1
|
Zajc J, Fokter SK. Bimodular femoral stems in primary total hip arthroplasty. Expert Rev Med Devices 2023; 20:1051-1064. [PMID: 37753590 DOI: 10.1080/17434440.2023.2264177] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/19/2023] [Accepted: 09/25/2023] [Indexed: 09/28/2023]
Abstract
INTRODUCTION This review critically examines the efficacy of dual-modular stems in primary total hip arthroplasty. Given the variability and non-comparability of certain femoral stem designs and stem-neck couplings, with some even being withdrawn from the market, this review offers an in-depth analysis of predominant implant performances. AREAS COVERED The paper explores a brief historical summary related to dual-modular stems, including the complications associated with their use, diagnostic tools for evaluation, analysis of both recalled and currently available models, as well as alternative therapeutic options. This information is pertinent for both clinical and research domains. EXPERT OPINION While dual-modular systems were initially touted to offer several advantages, the evidence substantiating these benefits has been ambiguous. Further, these systems introduce the risk of alternative complications. In specific cases involving patients with developmental hip dysplasia and certain proximal femoral deformities requiring complex reconstructions, dual-modular systems might be relevant. Nonetheless, the use of long interchangeable necks in patients with a body mass index above 30 kg/m2 is discouraged, and pairing a long varus-oriented neck with an extra-long femoral head should be avoided in all patients.
Collapse
Affiliation(s)
- Jan Zajc
- Clinical Department of Orthopedic Surgery, University Medical Center Maribor, Maribor, Slovenia
- Faculty of Medicine, University of Maribor, Maribor, Slovenia
| | - Samo K Fokter
- Clinical Department of Orthopedic Surgery, University Medical Center Maribor, Maribor, Slovenia
- Faculty of Medicine, University of Maribor, Maribor, Slovenia
| |
Collapse
|
2
|
Trunnions and Modularity in Total Hip Arthroplasty: A Historical Review With Current Clinical Implications. J Am Acad Orthop Surg 2023; 31:189-197. [PMID: 36728328 DOI: 10.5435/jaaos-d-22-00498] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/07/2022] [Accepted: 11/27/2022] [Indexed: 02/03/2023] Open
Abstract
Trunnion in total hip arthroplasty refers to the interface between the neck of a femoral stem and the femoral head. Clinical complications arising from damage to this junction, whether it be due to mechanical wear, corrosion, or a combination, are referred to as mechanically assisted crevice corrosion (MACC), also commonly known as trunnionosis. With the use of modular hip prostheses, which help customize offset and leg length to an individual patient's anatomy, the incidence of MACC and revision due to MACC has increased in recent years. Although the cause of MACC is multifactorial, with patient factors and technique factors contributing to this condition, taper design and geometry, metallurgical properties of implants, and size mismatch of the bearing couple are some of the implant factors that have also been implicated in this clinical phenomenon. Understanding the history of taper design and geometry, the track record of older implants, and the rationale behind the development of current prostheses can help surgeons choose the right implants for their patients and accurately assess the pros and cons of new implants being introduced to the market each year.
Collapse
|
3
|
Klemt C, Limmahakhun S, Bounajem G, Melnic CM, Harvey MJ, Kwon YM. Outcome of revision surgery for adverse local tissue reactions in patients with recalled total hip arthroplasty. Arch Orthop Trauma Surg 2022; 142:2577-2583. [PMID: 33837474 DOI: 10.1007/s00402-021-03891-3] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/01/2020] [Accepted: 03/31/2021] [Indexed: 12/01/2022]
Abstract
INTRODUCTION Recalls of total hip arthroplasty (THA) implants, including metal-on-metal (MoM) THA and dual taper stems, due to increased risk of adverse local tissue reaction (ALTR), represent a challenge for both surgeons and patients. This study aims to analyze the revision surgery outcomes for ALTR in patients with recalled THA implants. METHODS A total of 118 consecutive patients who underwent revision surgery due to ALTR with recalled THA were analyzed. Sub-group analysis was performed for recalled MoM THAs, head-neck modular stems, and dual taper neck-stems. RESULTS At a mean follow-up of 6.6 years, the complication and reoperation rates of the recalled THAs were 32.2% and 25.4% respectively. The most common post-revision complication was dislocation (16%). Revision of modular taper corrosion THA and high-grade intraoperative tissue damage were risk factors associated with post-revision complications. CONCLUSION This study reports high complication and reoperation rates of recalled THAs at mid-term follow-up. The high revision surgery complication rates in both groups suggest the importance of a systematic evaluation of all THA patients with at-risk implants. LEVEL OF EVIDENCE Level III, case control retrospective analysis.
Collapse
Affiliation(s)
- Christian Klemt
- Bioengineering Laboratory, Department of Orthopaedic Surgery, Massachusetts General Hospital, Harvard Medical School, 55 Fruit St, Boston, MA, 02114, USA
| | - Sakkadech Limmahakhun
- Bioengineering Laboratory, Department of Orthopaedic Surgery, Massachusetts General Hospital, Harvard Medical School, 55 Fruit St, Boston, MA, 02114, USA
| | - Georges Bounajem
- Bioengineering Laboratory, Department of Orthopaedic Surgery, Massachusetts General Hospital, Harvard Medical School, 55 Fruit St, Boston, MA, 02114, USA
| | - Christopher M Melnic
- Bioengineering Laboratory, Department of Orthopaedic Surgery, Massachusetts General Hospital, Harvard Medical School, 55 Fruit St, Boston, MA, 02114, USA
| | - Michael J Harvey
- Bioengineering Laboratory, Department of Orthopaedic Surgery, Massachusetts General Hospital, Harvard Medical School, 55 Fruit St, Boston, MA, 02114, USA
| | - Young-Min Kwon
- Bioengineering Laboratory, Department of Orthopaedic Surgery, Massachusetts General Hospital, Harvard Medical School, 55 Fruit St, Boston, MA, 02114, USA.
| |
Collapse
|
4
|
Smith EB. Save the Greater Trochanter: A Novel Modification to the Extended Trochanteric Osteotomy. Arthroplast Today 2022; 16:107-111. [PMID: 35677941 PMCID: PMC9168376 DOI: 10.1016/j.artd.2022.05.004] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/04/2022] [Revised: 05/02/2022] [Accepted: 05/04/2022] [Indexed: 11/26/2022] Open
Abstract
The extended trochanteric osteotomy is the workhorse for removal of well-fixed femoral stems during total hip revision arthroplasty. Despite its reliable performance in exposing the implants for removal and accessing the femoral canal, significant complications can occur. Though these complications are rare, trochanteric nonunion, trochanteric escape, and femoral implant subsidence can have a significant negative impact on gait mechanics and patient outcome. If access to the canal was still possible and the greater trochanter could remain in place, these complications could be minimized or possibly even eliminated. This paper describes a novel technique using a lateral cortical window just distal to the greater trochanter that allows removal of a well-fixed stem and leaves the greater trochanter intact.
Collapse
Affiliation(s)
- Eric B. Smith
- Rothman Orthopaedic Institute at Thomas Jefferson University, Philadelphia, PA, USA
| |
Collapse
|
5
|
Dual Modular Titanium Alloy Femoral Stem Failure Mechanisms and Suggested Clinical Approaches. MATERIALS 2021; 14:ma14113078. [PMID: 34199983 PMCID: PMC8200202 DOI: 10.3390/ma14113078] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 04/29/2021] [Revised: 05/27/2021] [Accepted: 06/02/2021] [Indexed: 12/13/2022]
Abstract
Titanium (Ti) alloys have been proven to be one of the most suitable materials for orthopaedic implants. Dual modular stems have been introduced to primary total hip arthroplasty (THA) to enable better control of the femoral offset, leg length, and hip stability. This systematic review highlights information acquired for dual modular Ti stem complications published in the last 12 years and offers a conclusive discussion of the gathered knowledge. Articles referring to dual modular stem usage, survivorship, and complications in English were searched from 2009 to the present day. A qualitative synthesis of literature was carried out, excluding articles referring solely to other types of junctions or problems with cobalt-chromium alloys in detail. In total, 515 records were identified through database searching and 78 journal articles or conference proceedings were found. The reasons for a modular neck fracture of a Ti alloy are multifactorial. Even though dual modular stems have not shown any clinical benefits for patients and have been associated with worse results regarding durability than monolithic stems, some designs are still marketed worldwide. Orthopaedic surgeons should use Ti6Al4V dual modular stem designs for primary THA in special cases only.
Collapse
|
6
|
Zajc J, Predan J, Gubeljak N, Moličnik A, Fokter SK. Modular femoral neck failure after revision of a total hip arthroplasty: a finite element analysis. EUROPEAN JOURNAL OF ORTHOPAEDIC SURGERY AND TRAUMATOLOGY 2018; 29:717-723. [PMID: 30317469 DOI: 10.1007/s00590-018-2314-8] [Citation(s) in RCA: 12] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/31/2018] [Accepted: 10/07/2018] [Indexed: 12/14/2022]
Abstract
The authors report on a case of modular femoral neck fracture which appeared 21 months after revision of acetabular component. The revision surgery was performed 8 years after the primary total hip arthroplasty due to aseptic loosening of the acetabular component. During acetabular revision, the primary implanted short (S, - 3.5 mm) femoral head was also exchanged with extra-long (XL, + 7.0 mm) femoral head fitting the modular femoral neck with a longer lever arm. Numerical analysis has shown that this has resulted in a 19.9% increase in tensile stress at the neck-stem coupling during normal walking cycle. This could result in microcrack initiation and propagation and finally lead to modular neck failure of the otherwise well-fixed stem. Surgeons should avoid excessive loading of the exchangeable neck (dual-modular) femoral stem designs as the stem-neck couplings are subject to corrosion and are not as reliable as monoblock stems.
Collapse
Affiliation(s)
- Jan Zajc
- Faculty of Medicine, University of Maribor, Maribor, Slovenia
| | - Jožef Predan
- Faculty of Mechanical Engineering, University of Maribor, Maribor, Slovenia
| | - Nenad Gubeljak
- Faculty of Mechanical Engineering, University of Maribor, Maribor, Slovenia
| | - Andrej Moličnik
- Department for Orthopaedic Surgery, University Medical Center Maribor, Ljubljanska 5, 2000, Maribor, Slovenia
| | - Samo K Fokter
- Department for Orthopaedic Surgery, University Medical Center Maribor, Ljubljanska 5, 2000, Maribor, Slovenia.
| |
Collapse
|
7
|
Mah D, Pelletier MH, Lovric V, Walsh WR. Corrosion of 3D-Printed Orthopaedic Implant Materials. Ann Biomed Eng 2018; 47:162-173. [DOI: 10.1007/s10439-018-02111-1] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/29/2018] [Accepted: 07/29/2018] [Indexed: 02/08/2023]
|
8
|
Krull A, Morlock MM, Bishop NE. Factors influencing taper failure of modular revision hip stems. Med Eng Phys 2018; 54:65-73. [PMID: 29500122 DOI: 10.1016/j.medengphy.2018.02.001] [Citation(s) in RCA: 18] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/29/2017] [Revised: 01/19/2018] [Accepted: 02/11/2018] [Indexed: 10/17/2022]
Abstract
Stem modularity of revision hip implant systems offers the advantage of the restoration of individual patient geometry but introduces additional interfaces, which are subjected to repetitive bending loading and have a propensity for fretting corrosion. The male stem taper is the weakest part of the modular junction due to its reduced cross section compared to the outside diameter of the stem. Taper fractures can be the consequence of overloading in combination with corrosion. The purpose of this study was to assess the influence of implant design factors, patient factors, and surgical factors on the risk of taper failure of the modular junction of revision stems. An analytical bending model was used to estimate the strength of the taper connection for pristine, fatigued and corroded conditions. Additionally, a finite element contact model of the taper connection was developed to assess the relative motion and potential for surface damage at the taper interface under physiological loading for varyied assembly and design parameters. Increasing the male taper diameter was shown to be the most effective means for increasing taper strength but would require a concurrent increase in the outer implant diameter to limit a greater risk of total surface damage for a thinner female taper wall. Increasing the assembly force decreases the total surface damage but not local magnitudes, which are probably responsible for crack initiation. It is suggested that in unfavourable loading conditions a monobloc implant system will reduce the risk of failure.
Collapse
Affiliation(s)
- A Krull
- TUHH - Hamburg University of Technology, Institute of Biomechanics, Denickestrasse 15, 21073 Hamburg, Germany.
| | - M M Morlock
- TUHH - Hamburg University of Technology, Institute of Biomechanics, Denickestrasse 15, 21073 Hamburg, Germany
| | - N E Bishop
- HAW - Hamburg University of Applied Science, Fakulty of Life Sciences, Department of Biomedical Engineering, Ulmenliet 20, 21033 Hamburg, Germany
| |
Collapse
|
9
|
Matharu GS, Judge A, Murray DW, Pandit HG. Outcomes following revision surgery performed for adverse reactions to metal debris in non-metal-on-metal hip arthroplasty patients: Analysis of 185 revisions from the National Joint Registry for England and Wales. Bone Joint Res 2017; 6:405-413. [PMID: 28710154 PMCID: PMC5539305 DOI: 10.1302/2046-3758.67.bjr-2017-0017.r2] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/25/2017] [Accepted: 04/11/2016] [Indexed: 01/10/2023] Open
Abstract
OBJECTIVES Few studies have assessed outcomes following non-metal-on-metal hip arthroplasty (non-MoMHA) revision surgery performed for adverse reactions to metal debris (ARMD). We assessed outcomes following non-MoMHA revision surgery performed for ARMD, and identified predictors of re-revision. METHODS We performed a retrospective observational study using data from the National Joint Registry for England and Wales. All non-MoMHAs undergoing revision surgery for ARMD between 2008 and 2014 were included (185 hips in 185 patients). Outcome measures following ARMD revision were intra-operative complications, mortality and re-revision surgery. Predictors of re-revision were identified using Cox regression. RESULTS Intra-operative complications occurred in 6.0% (n = 11) of the 185 cases. The cumulative four-year patient survival rate was 98.2% (95% CI 92.9 to 99.5). Re-revision surgery was performed in 13.5% (n = 25) of hips at a mean time of 1.2 years (0.1 to 3.1 years) following ARMD revision. Infection (32%; n = 8), dislocation/subluxation (24%; n = 6), and aseptic loosening (24%; n = 6) were the most common re-revision indications. The cumulative four-year implant survival rate was 83.8% (95% CI 76.7 to 88.9). Multivariable analysis identified three predictors of re-revision: multiple revision indications (hazard ratio (HR) = 2.78; 95% CI 1.03 to 7.49; p = 0.043); selective component revisions (HR = 5.76; 95% CI 1.28 to 25.9; p = 0.022); and ceramic-on-polyethylene revision bearings (HR = 3.08; 95% CI 1.01 to 9.36; p = 0.047). CONCLUSIONS Non-MoMHAs revised for ARMD have a high short-term risk of re-revision, with important predictors of future re-revision including selective component revision, multiple revision indications, and ceramic-on-polyethylene revision bearings. Our findings may help counsel patients about the risks of ARMD revision, and guide reconstructive decisions. Future studies attempting to validate the predictors identified should also assess the effects of implant design (metallurgy and modularity), given that this was an important study limitation potentially influencing the reported prognostic factors.Cite this article: G. S. Matharu, A. Judge, D. W. Murray, H. G. Pandit. Outcomes following revision surgery performed for adverse reactions to metal debris in non-metal-on-metal hip arthroplasty patients: Analysis of 185 revisions from the National Joint Registry for England and Wales. Bone Joint Res 2017;6:405-413. DOI: 10.1302/2046-3758.67.BJR-2017-0017.R2.
Collapse
Affiliation(s)
- G S Matharu
- Nuffield Department of Orthopaedics, Rheumatology and Musculoskeletal Sciences, University of Oxford, Nuffield Orthopaedic Centre, Oxford OX3 7LD, UK
| | - A Judge
- Nuffield Department of Orthopaedics, Rheumatology and Musculoskeletal Sciences; University of Oxford, Nuffield Orthopaedic Centre, Oxford OX3 7LD, and MRC Lifecourse Epidemiology Unit, Southampton General Hospital, University of Southampton, Southampton SO16 6YD, UK
| | - D W Murray
- Nuffield Department of Orthopaedics, Rheumatology and Musculoskeletal Sciences, University of Oxford, Nuffield Orthopaedic Centre, Oxford OX3 7LD, UK
| | - H G Pandit
- Leeds Institute of Rheumatic and Musculoskeletal Medicine; University of Leeds and Leeds Teaching Hospitals NHS Trust, Chapel Allerton Hospital, Chapeltown Rd, Leeds LS7 4SA, and Nuffield Department of Orthopaedics, Rheumatology and Musculoskeletal Sciences, University of Oxford, Nuffield Orthopaedic Centre, Oxford OX3 7LD, UK
| |
Collapse
|