1
|
Liu Y, Zhao Z, Xu P, Li Y, Chang W, Ji M. Initial experience with the Carina™ platform in robotic-assisted hysterectomy for gynecological malignant disease. Surg Endosc 2025; 39:2346-2353. [PMID: 39966128 PMCID: PMC11933141 DOI: 10.1007/s00464-025-11588-6] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/12/2024] [Accepted: 01/26/2025] [Indexed: 02/20/2025]
Abstract
OBJECTIVE This retrospective study was performed to evaluate the efficiency and safety of a new modular robotic system, the Carina™ Platform (Ronovo Surgical, Shanghai, China), in gynecological surgery. METHODS All patients underwent robotic hysterectomies (RH) using the Carina performed by a single gynecologist experienced in laparoscopic and robotic surgery from November to December 2023. Patients were evaluated for estimated blood loss (EBL), intraoperative and postoperative complications, length of hospital stay, conversion rate, as well as console and docking times. RESULTS Two separate populations were involved: 10 cervical cancer patients (group 1) and six endometrial cancer patients (group 2). There were no conversions to laparotomies or laparoscopies. The mean docking time was 5.75 ± 2.38 min. The mean console time and mean operative time were 154.60 ± 26.01 min and 211.90 ± 53.65 min in group 1, respectively. The mean console time and mean operative time were 98.67 ± 26.71 min and 153.33 ± 22.77 min in group 2, respectively. The median estimated blood loss for group 1 and group 2 were 30 ml (20, 50) and 20 ml (7.5, 20), respectively. No intraoperative or postoperative complications related to the device were recorded. CONCLUSION Our experience allows us to state that the modular Carina Platform is safe and efficient in complex gynecologic surgery. CLINICAL TRIAL REGISTRATION researchregistry10353 https://www.researchregistry.com/browse-the-registry#home/registrationdetails/665c1a398a97c302739cce06/.
Collapse
Affiliation(s)
- Yafen Liu
- Department of Gynecology, The First Affiliated Hospital of Zhengzhou University, No. 1, Jianshe East Road, Erqi District, Zhengzhou, Henan, People's Republic of China
| | - Zhao Zhao
- Department of Gynecology, The First Affiliated Hospital of Zhengzhou University, No. 1, Jianshe East Road, Erqi District, Zhengzhou, Henan, People's Republic of China
| | - Penglin Xu
- Department of Gynecology, The First Affiliated Hospital of Zhengzhou University, No. 1, Jianshe East Road, Erqi District, Zhengzhou, Henan, People's Republic of China
| | - Yue Li
- Department of Gynecology, The First Affiliated Hospital of Zhengzhou University, No. 1, Jianshe East Road, Erqi District, Zhengzhou, Henan, People's Republic of China
| | - Weizhong Chang
- Department of Gynecology, The First Affiliated Hospital of Zhengzhou University, No. 1, Jianshe East Road, Erqi District, Zhengzhou, Henan, People's Republic of China
| | - Mei Ji
- Department of Gynecology, The First Affiliated Hospital of Zhengzhou University, No. 1, Jianshe East Road, Erqi District, Zhengzhou, Henan, People's Republic of China.
| |
Collapse
|
2
|
Sadlecki P, Walentowicz-Sadlecka M. Feasibility evaluation of the Versius surgical system: robot-assisted hysterectomy for benign and malignant gynaecological lesions. Arch Gynecol Obstet 2025; 311:355-365. [PMID: 39046468 PMCID: PMC11890229 DOI: 10.1007/s00404-024-07655-3] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/25/2024] [Accepted: 07/17/2024] [Indexed: 07/25/2024]
Abstract
INTRODUCTION The application of minimally invasive surgery allows for radical and precise removal of the gynaecological lesion while simultaneously reducing the side effects and complications associated with surgical treatment. This paper aims to share our direct experience with the implementation of the CMR Versius robotic platform in the treatment of benign and malignant gynaecological lesions. METHODS This study included patients who underwent hysterectomy in the Department of Obstetrics, Gynaecology, and Gynaecologic Oncology at the Regional Polyclinical Hospital in Grudziadz, Poland. A total of 50 patients were included in the study: 29 underwent laparoscopic surgery and 21 underwent robot-assisted surgery using the CMR Versius system. RESULTS It was found that in the case of non-radical hysterectomy, the duration of surgery differed significantly (96.5 vs. 134.6 min, p < 0.01) in the groups of patients undergoing laparoscopic and robotic surgery. There were also no statistically significant differences in loss of blood parameters, rate of complications and conversions to other type of surgery after the laparoscopic and robotic surgeries. Both groups did not differ significantly in terms of hospitalisation time after surgery. CONCLUSION Versius CMR surgical robot assistance provides safe and effective support for MIS procedures in gynaecology.
Collapse
Affiliation(s)
- Pawel Sadlecki
- Medical Department, University of Science and Technology, Bydgoszcz, Poland.
- Department of Obstetrics, Gynaecology and Gynaecologic Oncology, Regional Polyclinical Hospital, Grudziadz, Poland.
| | - Malgorzata Walentowicz-Sadlecka
- Medical Department, University of Science and Technology, Bydgoszcz, Poland
- Department of Obstetrics, Gynaecology and Gynaecologic Oncology, Regional Polyclinical Hospital, Grudziadz, Poland
| |
Collapse
|
3
|
Pisani Ceretti A, Mariani NM, Perego M, Giovenzana M, Salaj A, Formisano G, Gheza F, Gloria G, Bernardo R, Bianchi PP. Proposal of set-up standardization for general surgery procedures with the CMR Versius system, a new robotic platform: our initial experience. Langenbecks Arch Surg 2024; 409:107. [PMID: 38565787 DOI: 10.1007/s00423-024-03291-2] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/20/2023] [Accepted: 03/20/2024] [Indexed: 04/04/2024]
Abstract
BACKGROUND The article describes our initial experience using CMR Versius platform for several procedures in general surgery. METHODS Between September 2022 and April 2023, seventy patients underwent robotic surgery in a multi-robotic referral center (San Paolo University Hospital, Milan, Italy). Three surgeons with only laparoscopic experience performed 24 cholecystectomies, 13 inguinal hernia repairs, 9 ventral hernia repairs, 7 right hemicolectomies, 11 left hemicolectomies, 1 sigmoidectomy, 1 ileocecal resection, 1 ventral rectopexy, 1 Nissen fundoplication, 1 total splenectomy, and 1 exploration with multiple biopsies. RESULTS All surgeries were full-robotic, with only one conversion to laparoscopy. The short length of stay and low rate of severe morbidity are promising findings. Although operative time was lengthened, clinical outcomes were not affected. CONCLUSIONS Our experience demonstrates that the adoption of Versius system is safe and feasible in general surgery. The standardization of port placement and BSU set-up can certainly reduce the operative time.
Collapse
Affiliation(s)
- Andrea Pisani Ceretti
- Division of General and Robotic Surgery, Department of Health Sciences, ASST Santi Paolo E Carlo, University of Milan, Milan, Italy.
| | - Nicolò Maria Mariani
- Division of General and Robotic Surgery, Department of Health Sciences, ASST Santi Paolo E Carlo, University of Milan, Milan, Italy.
| | - Marta Perego
- Division of General and Robotic Surgery, Department of Health Sciences, ASST Santi Paolo E Carlo, University of Milan, Milan, Italy
| | - Marco Giovenzana
- Division of General and Robotic Surgery, Department of Health Sciences, ASST Santi Paolo E Carlo, University of Milan, Milan, Italy
| | - Adelona Salaj
- Division of General and Robotic Surgery, Department of Health Sciences, ASST Santi Paolo E Carlo, University of Milan, Milan, Italy
| | - Giampaolo Formisano
- Division of General and Robotic Surgery, Department of Health Sciences, ASST Santi Paolo E Carlo, University of Milan, Milan, Italy
| | - Federico Gheza
- Division of General Surgery, Department of Clinical and Experimental Sciences, University of Brescia and Civili Hospital, Brescia, Italy
| | - Gaia Gloria
- Division of Gynecology, Department of Health Sciences, ASST Santi Paolo E Carlo, University of Milan, Milan, Italy
| | - Rocco Bernardo
- Division of Urology, Department of Health Sciences, ASST Santi Paolo E Carlo, University of Milan, Milan, Italy
| | - Paolo Pietro Bianchi
- Division of General and Robotic Surgery, Department of Health Sciences, ASST Santi Paolo E Carlo, University of Milan, Milan, Italy
| |
Collapse
|
4
|
Adhikari K, Penmetsa GK, Krishnappa D, Taori R, Raghunath SK. Revolutionizing urology: the advancements and applications of robotic platforms. J Robot Surg 2024; 18:106. [PMID: 38436766 DOI: 10.1007/s11701-023-01758-w] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/01/2023] [Accepted: 10/14/2023] [Indexed: 03/05/2024]
Abstract
Robot-assisted surgery is developing as an acme of minimally invasive surgery, given its utmost dominance over laparoscopic surgery. The objective was to review the status of robotic surgery in urological practice with its advantages and disadvantages in current scenario. We conducted a literature search using MEDLINE and identified 72 articles which were relevant to urology. Single-port and various multiport robotic platforms like Da Vinci, Versius, Hugo RAS, Revo-I, Senhance, Mantra, Avatera, Hinotori, and MicroSurge are described with pros and cons. With a surge in different medical surgical robots purging into the market and a race to become the next standard of care in robotic surgery, it is only a matter of time when robotic surgery becomes financially comparable to laparoscopic surgeries.
Collapse
Affiliation(s)
- Kinju Adhikari
- Department of Uro Oncology and Robotic Surgery, HCG Cancer Center, Bengaluru, India
| | | | - Deepak Krishnappa
- Department of Uro Oncology and Robotic Surgery, HCG Cancer Center, Bengaluru, India
| | - Ravi Taori
- Department of Uro Oncology and Robotic Surgery, HCG Cancer Center, Bengaluru, India
| | - S K Raghunath
- Department of Uro Oncology and Robotic Surgery, HCG Cancer Center, Bengaluru, India.
| |
Collapse
|
5
|
Alkatout I, Becker T, Nuhn P, Pochhammer J, Peters G, Donald KM, Mettler L, Ackermann J. The first robotic-assisted hysterectomy below the bikini line with the Dexter robotic system™. Facts Views Vis Obgyn 2024; 16:87-91. [PMID: 38551479 PMCID: PMC11198885 DOI: 10.52054/fvvo.16.1.010] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 06/27/2024] Open
Abstract
Background Robotic-assisted hysterectomy (RAH) is a widely accepted minimally invasive approach for uterus removal. However, as RAH is typically performed in the umbilical region, it usually results in scars in cosmetically suboptimal locations. This is the first case of RAH with cervicosacropexy performed below the bikini line, using the new Dexter robotic system™. Objectives The aim of this article is to show the surgical steps of the first RAH with cervicosacropexy performed below the bikini line with the new Dexter robotic system™ (Distalmotion), and furthermore assess the feasibility of this approach using this robotic platform. Materials and Methods A 43-year-old woman with uterine adenomyosis and recurrent uterine prolapse underwent a robotic-assisted subtotal hysterectomy with cervicosacropexy, performed below the bikini line, using the Dexter robotic system™, at the Clinic of Gynecology and Obstetrics at Universitätsklinikum Schleswig-Holstein (UKHS) in Kiel, Germany. Main outcome measures Perioperative data, surgical approach specifics, objective, and subjective outcomes of this new approach. Results The procedure was performed without intra-operative complications; estimated blood loss was 10 ml. Operative time was 150 minutes, console time 120 minutes, total docking time 6 minutes. Dexter performed as expected; no device-related issues or robotic arm collisions occurred. The patient did not require pain medication and was released on the second postoperative day. Conclusion RAH performed below the bikini line using the Dexter robotic system™ is a feasible, safe, and adequate procedure. These initial results should be confirmed and further extensively refurbished with larger patient cohorts, and functional and psychological outcomes need further investigation.
Collapse
|
6
|
Brassetti A, Ragusa A, Tedesco F, Prata F, Cacciatore L, Iannuzzi A, Bove AM, Anceschi U, Proietti F, D’Annunzio S, Flammia RS, Chiacchio G, Ferriero M, Guaglianone S, Mastroianni R, Misuraca L, Tuderti G, Simone G. Robotic Surgery in Urology: History from PROBOT ® to HUGO TM. SENSORS (BASEL, SWITZERLAND) 2023; 23:7104. [PMID: 37631641 PMCID: PMC10458477 DOI: 10.3390/s23167104] [Citation(s) in RCA: 32] [Impact Index Per Article: 16.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/27/2023] [Revised: 08/06/2023] [Accepted: 08/10/2023] [Indexed: 08/27/2023]
Abstract
The advent of robotic surgical systems had a significant impact on every surgical area, especially urology, gynecology, and general and cardiac surgery. The aim of this article is to delineate robotic surgery, particularly focusing on its historical background, its evolution, its present status, and its future perspectives. A comprehensive literature review was conducted upon PubMed/MEDLINE, using the keywords "robotic surgical system", "robotic surgical device", "robotics AND urology". Additionally, the retrieved articles' reference lists were investigated. Analysis concentrated on urological surgical systems for laparoscopic surgery that have been given regulatory approval for use on humans. From the late 1980s, before daVinci® Era in 2000s, ancestor platform as Probot® and PUMA 560 were described to outline historical perspective. Thus, new robotic competitors of Intuitive Surgical such as Senhance®, Revo-I®, Versius®, Avatera®, Hinotori®, and HugoTM RAS were illustrated. Although daVinci® had high level competitiveness, and for many years represented the most plausible option for robotic procedures, several modern platforms are emerging in the surgical market. Growing competition through unique features of the new robotic technologies might extend applications fields, improve diffusion, and increase cost-effectiveness procedures. More experiences are needed to identify the role of these new advancements in surgical branches and in healthcare systems.
Collapse
Affiliation(s)
| | - Alberto Ragusa
- Department of Urology, IRCCS “Regina Elena” National Cancer Institute, 00128 Rome, Italy; (A.B.); (F.T.); (F.P.); (L.C.); (A.I.); (A.M.B.); (U.A.); (F.P.); (S.D.); (R.S.F.); (G.C.); (M.F.); (S.G.); (R.M.); (L.M.); (G.T.); (G.S.)
| | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | |
Collapse
|
7
|
Krebs TF, Kayser T, Lorenzen U, Grünewald M, Kayser M, Saltner A, Durmaz LO, Reese LJ, Brownlee E, Reischig K, Baastrup J, Meinzer A, Kalz A, Becker T, Bergholz R. Evaluation of the Versius Robotic System for Infant Surgery-A Study in Piglets of Less than 10 kg Body Weight. CHILDREN (BASEL, SWITZERLAND) 2023; 10:children10050831. [PMID: 37238379 DOI: 10.3390/children10050831] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/11/2023] [Revised: 04/19/2023] [Accepted: 04/21/2023] [Indexed: 05/28/2023]
Abstract
BACKGROUND We were able to demonstrate the feasibility of a new robotic system (Versius, CMR Surgical, Cambridge, UK) for procedures in small inanimate cavities. The aim of this consecutive study was to test the Versius® system for its feasibility, performance, and safety of robotic abdominal and thoracic surgery in piglets simulating infants with a body weight lower than 10 kg. METHODS A total of 24 procedures (from explorative laparoscopy to thoracoscopic esophageal repair) were performed in 4 piglets with a mean age of 12 days and a mean body weight of 6.4 (7-7.5) kg. Additional urological procedures were performed after euthanasia of the piglet. The Versius® robotic system was used with 5 mm wristed instruments and a 10 mm 3D 0° or 30° camera. The setup consisted of the master console and three to four separate arms. The performance of the procedure, the size, position, and the distance between the ports, the external and internal collisions, and complications of the procedures were recorded and analyzed. RESULTS We were able to perform all surgical procedures as planned. We encountered neither surgical nor robot-associated complications in the live model. Whereas all abdominal procedures could be performed successfully under general anesthesia, one piglet was euthanized early before the thoracic interventions, likely due to pulmonary inflammatory response. Technical limitations were based on the size of the camera (10 mm) being too large and the minimal insertion depth of the instruments for calibration of the fulcrum point. CONCLUSIONS Robotic surgery on newborns and infants appears technically feasible with the Versius® system. Software adjustments for fulcrum point calibration need to be implemented by the manufacturer as a result of our study. To further evaluate the Versius® system, prospective trials are needed, comparing it to open and laparoscopic surgery as well as to other robotic systems.
Collapse
Affiliation(s)
- Thomas Franz Krebs
- Department of General-, Visceral-, Thoracic-, Transplant- and Pediatric Surgery, UKSH University Hospital of Schleswig-Holstein Kiel Campus, Arnold-Heller-Strasse 3, 24105 Kiel, Germany
- Department of Pediatric Surgery, Ostschweizer Children's Hospital, Claudiusstrasse 6, 9006 St. Gallen, Switzerland
| | - Timo Kayser
- Department of General-, Visceral-, Thoracic-, Transplant- and Pediatric Surgery, UKSH University Hospital of Schleswig-Holstein Kiel Campus, Arnold-Heller-Strasse 3, 24105 Kiel, Germany
| | - Ulf Lorenzen
- Department of Anesthesia and Intensive Care Medicine, UKSH University Hospital of Schleswig-Holstein Kiel Campus, Arnold-Heller-Strasse 3, 24105 Kiel, Germany
| | - Matthias Grünewald
- Department of Anesthesia and Intensive Care Medicine, UKSH University Hospital of Schleswig-Holstein Kiel Campus, Arnold-Heller-Strasse 3, 24105 Kiel, Germany
- Department of Anesthesia and Intensive Care Medicine, Ev. Amalie Sieveking Hospital, Haselkamp 33, 22359 Hamburg, Germany
| | - Marit Kayser
- Department of General-, Visceral-, Thoracic-, Transplant- and Pediatric Surgery, UKSH University Hospital of Schleswig-Holstein Kiel Campus, Arnold-Heller-Strasse 3, 24105 Kiel, Germany
| | - Anna Saltner
- Department of General-, Visceral-, Thoracic-, Transplant- and Pediatric Surgery, UKSH University Hospital of Schleswig-Holstein Kiel Campus, Arnold-Heller-Strasse 3, 24105 Kiel, Germany
| | - Lidya-Olgu Durmaz
- Department of General-, Visceral-, Thoracic-, Transplant- and Pediatric Surgery, UKSH University Hospital of Schleswig-Holstein Kiel Campus, Arnold-Heller-Strasse 3, 24105 Kiel, Germany
| | - Lina Johanna Reese
- Department of General-, Visceral-, Thoracic-, Transplant- and Pediatric Surgery, UKSH University Hospital of Schleswig-Holstein Kiel Campus, Arnold-Heller-Strasse 3, 24105 Kiel, Germany
| | - Ewan Brownlee
- Department of Paediatric Surgery and Urology, Southampton Children's Hospital, University Hospital Southampton, Southampton SO16 6YD, UK
| | - Katja Reischig
- Department of General-, Visceral-, Thoracic-, Transplant- and Pediatric Surgery, UKSH University Hospital of Schleswig-Holstein Kiel Campus, Arnold-Heller-Strasse 3, 24105 Kiel, Germany
- Kurt-Semm-Center for Minimally Invasive and Robotic Surgery, UKSH University Hospital of Schleswig-Holstein Kiel Campus, Arnold-Heller-Strasse 3, 24105 Kiel, Germany
| | - Jonas Baastrup
- Department of General-, Visceral-, Thoracic-, Transplant- and Pediatric Surgery, UKSH University Hospital of Schleswig-Holstein Kiel Campus, Arnold-Heller-Strasse 3, 24105 Kiel, Germany
- Kurt-Semm-Center for Minimally Invasive and Robotic Surgery, UKSH University Hospital of Schleswig-Holstein Kiel Campus, Arnold-Heller-Strasse 3, 24105 Kiel, Germany
| | - Andreas Meinzer
- Department of General-, Visceral-, Thoracic-, Transplant- and Pediatric Surgery, UKSH University Hospital of Schleswig-Holstein Kiel Campus, Arnold-Heller-Strasse 3, 24105 Kiel, Germany
- Kurt-Semm-Center for Minimally Invasive and Robotic Surgery, UKSH University Hospital of Schleswig-Holstein Kiel Campus, Arnold-Heller-Strasse 3, 24105 Kiel, Germany
| | - Almut Kalz
- Kurt-Semm-Center for Minimally Invasive and Robotic Surgery, UKSH University Hospital of Schleswig-Holstein Kiel Campus, Arnold-Heller-Strasse 3, 24105 Kiel, Germany
| | - Thomas Becker
- Department of General-, Visceral-, Thoracic-, Transplant- and Pediatric Surgery, UKSH University Hospital of Schleswig-Holstein Kiel Campus, Arnold-Heller-Strasse 3, 24105 Kiel, Germany
- Kurt-Semm-Center for Minimally Invasive and Robotic Surgery, UKSH University Hospital of Schleswig-Holstein Kiel Campus, Arnold-Heller-Strasse 3, 24105 Kiel, Germany
| | - Robert Bergholz
- Department of General-, Visceral-, Thoracic-, Transplant- and Pediatric Surgery, UKSH University Hospital of Schleswig-Holstein Kiel Campus, Arnold-Heller-Strasse 3, 24105 Kiel, Germany
- Kurt-Semm-Center for Minimally Invasive and Robotic Surgery, UKSH University Hospital of Schleswig-Holstein Kiel Campus, Arnold-Heller-Strasse 3, 24105 Kiel, Germany
| |
Collapse
|
8
|
Li P, Zhan X, Lv C, Lin Z, Yang Y, Wang W, Wang S, Hao M, Zhu B, Bin X, Lang J, Liu P, Chen C. Comparison of the Oncological Outcomes Between Robot-Assisted and Abdominal Radical Hysterectomy for Cervical Cancer Based on the New FIGO 2018 Staging System: A Multicentre Retrospective Study. Front Oncol 2022; 12:879569. [PMID: 35847917 PMCID: PMC9280150 DOI: 10.3389/fonc.2022.879569] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/19/2022] [Accepted: 05/17/2022] [Indexed: 11/15/2022] Open
Abstract
Objective To compare the 3-year oncological outcomes of robot-assisted radical hysterectomy (RRH) and abdominal radical hysterectomy (ARH) for cervical cancer. Methods Based on the clinical diagnosis and treatment for cervical cancer in the China database, patients with FIGO 2018 stage IA with lymphovascular space invasion (LVSI)-IB2 cervical cancer disease who underwent RRH and ARH from 2004 to 2018 were included. Kaplan–Meier survival analysis was used to compare the 3-year overall survival (OS) and disease-free survival (DFS) rate between patients receiving RRH and those receiving ARH. The Cox proportional hazards model and propensity score matching were used to estimate the surgical approach-specific survival. Results A total of 1,137 patients with cervical cancer were enrolled in this study, including the RRH group (n = 468) and the ARH group (n = 669). The median follow-up time was 45 months (RRH group vs. ARH group: 24 vs. 60 months). Among the overall study population, there was no significant difference in 3-year OS and DFS between the RRH group and the ARH group (OS: 95.8% vs. 97.6% p = 0.244). The Cox proportional hazards analysis showed that RRH was not an independent risk factor for 3-year OS (HR: 1.394, 95% CI: 0.552–3.523, p = 0.482). However, RRH was an independent risk factor for 3-year DFS (HR: 1.985, 95% CI: 1.078–3.655 p = 0.028). After 1:1 propensity score matching, there was no significant difference in 3-year OS between the RRH group and the ARH group (96.6% vs. 98.0%, p = 0.470); however, the 3-year DFS of the RRH group was lower than that of the ARH group (91.0% vs. 96.1%, p = 0.025). The Cox proportional hazards analysis revealed that RRH was not an independent risk factor for 3-year OS (HR: 1.622, 95% CI: 0.449–5.860 p = 0.461), but RRH was an independent risk factor for 3-year DFS (HR: 2.498, 95% CI: 1.123–5.557 p = 0.025). Conclusion Among patients with stage I A1 (LVSI +)-I B2 cervical cancer based on the FIGO 2018 staging system, RRH has a lower 3-year DFS than ARH, suggesting that RRH may not be suitable for early cervical cancer patients.
Collapse
Affiliation(s)
- Pengfei Li
- Department of Obstetrics and Gynecology, Nanfang Hospital, Southern Medical University, Guangzhou, China
| | - Xuemei Zhan
- Department of Gynecology, Jiangmen Central Hospital, Jiangmen, China
| | - Chifei Lv
- Department of Obstetrics and Gynecology, Nanfang Hospital, Southern Medical University, Guangzhou, China
| | - Zhong Lin
- Department of Gynaecology Liuzhou Maternity and Child Healthcare Hospital, Liuzhou, China
| | - Ying Yang
- Department of Obstetrics and Gynecology, Xinqiao Hospital, Army Medical University, Chongqing, China
| | - Wuliang Wang
- Department of Obstetrics and Gynecology, The Second Affiliated Hospital of Zhengzhou University, Zhengzhou, China
| | - Shaoguang Wang
- Department of Gynecology, The Affiliated Yantai Yuhuangding Hospital of Qingdao University, Yantai, China
| | - Min Hao
- Department of Gynecology, the Second Hospital of Shanxi Medical University, Taiyuan, China
| | - Bin Zhu
- Department of Gynecology, The Affiliated Yiwu Women and Children Hospital of Hangzhou Medical College, Hangzhou, China
| | - Xiaonong Bin
- Department of Epidemiology, College of Public Health, Guangzhou Medical University, Guangzhou, China
| | - Jinghe Lang
- Department of Obstetrics and Gynecology, Peking Union Medical College Hospital, Peking Union Medical College, Beijing, China
| | - Ping Liu
- Department of Obstetrics and Gynecology, Nanfang Hospital, Southern Medical University, Guangzhou, China
- *Correspondence: Ping Liu, ; Chunlin Chen,
| | - Chunlin Chen
- Department of Obstetrics and Gynecology, Nanfang Hospital, Southern Medical University, Guangzhou, China
- *Correspondence: Ping Liu, ; Chunlin Chen,
| |
Collapse
|
9
|
Assessment of the Versius Robotic Surgical System in Minimal Access Surgery: A Systematic Review. J Clin Med 2022; 11:jcm11133754. [PMID: 35807035 PMCID: PMC9267445 DOI: 10.3390/jcm11133754] [Citation(s) in RCA: 19] [Impact Index Per Article: 6.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/14/2022] [Revised: 06/24/2022] [Accepted: 06/24/2022] [Indexed: 02/05/2023] Open
Abstract
Background: Despite the superiority of minimal access surgery (MAS) over open surgery, MAS is difficult to perform and has a demanding learning curve. Robot-assisted surgery is an advanced form of MAS. The Versius® surgical robot system was developed with the aim of overcoming some of the challenges associated with existing surgical robots. The present study was designed to investigate the feasibility, clinical safety, and effectiveness of the Versius system in MAS. Materials and Methods: A comprehensive search was carried out in the Medline, Web of Science Core Collection (Indexes = SCI-EXPANDED, SSCI, A & HCI Timespan), and Scopus databases for articles published until February 2022. The keywords used were Versius robot, visceral, colorectal, gynecology, and urologic surgeries. Articles on the use of the Versius robot in minimal access surgery (MAS) were included in the review. Results: Seventeen articles were reviewed for the study. The investigation comprised a total of 328 patients who had been operated on with this robot system, of which 48.3%, 14.2%, and 37.5% underwent colorectal, visceral, and gynecological procedures, respectively. Postoperative and major complications within 30 days varied from 7.4% to 39%. No major complications and no readmissions or reoperations were reported in visceral and gynecological surgeries. Readmission and reoperation rates in colorectal surgeries were 0–9%. Some procedures required conversion to conventional laparoscopic surgery (CLS) or open surgery, and all procedures were completed successfully. Based on the studies reviewed in the present report, we conclude that the Versius robot can be used safely and effectively in MAS. Conclusions: A review of the published literature revealed that the Versius system is safe and effective in minimal access surgery. However, the data should be viewed with caution until randomized controlled trials (RCTs) have been performed. Studies on the use of this robotic system in oncological surgery must include survival as one of the addressed outcomes.
Collapse
|
10
|
Hussein AA, Mohsin R, Qureshi H, Leghari R, Jing Z, Ramahi YO, Rizvi I, Guru KA, Rizvi A. Transition from da Vinci to Versius robotic surgical system: initial experience and outcomes of over 100 consecutive procedures. J Robot Surg 2022; 17:419-426. [PMID: 35752748 DOI: 10.1007/s11701-022-01422-9] [Citation(s) in RCA: 20] [Impact Index Per Article: 6.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/11/2022] [Accepted: 04/30/2022] [Indexed: 11/27/2022]
Abstract
We sought to describe the development of the robotic urology program at Sindh Institute of Urology and Transplantation (SIUT) and the feasibility of transitioning from the da Vinci to Versius robotic systems. The SIUT robotics program began in 2017 utilizing the da Vinci Si robotic system, transitioning to the Versius system in 2021. Retrospective review of our quality assurance database was performed. All procedures performed utilizing the two systems were identified, analyzed, and compared. Data were described with descriptive statistics. Matched procedures (by type of procedure) performed by the same surgeons utilizing the da Vinci and Versius were compared. All tests were double-sided with statistical significance set at p < 0.05.106 cases were performed by the Versius robotic surgical system in 2021. Median age was 42 years (IQR 26-56), and 69 (65%) were males. Procedures included both benign (83%) and malignant disorders (17%), several upper tract (75%), and pelvic/lower tract (25%). No major intraoperative complications were observed. Conversion to open occurred in six procedures. Malfunction of the robotic arms occurred in two procedures: the erroneous bedside units (BSU) were replaced. Eight patients developed postoperative high-grade complications. Matched analysis of various procedures (pyeloplasty, stone surgery, radical, partial, and simple nephrectomy) showed no significant difference in perioperative outcomes. To our knowledge, this is the first and largest series of urologic procedures performed by the Versius robotic surgical system.
Collapse
Affiliation(s)
- Ahmed A Hussein
- Department of Urology, A.T.L.A.S (Applied Technology Laboratory for Advanced Surgery) Program, Roswell Park Comprehensive Cancer Center, Elm & Carlton St Buffalo, Buffalo, NY, 14263, USA
| | - Rehan Mohsin
- Sindh Institute of Urology and Transplantation, Karachi, 74200, Pakistan
| | - Harris Qureshi
- Sindh Institute of Urology and Transplantation, Karachi, 74200, Pakistan
| | - Riaz Leghari
- Sindh Institute of Urology and Transplantation, Karachi, 74200, Pakistan
| | - Zhe Jing
- Department of Urology, A.T.L.A.S (Applied Technology Laboratory for Advanced Surgery) Program, Roswell Park Comprehensive Cancer Center, Elm & Carlton St Buffalo, Buffalo, NY, 14263, USA
| | - Yousuf O Ramahi
- Department of Urology, A.T.L.A.S (Applied Technology Laboratory for Advanced Surgery) Program, Roswell Park Comprehensive Cancer Center, Elm & Carlton St Buffalo, Buffalo, NY, 14263, USA
| | - Irfan Rizvi
- Mid Atlantic Permanente Medical Group PC, McLean, VA, 22102, USA
| | - Khurshid A Guru
- Department of Urology, A.T.L.A.S (Applied Technology Laboratory for Advanced Surgery) Program, Roswell Park Comprehensive Cancer Center, Elm & Carlton St Buffalo, Buffalo, NY, 14263, USA.
| | - Adib Rizvi
- Sindh Institute of Urology and Transplantation, Karachi, 74200, Pakistan
| |
Collapse
|
11
|
Reeves F, Challacombe B, Ribbits A, Ourselin S, Dasgupta P. IDEAL Stage 1/2a evaluation of urological procedures with the Versius robot. BJU Int 2022; 130:441-443. [PMID: 35717673 DOI: 10.1111/bju.15829] [Citation(s) in RCA: 12] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Affiliation(s)
| | | | | | | | - Prokar Dasgupta
- Guy's and St Thomas' NHS Foundation Trust, London, UK.,King's College London, King's Health Partners, London, UK
| |
Collapse
|
12
|
Dixon F, Khanna A, Vitish-Sharma P, Singh NS, Nakade K, Singh A, Qureshi A, O'Hara R, Keeler BD. Initiation and feasibility of a multi-specialty minimally invasive surgical programme using a novel robotic system: A case series. Int J Surg 2021; 96:106182. [PMID: 34848372 DOI: 10.1016/j.ijsu.2021.106182] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/02/2021] [Revised: 11/10/2021] [Accepted: 11/21/2021] [Indexed: 01/22/2023]
Abstract
INTRODUCTION There are a number of small case series examining new robotic surgical systems, but this is the first large case series assessing the feasibility of the Versius® system from CMR Surgical (1 Evolution Business Park, Cambridge, UK) in a multi-specialty setting. MATERIALS AND METHODS All patients undergoing Versius®-assisted surgery in a previously robot-naïve centre were consented for collection of data on demographics, pre-, intra-, and postoperative outcomes. Data collection was performed prospectively from the start of the robotic surgical programme. RESULTS 160 operations were performed over a 19-month period, including 68 colorectal, 60 gynaecology, and 32 general surgery cases. The conversion rate to open surgery was 4.4% for colorectal, and 0% for gynaecology and general surgery. Median length of stay was 6 days for colorectal, 1 day for gynaecology, and 0 days for general surgery. Other outcomes were comparable to existing literature for robotic assisted surgery. CONCLUSION The Versius® system is safe and feasible for use in a multi-specialty minimally invasive surgery programme, including colorectal, general surgical & gynaecological cases, and operative volume can be safely and easily scaled up in a district general hospital setting without prior robotic surgical experience.
Collapse
Affiliation(s)
- Frances Dixon
- Department of Colorectal Surgery, Milton Keynes University Hospital NHS Foundation Trust, MK6 5LD, UK Department of General Surgery, Milton Keynes University Hospital NHS Foundation Trust, MK6 5LD, UK Department of Obstetrics & Gynaecology, Milton Keynes University Hospital NHS Foundation Trust, MK6 5LD, UK University of Buckingham, Buckingham, MK18 1EG, UK
| | | | | | | | | | | | | | | | | |
Collapse
|
13
|
Koukourikis P, Rha KH. Robotic surgical systems in urology: What is currently available? Investig Clin Urol 2021; 62:14-22. [PMID: 33381927 PMCID: PMC7801159 DOI: 10.4111/icu.20200387] [Citation(s) in RCA: 43] [Impact Index Per Article: 10.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/26/2020] [Revised: 10/19/2020] [Accepted: 10/28/2020] [Indexed: 12/18/2022] Open
Abstract
Robotic assistance in laparoscopic surgery was introduced at the turn of this millennium, marking a milestone in the history of surgery. Urologists were early adopters of robotic technology and the indications of robot-assisted surgery in urology are expanding. Over the last 20 years, the da Vinci surgical system was the dominant system in the robotic surgical market. However, the recent expiration of Intuitive patents has allowed new systems to enter the market more freely. We performed a nonsystematic literature review using the PubMed/MEDLINE search engines. The aim of this review was to briefly summarize the currently available robotic surgical systems for laparoscopic urologic surgery. New surgical devices have already been launched in the robotic market and the da Vinci systems have some competition. The innovation of robotic technology is continuing, and new features such as an open-console design, haptic feedback, smaller instruments, and separately mounted robotic arms have been introduced. A new robotic era is rising, and new systems and technologies enhancing patient care are welcomed.
Collapse
Affiliation(s)
- Periklis Koukourikis
- Department of Urology, Urological Science Institute, Yonsei University College of Medicine, Seoul, Korea
| | - Koon Ho Rha
- Department of Urology, Urological Science Institute, Yonsei University College of Medicine, Seoul, Korea.
| |
Collapse
|
14
|
Advances and Trends in Pediatric Minimally Invasive Surgery. J Clin Med 2020; 9:jcm9123999. [PMID: 33321836 PMCID: PMC7764454 DOI: 10.3390/jcm9123999] [Citation(s) in RCA: 15] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/13/2020] [Revised: 11/28/2020] [Accepted: 12/03/2020] [Indexed: 12/11/2022] Open
Abstract
As many meta-analyses comparing pediatric minimally invasive to open surgery can be found in the literature, the aim of this review is to summarize the current state of minimally invasive pediatric surgery and specifically focus on the trends and developments which we expect in the upcoming years. Print and electronic databases were systematically searched for specific keywords, and cross-link searches with references found in the literature were added. Full-text articles were obtained, and eligibility criteria were applied independently. Pediatric minimally invasive surgery is a wide field, ranging from minimally invasive fetal surgery over microlaparoscopy in newborns to robotic surgery in adolescents. New techniques and devices, like natural orifice transluminal endoscopic surgery (NOTES), single-incision and endoscopic surgery, as well as the artificial uterus as a backup for surgery in preterm fetuses, all contribute to the development of less invasive procedures for children. In spite of all promising technical developments which will definitely change the way pediatric surgeons will perform minimally invasive procedures in the upcoming years, one must bear in mind that only hard data of prospective randomized controlled and double-blind trials can validate whether these techniques and devices really improve the surgical outcome of our patients.
Collapse
|
15
|
Gumbs AA, De Simone B, Chouillard E. Searching for a better definition of robotic surgery: is it really different from laparoscopy? MINI-INVASIVE SURGERY 2020. [DOI: 10.20517/2574-1225.2020.110] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 02/20/2025]
|