She Y, Jiang Z, Liu Q, Qiao S, Ma Y. Enhancing the precision of impedance measurement from 5 kHz to 1 MHz through self-identification of parasitic parameters. Physiol Meas 2025; 46:035004. [PMID: 39993376 DOI: 10.1088/1361-6579/adb9b4] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/31/2024] [Accepted: 02/24/2025] [Indexed: 02/26/2025]
Abstract
Objective.Electrical impedance tomography (EIT) generates cross-sectional images through non-invasive impedance measurements from surface electrodes. While impedance above 200 kHz can reveal intracellular properties, most existing EIT images are published at frequencies below 200 kHz. When frequencies exceed 200 kHz, the accuracy of impedance measurements declines due to the distributed circuit parameters such as parasitic capacitance, on-resistance of switch and the series inductance, with a more significant impact on larger impedance. To overcome this limitation, this paper proposes an approach to enhance the precision of impedance measurement through self-identification of distributed parameter.Approach.Firstly, the distributed circuit parameters are identified via correction measurements of precision resistances in the frequency range from 5 kHz to 1 MHz; then, the circuit is accurately modeled; finally, transfer impedance measurements during imaging process are corrected using the established circuit model.Main results.The distributed circuit parameter self-identification method was verified through a goodness-of-fit test, confirming the consistency between the model's predicted values and the actual values of the component. The test results indicate that at 1 MHz, the relative residuals follow a right-skewed distribution with an average value of 0.08%, which demonstrates high model accuracy. At 1 MHz, the relative error after correction for the 499 Ω precision resistor measurement is reduced by 12.01%, and for the 56 pF precision capacitor in parallel with 249 Ω, the relative error after correction is 0.46%.Significance.The proposed method can extend the frequency range of EIT and other impedance technologies from below 200 kHz to up to 1 MHz, while ensuring good measurement accuracy.
Collapse
Affiliation(s)
- Yi She
- School of Electronic Information and Electrical Engineering, Shanghai Jiaotong University, Shanghai 200240, People's Republic of China
| | - Zeyi Jiang
- School of Electronic Information and Electrical Engineering, Shanghai Jiaotong University, Shanghai 200240, People's Republic of China
| | - Qin Liu
- School of Electronic Information and Electrical Engineering, Shanghai Jiaotong University, Shanghai 200240, People's Republic of China
| | - Sirui Qiao
- School of Electronic Information and Electrical Engineering, Shanghai Jiaotong University, Shanghai 200240, People's Republic of China
| | - Yixin Ma
- School of Electronic Information and Electrical Engineering, Shanghai Jiaotong University, Shanghai 200240, People's Republic of China
| |
Collapse
|
2
|
Escobar Fernández J, Martínez López C, Mosquera Leyton V. A low-cost, portable 32-channel EIT system with four rings based on AFE4300 for body composition analysis. HARDWAREX 2023; 16:e00494. [PMID: 38186666 PMCID: PMC10767629 DOI: 10.1016/j.ohx.2023.e00494] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 07/18/2023] [Revised: 09/19/2023] [Accepted: 11/11/2023] [Indexed: 01/09/2024]
Abstract
A proposed low-cost, portable, 32-channel (4 rings of 8-channel) Electrical Impedance Tomography (EIT) system based on the AFE4300 analog front-end for body composition measurement. Each ring allows obtaining the conductivity distribution of 4 cross sections, 4 cm apart; to analyze the behavior of conductivity in a volume. The switching of the 4 rings and the current injection and voltage measurement patterns are done with three Texas Instruments 74HC4067 multiplexers, which are managed by an ESP32 board. The proposed system has an average signal-to-noise ratio of 74.71 dB and a frame rate of 50 fps. The sensitivity tests to impedance and volume changes consisted of introducing 4 tubes of different diameters (2 steel and 2 polyvinyl chloride) into a tank with saline solution; then conductivity distribution images were generated in 4 cross-sections of the tank, using the algorithms Gauss-Newton and Noser. Finally, the global impedance index (GI) is calculated to estimate the volume of each tube inside the tank. The results show that the proposed system is highly sensitive to impedance and volume changes, being a promising system for monitoring tissues, and fluids biological.
Collapse
Affiliation(s)
| | | | - Víctor Mosquera Leyton
- Universidad del Cauca, Electronic, Instrumentation, and Control Department, Street 5 No 4-70, Popayán, Colombia
| |
Collapse
|
3
|
Poshti AGT, Ansari MA, Ayani MB. The Developed Conservation Element and Solution Element Method in Two-Dimensional Spherical Coordinate and Its Application to the Analysis of Non-Fourier Heat Conduction. ARABIAN JOURNAL FOR SCIENCE AND ENGINEERING 2023. [DOI: 10.1007/s13369-023-07797-7] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 03/31/2023]
|
4
|
Affordable, portable and self-administrable electrical impedance tomography enables global and regional lung function assessment. Sci Rep 2022; 12:20613. [PMID: 36450830 PMCID: PMC9712422 DOI: 10.1038/s41598-022-24330-2] [Citation(s) in RCA: 11] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/13/2022] [Accepted: 11/14/2022] [Indexed: 12/12/2022] Open
Abstract
Accessibility of diagnostic screening and treatment monitoring devices for respiratory diseases is critical in promoting healthcare and reducing sudden complications and mortality. Spirometry is the standard for diagnosing and monitoring several lung diseases. However, it lacks regional assessment capabilities necessary for detecting subtle regional changes in certain diseases. It also requires challenging breathing maneuvers difficult for elderlies, children, and diseased patients. Here, we actualized an affordable, portable, and self-administrable electrical impedance tomography (EIT) system for home-based lung function assessment and telemedicine. Through simultaneous EIT-spirometry trials on healthy subjects, we demonstrated that our device can predict spirometry indicators over a wide range and can provide regional mapping of these indicators. We further developed a close-to-effortless breathing paradigm and tested it by longitudinally monitoring a COVID-19 discharged subject and two healthy controls with results suggesting the paradigm can detect initial deterioration followed by recovery. Overall, the EIT system can be widely applicable for lung function screening and monitoring both at homes and clinics.
Collapse
|
5
|
A Rapid, Low-Cost, and High-Precision Multifrequency Electrical Impedance Tomography Data Acquisition System for Plant Phenotyping. REMOTE SENSING 2022. [DOI: 10.3390/rs14133214] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
Plant phenotyping plays an important role for the thorough assessment of plant traits such as growth, development, and physiological processes with the target of achieving higher crop yields by the proper crop management. The assessment can be done by utilizing two- and three-dimensional image reconstructions of the inhomogeneities. The quality of the reconstructed image is required to maintain a high accuracy and a good resolution, and it is desirable to reconstruct the images with the lowest possible noise. In this work, an electrical impedance tomography (EIT) data acquisition system is developed for the reconstruction and evaluation of the inhomogeneities by utilizing a non-destructive method. A high-precision EIT system is developed by designing an electrode array sensor using a cylindrical domain for the measurements in different planes. Different edible plant slices along with multiple plant roots are taken in the EIT domain to assess and calibrate the system, and their reconstructed results are evaluated by utilizing an impedance imaging technique. A non-invasive imaging is carried out in multiple frequencies by utilizing a difference method of reconstruction. The performance and accuracy of the EIT system are evaluated by measuring impedances between 1 and 100 kHz using a low-cost and rapid electrical impedance spectroscopy (EIS) tool connected to the sensor. A finite element method (FEM) modeling is utilized for image reconstruction, which is carried out using electrical impedance and diffuse optical tomography reconstruction software (EIDORS). The reconstruction is made successfully with the optimized results obtained using Gauss–Newton (GN) algorithms.
Collapse
|
6
|
An In Situ Electrical Impedance Tomography Sensor System for Biomass Estimation of Tap Roots. PLANTS 2022; 11:plants11131713. [PMID: 35807666 PMCID: PMC9269135 DOI: 10.3390/plants11131713] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 06/16/2022] [Revised: 06/24/2022] [Accepted: 06/26/2022] [Indexed: 12/02/2022]
Abstract
Root biomass is one of the most relevant root parameters for studies of plant response to environmental change. In this work, a dynamic and adjustable electrode array sensor system is designed for developing a cost-effective, high-speed data acquisition system based on electrical impedance tomography (EIT). The developed EIT system is found to be suitable for in situ measurements and capable of monitoring the changes in root growth and development with three-dimensional imaging by measuring impedances in multiple frequencies with the help of an EIT sensor. The designed EIT sensor system is assessed and calibrated by the inhomogeneities in both water and soil media. The impedances are measured for multiple tap roots using an electrical impedance spectroscopy (EIS) tool connected to the sensor at frequencies ranging from 1 kHz to 100 kHz. The changes in conductivity are calculated by obtaining the boundary voltages from the measured impedances for a given stimulation current. A non-invasive imaging method is utilized, and the spectral changes are observed accordingly to evaluate the growth of the roots. A further root analysis helps us estimate the root biomass non-destructively in real-time. The root size (such as, weight, length) is correlated with the measured impedances. A regression analysis is performed using the least square method, and more than 97% correlation is found for the biomass estimation of carrot roots with an RMSE of 4.516. The obtained models are later validated using a new and separate set of carrot root samples and the accuracy of the predicted models is found to be 93% or above. A complete electrode model is utilized, and the reconstruction analysis is performed and optimized by utilizing the impedance imaging technique in difference method. The tomography of the root is reconstructed with finite element method (FEM) modeling considering one-step Gauss–Newton (GN) algorithm which is carried out using an open source software known as electrical impedance and diffuse optical tomography reconstruction software (EIDORS).
Collapse
|
7
|
Muñoz JD, Mosquera VH, Rengifo CF. A low-cost, portable, two-dimensional bioimpedance distribution estimation system based on the AD5933 impedance converter. HARDWAREX 2022; 11:e00274. [PMID: 35509922 PMCID: PMC9058721 DOI: 10.1016/j.ohx.2022.e00274] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 09/02/2021] [Revised: 01/25/2022] [Accepted: 02/02/2022] [Indexed: 06/14/2023]
Abstract
This study proposes a low-cost, portable, eight-channel electrical impedance tomograph based on the AD5933 impedance converter. The patterns for current injection and voltage measurement are managed by an Arduino Mega 2560 board and four 74HC4067 Texas Instruments multiplexers. Regarding the experimental results, the errors in the impedance estimates of an electrical circuit that represents a Cole model were less than 1.14% for the magnitude and 4.15% for the phase. Furthermore, the signal-to-noise ratio measured in a resistive phantom was 55.23 dB. Additional experiments consisted of placing five spheres of different size and conductivity in a saline tank, measuring their impedance through eight electrodes, and then generating impedance maps using the Electrical Impedance Tomography and Diffuse Optical Tomography Reconstruction Software (EIDORS). These maps were different for each sphere, suggesting the proposed prototype as a promising alternative for medical applications.
Collapse
Affiliation(s)
- Juan D. Muñoz
- Research Group of Automation, Universidad del Cauca, Colombia
| | - Víctor H. Mosquera
- Department of Electronic Instrumentation and Control, Universidad del Cauca, Colombia
| | - Carlos F. Rengifo
- Department of Electronic Instrumentation and Control, Universidad del Cauca, Colombia
| |
Collapse
|
8
|
Gómez-Cortés JC, Díaz-Carmona JJ, Padilla-Medina JA, Calderon AE, Gutiérrez AIB, Gutiérrez-López M, Prado-Olivarez J. Electrical Impedance Tomography Technical Contributions for Detection and 3D Geometric Localization of Breast Tumors: A Systematic Review. MICROMACHINES 2022; 13:mi13040496. [PMID: 35457801 PMCID: PMC9025021 DOI: 10.3390/mi13040496] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 02/28/2022] [Revised: 03/18/2022] [Accepted: 03/21/2022] [Indexed: 12/30/2022]
Abstract
Impedance measuring acquisition systems focused on breast tumor detection, as well as image processing techniques for 3D imaging, are reviewed in this paper in order to define potential opportunity areas for future research. The description of reported works using electrical impedance tomography (EIT)-based techniques and methodologies for 3D bioimpedance imaging of breast tissues with tumors is presented. The review is based on searching and analyzing related works reported in the most important research databases and is structured according to the Preferred Reporting Items for Systematic Reviews and Meta-analysis (PRISMA) parameters and statements. Nineteen papers reporting breast tumor detection and location using EIT were systematically selected and analyzed in this review. Clinical trials in the experimental stage did not produce results in most of analyzed proposals (about 80%), wherein statistical criteria comparison was not possible, such as specificity, sensitivity and predictive values. A 3D representation of bioimpedance is a potential tool for medical applications in malignant breast tumors detection being capable to estimate an ap-proximate the tumor volume and geometric location, in contrast with a tumor area computing capacity, but not the tumor extension depth, in a 2D representation.
Collapse
|
9
|
Liu JZ, Li XB, Xiong H. A FPGA-based adaptive differential current source for electrical impedance tomography. THE REVIEW OF SCIENTIFIC INSTRUMENTS 2021; 92:094707. [PMID: 34598505 DOI: 10.1063/5.0062640] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/07/2021] [Accepted: 08/23/2021] [Indexed: 06/13/2023]
Abstract
A high output impedance current source with a wide bandwidth is needed in electrical impedance tomography systems. Limitations appear mainly at higher frequencies and non-simple loads. In order to adjust the output current, the amplitude and phase are made to achieve the expected value automatically. A current source based on the field programmable gate array is designed. In this paper, we proposed a double DAC differential current source structure. By measuring the voltage of the sampling resistor in series with the load and using the proposed dynamic reference point demodulation algorithm, the actual current amplitude and phase on the load can be quickly obtained. Through the adaptive compensation module, the output current is adjusted to the expected value. The experimental results show that the output resistance of the current source can reach 10 MΩ and the output capacitance can be less than 0.8 pF in the frequency range of 10 kHz-1.28 MHz. At the same time, the current amplitude attenuation is less than 0.016%, and the phase error is less than 0.0025° after compensation. Therefore, the proposed current source achieves widebands, biocompatibility, and high precision.
Collapse
Affiliation(s)
- J Z Liu
- The School of Control Science and Engineering, Tiangong University, Tianjin 300387, People's Republic of China
| | - X B Li
- The School of Control Science and Engineering, Tiangong University, Tianjin 300387, People's Republic of China
| | - H Xiong
- The School of Control Science and Engineering, Tiangong University, Tianjin 300387, People's Republic of China
| |
Collapse
|