1
|
Satomi N, Miyasaka M, Enta Y, Munehisa Y, Toki Y, Nakashima M, Saigan M, Kobayashi Y, Teng Y, Maeda M, Kosuga M, Abe K, Taguri M, Hayatsu Y, Hata M, Tada N. Transcatheter Aortic Valve Replacement for Structural Valve Deterioration After Aortic Valve Neocuspidization. Catheter Cardiovasc Interv 2025. [PMID: 40370003 DOI: 10.1002/ccd.31583] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/16/2025] [Revised: 04/07/2025] [Accepted: 04/28/2025] [Indexed: 05/16/2025]
Abstract
BACKGROUND Evidence on structural valve deterioration (SVD) after aortic valve neocuspidization (AVNeo) remains limited. While transcatheter aortic valve replacement (TAVR) offers a less invasive option, its feasibility is unclear. This study aimed to characterize SVD patients post-AVNeo and to assess TAVR feasibility. METHODS This retrospective study included 11 patients who underwent TAVR for SVD after AVNeo in Sendai Kousei Hospital between June 2017 and August 2024. Four patients with aortic stenosis (AS) and seven with aortic regurgitation (AR) due to SVD were included. RESULTS AS-SVD group showed shorter time interval from AVNeo to TAVR (50.5 [28.3-98.3] vs. 107.0 [97.0-131.0] months, p = 0.04) and smaller aortic annulus area (316.5 [259.8-375.0] vs. 538.0 [440.0-582.0] mm2, p = 0.005) than AR-SVD group. In TAVR, technical success was achieved in 91% of cases. Although coronary obstruction is a concern due to the long leaflet, no case occurred. Misidentification of the basal ring plane caused by the slack cusp resulted in second valve implantation (one case) and new conduction disturbance (two cases) due to deep implantation, and aortic contained rupture (one case) for oversized valve selection. CONCLUSIONS Rapid AS-SVD progression and AR-SVD occurring later than previously reported were observed, highlighting the need for further studies on AVNeo durability. TAVR after AVNeo was feasible. Special precautions for coronary obstruction may be unnecessary. Careful hinge point placement at the boundary between pericardial cusps and the annulus was a key to CT-based basal ring determination in patients after AVNeo.
Collapse
Affiliation(s)
- Natsuko Satomi
- Department of Cardiology, Sendai Kousei Hospital, Miyagi, Japan
| | - Masaki Miyasaka
- Department of Cardiology, Sendai Kousei Hospital, Miyagi, Japan
- Department of Laboratory Medicine, The Jikei University School of Medicine, Tokyo, Japan
| | - Yusuke Enta
- Department of Cardiology, Sendai Kousei Hospital, Miyagi, Japan
| | | | - Yusuke Toki
- Department of Cardiology, Sendai Kousei Hospital, Miyagi, Japan
| | | | - Makoto Saigan
- Department of Cardiology, Sendai Kousei Hospital, Miyagi, Japan
| | - Yuta Kobayashi
- Department of Cardiology, Sendai Kousei Hospital, Miyagi, Japan
| | - Yun Teng
- Department of Cardiology, Sendai Kousei Hospital, Miyagi, Japan
| | - Manabu Maeda
- Department of Cardiology, Sendai Kousei Hospital, Miyagi, Japan
| | - Momo Kosuga
- Department of Cardiology, Sendai Kousei Hospital, Miyagi, Japan
| | - Kazuo Abe
- Department of Cardiovascular Surgery, Yamagata Prefectural Central Hospital, Yamagata, Japan
| | - Masataka Taguri
- Department of Health Data Science, Tokyo Medical University, Tokyo, Japan
| | - Yukihiro Hayatsu
- Department of Cardiovascular Surgery, Sendai Kousei Hospital, Miyagi, Japan
| | - Masaki Hata
- Department of Cardiovascular Surgery, Sendai Kousei Hospital, Miyagi, Japan
| | - Norio Tada
- Department of Cardiology, Sendai Kousei Hospital, Miyagi, Japan
| |
Collapse
|
2
|
Cabrucci F, Baudo M, Yamashita Y, Dokollari A, Sicouri S, Ramlawi B. Short and Long-Term Outcomes of Transcatheter Aortic Valve Implantation in the Small Aortic Annulus: A Systematic Literature Review. J Pers Med 2024; 14:937. [PMID: 39338191 PMCID: PMC11433187 DOI: 10.3390/jpm14090937] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/11/2024] [Revised: 08/28/2024] [Accepted: 08/31/2024] [Indexed: 09/30/2024] Open
Abstract
Transcatheter aortic valve implantation has revolutionized the treatment of aortic stenosis. The small aortic annulus is one of the most challenging aspects of aortic stenosis treatment and since the beginning, TAVI has shown promising results in this subgroup of patients. This systematic literature review aims to investigate the short and long-term outcomes of TAVI in the small aortic annulus. The literature was meticulously screened for this topic until April 2024 using the PRISMA guidelines. Technical aspects, characteristics of this subgroup of patients, hemodynamic performances, and outcomes are discussed. The importance of device selection has shown up, with insight into the differences between self-expandable and the balloon-expandable valves. Two special populations were also taken into account: outcomes of TAVI in the small aortic annulus with bicuspid aortic valve and extra-small aortic annulus. The last 10 years have been paramount in technological advancements, bringing TAVI to broader use in this population. While several important trials underscored the usefulness of TAVI in the small aortic annulus population, the clinical practice still lacks consensus on the ideal device, and the outcomes are debated. The pivotal role of TAVI in this context needs to be addressed with a patient-tailored approach to optimize patient care.
Collapse
Affiliation(s)
- Francesco Cabrucci
- Department of Cardiac Surgery Research, Lankenau Institute for Medical Research, Main Line Health, Wynnewood, PA 19096, USA
| | - Massimo Baudo
- Department of Cardiac Surgery Research, Lankenau Institute for Medical Research, Main Line Health, Wynnewood, PA 19096, USA
| | - Yoshiyuki Yamashita
- Department of Cardiac Surgery Research, Lankenau Institute for Medical Research, Main Line Health, Wynnewood, PA 19096, USA
- Department of Cardiac Surgery, Lankenau Heart Institute, Main Line Health, Wynnewood, PA 19096, USA
| | - Aleksander Dokollari
- Department of Cardiac Surgery Research, Lankenau Institute for Medical Research, Main Line Health, Wynnewood, PA 19096, USA
- Department of Cardiac Surgery, St. Boniface Hospital, University of Manitoba, Winnipeg, MB R2H 2A6, Canada
| | - Serge Sicouri
- Department of Cardiac Surgery Research, Lankenau Institute for Medical Research, Main Line Health, Wynnewood, PA 19096, USA
| | - Basel Ramlawi
- Department of Cardiac Surgery Research, Lankenau Institute for Medical Research, Main Line Health, Wynnewood, PA 19096, USA
- Department of Cardiac Surgery, Lankenau Heart Institute, Main Line Health, Wynnewood, PA 19096, USA
| |
Collapse
|
3
|
Fialka NM, EL-Andari R, Wang S, Dokollari A, Kent WDT, Fatehi Hassanabad A. The Perceval Sutureless Bioprosthetic Aortic Valve: Evolution of Surgical Valve Technology. INNOVATIONS-TECHNOLOGY AND TECHNIQUES IN CARDIOTHORACIC AND VASCULAR SURGERY 2024; 19:125-135. [PMID: 38465600 PMCID: PMC11055413 DOI: 10.1177/15569845241231989] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 03/12/2024]
Abstract
OBJECTIVE The surgical treatment of aortic stenosis continues to evolve, and sutureless aortic valve replacement (SUAVR) is an emerging technology. With the Perceval S (Corcym, London, UK) as the only true sutureless valve on the market, the objective of this review is to analyze the current literature on Perceval S. Focusing on valve design and deployment as well as applications of the technology for challenging pathology, clinical outcomes are assessed, including a comparison with transcatheter AVR (TAVR). METHODS PubMed and MEDLINE were searched by 3 authors for studies analyzing SUAVR from inception to May 19, 2023. RESULTS SUAVR facilitates minimally invasive surgery and offers an alternative strategy for patients with small aortic annuli. It also has a time-saving advantage for patients who require complex operations. SUAVR results in excellent long-term morbidity, mortality, durability, and hemodynamic function. In comparison with conventional surgical AVR (SAVR), SUAVR does have a greater risk of postoperative pacemaker implantation; however, increasing user experience and refinements in implantation technique have contributed to reductions in this outcome. SUAVR results in morbidity and mortality that is similar to rapid-deployment AVR. Midterm outcomes are superior to TAVR; however, further robust investigation into all of these comparisons is ultimately necessary. CONCLUSIONS SUAVR bridges the gap in technology between SAVR and TAVR. The application of this exciting technology will undoubtedly grow in the coming years, during which additional investigation is paramount to optimize preoperative planning, valve deployment, and reintervention strategies.
Collapse
Affiliation(s)
- Nicholas M. Fialka
- Division of Cardiac Surgery, Department of Surgery, University of Alberta, Edmonton, AB, Canada
| | - Ryaan EL-Andari
- Division of Cardiac Surgery, Department of Surgery, University of Alberta, Edmonton, AB, Canada
| | - Shaohua Wang
- Division of Cardiac Surgery, Department of Surgery, University of Alberta, Edmonton, AB, Canada
| | - Aleksander Dokollari
- Section of Cardiac Surgery, St. Boniface Hospital, University of Manitoba, Winnipeg, MB, Canada
| | - William D. T. Kent
- Section of Cardiac Surgery, Division of Cardiac Sciences, Libin Cardiovascular Institute, University of Calgary, AB, Canada
| | - Ali Fatehi Hassanabad
- Section of Cardiac Surgery, Division of Cardiac Sciences, Libin Cardiovascular Institute, University of Calgary, AB, Canada
| |
Collapse
|
4
|
Matkovic M, Aleksic N, Bilbija I, Antic A, Lazovic JM, Cubrilo M, Milojevic A, Zivkovic I, Putnik S. Clinical Impact of Patient-Prosthesis Mismatch After Aortic Valve Replacement With a Mechanical or Biological Prosthesis. Tex Heart Inst J 2023; 50:e228048. [PMID: 37867308 PMCID: PMC10658167 DOI: 10.14503/thij-22-8048] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/24/2023]
Abstract
BACKGROUND Patient-prosthesis mismatch (PPM) may impair functional capacity and survival after aortic valve replacement. This study aimed to investigate the impact of PPM on long-term survival and quality of life after mechanical and biological aortic valve replacement. METHODS This study included 595 consecutive patients who had undergone isolated aortic valve replacement. Patients were divided into 2 groups according to prosthesis type. The baseline and operative characteristics, survival rates, complications, and quality of life of the groups with and without PPM were compared for up to 6 years. The PPM calculation was performed using the effective orifice area value provided by the manufacturer divided by the patient's body surface area. RESULTS The moderate to severe PPM rates were 69.8% and 3.7% after biological and mechanical prosthesis implantation, respectively. Mean survival for patients in the biological group who had PPM was statistically significantly shorter (50.2 months [95% CI, 45.2-55.3]) than for patients in the biological group without PPM (60.1 months [95% CI, 55.7-64.4]; P = .04). In the mechanical prosthesis group, there was no difference in mean survival between the subgroup with PPM (66.6 months [95% CI, 58.3-74.9]) and the subgroup without PPM (64.9 months [95% CI, 62.6-67.2]; P = .50). A quality-of-life questionnaire's scores did not differ between the groups. CONCLUSION Mismatch is common after biological valve implantation and statistically significantly affects long-term survival and quality of life. If the risk of PPM after implantation of a biological prosthesis is suspected, adopting strategies to avoid PPM at the time of surgery is warranted.
Collapse
Affiliation(s)
- Milos Matkovic
- Department for Cardiac Surgery, Clinical Centre of Serbia, Belgrade, Serbia
- Faculty of Medicine, University of Belgrade, Belgrade, Serbia
| | - Nemanja Aleksic
- Department for Cardiac Surgery, Clinical Centre of Serbia, Belgrade, Serbia
- Faculty of Medicine, University of Belgrade, Belgrade, Serbia
| | - Ilija Bilbija
- Department for Cardiac Surgery, Clinical Centre of Serbia, Belgrade, Serbia
- Faculty of Medicine, University of Belgrade, Belgrade, Serbia
| | - Ana Antic
- Department for Cardiac Surgery, Clinical Centre of Serbia, Belgrade, Serbia
| | - Jelena Milin Lazovic
- Department for Biostatistics, Faculty of Medicine, University of Belgrade, Belgrade, Serbia
| | - Marko Cubrilo
- Department for Cardiac Surgery, Clinical Centre of Serbia, Belgrade, Serbia
| | | | - Igor Zivkovic
- Faculty of Medicine, University of Belgrade, Belgrade, Serbia
- Department for Cardiac Surgery, Dedinje Cardiovascular Institute, Belgrade, Serbia
| | - Svetozar Putnik
- Department for Cardiac Surgery, Clinical Centre of Serbia, Belgrade, Serbia
- Faculty of Medicine, University of Belgrade, Belgrade, Serbia
| |
Collapse
|
5
|
Sazzad F, Ramanathan K, Moideen IS, Gohary AE, Stevens JC, Kofidis T. A Systematic Review of Individualized Heart Surgery with a Personalized Prosthesis. J Pers Med 2023; 13:1483. [PMID: 37888094 PMCID: PMC10608049 DOI: 10.3390/jpm13101483] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/16/2023] [Revised: 10/05/2023] [Accepted: 10/10/2023] [Indexed: 10/28/2023] Open
Abstract
Personalized surgery is not just a new trend but rather a patient-specific approach to therapy that makes it possible to adopt a targeted approach for a specific patient and closely mirrors the approach of personalized medicine. However, the application of tailored surgery in the context of cardiovascular replacement surgery has not been systematically reviewed. The ability to customize a device is highly dependent on the collection of radiological image data for precise prosthesis modeling. These facts are essential to "tailor-made" device design for precise prosthesis implantation. According to this study, computed tomography (CT) was the most prominent imaging modality; however, transesophageal echocardiography and echocardiography were also found to be helpful. Additionally, a dynamic finite element simulation was also found to be an attractive alternative to the finite element analysis for an in-silico experiment. Nonetheless, there is a paucity of relevant publications and only sporadic evidence. More clinical studies have been warranted, notwithstanding that the derived data and results from this insight into the use of therapeutic interventions may be evidence of multiple directives in clinical practices and beyond. This study may help the integration of personalized devices for better comprehension of predicted clinical outcomes, thus leading towards enhanced performance gains.
Collapse
Affiliation(s)
- Faizus Sazzad
- Department of Surgery, Yong Loo Lin School of Medicine, National University of Singapore, Singapore 117599, Singapore
| | - Kollengode Ramanathan
- Department of Surgery, Yong Loo Lin School of Medicine, National University of Singapore, Singapore 117599, Singapore
- Department of Cardiac, Thoracic and Vascular Surgery, National University Heart Centre, Singapore 119228, Singapore
| | - Irwan Shah Moideen
- Department of Surgery, Yong Loo Lin School of Medicine, National University of Singapore, Singapore 117599, Singapore
| | - Abdulrahman El Gohary
- Department of Surgery, Yong Loo Lin School of Medicine, National University of Singapore, Singapore 117599, Singapore
| | - John Carey Stevens
- Department of Surgery, Yong Loo Lin School of Medicine, National University of Singapore, Singapore 117599, Singapore
| | - Theo Kofidis
- Department of Surgery, Yong Loo Lin School of Medicine, National University of Singapore, Singapore 117599, Singapore
- Department of Cardiac, Thoracic and Vascular Surgery, National University Heart Centre, Singapore 119228, Singapore
| |
Collapse
|
6
|
Amirghofran AA, Salimi M, Kamran H, Bazrafshan H, Navaei MR, Shokrollahi A, Nirooei E, Edraki M, Amoozgar H, Ajami G, Arabi H. Long-term outcomes of the classic Konno-Rastan procedure in paediatric and adult patients: impact of aortic annulus size on patient outcomes. INTERDISCIPLINARY CARDIOVASCULAR AND THORACIC SURGERY 2023; 37:ivad151. [PMID: 37665750 DOI: 10.1093/icvts/ivad151] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/10/2022] [Revised: 07/14/2023] [Accepted: 09/02/2023] [Indexed: 09/06/2023]
Abstract
OBJECTIVES The classic Konno-Rastan procedure may yield different outcomes regarding aortic annulus diameters ≤15 mm and larger. Focusing on the effect of the diameter of the aortic annulus, we described the long-term outcomes of our patients. METHODS The outcomes of paediatric and adult patients who underwent surgery from 2000 to 2021 were studied retrospectively. The patient population was divided into 2 groups with aortic annulus diameters ≤15 mm and >15, and the outcomes were compared between the 2 groups. RESULTS A total of 48 patients, with a mean age of 12.24 ± 9.42 years (2-53 years) and a median follow-up duration of 8 years (7 months to 20 years) with an IQR of 5.5, were enrolled. The mean peak instantaneous pressure gradient was 78.97 ± 25.29 mmHg, which decreased to 21.43 mmHg (P-value = 0.012). The maximum left ventricular outflow tract gradient at the last follow-up was 28.21 mmHg, with the exception of 1 case with a gradient of 68.45 mmHg. The mean diameter of the aortic annulus was 15.34 ± 3.87 mm (8-23 mm), and the mean prosthetic valve size was 20.31 mm, which was 5 mm (33%) larger than the native annulus diameter. The overall mortality rate was 6.3%, with 1 death in the hospital and 2 in the first year after the surgery. The major complication rate, including mortality, heart block and reintervention, was higher in patients with ≤15 mm annulus (P-value = 0.028.) However, there was no difference between the 2 groups in follow-up. Four (8%) late cardiac reoperations were performed, none of which were related to our surgeries. CONCLUSIONS Kono-Rastan surgery for patients with aortic valve diameter of ≤15 mm can be performed with acceptable long-term outcomes.
Collapse
Affiliation(s)
| | - Maryam Salimi
- Student Research Committee, Shiraz University of Medical Sciences, Shiraz, Iran
| | - Hooman Kamran
- Student Research Committee, Shiraz University of Medical Sciences, Shiraz, Iran
| | - Hamed Bazrafshan
- Cardiac Surgery Department, Shiraz University of Medical Sciences, Shiraz, Iran
| | | | - Ali Shokrollahi
- Cardiac Surgery Department, Shiraz University of Medical Sciences, Shiraz, Iran
| | - Elahe Nirooei
- Cardiac Surgery Department, Shiraz University of Medical Sciences, Shiraz, Iran
| | - Mohammadreza Edraki
- Pediatric Cardiology Department, Shiraz University of Medical Sciences, Shiraz, Iran
| | - Hamid Amoozgar
- Pediatric Cardiology Department, Shiraz University of Medical Sciences, Shiraz, Iran
| | - Gholamhossein Ajami
- Pediatric Cardiology Department, Shiraz University of Medical Sciences, Shiraz, Iran
| | - Hamid Arabi
- Cardiac Surgery Department, Shiraz University of Medical Sciences, Shiraz, Iran
| |
Collapse
|
7
|
Maeda K, Shimamura K, Yoshioka D, Inoue K, Yamada S, Yamashita K, Kawamura A, Hiraoka A, Yoshitaka H, Kitabayashi K, Kondoh H, Yoshikawa Y, Shirakawa Y, Miyagawa S. Midterm outcomes after surgical aortic valve replacement with the INSPIRIS RESILIA from a multicenter AVR registry. J Cardiol 2023; 82:261-267. [PMID: 37276990 DOI: 10.1016/j.jjcc.2023.05.012] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/19/2023] [Revised: 05/19/2023] [Accepted: 05/24/2023] [Indexed: 06/07/2023]
Abstract
BACKGROUND There have been few reports on the mid- to long-term safety and efficacy validation of the INSPIRIS RESILIA aortic bioprosthesis (Edwards Lifesciences LLC, Irvine, CA, USA) in Japan. Herein, we report the mid-term results of surgical aortic valve replacement (AVR) for aortic stenosis using INSPIRIS and evaluate the hemodynamics compared to the CEP Magna series from the multicenter AVR registry (the ACTIVIST registry). METHODS Of the 1967 patients who underwent surgical or transcatheter AVR from the ACTIVIST registry, 66 patients who underwent isolated surgical AVR with INSPIRIS by December 2020 were included in this study, and the early and mid-term results were evaluated. Hemodynamics were evaluated by comparing 272 patients undergoing isolated surgical AVR with the Magna group using propensity score matching. RESULTS The mean age was 74.0 ± 7.8 years, and 48.5 % were women. In-hospital mortality was 1.5 %, and the survival rates at 1- and 2-years were 95.2 % and 95.2 %, respectively. After propensity score matching, echocardiographic findings at discharge demonstrated that peak velocity and mean pressure gradient in the INSPIRIS group were comparable, while the effective orifice area in the INSPIRIS group was significantly larger than those in the Magna group (p = 0.048). A patient-prosthesis mismatch at discharge was significantly lower in the INSPIRIS group (11.8 %) than in the Magna group (36.4 %) (p = 0.004). CONCLUSIONS Surgical AVR with INSPIRIS was performed safely and the mid-term results were satisfactory. The hemodynamics of INSPIRIS were comparable to those of Magna.
Collapse
Affiliation(s)
- Koichi Maeda
- Department of Cardiovascular Surgery, Osaka University Graduate School of Medicine, Suita City, Osaka, Japan.
| | - Kazuo Shimamura
- Department of Cardiovascular Surgery, Osaka University Graduate School of Medicine, Suita City, Osaka, Japan
| | - Daisuke Yoshioka
- Department of Cardiovascular Surgery, Osaka University Graduate School of Medicine, Suita City, Osaka, Japan
| | - Koichi Inoue
- Department of Cardiovascular Surgery, Osaka University Graduate School of Medicine, Suita City, Osaka, Japan
| | - Shohei Yamada
- Department of Cardiovascular Surgery, Osaka University Graduate School of Medicine, Suita City, Osaka, Japan
| | - Kizuku Yamashita
- Department of Cardiovascular Surgery, Osaka University Graduate School of Medicine, Suita City, Osaka, Japan
| | - Ai Kawamura
- Department of Cardiovascular Surgery, Osaka University Graduate School of Medicine, Suita City, Osaka, Japan
| | - Arudo Hiraoka
- Department of Cardiovascular Surgery, The Sakakibara Heart Institute of Okayama, Okayama City, Okayama, Japan
| | - Hidenori Yoshitaka
- Department of Cardiovascular Surgery, The Sakakibara Heart Institute of Okayama, Okayama City, Okayama, Japan
| | - Katsukiyo Kitabayashi
- Department of Cardiovascular Surgery, Japan Organization of Occupational Health and Safety Kansai Rosai Hospital, Amagasaki City, Hyogo, Japan
| | - Haruhiko Kondoh
- Department of Cardiovascular Surgery, Japan Organization of Occupational Health and Safety Osaka Rosai Hospital, Sakai City, Osaka, Japan
| | - Yasushi Yoshikawa
- Division of Cardiovascular Surgery, Department of Surgery, Tottori University School of Medicine, Yonago City, Tottori, Japan
| | - Yukitoshi Shirakawa
- Department of Cardiovascular Surgery, Osaka General Medical Center, Osaka City, Osaka, Japan
| | - Shigeru Miyagawa
- Department of Cardiovascular Surgery, Osaka University Graduate School of Medicine, Suita City, Osaka, Japan
| |
Collapse
|
8
|
Chen JS, Huang JH, Chiu KM, Chiang CY. Extent of Left Ventricular Mass Regression and Impact of Global Left Ventricular Afterload on Cardiac Events and Mortality after Aortic Valve Replacement. J Clin Med 2022; 11:jcm11247482. [PMID: 36556098 PMCID: PMC9783780 DOI: 10.3390/jcm11247482] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/14/2022] [Revised: 12/09/2022] [Accepted: 12/12/2022] [Indexed: 12/23/2022] Open
Abstract
Patient-prosthesis mismatch (PPM) causes a high transvalvular pressure gradient and residual left ventricular (LV) hypertrophy, consequently influencing long-term results. This study aimed to find the relationships between hemodynamic parameters and LV mass regression and determine the risk predictors of major adverse cardiovascular and cerebral events (MACCE) after aortic valve replacement (AVR) for aortic stenosis. Methods and Results: Preoperative and postoperative Doppler echocardiography data were evaluated for 120 patients after AVR. The patients' mean age was 67.7 years; 55% of the patients were male. Forty-four (37%) patients suffered from MACCE during a mean follow-up period of 3.6 ± 2 years. The following hemodynamic parameters at follow-up were associated with lower relative indexed LV mass (LVMI) regression: lower postoperative indexed effective orifice area, greater mean transvalvular pressure gradient (MPG), greater stroke work loss (SWL), and concentric or eccentric LV remodeling mode. The following hemodynamic parameters at follow-up were associated with a higher risk of MACCE: higher valvuloarterial impedance (ZVA), greater SWL, greater MPG, greater relative wall thickness, greater LVMI, and hypertrophic LV remodeling mode. Lower relative LVMI regression was associated with a higher risk of MACCE (hazard ratio, 1.01: 95% confidence interval, 1.003-1.03). The corresponding cutoff of relative LVMI regression was -14%. Conclusions: Changes in hemodynamic parameters were independently associated with relative LVMI regression. Impaired reverse remodeling and persistent residual LV hypertrophy were independent risk predictors of MACCE. An LVMI regression lower than 14% indicated higher MACCE. A postoperative ZVA greater than 3.5 mmHg/mL/m2 was an independent risk predictor of cardiac events and mortality after AVR. Preventive strategies should be used at the time of the operation to avoid PPM.
Collapse
Affiliation(s)
- Jer-Shen Chen
- Department of Cardiovascular Surgery, Cardiovascular Center, Far Eastern Memorial Hospital, New Taipei City 220216, Taiwan
- Department of Healthcare Administration, Asian Eastern University of Science and Technology, New Taipei City 220303, Taiwan
| | - Jih-Hsin Huang
- Department of Cardiovascular Surgery, Cardiovascular Center, Far Eastern Memorial Hospital, New Taipei City 220216, Taiwan
- Department of Applied Cosmetology, LeeMing Institute of Technology, New Taipei City 243083, Taiwan
| | - Kuan-Ming Chiu
- Department of Cardiovascular Surgery, Cardiovascular Center, Far Eastern Memorial Hospital, New Taipei City 220216, Taiwan
- Department of Electrical Engineering, Yuan Ze University, Taoyuan 320315, Taiwan
| | - Chih-Yao Chiang
- Department of Cardiovascular Surgery, Cardiovascular Center, Far Eastern Memorial Hospital, New Taipei City 220216, Taiwan
- Division of Cardiovascular Surgery, Department of Surgery, School of Medicine, National Defense Medical Center, Taipei 114201, Taiwan
- Correspondence: ; Tel.: +886-2-7728-1618; Fax: +886-2-7738-6057
| |
Collapse
|
9
|
Joury A, Duran A, Stewart M, Gilliland YE, Spindel SM, Qamruddin S. Prosthesis-patient mismatch following aortic and mitral valves replacement – A comprehensive review. Prog Cardiovasc Dis 2022; 72:84-92. [PMID: 35235847 DOI: 10.1016/j.pcad.2022.02.004] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/22/2022] [Accepted: 02/22/2022] [Indexed: 11/29/2022]
Affiliation(s)
- Abdulaziz Joury
- Department of Cardiology, Ochsner Medical Center, New Orleans, LA, United States of America; King Salman Heart Center, King Fahad Medical City, Riyadh, Saudi Arabia.
| | - Antonio Duran
- Department of Cardiology, Ochsner Medical Center, New Orleans, LA, United States of America; Ochsner Clinical School, New Orleans, LA, United States of America.
| | - Merrill Stewart
- Department of Cardiology, Ochsner Medical Center, New Orleans, LA, United States of America; Ochsner Clinical School, New Orleans, LA, United States of America.
| | - Yvonne E Gilliland
- Department of Cardiology, Ochsner Medical Center, New Orleans, LA, United States of America; Ochsner Clinical School, New Orleans, LA, United States of America
| | - Stephen M Spindel
- Ochsner Clinical School, New Orleans, LA, United States of America; Division of Cardiothoracic Surgery, Ochsner Medical Center, New Orleans, LA, United States of America.
| | - Salima Qamruddin
- Department of Cardiology, Ochsner Medical Center, New Orleans, LA, United States of America; Ochsner Clinical School, New Orleans, LA, United States of America.
| |
Collapse
|
10
|
Vallabhaneni S, Matka M, Modi V, Carey M, Sarnoski C, Durkin R, Olenchock S, Razzaghi M, Shirani J. Prevalence and Significance of Patient Prosthesis Mismatch Following Edwards SAPIEN XT and SAPIEN 3 Transcatheter Aortic Valve Replacement. Cureus 2021; 13:e18044. [PMID: 34692277 PMCID: PMC8523339 DOI: 10.7759/cureus.18044] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 09/17/2021] [Indexed: 11/24/2022] Open
Abstract
Background Severe patient prosthesis mismatch (sPPM) after surgical aortic valve replacement is associated with worse outcomes. Limited data exists on the impact of sPPM on outcomes after transcatheter aortic valve replacement (TAVR), especially regarding the newer generation valves. The aim of this study was to evaluate the incidence, determinants, and outcomes of sPPM in patients undergoing TAVR with Edwards SAPIEN XT (ES XT) and Edwards SAPIEN 3 (ES3) valves (Edwards Lifesciences, Irvine, CA, USA). Methods We retrospectively reviewed 366 patients who underwent TAVR with ES XT (n = 114) or ES3 (n = 252) valves between July 2012 and June 2018. sPPM was defined as indexed effective orifice area (iEOA) <0.65 cm2/m2. Kaplan-Meier survival estimates were used to determine outcomes. Results Multivariate linear regression analysis was utilized to determine potential independent effects of PPM on outcomes. sPPM was present in 40 (11%) of the patients [8 (7%) ES XT and 32 (13%) ES3] and was associated with female sex, smaller left ventricular outflow tract (LVOT) diameter and aortic valve annular area, absence of prior coronary artery bypass graft (CABG) surgery, shorter height, higher body mass index, and smaller pre-TAVR valve area (all p < 0.05). Among those with ES3 valves, the incidence of sPPM was inversely proportional to the valve size (50%, 25%, 5% and 3% for 20-, 23-, 26- and 29-mm valve sizes, respectively; p < 0.001). At a mean follow-up period of 3.5 ± 1.5 years, there was no difference in all-cause mortality (22.5% vs. 25.6%, p = 0.89) or a composite endpoint of heart failure, arrhythmias, stroke, and myocardial infarction (30% vs. 34%, p = 0.24) in those with or without sPPM. Conclusion ES3 was associated with a higher incidence of sPPM, particularly with smaller valve sizes. However, the presence of sPPM as defined by iEOA was not an independent predictor of adverse outcomes in patients undergoing TAVR within an intermediate follow-up period.
Collapse
Affiliation(s)
| | - Marsel Matka
- Cardiology, St. Luke's University Health Network, Bethlehem, USA
| | - Vivek Modi
- Cardiology, St. Luke's University Health Network, Bethlehem, USA
| | - Matthew Carey
- Internal Medicine, St. Luke's University Health Network, Bethlehem, USA
| | | | - Raymond Durkin
- Interventional Cardiology, St. Luke's University Health Network, Bethlehem, USA
| | - Stephen Olenchock
- Cardiac Surgery, St. Luke's University Health Network, Bethlehem, USA
| | - Mehdi Razzaghi
- Statistics, Bloomsburg University of Pennsylvania, Bloomsburg, USA
| | - Jamshid Shirani
- Cardiology, St. Luke's University Health Network, Bethlehem, USA
| |
Collapse
|
11
|
Nitta K, Fukuda Y, Susawa H, Ikenaga H, Utsunomiya H, Ishibashi K, Kurisu S, Takahashi S, Nakano Y, Awai K, Sueda T, Kihara Y. Impact of Prosthesis-Patient Mismatch After Transcatheter Aortic Valve Replacement on Changes in Cardiac Sympathetic Nervous Function. Int Heart J 2020; 61:1188-1195. [PMID: 33191358 DOI: 10.1536/ihj.20-381] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/18/2022]
Abstract
The impact of prosthesis-patient mismatch (PPM) after transcatheter aortic valve replacement (TAVR) on changes in cardiac sympathetic nervous (CSN) function remains unclear. Using 123I-metaiodobenzylguanidine (MIBG) myocardial scintigraphy, we investigated the impact of PPM after TAVR on CSN activity.We enrolled 44 of 117 patients with severe aortic stenosis who underwent TAVR for analysis in the present study. We conducted 123I-MIBG scintigraphy at baseline and at about 9 months after TAVR. Differences between baseline and post-TAVR 123I-MIBG parameters were compared between cases with and without PPM.There were 17 and 27 patients with and without PPM, respectively. Those without PPM exhibited significantly decreased left ventricular mass index (122 ± 36 g/m2 versus 108 ± 30 g/m2, P < 0.001) following TAVR, whereas those with PPM did not (117 ± 21 g/m2 versus 110 ± 17 g/m2, P = 0.09). Significant improvements in delayed heart-to-mediastinum (H/M) ratio (2.8 ± 0.4 versus 3.0 ± 0.4, P = 0.004) and washout rate (WR) (33% ± 10% versus 24% ± 12%, P < 0.001) were observed after TAVR in patients without PPM but not in those with PPM. Multivariable linear regression analysis revealed PPM to be a negative predictor of improvements in delayed H/M ratio and WR.Delayed H/M ratio and WR improve significantly after TAVR in the absence of PPM, whereas these improvements are not observed in patients with PPM. Hence, the presence of PPM is a negative predictor of improvements in delayed H/M ratio and WR in patients undergoing TAVR.
Collapse
Affiliation(s)
- Kazuhiro Nitta
- Department of Cardiovascular Medicine, Hiroshima University Graduate School of Biomedical and Health Sciences
| | - Yukihiro Fukuda
- Department of Cardiovascular Medicine, Hiroshima University Graduate School of Biomedical and Health Sciences
| | - Hitoshi Susawa
- Department of Cardiovascular Medicine, Hiroshima University Graduate School of Biomedical and Health Sciences
| | - Hiroki Ikenaga
- Department of Cardiovascular Medicine, Hiroshima University Graduate School of Biomedical and Health Sciences
| | - Hiroto Utsunomiya
- Department of Cardiovascular Medicine, Hiroshima University Graduate School of Biomedical and Health Sciences
| | - Ken Ishibashi
- Department of Cardiovascular Medicine, Hiroshima University Graduate School of Biomedical and Health Sciences
| | - Satoshi Kurisu
- Department of Cardiovascular Medicine, Hiroshima University Graduate School of Biomedical and Health Sciences
| | - Shinya Takahashi
- Department of Cardiovascular Surgery, Hiroshima University Graduate School of Biomedical and Health Sciences
| | - Yukiko Nakano
- Department of Cardiovascular Medicine, Hiroshima University Graduate School of Biomedical and Health Sciences
| | - Kazuo Awai
- Department of Diagnostic Radiology, Hiroshima University Graduate School of Biomedical and Health Sciences
| | - Taijiro Sueda
- Department of Cardiovascular Surgery, Hiroshima University Graduate School of Biomedical and Health Sciences
| | - Yasuki Kihara
- Department of Cardiovascular Medicine, Hiroshima University Graduate School of Biomedical and Health Sciences
| |
Collapse
|
12
|
Simonato M, Dvir D. The Ten Commandments of Aortic Valve-in-Valve. INNOVATIONS-TECHNOLOGY AND TECHNIQUES IN CARDIOTHORACIC AND VASCULAR SURGERY 2020; 15:397-405. [PMID: 32955362 DOI: 10.1177/1556984520951874] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022]
Affiliation(s)
- Matheus Simonato
- 28105 Escola Paulista de Medicina Universidade Federal de São Paulo, Brazil
| | - Danny Dvir
- 26743 Jesselson Integrated Heart Centre, ShaareZedek Medical Center, Hebrew University, Jerusalem, Israel.,Division of Cardiology, University of Washington, Seattle, WA, USA
| |
Collapse
|
13
|
He S, Fang Z. Incidence, predictors, and outcome of prosthesis-patient mismatch after transcatheter aortic valve replacement: A meta-analysis. Medicine (Baltimore) 2020; 99:e20717. [PMID: 32541522 PMCID: PMC7302587 DOI: 10.1097/md.0000000000020717] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/13/2019] [Revised: 04/14/2020] [Accepted: 05/09/2020] [Indexed: 11/30/2022] Open
Abstract
BACKGROUND Prosthesis-patient mismatch (PPM) following transcatheter aortic valve replacement (TAVR) is common, but the incidence, predictors and outcome of PPM are still controversial. METHODS A total of 18 articles incorporating 72,016 patients were identified form PubMed and Embase online database. RESULTS The pooled incidences of overall, and severe PPM following TAVR were 32.0% and 10.0% separately. Comparing to surgical aortic valve replacement (SAVR), TAVR had lower incidence of overall (OR, 0.31, 95% CI, 0.20-0.50) and severe PPM (OR, 0.38, 95% CI, 0.28-0.52). PPM was associated with a larger body surface area (BSA), larger body mass index (BMI) and previous myocardial infarction in comparison with those patients without PPM. Although PPM was not rare after TAVR, no significant differences were observed both in short- and mid-term all-cause mortality (30 day: OR: 1.51, 95% CI, 0.79-2.87, 1 year: OR: 1.02, 95% CI, 0.96-1.08, and 2 years: OR: 0.99, 95% CI, 0.79-1.24) between patients with PPM and those without PPM. CONCLUSIONS Despite the fact that the incidence of PPM was lower than that of SAVR, PPM was not seen to have an impact on short- and mid-term survival.
Collapse
|
14
|
Coti I, Haberl T, Scherzer S, Shabanian S, Binder T, Kocher A, Laufer G, Andreas M. Rapid-Deployment Aortic Valves for Patients With a Small Aortic Root: A Single-Center Experience. Ann Thorac Surg 2020; 110:1549-1556. [PMID: 32205113 DOI: 10.1016/j.athoracsur.2020.02.030] [Citation(s) in RCA: 21] [Impact Index Per Article: 4.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/15/2019] [Revised: 11/28/2019] [Accepted: 02/04/2020] [Indexed: 11/24/2022]
Abstract
BACKGROUND Aortic valve replacement in patients with a small aortic root is a matter of concern in terms of prosthesis-patient mismatch. We evaluated the survival and hemodynamic performance after implantation of a small rapid-deployment aortic valve (EDWARDS INTUITY valve system sizes 19 and 21 mm). METHODS Between May 2010 and November 2018, 659 consecutive patients with severe aortic stenosis who received a rapid-deployment valve were included in a prospective and ongoing database. A small aortic bioprosthesis (sizes 19 mm and 21 mm) was implanted in 217 (32.9%) patients (mean age 74.9 ± 7.9 years, 85.3% women). Preoperative characteristics, operative parameters, and postoperative outcomes were assessed. RESULTS Mean gradients at discharge and 1 year were 14.8 ± 5.6 mm Hg and 13.6 ± 4.9 mm Hg, respectively. Mean effective orifice area and the indexed effective orifice area at discharge were 1.55 ± 0.36 cm2 and 0.87 ± 0.22 cm2/m2, respectively, and prosthesis-patient mismatch occurred in 77 (35.5%) patients (25.8% moderate and 9.7% severe). Perioperative mortality was 1.8% (n = 4 of 217) and overall survival at 1 year and 5 years was 91% and 79%, respectively. The presence of any prosthesis-patient mismatch degree did not have a significant influence on overall survival (hazard ratio, 0.95; 95% confidence interval, 0.75-1.19; P = .638). At the last follow-up, mean New York Heart Association functional class was 1.5 ± 0.7 vs 2.8 ± 0.6 at baseline (P < .001). CONCLUSIONS Surgical aortic valve replacement with rapid-deployment valves has shown improved results concerning hemodynamic performance, with decreased rates of prosthesis-patient mismatch. We observed excellent early-term and midterm survival and a significant improvement in functional class in this subgroup of patients with a small annulus.
Collapse
Affiliation(s)
- Iuliana Coti
- Division of Cardiac Surgery, Department of Surgery, Medical University of Vienna, Vienna, Austria
| | - Thomas Haberl
- Division of Cardiac Surgery, Department of Surgery, Medical University of Vienna, Vienna, Austria
| | - Sabine Scherzer
- Division of Cardiac Surgery, Department of Surgery, Medical University of Vienna, Vienna, Austria
| | - Shiva Shabanian
- Division of Cardiac Surgery, Department of Surgery, Medical University of Vienna, Vienna, Austria
| | - Thomas Binder
- Division of Cardiology, Department of Internal Medicine II, Medical University of Vienna, Vienna, Austria
| | - Alfred Kocher
- Division of Cardiac Surgery, Department of Surgery, Medical University of Vienna, Vienna, Austria
| | - Guenther Laufer
- Division of Cardiac Surgery, Department of Surgery, Medical University of Vienna, Vienna, Austria
| | - Martin Andreas
- Division of Cardiac Surgery, Department of Surgery, Medical University of Vienna, Vienna, Austria.
| |
Collapse
|
15
|
Comparison of patient-prothesis mismatch after surgical aortic valve replacement and transcatheter aortic valve implantation. TURK GOGUS KALP DAMAR CERRAHISI DERGISI-TURKISH JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY 2020; 27:143-151. [PMID: 32082845 DOI: 10.5606/tgkdc.dergisi.2019.17174] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/04/2018] [Accepted: 12/03/2018] [Indexed: 11/21/2022]
Abstract
Background The aim of this study is to analyze the outcomes and incidence of postoperative patient-prothesis mismatch after surgical aortic valve replacement using supra-annular bioprosthesis and transcatheter aortic valve implantation. Methods Between January 2012 and June 2015, a total of 73 patients (37 males, 36 females; mean age 71.8±5.7 years; range, 65 to 82 years) who underwent either surgical aortic valve replacement using supraannular bioprosthesis (n=36) or transcatheter aortic valve implantation (n=37) were included. Postoperative patient-prothesis mismatch was defined as absent, mild-to-moderate, and severe, if the indexed effective orifice area was >0.85 cm2/m2, >0.65 to <0.85 cm2/m2, and <0.65 cm2/m2, respectively. Both groups were compared in terms of patient-prothesis mismatch, postoperative outcomes, and mortality. Results The overall incidence of mild-to-moderate patient-prosthesis mismatch was 17.8% (13/73). No severe patient-prosthesis mismatch was observed. Mild-to-moderate patient-prosthesis mismatch was found in three patients (8.1%) in the transcatheter group and in 10 patients (27.8%) in the surgery group (p=0.035). Body surface area was the significant predictor of patient-prosthesis mismatch (p=0.007). Diameters of bioprosthetic valves in the surgery and transcatheter groups were 21.4±2 and 23.9±2.6 mm, respectively (p=0.002). Early mortality and pacemaker implantation rates were higher in the transcatheter group (p>0.05). Postoperative outcomes were similar between the groups. Mid-term mortality at a mean follow-up of 47.7±7.3 months was similar between the groups (p=0.158). Conclusion In high-risk patients with severe aortic stenosis, patientprosthesis mismatch is mild-to-moderate after surgical aortic valve replacement and transcatheter aortic valve implantation; however, this has no effect on early mortality. Based on our study results, we suggest that the use of surgical approach for aortic valve replacement may prevent potential complications of transcatheter aortic valve implantation.
Collapse
|
16
|
Komarov R, Chernov I, Enginoev S, Sá MPBO, Tarasov D. The Russian Conduit - Combining Bentall and Ozaki Procedures for Concomitant Ascending Aorta Replacement and Aortic Valve Neocuspidization. Braz J Cardiovasc Surg 2019; 34:618-623. [PMID: 31719014 PMCID: PMC6852441 DOI: 10.21470/1678-9741-2019-0329] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/18/2022] Open
Abstract
In aortic valve disease cases, prosthetic valves have been used for valve
replacement, however, these prostheses have inherent problems, and their quality
in some countries is lower comparing to new-generation models, causing shorter
durability. Aortic valve neocuspidization (AVNeo) has emerged as an option,
which can be applied to a wide spectrum of these diseases. Despite the promising
results, this procedure is not widely spread among cardiac surgeons yet. We
developed a surgical technique combining Bentall and Ozaki procedures to treat
patients with concomitant ascending aorta replacement and AVNeo and we describe
it in this paper. The Russian conduit – combination of Bentall and Ozaki
procedures. ![]()
Collapse
Affiliation(s)
- Roman Komarov
- Sechenov First Moscow State Medical University of Health Ministry of Russia Clinic of Aortic and Cardiovascular Surgery Moscow Russia Clinic of Aortic and Cardiovascular Surgery, Sechenov First Moscow State Medical University of Health Ministry of Russia, Moscow, Russia
| | - Igor Chernov
- Federal Center for Cardiovascular Surgery Department of Cardiac Surgery Russia Department of Cardiac Surgery, Federal Center for Cardiovascular Surgery, Russia
| | - Soslan Enginoev
- Astrakhan State Medical University Astrakhan Russia Astrakhan State Medical University, Astrakhan, Russia
| | - Michel Pompeu B O Sá
- Pronto-Socorro Cardiológico de Pernambuco - Prof. Luiz Tavares Division of Cardiovascular Surgery Recife Brazil Division of Cardiovascular Surgery, Pronto-Socorro Cardiológico de Pernambuco - Prof. Luiz Tavares, PROCAPE, Recife, Brazil.,University of Pernambuco Recife Brazil University of Pernambuco, UPE, Recife, Brazil.,Faculty of Medical Sciences and Biological Sciences Institute Nucleus of Postgraduate and Research in Health Sciences Recife Brazil Nucleus of Postgraduate and Research in Health Sciences of Faculty of Medical Sciences and Biological Sciences Institute, FCM/ICB, Recife, Brazil
| | - Dmitry Tarasov
- Astrakhan State Medical University Astrakhan Russia Astrakhan State Medical University, Astrakhan, Russia
| |
Collapse
|
17
|
Maeda K, Kuratani T, Yoshioka D, Pak K, Shimamura K, Toda K, Sawa Y. Predicting patient–prosthesis mismatch by aortic root evaluation before aortic valve replacement. J Thorac Cardiovasc Surg 2019; 158:61-69.e4. [DOI: 10.1016/j.jtcvs.2018.11.103] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/25/2017] [Revised: 11/08/2018] [Accepted: 11/25/2018] [Indexed: 11/30/2022]
|
18
|
León del Pino MDC, Ruíz Ortiz M, Delgado Ortega M, Sánchez Fernández J, Ferreiro Quero C, Durán Jiménez E, Romero Moreno M, Segura Saint-Gerons J, Ojeda Pineda S, Pan Álvarez-Ossorio M, Mesa Rubio D. Prosthesis-patient mismatch after transcatheter aortic valve replacement: prevalence and medium term prognostic impact. Int J Cardiovasc Imaging 2019; 35:827-836. [DOI: 10.1007/s10554-018-01519-z] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/19/2018] [Accepted: 12/24/2018] [Indexed: 01/01/2023]
|
19
|
Tadokoro N, Fukushima S, Shimahara Y, Matsumoto Y, Yamashita K, Kawamoto N, Minami K, Kobayashi J, Fujita T. Trifecta vs. Magna for Aortic Valve Replacement - Differences in Clinical Outcome and Valve Hemodynamics. Circ J 2018; 82:2767-2775. [PMID: 30224571 DOI: 10.1253/circj.cj-18-0744] [Citation(s) in RCA: 18] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/05/2024]
Abstract
BACKGROUND The number of surgical aortic valve replacements using bioprosthetic valves is increasing, and newer bioprosthetic valves may offer clinical advantages in Japanese patients, who generally require smaller replacement valves than Western patients. In this study we retrospectively evaluated the Trifecta and Magna valves to compare clinical outcomes and hemodynamics in a group of Japanese patients. METHODS AND RESULTS Data were retrospectively collected for 103 patients receiving a Trifecta valve and 356 patients receiving a Magna valve between June 2008 and 2017. Adverse events, outcomes, and valve hemodynamics were evaluated. There were no significant differences in early or late outcomes between the Trifecta and Magna groups. In the early postoperative period, mean (±SD) pressure gradient (9.0±3.1 vs. 13.8±4.8 mmHg; P<0.01) and effective orifice area (1.68±0.46 vs. 1.46±0.40 m2; P<0.01) were significantly better for Trifecta, but the differences decreased over time. In particular, the interaction between time and valve type (Trifecta or Magna) was significantly different for mean pressure gradient between the 2 groups (P<0.01). Left ventricular mass regressed substantially in both groups, with no significant difference between them. There were no significant differences for severe patient-prosthesis mismatch. CONCLUSIONS Postoperative outcomes were similar for both valves. An early hemodynamic advantage for the Trifecta valve lasted to approximately 1 year postoperatively but did not persist.
Collapse
Affiliation(s)
- Naoki Tadokoro
- Department of Cardiovascular Surgery, National Cerebral and Cardiovascular Center
| | - Satsuki Fukushima
- Department of Cardiovascular Surgery, National Cerebral and Cardiovascular Center
| | - Yusuke Shimahara
- Department of Cardiovascular Surgery, National Cerebral and Cardiovascular Center
| | - Yorihiko Matsumoto
- Department of Cardiovascular Surgery, National Cerebral and Cardiovascular Center
| | - Kizuku Yamashita
- Department of Cardiovascular Surgery, National Cerebral and Cardiovascular Center
| | - Naonori Kawamoto
- Department of Cardiovascular Surgery, National Cerebral and Cardiovascular Center
| | - Kimito Minami
- Department of Surgical Intensive Care, National Cerebral and Cardiovascular Center
| | - Junjiro Kobayashi
- Department of Cardiovascular Surgery, National Cerebral and Cardiovascular Center
| | - Tomoyuki Fujita
- Department of Cardiovascular Surgery, National Cerebral and Cardiovascular Center
| |
Collapse
|
20
|
Akuffu AM, Zhao H, Zheng J, Ni Y. Prosthesis-patient mismatch after mitral valve replacement: a single-centered retrospective analysis in East China. J Cardiothorac Surg 2018; 13:100. [PMID: 30285794 PMCID: PMC6169081 DOI: 10.1186/s13019-018-0788-4] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/14/2018] [Accepted: 09/25/2018] [Indexed: 11/30/2022] Open
Abstract
Background Prosthesis–patient mismatch (PPM) may affect the clinical outcomes of patients undergoing mitral valve replacement (MVR) surgery. We aimed to investigate the incidence of PPM of the mitral position in our center and analyze the possible predictors of PPM as well as its effect on short-term outcomes. Methods We retrospectively examined all consecutive patients with isolated or concomitant MVR at our center from 2013 to 2015. PPM was defined as an indexed effective orifice area (iEOA) of ≤1.2 cm2/m2. After inclusion and exclusion, a total of 1067 patients were analyzed. The baseline information were collected and compared between the two groups. Multivariate logistic regression analysis was conducted to determine the preoperative predictors of PPM as well as the effect of PPM on early mortality. Results A total of 1067 patients were included in the study. PPM was detected in 15.9% of the patients while 12 patients (1.12%) met the criteria for severe PPM. Patients with PPM compared to the non-PPM patients had higher age, larger body surface area and were more likely to be male and obese. Logistic regression analysis showed that higher age, larger BSA, bioprosthesis and smaller left ventricle end-diastolic diameter were predictors of PPM. There were no significant differences between the PPM and non-PPM groups regarding post-operative complications. Logistic regression analysis showed that PPM was not a risk factor of short-term mortality (P = 0.654). Also, there were no significant differences regarding short−/mid-term heart function between the PPM and non PPM groups (P = 0.902). Conclusions Our results demonstrated that higher age, bioprosthesis, larger BSA and smaller left ventricle size were associated with mitral PPM. However, PPM was not associated with poorer early outcomes after MVR surgery. In eastern of China, the prevalence of mitral valve stenosis is high; therefore, whether the standard PPM criteria are suitable for patients of this district needs to be further verified.
Collapse
Affiliation(s)
- Armah M Akuffu
- Department of Cardiothoracic Surgery, the First Affiliated Hospital of Zhejiang University, No.79 Qingchun Road, Hangzhou, 310003, China
| | - Haige Zhao
- Department of Cardiothoracic Surgery, the First Affiliated Hospital of Zhejiang University, No.79 Qingchun Road, Hangzhou, 310003, China
| | - Junnan Zheng
- Department of Cardiothoracic Surgery, the First Affiliated Hospital of Zhejiang University, No.79 Qingchun Road, Hangzhou, 310003, China.
| | - Yiming Ni
- Department of Cardiothoracic Surgery, the First Affiliated Hospital of Zhejiang University, No.79 Qingchun Road, Hangzhou, 310003, China
| |
Collapse
|
21
|
Junquera L, Ferreira-Neto A, Guimaraes L, Asmarats L, Del Val D, Wintzer-Wehekind J, Muntané-Carol G, Freitas-Ferraz A, Rodés-Cabau J. Transcatheter aortic valve replacement in low risk patients. Minerva Cardioangiol 2018; 67:19-38. [PMID: 30260144 DOI: 10.23736/s0026-4725.18.04783-7] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
Abstract
Transcatheter aortic valve replacement (TAVR) is a relatively new technology that has grown exponentially over the past decade. Although it was initially restricted to elderly patients at very high or prohibitive surgical risk, it is currently being evaluated as a treatment option in younger and lower risk patients. The increasing experience of the Heart Teams, along with the continued refinement of transcatheter valve technology has resulted in TAVR achieving results comparable to those of surgery for treating intermediate-risk patients. Furthermore, promising preliminary results have been obtained from observational and propensity matched studies in low risk patients, and a small randomized trial showed the non-inferiority of TAVR vs. SAVR regarding early and late (up to 6 years) outcomes. Three ongoing randomized trials will provide the definite response about the safety and efficacy of TAVR for treating low risk patients with severe aortic stenosis in the near future. The (expected) positive results of these studies would establish the basis for TAVR as the preferred treatment for the majority of patients with aortic stenosis. However, continuous research efforts for better determining valve durability among TAVR recipients, as well as reducing some of the genuine and frequent complications of TAVR (e.g. conduction disturbances) are important in this final effort for making TAVR the default treatment for aortic stenosis.
Collapse
Affiliation(s)
- Lucia Junquera
- Quebec Heart and Lung Institute, Laval University, Quebec City, Quebec, Canada
| | | | - Leonardo Guimaraes
- Quebec Heart and Lung Institute, Laval University, Quebec City, Quebec, Canada
| | - Lluis Asmarats
- Quebec Heart and Lung Institute, Laval University, Quebec City, Quebec, Canada
| | - David Del Val
- Quebec Heart and Lung Institute, Laval University, Quebec City, Quebec, Canada
| | | | | | | | - Josep Rodés-Cabau
- Quebec Heart and Lung Institute, Laval University, Quebec City, Quebec, Canada -
| |
Collapse
|
22
|
Klautz RJM, Kappetein AP, Lange R, Dagenais F, Labrousse L, Bapat V, Moront M, Misfeld M, Zeng C, Sabik Iii JF. Safety, effectiveness and haemodynamic performance of a new stented aortic valve bioprosthesis. Eur J Cardiothorac Surg 2018; 52:425-431. [PMID: 28475690 PMCID: PMC5848807 DOI: 10.1093/ejcts/ezx066] [Citation(s) in RCA: 32] [Impact Index Per Article: 4.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/07/2016] [Accepted: 02/07/2017] [Indexed: 11/14/2022] Open
Abstract
OBJECTIVES We assessed the safety, effectiveness and haemodynamic performance of a new bovine stented aortic valve bioprosthesis (Avalus™). METHODS The PERIGON Pivotal Trial is a prospective, non-randomized, multicentre study. Subjects had symptomatic moderate or severe aortic stenosis or chronic, severe aortic regurgitation. Death, valve-related adverse events (AEs), functional recovery and haemodynamic performance were assessed at discharge, 3-6 months and 1 year. The primary analysis compared 'late' (>30 days post-implant) linearized rates of valve-related thromboembolism, thrombosis, all and major haemorrhage, all and major paravalvular leak (PVL) and endocarditis after implantation with objective performance criteria (OPC) for AEs, in accordance with EN ISO 5840:2009. We hypothesized that the upper 95% confidence bounds of the true linearized AE rates would be ≥ 2 × OPC; rejection of the null hypothesis would demonstrate that these rates were below acceptable rates. The analysis was required to include at least 150 patients followed to 1 year and 400 valve-years. Kaplan-Meier survival analysis was also performed. RESULTS Total number of valve-years was 459.5 (n = 686). Linearized rates were <2 × OPC for death and valve-related thromboembolism, valve thrombosis, all and major PVL, and endocarditis, but ≥2 × OPC for all and major haemorrhage. Survival at 1 year (n = 270) was 96.4%. Patients showed good functional recovery, and haemodynamic performance was within expected range. CONCLUSIONS This analysis demonstrated a good safety profile and clinical effectiveness of the Avalus valve except for bleeding rates. The linearized rates of all and major haemorrhage may be related to long-term anticoagulation for non-valvular indications and the length of follow-up of this cohort. Trial registration NCT02088554 (www.clinicaltrials.gov).
Collapse
Affiliation(s)
- Robert J M Klautz
- Department of Cardiothoracic Surgery, Leiden University Medical Centre, Leiden, Netherlands
| | - A Pieter Kappetein
- Department of Cardio-Thoracic Surgery, Erasmus Medical Centre, Rotterdam, Netherlands
| | - Rüdiger Lange
- German Heart Centre, Technical University of Munich, Munich, Germany
| | - Francois Dagenais
- Deparment of Cardiac Surgery, Québec Heart and Lung Institute, Québec City, Canada
| | - Louis Labrousse
- Department of Cardiac and Vascular Surgery, University Hospital of Bordeaux, Bordeaux, France
| | - Vinayak Bapat
- Department of Cardiothoracic Surgery, St Thomas' Hospital, London, UK
| | - Michael Moront
- Department of Cardiothoracic Surgery, ProMedica Toledo Hospital, Toledo, OH, USA
| | - Martin Misfeld
- Department of Cardiac Surgery, Leipzig Heart Centre, University Hospital, Leipzig, Germany
| | - Cathy Zeng
- Statistical Services Department, Medtronic, Minneapolis, MN, USA
| | - Joseph F Sabik Iii
- Department of Surgery, University Hospitals, Cleveland Medical Center, Case Western Reserve University School of Medicine, Cleveland, OH, USA
| | | |
Collapse
|
23
|
Belluschi I, Moriggia S, Giacomini A, Del Forno B, Di Sanzo S, Blasio A, Scafuri A, Alfieri O. Can Perceval sutureless valve reduce the rate of patient-prosthesis mismatch?†. Eur J Cardiothorac Surg 2018; 51:1093-1099. [PMID: 28329177 DOI: 10.1093/ejcts/ezx009] [Citation(s) in RCA: 27] [Impact Index Per Article: 3.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/30/2016] [Accepted: 12/17/2016] [Indexed: 11/13/2022] Open
Abstract
OBJECTIVES The aim of this study is to compare the theoretical incidence of patient-prosthesis mismatch (PPM) in patients undergoing a sutureless or a sutured aortic valve replacement using an exact statistical matching. METHODS Between May 2012 and March 2016, 65 patients with severe symptomatic aortic stenosis underwent a sutureless aortic valve replacement with the Perceval bioprosthesis in 2 centres. Moreover, 177 aortic valve replacements with conventional sutured bioprosthesis were performed between August 2003 and September 2015. Perceval and sutured patients were 1:1 exactly matched for sex and body surface area (BSA), resulting in 62 couples (sutureless: BSA 1.77 ± 0.16 m 2 , female 62.9% vs sutured: BSA 1.77 ± 0.15 m 2 , female 62.9%). RESULTS After matching, the indexed effective orifice area was 1.50 ± 0.18 cm 2 /m 2 and 0.81 ± 0.19 cm 2 /m 2 in the sutureless and the sutured group, respectively ( P < 0.001). No PPM occurred in patients who received a Perceval bioprosthesis ( n = 62). In the sutured group ( n = 62), 38 patients (61.3%) developed a PPM, which was moderate in 41.9% ( n = 26) and severe in 19.4% ( n = 12) ( P < 0.001). CONCLUSIONS The indexed effective orifice area of the sutureless group was significantly larger than in the sutured one. The incidence of PPM with the conventional sutured biprosthesis was 61.3%, while it decreases to 0% in the sutureless group. No PPM was reported in the sutureless valve group. Therefore, the Perceval sutureless valve provides larger effective orifice areas compared to the sutured conventional bioprosthesis and could be considered as a good option to reduce the risk of a PPM.
Collapse
Affiliation(s)
- Igor Belluschi
- Department of Cardiac Surgery, San Raffaele University Hospital, Milan, Italy
| | - Stefano Moriggia
- Department of Cardiac Surgery, San Raffaele University Hospital, Milan, Italy
| | - Andrea Giacomini
- Department of Cardiac Surgery, San Raffaele University Hospital, Milan, Italy
| | - Benedetto Del Forno
- Department of Cardiac Surgery, San Raffaele University Hospital, Milan, Italy
| | - Stefania Di Sanzo
- Department of Cardiac Surgery, San Raffaele University Hospital, Milan, Italy
| | - Andrea Blasio
- Department of Cardiac Surgery, San Raffaele University Hospital, Milan, Italy
| | - Antonio Scafuri
- Department of Cardiac Surgery, Tor Vergata University of Rome, Rome, Italy
| | - Ottavio Alfieri
- Department of Cardiac Surgery, San Raffaele University Hospital, Milan, Italy
| |
Collapse
|
24
|
Nakashima M, Watanabe Y. Transcatheter Aortic Valve Implantation in Small Anatomy: Patient Selection and Technical Challenges. Interv Cardiol 2018; 13:66-68. [PMID: 29928310 DOI: 10.15420/icr.2017:28:1] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/18/2022] Open
Abstract
Transcatheter aortic valve implantation (TAVI) has become a standard treatment for severe aortic stenosis. Although this technique has reached relative maturity, further optimisation of patient selection and device implantation is essential to improve prognosis. Smaller body size is a predictor of a challenging TAVI procedure due to specific anatomical difficulty and adverse events including annulus rupture, acute coronary obstruction and vascular complications. A newer generation, lower profile TAVI system is useful for patients with smaller anatomy. Moreover, TAVI is superior to surgical aortic valve replacement in patients with a narrowing annulus because this treatement has a low incidence of prosthesis-patient mismatch.
Collapse
Affiliation(s)
- Makoto Nakashima
- Department of Medicine, Teikyo University School of Medicine, Tokyo, Japan
| | - Yusuke Watanabe
- Department of Medicine, Teikyo University School of Medicine, Tokyo, Japan
| |
Collapse
|
25
|
Liao YB, Li YJ, Jun-Li L, Zhao ZG, Wei X, Tsauo JY, Xiong TY, Xu YN, Feng Y, Chen M. Incidence, Predictors and Outcome of Prosthesis-Patient Mismatch after Transcatheter Aortic Valve Replacement: a Systematic Review and Meta-analysis. Sci Rep 2017; 7:15014. [PMID: 29118326 PMCID: PMC5678180 DOI: 10.1038/s41598-017-15396-4] [Citation(s) in RCA: 21] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/09/2017] [Accepted: 10/26/2017] [Indexed: 02/05/2023] Open
Abstract
The aim of this study was to investigate the incidence, predictors and outcome of prosthesis-patient mismatch (PPM) following transcatheter aortic valve replacement (TAVR). A total of 30 articles incorporating 4,691 patients were identified. The pooled incidences of overall, moderate and severe PPM following TAVR were 33.0%, 25.0% and 11.0% respectively. Medtronic CoreValve (MCV) had lower incidence of overall (32% vs: 40%, P < 0.0001) and moderate (23% vs 32%, P < 0.0001) than Edwards Sapien (ESV). PPM was associated with a younger age, smaller annulus diameter and lower left ventricular ejection fraction in comparison with those patients without PPM. Post-dilation (OR, 0.51, 95% CI, 0.38 to 0.68, p < 0.001) during TAVR would decrease the incidence of PPM. Although PPM was common after TAVR, no significant differences were observed both in short- and mid-term all-cause mortality (30 day: OR: 1.1, 95% CI, 0.70 to 1.73 and 2 year: OR: 1.01, 95% CI, 0.74 to 1.38) between patients with PPM and those without PPM. In conclusion, despite being common after TAVR, the incidence of PPM was lower than that of surgical aortic valve replacement (SAVR) and decreased with the experience accumulating, and PPM was not seen to impact on short- and mid-term survival, regardless of its magnitude.
Collapse
Affiliation(s)
- Yan-Biao Liao
- Department of Cardiology, West China Hospital, Sichuan University, 37 Guoxue Street, Chengdu, 610041, P. R. China
| | - Yi-Jian Li
- Department of Cardiology, West China Hospital, Sichuan University, 37 Guoxue Street, Chengdu, 610041, P. R. China
| | - Li Jun-Li
- Department of Cardiology, West China Hospital, Sichuan University, 37 Guoxue Street, Chengdu, 610041, P. R. China
| | - Zhen-Gang Zhao
- Department of Cardiology, West China Hospital, Sichuan University, 37 Guoxue Street, Chengdu, 610041, P. R. China
| | - Xin Wei
- Department of Cardiology, West China Hospital, Sichuan University, 37 Guoxue Street, Chengdu, 610041, P. R. China
| | - Jiay-Yu Tsauo
- Department of Cardiology, West China Hospital, Sichuan University, 37 Guoxue Street, Chengdu, 610041, P. R. China
| | - Tian-Yuan Xiong
- Department of Cardiology, West China Hospital, Sichuan University, 37 Guoxue Street, Chengdu, 610041, P. R. China
| | - Yuan-Ning Xu
- Department of Cardiology, West China Hospital, Sichuan University, 37 Guoxue Street, Chengdu, 610041, P. R. China
| | - Yuan Feng
- Department of Cardiology, West China Hospital, Sichuan University, 37 Guoxue Street, Chengdu, 610041, P. R. China.
| | - Mao Chen
- Department of Cardiology, West China Hospital, Sichuan University, 37 Guoxue Street, Chengdu, 610041, P. R. China.
| |
Collapse
|
26
|
Lee SH, Chang BC, Youn YN, Joo HC, Yoo KJ, Lee S. Impact of prosthesis-patient mismatch after mitral valve replacement in rheumatic population: Does mitral position prosthesis-patient mismatch really exist? J Cardiothorac Surg 2017; 12:88. [PMID: 29017586 PMCID: PMC5635500 DOI: 10.1186/s13019-017-0653-x] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/29/2017] [Accepted: 10/05/2017] [Indexed: 01/20/2023] Open
Abstract
Background Prosthesis-patient mismatch (PPM) is characterised by the effects of inadequate prosthesis size relative to body surface area (BSA).The purpose of this study was to determine the impact of PPM on late clinical outcomes after mitral valve replacement (MVR) in rheumatic population. Methods From 2000 to 2013, a total of 445 patients (mean age 54.2 ± 11.7 years) underwent isolated MVR (±tricuspid annuloplasty) for rheumatic disease were investigated. Effective orifice area (EOA) was determined by the continuity equation and PPM was defined as indexed EOA (EOA/BSA) ≤ 1.2 cm2/m2. Clinical and echocardiographic follow-up (mean follow up 8.7 ± 4.0 years) results were compared. Results 37% of patients (n = 165) had PPM. There were no significant differences in baseline and operative characteristics between patients with and without PPM except age and IEOA. A significant decrease in mean trans-valvular pressure gradient (MPG) over time following MVR, however the change of MPG showed no differences between groups (No PPM vs. PPM: 8.9 ± 4.7 mmHg → 3.6 ± 1.2 mmHg vs. 8.7 ± 4.5 mmHg → 3.8 ± 1.4 mmHg, p-value = 0.28). In all patients, there was a reduction of left atrium dimension (58.6 ± 12.0 mm → 53.2 ± 12.0 mm vs. 57.9 ± 8.9 mm → 52.2 ± 8.9 mm, p-value = 0.68) and left ventricular end diastolic diameter (49.9 ± 5.7 mm → 48.9 ± 5.7 mm vs. 49.7 ± 6.0 mm → 48.3 ± 5.0 mm, p = 0.24) without statistical significance. Freedom from TR progression rates at 3 and 5 years (99% vs.98%, 99% vs. 98%, p-value = 0.1), and overall survival rates at 3 and 5 years (97% vs. 96%, 94% vs. 94%, p-value = 0.7) were similar. Conclusion This study shows that mitral PPM is not associated with atrial /ventricular remodeling and might not influence late clinical outcome including late TR progression, survival in rheumatic population.
Collapse
Affiliation(s)
- Seung Hyun Lee
- Division of Thoracic and Cardiovascular Surgery, Severance Cardiovascular Hospital, Yonsei Cardiovascular Research Institute, Yonsei University, College of Medicine, 250 Seongsanno, Seodaemun-gu, Seoul, 03722, Republic of Korea
| | - Byung Chul Chang
- Division of Thoracic and Cardiovascular Surgery, Severance Cardiovascular Hospital, Yonsei Cardiovascular Research Institute, Yonsei University, College of Medicine, 250 Seongsanno, Seodaemun-gu, Seoul, 03722, Republic of Korea
| | - Young-Nam Youn
- Division of Thoracic and Cardiovascular Surgery, Severance Cardiovascular Hospital, Yonsei Cardiovascular Research Institute, Yonsei University, College of Medicine, 250 Seongsanno, Seodaemun-gu, Seoul, 03722, Republic of Korea
| | - Hyun Chel Joo
- Division of Thoracic and Cardiovascular Surgery, Severance Cardiovascular Hospital, Yonsei Cardiovascular Research Institute, Yonsei University, College of Medicine, 250 Seongsanno, Seodaemun-gu, Seoul, 03722, Republic of Korea
| | - Kyung-Jong Yoo
- Division of Thoracic and Cardiovascular Surgery, Severance Cardiovascular Hospital, Yonsei Cardiovascular Research Institute, Yonsei University, College of Medicine, 250 Seongsanno, Seodaemun-gu, Seoul, 03722, Republic of Korea
| | - Sak Lee
- Division of Thoracic and Cardiovascular Surgery, Severance Cardiovascular Hospital, Yonsei Cardiovascular Research Institute, Yonsei University, College of Medicine, 250 Seongsanno, Seodaemun-gu, Seoul, 03722, Republic of Korea.
| |
Collapse
|
27
|
Abstract
The prevalence of pregnant women with cardiovascular heart disease is increasing. Transthoracic echocardiography is safe during pregnancy, and it is an important diagnostic tool in pregnant women with established heart disease in order to monitor ventricular and valvular anatomy and function. In addition, it can be used to delineate cardiac anatomy in complex congenital heart disease and help stratify maternal risk during pregnancy. This review will focus on the use of echocardiography in the diagnosis and management of pregnant women with common congenital lesions and with prosthetic valves.
Collapse
Affiliation(s)
- Meena Narayanan
- Division of Cardiology, Department of Medicine, Keck School of Medicine, University of Southern California, Los Angeles, CA, USA
| | - Uri Elkayam
- Division of Cardiology, Department of Medicine, Keck School of Medicine, University of Southern California, Los Angeles, CA, USA
| | - Tasneem Z Naqvi
- Division of Cardiology, Department of Medicine, College of Medicine, Mayo Clinic, CK27, 13400 E Shea Blvd, Scottsdale, AZ, 85259, USA.
| |
Collapse
|
28
|
Dasi LP, Hatoum H, Kheradvar A, Zareian R, Alavi SH, Sun W, Martin C, Pham T, Wang Q, Midha PA, Raghav V, Yoganathan AP. On the Mechanics of Transcatheter Aortic Valve Replacement. Ann Biomed Eng 2017; 45:310-331. [PMID: 27873034 PMCID: PMC5300937 DOI: 10.1007/s10439-016-1759-3] [Citation(s) in RCA: 61] [Impact Index Per Article: 7.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/20/2016] [Accepted: 11/03/2016] [Indexed: 01/22/2023]
Abstract
Transcatheter aortic valves (TAVs) represent the latest advances in prosthetic heart valve technology. TAVs are truly transformational as they bring the benefit of heart valve replacement to patients that would otherwise not be operated on. Nevertheless, like any new device technology, the high expectations are dampened with growing concerns arising from frequent complications that develop in patients, indicating that the technology is far from being mature. Some of the most common complications that plague current TAV devices include malpositioning, crimp-induced leaflet damage, paravalvular leak, thrombosis, conduction abnormalities and prosthesis-patient mismatch. In this article, we provide an in-depth review of the current state-of-the-art pertaining the mechanics of TAVs while highlighting various studies guiding clinicians, regulatory agencies, and next-generation device designers.
Collapse
Affiliation(s)
- Lakshmi P Dasi
- Department of Biomedical Engineering, Dorothy Davis Heart and Lung Research Institute, The Ohio State University, 473 W 12th Avenue, Columbus, OH, 43210, USA.
| | - Hoda Hatoum
- Department of Biomedical Engineering, Dorothy Davis Heart and Lung Research Institute, The Ohio State University, 473 W 12th Avenue, Columbus, OH, 43210, USA
| | - Arash Kheradvar
- The Edwards Lifesciences Center for Advanced Cardiovascular Technology, Department of Biomedical Engineering, University of California, Irvine, CA, 92697, USA
| | - Ramin Zareian
- The Edwards Lifesciences Center for Advanced Cardiovascular Technology, Department of Biomedical Engineering, University of California, Irvine, CA, 92697, USA
| | - S Hamed Alavi
- The Edwards Lifesciences Center for Advanced Cardiovascular Technology, Department of Biomedical Engineering, University of California, Irvine, CA, 92697, USA
| | - Wei Sun
- Wallace H. Coulter Department of Biomedical Engineering, Georgia Institute of Technology, Atlanta, GA, 30332, USA
| | - Caitlin Martin
- Wallace H. Coulter Department of Biomedical Engineering, Georgia Institute of Technology, Atlanta, GA, 30332, USA
| | - Thuy Pham
- Wallace H. Coulter Department of Biomedical Engineering, Georgia Institute of Technology, Atlanta, GA, 30332, USA
| | - Qian Wang
- Wallace H. Coulter Department of Biomedical Engineering, Georgia Institute of Technology, Atlanta, GA, 30332, USA
| | - Prem A Midha
- Wallace H. Coulter Department of Biomedical Engineering, Georgia Institute of Technology, Atlanta, GA, 30332, USA
| | - Vrishank Raghav
- Wallace H. Coulter Department of Biomedical Engineering, Georgia Institute of Technology, Atlanta, GA, 30332, USA
| | - Ajit P Yoganathan
- Wallace H. Coulter Department of Biomedical Engineering, Georgia Institute of Technology, Atlanta, GA, 30332, USA
| |
Collapse
|
29
|
Mannacio V, Mannacio L, Mango E, Antignano A, Mottola M, Caparrotti S, Musumeci F, Vosa C. Severe prosthesis-patient mismatch after aortic valve replacement for aortic stenosis: Analysis of risk factors for early and long-term mortality. J Cardiol 2017; 69:333-339. [DOI: 10.1016/j.jjcc.2016.07.003] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/15/2016] [Revised: 05/18/2016] [Accepted: 07/05/2016] [Indexed: 10/21/2022]
|
30
|
|
31
|
Sportelli E, Regesta T, Salsano A, Ghione P, Brega C, Bezante GP, Passerone G, Santini F. Does patient-prosthesis mismatch after aortic valve replacement affect survival and quality of life in elderly patients? J Cardiovasc Med (Hagerstown) 2016; 17:137-43. [PMID: 26237424 DOI: 10.2459/jcm.0000000000000292] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/05/2022]
Abstract
BACKGROUND To evaluate the impact of patient-prosthesis mismatch (PPM) on survival, functional status, and quality of life (QoL) after aortic valve replacement (AVR) with small prosthesis size in elderly patients. METHODS Between January 2005 and December 2013, 152 patients with pure aortic stenosis, aged at least 75 years, underwent AVR, with a 19 or 21 mm prosthetic heart valve. PPM was defined as an indexed effective orifice area less than 0.85 cm/m. Median age was 82 years (range 75-93 years). Mean follow-up was 56 months (range 1-82 months) and was 98% complete. Late survival rate, New York Heart Association functional class, and QoL (RAND SF-36) were assessed. RESULTS Overall, PPM was found in 78 patients (53.8%). Among them, 42 patients (29%) had an indexed effective orifice area less than 0.75 cm/m and 17 less than 0.65 cm/m (11.7%). Overall survival at 5 years was 78 ± 4.5% and was not influenced by PPM (P = NS). The mean New York Heart Association class for long-term survivors with PPM improved from 3.0 to 1.7 (P < 0.001). QoL (physical functioning 45.18 ± 11.35, energy/fatigue 49.36 ± 8.64, emotional well being 58.84 ± 15.44, social functioning 61.29 ± 6.15) was similar to that of no-PPM patients (P = NS). CONCLUSION PPM after AVR does not affect survival, functional status, and QoL in patients aged at least 75 years. Surgical procedures, often time-consuming, contemplated to prevent PPM, may therefore be not justified in this patient subgroup.
Collapse
Affiliation(s)
- Elena Sportelli
- aDivision of Cardiac Surgery bDivision of Cardiology, IRCCS San Martino-IST, University of Genova Medical School, Genova, Italy
| | | | | | | | | | | | | | | |
Collapse
|
32
|
Puri R, Byrne J, Muller R, Baumbach H, Eltchaninoff H, Redwood S, Cheema A, Dubois C, Ihlberg L, Wijeysundera HC, Cerillo A, Götberg M, Klaaborg KE, Pelletier M, Blanco-Mata R, Edwards R, Gandolfo C, Muir D, Meucci F, Sinning JM, Stella P, Veulemans V, Virtanen M, Regueiro A, Thoenes M, Pibarot P, Pelletier-Beaumont E, Rodés-Cabau J. Transcatheter aortic valve implantation in patients with small aortic annuli using a 20 mm balloon-expanding valve. Heart 2016; 103:148-153. [PMID: 27534978 DOI: 10.1136/heartjnl-2016-309707] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/30/2016] [Revised: 06/09/2016] [Accepted: 07/13/2016] [Indexed: 11/04/2022] Open
Abstract
BACKGROUND While transcatheter aortic valve implantation (TAVI) is established for treating high-operative risk surgical aortic valve replacement candidates, until recently the smallest transcatheter heart valve (THV) measured 23 mm, posing greater risk for annular rupture and THV failure in patients with aortic stenosis (AS) with small aortic annuli (≤20 mm). OBJECTIVES In the setting of a multicentre registry, we report on the safety, efficacy and early clinical outcomes of the SAPIEN XT 20 mm balloon-expanding THV. RESULTS Among TAVI 55 recipients (n=30 for native AS, n=25 for a valve-in-valve procedure (V-in-V)), median age and Society of Thoracic Surgeons score were 85 (81 to 87) years and 7.8 (4.7 to 12.4)%, respectively. Mean and minimum annular diameters were 19±1 and 17±2 mm, respectively, in native patients with AS, and 17±1 mm (internal diameter) in V-in-V recipients. Successful device implantation rate was 96%, with no procedural-related death. Overall in-hospital-30-day death, stroke and major bleeding rates were 5%, 2% and 9%, respectively. In native AS TAVI recipients, mean transaortic gradient decreased from 54±20 to 12±5 mm Hg (p<0.001), and from 45±17 to 24±8 mm Hg (p<0.001) in V-in-V recipients. Severe prosthesis-patient mismatch (PPM) rates were 10% and 48% in native AS and V-in-V TAVI recipients, respectively (p=0.03). Post-TAVI, the rate of moderate aortic regurgitation was 7% and 0% in native AS and V-in-V TAVI recipients, respectively. CONCLUSIONS TAVI with the 20 mm SAPIEN XT THV appears safe and technically feasible, with acceptable short-term clinical outcomes and low rates of severe PPM in those with native AS.
Collapse
Affiliation(s)
- Rishi Puri
- Quebec Heart & Lung Institute, Laval University, Quebec City, Quebec, Canada
| | | | | | | | | | | | - Asim Cheema
- St. Michael's Hospital, Toronto, Ontario, Canada
| | - Christophe Dubois
- Universitaire Ziekenhuizen and Katholieke Universiteit Leuven, Leuven, Belgium
| | - Leo Ihlberg
- Helsinki University Hospital, Helsinki, Finland
| | | | | | | | | | - Marc Pelletier
- New Brunswick Heart Centre, Saint John, New Brunswick, Canada
| | | | | | | | - Douglas Muir
- The James Cook University Hospital, Middlesbrough, UK
| | - Francesco Meucci
- Azienda Ospedaliero Universitaria Careggi Largo Brambilla, Florence, Italy
| | | | - Pieter Stella
- University Medical Center Utrecht, Utrecht, The Netherlands
| | | | | | - Ander Regueiro
- Quebec Heart & Lung Institute, Laval University, Quebec City, Quebec, Canada
| | - Martin Thoenes
- Edwards LifeSciences, Nyon, Switzerland.,Léman Research Institute, Switzerland
| | - Philippe Pibarot
- Quebec Heart & Lung Institute, Laval University, Quebec City, Quebec, Canada
| | | | - Josep Rodés-Cabau
- Quebec Heart & Lung Institute, Laval University, Quebec City, Quebec, Canada
| |
Collapse
|
33
|
Sawaya F, Kappetein AP, Wisser W, Nataf P, Thomas M, Schächinger V, De Bruyne B, Eltchaninoff H, Thielmann M, Himbert D, Romano M, Wimmer-Greinecker G, Serruys P, Lefèvre T. Five-year haemodynamic outcomes of the first-generation SAPIEN balloon-expandable transcatheter heart valve. EUROINTERVENTION 2016; 12:775-82. [DOI: 10.4244/eijv12i6a126] [Citation(s) in RCA: 21] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
|
34
|
Thyregod HGH, Steinbrüchel DA, Ihlemann N, Ngo TA, Nissen H, Kjeldsen BJ, Chang Y, Hansen PB, Olsen PS, Søndergaard L. No clinical effect of prosthesis-patient mismatch after transcatheter versus surgical aortic valve replacement in intermediate- and low-risk patients with severe aortic valve stenosis at mid-term follow-up: an analysis from the NOTION trial. Eur J Cardiothorac Surg 2016; 50:721-728. [PMID: 27005980 DOI: 10.1093/ejcts/ezw095] [Citation(s) in RCA: 48] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/10/2015] [Revised: 02/15/2016] [Accepted: 02/22/2016] [Indexed: 02/06/2023] Open
Abstract
OBJECTIVES Prosthesis-patient mismatch (PPM) after surgical aortic valve replacement (SAVR) for severe aortic valve stenosis (AVS) is common, but less common after transcatheter aortic valve replacement (TAVR) in patients considered at high risk for death after surgery. The objectives of this study were to determine incidence and clinical effect of PPM after SAVR and TAVR in a primarily low-risk patient group. METHODS Patients 70 years or older with severe isolated AVS, regardless of predicted operative mortality risk, were consecutively randomized 1:1 to TAVR using a self-expandable bioprosthesis (n = 145) or SAVR (n = 135). Post-procedure PPM was graded after 3 months as follows: Not present-mild, if indexed effective orifice area (iEOA) >0.85 cm2/m2, moderate, if 0.65 cm2/m2 < iEOA ≤ 0.85 cm2/m2 and severe, if iEOA ≤0.65 cm2/m2. Outcomes were major adverse cardiac and cerebrovascular events (MACCE, e.g. composite rate of all-cause death, stroke, myocardial infarction or valve reintervention), cardiac-related hospitalizations and New York Heart Association (NYHA) functional class after 2 years. RESULTS The incidence and the severity of PPM were significantly lower after TAVR compared with SAVR (severe, moderate, none-mild 14.0, 35.5, 50.4 vs 33.9, 36.7, 29.4%; P<0.001). PPM resulted in similar higher mean valve gradients at 3 months for both groups. Baseline characteristics related to severe PPM were younger age, absence of diabetes mellitus, lower mortality-risk score for TAVR, and younger age and higher body mass index for SAVR. At 2 years, there were numerical but no statistically significant differences between both TAVR and SAVR patients with severe and no severe PPM for MACCE (0.0 vs 12.8% for TAVR; P = 0.13, and 13.5 vs 7.0% for SAVR; P = 0.27), number of cardiac-related hospitalizations (mean ± standard deviation 0.4 ± 0.6 vs 0.6 ± 0.8; P = 0.23, and 0.4 ± 0.8 vs 0.5 ± 0.9; P = 0.70) and NYHA functional class (Class I/II/III/IV: 64.7/29.4/5.9/0.0 vs 62.1/34.7/3.2/0.0%, respectively; P = 0.91, and 71.4/25.7/2.9/0.0 vs 72.9/22.9/4.3/0.0%, respectively; P = 0.92). CONCLUSIONS The incidence of PPM was lower and less severe after TAVR compared with SAVR in intermediate- and low-risk patients with severe AVS. There were no significant differences in MACCE, cardiac-related hospitalizations or NYHA class after 2 years for patients with versus those without severe PPM.
Collapse
Affiliation(s)
- Hans Gustav Hørsted Thyregod
- Department of Cardiothoracic Surgery, The Heart Centre, Rigshospitalet, Copenhagen University Hospital, Copenhagen, Denmark
| | - Daniel Andreas Steinbrüchel
- Department of Cardiothoracic Surgery, The Heart Centre, Rigshospitalet, Copenhagen University Hospital, Copenhagen, Denmark
| | - Nikolaj Ihlemann
- Department of Cardiology, The Heart Centre, Rigshospitalet, Copenhagen University Hospital, Copenhagen, Denmark
| | - Thuc Anh Ngo
- Department of Cardiology, The Heart Centre, Rigshospitalet, Copenhagen University Hospital, Copenhagen, Denmark
| | - Henrik Nissen
- Department of Cardiology, Odense University Hospital, Odense, Denmark
| | - Bo Juel Kjeldsen
- Department of Cardiothoracic and Vascular Surgery, Odense University Hospital, Odense, Denmark
| | | | - Peter Bo Hansen
- Department of Cardiac Anesthesia, The Heart Centre, Rigshospitalet, Copenhagen University Hospital, Copenhagen, Denmark
| | - Peter Skov Olsen
- Department of Cardiothoracic Surgery, The Heart Centre, Rigshospitalet, Copenhagen University Hospital, Copenhagen, Denmark
| | - Lars Søndergaard
- Department of Cardiology, The Heart Centre, Rigshospitalet, Copenhagen University Hospital, Copenhagen, Denmark
| |
Collapse
|
35
|
Cho IJ, Hong GR, Lee SH, Lee S, Chang BC, Shim CY, Chang HJ, Ha JW, Chung N. Prosthesis-Patient Mismatch after Mitral Valve Replacement: Comparison of Different Methods of Effective Orifice Area Calculation. Yonsei Med J 2016; 57:328-36. [PMID: 26847283 PMCID: PMC4740523 DOI: 10.3349/ymj.2016.57.2.328] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/23/2015] [Revised: 05/13/2015] [Accepted: 06/19/2015] [Indexed: 01/20/2023] Open
Abstract
PURPOSE The incidence of prosthesis-patient mismatch (PPM) after mitral valve replacement (MVR) has been reported to vary. The purpose of the current study was to investigate incidence of PPM according to the different methods of calculating effective orifice area (EOA), including the continuity equation (CE), pressure half time (PHT) method and use of reference EOA, and to compare these with various echocardiographic variables. MATERIALS AND METHODS We retrospectively reviewed 166 individuals who received isolated MVR due to rheumatic mitral stenosis and had postoperative echocardiography performed between 12 and 60 months after MVR. EOA was determined by CE (EOA(CE)) and PHT using Doppler echocardiography. Reference EOA was determined from the literature or values offered by the manufacturer. Indexed EOA was used to define PPM as present if ≤1.2 cm²/m². RESULTS Prevalence of PPM was different depending on the methods used to calculate EOA, ranging from 7% in PHT method to 49% in referred EOA method to 62% in CE methods. The intraclass correlation coefficient was low between the methods. PPM was associated with raised trans-prosthetic pressure, only when calculated by CE (p=0.021). Indexed EOA(CE) was the only predictor of postoperative systolic pulmonary artery (PA) pressure, even after adjusting for age, preoperative systolic PA pressure and postoperative left atrial volume index (p<0.001). CONCLUSION Prevalence of mitral PPM varied according to the methods used to calculate EOA in patients with mitral stenosis after MVR. Among the various methods used to define PPM, EOA(CE) was the only predictor of postoperative hemodynamic parameters.
Collapse
Affiliation(s)
- In Jeong Cho
- Division of Cardiology, Severance Cardiovascular Hospital, Yonsei University College of Medicine, Seoul, Korea
| | - Geu Ru Hong
- Division of Cardiology, Severance Cardiovascular Hospital, Yonsei University College of Medicine, Seoul, Korea.
| | - Seung Hyun Lee
- Division of Cardiovascular Surgery, Severance Cardiovascular Hospital, Yonsei University College of Medicine, Seoul, Korea
| | - Sak Lee
- Division of Cardiovascular Surgery, Severance Cardiovascular Hospital, Yonsei University College of Medicine, Seoul, Korea
| | - Byung Chul Chang
- Division of Cardiovascular Surgery, Severance Cardiovascular Hospital, Yonsei University College of Medicine, Seoul, Korea
| | - Chi Young Shim
- Division of Cardiology, Severance Cardiovascular Hospital, Yonsei University College of Medicine, Seoul, Korea
| | - Hyuk Jae Chang
- Division of Cardiology, Severance Cardiovascular Hospital, Yonsei University College of Medicine, Seoul, Korea
| | - Jong Won Ha
- Division of Cardiology, Severance Cardiovascular Hospital, Yonsei University College of Medicine, Seoul, Korea
| | - Namsik Chung
- Division of Cardiology, Severance Cardiovascular Hospital, Yonsei University College of Medicine, Seoul, Korea
| |
Collapse
|
36
|
Poulin F, Yingchoncharoen T, Wilson WM, Horlick EM, Généreux P, Tuzcu EM, Stewart W, Osten MD, Woo A, Thavendiranathan P. Impact of Prosthesis-Patient Mismatch on Left Ventricular Myocardial Mechanics After Transcatheter Aortic Valve Replacement. J Am Heart Assoc 2016; 5:JAHA.115.002866. [PMID: 26857069 PMCID: PMC4802434 DOI: 10.1161/jaha.115.002866] [Citation(s) in RCA: 26] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/07/2023]
Abstract
Background The aim of this study was to compare left ventricular (LV) remodeling using myocardial strain between patients with severe aortic stenosis (AS) treated with transcatheter aortic valve replacement (TAVR) with and without prosthesis‐patient mismatch (PPM). Methods and Results In a retrospective study, speckle‐tracking echocardiography was used to measure global longitudinal strain (GLS) and strain rate (GLSR), circumferential strain, and rotation before and at mid‐term follow‐up post‐TAVR. Moderate and severe PPM were defined as an effective orifice area ≤0.85 and <0.65 cm2/m2, respectively. A total of 102 patients (median age, 83 years [77–88]) with severe AS were included. At 6±3 months post‐TAVR, moderate and severe PPM were found in 32 (31%) and 9 (9%) patients. Patients without PPM had a significant regression in LV mass (from 134±41 to 119±38 g/m2; P=0.001) at follow‐up whereas those with PPM did not. There was a significant improvement in LV GLS (−12.8±4.0 to −14.3±4.3%; P=0.01), GLSR (−0.61±0.20 to −0.73±0.25 second−1; P<0.001), and early diastolic strain rate (0.52±0.20 to 0.64±0.20 second−1; P<0.001) in patients without PPM, but not in those with PPM. After adjustment for pre‐TAVR ejection fraction and post‐TAVR aortic regurgitation, patients without PPM had greater improvement in LV longitudinal strain parameters compared to those with PPM. After a median follow‐up of 46.1 months (interquartile range, 35.4–60.8), there was no difference in survival between patients with and without PPM. Conclusions TAVR was associated with an incidence of PPM of 40%. Greater reverse LV remodeling using myocardial strain was evident in patients without PPM compared to PPM. Presence of PPM was not associated with mortality.
Collapse
Affiliation(s)
- Frédéric Poulin
- Peter Munk Cardiac Center, Toronto General Hospital, University of Toronto Toronto Ontario, Canada Research Center, Hôpital du Sacré-Coeur de Montréal, University of Montreal Montreal Quebec, Canada
| | | | - William M Wilson
- Peter Munk Cardiac Center, Toronto General Hospital, University of Toronto Toronto Ontario, Canada
| | - Eric M Horlick
- Peter Munk Cardiac Center, Toronto General Hospital, University of Toronto Toronto Ontario, Canada
| | - Philippe Généreux
- Research Center, Hôpital du Sacré-Coeur de Montréal, University of Montreal Montreal Quebec, Canada
| | | | | | - Mark D Osten
- Peter Munk Cardiac Center, Toronto General Hospital, University of Toronto Toronto Ontario, Canada
| | - Anna Woo
- Peter Munk Cardiac Center, Toronto General Hospital, University of Toronto Toronto Ontario, Canada
| | | |
Collapse
|
37
|
Mini-aortic valve replacements are not associated with an increased incidence of patient–prosthesis mismatch: a propensity-scored analysis. Gen Thorac Cardiovasc Surg 2015; 64:144-8. [DOI: 10.1007/s11748-015-0614-z] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/02/2015] [Accepted: 12/04/2015] [Indexed: 11/26/2022]
|
38
|
Cao H, Qiu Z, Chen L, Chen D, Chen Q. Star GK Bileaflet Mechanical Valve Prosthesis-Patient Mismatch after Mitral Valve Replacement: A Chinese Multicenter Clinical Study. Med Sci Monit 2015; 21:2542-6. [PMID: 26313311 PMCID: PMC4556164 DOI: 10.12659/msm.894044] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/09/2022] Open
Abstract
BACKGROUND The aim of this study was to investigate the incidence and immediate and mid-term effects of heart valve prosthesis-patient mismatch (PPM) after mitral valve replacement using the GK bileaflet mechanical valve. MATERIAL AND METHODS A total of 493 cases of mechanical mitral valve replacement were performed in the departments of cardiac surgery in 7 hospitals from January 2000 to January 2008. The patients included 142 men and 351 women ages 21 to 67 (average age, 48.75). The patients were followed for 3 years after surgery. The effective orifice area index (EOAI), ≤1.2 cm2/m2, was detected during the follow-up period and was defined as PPM. The patients were assigned to either the PPM group or the non-PPM group. Finally, the preoperative, perioperative and postoperative indexes of the 2 groups of patients were compared. RESULTS A total of 157 patients had PPM 3 years after surgery. The incidence of PPM was 31.84%. Sixty-three patients in the PPM group received a 25-mm GK bileaflet valve (40.13%), 82 received a 27-mm valve (52.23%), and 12 (7.64%) received a 29-mm valve. There were significant differences in length of intensive care unit stay, duration of ventilator use, length of hospitalization, body surface area, EOAI, mean transmitral pressure gradient, and pulmonary artery pressure between the PPM and non-PPM group (P<0.05). There was a significant difference between preoperative and postoperative pulmonary artery pressures among non-PPM patients (P<0.05); however, there was no statistical difference in preoperative and postoperative pulmonary artery pressures among patients with PPM (P>0.05). CONCLUSIONS PPM after mitral valve replacement influences postoperative hemodynamics. Thus, larger-sized GK bileaflet mechanical valves are often used to reduce the risk of PPM.
Collapse
Affiliation(s)
- Hua Cao
- Department of Cardiac Surgery, Union Hospital, Fujian Medical University, Fuzhou, Fujian, China (mainland)
| | - Zhihuang Qiu
- Department of Cardiac Surgery, Union Hospital, Fujian Medical University, Fuzhou, Fujian, China (mainland)
| | - Liangwan Chen
- Department of Cardiac Surgery, Union Hospital, Fujian Medical University, Fuzhou, Fujian, China (mainland)
| | - Daozhong Chen
- Department of Cardiac Surgery, Union Hospital, Fujian Medical University, Fuzhou, Fujian, China (mainland)
| | - Qiang Chen
- Department of Cardiac Surgery, Union Hospital, Fujian Medical University, Fuzhou, Fujian, China (mainland)
| |
Collapse
|
39
|
Laflamme J, Puri R, Urena M, Laflamme L, DeLarochellière H, Abdul-Jawad Altisent O, del Trigo M, Campelo-Parada F, DeLarochellière R, Paradis JM, Dumont E, Doyle D, Mohammadi S, Côté M, Pibarot P, Laroche V, Rodés-Cabau J. Incidence and risk factors of hemolysis after transcatheter aortic valve implantation with a balloon-expandable valve. Am J Cardiol 2015; 115:1574-9. [PMID: 25862156 DOI: 10.1016/j.amjcard.2015.02.059] [Citation(s) in RCA: 21] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/13/2015] [Revised: 02/26/2015] [Accepted: 02/26/2015] [Indexed: 10/23/2022]
Abstract
There are currently no data evaluating the hematologic and biocompatibility profile of transcatheter aortic valves in vivo. We evaluated the incidence, predictive factors, and clinical consequences associated with hemolysis post-transcatheter aortic valve implantation (TAVI). A total of 122 patients who underwent TAVI with a balloon-expandable valve were included. Baseline blood sampling and echocardiography, followed by early post-TAVI echocardiography and repeat blood sampling, at 6 to 12 months post-TAVI were performed. Hemolysis post-TAVI was defined according to the established criteria. The incidence of hemolysis post-TAVI was 14.8% yet no patient experienced severe hemolytic anemia requiring transfusion. Compared with the nonhemolysis group, those with hemolysis demonstrated significant reductions in hemoglobin (p = 0.012), were more frequently women (67% vs 34%, p = 0.016), and had a higher incidence of post-TAVI severe prosthesis-patient mismatch (PPM) (44% vs 17%, p = 0.026). The rate of mild or more prosthetic valve regurgitation did not significantly differ between those patients with and without hemolysis (56% vs 37%, p = 0.44). Wall shear rate (WSR) and energy loss index (ELI), both indirect measures of shear stress, were higher (p = 0.039) and lower (p = 0.004), respectively, in those patients with hemolysis. Increasing PPM severity was also associated with significant stepwise WSR increments and ELI decrements (p <0.01 for both). In conclusion, subclinical hemolysis occurred in 15% of patients following TAVI. Although prosthetic valve regurgitation had no impact on hemolysis, a novel association between PPM and hemolysis was found, likely driven by higher shear stress as determined by WSR and ELI. These hematologic and biomechanical findings may have long-term clinical implications and could affect future transcatheter aortic valve design.
Collapse
|
40
|
Arnáiz-García ME, González-Santos JM, Arévalo-Abascal A, Bueno-Codoñer M, Dalmau-Sorlí MJ, López-Rodríquez J, Arribas-Jiménez A. [Subvalvular pannus as cause of late mismatch after aortic valve replacement]. ARCHIVOS DE CARDIOLOGIA DE MEXICO 2015; 85:168-9. [PMID: 25577550 DOI: 10.1016/j.acmx.2014.09.006] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/22/2014] [Revised: 09/09/2014] [Accepted: 09/15/2014] [Indexed: 10/24/2022] Open
Affiliation(s)
| | | | - Adolfo Arévalo-Abascal
- Servicio de Cirugía Cardiaca, Hospital Clínico Universitario de Salamanca, Salamanca, España
| | - María Bueno-Codoñer
- Servicio de Cirugía Cardiaca, Hospital Clínico Universitario de Salamanca, Salamanca, España
| | - María José Dalmau-Sorlí
- Servicio de Cirugía Cardiaca, Hospital Clínico Universitario de Salamanca, Salamanca, España
| | - Javier López-Rodríquez
- Servicio de Cirugía Cardiaca, Hospital Clínico Universitario de Salamanca, Salamanca, España
| | | |
Collapse
|
41
|
Pibarot P, Weissman NJ, Stewart WJ, Hahn RT, Lindman BR, McAndrew T, Kodali SK, Mack MJ, Thourani VH, Miller DC, Svensson LG, Herrmann HC, Smith CR, Rodés-Cabau J, Webb J, Lim S, Xu K, Hueter I, Douglas PS, Leon MB. Incidence and sequelae of prosthesis-patient mismatch in transcatheter versus surgical valve replacement in high-risk patients with severe aortic stenosis: a PARTNER trial cohort--a analysis. J Am Coll Cardiol 2014; 64:1323-34. [PMID: 25257633 DOI: 10.1016/j.jacc.2014.06.1195] [Citation(s) in RCA: 333] [Impact Index Per Article: 30.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/06/2014] [Revised: 06/03/2014] [Accepted: 06/08/2014] [Indexed: 10/24/2022]
Abstract
BACKGROUND Little is known about the incidence of prosthesis-patient mismatch (PPM) and its impact on outcomes after transcatheter aortic valve replacement (TAVR). OBJECTIVES The objectives of this study were: 1) to compare the incidence of PPM in the TAVR and surgical aortic valve replacement (SAVR) randomized control trial (RCT) arms of the PARTNER (Placement of AoRTic TraNscathetER Valves) I Trial cohort A; and 2) to assess the impact of PPM on regression of left ventricular (LV) hypertrophy and mortality in these 2 arms and in the TAVR nonrandomized continued access (NRCA) registry cohort. METHODS The PARTNER Trial cohort A randomized patients 1:1 to TAVR or bioprosthetic SAVR. Postoperative PPM was defined as absent if the indexed effective orifice area (EOA) was >0.85 cm(2)/m(2), moderate if the indexed EOA was ≥0.65 but ≤0.85 cm(2)/m(2), or severe if the indexed EOA was <0.65 cm(2)/m(2). LV mass regression and mortality were analyzed using the SAVR-RCT (n = 270), TAVR-RCT (n = 304), and TAVR-NRCA (n = 1,637) cohorts. RESULTS The incidence of PPM was 60.0% (severe: 28.1%) in the SAVR-RCT cohort versus 46.4% (severe: 19.7%) in the TAVR-RCT cohort (p < 0.001) and 43.8% (severe: 13.6%) in the TAVR-NRCA cohort. In patients with an aortic annulus diameter <20 mm, severe PPM developed in 33.7% undergoing SAVR compared with 19.0% undergoing TAVR (p = 0.002). PPM was an independent predictor of less LV mass regression at 1 year in the SAVR-RCT (p = 0.017) and TAVR-NRCA (p = 0.012) cohorts but not in the TAVR-RCT cohort (p = 0.35). Severe PPM was an independent predictor of 2-year mortality in the SAVR-RCT cohort (hazard ratio [HR]: 1.78; p = 0.041) but not in the TAVR-RCT cohort (HR: 0.58; p = 0.11). In the TAVR-NRCA cohort, severe PPM was not a predictor of 1-year mortality in all patients (HR: 1.05; p = 0.60) but did independently predict mortality in the subset of patients with no post-procedural aortic regurgitation (HR: 1.88; p = 0.02). CONCLUSIONS In patients with severe aortic stenosis and high surgical risk, PPM is more frequent and more often severe after SAVR than TAVR. Patients with PPM after SAVR have worse survival and less LV mass regression than those without PPM. Severe PPM also has a significant impact on survival after TAVR in the subset of patients with no post-procedural aortic regurgitation. TAVR may be preferable to SAVR in patients with a small aortic annulus who are susceptible to PPM to avoid its adverse impact on LV mass regression and survival. (The PARTNER Trial: Placement of AoRTic TraNscathetER Valve Trial; NCT00530894).
Collapse
Affiliation(s)
- Philippe Pibarot
- Québec Heart and Lung Institute/Institut Universitaire de Cardiologie et de Pneumologie de Québec, Laval University, Québec, Canada.
| | | | - William J Stewart
- Department of Cardiovascular Medicine, Cleveland Clinic, Cleveland, Ohio
| | - Rebecca T Hahn
- Columbia University Medical Center/New York-Presbyterian Hospital, New York, New York; The Cardiovascular Research Foundation, New York, New York
| | - Brian R Lindman
- Washington University School of Medicine, St. Louis, Missouri
| | | | - Susheel K Kodali
- Columbia University Medical Center/New York-Presbyterian Hospital, New York, New York; The Cardiovascular Research Foundation, New York, New York
| | | | | | - D Craig Miller
- Stanford University School of Medicine, Stanford, California
| | - Lars G Svensson
- Department of Thoracic and Cardiovascular Surgery, Cleveland Clinic, Cleveland, Ohio
| | - Howard C Herrmann
- Hospital of the University of Pennsylvania, Philadelphia, Pennsylvania
| | - Craig R Smith
- Columbia University Medical Center/New York-Presbyterian Hospital, New York, New York; The Cardiovascular Research Foundation, New York, New York
| | - Josep Rodés-Cabau
- Québec Heart and Lung Institute/Institut Universitaire de Cardiologie et de Pneumologie de Québec, Laval University, Québec, Canada
| | - John Webb
- University of British Columbia and St. Paul's Hospital, Vancouver, Canada
| | - Scott Lim
- University of Virginia Medical Center, Charlottesville, Virginia
| | - Ke Xu
- The Cardiovascular Research Foundation, New York, New York
| | - Irene Hueter
- Columbia University Medical Center/New York-Presbyterian Hospital, New York, New York
| | - Pamela S Douglas
- Duke University Medical Center and Duke Clinical Research Institute, Durham, North Carolina
| | - Martin B Leon
- Columbia University Medical Center/New York-Presbyterian Hospital, New York, New York; The Cardiovascular Research Foundation, New York, New York
| |
Collapse
|
42
|
Laflamme MH, Mahjoub H, Mahmut A, Boulanger MC, Larose E, Pibarot P, Mathieu P. Parathyroid hormone is associated with the LV mass after aortic valve replacement. Heart 2014; 100:1859-64. [PMID: 25095827 DOI: 10.1136/heartjnl-2014-305837] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/04/2022] Open
Abstract
AIMS LV hypertrophy (LVH) is frequent after aortic valve replacement (AVR) and is often associated with comorbidities, including hypertension, obesity, renal failure and prosthesis-patient mismatch (PPM). However, whether other biological mechanism(s) may participate to LVH after AVR is still unknown. Parathyroid hormone (PTH) may play a role in LVH. However, it is presently unknown whether PTH is associated with LVH in patients that have undergone an AVR. METHODS In this cross-sectional study, 195 patients have been investigated at a mean of 8 ± 3.5 years following AVR. LV function and mass were evaluated by Doppler echocardiography. The plasma levels of PTH, 25-hydroxyvitamin D (25-OHD), calcium and phosphate were measured. RESULTS There were 102 (52%) patients with LVH after AVR. In univariate analyses, PTH blood level was associated with LV mass (LVMi) and LVH. After adjustment for other risk factors, elevated PTH remained associated with LVMi (p=0.003) and LVH (p=0.02). In turn, the blood levels of 25-OHD and the renal function (GFR) were independently and inversely related to the blood level of PTH. CONCLUSIONS After AVR, the level of PTH is independently associated with LVH. In turn, the level of PTH is related with the renal function and the level of 25-OHD.
Collapse
Affiliation(s)
- Marie-Hélène Laflamme
- Laboratoire d'Études Moléculaires des Valvulopathies (LEMV), Department of Surgery, Groupe de Recherche en Valvulopathies (GRV), Quebec Heart and Lung Institute/Research Center, Laval University, Quebec, Canada
| | - Haifa Mahjoub
- Institut universitaire de cardiologie et de pneumologie de Québec, Québec, Canada
| | - Ablajan Mahmut
- Laboratoire d'Études Moléculaires des Valvulopathies (LEMV), Department of Surgery, Groupe de Recherche en Valvulopathies (GRV), Quebec Heart and Lung Institute/Research Center, Laval University, Quebec, Canada
| | - Marie-Chloé Boulanger
- Laboratoire d'Études Moléculaires des Valvulopathies (LEMV), Department of Surgery, Groupe de Recherche en Valvulopathies (GRV), Quebec Heart and Lung Institute/Research Center, Laval University, Quebec, Canada
| | - Eric Larose
- Institut universitaire de cardiologie et de pneumologie de Québec, Québec, Canada
| | - Philippe Pibarot
- Institut universitaire de cardiologie et de pneumologie de Québec, Québec, Canada
| | - Patrick Mathieu
- Laboratoire d'Études Moléculaires des Valvulopathies (LEMV), Department of Surgery, Groupe de Recherche en Valvulopathies (GRV), Quebec Heart and Lung Institute/Research Center, Laval University, Quebec, Canada
| |
Collapse
|
43
|
Dumesnil JG, Pibarot P. The Problem of Severe Valve Prosthesis-Patient Mismatch in Aortic Bioprostheses: Near Extinction? J Am Soc Echocardiogr 2014; 27:598-600. [DOI: 10.1016/j.echo.2014.04.005] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 10/25/2022]
|
44
|
Grau JB, Mak AW, Ferrari G, Johnson CK, Shaw RE, Sperling J, Brizzio ME, Zapolanski A. Perioperative predictors of midterm survival after aortic valve replacement. Asian Cardiovasc Thorac Ann 2014; 22:566-73. [PMID: 24867031 DOI: 10.1177/0218492313501509] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
BACKGROUND Elderly patients with aortic stenosis are under-referred for aortic valve replacement surgery. This study investigated the perioperative factors associated with midterm outcomes in a consecutive series of patients undergoing aortic valve replacement with or without coronary artery bypass graft surgery. METHODS From 2006 to 2010, 509 patients having aortic valve replacement or aortic valve replacement with coronary artery bypass were grouped according to age (<80 years and ≥80 years) and procedure (aortic valve replacement ± coronary artery bypass). Patient survival was followed up for 5 years (mean 2.6 years). Midterm survival was evaluated using Kaplan-Meier and Cox proportional hazards regression model statistics. RESULTS AND CONCLUSIONS 5-year survival among octogenarians was 59.2% with an observed 30-day mortality of 1% for aortic valve replacement and 3% for aortic valve replacement with coronary artery bypass. Kaplan-Meier survival analysis showed that age ≥80 years, New York Heart Association functional class III/IV, and left ventricular ejection fraction <35% were significantly associated with increased midterm mortality. Cox regression modeling demonstrated that age ≥80 years was the only significant independent factor associated with midterm mortality; older patients had a 3-fold increase in mortality (adjusted hazard ratio = 3.231, 95% confidence interval: 1.764-5.920, p < 0.0001). While hospital and 30-day mortality were not statistically different between age groups, age ≥80 years was the most powerful predictor of midterm death. These results support early aortic valve replacement with or without coronary artery bypass in aortic stenosis management.
Collapse
Affiliation(s)
- Juan B Grau
- The Valley Columbia Heart Center, Columbia University College of Physicians and Surgeons, Ridgewood NJ, USA University of Pennsylvania School of Medicine, Glenolden, PA, USA
| | - Andrew Wc Mak
- The Valley Columbia Heart Center, Columbia University College of Physicians and Surgeons, Ridgewood NJ, USA
| | - Giovanni Ferrari
- The Valley Columbia Heart Center, Columbia University College of Physicians and Surgeons, Ridgewood NJ, USA University of Pennsylvania School of Medicine, Glenolden, PA, USA
| | - Christopher K Johnson
- The Valley Columbia Heart Center, Columbia University College of Physicians and Surgeons, Ridgewood NJ, USA
| | - Richard E Shaw
- The Valley Columbia Heart Center, Columbia University College of Physicians and Surgeons, Ridgewood NJ, USA
| | - Jason Sperling
- The Valley Columbia Heart Center, Columbia University College of Physicians and Surgeons, Ridgewood NJ, USA
| | - Mariano E Brizzio
- The Valley Columbia Heart Center, Columbia University College of Physicians and Surgeons, Ridgewood NJ, USA
| | - Alex Zapolanski
- The Valley Columbia Heart Center, Columbia University College of Physicians and Surgeons, Ridgewood NJ, USA
| |
Collapse
|
45
|
Abstract
BACKGROUND Patient-prosthesis mismatch is a known and severe complication after aortic valve repair in the general population. There is a paucity of literature regarding this condition in pregnancy. CASE We present the clinical course of a pregnant woman with severe patient-prosthesis mismatch after aortic valve replacement. After extensive workup, the patient underwent aortic valve replacement, enlargement of the aortic root, and placement of a larger prosthetic valve at 21 weeks of gestation. Her postoperative course was complicated by fetal death. CONCLUSION Cardiopulmonary bypass and aortic valve replacement present a multitude of risks to maternal and fetal health. The obstetrician managing pregnant women with prosthetic heart valves should be aware of the complications that may arise, including patient-prosthesis mismatch.
Collapse
|
46
|
Vernick WJ. Con: patient-prosthesis mismatch now is not an important consideration in the majority of patients after aortic valve replacement. J Cardiothorac Vasc Anesth 2013; 28:184-188. [PMID: 24183317 DOI: 10.1053/j.jvca.2013.06.018] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/28/2013] [Indexed: 11/11/2022]
Affiliation(s)
- William J Vernick
- Department of Anesthesia and Critical Care, Hospital of the University of Pennsylvania, Philadelphia, PA.
| |
Collapse
|
47
|
Tully PJ, Aty W, Rice GD, Bennetts JS, Knight JL, Baker RA. Aortic Valve Prosthesis–Patient Mismatch and Long-Term Outcomes: 19-Year Single-Center Experience. Ann Thorac Surg 2013; 96:844-50. [DOI: 10.1016/j.athoracsur.2013.04.075] [Citation(s) in RCA: 39] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/16/2012] [Revised: 04/17/2013] [Accepted: 04/23/2013] [Indexed: 12/01/2022]
|
48
|
Finkelstein A, Schwartz AL, Uretzky G, Banai S, Keren G, Kramer A, Topilsky Y. Hemodynamic performance and outcome of percutaneous versus surgical stentless bioprostheses for aortic stenosis with anticipated patient-prosthesis mismatch. J Thorac Cardiovasc Surg 2013; 147:1892-9. [PMID: 23993320 DOI: 10.1016/j.jtcvs.2013.07.008] [Citation(s) in RCA: 16] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/26/2013] [Revised: 06/19/2013] [Accepted: 07/09/2013] [Indexed: 11/26/2022]
Abstract
OBJECTIVES We aimed to compare the performance and midterm survival of transcutaneous aortic valve replacement (TAVR) and surgically implanted stentless aortic valve replacement (SAVR) for severe aortic stenosis in patients anticipated to have patient-prosthesis mismatch (PPM). METHODS A retrospective analysis was performed of 86 and 49 consecutive TAVR and SAVR patients with severe aortic stenosis and calculated minimal effective orifice area larger than the best projected effective orifice area. Cox hazard analyses were used to assess the effect of TAVR versus SAVR on outcome. RESULTS The peak and mean transprosthetic gradient at discharge were lower (P < .001 for both) in the TAVR group. Mild or greater aortic regurgitation was more frequent in the TAVR group (61% vs 7%; P < .0001). At 3 months of follow-up, the mean gradient in the TAVR group was similar to that of the SAVR group but the prevalence of aortic regurgitation was still higher. The unadjusted 3-year survival rate was superior in the SAVR versus TAVR group (91.6% ± 4% vs 67.0% ± 7%; P = .01). Adjustments for both age and comorbidity resulted in loss of the difference in mortality between the 2 groups. CONCLUSIONS In patients with anticipated PPM, TAVR offers an immediate lower incidence of PPM than SAVR but a greater prevalence of aortic regurgitation. The differences in transaortic gradients became nonsignificant 3 months postoperatively. The question of whether TAVR is a suitable substitute for SAVR in patients with anticipated PPM, in particular, those who are older and sicker, warrants additional investigation.
Collapse
Affiliation(s)
- Arie Finkelstein
- Division of Cardiovascular Diseases, Tel Aviv Medical Center, Tel-Aviv, Israel
| | - Arie Lorin Schwartz
- Division of Cardiovascular Diseases, Tel Aviv Medical Center, Tel-Aviv, Israel
| | - Gideon Uretzky
- Division of Cardiovascular Surgery, Tel Aviv Medical Center, Tel-Aviv, Israel
| | - Shmuel Banai
- Division of Cardiovascular Diseases, Tel Aviv Medical Center, Tel-Aviv, Israel
| | - Gad Keren
- Division of Cardiovascular Diseases, Tel Aviv Medical Center, Tel-Aviv, Israel
| | - Amir Kramer
- Division of Cardiovascular Surgery, Tel Aviv Medical Center, Tel-Aviv, Israel
| | - Yan Topilsky
- Division of Cardiovascular Diseases, Tel Aviv Medical Center, Tel-Aviv, Israel.
| |
Collapse
|
49
|
Kukucka M, Pasic M, Dreysse S, Buz S, Drews T, Mladenow A, Habazettl H, Kuppe H, Unbehaun A, Hetzer R. Patient-prosthesis mismatch after transapical aortic valve implantation. Ann Cardiothorac Surg 2013; 1:172-5. [PMID: 23977489 DOI: 10.3978/j.issn.2225-319x.2012.07.05] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/15/2012] [Accepted: 07/09/2012] [Indexed: 11/14/2022]
|
50
|
Kandler K, H. Møller C, Hassager C, S. Olsen P, Lilleør N, Steinbrüchel DA. Patient–Prosthesis Mismatch and Reduction in Left Ventricular Mass After Aortic Valve Replacement. Ann Thorac Surg 2013; 96:66-71. [DOI: 10.1016/j.athoracsur.2013.03.089] [Citation(s) in RCA: 19] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/19/2012] [Revised: 03/25/2013] [Accepted: 03/27/2013] [Indexed: 10/26/2022]
|