1
|
Ozturk AM, Ozer MA, Suer O, Derin O, Govsa F, Aktuglu K. Evaluation of the effects of using 3D - patient specific models of displaced intra - articular calcaneal fractures in surgery. Injury 2022; 53 Suppl 2:S40-S51. [PMID: 32456955 DOI: 10.1016/j.injury.2020.04.057] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/23/2020] [Revised: 04/26/2020] [Accepted: 04/29/2020] [Indexed: 02/02/2023]
Abstract
BACKGROUND It was aimed to compare conventional surgery and three-dimensional (3D) model-assisted surgery used in the treatment of calcaneal fractures. MATERIALS & METHODS A total of 37 patients with unilateral calcaneal fractures were randomly divided into two groups as a conventional surgery group (n: 19) and a 3D model-assisted surgery group (n: 18). The preoperative, postoperative and last follow up angles of the Bohler and Gissane, calcaneal width and facet height were measured. The duration of the operation, blood loss volume, fluoroscopy usage, instrumentation time for both groups were recorded. Finally, the follow-up AOFAS scores were evaluated. A questionnaire was used to determine the perceptions of the resident doctors about the 3D model. RESULTS The duration of the operation, blood loss volume, fluoroscopy usage, instrumentation time for 3D model-assisted surgery group were 83.3 ± 4.6 minutes, 83.6 ± 4.6 ml, 6.8 ± 1.4 times and 13.0 ± 0.8 weeks, and as for conventional group they were 130.0 ± 5.8 minutes, 105.1 ± 5.6 minutes, 11.7 ± 1.5 ml, 22.2 ± 2.4 times and 13.3 ± 0.8 weeks, respectively (p < 0.0001). The both groups significantly restored Bohler angle, Gissane angle, calcaneal width and calcaneal facet height after operation (p < 0.0001). The 3D model-assisted group was significantly more succesful in restoration and protection of achieved correction of calcanel facet height (p < 0.0001). The difference was determined among the groups at the final follow-up examination with respect to the amount of change according the values achieved post-op. were significant in Bohler angle (p < 0.001), calcaneal facet height (p < 0.0001) and calcaneal widht (p = 0.017). There was no significant difference between AOFAS scores of the two groups at last follow-up. Resident doctors exhibited high scores of overall satisfaction with the use of a 3D printing model. CONCLUSIONS Compared to the conventional group, the 3D model-assisted group provide successful intervention and reduce operation, instrumentation time and the fluoroscopy usage with less blood loss. Performing 3D-assisted surgery helps the quality of reduction during the surgery and stability of internal fixation to protect achieved reduction at follow-up more succesfully.
Collapse
Affiliation(s)
- Anil Murat Ozturk
- Department of Ortopaedic Surgery, Faculty of Medicine, Ege University, Izmir, TURKEY
| | - Mehmet Asim Ozer
- Department of Anatomy Digital Imaging and 3D Modelling Laboratory, Faculty of Medicine, Ege University, Izmir, TURKEY
| | - Onur Suer
- Department of Ortopaedic Surgery, Faculty of Medicine, Ege University, Izmir, TURKEY
| | - Okan Derin
- Department of Anatomy Digital Imaging and 3D Modelling Laboratory, Faculty of Medicine, Ege University, Izmir, TURKEY
| | - Figen Govsa
- Department of Anatomy Digital Imaging and 3D Modelling Laboratory, Faculty of Medicine, Ege University, Izmir, TURKEY
| | - Kemal Aktuglu
- Department of Ortopaedic Surgery, Faculty of Medicine, Ege University, Izmir, TURKEY.
| |
Collapse
|
2
|
Yuan X, Zhang B, Hu J, Lu B, Tang Z. [A comparative study on internal fixation of calcaneal fractures assisted by robot and traditional open reduction internal fixation]. ZHONGGUO XIU FU CHONG JIAN WAI KE ZA ZHI = ZHONGGUO XIUFU CHONGJIAN WAIKE ZAZHI = CHINESE JOURNAL OF REPARATIVE AND RECONSTRUCTIVE SURGERY 2021; 35:729-733. [PMID: 34142500 DOI: 10.7507/1002-1892.202101029] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Subscribe] [Scholar Register] [Indexed: 11/03/2022]
Abstract
Objective To compare the effectiveness of robot assisted internal fixation and traditional open reduction and internal fixation for calcaneal fractures. Methods The clinical data of 44 patients (44 feets) with calcaneal fracture admitted between October 2017 and December 2018 who met the selection criteria were retrospectively analyzed. According to different operation methods, they were divided into trial group (19 cases, treated with robot assisted percutaneous reduction and cannulated screw fixation through tarsal sinus incision) and control group (25 cases, treated with open reduction and internal fixation via traditional tarsal sinus incision). There was no significant difference in gender, age, injured side, cause of injury, fracture type, time from injury to operation, and preoperative Böhler angle, Gissane angle, calcaneus width, American Orthopedic Foot and Ankle Association (AOFAS) score, and other general data between the two groups ( P>0.05). The operation time, intraoperative fluoroscopy frequency, and fracture healing time were recorded and compared between the two groups. Before operation and at 6 months after operation, the Böhler angle and Gissane angle were measured on the lateral X-ray film, and the calcaneal width was measured on the axial X-ray film of the calcaneus to evaluate the recovery of the deformity and collapse after surgical treatment; the AOFAS score was used to evaluate the function of the affected foot and ankle joint. Results The operation time of the trial group was significantly longer than that of the control group ( P<0.05), but the intraoperative fluoroscopy frequency was significantly less than that of the control group ( P<0.05). In the control group, 1 case had skin necrosis, and 1 case had a little leakage from the incision; the rest of the two groups had no skin- and incision-related complications. Patients in both groups were followed up 6-12 months, with an average of 9.5 months. At 6 months after operation, the Böhler angle, Gissane angle, and calcaneal width in the two groups were significantly improved when compared with preoperative ones ( P<0.05), and there was no significant difference between the two groups ( P>0.05); the fractures in the two groups were healed, there was no significant difference in healing time ( t=-1.890, P=0.066); the AOFAS scores of the two groups were significantly higher than those before operation ( P<0.05), and the AOFAS score of the trial group was significantly higher than that of the control group ( t=-3.135, P=0.003). Conclusion Compared with traditional C-arm fluoroscopic internal fixation for calcaneal fractures, robot-assisted internal fixation via tarsal sinus incision for calcaneal fractures significantly improves the function of the affected foot and maintains the accuracy of nail implantation after fracture reduction, reducing intraoperative fluoroscopy times, and the fracture heals well.
Collapse
Affiliation(s)
- Xinwei Yuan
- Department of Orthopedics, Sichuan Provincial People's Hospital, Sichuan Academy of Medical Sciences, Chengdu Sichuan, 610072, P.R.China
| | - Bin Zhang
- Department of Orthopedics, Sichuan Provincial People's Hospital, Sichuan Academy of Medical Sciences, Chengdu Sichuan, 610072, P.R.China
| | - Jiang Hu
- Department of Orthopedics, Sichuan Provincial People's Hospital, Sichuan Academy of Medical Sciences, Chengdu Sichuan, 610072, P.R.China
| | - Bing Lu
- Department of Orthopedics, Sichuan Provincial People's Hospital, Sichuan Academy of Medical Sciences, Chengdu Sichuan, 610072, P.R.China
| | - Zhi Tang
- Department of Orthopedics, Sichuan Provincial People's Hospital, Sichuan Academy of Medical Sciences, Chengdu Sichuan, 610072, P.R.China
| |
Collapse
|
3
|
Morsi IM, Khalifa AA, Hussien MA, Abdellatef A, Refae H. Evaluation of the short-term results of closed reduction and percutaneous K-wires fixation of displaced intra-articular calcaneal fractures (DIACF). Foot (Edinb) 2020; 45:101740. [PMID: 33011495 DOI: 10.1016/j.foot.2020.101740] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/16/2020] [Revised: 07/06/2020] [Accepted: 08/29/2020] [Indexed: 02/04/2023]
Abstract
PURPOSE Optimum management of displaced intra-articular calcaneal fractures (DIACF) still controversial. Open surgery carries the risk of wound complications, while non-operative management has a high incidence of arthrosis. To avoid these complications, minimally invasive and percutaneous fixation was introduced. The purpose of this study was to prospectively evaluate the short term clinical and radiological outcomes after closed reduction and percutaneous fixation of DIACF using K-wires. PATIENTS AND METHODS Outcomes of twenty patients were evaluated at the final follow up. A functional assessment using the AOFAS scoring system. Radiological parameters recorded included three angles (Böhler's, Gissane and posterior facet inclination angles) and three distances (calcaneal length, height and width). Any complications were reported at any follow-up. RESULTS The mean patient's age was 33 ± 15.2 years, 8 (40%) patients with type II fractures, 10 (50%) patients with type III fractures, and 2 (10%) with type IV fracture according to Sanders classification. After a mean follow-up of 9 months, the mean AOFAS score was 84, excellent in 9 patients (45%), good in 9 (45%), and fair in 2 (10%). At the final follow-up the Böhler's angle, Gissane angle and PFIA was 25.1° ± (5.2), 119.9° ± (9.4) and 51.7° ± (5.9) respectively and the calcaneal height, length and width was 41.8 mm ± (2.1), 75.1 mm ± (3.01) and 40.9 mm ± (2.6) respectively. We had no cases of deep infection, 20% had significant subtalar arthritis. CONCLUSION The closed reduction and percutaneous fixation technique for DIACF management offered acceptable clinical and radiographic outcomes, with fewer complications when compared to other management options.
Collapse
Affiliation(s)
- Ibrahim Mahmoud Morsi
- Orthopedics and Traumatology Department, Aswan Faculty of Medicine, Aswan University, Aswan, Egypt.
| | - Ahmed A Khalifa
- Orthopaedic Department, Qena Faculty of Medicine and University Hospital, South Valley University, Qena, Egypt.
| | | | - Ahmed Abdellatef
- Orthopedics and Traumatology Department, Aswan Faculty of Medicine, Aswan University, Aswan, Egypt.
| | - Hesham Refae
- Orthopedics and Traumatology Department, Aswan Faculty of Medicine, Aswan University, Aswan, Egypt.
| |
Collapse
|
4
|
Wang C, Xu C, Li M, Li H, Xiao H, Zhong D, Liu H. Patient-specific instrument-assisted minimally invasive internal fixation of calcaneal fracture for rapid and accurate execution of a preoperative plan: A retrospective study. BMC Musculoskelet Disord 2020; 21:407. [PMID: 32593302 PMCID: PMC7321547 DOI: 10.1186/s12891-020-03439-3] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/05/2020] [Accepted: 06/18/2020] [Indexed: 11/10/2022] Open
Abstract
Background Traditional methods for minimally invasive internal fixation (MIIF) of calcaneal fractures require extensive intraoperative fluoroscopy, and fracture recovery is usually not ideal. We developed a new surgical procedure using digital surgical simulation and constructed a patient-specific instrument (PSI) for calcaneal fracture that we used during the operation. This study investigated whether PSI-assisted MIIF of calcaneal fracture enables rapid and accurate execution of the preoperative plan. Methods We retrospectively analyzed patients with Sanders type III or IV fresh calcaneal fractures who had undergone PSI-assisted MIIF at our hospital from January 2016 to December 2018. We analyzed perioperative data including intraoperative fluoroscopy time, concurrence of internal fixation actual usage (IFAU) with the preoperative plan, surgery time, and complications. We also compared pre- and postoperative actual measurements from X-ray radiographs and computed tomography images including Böhler, Gissane, and calcaneus valgus angles; subtalar joint width; and calcaneal volume overlap ratio with the preoperative design. All patients had been followed up and their American Orthopedic Foot and Ankle Score (AOFAS) score was available. Results Mean intraoperative fluoroscopy time was 3.95 ± 1.78 h; IFAU in 16 patients (16 ft) was the same as the preoperative plan; mean surgery time was 28.16 ± 10.70 min; and none of the patients developed complications. Böhler, Gissane, and calcaneus valgus angles and subtalar joint width did not differ between pre- and postoperative plans; however, the actual preoperative values of each of these parameters differed significantly from those measured postoperatively. The calcaneal volume overlap ratio with the preoperative design was 91.2% ± 2.3%. AOFAS scores increased with time, with significant differences in the score at each time point. Conclusions The newly developed PSI-assisted calcaneal fracture MIIF method can rapidly and accurately execute the preoperative plan.
Collapse
Affiliation(s)
- Chenggong Wang
- Department of Orthopedics, Xiangya Hospital Central South University, No.87 Xiangya Road, Changsha, 410008, Hunan, China.,Department of foot and ankle surgery, Xiangya Hospital Central South University, No.87 Xiangya Road, Changsha, 410008, Hunan, China
| | - Can Xu
- Department of Orthopedics, Xiangya Hospital Central South University, No.87 Xiangya Road, Changsha, 410008, Hunan, China.,Department of foot and ankle surgery, Xiangya Hospital Central South University, No.87 Xiangya Road, Changsha, 410008, Hunan, China
| | - Mingqing Li
- Department of Orthopedics, Xiangya Hospital Central South University, No.87 Xiangya Road, Changsha, 410008, Hunan, China.,Department of foot and ankle surgery, Xiangya Hospital Central South University, No.87 Xiangya Road, Changsha, 410008, Hunan, China
| | - Hui Li
- Department of Orthopedics, Xiangya Hospital Central South University, No.87 Xiangya Road, Changsha, 410008, Hunan, China.,Department of foot and ankle surgery, Xiangya Hospital Central South University, No.87 Xiangya Road, Changsha, 410008, Hunan, China
| | - Han Xiao
- Department of Sports Medicine, Xiangya Hospital Central South University, No.87 Xiangya Road, Changsha, 410008, Hunan, China
| | - Da Zhong
- Department of Orthopedics, Xiangya Hospital Central South University, No.87 Xiangya Road, Changsha, 410008, Hunan, China
| | - Hua Liu
- Department of Orthopedics, Xiangya Hospital Central South University, No.87 Xiangya Road, Changsha, 410008, Hunan, China. .,Department of foot and ankle surgery, Xiangya Hospital Central South University, No.87 Xiangya Road, Changsha, 410008, Hunan, China.
| |
Collapse
|