Li W, Fang L, Li J. Exposure Doses to Technologists Working in 7 PET/CT Departments.
Dose Response 2020;
18:1559325820938288. [PMID:
32694961 PMCID:
PMC7350403 DOI:
10.1177/1559325820938288]
[Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/04/2020] [Revised: 05/28/2020] [Accepted: 06/05/2020] [Indexed: 12/04/2022] Open
Abstract
Objective:
The aim of this study was to measure occupational exposure doses of technologists who dispense and inject radiopharmaceuticals in 7 positron emission tomography/computed tomography (PET/CT) departments. This was done with the goal to help improving protective designs in PET departments and/or establishing national protection standards.
Method:
Common LiF thermoluminescence dosimeters (TLDs) were placed on the chest and necklace of the technologists to monitor whole-body and thyroid doses, respectively. Ring TLDs were also worn on both index fingers to measure individual hand doses. All TLDs were assembled and measured once every 3 months for a total of 12 months. Additionally, we measured and compared the dose of TLDs attached to both the inside and the outside of the technologist’s lead coat.
Results:
Technologists received relatively high exposures, which accounted for 64% to 94% of the collective dose in their respective departments. Their thyroid doses ranged from 1.2 to 1.7 mSv/a; some technologists’ hand doses exceeded 500 mSv/a. Use of a lead coat reduced the average dose by 8%.
Conclusion:
Technologists working in PET/CT departments were the main population exposed to radiation. This work underscores the need for enhanced protective measures for these workers to better reduce their exposure, particularly for their hands.
Collapse