Zienkiewicz A, Favre M, Ferdinando H, Iring S, Serrador J, Myllylä T. Blood pressure wave propagation - a multisensor setup for cerebral autoregulation studies.
Physiol Meas 2021;
42. [PMID:
34731844 DOI:
10.1088/1361-6579/ac3629]
[Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/27/2021] [Accepted: 11/03/2021] [Indexed: 11/11/2022]
Abstract
OBJECTIVE
Cerebral autoregulation is critically important to maintain proper brain perfusion and supply the brain with oxygenated blood. Non-invasive measures of blood pressure (BP) are critical in assessing cerebral autoregulation. Wave propogation velocity may be a useful technique to estimate BP but the effect of the location of the sensors on the readings has not been thoroughly examined. In this paper, we were interested to study if propagation velocity of the pressure wave in the direction from the heart to the brain may differ compared with propagation from the heart to the periphery, as well as across different physiological tasks and/or health conditions. Using non-invasive sensors simultaneously placed on different locations of the human body allow for the study of how propagation velocity of the pressure wave, based on pulse transit time (PTT), varies across different directions.
APPROACH
We present multi-sensor BP wave propagation measurement setup aimed for cerebral autoregulation studies. The presented sensor setup consists of three sensors, one each placed on the neck, chest and finger, allowing simultaneous measurement of changes in BP propagation velocity towards the brain and to the periphery. We show how commonly tested physiological tasks affect the relative changes of PTT and correlations with BP.
MAIN RESULTS
We observed that during maximal blow, valsalva and breath hold breathing tasks, the relative changes of PTT were higher when PTT was measured in the direction from the heart to the brain than from the heart to the peripherals. In contrast, during a deep breathing task, the relative change in PTT from the heart to the brain was lower. In addition, we present a short literature review of PTT methods used in brain research.
SIGNIFICANCE
These preliminary data suggest that physiological task and direction of PTT measurement may affect relative PTT changes. Presented three-sensor setup provides an easy and neuroimaging compatible method for cerebral autoregulation studies by allowing to measure BP wave propagation velocity towards the brain vs. towards the periphery.
Collapse