1
|
Ye P, Zhao W, Shimomura T, Li KW, Haga A, Geng LS. Pixel-by-pixel correction of beam hardening artifacts by bowtie filter in fan-beam CT. Phys Med Biol 2024; 69:105020. [PMID: 38640915 DOI: 10.1088/1361-6560/ad40fa] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/04/2024] [Accepted: 04/19/2024] [Indexed: 04/21/2024]
Abstract
Objective. Beam hardening (BH) artifacts in computed tomography (CT) images originate from the polychromatic nature of x-ray photons. In a CT system with a bowtie filter, residual BH artifacts remain when polynomial fits are used. These artifacts lead to worse visuals, reduced contrast, and inaccurate CT numbers. This work proposes a pixel-by-pixel correction (PPC) method to reduce the residual BH artifacts caused by a bowtie filter.Approach. The energy spectrum for each pixel at the detector after the photons pass through the bowtie filter was calculated. Then, the spectrum was filtered through a series of water slabs with different thicknesses. The polychromatic projection corresponding to the thickness of the water slab for each detector pixel could be obtained. Next, we carried out a water slab experiment with a mono energyE= 69 keV to get the monochromatic projection. The polychromatic and monochromatic projections were then fitted with a 2nd-order polynomial. The proposed method was evaluated on digital phantoms in a virtual CT system and phantoms in a real CT machine.Main results. In the case of a virtual CT system, the standard deviation of the line profile was reduced by 23.8%, 37.3%, and 14.3%, respectively, in the water phantom with different shapes. The difference of the linear attenuation coefficients (LAC) in the central and peripheral areas of an image was reduced from 0.010 to 0.003cm-1and 0.007cm-1to 0 in the biological tissue phantom and human phantom, respectively. The method was also validated using CT projection data obtained from Activion16 (Canon Medical Systems, Japan). The difference in the LAC in the central and peripheral areas can be reduced by a factor of two.Significance. The proposed PPC method can successfully remove the cupping artifacts in both virtual and authentic CT images. The scanned object's shapes and materials do not affect the technique.
Collapse
Affiliation(s)
- Ping Ye
- School of Physics, Beihang University, Beijing 102206, People's Republic of China
| | - Wei Zhao
- School of Physics, Beihang University, Beijing 102206, People's Republic of China
- Hangzhou International Innovation Institute, Beihang University, Hangzhou 311115, People's Republic of China
| | - Taisei Shimomura
- Graduate School of Biomedical Sciences, Tokushima University, Tokushima 770-8503, Japan
| | - Kai-Wen Li
- Research and Development Department, CAS Ion Medical Technology Co., Ltd, Beijing 100190, People's Republic of China
| | - Akihiro Haga
- Graduate School of Biomedical Sciences, Tokushima University, Tokushima 770-8503, Japan
| | - Li-Sheng Geng
- School of Physics, Beihang University, Beijing 102206, People's Republic of China
- Beijing Key Laboratory of Advanced Nuclear Materials and Physics, Beihang University, Beijing 102206, People's Republic of China
- Peng Huanwu Collaborative Center for Research and Education, Beihang University, Beijing 100191, People's Republic of China
- Southern Center for Nuclear-Science Theory (SCNT), Institute of Modern Physics, Chinese Academy of Sciences, Huizhou 516000, People's Republic of China
| |
Collapse
|
2
|
Niu T, Xu L, Ren Q, Gao Y, Luo C, Teng Z, Du J, Ding M, Xie J, Han H, Jiang Y. UBES: Unified scatter correction using ultrafast Boltzmann equation solver for conebeam CT. Comput Biol Med 2024; 170:108045. [PMID: 38325213 DOI: 10.1016/j.compbiomed.2024.108045] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/06/2023] [Revised: 01/10/2024] [Accepted: 01/26/2024] [Indexed: 02/09/2024]
Abstract
A semi-analytical solution to the unified Boltzmann equation is constructed to exactly describe the scatter distribution on a flat-panel detector for high-quality conebeam CT (CBCT) imaging. The solver consists of three parts, including the phase space distribution estimator, the effective source constructor and the detector signal extractor. Instead of the tedious Monte Carlo solution, the derived Boltzmann equation solver achieves ultrafast computational capability for scatter signal estimation by combining direct analytical derivation and time-efficient one-dimensional numerical integration over the trajectory along each momentum of the photon phase space distribution. The execution of scatter estimation using the proposed ultrafast Boltzmann equation solver (UBES) for a single projection is finalized in around 0.4 seconds. We compare the performance of the proposed method with the state-of-the-art schemes, including a time-expensive Monte Carlo (MC) method and a conventional kernel-based algorithm using the same dataset, which is acquired from the CBCT scans of a head phantom and an abdominal patient. The evaluation results demonstrate that the proposed UBES method achieves comparable correction accuracy compared with the MC method, while exhibits significant improvements in image quality over learning and kernel-based methods. With the advantages of MC equivalent quality and superfast computational efficiency, the UBES method has the potential to become a standard solution to scatter correction in high-quality CBCT reconstruction.
Collapse
Affiliation(s)
- Tianye Niu
- Institute of Biomedical Engineering, Shenzhen Bay Laboratory, Shenzhen, Guangdong, China; Peking University Aerospace School of Clinical Medicine, Aerospace Center Hospital, Beijing, China.
| | - Lei Xu
- Department of Radiation Oncology, the First Affiliated Hospital of Xi'an Jiaotong University, Xi'an, Shaanxi, China
| | - Qing Ren
- Institute of Biomedical Engineering, Shenzhen Bay Laboratory, Shenzhen, Guangdong, China
| | - Yajuan Gao
- Department of Radiology, Peking University Third Hospital, Beijing, China
| | - Chen Luo
- Institute of Biomedical Engineering, Shenzhen Bay Laboratory, Shenzhen, Guangdong, China; School of Automation, Zhejiang Institute of Mechanical & Electrical Engineering, Hangzhou, Zhejiang, China
| | - Ze Teng
- Department of Radiology, National Cancer Center/National Clinical Research Center for Cancer/Cancer Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing, China
| | - Jichen Du
- Peking University Aerospace School of Clinical Medicine, Aerospace Center Hospital, Beijing, China
| | - Mingchao Ding
- Peking University Aerospace School of Clinical Medicine, Aerospace Center Hospital, Beijing, China
| | - Jiayi Xie
- Peking University Third Hospital, Beijing Key Laboratory of Magnetic Resonance Imaging Devices and Technology, Beijing, China; Department of Automatic, Tsinghua University, Beijing, China
| | - Hongbin Han
- Department of Radiology, National Cancer Center/National Clinical Research Center for Cancer/Cancer Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing, China; Beijing Key Laboratory of Magnetic Resonance Imaging Devices and Technology, Peking University Third Hospital, Beijing, China
| | - Yin Jiang
- Physics Department, Beihang University, Beijing, China
| |
Collapse
|
3
|
Cai M, Byrne M, Archibald-Heeren B, Metcalfe P, Rosenfeld A, Wang Y. Reducing axial truncation artifacts in iterative cone-beam CT for radiation therapy using a priori preconditioned information. Med Phys 2021; 48:7089-7098. [PMID: 34554587 DOI: 10.1002/mp.15248] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/02/2020] [Revised: 07/29/2021] [Accepted: 09/14/2021] [Indexed: 11/06/2022] Open
Abstract
PURPOSE Cone-beam computed tomography (CBCT) is increasingly utilized in radiation therapy for image guidance and adaptive applications. While iterative reconstruction algorithms have been shown to outperform traditional filtered back-projection methods in improving image quality and reducing imaging dose, they cannot handle data truncation in the axial view, which frequently occurs in the full-fan partial-trajectory acquisition mode. This proof-of-concept study presents a novel approach on truncation artifact reduction by utilizing a priori preconditioned information as the initial input for the iterative algorithm. METHODS Projections containing axial truncation were used for image reconstruction in extended axial field-of-view (AFOV) using the conjugate gradient least-squares (CGLS) algorithm. A priori information in the form of a planning fan-beam CT (FBCT) was repositioned in the expected CBCT imaging geometry, then further processed to dampen high-density features and convolved with a cubic Gaussian kernel to ensure differentiability for the gradient descent method. Anatomical and positional differences between the estimated and the actual imaging object were introduced to verify the efficacy of the proposed method. RESULTS Extending the reconstruction AFOV alone could partially reduce truncation artifact. Using a priori information directly resulted in ghosting artifact when there were anatomical and positional differences between the estimated and the actual imaging object. Using a priori preconditioned information was shown to effectively reduce truncation artifact and recover peripheral information. CONCLUSIONS Using a priori preconditioned information can effectively alleviate truncation artifact and assist recovery of peripheral information in iterative CBCT reconstruction.
Collapse
Affiliation(s)
- Meng Cai
- Icon Cancer Centre, Wahroonga, Australia.,Centre of Medical and Radiation Physics, University of Wollongong, Wollongong, Australia
| | | | | | - Peter Metcalfe
- Centre of Medical and Radiation Physics, University of Wollongong, Wollongong, Australia
| | - Anatoly Rosenfeld
- Centre of Medical and Radiation Physics, University of Wollongong, Wollongong, Australia
| | - Yang Wang
- Centre of Medical and Radiation Physics, University of Wollongong, Wollongong, Australia.,Icon Cancer Centre, Guangzhou, China
| |
Collapse
|