• Reference Citation Analysis
  • v
  • v
  • Find an Article
Find an Article PDF (5056980)   Today's Articles (1)
For: Akhtar M, Kyme A, Zhou V, Fulton R, Meikle S. An investigation of the challenges in reconstructing PET images of a freely moving animal. Australas Phys Eng Sci Med 2013;36:405-15. [PMID: 24122172 DOI: 10.1007/s13246-013-0222-0] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/27/2013] [Accepted: 09/24/2013] [Indexed: 10/26/2022]

Collapse
Number Cited by Other Article(s)
1
Kyme AZ, Fulton RR. Motion estimation and correction in SPECT, PET and CT. Phys Med Biol 2021;66. [PMID: 34102630 DOI: 10.1088/1361-6560/ac093b] [Citation(s) in RCA: 21] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/13/2020] [Accepted: 06/08/2021] [Indexed: 11/11/2022]
2
Estimation of and correction for finite motion sampling errors in small animal PET rigid motion correction. Med Biol Eng Comput 2018;57:505-518. [PMID: 30242596 PMCID: PMC6347657 DOI: 10.1007/s11517-018-1899-8] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/23/2018] [Accepted: 09/14/2018] [Indexed: 11/23/2022]

Motion correction of positron emission tomography (PET) scans of moving subjects can be performed by measuring the motion of the subject during the PET scan with an optical tracking camera. The motion tracking data obtained from the tracking camera is then used to correct the PET image reconstructions for motion. Due to finite time sampling of the motion data, the motion corrected reconstructions suffer from loss of spatial resolution. In the proposed method, a spatially variant deconvolution kernel is calculated from the motion tracking data, which is then used to correct the motion-corrected PET reconstructions for the blurring effect of the finite motion sampling through a Richardson-Lucy deconvolution.

3
Moskowitz AJ, Schöder H, Gavane S, Thoren KL, Fleisher M, Yahalom J, McCall SJ, Cadzin BR, Fox SY, Gerecitano J, Grewal R, Hamlin PA, Horwitz SM, Kumar A, Matasar M, Ni A, Noy A, Palomba ML, Perales MA, Portlock CS, Sauter C, Straus D, Younes A, Zelenetz AD, Moskowitz CH. Prognostic significance of baseline metabolic tumor volume in relapsed and refractory Hodgkin lymphoma. Blood 2017;130:2196-2203. [PMID: 28874350 PMCID: PMC5691245 DOI: 10.1182/blood-2017-06-788877] [Citation(s) in RCA: 104] [Impact Index Per Article: 13.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/09/2017] [Accepted: 08/14/2017] [Indexed: 12/11/2022]  Open
4
Miranda A, Staelens S, Stroobants S, Verhaeghe J. Fast and Accurate Rat Head Motion Tracking With Point Sources for Awake Brain PET. IEEE TRANSACTIONS ON MEDICAL IMAGING 2017;36:1573-1582. [PMID: 28207390 DOI: 10.1109/tmi.2017.2667889] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/06/2023]
5
Angelis GI, Kyme AZ, Ryder WJ, Fulton RR, Meikle SR. Attenuation correction for freely moving small animal brain PET studies based on a virtual scanner geometry. Phys Med Biol 2014;59:5651-66. [DOI: 10.1088/0031-9155/59/19/5651] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
PrevPage 1 of 1 1Next
© 2004-2025 Baishideng Publishing Group Inc. All rights reserved. 7041 Koll Center Parkway, Suite 160, Pleasanton, CA 94566, USA