1
|
Tan VH, See Tow HX, Fong KY, Wang Y, Yeo C, Ching CK, Lim TW. Remote monitoring of cardiac implantable electronic devices using smart device interface versus radiofrequency-based interface: A systematic review. J Arrhythm 2024; 40:596-604. [PMID: 38939794 PMCID: PMC11199811 DOI: 10.1002/joa3.13054] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/22/2024] [Revised: 04/20/2024] [Accepted: 04/23/2024] [Indexed: 06/29/2024] Open
Abstract
Background Guidelines recommended remote monitoring (RM) in managing patients with Cardiac Implantable Electronic Devices. In recent years, smart device (phone or tablet) monitoring-based RM (SM-RM) was introduced. This study aims to systematically review SM-RM versus bedside monitor RM (BM-RM) using radiofrequency in terms of compliance, connectivity, and episode transmission time. Methods We conducted a systematic review, searching three international databases from inception until July 2023 for studies comparing SM-RM (intervention group) versus BM-RM (control group). Results Two matched studies (21 978 patients) were retrieved (SM-RM arm: 9642 patients, BM-RM arm: 12 336 patients). There is significantly higher compliance among SM-RM patients compared with BM-RM patients in both pacemaker and defibrillator patients. Manyam et al. found that more SM-RM patients than BM-RM patients transmitted at least once (98.1% vs. 94.3%, p < .001), and Tarakji et al. showed that SM-RM patients have higher success rates of scheduled transmissions than traditional BM-RM methods (SM-RM: 94.6%, pacemaker manual: 56.3%, pacemaker wireless: 77.0%, defibrillator wireless: 87.1%). There were higher enrolment rates, completed scheduled and patient-initiated transmissions, shorter episode transmission time, and higher connectivity among SM-RM patients compared to BM-RM patients. Younger patients (aged <75) had more patient-initiated transmissions, and a higher proportion had ≥10 transmissions compared with older patients (aged ≥75) in both SM-RM and BM-RM groups. Conclusion SM-RM is a step in the right direction, with good compliance, connectivity, and shorter episode transmission time, empowering patients to be in control of their health. Further research on cost-effectiveness and long-term clinical outcomes can be carried out.
Collapse
Affiliation(s)
- Vern Hsen Tan
- Department of CardiologyChangi General HospitalSingaporeSingapore
| | - Hui Xin See Tow
- Yong Loo Lin School of MedicineNational University of SingaporeSingaporeSingapore
| | - Khi Yung Fong
- Yong Loo Lin School of MedicineNational University of SingaporeSingaporeSingapore
| | - Yue Wang
- Department of CardiologyChangi General HospitalSingaporeSingapore
| | - Colin Yeo
- Department of CardiologyChangi General HospitalSingaporeSingapore
| | - Chi Keong Ching
- Department of CardiologyNational Heart Centre SingaporeSingaporeSingapore
| | - Toon Wei Lim
- Department of CardiologyNational University Heart Centre SingaporeSingaporeSingapore
| |
Collapse
|
2
|
Kowlgi GN, Vaidya V, Dai MY, Futela P, Mishra R, Hodge DO, Deshmukh AJ, Mulpuru SK, Friedman PA, Cha YM. Trends in the 30-year span of noninfectious cardiovascular implantable electronic device complications in Olmsted County. Heart Rhythm O2 2024; 5:158-167. [PMID: 38560372 PMCID: PMC10980926 DOI: 10.1016/j.hroo.2024.02.001] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 04/04/2024] Open
Abstract
Background Cardiac implantable electronic devices (CIEDs), such as permanent pacemakers, implantable cardioverter-defibrillators, and cardiac resynchronization therapy devices, alleviate morbidity and mortality in various diseases. There is a paucity of real-world data on CIED complications and trends. Objectives We sought to describe trends in noninfectious CIED complications over the past 3 decades in Olmsted County. Methods The Rochester Epidemiology Project is a medical records linkage system comprising records of over 500,000 residents of Olmsted County from 1966 to present. CIED implantations between 1988 and 2018 were determined. Trends in noninfectious complications within 30 days of implantation were analyzed. Results A total of 157 (6.2%) of 2536 patients who received CIED experienced device complications. A total of 2.7% of the implants had major complications requiring intervention. Lead dislodgement was the most common (2.8%), followed by hematoma (1.7%). Complications went up from 1988 to 2005, and then showed a downtrend until 2018, driven by a decline in hematomas in the last decade (P < .01). Those with complications were more likely to have prosthetic valves. Obesity appeared to have a protective effect in a multivariate regression model. The mean Charlson comorbidity index has trended up over the 30 years. Conclusion Our study describes a real-world trend of CIED complications over 3 decades. Lead dislodgements and hematomas were the most common complications. Complications have declined over the last decade due to safer practices and a better understanding of anticoagulant management.
Collapse
Affiliation(s)
| | - Vaibhav Vaidya
- Department of Cardiovascular Medicine, Mayo Clinic, Rochester, Minnesota
| | - Ming-Yan Dai
- Department of Cardiovascular Medicine, Mayo Clinic, Rochester, Minnesota
| | - Pragyat Futela
- Department of Cardiovascular Medicine, Mayo Clinic, Rochester, Minnesota
| | - Rahul Mishra
- Department of Cardiovascular Medicine, Mayo Clinic, Rochester, Minnesota
| | - David O. Hodge
- Department of Quantitative Health Sciences, Mayo Clinic, Jacksonville, Florida
| | | | - Siva K. Mulpuru
- Department of Cardiovascular Medicine, Mayo Clinic, Rochester, Minnesota
| | - Paul A. Friedman
- Department of Cardiovascular Medicine, Mayo Clinic, Rochester, Minnesota
| | - Yong-Mei Cha
- Department of Cardiovascular Medicine, Mayo Clinic, Rochester, Minnesota
| |
Collapse
|
3
|
Zito A, Restivo A, Ciliberti G, Laborante R, Princi G, Romiti GF, Galli M, Rodolico D, Bianchini E, Cappannoli L, D'Oria M, Trani C, Burzotta F, Cesario A, Savarese G, Crea F, D'Amario D. Heart failure management guided by remote multiparameter monitoring: A meta-analysis. Int J Cardiol 2023; 388:131163. [PMID: 37429443 DOI: 10.1016/j.ijcard.2023.131163] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/06/2023] [Revised: 07/01/2023] [Accepted: 07/05/2023] [Indexed: 07/12/2023]
Abstract
BACKGROUND Several implant-based remote monitoring strategies are currently tested to optimize heart failure (HF) management by anticipating clinical decompensation and preventing hospitalization. Among these solutions, the modern implantable cardioverter-defibrillator and cardiac resynchronization therapy devices have been equipped with sensors allowing continuous monitoring of multiple preclinical markers of worsening HF, including factors of autonomic adaptation, patient activity, and intrathoracic impedance. OBJECTIVES We aimed to assess whether implant-based multiparameter remote monitoring strategy for guided HF management improves clinical outcomes when compared to standard clinical care. METHODS A systematic literature research for randomized controlled trials (RCTs) comparing multiparameter-guided HF management versus standard of care was performed on PubMed, Embase, and CENTRAL databases. Incidence rate ratios (IRRs) and associated 95% confidence intervals (CIs) were calculated using the Poisson regression model with random study effects. The primary outcome was a composite of all-cause death and HF hospitalization events, whereas secondary endpoints included the individual components of the primary outcome. RESULTS Our meta-analysis included 6 RCTs, amounting to a total of 4869 patients with an average follow-up time of 18 months. Compared with standard clinical management, the multiparameter-guided strategy reduced the risk of the primary composite outcome (IRR 0.83, 95%CI 0.71-0.99), driven by statistically significant effect on both HF hospitalization events (IRR 0.75, 95%CI 0.61-0.93) and all-cause death (IRR 0.80, 95%CI 0.66-0.96). CONCLUSION Implant-based multiparameter remote monitoring strategy for guided HF management is associated with significant benefit on clinical outcomes compared to standard clinical care, providing a benefit on both hospitalization events and all-cause death.
Collapse
Affiliation(s)
- Andrea Zito
- Department of Cardiovascular and Pulmonary Sciences, Catholic University of the Sacred Heart, Rome, Italy
| | - Attilio Restivo
- Department of Cardiovascular and Pulmonary Sciences, Catholic University of the Sacred Heart, Rome, Italy
| | - Giuseppe Ciliberti
- Department of Cardiovascular and Pulmonary Sciences, Catholic University of the Sacred Heart, Rome, Italy
| | - Renzo Laborante
- Department of Cardiovascular and Pulmonary Sciences, Catholic University of the Sacred Heart, Rome, Italy
| | - Giuseppe Princi
- Department of Cardiovascular and Pulmonary Sciences, Catholic University of the Sacred Heart, Rome, Italy
| | - Giulio Francesco Romiti
- Department of Translational and Precision Medicine, Sapienza - University of Rome, Rome, Italy
| | - Mattia Galli
- Department of Cardiovascular and Pulmonary Sciences, Catholic University of the Sacred Heart, Rome, Italy; Maria Cecilia Hospital, GVM Care & Research, Cotignola, Italy
| | - Daniele Rodolico
- Department of Cardiovascular and Pulmonary Sciences, Catholic University of the Sacred Heart, Rome, Italy
| | - Emiliano Bianchini
- Department of Cardiovascular and Pulmonary Sciences, Catholic University of the Sacred Heart, Rome, Italy
| | - Luigi Cappannoli
- Department of Cardiovascular and Pulmonary Sciences, Catholic University of the Sacred Heart, Rome, Italy
| | - Marika D'Oria
- Open Innovation Unit, Scientific Directorate, Fondazione Policlinico Universitario A. Gemelli IRCCS, Rome, Italy
| | - Carlo Trani
- Department of Cardiovascular and Pulmonary Sciences, Catholic University of the Sacred Heart, Rome, Italy; Department of Cardiovascular Medicine, Fondazione Policlinico Universitario A. Gemelli IRCCS, Rome, Italy
| | - Francesco Burzotta
- Department of Cardiovascular and Pulmonary Sciences, Catholic University of the Sacred Heart, Rome, Italy; Department of Cardiovascular Medicine, Fondazione Policlinico Universitario A. Gemelli IRCCS, Rome, Italy
| | - Alfredo Cesario
- Open Innovation Unit, Scientific Directorate, Fondazione Policlinico Universitario A. Gemelli IRCCS, Rome, Italy; CEO, Gemelli Digital Medicine & Health Srl, Rome, Italy
| | - Gianluigi Savarese
- Division of Cardiology, Department of Medicine, Karolinska Institutet, Stockholm, Sweden
| | - Filippo Crea
- Department of Cardiovascular and Pulmonary Sciences, Catholic University of the Sacred Heart, Rome, Italy; Department of Cardiovascular Medicine, Fondazione Policlinico Universitario A. Gemelli IRCCS, Rome, Italy
| | - Domenico D'Amario
- Department of Cardiovascular Medicine, Fondazione Policlinico Universitario A. Gemelli IRCCS, Rome, Italy; Department of Translational Medicine, University of Eastern Piedmont, Maggiore della Carità Hospital, Novara, Italy.
| |
Collapse
|