1
|
Pourvaziri A, Mroueh N, Cochran RL, Srinivas Rao S, Kambadakone A. Beyond Conventional CT: Role of Dual-Energy CT in Monitoring Response to Therapy in Abdominal Malignancies. Radiol Imaging Cancer 2025; 7:e240142. [PMID: 40249270 DOI: 10.1148/rycan.240142] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 04/19/2025]
Abstract
In the era of precision medicine, imaging plays a critical role in evaluating treatment response to various oncologic therapies. For decades, conventional morphologic assessments using cross-sectional imaging have been the standard for monitoring the effectiveness of systemic and locoregional therapies in patients with cancer. However, the development of new functional imaging tools has widened the scope of imaging from mere response assessment to patient selection and outcome prediction. Dual-energy CT (DECT), known for its superior material differentiation capabilities, shows promise in enhancing treatment response evaluation. DECT-based iodine quantification methods are increasingly being investigated as surrogates for assessing tumor vascularity and physiology, which is particularly important in patients undergoing emerging targeted therapies. The purpose of this review article is to discuss the current and emerging role of DECT in assessing treatment response in patients with malignant abdominal tumors. Keywords: CT-Dual Energy, Transcatheter Tumor Therapy, Tumor Response, Iodine Uptake, Therapeutic Response © RSNA, 2025.
Collapse
Affiliation(s)
- Ali Pourvaziri
- Department of Radiology, Massachusetts General Hospital, 55 Fruit St, Boston, MA 02114
| | - Nayla Mroueh
- Department of Radiology, Massachusetts General Hospital, 55 Fruit St, Boston, MA 02114
| | - Rory L Cochran
- Department of Radiology, Massachusetts General Hospital, 55 Fruit St, Boston, MA 02114
| | - Shravya Srinivas Rao
- Department of Radiology, Massachusetts General Hospital, 55 Fruit St, Boston, MA 02114
| | - Avinash Kambadakone
- Department of Radiology, Massachusetts General Hospital, 55 Fruit St, Boston, MA 02114
| |
Collapse
|
2
|
Gómez FM, Van der Reijd DJ, Panfilov IA, Baetens T, Wiese K, Haverkamp-Begemann N, Lam SW, Runge JH, Rice SL, Klompenhouwer EG, Maas M, Helmberger T, Beets-Tan RG. Imaging in interventional oncology, the better you see, the better you treat. J Med Imaging Radiat Oncol 2023; 67:895-902. [PMID: 38062853 DOI: 10.1111/1754-9485.13610] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/06/2023] [Accepted: 11/22/2023] [Indexed: 01/14/2024]
Abstract
Imaging and image processing is the fundamental pillar of interventional oncology in which diagnostic, procedure planning, treatment and follow-up are sustained. Knowing all the possibilities that the different image modalities can offer is capital to select the most appropriate and accurate guidance for interventional procedures. Despite there is a wide variability in physicians preferences and availability of the different image modalities to guide interventional procedures, it is important to recognize the advantages and limitations for each of them. In this review, we aim to provide an overview of the most frequently used image guidance modalities for interventional procedures and its typical and future applications including angiography, computed tomography (CT) and spectral CT, magnetic resonance imaging, Ultrasound and the use of hybrid systems. Finally, we resume the possible role of artificial intelligence related to image in patient selection, treatment and follow-up.
Collapse
Affiliation(s)
- Fernando M Gómez
- Grupo de Investigación Biomédica en Imagen, Instituto de Investigación Sanitaria La Fe, Valencia, Spain
- Área Clínica de Imagen Médica, Hospital Universitario y Politécnico La Fe, Valencia, Spain
- Department of Radiology, The Netherlands Cancer Institute, Amsterdam, The Netherlands
| | | | - Ilia A Panfilov
- Department of Radiology, The Netherlands Cancer Institute, Amsterdam, The Netherlands
| | - Tarik Baetens
- Department of Radiology, The Netherlands Cancer Institute, Amsterdam, The Netherlands
| | - Kevin Wiese
- Department of Radiology, The Netherlands Cancer Institute, Amsterdam, The Netherlands
| | | | - Siu W Lam
- Department of Radiology, The Netherlands Cancer Institute, Amsterdam, The Netherlands
| | - Jurgen H Runge
- Department of Radiology, The Netherlands Cancer Institute, Amsterdam, The Netherlands
| | - Samuel L Rice
- Radiology, Interventional Radiology Section, UT Southwestern Medical Center, Dallas, TX, USA
| | | | - Monique Maas
- Department of Radiology, The Netherlands Cancer Institute, Amsterdam, The Netherlands
| | - Thomas Helmberger
- Institut für Radiologie, Neuroradiologie und Minimal-Invasive Therapie, München Klinik Bogenhausen, Munich, Germany
| | - Regina Gh Beets-Tan
- Department of Radiology, The Netherlands Cancer Institute, Amsterdam, The Netherlands
- GROW School for Oncology and Developmental Biology, University of Maastricht, Maastricht, The Netherlands
| |
Collapse
|
3
|
Update on Image-Guided Thermal Lung Ablation: Society Guidelines, Therapeutic Alternatives, and Postablation Imaging Findings. AJR Am J Roentgenol 2022; 219:471-485. [PMID: 35319908 DOI: 10.2214/ajr.21.27099] [Citation(s) in RCA: 30] [Impact Index Per Article: 10.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/19/2022]
Abstract
Percutaneous image-guided thermal ablation (IGTA) has been endorsed by multiple societies as a safe and effective lung-preserving treatment for primary lung cancer and metastases involving the lung and chest wall. This article reviews the role of IGTA in the care continuum of patients with thoracic neoplasms and discusses strategies to identify the optimal local therapy considering patient and tumor characteristics. The advantages and disadvantages of percutaneous thermal ablation compared to surgical resection and stereotactic body radiotherapy are summarized. Principles of radiofrequency ablation, microwave ablation, and cryoablation, as well as the emerging use of transbronchial thermal ablation, are described. Specific considerations are presented regarding the role of thermal ablation for early-stage non-small cell lung cancer (NSCLC), multifocal primary NSCLC, pulmonary metastases, salvage of recurrent NSCLC after surgery or radiation, and pain palliation for tumors involving the chest wall. Recent changes to professional society guidelines regarding the role of thermal ablation in the lung, including for treatment of oligometastatic disease, are highlighted. Finally, recommendations are provided for imaging follow-up after thermal ablation of lung tumors, accompanied by examples of expected postoperative findings and patterns of disease recurrence.
Collapse
|
4
|
Virtual Noncontrast Imaging of the Liver Using Photon-Counting Detector Computed Tomography: A Systematic Phantom and Patient Study. Invest Radiol 2022; 57:488-493. [PMID: 35136003 DOI: 10.1097/rli.0000000000000860] [Citation(s) in RCA: 29] [Impact Index Per Article: 9.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
Abstract
OBJECTIVES The aim of this study was to assess the accuracy of virtual noncontrast (VNC) images of the liver in a phantom and patients using dual-source photon-counting detector computed tomography (PCD-CT). MATERIALS AND METHODS An anthropomorphic abdominal phantom with a liver insert containing liver parenchyma (1.4 mgI/mL) and 19 liver lesions (iodine content 0-5 mgI/mL) was imaged on a clinical dual-source PCD-CT (tube voltage 120 kV) and in the dual-energy mode on a dual-source energy-integrating detector (EID) CT (tube voltage combinations, 80/Sn150 kV, 90/Sn150 kV, and 100/Sn150 kV). Rings of fat-equivalent material were added to the phantom to emulate 3 sizes (small, medium, large). Each setup was imaged at 3 different radiation doses (volume CT dose index: 5, 10, and 15 mGy). Virtual noncontrast images were reconstructed and CT attenuation was measured in each lesion and liver parenchyma. The absolute error of CT attenuation (VNCerror) was calculated using the phantom specifications as reference. In addition, 15 patients with hypodense liver lesions who were clinically scanned on PCD-CT were retrospectively included. Attenuation values in lesions and liver parenchyma in VNC images reconstructed from portal venous phase CT were compared with true noncontrast images. Statistical analysis included analysis of variance with post hoc t tests and generalized linear models to assess the impact of various variables (dose, patient size, base material, iodine content, and scanner/scan mode) on quantification accuracy. RESULTS In the phantom, the overall mean VNCerror for PCD-CT was 4.1 ± 3.9 HU. The overall mean VNCerror for EID-CT was 7.5 ± 5, 6.3 ± 4.7, and 6.7 ± 4.8 HU for 80/Sn150 kV, 90/Sn150 kV, and 100/Sn150 kV, respectively, with the VNCerror of EID-CT being significantly higher at all tube voltage settings (P < 0.001), even after adjusting for dose, size, iodine content of the lesion, and attenuation of base material. For PCD-CT, a smaller phantom size was associated with higher quantification accuracy (P = 0.007-0.046), whereas radiation dose did not impact accuracy (P > 0.126). For EID-CT, but not for PCD-CT, VNCerror increased with lesion iodine content (P < 0.001). In patients, there was no difference in attenuation measured on true noncontrast and VNC images (P = 0.093), with a mean VNCerror of 3.7 ± 2.2 HU. CONCLUSIONS Photon-counting detector CT allows for the reconstruction of VNC images of the liver both in a phantom and in patients with accurate attenuation values, being independent of dose, attenuation of base material, and liver iodine content.
Collapse
|
5
|
Crocetti L, Amabile C, Scalise P, Tosoratti N, Bozzi E, Rossi P, Cervelli R, Cassarino S, Cioni R. Predicting the coagulation volume induced by microwave ablation of hepatocellular carcinoma: the role of deposited energy, ex-vivo bovine liver charts and central hyperdense area on post-treatment CT. Int J Hyperthermia 2021; 38:1486-1494. [PMID: 34927518 DOI: 10.1080/02656736.2021.1986642] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/20/2022] Open
Abstract
PURPOSE To study the correlation between the overall coagulation zone (A) attained in percutaneous microwave ablation (MWA) of hepatocellular carcinomas (HCC) and: (1) the hyperdense zone (C) visible in the central part of zone A on post-treatment unenhanced CT scans; (2) the deposited energy; (3) the coagulation zones observed on ex-vivo bovine liver. MATERIALS AND METHODS The post-procedural computed tomography (CT) scans of HCCs treated with a single energy deployment through the same 2450 MHz MWA system were retrospectively analyzed, retrieving the dimensions of A and C zones and the deposited energy (E). Ex-vivo bovine liver MWA with the same system were performed and analyzed to determine the same quantities by gross-pathologic examination and CT imaging. RESULTS A total of 101 HCC treatments were analyzed. The average coagulation volumes increased linearly with deposited energy (1.11 cc/kJ, R2 = 0.90, 4.2 kJ ≤ E ≤ 48 kJ), similarly to ex-vivo findings (1.38 cc/kJ, R2 =0.97, 7.2 kJ ≤ E ≤ 144 kJ). The long axis (L) and short axis (D) of zones A and C held a fairly constant ratio both in-vivo (LC/LA=0.43 ± 0.13; DC/DA=0.42 ± 0.10) and ex-vivo (LC/LA = 0.49 ± 0.07; DC/DA = 0.28 ± 0.06). CONCLUSIONS The average dimensions of the ablation zone induced by the considered system on HCC increase linearly with the deposited energy and are fairly well predicted by the corresponding ex-vivo dimensions. The ratio between each linear dimension of A and C zones was found to be roughly constant over a large deposited energy span, both ex-vivo and in-vivo.
Collapse
Affiliation(s)
- Laura Crocetti
- Division of Interventional Radiology, University of Pisa, Pisa, Italy
| | | | - Paola Scalise
- Division of Interventional Radiology, University of Pisa, Pisa, Italy
| | | | - Elena Bozzi
- Division of Interventional Radiology, University of Pisa, Pisa, Italy
| | - Piercarlo Rossi
- Division of Interventional Radiology, University of Pisa, Pisa, Italy
| | - Rosa Cervelli
- Division of Interventional Radiology, University of Pisa, Pisa, Italy
| | | | - Roberto Cioni
- Division of Interventional Radiology, University of Pisa, Pisa, Italy
| |
Collapse
|
6
|
Ji X, Feng M, Treb K, Zhang R, Schafer S, Li K. Development of an Integrated C-Arm Interventional Imaging System With a Strip Photon Counting Detector and a Flat Panel Detector. IEEE TRANSACTIONS ON MEDICAL IMAGING 2021; 40:3674-3685. [PMID: 34232872 DOI: 10.1109/tmi.2021.3095419] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/13/2023]
Abstract
Modern interventional x-ray systems are often equipped with flat-panel detector-based cone-beam CT (FPD-CBCT) to provide tomographic, volumetric, and high spatial resolution imaging of interventional devices, iodinated vessels, and other objects. The purpose of this work was to bring an interchangeable strip photon-counting detector (PCD) to C-arm systems to supplement (instead of retiring) the existing FPD-CBCT with a high quality, spectral, and affordable PCD-CT imaging option. With minimal modification to the existing C-arm, a 51×0.6 cm2 PCD with a 0.75 mm CdTe layer, two energy thresholds, and 0.1 mm pixels was integrated with a Siemens Artis Zee interventional imaging system. The PCD can be translated in and out of the field-of-view to allow the system to switch between FPD and PCD-CT imaging modes. A dedicated phantom and a new algorithm were developed to calibrate the projection geometry of the narrow-beam PCD-CT system and correct the gantry wobbling-induced geometric distortion artifacts. In addition, a detector response calibration procedure was performed for each PCD pixel using materials with known radiological pathlengths to address concentric artifacts in PCD-CT images. Both phantom and human cadaver experiments were performed at a high gantry rotation speed and clinically relevant radiation dose level to evaluate the spectral and non-spectral imaging performance of the prototype system. Results show that the PCD-CT system has excellent image quality with negligible artifacts after the proposed corrections. Compared with FPD-CBCT images acquired at the same dose level, PCD-CT images demonstrated a 53% reduction in noise variance and additional quantitative imaging capability.
Collapse
|
7
|
Majeed NF, Braschi Amirfarzan M, Wald C, Wortman JR. Spectral detector CT applications in advanced liver imaging. Br J Radiol 2021; 94:20201290. [PMID: 34048285 PMCID: PMC8248211 DOI: 10.1259/bjr.20201290] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/30/2020] [Revised: 04/16/2021] [Accepted: 05/13/2021] [Indexed: 12/11/2022] Open
Abstract
OBJECTIVE Spectral detector CT (SDCT) has many applications in advanced liver imaging. If appropriately utilized, this technology has the potential to improve image quality, provide new diagnostic information, and allow for decreased radiation dose. The purpose of this review is to familiarize radiologists with the uses of SDCT in liver imaging. CONCLUSION SDCT has a variety of post-processing techniques, which can be used in advanced liver imaging and can significantly add value in clinical practice.
Collapse
Affiliation(s)
- Noor Fatima Majeed
- Department of Radiology, Lahey Hospital and Medical Center, 41 Burlington Mall Road, Burlington, United States
| | - Marta Braschi Amirfarzan
- Department of Radiology, Lahey Hospital and Medical Center, 41 Burlington Mall Road, Burlington, United States
| | - Christoph Wald
- Department of Radiology, Lahey Hospital and Medical Center, 41 Burlington Mall Road, Burlington, United States
| | - Jeremy R Wortman
- Department of Radiology, Lahey Hospital and Medical Center, 41 Burlington Mall Road, Burlington, United States
| |
Collapse
|
8
|
Reimer RP, Hokamp NG, Niehoff J, Zopfs D, Lennartz S, Heidar M, Wahba R, Stippel D, Maintz D, dos Santos DP, Wybranski C. Value of spectral detector computed tomography for the early assessment of technique efficacy after microwave ablation of hepatocellular carcinoma. PLoS One 2021; 16:e0252678. [PMID: 34129650 PMCID: PMC8205161 DOI: 10.1371/journal.pone.0252678] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/20/2020] [Accepted: 05/19/2021] [Indexed: 12/15/2022] Open
Abstract
OBJECTIVES To investigate whether virtual monoenergetic images (VMI) and iodine maps derived from spectral detector computed tomography (SDCT) improve early assessment of technique efficacy in patients who underwent microwave ablation (MWA) for hepatocellular carcinoma (HCC) in liver cirrhosis. METHODS This retrospective study comprised 39 patients with 49 HCC lesions treated with MWA. Biphasic SDCT was performed 7.7±4.0 days after ablation. Conventional images (CI), VMI and IM were reconstructed. Signal- and contrast-to-noise ratio (SNR, CNR) in the ablation zone (AZ), hyperemic rim (HR) and liver parenchyma were calculated using regions-of-interest analysis and compared between CI and VMI between 40-100 keV. Iodine concentration and perfusion ratio of HR and residual tumor (RT) were measured. Two readers evaluated subjective contrast of AZ and HR, technique efficacy (complete vs. incomplete ablation) and diagnostic confidence at determining technique efficacy. RESULTS Attenuation of liver parenchyma, HR and RT, SNR of liver parenchyma and HR, CNR of AZ and HR were significantly higher in low-keV VMI compared to CI (all p<0.05). Iodine concentration and perfusion ratio differed significantly between HR and RT (all p<0.05; e.g. iodine concentration, 1.6±0.5 vs. 2.7±1.3 mg/ml). VMI50keV improved subjective AZ-to-liver contrast, HR-to-liver contrast, visualization of AZ margin and vessels adjacent to AZ compared to CI (all p<0.05). Diagnostic accuracy for detection of incomplete ablation was slightly higher in VMI50keV compared to CI (0.92 vs. 0.89), while diagnostic confidence was significantly higher in VMI50keV (p<0.05). CONCLUSIONS Spectral detector computed tomography derived low-keV virtual monoenergetic images and iodine maps provide superior early assessment of technique efficacy of MWA in HCC compared to CI.
Collapse
Affiliation(s)
- Robert Peter Reimer
- Faculty of Medicine and University Hospital Cologne, Department of Diagnostic and Interventional Radiology, University of Cologne, Cologne, Germany
- * E-mail:
| | - Nils Große Hokamp
- Faculty of Medicine and University Hospital Cologne, Department of Diagnostic and Interventional Radiology, University of Cologne, Cologne, Germany
| | - Julius Niehoff
- Faculty of Medicine and University Hospital Cologne, Department of Diagnostic and Interventional Radiology, University of Cologne, Cologne, Germany
| | - David Zopfs
- Faculty of Medicine and University Hospital Cologne, Department of Diagnostic and Interventional Radiology, University of Cologne, Cologne, Germany
| | - Simon Lennartz
- Faculty of Medicine and University Hospital Cologne, Department of Diagnostic and Interventional Radiology, University of Cologne, Cologne, Germany
- Department of Radiology, Massachusetts General Hospital, Boston, MA, United States of America
| | - Mariam Heidar
- Faculty of Medicine, University Cologne, Cologne, Germany
| | - Roger Wahba
- Faculty of Medicine and University Hospital Cologne, Department of General-, Visceral, Cancer and Transplant Surgery, University of Cologne, Cologne, Germany
| | - Dirk Stippel
- Faculty of Medicine and University Hospital Cologne, Department of General-, Visceral, Cancer and Transplant Surgery, University of Cologne, Cologne, Germany
| | - David Maintz
- Faculty of Medicine and University Hospital Cologne, Department of Diagnostic and Interventional Radiology, University of Cologne, Cologne, Germany
| | - Daniel Pinto dos Santos
- Faculty of Medicine and University Hospital Cologne, Department of Diagnostic and Interventional Radiology, University of Cologne, Cologne, Germany
| | - Christian Wybranski
- Faculty of Medicine and University Hospital Cologne, Department of Diagnostic and Interventional Radiology, University of Cologne, Cologne, Germany
| |
Collapse
|
9
|
Thiravit S, Brunnquell C, Cai LM, Flemon M, Mileto A. Use of dual-energy CT for renal mass assessment. Eur Radiol 2020; 31:3721-3733. [PMID: 33210200 DOI: 10.1007/s00330-020-07426-z] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/05/2020] [Revised: 08/11/2020] [Accepted: 10/14/2020] [Indexed: 12/22/2022]
Abstract
Although dual-energy CT (DECT) may prove useful in a variety of abdominal imaging tasks, renal mass evaluation represents the area where this technology can be most impactful in abdominal imaging compared to routinely performed contrast-enhanced-only single-energy CT exams. DECT post-processing techniques, such as creation of virtual unenhanced and iodine density images, can help in the characterization of incidentally discovered renal masses that would otherwise remain indeterminate based on post-contrast imaging only. The purpose of this article is to review the use of DECT for renal mass assessment, including its benefits and existing limitations. KEY POINTS: • If DECT is selected as the scanning mode for most common abdominal protocols, many incidentally found renal masses can be fully triaged within the same exam. • Virtual unenhanced and iodine density DECT images can provide additional information when renal masses are discovered in the post-contrast-only setting. • For renal mass evaluation, virtual unenhanced and iodine density DECT images should be interpreted side-by-side to troubleshoot pitfalls that can potentially lead to erroneous interpretation.
Collapse
Affiliation(s)
- Shanigarn Thiravit
- Department of Radiology, University of Washington School of Medicine, 1959 NE Pacific Street, Box 357115, Seattle, WA, 98195, USA.,Division of Diagnostic Radiology, Department of Radiology, Faculty of Medicine, Siriraj Hospital, Mahidol University, Bangkok, Thailand
| | - Christina Brunnquell
- Department of Radiology, University of Washington School of Medicine, 1959 NE Pacific Street, Box 357115, Seattle, WA, 98195, USA
| | - Larry M Cai
- Department of Radiology, University of Washington School of Medicine, 1959 NE Pacific Street, Box 357115, Seattle, WA, 98195, USA
| | - Mena Flemon
- Department of Radiology, University of Washington School of Medicine, 1959 NE Pacific Street, Box 357115, Seattle, WA, 98195, USA
| | - Achille Mileto
- Department of Radiology, University of Washington School of Medicine, 1959 NE Pacific Street, Box 357115, Seattle, WA, 98195, USA.
| |
Collapse
|
10
|
Laukamp KR, Ho V, Obmann VC, Herrmann K, Gupta A, Borggrefe J, Lennartz S, Große Hokamp N, Ramaiya N. Virtual non-contrast for evaluation of liver parenchyma and vessels: results from 25 patients using multi-phase spectral-detector CT. Acta Radiol 2020; 61:1143-1152. [PMID: 31856581 DOI: 10.1177/0284185119893094] [Citation(s) in RCA: 19] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/20/2022]
Abstract
BACKGROUND In abdominal imaging, contrast-enhanced computed tomography (CT) examinations are most commonly applied; however, unenhanced examinations are still needed for several clinical questions but require additional scanning and radiation exposure. PURPOSE To evaluate accuracy of virtual non-contrast (VNC) from arterial and venous phase spectral-detector CT (SDCT) scans compared to true-unenhanced (TNC) images for the evaluation of liver parenchyma and vessels. MATERIAL AND METHODS A total of 25 patients undergoing triphasic SDCT examinations were included. VNC was reconstructed from arterial and venous phases and compared to TNC images. Quantitative image analysis was performed by region of interest (ROI)-based assessment of mean and SD of attenuation (HU) in each liver segment, spleen, portal vein, common hepatic artery, and abdominal aorta. Subjectively, iodine subtraction and diagnostic assessment were rated on 5-point Likert scales. RESULTS Attenuation and image noise measured in the liver from VNC were not significantly different from TNC (TNC: 54.6 ± 10.8 HU, VNC arterial phase: 55.7 ± 10.8 HU; VNC venous phase: 58.3 ± 10.0 HU; P > 0.05). VNC also showed accurate results regarding attenuation and image noise for spleen, portal vein, and abdominal aorta. Only iodine subtraction in the common hepatic artery in the arterial phase was insufficient which was confirmed by the subjective reading. Apart from that, subjective reading showed accurate iodine subtraction and comparable diagnostic assessment. CONCLUSION VNC from the arterial and venous phases were very similar to TNC yielding mostly negligible differences in attenuation, image noise, and diagnostic utility. Inadequate iodine subtraction occurred in hepatic arteries in the arterial phase.
Collapse
Affiliation(s)
- Kai Roman Laukamp
- University Hospitals Cleveland Medical Center, Department of Radiology, Cleveland, OH, USA
- Case Western Reserve University, Department of Radiology, Cleveland, OH, USA
- Institute for Diagnostic and Interventional Radiology, Faculty of Medicine and University Hospital Cologne, University of Cologne, Cologne, Germany
| | - Vivian Ho
- University Hospitals Cleveland Medical Center, Department of Radiology, Cleveland, OH, USA
- Case Western Reserve University, Department of Radiology, Cleveland, OH, USA
| | - Verena Carola Obmann
- University Hospitals Cleveland Medical Center, Department of Radiology, Cleveland, OH, USA
- Case Western Reserve University, Department of Radiology, Cleveland, OH, USA
- Institute of Diagnostic, Interventional and Pediatric Radiology, University Hospital Bern, Bern, Switzerland
| | - Karin Herrmann
- University Hospitals Cleveland Medical Center, Department of Radiology, Cleveland, OH, USA
- Case Western Reserve University, Department of Radiology, Cleveland, OH, USA
| | - Amit Gupta
- University Hospitals Cleveland Medical Center, Department of Radiology, Cleveland, OH, USA
- Case Western Reserve University, Department of Radiology, Cleveland, OH, USA
| | - Jan Borggrefe
- Institute for Diagnostic and Interventional Radiology, Faculty of Medicine and University Hospital Cologne, University of Cologne, Cologne, Germany
| | - Simon Lennartz
- Institute for Diagnostic and Interventional Radiology, Faculty of Medicine and University Hospital Cologne, University of Cologne, Cologne, Germany
| | - Nils Große Hokamp
- University Hospitals Cleveland Medical Center, Department of Radiology, Cleveland, OH, USA
- Case Western Reserve University, Department of Radiology, Cleveland, OH, USA
- Institute for Diagnostic and Interventional Radiology, Faculty of Medicine and University Hospital Cologne, University of Cologne, Cologne, Germany
| | - Nikhil Ramaiya
- University Hospitals Cleveland Medical Center, Department of Radiology, Cleveland, OH, USA
- Case Western Reserve University, Department of Radiology, Cleveland, OH, USA
| |
Collapse
|
11
|
Große Hokamp N, Gupta A, Gilkeson RC. Stratification of Pulmonary Nodules Using Quantitative Iodine Maps from Dual-Energy Computed Tomography. Am J Respir Crit Care Med 2019; 199:e3-e4. [PMID: 30199642 DOI: 10.1164/rccm.201803-0506im] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/14/2022] Open
Affiliation(s)
- Nils Große Hokamp
- 1 Department of Radiology, University Hospitals Cleveland Medical Center, Cleveland, Ohio.,2 Department of Radiology, Case Western Reserve University, Cleveland, Ohio; and.,3 Institute for Diagnostic and Interventional Radiology, University Hospital Cologne, Cologne, Germany
| | - Amit Gupta
- 1 Department of Radiology, University Hospitals Cleveland Medical Center, Cleveland, Ohio
| | - Robert C Gilkeson
- 1 Department of Radiology, University Hospitals Cleveland Medical Center, Cleveland, Ohio
| |
Collapse
|
12
|
Sanghavi PS, Jankharia BG. Applications of dual energy CT in clinical practice: A pictorial essay. Indian J Radiol Imaging 2019; 29:289-298. [PMID: 31741598 PMCID: PMC6857256 DOI: 10.4103/ijri.ijri_241_19] [Citation(s) in RCA: 13] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/03/2019] [Revised: 09/15/2019] [Accepted: 10/08/2019] [Indexed: 12/18/2022] Open
Abstract
In dual-energy CT (DECT), two different x-ray spectra are used to acquire two image datasets of the same region, to allow the analysis of energy-dependent changes in the attenuation of different materials. Each type of material demonstrates a relatively specific change in attenuation between images obtained with a high-energy spectrum and those obtained with a low-energy spectrum. Based on the relatively specific change in attenuation with two different energies, material composition information can be obtained to allow tissue characterization. The DECT ability of material differentiation allows bone removal in various CT angiography studies and bone marrow edema depiction, while with material optimization, metal artefacts can be significantly reduced to almost nil. DECT allows material separation to differentiate uric acid crystals from calcium to determine the composition of urinary calculi and to diagnose gout. Using the DECT ability of material decomposition, iodine maps can be generated, which are useful in the evaluation of any enhancing lesion in the body without the need to obtain a plain scan and allow perfusion maps to be created in cases of pulmonary thromboembolism.
Collapse
|
13
|
Russo U, Maestroni U, Papapietro RV, Trunfio V, Ziglioli F, Ferretti S, Brunese L, Carrafiello G, De Filippo M. Imaging after radiofrequency ablation of renal tumors. Future Oncol 2018; 14:2915-2922. [DOI: 10.2217/fon-2017-0661] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/13/2022] Open
Abstract
The number of percutaneous radiofrequency ablation procedures performed for renal tumors is progressively increasing worldwide. Periodic imaging follow-up has the double role to guarantee the treatment efficacy over time and to early detect any possible complication. Tumor size reductions, as well as the appearance of the characteristic ‘halo sign’, are normal findings that represent good ablative outcomes. However the most reliable factor of ablation efficacy remains the total absence of contrast enhancing zones within the ablated area. The aim of this article is to illustrate the typical aspect of an effective radiofrequency ablation treatment, which are the imaging findings that may suggest the presence of residual tumoral tissue and which are the main early and late procedural complications.
Collapse
Affiliation(s)
- Umberto Russo
- Department of Medicine & Surgery, Unit of Radiologic Science, University of Parma, Maggiore Hospital, Via Gramsci 14, Parma, Italy
| | | | - Roberto Vito Papapietro
- Department of Medicine & Surgery, Unit of Radiologic Science, University of Parma, Maggiore Hospital, Via Gramsci 14, Parma, Italy
| | - Vincenzo Trunfio
- Department of Medicine & Surgery, Unit of Radiologic Science, University of Parma, Maggiore Hospital, Via Gramsci 14, Parma, Italy
| | | | | | - Luca Brunese
- Department of Medicine & Health Sciences, University of Molise, Campobasso, Italy
| | | | - Massimo De Filippo
- Department of Medicine & Surgery, Unit of Radiologic Science, University of Parma, Maggiore Hospital, Via Gramsci 14, Parma, Italy
| |
Collapse
|
14
|
Megibow AJ, Kambadakone A, Ananthakrishnan L. Dual-Energy Computed Tomography. Radiol Clin North Am 2018; 56:507-520. [DOI: 10.1016/j.rcl.2018.03.001] [Citation(s) in RCA: 24] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/14/2022]
|
15
|
Vernuccio F, Meyer M, Mileto A, Marin D. Use of Dual-Energy Computed Tomography for Evaluation of Genitourinary Diseases. Urol Clin North Am 2018; 45:297-310. [PMID: 30031456 DOI: 10.1016/j.ucl.2018.03.012] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/22/2022]
Abstract
Since its clinical inception a decade ago, dual-energy computed tomography has expanded the array of computed tomography imaging tools available to the practicing abdominal radiologist. Of note, diagnostic solutions for imaging-based evaluation of genitourinary diseases, foremost kidney calculi and renal tumors characterization, represent the apogee applications of dual-energy computed tomography in abdominal imaging. This article reviews clinical applications of dual-energy computed tomography for the assessment of genitourinary diseases.
Collapse
Affiliation(s)
- Federica Vernuccio
- Department of Radiology, Duke University Medical Center, Box 3808 Erwin Road, Durham, NC 27710, USA; Section of Radiology -Di.Bi.Med., University Hospital "Paolo Giaccone", University of Palermo, Via del Vespro 129, 90127, Palermo, Italy
| | - Mathias Meyer
- Department of Radiology, Duke University Medical Center, Box 3808 Erwin Road, Durham, NC 27710, USA
| | - Achille Mileto
- Department of Radiology, University of Washington School of Medicine, Box 357115, 1959 Northeast Pacific Street, Seattle, WA 98195, USA
| | - Daniele Marin
- Department of Radiology, Duke University Medical Center, Box 3808 Erwin Road, Durham, NC 27710, USA.
| |
Collapse
|
16
|
Multi-detector CT: Liver protocol and recent developments. Eur J Radiol 2017; 97:101-109. [PMID: 29153359 DOI: 10.1016/j.ejrad.2017.10.026] [Citation(s) in RCA: 17] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/29/2017] [Revised: 10/18/2017] [Accepted: 10/26/2017] [Indexed: 02/07/2023]
Abstract
Multi-detector computed tomography is today the workhorse in the evaluation of the vast majority of patients with known or suspected liver disease. Reasons for that include widespread availability, robustness and repeatability of the technique, time-efficient image acquisitions of large body volumes, high temporal and spatial resolution as well as multiple post-processing capabilities. However, as the technique employs ionizing radiation and intravenous iodine-based contrast media, the associated potential risks have to be taken into account. In this review article, liver protocols in clinical practice are discussed with emphasis on optimisation strategies. Furthermore, recent developments such as perfusion CT and dual-energy CT and their applications are presented.
Collapse
|
17
|
Marino MA, Silipigni S, Barbaro U, Mazziotti S, Sofia C, Mazzei MA, Ascenti G. Dual Energy CT Scanning in Evaluation of the Urinary Tract. CURRENT RADIOLOGY REPORTS 2017; 5:46. [DOI: 10.1007/s40134-017-0243-7] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/19/2022]
|
18
|
Abstract
Reignited by innovations in scanner engineering and software design, dual-energy computed tomography (CT) has come back into the clinical radiology arena in the last decade. Possibilities for noninvasive in vivo characterization of genitourinary disease, especially for renal stones and renal masses, have become the pinnacle offerings of dual-energy CT for body imaging in clinical practice. This article renders a state-of-the-art review on clinical applications of dual-energy CT in genitourinary imaging.
Collapse
Affiliation(s)
- Achille Mileto
- Department of Radiology, University of Washington School of Medicine, Box 357115, 1959 Northeast Pacific Street, Seattle, WA 98195, USA
| | - Daniele Marin
- Department of Radiology, Duke University Medical Center, Box 3808 Erwin Road, Durham, NC 27710, USA.
| |
Collapse
|
19
|
Bouda D, Lagadec M, Alba CG, Barrau V, Dioguardi Burgio M, Moussa N, Vilgrain V, Ronot M. Imaging review of hepatocellular carcinoma after thermal ablation: The good, the bad, and the ugly. J Magn Reson Imaging 2016; 44:1070-1090. [DOI: 10.1002/jmri.25369] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/17/2016] [Accepted: 06/16/2016] [Indexed: 12/11/2022] Open
Affiliation(s)
- Damien Bouda
- Radiology Department; Beaujon Hospital, University Hospitals Paris Nord Val de Seine, Assistance Publique-Hôpitaux de Paris, APHP; Clichy France
| | - Matthieu Lagadec
- Radiology Department; Beaujon Hospital, University Hospitals Paris Nord Val de Seine, Assistance Publique-Hôpitaux de Paris, APHP; Clichy France
| | - Carmela Garcia Alba
- Radiology Department; Beaujon Hospital, University Hospitals Paris Nord Val de Seine, Assistance Publique-Hôpitaux de Paris, APHP; Clichy France
| | - Vincent Barrau
- Radiology Department; Beaujon Hospital, University Hospitals Paris Nord Val de Seine, Assistance Publique-Hôpitaux de Paris, APHP; Clichy France
| | - Marco Dioguardi Burgio
- Radiology Department; Beaujon Hospital, University Hospitals Paris Nord Val de Seine, Assistance Publique-Hôpitaux de Paris, APHP; Clichy France
| | - Nadia Moussa
- Radiology Department; Beaujon Hospital, University Hospitals Paris Nord Val de Seine, Assistance Publique-Hôpitaux de Paris, APHP; Clichy France
| | - Valérie Vilgrain
- Radiology Department; Beaujon Hospital, University Hospitals Paris Nord Val de Seine, Assistance Publique-Hôpitaux de Paris, APHP; Clichy France
- University Paris Diderot; Sorbonne Paris Cité, INSERM UMR 1149 Paris France
| | - Maxime Ronot
- Radiology Department; Beaujon Hospital, University Hospitals Paris Nord Val de Seine, Assistance Publique-Hôpitaux de Paris, APHP; Clichy France
- University Paris Diderot; Sorbonne Paris Cité, INSERM UMR 1149 Paris France
| |
Collapse
|
20
|
De Cecco CN, Caruso D, Schoepf UJ, Wichmann JL, Ter Louw JR, Perry JD, Picard MM, Schaefer AR, Parker LW, Hardie AD. Optimization of window settings for virtual monoenergetic imaging in dual-energy CT of the liver: A multi-reader evaluation of standard monoenergetic and advanced imaged-based monoenergetic datasets. Eur J Radiol 2016; 85:695-9. [PMID: 26971410 DOI: 10.1016/j.ejrad.2016.01.007] [Citation(s) in RCA: 40] [Impact Index Per Article: 4.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/16/2015] [Revised: 01/13/2016] [Accepted: 01/16/2016] [Indexed: 01/14/2023]
Abstract
OBJECTIVES To evaluate optimal window settings for display of virtual monoenergetic reconstructions in third-generation dual-source, dual-energy computed tomography (DECT) of the liver. METHODS Twenty-nine subjects were prospectively evaluated with DECT in arterial (AP) and portal venous (PVP) phases. Three reconstructed datasets were calculated: standard linearly-blended (LB120), 70-keV standard virtual monoenergetic (M70), and 50-keV advanced image-based virtual monoenergetic (M50+). Two readers assessed optimal window settings (width and level, W/L), establishing a mean for each reconstruction which was used for a blinded assessment of liver lesions. RESULTS The optimal W/L for M50+ were significantly higher for both AP (W=429.3 ± 44.6 HU, L=129.4 ± 9.7 HU) and PVP (W=376.1 ± 14.2HU, L=146.6 ± 7.0 HU) than for LB120 (AP, W=215.9 ± 16.9 HU, L=82.3 ± 9.4 HU) (PVP, W=173.4 ± 8.9 HU, L=69.3 ± 6.0 HU) and M70 (AP, W=247.1 ± 22.2 HU, L=72.9 ± 6.8 HU) (PVP, W=232.0 ± 27.9 HU, L=91.6 ± 14.4 HU). Use of the optimal window setting for M50+ vs. LB120 resulted in higher sensitivity (AP, 100% vs. 86%; PVP, 96% vs. 63%). CONCLUSIONS Application of dedicated window settings results in improved liver lesion detection rates in advanced image-based virtual monoenergetic DECT when customized for arterial and portal venous phases.
Collapse
Affiliation(s)
- Carlo N De Cecco
- Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Medical University of South Carolina, 25 Courtenay Drive, Charleston, SC 29425, United States
| | - Damiano Caruso
- Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Medical University of South Carolina, 25 Courtenay Drive, Charleston, SC 29425, United States; Department of Radiological Sciences, Oncological and Pathological Sciences University of Rome "Sapienza", via Franco Faggiana 1668, 04100 Latina, Italy
| | - U Joseph Schoepf
- Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Medical University of South Carolina, 25 Courtenay Drive, Charleston, SC 29425, United States
| | - Julian L Wichmann
- Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Medical University of South Carolina, 25 Courtenay Drive, Charleston, SC 29425, United States; Department of Diagnostic and Interventional Radiology, University Hospital Frankfurt, Theodor-Stern-Kai 7, 60590 Frankfurt am Main, Germany
| | - Janet R Ter Louw
- Division of Abdominal Imaging, Department of Radiology and Radiological Science, Medical University of South Carolina, 25 Courtenay Drive, Charleston, SC 29425, United States
| | - Jonathan D Perry
- Division of Abdominal Imaging, Department of Radiology and Radiological Science, Medical University of South Carolina, 25 Courtenay Drive, Charleston, SC 29425, United States
| | - Melissa M Picard
- Division of Abdominal Imaging, Department of Radiology and Radiological Science, Medical University of South Carolina, 25 Courtenay Drive, Charleston, SC 29425, United States
| | - Amanda R Schaefer
- Division of Abdominal Imaging, Department of Radiology and Radiological Science, Medical University of South Carolina, 25 Courtenay Drive, Charleston, SC 29425, United States
| | - Leland W Parker
- Division of Abdominal Imaging, Department of Radiology and Radiological Science, Medical University of South Carolina, 25 Courtenay Drive, Charleston, SC 29425, United States
| | - Andrew D Hardie
- Division of Abdominal Imaging, Department of Radiology and Radiological Science, Medical University of South Carolina, 25 Courtenay Drive, Charleston, SC 29425, United States.
| |
Collapse
|