2] [Citation(s) in RCA: 33] [Impact Index Per Article: 6.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/25/2020] [Accepted: 05/04/2020] [Indexed: 02/06/2023]
Abstract
Dual energy computed tomography (DECT), also known as spectral CT, refers to advanced CT technology that separately acquires high and low energy X-ray data to enable material characterization applications for substances that exhibit different energy-dependent x-ray absorption behavior. DECT supports a variety of post-processing applications that add value in routine clinical CT imaging, including material selective and virtual non-contrast images using two- and three-material decomposition algorithms, virtual monoenergetic imaging, and other material characterization techniques. Following a review of acquisition and post-processing techniques, we present a case-based approach to highlight the added value of DECT in common clinical scenarios. These scenarios include improved lesion detection, improved lesion characterization, improved ease of interpretation, improved prognostication, inherently more robust imaging protocols to account for unexpected pathology or suboptimal contrast opacification, length of stay reduction, reduced utilization by avoiding unnecessary follow-up examinations, and radiation dose reduction. A brief discussion of post-processing workflow approaches, challenges, and solutions is also included.
Collapse
|
4
|
Kraft M, Ibrahim M, Spector M, Forghani R, Srinivasan A. Comparison of virtual monochromatic series, iodine overlay maps, and single energy CT equivalent images in head and neck cancer conspicuity. Clin Imaging 2018; 48:26-31. [DOI: 10.1016/j.clinimag.2017.09.015] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/25/2017] [Revised: 09/21/2017] [Accepted: 09/26/2017] [Indexed: 10/18/2022]
|
5
|
Dual-Energy Computed Tomography Applications for the Evaluation of Cervical Lymphadenopathy. Neuroimaging Clin N Am 2017; 27:461-468. [PMID: 28711205 DOI: 10.1016/j.nic.2017.04.002] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/17/2022]
Abstract
There is recent interest in the use of dual-energy computed tomography (CT) in head and neck imaging, and the results are encouraging. This article reviews dual-energy CT applications as complementary tools to conventional CT scanning in the evaluation of cervical lymphadenopathy. The article cites the most relevant studies and highlights their results. Single-source and dual-source dual-energy applications including virtual noncontrast images, linear and nonlinear image blending, monochromatic images, iodine quantification, and spectral Hounsfield unit attenuation curve analysis are reviewed. Future directions and research suggestions are discussed in brief.
Collapse
|
6
|
Otrakji A, Digumarthy SR, Lo Gullo R, Flores EJ, Shepard JAO, Kalra MK. Dual-Energy CT: Spectrum of Thoracic Abnormalities. Radiographics 2016; 36:38-52. [PMID: 26761530 DOI: 10.1148/rg.2016150081] [Citation(s) in RCA: 72] [Impact Index Per Article: 8.0] [Reference Citation Analysis] [Abstract] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/22/2022]
Abstract
Recent studies have demonstrated that dual-energy computed tomography (CT) can provide useful information in several chest-related clinical indications. Compared with single-energy CT, dual-energy CT of the chest is feasible with the use of a radiation-dose-neutral scanning protocol. This article highlights the different types of images that can be generated by using dual-energy CT protocols such as virtual monochromatic, virtual unenhanced (ie, water), and pulmonary blood volume (ie, iodine) images. The physical basis of dual-energy CT and material decomposition are explained. The advantages of the use of virtual low-monochromatic images include reduced volume of intravenous contrast material and improved contrast resolution of images. The use of virtual high-monochromatic images can reduce beam hardening and contrast streak artifacts. The pulmonary blood volume images can help differentiate various parenchymal abnormalities, such as infarcts, atelectasis, and pneumonias, as well as airway abnormalities. The pulmonary blood volume images allow quantitative and qualitative assessment of iodine distribution. The estimation of iodine concentration (quantitative assessment) provides objective analysis of enhancement. The advantages of virtual unenhanced images include differentiation of calcifications, talc, and enhanced thoracic structures. Dual-energy CT has applications in oncologic imaging, including diagnosis of thoracic masses, treatment planning, and assessment of response to treatment. Understanding the concept of dual-energy CT and its clinical application in the chest are the goals of this article.
Collapse
Affiliation(s)
- Alexi Otrakji
- From the Division of Thoracic Imaging, Department of Radiology, Massachusetts General Hospital, Harvard Medical School, 55 Fruit St, Founders 213, Boston, MA 02114
| | - Subba R Digumarthy
- From the Division of Thoracic Imaging, Department of Radiology, Massachusetts General Hospital, Harvard Medical School, 55 Fruit St, Founders 213, Boston, MA 02114
| | - Roberto Lo Gullo
- From the Division of Thoracic Imaging, Department of Radiology, Massachusetts General Hospital, Harvard Medical School, 55 Fruit St, Founders 213, Boston, MA 02114
| | - Efren J Flores
- From the Division of Thoracic Imaging, Department of Radiology, Massachusetts General Hospital, Harvard Medical School, 55 Fruit St, Founders 213, Boston, MA 02114
| | - Jo-Anne O Shepard
- From the Division of Thoracic Imaging, Department of Radiology, Massachusetts General Hospital, Harvard Medical School, 55 Fruit St, Founders 213, Boston, MA 02114
| | - Mannudeep K Kalra
- From the Division of Thoracic Imaging, Department of Radiology, Massachusetts General Hospital, Harvard Medical School, 55 Fruit St, Founders 213, Boston, MA 02114
| |
Collapse
|