Fölsch C, Sahm P, Ulloa CAF, Krombach GA, Kampschulte M, Rickert M, Pruss A, Jahnke A. Effect of synthetic bone replacement material of different size on shear stress resistance within impacted native and thermodisinfected cancellous bone: an in vitro femoral impaction bone grafting model. Cell Tissue Bank 2021; 22:651-664. [PMID: 33893901 PMCID: PMC8558171 DOI: 10.1007/s10561-021-09924-w] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/22/2020] [Accepted: 04/03/2021] [Indexed: 11/06/2022]
Abstract
Antibiotic carrier particles of variable size might influence mechanic properties within impacted thermodisinfected and native cancellous bone different. Herafill®G containing calciumsulfate and calciumcarbonate provides high local concentrations of gentamicin being important for revision surgery in infected joint replacements. Native and thermodisinfected cancellous bone derived from 6 to 7 months old piglets was used for in vitro impaction bone grafting and supplemented each with Herafill®G granules of two different sizes. Micromovement of implants related to shear force was measured in 29 specimens distributed in 6 groups. Thermodisinfected cancellous bone revealed a significant higher shear force resistance than native bone with a mean difference of 423.8 mdeg/Nm (p < 0.001) ranging within 95% confidence interval from 181.5 to 666.0 mdeg/Nm. Adding small granules to thermodisinfected bone did not reduce shear force resistance significantly since adding large granules to native bone improved it by 344.0 mdeg/Nm (p < 0.003). Shear force resistance was found higher at the distal region of the implant compared to a proximal point of measurement throughout all specimens. Less impaction impulses were necessary for thermodisinfected bone. Thermodisinfected cancellous bone might achieve a higher degree of impaction compared with native bone resulting in increased resistance against shear force since impaction was found increased distally. Supplementation of thermodisinfected bone with small granules of Herafill®G might be considered for application of local antibiotics. Large granules appeared more beneficial for supplementation of native bone. Heterogeneity of bone graft and technical aspects of the impaction procedure have to be considered regarding the reproducibility of femoral impaction bone grafting.
Collapse
Affiliation(s)
- C Fölsch
- Department of Orthopaedic Surgery, Justus-Liebig-University Medical School, Klinikstrasse 33, 35392, Gießen, Germany.
| | - P Sahm
- Laboratory of Biomechanics, Department of Orthopaedic Surgery, Justus-Liebig-University Medical School, Klinikstrasse 29, 35392, Giessen, Germany
| | - C A Fonseca Ulloa
- Laboratory of Biomechanics, Department of Orthopaedic Surgery, Justus-Liebig-University Medical School, Klinikstrasse 29, 35392, Giessen, Germany
| | - G A Krombach
- Department of Diagnostic and Interventional Radiology, Laboratory for Experimental Radiology, Justus-Liebig-University Medical School, Klinikstrasse 33, 35392, Giessen, Germany
| | - M Kampschulte
- Department of Diagnostic and Interventional Radiology, Laboratory for Experimental Radiology, Justus-Liebig-University Medical School, Klinikstrasse 33, 35392, Giessen, Germany
| | - M Rickert
- Department of Orthopaedic Surgery, Justus-Liebig-University Medical School, Klinikstrasse 33, 35392, Gießen, Germany
| | - A Pruss
- Institute of Transfusion Medicine, University Tissue Bank, Charité University Medical School, Charitéplatz 1, 10117, Berlin, Germany
| | - A Jahnke
- Laboratory of Biomechanics, Department of Orthopaedic Surgery, Justus-Liebig-University Medical School, Klinikstrasse 29, 35392, Giessen, Germany
| |
Collapse
|
2
|
Fölsch C, Bok J, Krombach GA, Rickert M, Ulloa CAF, Ahmed GA, Kampschulte M, Jahnke A. Influence of antibiotic pellets on pore size and shear stress resistance of impacted native and thermodisinfected cancellous bone: An in vitro femoral impaction bone grafting model. J Orthop 2020; 22:414-421. [PMID: 33029046 DOI: 10.1016/j.jor.2020.09.011] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/11/2020] [Accepted: 09/13/2020] [Indexed: 10/23/2022] Open
Abstract
Introduction Morphology and mechanic properties of impacted cancellous bone are affected by carrier substances which provide high local concentrations of antibiotics. Methods Bone chips were taken from the femoral head of 6-7 months old piglets. One half was thermodisinfected and the other remained native. Ten specimens each were mixed with Herafill® antibiotic pellets and a control group of each 10 specimens respectively was examined. The cancellous bone was impacted according to Exeter technique and the implants were cemented. The distribution of the particles and the pores were defined with three dimensional computertomographic scan and shear force resistance was measured until failure. Results Shear force resistance was not measured significantly less for thermodisinfected (2.7 Nm) compared with native bone (3.5 Nm) and addition of antibiotic pellets reduced shear force resistance in both groups since this was significant for the native group. The average pore volume of the native bone specimens appeared significant smaller compared to the thermodisinfected group (p = 0.011) and the pore volume showed a negative correlation with shear force resistance (p = 0.044). Pore volume around the pellets was found significantly increased and it appeared smaller for native bone. The number of pellets located next to the implant showed a negative correlation with shear force resistance (p = 0.034) and the negative correlation increased for pellets below the tip of the shaft model (p = 0.024). Conclusion Adding antibiotic pellets to native and thermodisinfected impacted cancellous bone increased pore volume since the area around the pellets showed increased porosity which correlated with reduced shear force resistance. Computertomographic three dimensional measurement of porosity might predict shear force resistance of impacted cancellous bone and improve impaction of bone grafting intraoperatively.
Collapse
Affiliation(s)
- C Fölsch
- Department of Orthopaedics and Orthopaedic Surgery, University Hospital Giessen and Marburg (UKGM), Justus-Liebig-University, Klinikstrasse 33, 35392 Giessen, Germany.,Laboratory of Biomechanics, Justus-Liebig-University Giessen, Klinikstrasse 29, Germany
| | - J Bok
- Laboratory of Biomechanics, Justus-Liebig-University Giessen, Klinikstrasse 29, Germany
| | - G A Krombach
- Department of Diagnostic and Interventional Radiology, Laboratory for Experimental Radiology, Justus-Liebig-University Giessen, Klinikstrasse 33, 35392, Giessen, Germany
| | - M Rickert
- Department of Orthopaedics and Orthopaedic Surgery, University Hospital Giessen and Marburg (UKGM), Justus-Liebig-University, Klinikstrasse 33, 35392 Giessen, Germany.,Laboratory of Biomechanics, Justus-Liebig-University Giessen, Klinikstrasse 29, Germany
| | - C A Fonseca Ulloa
- Laboratory of Biomechanics, Justus-Liebig-University Giessen, Klinikstrasse 29, Germany
| | - G A Ahmed
- Department of Orthopaedics and Orthopaedic Surgery, University Hospital Giessen and Marburg (UKGM), Justus-Liebig-University, Klinikstrasse 33, 35392 Giessen, Germany.,Laboratory of Biomechanics, Justus-Liebig-University Giessen, Klinikstrasse 29, Germany
| | - M Kampschulte
- Department of Diagnostic and Interventional Radiology, Laboratory for Experimental Radiology, Justus-Liebig-University Giessen, Klinikstrasse 33, 35392, Giessen, Germany
| | - A Jahnke
- Laboratory of Biomechanics, Justus-Liebig-University Giessen, Klinikstrasse 29, Germany
| |
Collapse
|
3
|
Ahmed GA, Ishaque B, Rickert M, Fölsch C. [Allogeneic bone transplantation in hip revision surgery : Indications and potential for reconstruction]. DER ORTHOPADE 2019; 47:52-66. [PMID: 29260246 DOI: 10.1007/s00132-017-3506-3] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/14/2022]
Abstract
The increasing number of people having joint replacements will lead to increasing numbers of revision operations. The transplantation of allogeneic bones might reconstruct bone defects and improve long-term anchorage of the implant. A sufficient primary stability of the implanted construct is necessary to achieve osseous incorporation as well as tight contact between the implanted allogeneic and host bones. Transplantation of bone can contribute to downgrading acetabular defects and so avoid bigger reinforcement implants. An improvement of bone stock due to reconstruction of femoral bony defects might also reduce the size of the stem necessary since the indication might be limited in case of extensive bone defects. According to good longterm results of modular revision stems the Impaction-Bone-Grafting has not yet generally been established.
Collapse
Affiliation(s)
- G A Ahmed
- Klinik und Poliklinik für Orthopädie und Orthopädische Chirurgie, Justus-Liebig-Universität Gießen, Klinikstraße 33, 35392, Gießen, Deutschland.
| | - B Ishaque
- Klinik und Poliklinik für Orthopädie und Orthopädische Chirurgie, Justus-Liebig-Universität Gießen, Klinikstraße 33, 35392, Gießen, Deutschland
| | - M Rickert
- Klinik und Poliklinik für Orthopädie und Orthopädische Chirurgie, Justus-Liebig-Universität Gießen, Klinikstraße 33, 35392, Gießen, Deutschland
| | - C Fölsch
- Klinik und Poliklinik für Orthopädie und Orthopädische Chirurgie, Justus-Liebig-Universität Gießen, Klinikstraße 33, 35392, Gießen, Deutschland
| |
Collapse
|
4
|
[Influence of thermodisinfection on impaction of cancellous bone : An in vitro model of femoral impaction bone grafting]. DER ORTHOPADE 2019; 47:39-51. [PMID: 29238859 DOI: 10.1007/s00132-017-3509-0] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 10/18/2022]
Abstract
BACKGROUND The reconstruction of bony defects during endoprosthesis revision surgery using "impaction bone grafting" leads to the possibility of a longstanding osseous integration to achieve good clinical results. Native allogeneic cancellous bone is often used for the procedure. This study examines the influence of thermodisinfection on the impaction behaviour of cancellous bone of different geometries and on the cement distribution. METHODS The cancellous bone was obtained from the femoral heads of 7‑month old pigs. One half of the head was thermodisinfected while the other remained native. Bone chips with sizes of 3-5, 5-8 and 8-10 mm were produced. The impaction was performed in a cylinder model with an internal diameter of 30 mm and with standardized impaction force using an impactor with a weight of 1450 g. The best particle combination was used for the subsequent computer tomography examination of the cement distribution and the contact surface to the bone in different parts of the shaft in seven investigations. For statistic measurements two-dimensional variance analysis including repetitions of measurement and Bonferroni correction, the LSD post-hoc-zest and the Mann Whitney U Test were used. The error probability was set at α = 5%. The SPSS® for Windows software was used for the statistical analysis. RESULTS The distribution of the cancellous and compacted bone also along the shaft revealed no significant difference between thermodisinfected and native cancellous bone at different levels (p > 0.05). Impacted native cancellous bone showed less inclusion of air, which resulted in a better distribution of density compared with thermodisinfected bone overall (p < 0.001). In the distal shaft area the cement volume was significantly larger in conjunction with the native bone. The overall area of cement penetration appeared to be significantly larger for native cancellous bone (p < 0.001). CONCLUSIONS The impaction of thermodisinfected and native cancellous bone showed greater deformation of the processed bone without any significant difference in the maximum density reached at different levels. Cement volume and cement penetration were pronounced proximally in native and processed cancellous bone. The cement distribution was significantly more distal for the native bone. Distally, the stabilization of the shaft appears to be increasingly dependent on the density of the impacted spongiosa, while proximally, the penetration of the cement into cancellous bone seems to correlate with porosity.
Collapse
|
5
|
Putzer D, Ammann CG, Coraça-Huber D, Lechner R, Schmölz W, Nogler M. The Influence of Liquids on the Mechanical Properties of Allografts in Bone Impaction Grafting. Biopreserv Biobank 2017; 15:410-416. [PMID: 28686464 DOI: 10.1089/bio.2017.0003] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022] Open
Abstract
Allografts are used to compensate for bone defects resulting from revision surgery, tumor surgery, and reconstructive bone surgery. Although it is well known that the reduction of fat content of allografts increases mechanical properties, the content of liquids with a known grain size distribution has not been assessed so far. The aim of the study was to compare the mechanical properties of dried allografts (DA) with allografts mixed with a saline solution (ASS) and with allografts mixed with blood (AB) having a similar grain size distribution. Fresh-frozen morselized bone chips were cleaned chemically, sieved, and reassembled in specific portions with a known grain size distribution. A uniaxial compression was used to assess the yield limit, initial density, density at yield limit, and flowability of the three groups before and after compaction with a fall hammer apparatus. No statistically significant difference could be found for the yield limit between DA and ASS (p = 0.339) and between ASS and AB (p = 0.554). DA showed a statistically significant higher yield limit than AB (p = 0.022). Excluding the effect of the grain size distribution on the mechanical properties, it was shown that allografts have a lower yield limit when lipids are present. The liquid content of allografts seems to play an inferior role as no statistically significant difference could be found between DA and ASS. It is suggested, in accordance with other studies, to chemically clean allografts before implantation to reduce the contamination risk and the fat content.
Collapse
Affiliation(s)
- David Putzer
- 1 Department of Orthopedic Surgery, Experimental Orthopedics, Medical University of Innsbruck , Innsbruck, Austria
| | - Christoph Gert Ammann
- 1 Department of Orthopedic Surgery, Experimental Orthopedics, Medical University of Innsbruck , Innsbruck, Austria
| | - Débora Coraça-Huber
- 1 Department of Orthopedic Surgery, Experimental Orthopedics, Medical University of Innsbruck , Innsbruck, Austria
| | - Ricarda Lechner
- 2 Department of Orthopedic Surgery, Medical University of Innsbruck , Innsbruck, Austria
| | - Werner Schmölz
- 3 Department of Trauma Surgery, Medical University of Innsbruck , Innsbruck, Austria
| | - Michael Nogler
- 1 Department of Orthopedic Surgery, Experimental Orthopedics, Medical University of Innsbruck , Innsbruck, Austria
| |
Collapse
|