Wang Y, Ma D, Feng Z, Yu W, Chen Y, Zhong S, Ouyang J, Qian L. A novel method for in vivo measurement of dynamic ischiofemoral space based on MRI and motion capture. Front Bioeng Biotechnol 2023; 11:1067600. [PMID: 36761299 PMCID: PMC9905814 DOI: 10.3389/fbioe.2023.1067600] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/12/2022] [Accepted: 01/16/2023] [Indexed: 01/26/2023] Open
Abstract
Purpose: To use a novel in vivo method to simulate a moving hip model. Then, measure the dynamic bone-to-bone distance, and analyze the ischiofemoral space (IFS) of patients diagnosed with ischiofemoral impingement syndrome (IFI) during dynamic activities. Methods: Nine healthy subjects and 9 patients with IFI were recruited to collect MRI images and motion capture data. The motion trail of the hip during motion capture was matched to a personalized 3D hip model reconstructed from MRI images to get a dynamic bone model. This personalized dynamic in vivo method was then used to simulate the bone motion in dynamic activities. Validation was conducted on a 3D-printed sphere by comparing the calculated data using this novel method with the actual measured moving data using motion capture. Moreover, the novel method was used to analyze the in vivo dynamic IFS between healthy subjects and IFI patients during normal and long stride walking. Results: The validation results show that the root mean square error (RMSE) of slide and rotation was 1.42 mm/1.84° and 1.58 mm/2.19°, respectively. During normal walking, the in vivo dynamic IFS was significantly larger in healthy hips (ranged between 15.09 and 50.24 mm) compared with affected hips (between 10.16 and 39.74 mm) in 40.27%-83.81% of the gait cycle (p = 0.027). During long stride walking, the in vivo dynamic IFS was also significantly larger in healthy hips (ranged between 13.02 and 51.99 mm) than affected hips (between 9.63 and 44.22 mm) in 0%-5.85% of the gait cycle (p = 0.049). Additionally, the IFS of normal walking was significantly smaller than long stride walking during 0%-14.05% and 85.07%-100% of the gait cycle (p = 0.033, 0.033) in healthy hips. However, there was no difference between the two methods of walking among the patients. Conclusions: This study established a novel in vivo method to measure the dynamic bone-to-bone distance and was well validated. This method was used to measure the IFS of patients diagnosed with IFI, and the results showed that the IFS of patients is smaller compared with healthy subjects, whether in normal or long stride walking. Meanwhile, IFI eliminated the difference between normal and long stride walking.
Collapse
Affiliation(s)
- Yining Wang
- Guangdong Provincial Key Laboratory of Digital Medicine and Biomechanics and Guangdong Engineering Research Center for Translation of Medical 3D Printing Application and National Virtual and Reality Experimental Education Center for Medical Morphology (Southern Medical University) and National Experimental Education Demonstration Center for Basic Medical Sciences (Southern Medical University) and National Key Discipline of Human Anatomy, School of Basic Medical Sciences, Southern Medical University, Guangzhou, China
| | - Dong Ma
- Guangdong Provincial Key Laboratory of Digital Medicine and Biomechanics and Guangdong Engineering Research Center for Translation of Medical 3D Printing Application and National Virtual and Reality Experimental Education Center for Medical Morphology (Southern Medical University) and National Experimental Education Demonstration Center for Basic Medical Sciences (Southern Medical University) and National Key Discipline of Human Anatomy, School of Basic Medical Sciences, Southern Medical University, Guangzhou, China
| | - Zhengkuan Feng
- Guangdong Provincial Key Laboratory of Digital Medicine and Biomechanics and Guangdong Engineering Research Center for Translation of Medical 3D Printing Application and National Virtual and Reality Experimental Education Center for Medical Morphology (Southern Medical University) and National Experimental Education Demonstration Center for Basic Medical Sciences (Southern Medical University) and National Key Discipline of Human Anatomy, School of Basic Medical Sciences, Southern Medical University, Guangzhou, China
| | - Wanqi Yu
- Guangdong Provincial Key Laboratory of Digital Medicine and Biomechanics and Guangdong Engineering Research Center for Translation of Medical 3D Printing Application and National Virtual and Reality Experimental Education Center for Medical Morphology (Southern Medical University) and National Experimental Education Demonstration Center for Basic Medical Sciences (Southern Medical University) and National Key Discipline of Human Anatomy, School of Basic Medical Sciences, Southern Medical University, Guangzhou, China
| | - Yanjun Chen
- Department of Medical Imaging, The Third Affiliated Hospital, Southern Medical University, Guangzhou, China
| | - Shizhen Zhong
- Guangdong Provincial Key Laboratory of Digital Medicine and Biomechanics and Guangdong Engineering Research Center for Translation of Medical 3D Printing Application and National Virtual and Reality Experimental Education Center for Medical Morphology (Southern Medical University) and National Experimental Education Demonstration Center for Basic Medical Sciences (Southern Medical University) and National Key Discipline of Human Anatomy, School of Basic Medical Sciences, Southern Medical University, Guangzhou, China,*Correspondence: Lei Qian, ; Jun Ouyang, ; Shizhen Zhong,
| | - Jun Ouyang
- Guangdong Provincial Key Laboratory of Digital Medicine and Biomechanics and Guangdong Engineering Research Center for Translation of Medical 3D Printing Application and National Virtual and Reality Experimental Education Center for Medical Morphology (Southern Medical University) and National Experimental Education Demonstration Center for Basic Medical Sciences (Southern Medical University) and National Key Discipline of Human Anatomy, School of Basic Medical Sciences, Southern Medical University, Guangzhou, China,*Correspondence: Lei Qian, ; Jun Ouyang, ; Shizhen Zhong,
| | - Lei Qian
- Guangdong Provincial Key Laboratory of Digital Medicine and Biomechanics and Guangdong Engineering Research Center for Translation of Medical 3D Printing Application and National Virtual and Reality Experimental Education Center for Medical Morphology (Southern Medical University) and National Experimental Education Demonstration Center for Basic Medical Sciences (Southern Medical University) and National Key Discipline of Human Anatomy, School of Basic Medical Sciences, Southern Medical University, Guangzhou, China,*Correspondence: Lei Qian, ; Jun Ouyang, ; Shizhen Zhong,
| |
Collapse
|
2
|
Kefala V, Ali AA, Hamilton LD, Mannen EM, Shelburne KB. Effects of Weight-Bearing on Tibiofemoral, Patellofemoral, and Patellar Tendon Kinematics in Older Adults. Front Bioeng Biotechnol 2022; 10:820196. [PMID: 35497367 PMCID: PMC9048742 DOI: 10.3389/fbioe.2022.820196] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/22/2021] [Accepted: 03/08/2022] [Indexed: 11/26/2022] Open
Abstract
Quantification of natural knee kinematics is essential for the assessment of joint function in the diagnosis of pathologies. Combined measurements of tibiofemoral and patellofemoral joint kinematics are necessary because knee pathologies, such as progression of osteoarthritis and patellar instability, are a frequent concern in both articulations. Combined measurement of tibiofemoral and patellofemoral kinematics also enables calculation of important quantities, specifically patellar tendon angle, which partly determines the loading vector at the tibiofemoral joint and patellar tendon moment arm. The goals of this research were to measure the differences in tibiofemoral and patellofemoral kinematics, patellar tendon angle (PTA), and patellar tendon moment arm (PTMA) that occur during non-weight-bearing and weight-bearing activities in older adults. METHODS High-speed stereo radiography was used to measure the kinematics of the tibiofemoral and patellofemoral joints in subjects as they performed seated, non-weight-bearing knee extension and two weight-bearing activities: lunge and chair rise. PTA and PTMA were extracted from the subject's patellofemoral and tibiofemoral kinematics. Kinematics and the root mean square difference (RMSD) between non-weight-bearing and weight-bearing activities were compared across subjects and activities. RESULTS Internal rotation increased with weight-bearing (mean RMSD from knee extension was 4.2 ± 2.4° for lunge and 3.6 ± 1.8° for chair rise), and anterior translation was also greater (mean RMSD from knee extension was 2.2 ± 1.2 mm for lunge and 2.3 ± 1.4 mm for chair rise). Patellar tilt and medial-lateral translation changed from non-weight-bearing to weight-bearing. Changes of the patellar tendon from non-weight-bearing to weight-bearing were significant only for PTMA. CONCLUSIONS While weight-bearing elicited changes in knee kinematics, in most degrees of freedoms, these differences were exceeded by intersubject differences. These results provide comparative kinematics for the evaluation of knee pathology and treatment in older adults.
Collapse
Affiliation(s)
- Vasiliki Kefala
- Department of Mechanical and Materials Engineering, University of Denver, Denver, CO, United States
| | - Azhar A. Ali
- Department of Mechanical and Materials Engineering, University of Denver, Denver, CO, United States
- Stryker Orthopedics, Kalamazoo, MI, United States
| | - Landon D. Hamilton
- Department of Mechanical and Materials Engineering, University of Denver, Denver, CO, United States
| | - Erin M. Mannen
- Department of Mechanical and Materials Engineering, University of Denver, Denver, CO, United States
- Department of Mechanical and Biomedical Engineering, Boise State University, Boise, ID, United States
| | - Kevin B. Shelburne
- Department of Mechanical and Materials Engineering, University of Denver, Denver, CO, United States
| |
Collapse
|
3
|
Kefala V, Ali AA, Mannen EM, Shelburne KB. Patellofemoral kinematics in healthy older adults during gait activities. Hum Mov Sci 2020; 75:102746. [PMID: 33378727 DOI: 10.1016/j.humov.2020.102746] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/24/2020] [Revised: 12/02/2020] [Accepted: 12/08/2020] [Indexed: 11/28/2022]
Abstract
The patellofemoral (PF) joint is susceptible to many pathologies resulting from acute injury, chronic disease and complications following surgical treatment of the knee. The objectives of this study were to describe case series measurements of patellar motion in healthy older adults as they performed three gait activities, determine patellar tendon angle and moment arm, and show if these quantities were activity dependent. A stereo radiography system was utilized to obtain the 3D PF kinematics of seventeen healthy people over 55 years of age (8F/9M, 66 ± 7.9 years old, 75.7 ± 20.5 kg) as they performed level walking, a step down, and a pivot turn. For a similar portion of the gait cycle, patellar flexion (6.2° ± 5.8) and average range of motion (ROM) (11.0° ± 5.9°) for walking with a step down was greater compared to the other gait activities (gait ROM 6.9° ± 4.3°, pivot ROM 5.7° ± 3.3°), while the average range of motion for patella tilt was greater during walking with a pivot turn (8.6° ± 3.9°). However, each subject displayed distinct PF kinematic trends during all activities with a few notable exceptions. Importantly, the knee extensor mechanism characteristics of patellar tendon angle and moment arm showed considerable variation across subjects but were largely unaltered by changing activities. The variation between subjects and the different behavior of the patella during the step down and pivot emphasized the need for analysis of a range of activities to reveal individual response to pathology and treatment in patellar maltracking and osteoarthritis.
Collapse
Affiliation(s)
- Vasiliki Kefala
- Center for Orthopaedic Biomechanics, Dept. of Mechanical and Materials Engineering, The University of Denver, CO, USA
| | | | - Erin M Mannen
- Dept. of Mechanical and Biomedical Engineering Boise State University, Boise, ID, USA
| | - Kevin B Shelburne
- Center for Orthopaedic Biomechanics, Dept. of Mechanical and Materials Engineering, The University of Denver, CO, USA.
| |
Collapse
|
4
|
A robust and semi-automatic quantitative measurement of patellofemoral instability based on four dimensional computed tomography. Med Eng Phys 2020; 78:29-38. [PMID: 32115353 DOI: 10.1016/j.medengphy.2020.01.012] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/10/2018] [Revised: 01/02/2020] [Accepted: 01/23/2020] [Indexed: 11/21/2022]
Abstract
Patellofemoral instability is a motion related disease, featured as the patella dislocating from the trochlear groove. Four dimensional computed tomography (4DCT) enables full assessment of the patellofemoral movement. Nevertheless, the quantitative measurements of patellofemoral instability are still under research and currently of limited practical use. The aim of this study is to develop a robust and semi-automatic workflow to quantitatively describe the patellofemoral movement in a patient group of eight suffering from patellofemoral instability. The initial results show agreement with manual observations of the tibial tubercle - trochlear groove (TT-TG) distance in routine practice, and the possibility to evaluate both TT-TG distance and patellar centre - trochlear groove (PC-TG) distance dynamically during active flexion-extension-flexion movement of the knee.
Collapse
|
5
|
Research Methods and Progress of Patellofemoral Joint Kinematics: A Review. JOURNAL OF HEALTHCARE ENGINEERING 2019; 2019:9159267. [PMID: 31019669 PMCID: PMC6451817 DOI: 10.1155/2019/9159267] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 10/01/2018] [Revised: 12/20/2018] [Accepted: 01/28/2019] [Indexed: 01/14/2023]
Abstract
Patellofemoral pain syndrome has a high morbidity, and its pathology is closely associated with patellofemoral joint kinematics. A series of in vivo and in vitro studies have been conducted to explore patellofemoral kinematics, and the findings are relevant to the diagnosis, classification, and management of patellofemoral diseases and even the whole knee joint. However, no definite conclusion on normal patellofemoral kinematics has been established. In this study, the measurement methodologies of patellofemoral kinematics (including data collection methods, loading conditions, and coordinate system) as well as their advantages and limitations were reviewed. Motion characteristics of the patella were analyzed. During knee flexion, the patellar flexion angle lagged by 30–40% compared to the tibiofemoral joint flexion. The patella tilts, rotates, and shifts medially in the initial stage of knee flexion and subsequently tilts, rotates, and shifts laterally. The finite patellar helical axis fluctuates near the femoral transepicondylar axis or posterior condylar axis. Moreover, factors affecting kinematics, such as morphology of the trochlear groove, soft tissue balance, and tibiofemoral motion, were analyzed. At the initial period of flexion, soft tissues play a vital role in adjusting patellar tracking, and during further flexion, the status of the patella is determined by the morphology of the trochlear groove and patellar facet. Our findings could increase our understanding of patellofemoral kinematics and can help to guide the operation plan for patients with patellofemoral pain syndrome.
Collapse
|
6
|
In vivo dynamic acromiohumeral distance in shoulders with rotator cuff tears. Clin Biomech (Bristol, Avon) 2018; 60:95-99. [PMID: 30340151 DOI: 10.1016/j.clinbiomech.2018.07.017] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/15/2017] [Revised: 07/21/2018] [Accepted: 07/25/2018] [Indexed: 02/07/2023]
Abstract
BACKGROUND There are no previous studies on the acromiohumeral distance in shoulders with large-to-massive full-thickness rotator cuff tears. In this study, the acromiohumeral distance in rotator cuff tear and healthy shoulders was measured using 3D-to-2D model-to-image registration techniques. METHODS The dynamic glenohumeral kinematics during scapular plane abduction and axial rotation were analyzed in 11 rotator cuff tear patients and 10 healthy control subjects. Periodic radiographic images of scapular plane abduction and axial rotation were taken using a flat-panel radiograph image detector. Movements of the shoulder joint were assessed using radiographic images and computed tomography-derived digitally reconstructed radiographs. The acromiohumeral distance was defined as the shortest 3D distance between the acromion and the proximal humerus. FINDINGS For scapular plane abduction, the rotator cuff tear group had significantly smaller acromiohumeral distance than the control group at 15°, 30°, 45°, 60°, 75°, 135°, and 150° of humeral abduction (P < 0.05 at each measured angle). For axial rotation in the adducted position, the rotator cuff tear group had significantly smaller acromiohumeral distance than the control group at each point between -20° and 40° of glenohumeral external rotation (P < 0.05 at each measured angle). INTERPRETATION The minimum measured acromiohumeral distance was 0.9 mm in the rotator cuff tear shoulders and 2.1 mm in the healthy shoulders at 90° of scapular plane abduction. The findings are of clinical relevance because quantitative evaluation of the dynamic acromiohumeral distances in rotator cuff tear and healthy shoulders might provide important insight into subacromial impingement.
Collapse
|
7
|
In vivo validation of patellofemoral kinematics during overground gait and stair ascent. Gait Posture 2018; 64:191-197. [PMID: 29929162 PMCID: PMC6084796 DOI: 10.1016/j.gaitpost.2018.06.028] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/27/2018] [Revised: 06/12/2018] [Accepted: 06/13/2018] [Indexed: 02/02/2023]
Abstract
BACKGROUND The patellofemoral (PF) joint is a common site for non-specific anterior knee pain. The pathophysiology of patellofemoral pain may be related to abnormal motion of the patella relative to the femur, leading to increased stress at the patellofemoral joint. Patellofemoral motion cannot be accurately measured using conventional motion capture. RESEARCH QUESTION The aim of this study was to determine the accuracy of a biplane radiography system for measuring in vivo PF motion during walking and stair ascent. METHODS Four subjects had three 1.0 mm diameter tantalum beads implanted into the patella. Participants performed three trials each of over ground walking and stair ascent while biplane radiographs were collected at 100 Hz. Patella motion was tracked using radiostereophotogrammetric analysis (RSA) as a "gold standard", and compared to a volumetric CT model-based tracking algorithm that matched digitally reconstructed radiographs to the original biplane radiographs. RESULTS The average RMS difference between the RSA and model-based tracking was 0.41 mm and 1.97° when there was no obstruction from the contralateral leg. These differences increased by 34% and 40%, respectively, when the patella was at least partially obstructed by the contralateral leg. The average RMS difference in patellofemoral joint space between tracking methods was 0.9 mm or less. SIGNIFICANCE Previous validations of biplane radiographic systems have estimated tracking accuracy by moving cadaveric knees through simulated motions. These validations were unable to replicate in vivo kinematics, including patella motion due to muscle activation, and failed to assess the imaging and tracking challenges related to contralateral limb obstruction. By replicating the muscle contraction, movement velocity, joint range of motion, and obstruction of the patella by the contralateral limb, the present study provides a realistic estimate of patellofemoral tracking accuracy for future in vivo studies.
Collapse
|
8
|
Kozono N, Okada T, Takeuchi N, Hamai S, Higaki H, Shimoto T, Ikebe S, Gondo H, Nakanishi Y, Senju T, Nakashima Y. Dynamic kinematics of the glenohumeral joint in shoulders with rotator cuff tears. J Orthop Surg Res 2018; 13:9. [PMID: 29325577 PMCID: PMC5765635 DOI: 10.1186/s13018-017-0709-6] [Citation(s) in RCA: 19] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/15/2017] [Accepted: 12/26/2017] [Indexed: 11/29/2022] Open
Abstract
Background No clear trend has emerged from the literature regarding three-dimensional (3D) translations of the humerus relative to the scapula in shoulders with rotator cuff tears (RCTs). The purpose of this study was to evaluate the kinematics of RCT shoulders using 3D-to-two-dimensional (2D) model-to-image registration techniques. Methods Dynamic glenohumeral kinematics during scapular plane abduction and axial rotation were analyzed in 11 RCT patients and 10 healthy control subjects. We measured the 3D kinematic parameters of glenohumeral joints using X-ray images and CT-derived digitally reconstructed radiographs. Results For scapular plane abduction, the humeral head center was positioned significantly more medially in shoulders with RCTs than in controls at 135° of humeral abduction (p = 0.02; RCTs versus controls: − 0.9 ± 1.6 versus 0.3 ± 1.3 mm). There was no significant difference in the superior/inferior translation of the humeral head center (p = 0.99). For axial rotation in adducted position, the humeral head center was positioned significantly more anteriorly in shoulders with RCTs than in controls at − 30° of glenohumeral external rotation (p < 0.0001; RCTs versus controls: 3.0 ± 1.7 versus 0.3 ± 1.5 mm). Conclusions This study revealed the kinematics of shoulders with large to massive full-thickness RCTs: the humeral head center showed a medial shift at the late phase of scapular plane full abduction, and an anterior shift at the internal rotation position during full axial rotation. The kinematic data in this study, which describe the patterns of movement of shoulders with large to massive full-thickness RCTs, provide valuable information for future studies investigating glenohumeral translations in other pathological conditions of the shoulder. For clinical relevance, quantitative assessment of the dynamic kinematics of shoulders with RCTs might be a therapeutic indicator for achieving functional restoration.
Collapse
Affiliation(s)
- Naoya Kozono
- Department of Orthopaedic Surgery, Graduate School of Medical Sciences, Kyushu University, 3-1-1 Maidashi, Higashi-ku, Fukuoka City, Fukuoka, 812-8582, Japan
| | - Takamitsu Okada
- Department of Orthopaedic Surgery, Graduate School of Medical Sciences, Kyushu University, 3-1-1 Maidashi, Higashi-ku, Fukuoka City, Fukuoka, 812-8582, Japan.
| | - Naohide Takeuchi
- Department of Orthopaedic Surgery, Graduate School of Medical Sciences, Kyushu University, 3-1-1 Maidashi, Higashi-ku, Fukuoka City, Fukuoka, 812-8582, Japan
| | - Satoshi Hamai
- Department of Orthopaedic Surgery, Graduate School of Medical Sciences, Kyushu University, 3-1-1 Maidashi, Higashi-ku, Fukuoka City, Fukuoka, 812-8582, Japan
| | - Hidehiko Higaki
- Department of Life Science, Faculty of Life Science, Kyushu Sangyo University, 2-3-1, Matsukadai, Higashi-ku, Fukuoka City, Fukuoka, 813-8503, Japan
| | - Takeshi Shimoto
- Department of Information and System Engineering, Faculty of Information Engineering, Fukuoka Institute of Technology, 3-30-1 Wajiro-higashi, Higashi-ku, Fukuoka City, Fukuoka, 811-0295, Japan
| | - Satoru Ikebe
- Department of Creative Engineering, National Institute of Technology, Kitakyushu College, 5-20-1 Shii, Kokuraminami-ku, Kitakyushu City, Fukuoka, 802-0985, Japan
| | - Hirotaka Gondo
- Department of Life Science, Faculty of Life Science, Kyushu Sangyo University, 2-3-1, Matsukadai, Higashi-ku, Fukuoka City, Fukuoka, 813-8503, Japan
| | - Yoshitaka Nakanishi
- Department of Orthopaedic Surgery, Graduate School of Medical Sciences, Kyushu University, 3-1-1 Maidashi, Higashi-ku, Fukuoka City, Fukuoka, 812-8582, Japan
| | - Takahiro Senju
- Department of Orthopaedic Surgery, Graduate School of Medical Sciences, Kyushu University, 3-1-1 Maidashi, Higashi-ku, Fukuoka City, Fukuoka, 812-8582, Japan
| | - Yasuharu Nakashima
- Department of Orthopaedic Surgery, Graduate School of Medical Sciences, Kyushu University, 3-1-1 Maidashi, Higashi-ku, Fukuoka City, Fukuoka, 812-8582, Japan
| |
Collapse
|
9
|
Kozono N, Okada T, Takeuchi N, Hamai S, Higaki H, Ikebe S, Shimoto T, Miake G, Nakanishi Y, Iwamoto Y. In vivo kinematic analysis of the glenohumeral joint during dynamic full axial rotation and scapular plane full abduction in healthy shoulders. Knee Surg Sports Traumatol Arthrosc 2017; 25:2032-2040. [PMID: 27511218 DOI: 10.1007/s00167-016-4263-2] [Citation(s) in RCA: 22] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/13/2016] [Accepted: 08/02/2016] [Indexed: 11/28/2022]
Abstract
PURPOSE The purpose of this study was to evaluate the kinematics of healthy shoulders during dynamic full axial rotation and scapular plane full abduction using three-dimensional (3D)-to-two-dimensional (2D) model-to-image registration techniques. METHODS Dynamic glenohumeral kinematics during axial rotation and scapular plane abduction were analysed in 10 healthy participants. Continuous radiographic images of axial rotation and scapular plane abduction were taken using a flat panel radiographic detector. The participants received a computed tomography scan to generate virtual digitally reconstructed radiographs. The density-based digitally reconstructed radiographs were then compared with the serial radiographic images acquired using image correlations. These 3D-to-2D model-to-image registration techniques determined the 3D positions and orientations of the humerus and scapula during dynamic full axial rotation and scapular plane full abduction. RESULTS The humeral head centre translated an average of 2.5 ± 3.1 mm posteriorly, and 1.4 ± 1.0 mm superiorly in the early phase, then an average of 2.0 ± 0.8 mm inferiorly in the late phase during external rotation motion. The glenohumeral external rotation angle had a significant effect on the anterior/posterior (A/P) and superior/inferior (S/I) translation of the humeral head centre (both p < 0.05). 33.6 ± 15.6° of glenohumeral external rotation occurred during scapular plane abduction. The humeral head centre translated an average of 0.6 ± 0.9 mm superiorly in the early phase, then 1.7 ± 2.6 mm inferiorly in the late phase, and translated an average of 0.4 ± 0.5 mm medially in the early phase, then 1.6 ± 1.0 mm laterally in the late phase during scapular plane abduction. The humeral abduction angle had a significant effect on the S/I and lateral/medial (L/M) translation of the humeral head centre (both p < 0.05). CONCLUSION This study investigated 3D translations of the humerus relative to the scapula: during scapular plane full abduction, the humerus rotated 33.6° externally relative to the scapula, and during external rotation motion in the adducted position, the humeral head centre translated an average of 2.5 mm posteriorly. Kinematic data will provide important insights into evaluating the kinematics of pathological shoulders. For clinical relevance, quantitative assessment of dynamic healthy shoulder kinematics might be a physiological indicator for the assessment of pathological shoulders.
Collapse
Affiliation(s)
- Naoya Kozono
- Department of Orthopaedic Surgery, Graduate School of Medical Sciences, Kyushu University, 3-1-1 Maidashi, Higashi-ku, Fukuoka City, Fukuoka, 812-8582, Japan
| | - Takamitsu Okada
- Department of Orthopaedic Surgery, Graduate School of Medical Sciences, Kyushu University, 3-1-1 Maidashi, Higashi-ku, Fukuoka City, Fukuoka, 812-8582, Japan.
| | - Naohide Takeuchi
- Department of Orthopaedic Surgery, Graduate School of Medical Sciences, Kyushu University, 3-1-1 Maidashi, Higashi-ku, Fukuoka City, Fukuoka, 812-8582, Japan
| | - Satoshi Hamai
- Department of Orthopaedic Surgery, Graduate School of Medical Sciences, Kyushu University, 3-1-1 Maidashi, Higashi-ku, Fukuoka City, Fukuoka, 812-8582, Japan
| | - Hidehiko Higaki
- Department of Biorobotics, Faculty of Engineering, Kyushu Sangyo University, 2-3-1, Matsukadai, Higashi-ku, Fukuoka City, Fukuoka, 813-8503, Japan
| | - Satoru Ikebe
- Department of Biorobotics, Faculty of Engineering, Kyushu Sangyo University, 2-3-1, Matsukadai, Higashi-ku, Fukuoka City, Fukuoka, 813-8503, Japan
| | - Takeshi Shimoto
- Department of Information and System Engineering, Faculty of Information Engineering, Fukuoka Institute of Technology, 3-30-1 Wajiro-higashi, Higashi-ku, Fukuoka City, Fukuoka, 811-0295, Japan
| | - Go Miake
- Department of Orthopaedic Surgery, Graduate School of Medical Sciences, Kyushu University, 3-1-1 Maidashi, Higashi-ku, Fukuoka City, Fukuoka, 812-8582, Japan
| | - Yoshitaka Nakanishi
- Department of Orthopaedic Surgery, Graduate School of Medical Sciences, Kyushu University, 3-1-1 Maidashi, Higashi-ku, Fukuoka City, Fukuoka, 812-8582, Japan
| | - Yukihide Iwamoto
- Department of Orthopaedic Surgery, Graduate School of Medical Sciences, Kyushu University, 3-1-1 Maidashi, Higashi-ku, Fukuoka City, Fukuoka, 812-8582, Japan
| |
Collapse
|
10
|
Accuracy of mobile biplane X-ray imaging in measuring 6-degree-of-freedom patellofemoral kinematics during overground gait. J Biomech 2017; 57:152-156. [DOI: 10.1016/j.jbiomech.2017.04.009] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/09/2016] [Revised: 01/16/2017] [Accepted: 04/09/2017] [Indexed: 11/19/2022]
|
11
|
Quantitative analysis of the patellofemoral motion pattern using semi-automatic processing of 4D CT data. Int J Comput Assist Radiol Surg 2016; 11:1731-41. [DOI: 10.1007/s11548-016-1357-8] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/01/2015] [Accepted: 02/02/2016] [Indexed: 01/31/2023]
|
12
|
Kinematic analysis of healthy hips during weight-bearing activities by 3D-to-2D model-to-image registration technique. BIOMED RESEARCH INTERNATIONAL 2014; 2014:457573. [PMID: 25506056 PMCID: PMC4258366 DOI: 10.1155/2014/457573] [Citation(s) in RCA: 29] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 07/11/2014] [Accepted: 09/19/2014] [Indexed: 12/28/2022]
Abstract
Dynamic hip kinematics during weight-bearing activities were analyzed for six healthy subjects. Continuous X-ray images of gait, chair-rising, squatting, and twisting were taken using a flat panel X-ray detector. Digitally reconstructed radiographic images were used for 3D-to-2D model-to-image registration technique. The root-mean-square errors associated with tracking the pelvis and femur were less than 0.3 mm and 0.3° for translations and rotations. For gait, chair-rising, and squatting, the maximum hip flexion angles averaged 29.6°, 81.3°, and 102.4°, respectively. The pelvis was tilted anteriorly around 4.4° on average during full gait cycle. For chair-rising and squatting, the maximum absolute value of anterior/posterior pelvic tilt averaged 12.4°/11.7° and 10.7°/10.8°, respectively. Hip flexion peaked on the way of movement due to further anterior pelvic tilt during both chair-rising and squatting. For twisting, the maximum absolute value of hip internal/external rotation averaged 29.2°/30.7°. This study revealed activity dependent kinematics of healthy hip joints with coordinated pelvic and femoral dynamic movements. Kinematics' data during activities of daily living may provide important insight as to the evaluating kinematics of pathological and reconstructed hips.
Collapse
|
13
|
Ishimaru M, Shiraishi Y, Ikebe S, Higaki H, Hino K, Onishi Y, Miura H. Three-dimensional motion analysis of the patellar component in total knee arthroplasty by the image matching method using image correlations. J Orthop Res 2014; 32:619-26. [PMID: 24522960 DOI: 10.1002/jor.22596] [Citation(s) in RCA: 17] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/26/2013] [Accepted: 01/17/2014] [Indexed: 02/04/2023]
Abstract
In total knee arthroplasty (TKA), the patella is significantly associated with range of motion and gait performance. Currently, no highly accurate methods are available that can measure the 3D in vivo behavior of the TKA patellar component, as the component is made of x-ray-permeable ultra-high molecular weight polyethylene. Previously, we developed a computer simulation that matches CT scan and unidirectional radiographic images using image correlations, and applied it to kinematic studies of natural and TKA knees. The examination of the measurement accuracy for the patellar bone of a fresh-frozen pig knee joint yielded a root mean square error of 0.2 mm in translation and 0.2° in rotation. In this study, we recruited four patients who had a TKA and investigated 3D movements of the patellar component during squatting. We could visualize the patellar component using the position of the holes drilled for the component peg, and estimated and visualized the contact points between the patellar and femoral components. The principles and the utility of the simulation method are reported. This analytical method is useful for evaluating the pathologies and post-surgical conditions of the knee and other joints.
Collapse
Affiliation(s)
- Masami Ishimaru
- Department of Bone and Joint Surgery, Graduate School of Medicine, Ehime University, Shitsukawa, Toon, Ehime, 791-0295, Japan
| | | | | | | | | | | | | |
Collapse
|
14
|
Pillet H, Sangeux M, Hausselle J, El Rachkidi R, Skalli W. A reference method for the evaluation of femoral head joint center location technique based on external markers. Gait Posture 2013; 39:655-8. [PMID: 24055179 DOI: 10.1016/j.gaitpost.2013.08.020] [Citation(s) in RCA: 22] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/22/2013] [Revised: 07/24/2013] [Accepted: 08/25/2013] [Indexed: 02/02/2023]
Abstract
Accurate localization of joint centers is essential in movement analysis. However, joint centers cannot be directly palpated and alternative methods must be used. To assess the relative merits of these methods, a medical image based reference should be used. The EOS(®) system, a new low dose bi-planar X-rays imaging technique may be considered. The aim of this study was to evaluate the accuracy of hip joint center (HJC) localization using the EOS(®) system. Seventeen healthy young adults participated in the study. Femoral heads and pelvic external markers were localized using the EOS(®) system and the HJCs were expressed in the movement analysis coordinate system. Results showed that external marker localization was reliable within 0.15 mm for trained assessors. Mean accuracy for HJC localization was 2.9 mm (SD: 1.3, max: 6.2). The EOS based method therefore appeared reliable and may be used for femoral head localization or as a reference to assess the accuracy of other methods for HJC localization.
Collapse
Affiliation(s)
- Hélène Pillet
- Arts et Metiers ParisTech, LBM, 151 bd de l'hopital, 75013 Paris, France.
| | | | | | | | | |
Collapse
|
15
|
Robust 2D/3D registration for fast-flexion motion of the knee joint using hybrid optimization. Radiol Phys Technol 2012; 6:170-9. [PMID: 23138929 DOI: 10.1007/s12194-012-0185-y] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/10/2012] [Revised: 10/22/2012] [Accepted: 10/24/2012] [Indexed: 10/27/2022]
Abstract
Previously, we proposed a 2D/3D registration method that uses Powell's algorithm to obtain 3D motion of a knee joint by 3D computed-tomography and bi-plane fluoroscopic images. The 2D/3D registration is performed consecutively and automatically for each frame of the fluoroscopic images. This method starts from the optimum parameters of the previous frame for each frame except for the first one, and it searches for the next set of optimum parameters using Powell's algorithm. However, if the flexion motion of the knee joint is fast, it is likely that Powell's algorithm will provide a mismatch because the initial parameters are far from the correct ones. In this study, we applied a hybrid optimization algorithm (HPS) combining Powell's algorithm with the Nelder-Mead simplex (NM-simplex) algorithm to overcome this problem. The performance of the HPS was compared with the separate performances of Powell's algorithm and the NM-simplex algorithm, the Quasi-Newton algorithm and hybrid optimization algorithm with the Quasi-Newton and NM-simplex algorithms with five patient data sets in terms of the root-mean-square error (RMSE), target registration error (TRE), success rate, and processing time. The RMSE, TRE, and the success rate of the HPS were better than those of the other optimization algorithms, and the processing time was similar to that of Powell's algorithm alone.
Collapse
|
16
|
Jerbi T, Burdin V, Leboucher J, Stindel E, Roux C. 2-D-3-D frequency registration using a low-dose radiographic system for knee motion estimation. IEEE Trans Biomed Eng 2012; 60:813-20. [PMID: 22361657 DOI: 10.1109/tbme.2012.2188526] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022]
Abstract
In this paper, a new method is presented to study the feasibility of the pose and the position estimation of bone structures using a low-dose radiographic system, the entrepreneurial operating system (designed by EOS-Imaging Company). This method is based on a 2-D-3-D registration of EOS bi-planar X-ray images with an EOS 3-D reconstruction. This technique is relevant to such an application thanks to the EOS ability to simultaneously make acquisitions of frontal and sagittal radiographs, and also to produce a 3-D surface reconstruction with its attached software. In this paper, the pose and position of a bone in radiographs is estimated through the link between 3-D and 2-D data. This relationship is established in the frequency domain using the Fourier central slice theorem. To estimate the pose and position of the bone, we define a distance between the 3-D data and the radiographs, and use an iterative optimization approach to converge toward the best estimation. In this paper, we give the mathematical details of the method. We also show the experimental protocol and the results, which validate our approach.
Collapse
Affiliation(s)
- Taha Jerbi
- Institut Telecom/Télécom Bretagne, Brest, France.
| | | | | | | | | |
Collapse
|