1
|
Berrevoet F, Doerhoff C, Muysoms F, Hopson S, Muzi MG, Nienhuijs S, Kullman E, Tollens T, Schwartz M, Leblanc K, Velanovich V, Jørgensen LN. Open ventral hernia repair with a composite ventral patch - final results of a multicenter prospective study. BMC Surg 2019; 19:93. [PMID: 31311545 PMCID: PMC6633695 DOI: 10.1186/s12893-019-0555-z] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/11/2019] [Accepted: 07/03/2019] [Indexed: 01/08/2023] Open
Abstract
Background This study assessed clinical outcomes, including safety and recurrence, from the two-year follow-up of patients who underwent open ventral primary hernia repair with the use of the Parietex™ Composite Ventral Patch (PCO-VP). Methods A prospective single-arm, multicenter study of 126 patients undergoing open ventral hernia repair for umbilical and epigastric hernias with the PCO-VP was performed. Results One hundred twenty-six subjects (110 with umbilical hernia and 16 with epigastric hernia) with a mean hernia diameter of 1.8 cm (0.4–4.0) were treated with PCO-VP. One hundred subjects completed the two-year study. Cumulative hernia recurrence was 3.0% (3/101; 95%CI: 0.0–6.3%) within 24 months. Median Numeric Rating Scale pain scores improved from 2 [0–10] at baseline to 0 [0–3] at 1 month (P < 0.001) and remained low at 24 months 0 [0–6] (P < 0.001). 99% (102/103) of the patients were satisfied with their repair at 24 months postoperative. Conclusions The use of PCO-VP to repair primary umbilical and epigastric defects yielded a low recurrence rate, low postoperative and chronic pain, and high satisfaction ratings, confirming that PCO-VP is effective for small ventral hernia repair in the two-year term after implantation. Trial registration The study was registered publically at clinicaltrials.gov (NCT01848184 registered May 7, 2013).
Collapse
Affiliation(s)
- F Berrevoet
- Department of General and Hepatopancreatobiliary Surgery, Ghent University Hospital, Corneel Heymanslaan 10, 9000, Ghent, Belgium.
| | - C Doerhoff
- Surgicare of Missouri, Jefferson City, MO, USA
| | - F Muysoms
- Department of Surgery AZ Maria Middelares, Ghent, Belgium
| | - S Hopson
- Bon Secours Hernia Center, Mary Immaculate Hospital, Newport News, VA, USA
| | - M G Muzi
- University Hospital Tor Vergata, Rome, Italy
| | - S Nienhuijs
- Department of Surgery, Catharina Hospital, Eindhoven, Netherlands
| | - E Kullman
- HELSA Specialist Center, Linköping, Sweden
| | - T Tollens
- Imelda Hospital -General Surgery Imelda Hospital, Bonheiden, Belgium
| | - M Schwartz
- Monmouth Medical Center, Long Branch, NJ, USA
| | - K Leblanc
- Our Lady of Lakes Regional Medical Center, Baton Rouge, LA, USA
| | - V Velanovich
- Division of General Surgery, University of South Florida, Tampa General Hospital, Tampa, FL, USA
| | - L N Jørgensen
- Digestive Disease Center, Bispebjerg Hospital, University of Copenhagen, Copenhagen, Denmark
| |
Collapse
|
2
|
Gillion JF, Lepere M, Barrat C, Cas O, Dabrowski A, Jurczak F, Khalil H, Zaranis C. Two-year patient-related outcome measures (PROM) of primary ventral and incisional hernia repair using a novel three-dimensional composite polyester monofilament mesh: the SymCHro registry study. Hernia 2019; 23:767-781. [PMID: 30887379 PMCID: PMC6661060 DOI: 10.1007/s10029-019-01924-w] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/02/2018] [Accepted: 03/02/2019] [Indexed: 01/05/2023]
Abstract
Purpose This study examined patient-related outcome measures (PROMs) after repair of ventral primary or incisional hernias using Symbotex™ composite mesh (SCM), a novel three-dimensional collagen-coated monofilament polyester textile. Methods Pre-operative, peri-operative, and post-operative data were obtained from the French “Club Hernie” registry with 12- and 24-month follow-up. Results One-hundred consecutive patients (mean age 62.0 ± 13.7; 51% female) underwent repair of 105 hernias: primary (39/105, 37.1%, defect area 5.2 ± 5.6 cm2) and incisional (66/105, 62.9%, 31.9 ± 38.7.8 cm2). The mean BMI was 29.7 (± 5.6 kg/m2). American Society of Anesthesiologists classifications were I 39.4%, II 37.4% and III 23.2%. 75% had risk factors for healing and/or dissection. Of 38 primary repairs, 37 were completed laparoscopically (combined approach n = 1), and of 62 incisional hernia repairs, 40 were completed laparoscopically, and 20 by open repair (combined approach n = 2). Laparoscopic was quicker than open repair (36.2 ± 23.5 min vs. 67.4 ± 25.8, p < 0001). Before surgery, 86.3% of hernias were reported to cause discomfort/pain or dysesthesia. At 24 months (93 of 100 patients), 91 (97.8%) reported no lump and 81 (87.1%) no pain or discomfort. Of 91 patients, 86 (94.5%) rated their repair “good” or “excellent.” There were nine non-serious, surgeon-detected adverse events (ileus, n = 3; seroma, n = 6) and one hernia recurrence (6–12 months). Conclusions Compared to baseline, open and laparoscopic surgery improved PROMs 24 months after primary and incisional hernia repair. Minimal complications and recurrence support the long-term efficacy of SCM.
Collapse
Affiliation(s)
- J F Gillion
- Hôpital Privé d'Antony, 1 rue Velpeau, 92160, Antony, France.
| | - M Lepere
- Clinique Saint Augustin, Nantes, France
| | - C Barrat
- Hôpital J Verdier, Bondy, France
| | - O Cas
- Centre Médico-Chirurgical, Fondation Wallerstein, Arès, France
| | | | - F Jurczak
- Clinique mutualiste de l'estuaire, Saint-Nazaire, France
| | - H Khalil
- Chu-Hôpitaux De Rouen, Rouen, France
| | - C Zaranis
- Clinique du Mail, La Rochelle, France
| | | |
Collapse
|
3
|
Köckerling F, Lammers B. Open Intraperitoneal Onlay Mesh (IPOM) Technique for Incisional Hernia Repair. Front Surg 2018; 5:66. [PMID: 30406110 PMCID: PMC6206818 DOI: 10.3389/fsurg.2018.00066] [Citation(s) in RCA: 15] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/27/2018] [Accepted: 10/01/2018] [Indexed: 12/18/2022] Open
Abstract
In an Expert Consensus Guided by Systematic Review the panel agreed that for open elective incisional hernia repair sublay mesh location is preferred, but open intraperitoneal onlay mesh (IPOM) may be useful in certain settings. Accordingly, the available literature on the open IPOM technique was searched and evaluated. Material and Methods: A systematic search of the available literature was performed in July 2018 using Medline, PubMed, and the Cochrane Library. Forty-five publications were identified as relevant for the key question. Results: Compared to laparoscopic IPOM, the open IPOM technique was associated with significantly higher postoperative complication rates and recurrence rates. For the open IPOM with a bridging situation the postoperative complication rate ranges between 3.3 and 72.0% with a mean value of 20.4% demonstrating high variance, as did the recurrence rate of between 0 and 61.0% with a mean value of 12.6%. Only on evaluation of the upward-deviating maximum values and registry data is a trend toward better outcomes for the sublay technique demonstrated. Through the use of a wide mesh overlap, avoidance of dissection in the abdominal wall and defect closure it appears possible to achieve better outcomes for the open IPOM technique. Conclusion: Compared to the laparoscopic technique, open IPOM is associated with significantly poorer outcomes. For the sublay technique the outcomes are quite similar and only tendentially worse. Further studies using an optimized open IPOM technique are urgently needed.
Collapse
Affiliation(s)
- Ferdinand Köckerling
- Department of Surgery and Center for Minimally Invasive Surgery, Academic Teaching Hospital of Charité Medical School, Vivantes Hospital, Berlin, Germany
| | - Bernhard Lammers
- Department of Surgery I – Section Coloproctologie and Hernia Surgery, Lukas Hospital, Neuss, Germany
| |
Collapse
|
4
|
First Year Preliminary Results on the Use of a Monofilament Polyester Mesh With a Collagen Barrier for Primary and Incisional Ventral Hernia Repair. Int Surg 2018. [DOI: 10.9738/intsurg-d-17-00113.1] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022] Open
Abstract
Aim:
The SymCHro study objective is to assess patient outcomes and surgeon satisfaction following ventral hernia repair with a three-dimensional (3D) monofilament polyester mesh (Symbotex composite mesh) that contains an absorbable collagen barrier on 1 side to minimize tissue attachment.
Methods:
SymCHro is a multicenter observational study of 100 consecutive patients in the French Club Hernie registry who underwent primary and incisional ventral hernia repair with a Symbotex composite mesh. The primary objective is to assess recurrences and complications within 2 years of repair. This analysis reports 1-year results from the ongoing study.
Results:
A total of 105 hernias (37.1% primary, 62.9% incisional) in 100 patients were repaired by open or laparoscopic surgery. The patient follow-up rate at 1 year was 94%. A total of 6 (6.0%) low-grade seromas; 3 (3.0%) cases of low-grade transitory ileus; and 1 (1.0%) recurrence, which was asymptomatic but was repaired, occurred within 1-year follow-up. No serious adverse events were reported. All surgeons responded as satisfied with mesh flexibility and ease of insertion. Relative to baseline, patient pain reduced significantly at day 1 through month 3 postoperatively. At 1 year, 88.3% (83/94) patients assessed the hernia operation results as “good” or “excellent.”
Conclusion:
At this 1-year analysis, 94% of patients were followed up and experienced minimal pain and low complication rates, suggesting that Symbotex composite mesh provides an effective and safe repair for primary and incisional ventral hernias.
Collapse
|
5
|
Berrevoet F, Doerhoff C, Muysoms F, Hopson S, Muzi MG, Nienhuijs S, Kullman E, Tollens T, Schwartz MR, LeBlanc K, Velanovich V, Jørgensen LN. A multicenter prospective study of patients undergoing open ventral hernia repair with intraperitoneal positioning using the monofilament polyester composite ventral patch: interim results of the PANACEA study. MEDICAL DEVICES-EVIDENCE AND RESEARCH 2017; 10:81-88. [PMID: 28553149 PMCID: PMC5440003 DOI: 10.2147/mder.s132755] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022] Open
Abstract
Purpose This study assessed the recurrence rate and other safety and efficacy parameters following ventral hernia repair with a polyester composite prosthesis (Parietex™ Composite Ventral Patch [PCO-VP]). Patients and methods A single-arm, multicenter prospective study of 126 patients undergoing open ventral hernia repair with the PCO-VP was performed. Patient outcomes were assessed at discharge and at 10 days, 1, 6, 12, and 24 months postoperative. Results All patients had hernioplasty for umbilical (n = 110, 87.3%) or epigastric hernia (n = 16, 12.7%). Mean hernia diameter was 1.8 ± 0.8 cm. Mean operative time was 36.2 ±15.6 minutes, with a mean mesh positioning time of 8.1 ± 3.4 minutes. Surgeons reported satisfaction with mesh ease of use in 95% of surgeries. The cumulative hernia recurrence rate at 1 year was 2.8% (3/106). Numeric Rating Scale (NRS) pain scores showed improvement from 2.1 ± 2.0 at preoperative baseline to 0.5 ± 0.7 at 1 month postoperative (P < 0.001), and this low pain level was maintained at 12 months postsurgery (P < 0.001). The mean global Carolina’s Comfort Scale® (CCS) score improved postoperatively from 3.8 ± 6.2 at 1 month to 1.6 ± 3.5 at 6 months (P < 0.001). One patient was unsatisfied with the procedure. Conclusion This 1-year interim analysis using PCO-VP for primary umbilical and epigastric defects shows promising results in terms of mesh ease of use, postoperative pain, and patient satisfaction. Recurrence rate is low, but, as laparoscopic evaluation shows a need for patch repositioning in some cases, an accurate surgical technique remains of utmost importance.
Collapse
Affiliation(s)
- Frederik Berrevoet
- Department of General and Hepatopancreaticobiliary Surgery, Ghent University Hospital, Ghent, Belgium
| | - Carl Doerhoff
- General Surgery, Surgicare of Missouri, Jefferson City, MO, USA
| | - Filip Muysoms
- Department of Surgery, AZ Maria Middelares Ghent, Ghent, Belgium
| | - Steven Hopson
- Bon Secours Hernia Center, Mary Immaculate Hospital, Newport News, VA, USA
| | | | | | | | - Tim Tollens
- Imelda Hospital-General Surgery Imelda Hospital, Bonheiden, Belgium
| | | | - Karl LeBlanc
- Our Lady of Lakes Regional Medical Center, Baton Rouge, LA
| | - Vic Velanovich
- Tampa General Hospital, University of South Florida, Tampa, FL, USA
| | | |
Collapse
|
6
|
Long-term outcomes of 1326 laparoscopic incisional and ventral hernia repair with the routine suturing concept: a single institution experience. Hernia 2015; 20:101-10. [PMID: 26093891 DOI: 10.1007/s10029-015-1397-y] [Citation(s) in RCA: 78] [Impact Index Per Article: 7.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/15/2014] [Accepted: 06/07/2015] [Indexed: 12/18/2022]
Abstract
PURPOSE This retrospective chart analysis reports and assesses the long-term (beyond 10 years) safety and efficiency of a single institution's experience in 1326 laparoscopic incisional and ventral hernia repairs (LIVHR), defending the principle of the suturing defect (augmentation repair concept) prior to laparoscopic reinforcement with a composite mesh (IPOM Plus). This study aims to prove the feasibility and validity of IPOM Plus repair, among other concepts, as a well-justified treatment of incisional or ventral hernias, rendering a good long-term outcome result. METHODS A single institution's systematic retrospective review of 1326 LIVHR was conducted between the years 2000 and 2014. A standardized technique of routine closure of the defect prior to the intraperitoneal onlay mesh (IPOM) reinforcement was performed in all patients. The standardized technique of "defect closure" by laparoscopy approximating the linea alba under physiological tension was assigned by either the transparietal U reverse interrupted stitches or the extracorporeal closure in larger defects. All patients benefited from the implant Parietex composite mesh through an Intraperitoneal Onlay Mesh placement with transfacial suturing. RESULTS LIVHR was performed on 1326 patients, 52.57% female and 47.43% male. The majority of our patients were young (mean age 52.19 years) and obese (average BMI 32.57 kg/m2). The mean operating time was 70 min and hospital stay 2 days, with a mean follow-up of 78 months. On the overall early complications of 5.78%, we achieved over time the elimination of the dead space by routine closure of the defect, thus reducing seroma formation to 2.56%, with a low risk of infection <1%. Post-op sepsis occurred in only nine cases. Three secondary serosal breakdowns and two late perforations were re-operated, and three diabetic patients had infected hematomas, necessitating mesh removal. Through technical improvement in the suturing concept and our growing experience, we managed to reduce the incidence of transient pain to a low acceptable rate of 3.24% (VAS 5-7) that decreased to 2.56% on a chronic pain stage, which is comparable to the literature. On the overall rate of late complications of 10.74%, we noticed also that by reducing the dead space, the chronic pain, skin bulging, and rate of recurrence were reduced to, respectively, 2.56, 1.50, and 4.72%. One case of mortality was due to a tracheal stenosis, responsible for an acute respiratory syndrome. On a second-look follow-up of 126 patients (9.5%), 45.23% were adhesion free, 42.06% had minor adhesions classified as Müller I, and 12.69% had serosal adhesions classified as Müller II. CONCLUSION Our long series confirms the unexpected high rate of feasibility in the suturing concept or augmentation technique, and confers additional benefits to the conventional advantages of LIVHR in terms of reducing the overall morbidity, with a low rate of recurrences. Based on our experience and study, the current best indications for a successful LIVHR procedure should be tailored upon the limitations of the defect's width and proper patient selection, to restore adequately the optimal functionality of the abdominal muscles and provide better functional and cosmetic outcomes.
Collapse
|
7
|
Wiegmann B, Korossis S, Burgwitz K, Hurschler C, Fischer S, Haverich A, Kuehn C. In vitro comparison of biological and synthetic materials for skeletal chest wall reconstruction. Ann Thorac Surg 2015; 99:991-8. [PMID: 25586705 DOI: 10.1016/j.athoracsur.2014.09.040] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/05/2014] [Revised: 09/09/2014] [Accepted: 09/19/2014] [Indexed: 10/24/2022]
Abstract
BACKGROUND Various biological and synthetic materials have been proposed for use in skeletal chest wall reconstruction (SCWR). Because of the lack of studies allowing a direct comparison of SCWR materials, their clinical use often depends on the surgeon's preference and experience. The aim of this study was to analyze 6 synthetic and 3 biological materials frequently used in SCWR with respect to their cytotoxicity, bacterial adhesion, surface characteristics, and mechanical properties to facilitate data-driven decisions. METHODS The effect of the SCWR materials and their extracts on the metabolism of human skeletal muscle cells (SkMCs), dermal fibroblasts, adipose cells, and osteoblasts was analyzed in vitro. Bacterial adhesion was quantified by incubating samples in bacterial suspensions (Staphylococcus epidermidis, S aureus, and Escherichia coli), followed by counting colony-forming units and performing scanning electron microscopy. Moreover, the mechanical properties of the materials were analyzed under uniaxial tensile loading to failure. RESULTS The metabolism of all cell types seeded on the SCWR materials was reduced compared with untreated cells. With the exception of Vypro (Ethicon, Somerville, NJ), whose extracts significantly reduced fibroblast viability, no cytotoxic leachable substances were detected. Biological materials were less cytotoxic compared with synthetic ones, but they demonstrated increased bacterial adhesion. Synthetic materials demonstrated higher elongation to failure than did biological materials. CONCLUSIONS Biological and synthetic SCWR materials showed significant differences in their cytotoxicity, bacterial adhesion, and biomechanical properties, suggesting that they may be used for different indications in SCWR. Further comparable in vivo studies are needed to analyze their performance in different indications of clinical application.
Collapse
Affiliation(s)
- Bettina Wiegmann
- Department of Cardiothoracic, Transplantation, and Vascular Surgery, Hannover Medical School, Hannover, Germany; Lower Saxony Centre for Biomedical Engineering, Implant Research and Development, Hannover, Germany
| | - Sotirios Korossis
- Lower Saxony Centre for Biomedical Engineering, Implant Research and Development, Hannover, Germany
| | - Karin Burgwitz
- Department of Cardiothoracic, Transplantation, and Vascular Surgery, Hannover Medical School, Hannover, Germany; CrossBIT Research Center for Biocompatibility and Immunology of Medical Implants, Hannover Medical School, Hannover, Germany
| | - Christof Hurschler
- Orthopedic Clinic, Laboratory for Biomechanics and Kinematics, Hannover Medical School, Hannover, Germany
| | - Stefan Fischer
- Department of Cardiothoracic, Transplantation, and Vascular Surgery, Hannover Medical School, Hannover, Germany
| | - Axel Haverich
- Department of Cardiothoracic, Transplantation, and Vascular Surgery, Hannover Medical School, Hannover, Germany; CrossBIT Research Center for Biocompatibility and Immunology of Medical Implants, Hannover Medical School, Hannover, Germany; Lower Saxony Centre for Biomedical Engineering, Implant Research and Development, Hannover, Germany
| | - Christian Kuehn
- Department of Cardiothoracic, Transplantation, and Vascular Surgery, Hannover Medical School, Hannover, Germany; CrossBIT Research Center for Biocompatibility and Immunology of Medical Implants, Hannover Medical School, Hannover, Germany.
| |
Collapse
|
8
|
Deerenberg EB, Timmermans L, Hogerzeil DP, Slieker JC, Eilers PHC, Jeekel J, Lange JF. A systematic review of the surgical treatment of large incisional hernia. Hernia 2014; 19:89-101. [PMID: 25380560 DOI: 10.1007/s10029-014-1321-x] [Citation(s) in RCA: 94] [Impact Index Per Article: 8.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/27/2013] [Accepted: 10/26/2014] [Indexed: 01/12/2023]
Abstract
PURPOSE Incisional hernia (IH) is one of the most frequent postoperative complications. Of all patients undergoing IH repair, a vast amount have a hernia which can be defined as a large incisional hernia (LIH). The aim of this study is to identify the preferred technique for LIH repair. METHODS A systematic review of the literature was performed and studies describing patients with IH with a diameter of 10 cm or a surface of 100 cm2 or more were included. Recurrence hazards per year were calculated for all techniques using a generalized linear model. RESULTS Fifty-five articles were included, containing 3,945 LIH repairs. Mesh reinforced techniques displayed better recurrence rates and hazards than techniques without mesh reinforcement. Of all the mesh techniques, sublay repair, sandwich technique with sublay mesh and aponeuroplasty with intraperitoneal mesh displayed the best results (recurrence rates of <3.6%, recurrence hazard <0.5% per year). Wound complications were frequent and most often seen after complex LIH repair. CONCLUSIONS The use of mesh during LIH repair displayed the best recurrence rates and hazards. If possible mesh in sublay position should be used in cases of LIH repair.
Collapse
Affiliation(s)
- E B Deerenberg
- Department of Surgery, Erasmus University Medical Center Rotterdam, ErasmusMC, Room Ee-173, Postbus 2400, 3000 CA, Rotterdam, The Netherlands,
| | | | | | | | | | | | | |
Collapse
|
9
|
Outcomes of open intraperitoneal incisional hernia repair based on patient-reported outcomes. Hernia 2013; 18:47-55. [PMID: 23292369 DOI: 10.1007/s10029-012-1041-z] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/26/2012] [Accepted: 12/27/2012] [Indexed: 10/27/2022]
Abstract
PURPOSE The outcomes of open incisional hernia repair from the patients' point of view have variations over time, and only continuous follow-up would reflect the real outcomes. The purpose of this study is to validate a standard measurement instrument in the form of a questionnaire to report the evolutionary outcomes of a specific open technique to repair incisional hernias. METHODS Prospective study follows up a cohort of 82 consecutive patients submitted to elective intraperitoneal open hernioplasty of midline incisional hernias. The follow-up consisted in an interview and physical examination 30 days after surgery, at 6 months, 1 year, 2 years, 3 years, and 4 years. Primary outcome measure was reporting the outcomes of hernia repair according to a standardized scale obtained from a questionnaire. RESULTS There was no correlation between complications suffered by patients and score results (p = 0.722). The length of hospital stay was 6.5 ± 4.3 days, and a prolonged hospital stay was related to complications (p = 0.002) and did not influence the score results (p = 0.365). The final score demonstrated that patients had a very good impression on this procedure 1 month after surgery (p = 0.003). This impression shifted to an excellent perception 1 year after surgery remaining similar until the last control (p < 0.0001). CONCLUSIONS In this series, the intraperitoneal hernioplasty was a procedure associated with minor morbidity and without recurrences 4 years after the operation. The outcomes from the patients' point of view were excellent 1 year after the procedure with a tendency to improve in the long term.
Collapse
|
10
|
Short- and mid-term outcome after laparoscopic repair of large incisional hernia. Hernia 2012; 17:567-72. [PMID: 23269400 DOI: 10.1007/s10029-012-1026-y] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/28/2011] [Accepted: 12/08/2012] [Indexed: 10/27/2022]
Abstract
PURPOSE To compare the outcome after laparoscopic incisional and ventral herniorrhaphy (LIVH) for fascial defect larger or equal than 15 cm in width with the outcome after LIVH in patients with hernia defect smaller than 15 cm. METHODS From 2003 through 2010, 350 patients were submitted to LIVH. In 70 cases, hernia defect was ≥15 cm in width and in 280 was <15 cm. Incisional hernias were often recurrent, double or multiorificial. In the group of larger hernias, the rate of obesity, recurrent hernia and multiorificial hernia was 27.1, 24.2 and 12.8 %, respectively, and in the group of smaller hernias 27.3, 16.1 and 2.8 %, respectively. Patients were interviewed using McGill pain score test to measure postoperative quality of life (QoL) in the mid-term. RESULTS LIVH for hernia ≥15 cm required longer surgical time (p = 0.034) and postoperative hospital stay (p = 0.0001). Besides, there were higher rate of postoperative prolonged ileus (p = 0.035) and polmonitis (p = 0.001). Overall recurrence rate was 2.6, 8.6 % for larger and 1.1 % for smaller incisional hernias, p = 0.045. Mc Gill pain test revealed no significant difference in the two groups of patients in postoperative QoL within 36 months. CONCLUSIONS Laparoscopic approach seems safe and effective even to repair large incisional hernia, the rate of recurrence was higher, but acceptable, if compared to smaller hernias. To the best of our knowledge, this is the largest reported series of incisional hernias ≥15 cm managed by laparoscopy.
Collapse
|
11
|
Compound Repair of Intraperitoneal Onlay Mesh Associated With the Sublay Technique for Giant Lower Ventral Hernia. Ann Plast Surg 2012; 69:192-6. [DOI: 10.1097/sap.0b013e3182250dfb] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
|
12
|
Yang F. Radical tumor excision and immediate abdominal wall reconstruction in patients with aggressive neoplasm compromised full-thickness lower abdominal wall. Am J Surg 2012; 205:15-21. [PMID: 22794707 DOI: 10.1016/j.amjsurg.2012.04.007] [Citation(s) in RCA: 19] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/13/2011] [Revised: 04/06/2012] [Accepted: 04/06/2012] [Indexed: 10/28/2022]
Abstract
BACKGROUND Radical tumor resection and immediate lower abdominal wall reconstruction in patients with aggressive neoplasm invading full-thickness abdominal wall are challenging because of their close proximity and possible invasion to bone and great vessels, as well as consequent giant defect. METHODS Data on 16 patients were reviewed retrospectively. Radical neoplasm resection and immediate abdominal wall reconstruction using the combined technique of intraperitoneal mesh placement, sublay technique, pedicled great omentum flap, and rotation skin graft were performed. RESULTS Sixteen patients underwent radical abdominal wall neoplasm resection, achieving clear margin of >3 cm. The mean size of consequent giant defect was 226.5 ± 65.5 cm(2), with a mean polypropylene mesh size of 160.7 ± 40.5 cm(2) and a mean compound mesh size of 330.8 ± 100.2 cm(2). Sixteen patients had a mean follow-up duration of 32.5 ± 12.5 months. Four patients developed incisional infections, and 1 patient died of several metastatic lesions 24 months postoperatively. No ventral hernia and abdominal wall recurrence were observed. CONCLUSIONS Radical neoplasm resection and immediate abdominal wall reconstruction are appropriate for patients with aggressive neoplasm in the lower abdominal wall.
Collapse
Affiliation(s)
- Fei Yang
- Department of General Surgery, 1st Affiliated Hospital of PLA General Hospital, Beijing, China.
| |
Collapse
|
13
|
Pre-operative progressive pneumoperitoneum for repair of a large incisional hernia. Updates Surg 2012; 65:165-8. [PMID: 22392573 DOI: 10.1007/s13304-012-0134-7] [Citation(s) in RCA: 11] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/18/2011] [Accepted: 01/30/2012] [Indexed: 10/28/2022]
Abstract
Large incisional hernias are difficult to treat surgically because of the post-operative respiratory complications and abdominal compartment syndrome. Pre-operative progressive pneumoperitoneum is a technique which has been used in such cases. We describe a case of a large incisional hernia, where this technique was employed by objectively calculating abdominal and hernial sac volumes on the basis of computerized tomography scan of abdomen with a satisfactory outcome. A review of literature and issues involved in pre-operative progressive pneumoperitoneum have been discussed.
Collapse
|
14
|
Rieger UM, Petschke F, Djedovic G, Engelhardt TO, Biebl M, Pierer G. Abdominal wall reconstruction after extensive abdominal wall necrosis resulting from chevron incision for liver transplant and subsequent Y-shaped incision for re-transplantation--clinical experience and literature review. J Plast Reconstr Aesthet Surg 2011; 65:e71-3. [PMID: 22115912 DOI: 10.1016/j.bjps.2011.11.021] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/12/2011] [Revised: 09/24/2011] [Accepted: 11/08/2011] [Indexed: 01/18/2023]
Abstract
Extensive Abdominal wall necrosis is a devastating complication. In visceral transplant patients a quick and easy to perform reconstructive technique may be crucial for patient survival. Based on a clinical case a literature review is performed including a thorough analysis of abdominal wall perfusion and surgical options for defect closure are presented and critically appraised.
Collapse
Affiliation(s)
- Ulrich M Rieger
- Department of Plastic, Reconstructive and Aesthetic Surgery, Medical University Innsbruck (MUI), Innsbruck, Austria.
| | | | | | | | | | | |
Collapse
|
15
|
Moreno-Egea A, Carrillo-Alcaraz A, Aguayo-Albasini JL. Is the outcome of laparoscopic incisional hernia repair affected by defect size? A prospective study. Am J Surg 2011; 203:87-94. [PMID: 21788002 DOI: 10.1016/j.amjsurg.2010.11.017] [Citation(s) in RCA: 39] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/08/2010] [Revised: 11/16/2010] [Accepted: 11/16/2010] [Indexed: 11/16/2022]
Abstract
BACKGROUND This study was performed to determine if defect size after laparoscopic incisional hernia repair is predictive of recurrence during the long-term follow-up evaluation. METHODS We performed a prospective clinical study on 310 patients who underwent laparoscopic incisional hernia repair to identify predictable risk factors for hernia recurrence. Univariate and multivariate Cox regression analysis were used. The defect size was analyzed with curve receiver operating characteristic curve. RESULTS The overall recurrence rate was 6% after an average follow-up period of 60 months. On univariate analysis of the defect size (categories: <10 cm, 10-12 cm, and >15 cm), obesity, previous repairs, hernia location, surgical time, hospital stay, morbidity, and recurrences were significantly different (P < .001). By multivariate analysis, only obesity and defect size were independent prognostic factors (P < .001). CONCLUSIONS The predictive value of defect size is shown. Patients with large defects have a higher risk of recurrence. Our study recommends reserving the laparoscopic technique for hernias not exceeding 10 cm in size, where it can be put to better use.
Collapse
Affiliation(s)
- Alfredo Moreno-Egea
- Abdominal Wall Unit, Department of Surgery, J.M. Morales Meseguer Hospital, Avda. Primo de Rivera 7, 5°D (Edf. Berlín), 30008 Murcia, Spain.
| | | | | |
Collapse
|