1
|
SIZE-specific dose estimate for lower-limb CT. Phys Eng Sci Med 2022; 45:1183-1191. [PMID: 36315380 DOI: 10.1007/s13246-022-01186-4] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/27/2022] [Accepted: 10/03/2022] [Indexed: 12/14/2022]
Abstract
The Computed Tomography Dose Index (CTDI) is an indicator for dose management in computed tomography (CT), but has limited use for patient dosimetry. To evaluate the patient dose, the size-specific dose estimate (SSDE), reported by the American Association of Physics in Medicine task groups 204, 220, and 293, must be calculated by the CTDIvol(z) displayed on the CT console, and the conversion factor f(D(z)) from the effective diameter (DEff) or water equivalent diameter (Dw). However, no reports have verified the appropriateness of using the 320-mm diameter phantom for dose assessment in CT examinations involving the lower limbs. Therefore, we validated a new method for evaluating the SSDE(z) of the lower limbs, using two 160-mm diameter phantoms instead of the 320-mm diameter phantom. The CTDIvol(z) obtained from Monte Carlo (MC) simulation study was reliable because they were almost the same as obtained in a dosimetry study. The conversion factor f (D (zl.l.)) for the lower limbs was evaluated based on the CTDIvol(z) obtained by MC simulation performed using two polymethyl methacrylate cylinder phantoms of 160-mm diameter. The MC simulation was performed by the International Commission on Radiological Protection publication 135 reference adult phantom and was used to evaluate the absorbed dose of the pelvis, thighs, knees, and ankles. The dose showing the greatest difference was the thighs, which was 8.3 mGy (16%) lower than the absorbed dose. Thus, the SSDE (zl.l.) could be estimated from the [Formula: see text] displayed on the CT scanner console.
Collapse
|
2
|
Kobayashi M, Nishihara Y, Haba T, Matsunaga Y, Minami K, Asada Y. SIZE-SPECIFIC DOSE ESTIMATES IN FETAL COMPUTED TOMOGRAPHY. RADIATION PROTECTION DOSIMETRY 2022; 198:339-348. [PMID: 35482288 DOI: 10.1093/rpd/ncac045] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/06/2021] [Revised: 03/05/2022] [Accepted: 03/13/2022] [Indexed: 06/14/2023]
Abstract
During fetal computed tomography (CT) imaging, because of differences in the pregnancy period and scanning conditions, different doses of radiation are absorbed by the fetus. We propose a correction coefficient for determining the fetal size-specific dose estimate (SSDE) from the CT dose index (CTDI) displayed on the console at tube voltages of 80-135 kVp. The CTDIs corresponding to pregnant women and fetuses were evaluated using a Monte Carlo (MC) simulation, and the ratio of these CTDIs was defined as the Fetus-factor. When the effective diameter of a fetus was approximately 10 cm, the Fetus-factor was 1.0. The estimated pregnant SSDE was multiplied by the Fetus-factor to estimate the fetal SSDE, which was compared with the fetal dose obtained by the MC simulation of the image of the fetal CT examination. The fetal dose could be estimated with an error of 31.5% in fetal examinations conducted using helical CT.
Collapse
Affiliation(s)
- Masanao Kobayashi
- Graduate School of Health Sciences, Fujita Health University, Toyoake, Aichi 470-1192, Japan
| | - Yusei Nishihara
- Department of Radiology, Fujita Health University Hospital, Toyoake, Aichi 470-1192, Japan
| | - Tomonobu Haba
- Graduate School of Health Sciences, Fujita Health University, Toyoake, Aichi 470-1192, Japan
| | - Yuta Matsunaga
- Department of Imaging, Nagoya Kyoritsu Hospital, Nagoya 454-0933, Japan
| | - Kazuyuki Minami
- Graduate School of Health Sciences, Fujita Health University, Toyoake, Aichi 470-1192, Japan
| | - Yasuki Asada
- Graduate School of Health Sciences, Fujita Health University, Toyoake, Aichi 470-1192, Japan
| |
Collapse
|
3
|
Matsunaga Y, Haba T, Kobayashi M, Suzuki S, Asada Y, Chida K. Novel pregnant model phantoms for measurement of foetal radiation dose in x-ray examinations. JOURNAL OF RADIOLOGICAL PROTECTION : OFFICIAL JOURNAL OF THE SOCIETY FOR RADIOLOGICAL PROTECTION 2021; 41:N12-N21. [PMID: 34233314 DOI: 10.1088/1361-6498/ac125c] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/06/2021] [Accepted: 07/07/2021] [Indexed: 06/13/2023]
Abstract
This study presents a comparison of novel pregnant model phantoms with a handmade phantom in terms of shape and radiation measurement points to determine which model is more suitable for measuring the foetal radiation dose during x-ray examinations. Novel pregnant model phantoms were constructed using an anthropomorphic phantom in combination with two differently-sized custom-made abdomen phantoms simulating pregnancy, which were constructed from a polyurethane resin. The size and shape of the polyurethane resin were designed based on abdominal sizes and shapes collected from the computed tomography examinations at 18 pregnant patients of one hospital. The handmade pregnant model phantom was constructed using an anthropomorphic phantom and a beach ball containing water. Compared with the handmade phantom, there were additional dose measurement points on the novel pregnant model phantoms. Our model phantoms improved upon the handmade phantom in terms of shape and radiation measurement points. We produced pregnant model phantoms that simulated the shapes and sizes of actual patients for the first time.
Collapse
Affiliation(s)
- Yuta Matsunaga
- Department of Imaging, Nagoya Kyoritsu Hospital, 1-172, Hokke, Nakagawa-ku, Nagoya, Aichi, Japan
- Department of Radiological Technology, Faculty of Health Sciences, Tohoku University Graduate School of Medicine, 2-1 Seiryo-machi, Aoba-ku, Sendai, Miyagi, Japan
| | - Tomonobu Haba
- Faculty of Radiological Technology, School of Health Science, Fujita Health University, 1-98 Dengakugakubo, Kutsukake-cho, Toyoake, Aichi, Japan
| | - Masanao Kobayashi
- Faculty of Radiological Technology, School of Health Science, Fujita Health University, 1-98 Dengakugakubo, Kutsukake-cho, Toyoake, Aichi, Japan
| | - Shoichi Suzuki
- Faculty of Radiological Technology, School of Health Science, Fujita Health University, 1-98 Dengakugakubo, Kutsukake-cho, Toyoake, Aichi, Japan
| | - Yasuki Asada
- Faculty of Radiological Technology, School of Health Science, Fujita Health University, 1-98 Dengakugakubo, Kutsukake-cho, Toyoake, Aichi, Japan
| | - Koichi Chida
- Department of Radiological Technology, Faculty of Health Sciences, Tohoku University Graduate School of Medicine, 2-1 Seiryo-machi, Aoba-ku, Sendai, Miyagi, Japan
| |
Collapse
|