1
|
Costa FS, Moreira LS, Ludovico LL, Volpe J, de Oliveira AC, Dos Santos MP, da Silva EGP, Souto DEP, Grassi MT, Gonzalez MH, Amaral CDB. Microwave-assisted extraction based on emulsion breaking with natural deep eutectic solvent for vegetable oil sample preparation prior to elemental determination by ICP OES. Talanta 2024; 266:125108. [PMID: 37651914 DOI: 10.1016/j.talanta.2023.125108] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/28/2023] [Revised: 08/16/2023] [Accepted: 08/22/2023] [Indexed: 09/02/2023]
Abstract
This study presents a novel and efficient method for the extraction of Al, Ca, Cr, Cu, K, Mg, Mn, and Zn in vegetable oil samples using a Natural Deep Eutectic Solvent (NADES) as an extractor combined with microwave radiation (MW) in an emulsion system. The NADES prepared with choline chloride:oxalic acid:water (1:1:4 molar ratio) provided a high extraction rate using 5.0 mL of the sample, 1.7 mL of NADES, and 1.3 mL of Triton X-100. The optimum conditions were obtained with 36 s of vortexing, 5 min of extraction, and 10 s for emulsion-breaking in MW. Under these conditions, recoveries ranged from 91% to 110% and relative standard deviations <9.0% were obtained. The limit of quantification (mg kg-1) was: 0.018 (Al), 0.032 (Ca), 0.007 (Cr), 0.006 (Cu), 0.013 (K), 0.027 (Mg), 0.002 (Mn), and 0.019 (Zn). The proposed method showed comparable results to reference methods and advantages, such as speed, low cost, and simplicity. The combination of NADES and MW represents a sustainable and innovative approach to the elemental determination composition of vegetable oils and contributes to advances in sample preparation methods.
Collapse
Affiliation(s)
| | - Luana Santos Moreira
- Department of Chemistry, Federal University of Paraná, Curitiba, PR, 81531-980, Brazil; Department of Chemistry, Federal University of Espírito Santo, Vitória, ES, 29075-910, Brazil
| | - Letícia Lima Ludovico
- Department of Chemistry, Federal University of Paraná, Curitiba, PR, 81531-980, Brazil
| | - Jaqueline Volpe
- Department of Chemistry, Federal University of Paraná, Curitiba, PR, 81531-980, Brazil
| | | | | | | | | | - Marco Tadeu Grassi
- Department of Chemistry, Federal University of Paraná, Curitiba, PR, 81531-980, Brazil
| | - Mario Henrique Gonzalez
- Department of Chemistry and Environmental Science, National Institute for Alternative Technologies of Detection, Toxicological Evaluation and Removal of Micropollutants and Radioactives (INCT-DATREM), São Paulo State University (UNESP), São José do Rio Preto, SP, 15054-000, Brazil
| | - Clarice D B Amaral
- Department of Chemistry, Federal University of Paraná, Curitiba, PR, 81531-980, Brazil.
| |
Collapse
|
2
|
da Mata Cerqueira UMF, Valasques GS, de Souza CT, Araújo SA, Bezerra MA, Novaes CG. Extraction Induced by Emulsion Breaking for Ca, Fe, Mg, and Zn Determination in Edible Oils Using High-Resolution Continuous Source Flame Atomic Absorption Spectrometry. FOOD ANAL METHOD 2022. [DOI: 10.1007/s12161-021-02216-9] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/04/2022]
|
3
|
Adolfo FR, Nascimento PCD. Extraction Induced by Emulsion and Microemulsion Breaking for Metal Determination by Spectrometric Methods - A Review. Crit Rev Anal Chem 2022; 53:1374-1392. [PMID: 34991390 DOI: 10.1080/10408347.2021.2023352] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 08/24/2023]
Abstract
This review focuses on extraction induced by the destabilization of emulsified systems combined with spectrometric techniques for metal analysis in oily samples. This approach is based on the formation and breaking of an emulsion (extraction induced by emulsion breaking - EIEB) or microemulsion (extraction induced by microemulsion breaking - EIMB) to transfer the analytes from the oil sample to the aqueous phase, which is separated in the process. Its simplicity, speed, and low cost have contributed to its growing popularity among researchers. However, the potential of EIEB and EIMB is far from being fully exploited. Therefore, this paper aims to provide relevant information to expand the applicability of these methods. The principle of the methods is discussed, and a brief description of emulsified systems is presented. The parameters affecting the extraction efficiency and calibration strategy are also critically discussed. Furthermore, the analytical applications of the methods are reviewed. Trends and opportunities in this field are also considered.
Collapse
Affiliation(s)
- Franciele Rovasi Adolfo
- Departamento de Química, Universidade Federal de Santa Maria, Santa Maria, Rio Grande do Sul, Brasil
| | | |
Collapse
|