1
|
Xu X, Chang S, Zhang X, Hou T, Yao H, Zhang S, Zhu Y, Cui X, Wang X. Fabrication of a controlled-release delivery system for relieving sciatica nerve pain using an ultrasound-responsive microcapsule. Front Bioeng Biotechnol 2022; 10:1072205. [PMID: 36507268 PMCID: PMC9729723 DOI: 10.3389/fbioe.2022.1072205] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/17/2022] [Accepted: 11/07/2022] [Indexed: 11/25/2022] Open
Abstract
Lidocaine, a potent local anesthetic, is clinically used in nerve block and pain management. However, due to its short half-life, repeated administration is required. For this reason, here we designed and prepared a lidocaine-encapsulated polylactic acid-glycolic acid (Lidocaine@PLGA) microcapsule with ultrasound responsiveness to relieve the sciatica nerve pain. With a premixed membrane emulsification strategy, the fabricated lidocaine-embedded microcapsules possessed uniform particle size, good stability, injectability, and long-term sustained release both in vitro and in vivo. More importantly, Lidocaine@PLGA microcapsules had the function of ultrasonic responsive release, which made the drug release controllable with the effect of on-off administration. Our research showed that using ultrasound as a trigger switch could promote the rapid release of lidocaine from the microcapsules, achieving the dual effects of long-term sustained release and short-term ultrasound-triggered rapid release, which can enable the application of ultrasound-responsive Lidocaine@PLGA microcapsules to nerve root block and postoperative pain relief.
Collapse
Affiliation(s)
- Xiong Xu
- Department of Orthopaedics, The 8th Medical Center of PLA General Hospital, Beijing, China,Department of Graduate, Hebei North University, Zhangjiakou, China,Beijing National Laboratory for Molecular Sciences, Institute of Chemistry, Chinese Academy of Sciences, Beijing, China
| | - Shuai Chang
- Orthopedics Department, Peking University Third Hospital, Beijing, China
| | - Xiaoyi Zhang
- Beijing National Laboratory for Molecular Sciences, Institute of Chemistry, Chinese Academy of Sciences, Beijing, China
| | - Taotao Hou
- Department of Graduate, Hebei North University, Zhangjiakou, China
| | - Hui Yao
- Department of Orthopedics, Eye Hospital, China Academy of Chinese Medical Sciences, Beijing, China
| | - Shusheng Zhang
- ShenYang Tiantai Remote Medical Tech Development Co., Ltd., Shenyang, China
| | - Yuqi Zhu
- Department of Orthopedics, Eye Hospital, China Academy of Chinese Medical Sciences, Beijing, China,Correspondence: Yuqi Zhu, ; Xu Cui, ; Xing Wang,
| | - Xu Cui
- Department of Orthopaedics, The 8th Medical Center of PLA General Hospital, Beijing, China,Correspondence: Yuqi Zhu, ; Xu Cui, ; Xing Wang,
| | - Xing Wang
- Beijing National Laboratory for Molecular Sciences, Institute of Chemistry, Chinese Academy of Sciences, Beijing, China,Correspondence: Yuqi Zhu, ; Xu Cui, ; Xing Wang,
| |
Collapse
|
2
|
Abdeltawab H, Svirskis D, Hill AG, Sharma M. Increasing the Hydrophobic Component of Poloxamers and the Inclusion of Salt Extend the Release of Bupivacaine from Injectable In Situ Gels, While Common Polymer Additives Have Little Effect. Gels 2022; 8:gels8080484. [PMID: 36005085 PMCID: PMC9407117 DOI: 10.3390/gels8080484] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/13/2022] [Revised: 07/18/2022] [Accepted: 07/28/2022] [Indexed: 11/16/2022] Open
Abstract
Various strategies have been applied to reduce the initial burst of drug release and sustain release from poloxamer-based thermoresponsive gels. This work focussed on investigating different formulation approaches to minimise the initial burst of release and sustain the release of the small hydrophilic drug bupivacaine hydrochloride from poloxamer-based thermoresponsive gels. Various in situ gel formulations were prepared by varying the polypropylene oxide (PPO)/polyethylene oxide (PEO) ratio and by adding additives previously described in the literature. It was observed that increasing the PPO/PEO ratio from 0.28 to 0.30 reduced the initial burst release from 17.3% ± 1.8 to 9.1% ± 1.2 during the first six hours and extended the release profile from 10 to 14 days. Notably, the inclusion of sodium chloride (NaCl 0.4% w/w) further reduced the initial burst release to 1.8% ± 1.1 over the first 6 h. Meanwhile, physical blending with additive polymers had a negligible effect on the burst release and overall release profile. The findings suggest that extended release of bupivacaine hydrochloride, with reduced initial burst release, can be achieved simply by increasing the PPO/PEO ratio and the inclusion of NaCl.
Collapse
Affiliation(s)
- Hani Abdeltawab
- School of Pharmacy, Faculty of Medical & Health Sciences, The University of Auckland, Auckland 1023, New Zealand; (H.A.); (D.S.)
| | - Darren Svirskis
- School of Pharmacy, Faculty of Medical & Health Sciences, The University of Auckland, Auckland 1023, New Zealand; (H.A.); (D.S.)
| | - Andrew G. Hill
- Department of Surgery, South Auckland Clinical Campus, The University of Auckland, Middlemore Hospital, Auckland 2025, New Zealand;
| | - Manisha Sharma
- School of Pharmacy, Faculty of Medical & Health Sciences, The University of Auckland, Auckland 1023, New Zealand; (H.A.); (D.S.)
- Correspondence: ; Tel.: +64-9-373-7599 (ext. 81830); Fax: +64-9-367-7192
| |
Collapse
|
3
|
Injectable In Situ Gelling System for Sustained Nicotine Delivery as a Replacement Therapy for Smoking Cessation. Gels 2022; 8:gels8020114. [PMID: 35200495 PMCID: PMC8872261 DOI: 10.3390/gels8020114] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/06/2021] [Revised: 02/01/2022] [Accepted: 02/10/2022] [Indexed: 02/01/2023] Open
Abstract
Nicotine replacement therapy (NRT) is widely used to limit the withdrawal symptoms associated with cigarette smoking cessation. However, the available NRT formulations are limited by their short release profiles, requiring frequent administrations along with local side effects. Thus, the objective of this study is to develop an NRT formulation that offers prolonged, sustained nicotine release. Thermoresponsive in situ gelling systems containing nicotine were prepared using poloxamer 407 (P407) and poloxamer 188 (P188). The system was optimized using a three-factor, two-level full factorial design (23). A formulation composed of P407 (20% w/w), P188 (5% w/w), and loaded with nicotine (0.5% w/w) exhibited sol-to-gel transition at a suitable temperature close to physiological temperature (30 °C). The rheological analysis demonstrated a Newtonian-like flow at room temperature, suggesting ease of administration via injection, and semisolid gel status at physiological temperature. The optimized formulation successfully sustained nicotine in vitro release over 5 days following single administration. The findings suggest that poloxamer based in situ gelling systems are promising platforms to sustain the release of nicotine.
Collapse
|
4
|
Sustained Delivery of Lactoferrin Using Poloxamer Gels for Local Bone Regeneration in a Rat Calvarial Defect Model. MATERIALS 2021; 15:ma15010212. [PMID: 35009359 PMCID: PMC8745849 DOI: 10.3390/ma15010212] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 10/28/2021] [Revised: 12/23/2021] [Accepted: 12/25/2021] [Indexed: 01/02/2023]
Abstract
Lactoferrin (LF) is a multifunctional milk glycoprotein that promotes bone regeneration. Local delivery of LF at the bone defect site is a promising approach for enhancement of bone regeneration, but efficient systems for sustained local delivery are still largely missing. The aim of this study was to investigate the potential of the poloxamers for sustained delivery of LF to enhance local bone regeneration. The developed LF/poloxamer formulations were liquid at room temperature (20 °C) transforming to a sustained releasing gel depot at body temperature (37 °C). In vitro release studies demonstrated an initial burst release (~50%), followed by slower release of LF for up to 72 h. Poloxamer, with and without LF, increased osteoblast viability at 72 h (p < 0.05) compared to control, and the immune response from THP-1 cells was mild when compared to the suture material. In rat calvarial defects, the LF/poloxamer group had lower bone volume than the controls (p = 0.0435). No difference was observed in tissue mineral density and lower bone defect coverage scores (p = 0.0267) at 12 weeks after surgery. In conclusion, LF/poloxamer formulations support cell viability and do not induce an unfavourable immune response; however, LF delivery via the current formulation of LF200/poloxamer gel did not demonstrate enhanced bone regeneration and was not compatible with the rat calvarial defect model.
Collapse
|
5
|
Abdeltawab H, Svirskis D, Boyd BJ, Hill A, Sharma M. Injectable thermoresponsive gels offer sustained dual release of bupivacaine hydrochloride and ketorolac tromethamine for up to two weeks. Int J Pharm 2021; 604:120748. [PMID: 34051318 DOI: 10.1016/j.ijpharm.2021.120748] [Citation(s) in RCA: 17] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/12/2021] [Revised: 05/23/2021] [Accepted: 05/24/2021] [Indexed: 01/26/2023]
Abstract
Bupivacaine and ketorolac are commonly used in combination to reduce perioperative pain. This study aimed to develop and characterize an injectable system that offers simultaneous and prolonged release of bupivacaine and ketorolac. Formulations were prepared using poloxamer 407 with increasing concentrations of poloxamer 188 and sodium chloride. Small Angle X-ray Scattering (SAXS) experiments demonstrated that the poloxamers form gels with a cubic lattice arrangement regardless of the matrix composition, whereas the system porosity is driven by poloxamers concentration. Drug loading slightly reduced the intermicellar spacing. Fourier transform infrared spectroscopy and thermal analysis suggested electrostatic interactions between the loaded drugs and poloxamers. Mechanical and rheological studies confirmed the formulations exhibit Newtonian-like flow at room temperature followed by a transition to a viscous gel at body temperature. Importantly, the developed formulations demonstrated steady and sustained release of both bupivacaine and ketorolac over two weeks. Sodium chloride reduced the initial burst release over the first six hours for BH, from 8.6 ± 0.18% to 1.6 ± 0.11%, and KT, from 7.7 ± 0.27% to 1.5 ± 0.10%. Hence, poloxamer-based thermoresponsive gelling systems are promising delivery platforms for the sustained delivery of bupivacaine and ketorolac, with potential clinical benefits for managing perioperative pain.
Collapse
Affiliation(s)
- Hani Abdeltawab
- School of Pharmacy, Faculty of Medical & Health Sciences, The University of Auckland, New Zealand
| | - Darren Svirskis
- School of Pharmacy, Faculty of Medical & Health Sciences, The University of Auckland, New Zealand
| | - Ben J Boyd
- Drug Delivery, Disposition and Dynamics and ARC Centre of Excellence in Convergent Bio-Nano Science and Technology, Monash Institute of Pharmaceutical Sciences, Monash University (Parkville Campus), 381 Royal Parade, Parkville, VIC 3052, Australia
| | - Andrew Hill
- Department of Surgery, School of Medicine, The University of Auckland, Middlemore Hospital, Auckland, New Zealand
| | - Manisha Sharma
- School of Pharmacy, Faculty of Medical & Health Sciences, The University of Auckland, New Zealand.
| |
Collapse
|
6
|
Abou-ElNour M, Soliman ME, Skouras A, Casettari L, Geneidi AS, Ishak RAH. Microparticles-in-Thermoresponsive/Bioadhesive Hydrogels as a Novel Integrated Platform for Effective Intra-articular Delivery of Triamcinolone Acetonide. Mol Pharm 2020; 17:1963-1978. [PMID: 32271590 DOI: 10.1021/acs.molpharmaceut.0c00126] [Citation(s) in RCA: 21] [Impact Index Per Article: 4.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/18/2022]
Abstract
Intra-articular (IA) injection of thermoresponsive hydrogels coupled with microparticles (MPs) possess the benefit of sustaining the anti-inflammatory drug effect within the joint cavity for rheumatoid arthritis treatment. Star-shaped thermoresponsive poly(polyethylene glycol) methacrylate [Poly(PEGMA)] copolymers were synthesized using free radical polymerization technique and fully characterized. Triamcinolone acetonide (TA)-loaded PLA/mPEG-PDL MPs, previously optimized, were integrated into the synthesized copolymer solutions at various concentrations and tested for their gelation temperatures. The MPs-in-hydrogel formulations were characterized using scanning electron microscope (SEM), viscosity measurements, ex vivo bioadhesion, and in vitro release studies. The anti-inflammatory effect of integrated systems was assessed in adjuvant-induced monoarthritic rat knee joints and compared to Kenacort and TA-loaded MPs. Two copolymers were successfully synthesized; G-1 = poly(PEGMA188-ME-co-PEGMA475-ME) and G-2 = poly(PEGMA246-EE-co-PEGMA475-ME). Using the tube inversion technique, the gel formation was found dependent on copolymer concentration. An irreversible aggregation was obtained at copolymer concentrations ≤10% (w/v), while a gel was formed at 20 and 30% (w/v) of both copolymers upon increasing temperature. The MP-hydrogel formulations were optimized at 20 and 30% (w/v) of G-1 and G-2 with gelation temperatures of 33 and 37 °C, respectively. SEM images revealed the porous microstructures of hydrogels and their adsorption on MP surfaces. The integrated formulas showed pseudoplastic behaviors, while the bioadhesion study confirmed their bioadhesiveness on excised cartilage. The in vitro release study confirmed drug sustainment from MPs-hydrogels compared to MPs. In vivo studies proved the superiority of MP-in-hydrogels in treatment of induced arthritis, relative to Kenacort and MPs alone, suggesting the applicability of this integrated platform in IA drug delivery.
Collapse
Affiliation(s)
- May Abou-ElNour
- Department of Pharmaceutics and Industrial Pharmacy, Faculty of Pharmacy, Ain Shams University, Monazzamet Elwehda Elafrikeya Street, Abbaseyya, Cairo 11566, Egypt
| | - Mahmoud E Soliman
- Department of Pharmaceutics and Industrial Pharmacy, Faculty of Pharmacy, Ain Shams University, Monazzamet Elwehda Elafrikeya Street, Abbaseyya, Cairo 11566, Egypt
| | - Athanasios Skouras
- Department of Life Sciences, School of Sciences, European University Cyprus, 1516 Nicosia, Cyprus
| | - Luca Casettari
- Department of Biomolecular Sciences, School of Pharmacy, University of Urbino, Piazza Rinascimento, 6, 61029 Urbino, Pesaro and Urbino, Italy
| | - Ahmed S Geneidi
- Department of Pharmaceutics and Industrial Pharmacy, Faculty of Pharmacy, Ain Shams University, Monazzamet Elwehda Elafrikeya Street, Abbaseyya, Cairo 11566, Egypt
| | - Rania A H Ishak
- Department of Pharmaceutics and Industrial Pharmacy, Faculty of Pharmacy, Ain Shams University, Monazzamet Elwehda Elafrikeya Street, Abbaseyya, Cairo 11566, Egypt
| |
Collapse
|
7
|
Abdeltawab H, Svirskis D, Sharma M. Formulation strategies to modulate drug release from poloxamer based in situ gelling systems. Expert Opin Drug Deliv 2020; 17:495-509. [PMID: 32067500 DOI: 10.1080/17425247.2020.1731469] [Citation(s) in RCA: 58] [Impact Index Per Article: 11.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/20/2022]
Abstract
Introduction: Poloxamer based in situ gelling systems offer numerous advantages in drug delivery; however, their application as prolonged-release delivery platforms is limited mainly due to their weak mechanical properties and the interconnected aqueous network causing fast gel erosion and drug diffusion.Area covered: The focus of this review is to provide an insightful discussion on the formulation strategies that can be employed to sustain/prolong the drug release from poloxamer based in situ gelling systems. The review also outlines the formulation factors, influencing drug release from these systems.Expert opinion: The nature, composition, and concentration of poloxamers are the most critical factors in defining the rate of drug release from an in situ gelling matrix. Hydrophobic gel matrices have compact micellar arrangements resulting in slow diffusion and erosion. Depending on the intended clinical application, gel characteristics can be modulated, either by physical blending or by chemical crosslinking with additive materials, to slow release and improve residence time at the administration site. Incorporating drug-loaded particles into poloxamer gels sustains drug release by creating multiple rate-limiting release barriers. Chemical modification of poloxamers appears to be a promising strategy to obtain prolonged sustained release for parenteral application without compromising the rheological properties of the formulation.
Collapse
Affiliation(s)
- Hani Abdeltawab
- School of Pharmacy, Faculty of Medical & Health Sciences, The University of Auckland, Auckland, New Zealand
| | - Darren Svirskis
- School of Pharmacy, Faculty of Medical & Health Sciences, The University of Auckland, Auckland, New Zealand
| | - Manisha Sharma
- School of Pharmacy, Faculty of Medical & Health Sciences, The University of Auckland, Auckland, New Zealand
| |
Collapse
|
8
|
Mertz N, Østergaard J, Yaghmur A, Larsen SW. Transport characteristics in a novel in vitro release model for testing the performance of intra-articular injectables. Int J Pharm 2019; 566:445-453. [DOI: 10.1016/j.ijpharm.2019.04.083] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/20/2019] [Revised: 04/12/2019] [Accepted: 04/13/2019] [Indexed: 12/25/2022]
|
9
|
Simulated synovial fluids for in vitro drug and prodrug release testing of depot injectables intended for joint injection. J Drug Deliv Sci Technol 2019. [DOI: 10.1016/j.jddst.2018.11.012] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/31/2022]
|
10
|
Ning C, Guo Y, Yan L, Thawani JP, Zhang W, Fu C, Liu T, Ding J. On-Demand Prolongation of Peripheral Nerve Blockade through Bupivacaine-Loaded Hydrogels with Suitable Residence Periods. ACS Biomater Sci Eng 2018; 5:696-709. [PMID: 33405832 DOI: 10.1021/acsbiomaterials.8b01107] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
Affiliation(s)
- Cong Ning
- Key Laboratory of Polymer Ecomaterials, Changchun Institute of Applied Chemistry, Chinese Academy of Sciences, 5625 Renmin Street, Changchun 130022, People’s Republic of China
- Department of Spine Surgery, The First Hospital of Jilin University, 71 Xinmin Street, Changchun 130021, People’s Republic of China
| | - Ying Guo
- Key Laboratory of Polymer Ecomaterials, Changchun Institute of Applied Chemistry, Chinese Academy of Sciences, 5625 Renmin Street, Changchun 130022, People’s Republic of China
- Department of Anesthesia, The Second Hospital of Jilin University, 218 Ziqiang Street, Changchun 130041, People’s Republic of China
| | - Lesan Yan
- Department of Bioengineering, University of Pennsylvania, 210 South 33rd Street, Philadelphia, Pennsylvania 19104, United States
| | - Jayesh P. Thawani
- Department of Bioengineering, University of Pennsylvania, 210 South 33rd Street, Philadelphia, Pennsylvania 19104, United States
- Department of Neurosurgery, Hospital of the University of Pennsylvania, 3400 Spruce Street, Philadelphia, Pennsylvania 19104, United States
| | - Wenjing Zhang
- Key Laboratory of Polymer Ecomaterials, Changchun Institute of Applied Chemistry, Chinese Academy of Sciences, 5625 Renmin Street, Changchun 130022, People’s Republic of China
- Department of Anesthesia, China-Japan Union Hospital of Jilin University, 126 Xiantai Street, Changchun 130033, People’s Republic of China
| | - Changfeng Fu
- Department of Spine Surgery, The First Hospital of Jilin University, 71 Xinmin Street, Changchun 130021, People’s Republic of China
| | - Tiecheng Liu
- Department of Anesthesia, The Second Hospital of Jilin University, 218 Ziqiang Street, Changchun 130041, People’s Republic of China
| | - Jianxun Ding
- Key Laboratory of Polymer Ecomaterials, Changchun Institute of Applied Chemistry, Chinese Academy of Sciences, 5625 Renmin Street, Changchun 130022, People’s Republic of China
| |
Collapse
|
11
|
Analysis of the Postoperative Periarticular Environment and Influence on Sustained Drug Delivery From a Gel Formulation. J Pharm Sci 2018; 107:2399-2403. [DOI: 10.1016/j.xphs.2018.05.004] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/08/2018] [Revised: 05/07/2018] [Accepted: 05/09/2018] [Indexed: 11/16/2022]
|