1
|
Chen B, Qian Z, Song G, Niu X, Yu Y, Wang S, Wu J, Ma S, Liang Y, Ren L, Ren L. Bioinspired Flexible Epidermal Electronics with Superior Gas Permeability and Unidirectional Water Transport Capability. NANO LETTERS 2025. [PMID: 40012259 DOI: 10.1021/acs.nanolett.4c05791] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 02/28/2025]
Abstract
Epidermal electronics are extensively used in human-machine interfaces and wearable sensors. However, managing sweat and gas permeability at the skin-device interface to ensure comfort and prevent skin damage during prolonged use remains a key challenge. Inspired by the fog collection mechanism of cactus spines and trichomes, this work develops a biomimetic, flexible epidermal electronic device with high gas permeability and unidirectional water transport capability. The device exhibits excellent flexibility (Young's modulus: 0.02 MPa), breathability (electrode: 3551.63 g day-1 m-2, substrate: 3795.38 g day-1 m-2), unidirectional water transport (1.09 s), and antigravity water transport (2.50 s). Notably, during continuous sweating (5 h) and extended wear (7 days), it demonstrates outstanding electromyography (EMG) signal acquisition, with a signal-to-noise ratio (SNR) approximately 58 times higher than that of commercial electrodes. This offers promising potential for advancing high-performance, wearable human-machine interface electronics.
Collapse
Affiliation(s)
- Boya Chen
- Key Laboratory of Bionic Engineering, Ministry of Education, Jilin University, Changchun 130022, China
| | - Zhihui Qian
- Key Laboratory of Bionic Engineering, Ministry of Education, Jilin University, Changchun 130022, China
- Institute of Structured and Architected Materials, Liaoning Academy of Materials, Shenyang 110167, China
| | - Guangsheng Song
- Key Laboratory of Bionic Engineering, Ministry of Education, Jilin University, Changchun 130022, China
| | - Xiaoru Niu
- Key Laboratory of Bionic Engineering, Ministry of Education, Jilin University, Changchun 130022, China
| | - Yingqing Yu
- Key Laboratory of Bionic Engineering, Ministry of Education, Jilin University, Changchun 130022, China
| | - Shengli Wang
- Key Laboratory of Bionic Engineering, Ministry of Education, Jilin University, Changchun 130022, China
| | - Jianan Wu
- Key Laboratory of Bionic Engineering, Ministry of Education, Jilin University, Changchun 130022, China
| | - Suqian Ma
- Key Laboratory of Bionic Engineering, Ministry of Education, Jilin University, Changchun 130022, China
- Institute of Structured and Architected Materials, Liaoning Academy of Materials, Shenyang 110167, China
| | - Yunhong Liang
- Key Laboratory of Bionic Engineering, Ministry of Education, Jilin University, Changchun 130022, China
- Institute of Structured and Architected Materials, Liaoning Academy of Materials, Shenyang 110167, China
| | - Lei Ren
- Key Laboratory of Bionic Engineering, Ministry of Education, Jilin University, Changchun 130022, China
- Institute of Structured and Architected Materials, Liaoning Academy of Materials, Shenyang 110167, China
- Department of Mechanical, Aerospace and Civil Engineering, University of Manchester, Manchester M13 9PL, United Kingdom
| | - Luquan Ren
- Key Laboratory of Bionic Engineering, Ministry of Education, Jilin University, Changchun 130022, China
- Institute of Structured and Architected Materials, Liaoning Academy of Materials, Shenyang 110167, China
| |
Collapse
|
2
|
Tsogbayar D, Seo J, Hwang T, Park J, Ko E, Kim Y, Yoon CM, Lee HS. Advanced Flexible Physical Sensors with Independent Detection Mechanisms of Pressure and Strain Stimuli for Overcoming Signal Interference. ACS APPLIED MATERIALS & INTERFACES 2024; 16:49574-49583. [PMID: 39254113 DOI: 10.1021/acsami.4c09337] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 09/11/2024]
Abstract
Flexible and wearable physical sensors have gained significant interest owing to their potential in attachable devices, electronic skin, and multipurpose sensors. The physical stimuli of these sensors typically consist of vertically and horizontally applied pressures and strains, respectively. However, owing to their similar response characteristics, interference occurs between the two types of signals detected, complicating the distinction between pressure and strain stimuli, leading to inaccurate data interpretation and reduced sensor specificity. Therefore, we developed a dual-sensing-mode physical sensor with separate response mechanisms for the two types of physical stimuli based on a unique structural design that can independently induce changes in the piezocapacitance and piezoresistance for pressure and strain stimuli, respectively. The asterisk-shaped piezoresistive pathway (electrode), designed for multifunctionality, effectively detected the intensity and direction of tensile deformation, and an elastomeric sponge structure positioned between the two electrodes detected the pressure signals via changes in capacitance. This dual-sensing-mode sensor offers clearer signal differentiation and enhanced multifunctionality compared to those of traditional single-mode sensors. Additionally, extensive experimentation demonstrated that our sensor has a good sensitivity, high linearity, and stability in detecting signals, proving its applicability for sophisticated monitoring and control tasks that require the differential detection between pressure and deformation signals.
Collapse
Affiliation(s)
- Dashdendev Tsogbayar
- Department of Materials Science and Chemical Engineering, Hanyang University, Ansan 15588, Republic of Korea
- BK21 FOUR ERICA-ACE Center, Hanyang University, Ansan 15588, Republic of Korea
| | - Jungyoon Seo
- Department of Materials Science and Chemical Engineering, Hanyang University, Ansan 15588, Republic of Korea
- BK21 FOUR ERICA-ACE Center, Hanyang University, Ansan 15588, Republic of Korea
| | - Taehoon Hwang
- Department of Materials Science and Chemical Engineering, Hanyang University, Ansan 15588, Republic of Korea
- BK21 FOUR ERICA-ACE Center, Hanyang University, Ansan 15588, Republic of Korea
| | - Jisu Park
- Department of Materials Science and Chemical Engineering, Hanyang University, Ansan 15588, Republic of Korea
- BK21 FOUR ERICA-ACE Center, Hanyang University, Ansan 15588, Republic of Korea
| | - Eun Ko
- Department of Materials Science and Chemical Engineering, Hanyang University, Ansan 15588, Republic of Korea
- BK21 FOUR ERICA-ACE Center, Hanyang University, Ansan 15588, Republic of Korea
| | - Yumin Kim
- Department of Materials Science and Chemical Engineering, Hanyang University, Ansan 15588, Republic of Korea
- BK21 FOUR ERICA-ACE Center, Hanyang University, Ansan 15588, Republic of Korea
| | - Chang-Min Yoon
- Department of Chemical and Biological Engineering, Hanbat National University, Daejeon 34158, Republic of Korea
| | - Hwa Sung Lee
- Department of Materials Science and Chemical Engineering, Hanyang University, Ansan 15588, Republic of Korea
- BK21 FOUR ERICA-ACE Center, Hanyang University, Ansan 15588, Republic of Korea
| |
Collapse
|
3
|
Farhoudi M, Hajiaghaei B, Saeedi H, Babaee T. A New Socket Prototype Design with a Heat-Exchanging Metal Layer for Individuals with Below-knee Amputation. Med J Islam Repub Iran 2024; 38:94. [PMID: 39678776 PMCID: PMC11644191 DOI: 10.47176/mjiri.38.94] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/18/2024] [Indexed: 12/17/2024] Open
Abstract
Background Individuals who have undergone lower limb amputation often struggle with excessive heat and sweating in their prosthetic sockets. This is due to the closed environment of the socket, which disrupts the body's natural cooling mechanisms and can lead to increased skin temperature, sweating, and various skin problems. This study aimed to develop a new socket to alleviate heat buildup in those with below-knee amputation. Methods A positive residual limb model of a below-knee amputee was used to create a new socket made of copper metal through electroforming. A cooling system was programmed so that if the temperature exceeded a predetermined threshold, the system would be activated to prevent further temperature increase. The participant wore the conventional and new socket with the cooling system, and his residual limb skin temperature was monitored using a temperature data logger. Results Implementing the new socket led to a significant 5°C to 6°C reduction in temperature within the socket, greatly enhancing thermal comfort and reducing heat sensation for the users. Conclusion By incorporating the new socket and cooling system, substantial reductions in heat accumulation within the prosthetic socket can be achieved.
Collapse
Affiliation(s)
- Mahboobeh Farhoudi
- Department of Orthotics and Prosthetics, School of Rehabilitation Sciences, Iran University of Medical Sciences, Tehran, Iran
| | - Behnam Hajiaghaei
- Department of Orthotics and Prosthetics, School of Rehabilitation Sciences, Iran University of Medical Sciences, Tehran, Iran
| | - Hassan Saeedi
- Department of Orthotics and Prosthetics, School of Rehabilitation Sciences, Iran University of Medical Sciences, Tehran, Iran
| | - Taher Babaee
- Department of Orthotics and Prosthetics, School of Rehabilitation Sciences, Iran University of Medical Sciences, Tehran, Iran
| |
Collapse
|
4
|
Ghiami Rad A, Shahbazi B. A systematic investigation of sensorimotor mechanisms with intelligent prostheses in patients with ankle amputation while walking. J Mech Behav Biomed Mater 2024; 151:106357. [PMID: 38181570 DOI: 10.1016/j.jmbbm.2023.106357] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/21/2023] [Accepted: 12/25/2023] [Indexed: 01/07/2024]
Abstract
It is thought that creating sensorimotor feedback in people with ankle joint amputation can affect motor biomechanics during gait, but there is little evidence or previous research. This study e aim ed to investigate the sensorimotor mechanism of smart prostheses in with ankle amputations while walking. Search in Google Scholar, Scopus, PubMed and Medline databases between April 2017 and February 2023, in addition to a detailed review in specialized clinical and engineering databases, 29 articles were selected based on the inclusion and exclusion criteria. Trials that mainly include; Proprioception, walking process in movement disorders, ankle amputation were included. Qualitative assessments of selected trials using PEDro' scale was used. The review of studies showed that the use of pressure sensors, neural stimulation through encoded algorithms can provide continuous tactile and positional information of the artificial leg in the direction of neural stimulation throughout the entire walking cycle. These findings indicate that restoration of intraneuronal sensory feedback leads to functional and cognitive benefits. With these definitions, different companies and research centers are trying to improve the mechanics of walking, however, movement strategies are unknown despite little research in creating sense and movement in the use of smart prostheses.
Collapse
Affiliation(s)
- Amir Ghiami Rad
- Movement Biomechanics, Department of Movement Behavior, Faculty of Sports Sciences, University Of Tabriz, Tabriz, Iran.
| | - Behnam Shahbazi
- Movement Biomechanics, Department of Sports Biomechanics, Faculty of Sports Sciences, Bu- Ali Sina University, Hamadan, Iran.
| |
Collapse
|
5
|
Phillips C, Li L, Miguel M, Eshraghi A, Heim W, Dilkas S, Devlin M, Wasilewski M, Verweel L, MacKay C. User perspectives of digital manufacturing for lower-limb prosthetic sockets. Prosthet Orthot Int 2024; 48:100-107. [PMID: 37639567 DOI: 10.1097/pxr.0000000000000259] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/31/2022] [Accepted: 06/09/2023] [Indexed: 08/31/2023]
Abstract
BACKGROUND There is growing interest to use digital technology (DT) for manufacturing lower-limb prosthetic sockets to improve efficiency and clinical outcomes. However, little is known about how lower-limb prosthesis users perceive DTs, such as 3D scanning and 3D printing. OBJECTIVES This study aimed to provide an understanding of perceptions and experiences with DT for prosthetic socket manufacturing from the perspective of prosthesis users. STUDY DESIGN A qualitative descriptive research study. METHODS Nine lower-limb prosthesis users (mean age 56; 5 female; 4 male) participated in one-on-one semistructured telephone interviews. Inductive thematic analysis was performed to identify a codebook and emerging themes from the interview transcripts. RESULTS Two major themes were identified: (1) expectations and prioritization of 3D printed socket usability and (2) facilitators and barriers to uptake of DT among patients. CONCLUSION DT methods were found to be acceptable and feasible from a patient perspective, although technological advancements are still required, and real-time communication about the process may be vital for ensuring patient engagement. Consideration of these findings may improve patient satisfaction to emerging prosthesis treatment plans and ultimately support widespread adoption of DT as an additional tool for fabricating prosthetic sockets.
Collapse
Affiliation(s)
| | - Lynn Li
- Department of Occupational Science and Occupational Therapy, University of Toronto, Toronto, Canada
| | - Marian Miguel
- Department of Occupational Science and Occupational Therapy, University of Toronto, Toronto, Canada
| | | | | | - Steven Dilkas
- West Park Healthcare Centre, Toronto, Canada
- Division of Physical Medicine and Rehabilitation, Temerty Faculty of Medicine, University of Toronto, Toronto, Canada
| | | | - Marina Wasilewski
- Department of Occupational Science and Occupational Therapy, University of Toronto, Toronto, Canada
- St John's Rehab, Sunnybrook Health Sciences Centre, Toronto, Canada
- Rehabilitation Sciences Institute, University of Toronto, Toronto, Canada
| | - Lee Verweel
- West Park Healthcare Centre, Toronto, Canada
| | - Crystal MacKay
- West Park Healthcare Centre, Toronto, Canada
- Rehabilitation Sciences Institute, University of Toronto, Toronto, Canada
- Department of Physical Therapy, University of Toronto, Toronto, Canada
| |
Collapse
|
6
|
A hierarchical classification of gestures under two force levels based on muscle synergy. Biomed Signal Process Control 2022. [DOI: 10.1016/j.bspc.2022.103695] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
|
7
|
Zhu W, Chen Y, Ko ST, Lu Z. Redundancy Reduction for Sensor Deployment in Prosthetic Socket: A Case Study. SENSORS (BASEL, SWITZERLAND) 2022; 22:3103. [PMID: 35590792 PMCID: PMC9105868 DOI: 10.3390/s22093103] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 03/02/2022] [Revised: 04/12/2022] [Accepted: 04/16/2022] [Indexed: 06/15/2023]
Abstract
The irregular pressure exerted by a prosthetic socket over the residual limb is one of the major factors that cause the discomfort of amputees using artificial limbs. By deploying the wearable sensors inside the socket, the interfacial pressure distribution can be studied to find the active regions and rectify the socket design. In this case study, a clustering-based analysis method is presented to evaluate the density and layout of these sensors, which aims to reduce the local redundancy of the sensor deployment. In particular, a Self-Organizing Map (SOM) and K-means algorithm are employed to find the clustering results of the sensor data, taking the pressure measurement of a predefined sensor placement as the input. Then, one suitable clustering result is selected to detect the layout redundancy from the input area. After that, the Pearson correlation coefficient (PCC) is used as a similarity metric to guide the removal of redundant sensors and generate a new sparser layout. The Jenson-Shannon Divergence (JSD) and the mean pressure are applied as posterior validation metrics that compare the pressure features before and after sensor removal. A case study of a clinical trial with two sensor strips is used to prove the utility of the clustering-based analysis method. The sensors on the posterior and medial regions are suggested to be reduced, and the main pressure features are kept. The proposed method can help sensor designers optimize sensor configurations for intra-socket measurements and thus assist the prosthetists in improving the socket fitting.
Collapse
Affiliation(s)
- Wenyao Zhu
- School of Electrical Engineering and Computer Science, KTH Royal Institute of Technology, 10044 Stockholm, Sweden; (W.Z.); (Y.C.)
| | - Yizhi Chen
- School of Electrical Engineering and Computer Science, KTH Royal Institute of Technology, 10044 Stockholm, Sweden; (W.Z.); (Y.C.)
| | - Siu-Teing Ko
- Research and Innovation, Össur, 110 Reykjavík, Iceland;
| | - Zhonghai Lu
- School of Electrical Engineering and Computer Science, KTH Royal Institute of Technology, 10044 Stockholm, Sweden; (W.Z.); (Y.C.)
| |
Collapse
|
8
|
Raschke SU. Limb Prostheses: Industry 1.0 to 4.0: Perspectives on Technological Advances in Prosthetic Care. FRONTIERS IN REHABILITATION SCIENCES 2022; 3:854404. [PMID: 36188935 PMCID: PMC9397934 DOI: 10.3389/fresc.2022.854404] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 01/13/2022] [Accepted: 02/10/2022] [Indexed: 11/13/2022]
Abstract
Technological advances from Industry 1.0 to 4.0, have exercised an increasing influence on prosthetic technology and practices. This paper explores the historical development of the sector within the greater context of industrial revolution. Over the course of the first and up the midpoint of the second industrial revolutions, Industry 1.0 and 2.0, the production and provision of prosthetic devices was an ad hoc process performed by a range of craftspeople. Historical events and technological innovation in the mid-part of Industry 2.0 created an inflection point resulting in the emergence of prosthetists who concentrated solely on hand crafting and fitting artificial limbs as a professional specialty. The third industrial revolution, Industry 3.0, began transforming prosthetic devices themselves. Static or body powered devices began to incorporate digital technology and myoelectric control options and hand carved wood sockets transitioned to laminated designs. Industry 4.0 continued digital advancements and augmenting them with data bases which to which machine learning (M/L) could be applied. This made it possible to use modeling software to better design various elements of prosthetic componentry in conjunction with new materials, additive manufacturing processes and mass customization capabilities. Digitization also began supporting clinical practices, allowing the development of clinical evaluation tools which were becoming a necessity as those paying for devices began requiring objective evidence that the prosthetic technology being paid for was clinically and functionally appropriate and cost effective. Two additional disruptive dynamics emerged. The first was the use of social media tools, allowing amputees to connect directly with engineers and tech developers and become participants in the prosthetic design process. The second was innovation in medical treatments, from diabetes treatments having the potential to reduce the number of lower limb amputations to Osseointegration techniques, which allow for the direct attachment of a prosthesis to a bone anchored implant. Both have the potential to impact prosthetic clinical and business models. Questions remains as to how current prosthetic clinical practitioners will respond and adapt as Industry 4.0 as it continues to shape the sector.
Collapse
Affiliation(s)
- Silvia Ursula Raschke
- British Columbia Institute of Technology, Applied Research, MAKE+, Burnaby, BC, Canada
| |
Collapse
|
9
|
Jones D, Vardakastani V, Kedgley AE, Gardiner MD, Vincent TL, Culmer PR, Alazmani A. HAILO: A Sensorised Hand Splint for the Exploration of Interaction Forces. IEEE Trans Biomed Eng 2022; 69:2850-2859. [PMID: 35230945 DOI: 10.1109/tbme.2022.3155589] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/10/2022]
Abstract
This study presents the design and development of an instrumented splint for measuring the biomechanical effects of hand splinting, and for assessing interface loading characteristics for people with arthritis. Sixteen multi-axial soft load-sensing nodes were mounted on the splint-skin interface of a custom 3D printed thumb splint. The splint was used to measure the interface forces between splint and hand in 12 healthy participants in 6 everyday tasks. Forces were compared between a baseline relaxed hand position and during states of active use. These data were used to generate a measure of sensor activity across the splint surface. Through direct comparison with a commercial splint, the 3D printed splint was deemed to provide similar levels of support. Observation of the activity across the 16 sensors showed that active areas of the splint surface varied between tasks but were commonly focused at the base of the thumb. Our findings show promise in the ability to detect the changing forces imparted on the hand by the splint surface, objectively characterising their behaviour. This opens the opportunity for future study into the biomechanical effects of splints on arthritic thumbs to improve this important intervention and improve quality of life.
Collapse
|
10
|
Mbithi FM, Chipperfield AJ, Steer JW, Dickinson AS. Developing a control framework for self-adjusting prosthetic sockets incorporating tissue injury risk estimation and generalized predictive control. Biomed Eng Lett 2021; 12:59-73. [DOI: 10.1007/s13534-021-00211-x] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/01/2021] [Revised: 09/21/2021] [Accepted: 11/07/2021] [Indexed: 10/19/2022] Open
|
11
|
Ko ST, Asplund F, Zeybek B. A Scoping Review of Pressure Measurements in Prosthetic Sockets of Transfemoral Amputees during Ambulation: Key Considerations for Sensor Design. SENSORS (BASEL, SWITZERLAND) 2021; 21:5016. [PMID: 34372253 PMCID: PMC8347332 DOI: 10.3390/s21155016] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 05/07/2021] [Revised: 07/11/2021] [Accepted: 07/14/2021] [Indexed: 02/05/2023]
Abstract
Sensor systems to measure pressure at the stump-socket interface of transfemoral amputees are receiving increasing attention as they allow monitoring to evaluate patient comfort and socket fit. However, transfemoral amputees have many unique characteristics, and it is unclear whether existing research on sensor systems take these sufficiently into account or if it is conducted in ways likely to lead to substantial breakthroughs. This investigation addresses these concerns through a scoping review to profile research regarding sensors in transfemoral sockets with the aim of advancing and improving prosthetic socket design, comfort and fit for transfemoral amputees. Publications found from searching four scientific databases were screened, and 17 papers were found relating to the aim of this review. After quality assessment, 12 articles were finally selected for analysis. Three main contributions are provided: a de facto methodology for experimental studies on the implications of intra-socket pressure sensor use for transfemoral amputees; the suggestion that associated sensor design breakthroughs would be more likely if pressure sensors were developed in close combination with other types of sensors and in closer cooperation with those in possession of an in-depth domain knowledge in prosthetics; and that this research would be facilitated by increased interdisciplinary cooperation and open research data generation.
Collapse
Affiliation(s)
- Siu-Teing Ko
- Research and Innovation, Össur, 110 Reykjavík, Iceland
| | - Fredrik Asplund
- Department of Machine Design, KTH Royal Institute of Technology, 10044 Stockholm, Sweden;
| | - Begum Zeybek
- Healthcare Innovation Centre, School of Health and Life Sciences, Teesside University, Middlesbrough TS1 3BX, UK;
| |
Collapse
|
12
|
Investigation of Orthopedic Prosthesis Socket Management after Transfemoral Amputation by Expert Survey. PROSTHESIS 2021. [DOI: 10.3390/prosthesis3020015] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
Prosthesis treatment requires the close interaction of different actors. In fitting prostheses to patients, special attention is given to the manufacturing of the socket. The continuous development of the technologies involved in the fitting and optimization of prostheses is shown in the literature. The assessment of orthopedic technicians and their influence in the process is thus far largely unexplored. Ten orthopedic technicians were interviewed about the socket fitting process after transfemoral amputation. The research goal was to clarify the socket treatment process with regards to the German context. The results showed that the orthopedic technicians focussing on the patient during the fitting process. This study underlines the importance of interaction and empathy. Volume fluctuations are decisive within the treatment process and are interactively influenced by various factors. Furthermore, the research emphasizes the need for appropriate assistive technologies and the potential for the further development of existing systems.
Collapse
|
13
|
Safari R. Lower limb prosthetic interfaces: Clinical and technological advancement and potential future direction. Prosthet Orthot Int 2020; 44:384-401. [PMID: 33164655 DOI: 10.1177/0309364620969226] [Citation(s) in RCA: 22] [Impact Index Per Article: 4.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/03/2023]
Abstract
The human-prosthesis interface is one of the most complicated challenges facing the field of prosthetics, despite substantive investments in research and development by researchers and clinicians around the world. The journal of the International Society for Prosthetics and Orthotics, Prosthetics and Orthotics International, has contributed substantively to the growing body of knowledge on this topic. In celebrating the 50th anniversary of the International Society for Prosthetics and Orthotics, this narrative review aims to explore how human-prosthesis interfaces have changed over the last five decades; how research has contributed to an understanding of interface mechanics; how clinical practice has been informed as a result; and what might be potential future directions. Studies reporting on comparison, design, manufacturing and evaluation of lower limb prosthetic sockets, and osseointegration were considered. This review demonstrates that, over the last 50 years, clinical research has improved our understanding of socket designs and their effects; however, high-quality research is still needed. In particular, there have been advances in the development of volume and thermal control mechanisms with a few designs having the potential for clinical application. Similarly, advances in sensing technology, soft tissue quantification techniques, computing technology, and additive manufacturing are moving towards enabling automated, data-driven manufacturing of sockets. In people who are unable to use a prosthetic socket, osseointegration provides a functional solution not available 50 years ago. Furthermore, osseointegration has the potential to facilitate neuromuscular integration. Despite these advances, further improvement in mechanical features of implants, and infection control and prevention are needed.
Collapse
Affiliation(s)
- Reza Safari
- Health and Social Care Research Centre, University of Derby, Derby, UK
| |
Collapse
|
14
|
Lee H, Hong Y, Lee D, Hwang S, Lee G, Yang J, Yoon DS. Surface potential microscopy of surfactant-controlled single gold nanoparticle. NANOTECHNOLOGY 2020; 31:215706. [PMID: 32032003 DOI: 10.1088/1361-6528/ab73b7] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/07/2023]
Abstract
The surface potential of nanoparticles plays a key role in numerous applications, such as drug delivery and cellular uptake. The estimation of the surface potential of nanoparticles as drug carriers or contrast agents is important for the design of nanoparticle-based biomedical platforms. Herein, we report the direct measurement of the surface potential of individual gold nanorods (GNRs) via Kelvin probe force microscopy (KPFM) at the nanoscale. GNRs were capped by a surfactant, cetyltrimethylammonium bromide (CTAB), which was removed by centrifugation. CTAB removal is essential for GNR-based biomedical applications because of the cytotoxicity of CTAB. Applying KPFM analysis, we found that the mean surface potential of the GNRs became more negative as the CTAB was removed from the GNR. The results indicate that the negative charge of GNRs is covered by the electrostatic charge of the CTAB molecules. Similar trends were observed in experiments with gold nanospheres (GNS) capped by citrates. Overall, KPFM-based techniques characterize the surfactant of individual nanoparticles (i.e. GNR or GNS) with high resolution by mapping the surface potential of a single nanoparticle, which aids in designing engineered nanoparticles for biomedical applications.
Collapse
Affiliation(s)
- Hyungbeen Lee
- Center for BioMicrosystems, Korea Institute of Science and Technology, Seoul 02792, Republic of Korea
| | | | | | | | | | | | | |
Collapse
|
15
|
Salvino L, Chiu WK, Lynch J, Loh KJ. Special issue of biomedical engineering letters on advances in intelligent prostheses. Biomed Eng Lett 2020; 10:1-3. [PMID: 32175126 PMCID: PMC7046915 DOI: 10.1007/s13534-020-00150-z] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/25/2022] Open
Affiliation(s)
| | - Wing Kong Chiu
- Monash University School of Engineering, Clayton, Australia
| | | | | |
Collapse
|