Abstract
OBJECTIVES
To evaluate the feasibility and reproducibility of 2D and 3D black-blood sequences in measuring morphology of renal arterial wall.
METHODS
The 2D and 3D imaging sequences used variable-refocusing-flip-angle and constant-low-refocusing-flip-angle turbo spin echo (TSE) readout respectively, with delicately selected black-blood scheme and respiratory motion trigger for free-breathing imaging. Fourteen healthy subjects and three patients with Takayasu arteritis underwent renal artery wall imaging with 3D double inversion recovery (DIR) TSE and 2D Variable Flip Angle-TSE (VFA-TSE) black-blood sequences at 3.0 T. Four healthy subjects were randomly selected for scan-rescan reproducibility experiments. Signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR) and morphology of arterial wall were measured and compared using paired-t-test or Wilcoxon signed-rank test between 2D and 3D sequences. The inter-observer, intra-observer and scan-rescan agreements of above measurements were determined using intraclass correlation coefficient (ICC).
RESULTS
The 2D and 3D imaging sequences showed similar morphological measurements (lumen area, wall area, mean wall thickness and maximum wall thickness) of renal arterial wall (all P > 0.05) and excellent agreement (ICC: 0.853-0.954). Compared to 2D imaging, 3D imaging exhibited significantly lower SNRlumen (P < 0.01) and SNRwall (P = 0.037), similar contrast-to-noise ratio (CNR) (P = 0.285), and higher CNR efficiency (CNReff) (P < 0.01). Both 2D and 3D imaging showed good to excellent inter-observer (ICC: 0.723-0.997), intra-observer (ICC: 0.749-0.996) and scan-rescan (ICC: 0.710-0.992) reproducibility in measuring renal arterial wall morphology, SNR and CNR, respectively.
CONCLUSIONS
Both high-resolution free-breathing 2D VFA-TSE and 3D DIR TSE black-blood sequences are feasible and reproducible in high-resolution renal arterial wall imaging. The 2D imaging has high SNR, whereas 3D imaging has high imaging efficiency.