1
|
Mankertz F, Künnemann MD, Reekers J, Hering JP. [CT Protocols in Thoracic Surgery: a Practical Guideline]. Zentralbl Chir 2025. [PMID: 40359990 DOI: 10.1055/a-2587-2568] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 05/15/2025]
Abstract
The use of radiological imaging has gained increasing importance in thoracic surgery, due to the development of new modalities. In particular, computed tomography (CT) not only offers significant diagnostic value but has also become essential for preoperative planning and postoperative follow-up in thoracic surgery. This review is intended to serve as a practical reference and guide for the indication, planning, and interpretation of thoracic CT imaging. It not only explains diagnostic aspects, such as the evaluation of specific conditions in CT imaging, but also provides practical guidance on how to formulate specific clinical questions. The appropriate indication for contrast-enhanced CT versus non-contrast imaging is evaluated. Additionally, the various contrast phases in CT imaging and their diagnostic relevance are discussed using specific thoracic surgery cases. The goal is to provide a structured guide for the application and assessment of radiological diagnostics in thoracic surgery.
Collapse
Affiliation(s)
- Fiona Mankertz
- Abteilung für Diagnostische und Interventionelle Radiologie, Universitätsklinikum Tübingen, Tübingen, Deutschland
| | | | - Johanna Reekers
- Klinik für Radiologie und Neuroradiologie, Klinikum Ibbenbüren gGmbH, Ibbenbüren, Deutschland
| | - Jan Philipp Hering
- Klinik für Radiologie und Neuroradiologie, Klinikum Ibbenbüren gGmbH, Ibbenbüren, Deutschland
| |
Collapse
|
2
|
Zhang H, Liu M, Shi X, Ma J, Ren C, Huang Z, Wang Y, Jing H, Huo L. Feasibility of a deep-inspiration breath-hold [ 18F]AlF-NOTA-LM3 PET/CT imaging on upper-abdominal lesions in NET patients: in comparison with respiratory-gated PET/CT. EJNMMI Phys 2024; 11:75. [PMID: 39207609 PMCID: PMC11362407 DOI: 10.1186/s40658-024-00677-5] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/14/2024] [Accepted: 08/05/2024] [Indexed: 09/04/2024] Open
Abstract
PURPOSES To explore the clinical feasibility and efficacy of a deep inspiration breath-hold (BH) PET/CT using [18F]AlF-NOTA-LM3 on upper abdominal lesions in patients with neuroendocrine tumors (NETs). METHODS Twenty-three patients underwent a free-breath (FB) whole-body PET/CT, including a 10 min/bed scan for the upper abdomen with a vital signal monitoring for respiratory gating (RG) followed by a 20-second BH PET/CT covering the same axial range. For the upper abdomen bed, the following PET series was reconstructed: a 2-min FB PET; RG PET (6 bins); a 20-second and 15-second BH PET (BH_15 and BH_20). Semi-quantitative analysis was performed to compare liver SUVmean, lesion SUVmax, MTV, its percentage difference and target-to-background ratio (TBR) between both BH PET and RG PET images. Subgroup analysis considered lesion location, MTV and SUVmax. A 5-point Likert scale was used to perform visual analysis and any missed or additional lesions were identified compared with RG PET. RESULTS Quantitative analysis on overall lesions (n = 78) revealed higher SUVmax and TBR, and smaller MTV for both BH PET compared to FB and RG PET, with lesion location-specific variations. Neither significant difference was observed in all metrics between RG and FB PET in larger lesions, nor in MTV in lower-uptake lesions. However, both BH PET significantly enhanced these measurements. In the visual analysis, both BH PET showed noninferior performance to RG PET, and were evaluated clinically acceptable. Additional and missed lesions were observed in FB and both BH PET compared with RG PET, but didn't alter the clinical management. The BH_15 PET showed comparable performance to BH_20 PET in any comparison. CONCLUSION The BH PET/CT using [18F]AlF-NOTA-LM3 is effective in detecting upper abdominal lesions, offering more accurate quantitative measurements. Using a novel PET/CT scanner, a 15-second BH PET can provide comparable and superior performance to RG PET, indicating potential feasibility in clinical routines.
Collapse
Affiliation(s)
- Haiqiong Zhang
- Department of Nuclear Medicine, State Key Laboratory of Complex Severe and Rare Diseases, Beijing Key Laboratory of Molecular Targeted Diagnosis and Therapy in Nuclear Medicine, Peking Union Medical College Hospital, Chinese Academy of Medical Sciences, Beijing, 100730, China
| | - Meixi Liu
- Department of Nuclear Medicine, State Key Laboratory of Complex Severe and Rare Diseases, Beijing Key Laboratory of Molecular Targeted Diagnosis and Therapy in Nuclear Medicine, Peking Union Medical College Hospital, Chinese Academy of Medical Sciences, Beijing, 100730, China
| | - Ximin Shi
- Department of Nuclear Medicine, State Key Laboratory of Complex Severe and Rare Diseases, Beijing Key Laboratory of Molecular Targeted Diagnosis and Therapy in Nuclear Medicine, Peking Union Medical College Hospital, Chinese Academy of Medical Sciences, Beijing, 100730, China
| | - Jiangyu Ma
- Department of Nuclear Medicine, State Key Laboratory of Complex Severe and Rare Diseases, Beijing Key Laboratory of Molecular Targeted Diagnosis and Therapy in Nuclear Medicine, Peking Union Medical College Hospital, Chinese Academy of Medical Sciences, Beijing, 100730, China
| | - Chao Ren
- Department of Nuclear Medicine, State Key Laboratory of Complex Severe and Rare Diseases, Beijing Key Laboratory of Molecular Targeted Diagnosis and Therapy in Nuclear Medicine, Peking Union Medical College Hospital, Chinese Academy of Medical Sciences, Beijing, 100730, China
| | - Zhenghai Huang
- Department of Nuclear Medicine, State Key Laboratory of Complex Severe and Rare Diseases, Beijing Key Laboratory of Molecular Targeted Diagnosis and Therapy in Nuclear Medicine, Peking Union Medical College Hospital, Chinese Academy of Medical Sciences, Beijing, 100730, China
| | - Ying Wang
- Central Research Institute, United Imaging Healthcare, Shanghai, 201815, China
| | - Hongli Jing
- Department of Nuclear Medicine, State Key Laboratory of Complex Severe and Rare Diseases, Beijing Key Laboratory of Molecular Targeted Diagnosis and Therapy in Nuclear Medicine, Peking Union Medical College Hospital, Chinese Academy of Medical Sciences, Beijing, 100730, China
| | - Li Huo
- Department of Nuclear Medicine, State Key Laboratory of Complex Severe and Rare Diseases, Beijing Key Laboratory of Molecular Targeted Diagnosis and Therapy in Nuclear Medicine, Peking Union Medical College Hospital, Chinese Academy of Medical Sciences, Beijing, 100730, China.
| |
Collapse
|
3
|
Iwasa H, Nagamachi S, Nakayama S, Yamamoto T, Yoshimitsu K. The reproducibility of MTV and TLG of soft tissue tumors calculated by FDG-PET: Comparison between the lower limit by the fixed value SUV 2.5 and that value by 30% of SUVmax. Jpn J Radiol 2023; 41:531-540. [PMID: 36637680 PMCID: PMC10147792 DOI: 10.1007/s11604-022-01378-8] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/02/2022] [Accepted: 12/22/2022] [Indexed: 01/14/2023]
Abstract
PURPOSE We evaluated the reproducibility calculating volume-based FDG-PET/CT parameters, i.e., metabolic tumor volume (MTV) and total lesion glycolysis (TLG), in soft tissue tumors. MATERIALS AND METHODS Fifty-three cases with soft tissue tumors were analyzed retrospectively. The conditions determining the lower limit of MTV were fixed value SUV 2.5 or 30% of SUVmax. To investigate the agreement of the measurements by two radiologists, %difference, the correlation coefficients and Bland-Altman plot were analyzed. We compared these parameters in both intra- and inter-operator for evaluating the agreement in the measurements. RESULTS The values of % difference were excellent, 0.2-3.5%, in the intra-operator in all calculated volume-based parameters. In both inter- and intra-operator analysis, the values of % differences were lower in the parameters calculated by SUV 2.5 fixed value as a lower threshold compared with those calculated by 30% of SUVmax as a lower threshold. The correlation coefficient in MTV30% for inter-operator were 0.84 or 0.87, those were lower than values by the intra-operator evaluation. Nevertheless, the correlation coefficients were higher than 0.84 in every parameter. Particularly, correlation coefficient in the parameters calculated by SUV 2.5 fixed value was better than those calculated by 30% of SUVmax. The Bland-Altman plot analysis showed good agreement for all parameters, particularly in the intra-operator examinations. However, in the inter-operator study, some variances were noted in every condition. CONCLUSION In conclusion, the reproducibility of measuring volume-based FDG-PET/CT parameters of soft tissue tumors was good, particularly, in the measurement by fixed lower limit value SUV 2.5 in the intra-operator.
Collapse
Affiliation(s)
- Hitomi Iwasa
- Department of Radiology, Faculty of Medicine, Fukuoka University, 7-45-1 Nanakuma, Jonan-Ku, Fukuoka, 814-0180, Japan.,Department of Diagnostic and Interventional Radiology, Kochi Medical School, Kochi University, Kochi, Japan
| | - Shigeki Nagamachi
- Department of Radiology, Faculty of Medicine, Fukuoka University, 7-45-1 Nanakuma, Jonan-Ku, Fukuoka, 814-0180, Japan.
| | - Shizuhide Nakayama
- Department of Orthopedic Surgery, Faculty of Medicine, Fukuoka University, Fukuoka, Japan
| | - Takuaki Yamamoto
- Department of Orthopedic Surgery, Faculty of Medicine, Fukuoka University, Fukuoka, Japan
| | - Kengo Yoshimitsu
- Department of Radiology, Faculty of Medicine, Fukuoka University, 7-45-1 Nanakuma, Jonan-Ku, Fukuoka, 814-0180, Japan
| |
Collapse
|
4
|
Kang SY, Moon BS, Kim HO, Yoon HJ, Kim BS. The impact of data-driven respiratory gating in clinical F-18 FDG PET/CT: comparison of free breathing and deep-expiration breath-hold CT protocol. Ann Nucl Med 2021; 35:328-337. [PMID: 33449303 DOI: 10.1007/s12149-020-01574-4] [Citation(s) in RCA: 14] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/21/2020] [Accepted: 12/09/2020] [Indexed: 12/25/2022]
Abstract
BACKGROUND Respiratory motion can diminish PET image quality and lead to inaccurate lesion quantifications. Data-driven gating (DDG) was recently introduced as an effective respiratory gating technique for PET. In the current study, we investigated the clinical impact of DDG on respiratory movement in 18F-FDG PET/CT. METHOD PET list-mode data were collected for each subject and DDG software was utilized for extracting respiratory waveforms. PET images was reconstructed using Q.clear and Q.clear + DDG, respectively. We evaluated SUVmax, SUVmean, the coefficient of variance (CoV), metabolic tumor volume (MTV), and tumor heterogeneity using the area under the curve of cumulative SUV histogram (AUC-CSH). Metabolic parameter changes were compared between each reconstruction method. The Deep-Expiration Breath Hold (DEBH) protocol was introduced for CT scans to correct spatial misalignment between PET and CT and compared with conventional free breathing. The DEBH and free breathing (FB) protocol comparison was made in a separate matching cohort using propensity core matching rather than the same patient. RESULTS Total 147 PET/CT scans with excessive respiratory movements were used to study DDG-mediated correction. After DDG application, SUVmax (P < 0.0001; 8.15 ± 4.77 vs. 9.03 ± 5.02) and SUVmean (P < 0.0001; 4.91 ± 2.44 vs. 5.49 ± 2.68) of lung and upper abdomen lesions increased, while MTV significantly decreased (P < 0.0001; 7.07 ± 15.46 vs. 6.58 ± 15.14). In addition, the percent change of SUVs was greater in lower lung lesions compared to upper lobe lesions. Likewise, the MTV reduction was significantly greater in lower lobe lesions. No significant difference dependent on location was observed in liver lesions. DEBH-mediated CT breathing correction did not make a significant difference in lesion metabolic parameters compared to conventional free breathing. CONCLUSIONS These results suggest that DDG correction enables more corrected quantification from respiratory movements for lesions located in the lung and upper abdomen. Therefore, we suggest that DDG is worth using as a standard protocol during 18F-FDG PET/CT imaging.
Collapse
Affiliation(s)
- Seo Young Kang
- Department of Nuclear Medicine, College of Medicine, Ewha Womans University Medical Center, (07804) 260, Gonghang-daero, Gangseo-gu, Seoul, Republic of Korea
| | - Byung Seok Moon
- Department of Nuclear Medicine, College of Medicine, Ewha Womans University Medical Center, (07804) 260, Gonghang-daero, Gangseo-gu, Seoul, Republic of Korea
| | - Hye Ok Kim
- Department of Nuclear Medicine, College of Medicine, Ewha Womans University Medical Center, (07804) 260, Gonghang-daero, Gangseo-gu, Seoul, Republic of Korea
| | - Hai-Jeon Yoon
- Department of Nuclear Medicine, College of Medicine, Ewha Womans University Medical Center, (07804) 260, Gonghang-daero, Gangseo-gu, Seoul, Republic of Korea
| | - Bom Sahn Kim
- Department of Nuclear Medicine, College of Medicine, Ewha Womans University Medical Center, (07804) 260, Gonghang-daero, Gangseo-gu, Seoul, Republic of Korea.
| |
Collapse
|
5
|
Bärwolf R, Zirnsak M, Freesmeyer M. Breath-hold and free-breathing F-18-FDG-PET/CT in malignant melanoma-detection of additional tumoral foci and effects on quantitative parameters. Medicine (Baltimore) 2017; 96:e5882. [PMID: 28079829 PMCID: PMC5266191 DOI: 10.1097/md.0000000000005882] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/02/2022] Open
Abstract
During PET/CT acquisition, respiratory motion generates artifacts in the form of breath-related blurring, which may impair lesion detectability and diagnostic accuracy. This observational study was undertaken to verify whether breath-hold F-18-FDG-PET/CT (bhPET) detects additional foci compared to free-breathing PET/CT (fbPET) in cases of malignant melanoma, and to assess the impact of breath-holding on standard uptake values (SUV) and metabolic isocontoured volume (mVic40).Thirty-four patients with melanoma were examined. BhPET and fbPET findings of 117 lesions were compared and correlated with standard contrast-enhanced (ce) CT and MRI for lesion verification. Quantitative parameters (SUVmax, SUVmean, and mVic40) were assessed for both methods and evaluated by linear regression and Spearman correlation. The impact of lesion size and time interval between investigations was analyzed.In 1 patient, a CT-confirmed liver metastasis was seen only on bhPET but not on fbPET. At bhPET, SUVmax, and SUVmean proved significantly higher and mVic40 significantly lower than at fbPET. The positive effect on SUVmax and SUVmean was more pronounced in smaller lesions, whereas the time interval between bhPET and fbPET did not influence SUV or mVic40.In our patient cohort, bhPET yielded significantly higher SUV and provided improved volumetric lesion definition, particularly of smaller lesions. Also one additional liver lesion was identified. Breath-hold PET/CT is technically feasible, and may become clinically useful when fine quantitative evaluations are needed.
Collapse
|
6
|
Zirnsak M, Bärwolf R, Freesmeyer M. Breath-hold [68Ga]DOTA-TOC PET/CT in neuroendocrine tumors: detection of additional lesions and effects on quantitative parameters. THE QUARTERLY JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING : OFFICIAL PUBLICATION OF THE ITALIAN ASSOCIATION OF NUCLEAR MEDICINE (AIMN) [AND] THE INTERNATIONAL ASSOCIATION OF RADIOPHARMACOLOGY (IAR), [AND] SECTION OF THE SOCIETY OF RADIOPHARMACEUTICAL CHEMISTRY AND BIOLOGY 2016; 63:292-301. [PMID: 27824238 DOI: 10.23736/s1824-4785.16.02922-8] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
Abstract
BACKGROUND Respiratory motion during PET/CT acquisition generates artifacts in the form of breath-related blurring, which influences the lesion detectability and diagnostic accuracy. The goal of this study was to verify whether breath-hold [68Ga]DOTA-TOC PET/CT (bhPET) allows detection of additional foci compared to free-breathing PET/CT (fbPET), and to assess the impact of breath-holding on standard uptake values (SUV) and isocontoured volume (Vic40) in patients with neuroendocrine tumors (NET). METHODS Patients with NET (N.=39) were included in this study. BhPET and fbPET characteristics of 96 lesions were compared, and correlated with standard contrast-enhanced (ce) CT and MRI for lesion verification. Quantitative parameters SUV (max and mean) and Vic40 were assessed for both methods and evaluated by linear regression and Spearman's correlation. The impact of lesion size, localization and time interval between investigations was also analyzed. RESULTS bhPET identified one additional metastasis not seen at fbPET but visible at ceMRI. Another additional bhPET focus did not have a morphological correlate. At bhPET, the SUVmax and SUVmean proved significantly higher and the Vic40 significantly lower than at fbPET. Lesion size, localization and time intervals did not impact significantly on SUV or Vic40. CONCLUSIONS Currently, routine use of breath-hold [68Ga]DOTA-TOC PET/CT cannot be recommended as only one additional lesion was identified. Therefore, bhPET has currently no indication in patients with NET. If technical improvements regarding PET/CT scanner sensitivity are available, bhPET should be reevaluated in the future.
Collapse
Affiliation(s)
- Mariana Zirnsak
- Clinic of Nuclear Medicine, Jena University Hospital, Jena, Germany
| | - Robert Bärwolf
- Clinic of Nuclear Medicine, Jena University Hospital, Jena, Germany
| | - Martin Freesmeyer
- Clinic of Nuclear Medicine, Jena University Hospital, Jena, Germany -
| |
Collapse
|
7
|
Li G, Schmidtlein CR, Burger IA, Ridge CA, Solomon SB, Humm JL. Assessing and accounting for the impact of respiratory motion on FDG uptake and viable volume for liver lesions in free-breathing PET using respiration-suspended PET images as reference. Med Phys 2015; 41:091905. [PMID: 25186392 DOI: 10.1118/1.4892602] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022] Open
Abstract
PURPOSE To assess and account for the impact of respiratory motion on the variability of activity and volume determination of liver tumor in positron emission tomography (PET) through a comparison between free-breathing (FB) and respiration-suspended (RS) PET images. METHODS As part of a PET/computed tomography (CT) guided percutaneous liver ablation procedure performed on a PET/CT scanner, a patient's breathing is suspended on a ventilator, allowing the acquisition of a near-motionless PET and CT reference images of the liver. In this study, baseline RS and FB PET/CT images of 20 patients undergoing thermal ablation were acquired. The RS PET provides near-motionless reference in a human study, and thereby allows a quantitative evaluation of the effect of respiratory motion on PET images obtained under FB conditions. Two methods were applied to calculate tumor activity and volume: (1) threshold-based segmentation (TBS), estimating the total lesion glycolysis (TLG) and the segmented volume and (2) histogram-based estimation (HBE), yielding the background-subtracted lesion (BSL) activity and associated volume. The TBS method employs 50% of the maximum standardized uptake value (SUVmax) as the threshold for tumors with SUVmax≥2× SUVliver-bkg, and tumor activity above this threshold yields TLG50%. The HBE method determines local PET background based on a Gaussian fit of the low SUV peak in a SUV-volume histogram, which is generated within a user-defined and optimized volume of interest containing both local background and lesion uptakes. Voxels with PET intensity above the fitted background were considered to have originated from the tumor and used to calculate the BSL activity and its associated lesion volume. RESULTS Respiratory motion caused SUVmax to decrease from RS to FB by -15%±11% (p=0.01). Using TBS method, there was also a decrease in SUVmean (-18%±9%, p=0.01), but an increase in TLG50% (18%±36%) and in the segmented volume (47%±52%, p=0.01) from RS to FB PET images. The background uptake in normal liver was stable, 1%±9%. In contrast, using the HBE method, the differences in both BSL activity and BSL volume from RS to FB were -8%±10% (p=0.005) and 0%±16% (p=0.94), respectively. CONCLUSIONS This is the first time that almost motion-free PET images of the human liver were acquired and compared to free-breathing PET. The BSL method's results are more consistent, for the calculation of both tumor activity and volume in RS and FB PET images, than those using conventional TBS. This suggests that the BSL method might be less sensitive to motion blurring and provides an improved estimation of tumor activity and volume in the presence of respiratory motion.
Collapse
Affiliation(s)
- Guang Li
- Department of Medical Physics, Memorial Sloan Kettering Cancer Center, New York, New York 10065
| | - C Ross Schmidtlein
- Department of Medical Physics, Memorial Sloan Kettering Cancer Center, New York, New York 10065
| | - Irene A Burger
- Department of Radiology, University Hospital of Zurich, CH-8091 Zurich, Switzerland
| | - Carole A Ridge
- Department of Radiology, Memorial Sloan-Kettering Cancer Center, New York, New York 10065
| | - Stephen B Solomon
- Department of Radiology, Memorial Sloan-Kettering Cancer Center, New York, New York 10065
| | - John L Humm
- Department of Medical Physics, Memorial Sloan Kettering Cancer Center, New York, New York 10065
| |
Collapse
|
8
|
Miwa K. [Management of respiratory motion in FDG-PET/CT: respiratory-gated and deep-inspiration breath-hold techniques]. Nihon Hoshasen Gijutsu Gakkai Zasshi 2014; 70:1344-52. [PMID: 25410343 DOI: 10.6009/jjrt.2014_jsrt_70.11.1344] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
|
9
|
Abstract
Combined PET/computed tomography (CT) is of value in cancer diagnosis, follow-up, and treatment planning. For cancers located in the thorax or abdomen, the patient’s breathing causes artifacts and errors in PET and CT images. Many different approaches for artifact avoidance or correction have been developed; most are based on gated acquisition and synchronization between the respiratory signal and PET acquisition. The respiratory signal is usually produced by an external sensor that tracks a physiological characteristic related to the patient’s breathing. Respiratory gating is a compensation technique in which time or amplitude binning is used to exclude the motion in reconstructed PET images. Although this technique is performed in routine clinical practice, it fails to adequately correct for respiratory motion because each gate can mix several tissue positions. Researchers have suggested either selecting PET events from gated acquisitions or performing several PET acquisitions (corresponding to a breath-hold CT position). However, the PET acquisition time must be increased if adequate counting statistics are to be obtained in the different gates after binning. Hence, other researchers have assessed correction techniques that take account of all the counting statistics (without increasing the acquisition duration) and integrate motion information before, during, or after the reconstruction process. Here, we provide an overview of how motion is managed to overcome respiratory motion in PET/CT images.
Collapse
|
10
|
Respiratory motion reduction in PET/CT using abdominal compression for lung cancer patients. PLoS One 2014; 9:e98033. [PMID: 24837352 PMCID: PMC4024027 DOI: 10.1371/journal.pone.0098033] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/28/2014] [Accepted: 04/14/2014] [Indexed: 12/25/2022] Open
Abstract
Purpose Respiratory motion causes substantial artifacts in reconstructed PET images when using helical CT as the attenuation map in PET/CT imaging. In this study, we aimed to reduce the respiratory artifacts in PET/CT images of patients with lung tumors using an abdominal compression device. Methods Twelve patients with lung cancer located in the middle or lower lobe of the lung were recruited. The patients were injected with 370 MBq of 18F-FDG. During PET, the patients assumed two bed positions for 1.5 min/bed. After conducting free-breathing imaging, we obtained images of the patients with abdominal compression by applying the same setup used in the free-breathing scan. The differences in the standardized uptake value (SUV)max, SUVmean, tumor volume, and the centroid of the tumors between PET and various CT schemes were measured. Results The SUVmax and SUVmean derived from PET/CT imaging using an abdominal compression device increased for all the lesions, compared with those obtained using the conventional approach. The percentage increases were 18.1% ±14% and 17% ±16.8% for SUVmax and SUVmean, respectively. PET/CT imaging combined with abdominal compression generally reduced the tumor mismatch between CT and the corresponding attenuation corrected PET images, with an average decrease of 1.9±1.7 mm over all the cases. Conclusions PET/CT imaging combined with abdominal compression reduces respiratory artifacts and PET/CT misregistration, and enhances quantitative SUV in tumor. Abdominal compression is easy to set up and is an effective method used in PET/CT imaging for clinical oncology, especially in the thoracic region.
Collapse
|
11
|
Bettinardi V, Picchio M, Di Muzio N, Gilardi MC. Motion management in positron emission tomography/computed tomography for radiation treatment planning. Semin Nucl Med 2012; 42:289-307. [PMID: 22840595 DOI: 10.1053/j.semnuclmed.2012.04.001] [Citation(s) in RCA: 26] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/25/2022]
Abstract
Hybrid positron emission tomography (PET)/computed tomography (CT) scanners combine, in a unique gantry, 2 of the most important diagnostic imaging systems, a CT and a PET tomograph, enabling anatomical (CT) and functional (PET) studies to be performed in a single study session. Furthermore, as the 2 scanners use the same spatial coordinate system, the reconstructed CT and PET images are spatially co-registered, allowing an accurate localization of the functional signal over the corresponding anatomical structure. This peculiarity of the hybrid PET/CT system results in improved tumor characterization for oncological applications, and more recently, it was found to be also useful for target volume definition (TVD) and treatment planning in radiotherapy (RT) applications. In fact, the use of combined PET/CT information has been shown to improve the RT treatment plan when compared with that obtained by a CT alone. A limiting factor to the accuracy of TVD by PET/CT is organ and tumor motion, which is mainly due to patient respiration. In fact, respiratory motion has a degrading effect on PET/CT image quality, and this is also critical for TVD, as it can lead to possible tumor missing or undertreatment. Thus, the management of respiratory motion is becoming an increasingly essential component in RT treatment planning; indeed, it has been recognized that the use of personalized motion information can improve TVD and, consequently, permit increased tumor dosage while sparing surrounding healthy tissues and organs at risk. This review describes the methods used for motion management in PET/CT for radiation treatment planning. The article covers the following: (1) problems caused by organ and lesion motion owing to respiration, and the artifacts generated on CT, PET, and PET/CT images; (2) data acquisition and processing techniques used to manage respiratory motion in PET/CT studies; and (3) the use of personalized motion information for TVD and radiation treatment planning.
Collapse
Affiliation(s)
- Valentino Bettinardi
- Department of Nuclear Medicine, Scientific Institute San Raffaele, Segrate, Milan, Italy.
| | | | | | | |
Collapse
|
12
|
Sun T, Mok GSP. Techniques for respiration-induced artifacts reductions in thoracic PET/CT. Quant Imaging Med Surg 2012; 2:46-52. [PMID: 23256058 PMCID: PMC3496495 DOI: 10.3978/j.issn.2223-4292.2012.02.01] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/25/2012] [Accepted: 02/01/2012] [Indexed: 01/25/2023]
Abstract
The advent of positron emission tomography/computed tomography (PET/CT) provides fusion of both anatomical and functional information. CT-based attenuation correction replaced (68)Ge-based attenuation correction for shortening acquisition time, improving image quality and quantitative accuracy. However, due to the temporal difference of PET and CT, mis-registration and motion artifacts are observed in the attenuation-corrected images mainly due to the respiratory motion. Reducing the spatial mismatch of the PET and CT reconstructed image remains a challenge. This review provides an introduction to various respiratory image artifacts reduction techniques especially for thoracic lesions, including breathing instruction based methods, CT protocol based methods and 4-dimensional PET/CT. The advantages and drawbacks of different methods are also discussed.
Collapse
Affiliation(s)
- Tao Sun
- Department of Electrical and Computer Engineering, Faculty of Science and Technology, University of Macau, Macau SAR, China
| | | |
Collapse
|
13
|
|
14
|
Kawano T, Ohtake E, Inoue T. Deep-inspiration breath-hold PET/CT versus free breathing PET/CT and respiratory gating PET for reference: evaluation in 95 patients with lung cancer. Ann Nucl Med 2010; 25:109-16. [PMID: 21080119 DOI: 10.1007/s12149-010-0442-2] [Citation(s) in RCA: 20] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/11/2010] [Accepted: 09/22/2010] [Indexed: 10/18/2022]
Abstract
OBJECTIVE The objective of this study was to define the factors that correlate with differences in maximum standardized uptake value (SUV(max)) in deep-inspiration breath-hold (DIBH) and free breathing (FB) PET/CT admixed with respiratory gating (RG) PET for reference. METHODS Patients (n = 95) with pulmonary lesions were evaluated at one facility over 33 months. After undergoing whole-body PET/CT, a RG PET and FB PET/CT scans were obtained, followed by a DIBH PET/CT scan. All scans were recorded using a list-mode dynamic collection method with respiratory gating. The RG PET was reconstructed using phase gating without attenuation correction; the FB PET was reconstructed from the RG PET sinogram datasets with attenuation correction. Respiratory motion distance, breathing cycle speed, and waveform of RG PET were recorded. The SUV(max) of FB PET/CT and DIBH PET/CT were recorded: the percent difference in SUV(max) between the FB and DIBH scans was defined as the %BH-index. RESULTS The %BH-index was significantly higher for lesions in the lower lung area than in the upper lung area. Respiratory motion distance was significantly higher in the lower lung area than in the upper lung area. A significant relationship was observed between the %BH-index and respiratory motion distance. Waveforms without steady end-expiration tended to show a high %BH-index. Significant inverse relationships were observed between %BH-index and cycle speed, and between respiratory motion distance and cycle speed. CONCLUSION Decrease in SUV(max) of FB PET/CT was due to (1) tumor size, (2) distribution of lower lung, (3) long respiratory movement at slow breathing cycle speeds, and (4) respiratory waveforms without steady end-expiration.
Collapse
Affiliation(s)
- Tsuyoshi Kawano
- Division of Nuclear Medicine, Kanagawa Cancer Center, Nakao 1-1-2, Asahi-ku, Yokohama 241-0815, Japan.
| | | | | |
Collapse
|