1
|
Hengerer FH, Auffarth GU, Conrad-Hengerer I. 7-Year Efficacy and Safety of iStent inject Trabecular Micro-Bypass in Combined and Standalone Usage. Adv Ther 2024; 41:1481-1495. [PMID: 38363465 PMCID: PMC10960914 DOI: 10.1007/s12325-024-02788-y] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/17/2023] [Accepted: 01/17/2024] [Indexed: 02/17/2024]
Abstract
INTRODUCTION This study evaluated 7-year effectiveness and safety of second-generation trabecular micro-bypass implantation (iStent inject) either in combination with cataract surgery or as a standalone procedure (Combined or Standalone subgroups, respectively) in eyes with open-angle glaucoma. METHODS This prospective, non-randomized, unmasked, longitudinal study included 125 consecutive iStent inject cases of a single surgeon at a large German academic hospital. Patients had considerable preoperative disease burden, with mean intraocular pressure (IOP) of 23.5 mmHg, 84.8% of eyes on ≥ 2 medications, and 38.4% of eyes with prior glaucoma surgery. IOP, medications, adverse events, and secondary surgeries were assessed through 7 years in the Overall cohort and in Combined (n = 81) and Standalone (n = 44) subgroups. RESULTS Over 7-year follow-up, mean IOP decreased by 36.2-40.0% in Overall eyes, 34.1-38.9% in Combined eyes, and 39.5-43.5% in Standalone eyes (p < 0.001 at all timepoints for all groups). Meanwhile, mean medications decreased by 59.3-71.3% in Overall eyes, 57.9-69.0% in Combined eyes, and 62.1-76.2% in Standalone eyes (p < 0.001 at all timepoints in all groups). At last follow-up (mean 77.4 months; 92.8% of patients with last visit at 6 or 7 years), 83.7% of Overall eyes, 82.3% of Combined eyes, and 86.4% of Standalone eyes had achieved ≥ 20% IOP reduction vs preoperative. At last follow-up vs preoperative, 100% of eyes in all groups had the same or lower IOP and 100% had the same or lower medication regimen. Safety outcomes were favorable, with no filtration surgeries and only 4.84% of eyes experiencing clinically significant visual field loss over 7 years of follow-up. CONCLUSION iStent inject implantation with or without phacoemulsification produced significant and durable 7-year reductions in IOP (~ 34-44% reduction) and medications (~ 58-76% reduction) while preventing filtering surgery in this cohort of patients with relatively high preoperative disease burden. Combined and Standalone cases had similarly favorable effectiveness and safety.
Collapse
Affiliation(s)
- Fritz H Hengerer
- David J Apple International Laboratory of Ophthalmic Pathology, Department of Ophthalmology, International Vision Correction Research Centre (IVCRC), Buergerhospital, University of Heidelberg, Frankfurt, Germany.
- University Eye Hospital, University of Heidelberg, Im Neuenheimer Feld 400, 69120, Heidelberg, Germany.
| | - Gerd U Auffarth
- University Eye Hospital, University of Heidelberg, Im Neuenheimer Feld 400, 69120, Heidelberg, Germany
| | - Ina Conrad-Hengerer
- University Eye Hospital, University of Heidelberg, Im Neuenheimer Feld 400, 69120, Heidelberg, Germany
| |
Collapse
|
2
|
Coroneo MT, Graterol-Nisi G, Maver E, Gillies RM. Aqueous Humor Circulation in the Era of Minimally Invasive Surgery for Glaucoma. Ann Biomed Eng 2024; 52:898-907. [PMID: 38155316 DOI: 10.1007/s10439-023-03427-3] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/03/2023] [Accepted: 12/11/2023] [Indexed: 12/30/2023]
Abstract
Glaucoma surgery with implantation of aqueous humor draining microstents may compromise long-term corneal health by disrupting aqueous humor circulation. The effect of stent numbers on this circulation was interrogated to determine the number of stents associated with minimal circulation disruption. An in vitro anterior eye model perfusion system was constructed with multiple exit ports. A 3-D model of the anterior eye was imported into ABAQUS CFD, analyzes were carried out for unsteady laminar flow and solved using Navier-Stokes equations. DT Vision Foundry was used to analyze velocity contour plot images. The field variable results output for the CFD model were fluid wall shear, fluid pressure and fluid velocity. In vitro, "aqueous" fluid flow is high through a single stent and "aqueous" stagnation is greatest in the quadrants 180° away. Increasing stent port numbers, results in an exponential decrease in the stagnant flow locations. High wall shear stress was seen in the single stent model and is markedly reduced after a second and subsequent stents are introduced. We identify two factors potentially contributing to corneal compromise post glaucoma drainage surgery: aqueous humor stagnation, remote to the stent site and higher exit flows imparting increased stent exit shear stress (particularly with a single stent). With 4 stents, there is minimal disruption of anterior chamber circulation (mimicking physiological conditions). Furthermore we propose that aqueous humor circulation disruption via the usual single-exit port approach disrupts aqueous humor circulation with long-term consequences for corneal health.
Collapse
Affiliation(s)
- Minas T Coroneo
- Ophthalmic Surgeons, 2 St Pauls St, Randwick, NSW, 2031, Australia.
- Department of Ophthalmology, Prince of Wales Hospital/University of New South Wales, Sydney, Australia.
| | | | - Eric Maver
- Ophthalmic Surgeons, 2 St Pauls St, Randwick, NSW, 2031, Australia
| | - R Mark Gillies
- Medical Device Research Australia Pty Ltd, Sydney, Australia
| |
Collapse
|
3
|
Kim M, Rho S, Lim SH. Five-Year Outcomes of Single Trabecular Microbypass Stent (iStent ®) Implantation with Phacoemulsification in Korean Patients. Ophthalmol Ther 2023; 12:3281-3294. [PMID: 37792244 PMCID: PMC10640437 DOI: 10.1007/s40123-023-00824-8] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/22/2023] [Accepted: 09/19/2023] [Indexed: 10/05/2023] Open
Abstract
INTRODUCTION This study reports the long-term intraocular pressure (IOP)-lowering efficacy and safety of a single trabecular microbypass stent (iStent®; Glaukos Corp., San Clemente, CA, USA) for medically controlled open-angle glaucoma in Korean patients. METHODS This retrospective observational study included 42 eyes of 35 patients with primary open-angle glaucoma (POAG). All subjects underwent single first-generation iStent® implantation with phacoemulsification by a single surgeon with 5 years follow-up. The primary outcomes were changes in IOP and the number of antiglaucoma medications compared to the preoperative values. The secondary outcome was the proportion of eyes with IOP ≤ 18 mmHg without medication, ≤ 15 mmHg without medication, and ≤ 18 mmHg with or without medication. Adverse events and need for secondary glaucoma surgery were also recorded. RESULTS The mean IOP decreased from 15.8 ± 2.8 to 13.8 ± 1.7 mmHg and the mean number of medications was reduced from 2.24 ± 1.18 to 0.83 ± 1.12, respectively, at year 5. At 3 and 5 years, 80.6% and 78.6% of eyes, respectively, were receiving fewer medications than preoperative numbers. In contrast, only 50% of eyes on four preoperative medications showed medication reductions at 5 years. At years 3 and 5, 61.3% and 53.5% of eyes achieved IOP ≤ 18 mmHg without medication, whereas 90.3% and 89.3% of eyes achieved ≤ 18 mmHg regardless of medication use, respectively. Four eyes required additional glaucoma surgery (two Ahmed glaucoma valve implantations, one trabeculectomy, and one XEN 45 Gel Stent implantation), and all were receiving four preoperative antiglaucoma medications. Transient IOP elevation (14.3%) was the most common complication, followed by five hyphema, one stent obstruction, one stent malposition, and one severe anterior chamber reaction. CONCLUSION This study demonstrated a good safety profile and sustained IOP reduction after the implantation of a single trabecular microbypass stent (iStent®) with phacoemulsification in Korean patients. The majority of subjects with POAG showed a relatively good response; however, eyes receiving a higher number of medications preoperatively (especially four medications) had difficulty achieving a low target IOP.
Collapse
Affiliation(s)
- Myungjin Kim
- Department of Ophthalmology, CHA Bundang Medical Center, CHA University, Seongnam, South Korea
| | - Seungsoo Rho
- Department of Ophthalmology, CHA Bundang Medical Center, CHA University, Seongnam, South Korea
| | - Su-Ho Lim
- Department of Ophthalmology, Daegu Veterans Health Service Medical Center, #60 Wolgok-Ro, Dalseo-Gu, Daegu, 42835, Republic of Korea.
| |
Collapse
|
4
|
Ang BCH, Lim SY, Betzler BK, Wong HJ, Stewart MW, Dorairaj S. Recent Advancements in Glaucoma Surgery-A Review. Bioengineering (Basel) 2023; 10:1096. [PMID: 37760198 PMCID: PMC10525614 DOI: 10.3390/bioengineering10091096] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/06/2023] [Revised: 09/10/2023] [Accepted: 09/11/2023] [Indexed: 09/29/2023] Open
Abstract
Surgery has long been an important treatment for limiting optic nerve damage and minimising visual loss in patients with glaucoma. Numerous improvements, modifications, and innovations in glaucoma surgery over recent decades have improved surgical safety, and have led to earlier and more frequent surgical intervention in glaucoma patients at risk of vision loss. This review summarises the latest advancements in trabeculectomy surgery, glaucoma drainage device (GDD) implantation, and minimally invasive glaucoma surgery (MIGS). A comprehensive search of MEDLINE, EMBASE, and CENTRAL databases, alongside subsequent hand searches-limited to the past 10 years for trabeculectomy and GDDs, and the past 5 years for MIGS-yielded 2283 results, 58 of which were included in the final review (8 trabeculectomy, 27 GDD, and 23 MIGS). Advancements in trabeculectomy are described in terms of adjunctive incisions, Tenon's layer management, and novel suturing techniques. Advancements in GDD implantation pertain to modifications of surgical techniques and devices, novel methods to deal with postoperative complications and surgical failure, and the invention of new GDDs. Finally, the popularity of MIGS has recently promoted modifications to current surgical techniques and the development of novel MIGS devices.
Collapse
Affiliation(s)
- Bryan Chin Hou Ang
- Department of Ophthalmology, National Healthcare Group Eye Institute, Tan Tock Seng Hospital, Singapore 308433, Singapore
- Department of Ophthalmology, National Healthcare Group Eye Institute, Woodlands Health Campus, Singapore 737628, Singapore
| | - Sheng Yang Lim
- Department of Ophthalmology, National Healthcare Group Eye Institute, Tan Tock Seng Hospital, Singapore 308433, Singapore
| | - Bjorn Kaijun Betzler
- Department of Surgery, Tan Tock Seng Hospital, National Healthcare Group, Singapore 308433, Singapore
- Yong Loo Lin School of Medicine, National University of Singapore, Singapore 119077, Singapore
| | - Hon Jen Wong
- Yong Loo Lin School of Medicine, National University of Singapore, Singapore 119077, Singapore
| | - Michael W. Stewart
- Department of Ophthalmology, Mayo Clinic, Jacksonville, FL 32224, USA; (M.W.S.)
| | - Syril Dorairaj
- Department of Ophthalmology, Mayo Clinic, Jacksonville, FL 32224, USA; (M.W.S.)
| |
Collapse
|
5
|
Qin M, Yu-Wai-Man C. Glaucoma: Novel antifibrotic therapeutics for the trabecular meshwork. Eur J Pharmacol 2023; 954:175882. [PMID: 37391006 PMCID: PMC10804937 DOI: 10.1016/j.ejphar.2023.175882] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/03/2023] [Revised: 06/23/2023] [Accepted: 06/26/2023] [Indexed: 07/02/2023]
Abstract
Glaucoma is a chronic and progressive neurodegenerative disease characterized by the loss of retinal ganglion cells and visual field defects, and currently affects around 1% of the world's population. Elevated intraocular pressure (IOP) is the best-known modifiable risk factor and a key therapeutic target in hypertensive glaucoma. The trabecular meshwork (TM) is the main site of aqueous humor outflow resistance and therefore a critical regulator of IOP. Fibrosis, a reparative process characterized by the excessive deposition of extracellular matrix components and contractile myofibroblasts, can impair TM function and contribute to the pathogenesis of primary open-angle glaucoma (POAG) as well as the failure of minimally invasive glaucoma surgery (MIGS) devices. This paper provides a detailed overview of the current anti-fibrotic therapeutics targeting the TM in glaucoma, along with their anti-fibrotic mechanisms, efficacy as well as the current research progress from pre-clinical to clinical studies.
Collapse
Affiliation(s)
- Mengqi Qin
- King's College London, London, SE1 7EH, UK
| | | |
Collapse
|
6
|
Gallardo MJ, Porter M. Efficacy and Safety of Pairing iStent Inject Trabecular Micro-Bypass and iAccess Precision Blade Goniotomy in Patients with Open-Angle Glaucoma. Ophthalmol Ther 2023; 12:1973-1987. [PMID: 37178443 PMCID: PMC10287603 DOI: 10.1007/s40123-023-00726-9] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/10/2023] [Accepted: 04/24/2023] [Indexed: 05/15/2023] Open
Abstract
INTRODUCTION This study evaluated efficacy and safety of implanting two second-generation trabecular micro-bypass stents (iStent inject/iStent inject W) with phacoemulsification, either with or without iAccess Precision Blade goniotomy, in patients with mild-to-moderate open-angle glaucoma (OAG). METHODS This retrospective, non-randomized, unmasked, dual-arm, single-site, multi-surgeon, consecutive case series evaluated all OAG eyes that underwent phacoemulsification and iStent inject implantation either as a dual procedure (group A) or paired with iAccess goniotomy (group B) from July 2020 to May 2022. Effectiveness outcomes analyzed from 1 month onward included intraocular pressure (IOP), proportions of eyes with IOP ≤ 12/≤ 15/≤ 18, proportion medication-free, and medication number. Safety outcomes at all timepoints included adverse events and secondary surgeries. RESULTS In group A, mean IOP reduced from 14.9 ± 3.2 mmHg on 1.22 ± 1.31 mean medications preoperatively (n = 63) to 13.5 ± 2.5 mmHg on 0.24 ± 0.61 medications at month 3 (n = 34; p = 0.048 IOP, p < 0.001 medications). In group B, mean IOP reduced from 16.0 ± 4.2 mmHg on 1.12 ± 1.07 medications preoperatively (n = 93) to 12.2 ± 2.3 mmHg on 0.57 ± 1.27 medications at month 3 (n = 23; p < 0.001 IOP, p = 0.003 medications). From preoperative to 3 months, the percent of eyes with IOP ≤ 12 mmHg remained at 32.4% in group A (p = 1.0) and rose from 21.7% to 60.9% in group B (p = 0.0177); eyes with IOP ≤ 15 mmHg rose from 52.9% to 76.5% in group A (p = 0.0963) and from 43.5% to 91.3% in group B (p = 0.0034). Adjusting for baseline between-group differences, group B had significantly greater postoperative IOP reduction than group A (p = 0.043); medication reductions were similar. Safety was favorable in both groups. CONCLUSIONS Phacoemulsification and iStent inject with or without iAccess Precision Blade goniotomy produced clinically meaningful and safe IOP and medication reductions. The paired iStent inject + iAccess + phacoemulsification procedure enabled greater IOP reduction and lower IOP thresholds than iStent inject + phacoemulsification. The study provides some of the first data on this paired approach and on the novel iAccess Precision Blade.
Collapse
Affiliation(s)
- Mark J. Gallardo
- El Paso Eye Surgeons, PA, 1201 North Mesa Street, Suite G, El Paso, TX 79902 USA
- Department of Ophthalmology, Texas Tech University Health Sciences Center in Lubbock, 3601, 4th St, Lubbock, TX 79430 USA
| | - Matthew Porter
- El Paso Eye Surgeons, PA, 1201 North Mesa Street, Suite G, El Paso, TX 79902 USA
- Department of Ophthalmology, Texas Tech University Health Sciences Center in Lubbock, 3601, 4th St, Lubbock, TX 79430 USA
| |
Collapse
|
7
|
Wagner IV, Ang B, Checo L, Simsek D, Draper C, Dorairaj S. Spotlight on Schlemm's Canal MicroStent Injection in Patients with Glaucoma. Clin Ophthalmol 2023; 17:1557-1564. [PMID: 37288002 PMCID: PMC10243342 DOI: 10.2147/opth.s388293] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/22/2023] [Accepted: 05/30/2023] [Indexed: 06/09/2023] Open
Abstract
Minimally invasive glaucoma surgery (MIGS) has revolutionized glaucoma care with its favorable safety profile and ability to delay or minimize the need for traditional, bleb-based procedures. Microstent device implantation is a type of angle-based MIGS, which reduces intraocular pressure (IOP) through bypass of the juxtacanalicular trabecular meshwork (TM) and facilitation of aqueous outflow into the Schlemm's canal. Although there are limited microstent devices on the market, multiple studies have evaluated the safety and efficacy of iStent® (Glaukos Corp.), iStent Inject® (Glaukos Corp.), and Hydrus® Microstent (Alcon) in the treatment of mild-to-moderate open-angle glaucoma, with and without concurrent phacoemulsification. This review attempts to provide a comprehensive evaluation of injectable angle-based microstent MIGS devices in the treatment of glaucoma.
Collapse
Affiliation(s)
| | - Bryan Ang
- Department of Ophthalmology, Tan Tock Seng Hospital, Singapore
| | - Leticia Checo
- Department of Ophthalmology, Mayo Clinic, Jacksonville, FL, USA
| | - Derya Simsek
- Department of Ophthalmology, Baskent University Medical School, Ankara, Turkey
| | | | - Syril Dorairaj
- Department of Ophthalmology, Mayo Clinic, Jacksonville, FL, USA
| |
Collapse
|
8
|
Effectiveness and Safety of iStent Infinite Trabecular Micro-Bypass for Uncontrolled Glaucoma. J Glaucoma 2023; 32:9-18. [PMID: 36260288 PMCID: PMC9722368 DOI: 10.1097/ijg.0000000000002141] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/13/2022] [Accepted: 10/07/2022] [Indexed: 01/24/2023]
Abstract
PRCIS The iStent Infinite Trabecular Micro-Bypass System implanted in patients with open angle glaucoma (OAG) (uncontrolled by prior surgical or medical therapy) was effective in reducing mean diurnal intraocular pressure with a favorable safety profile. PURPOSE The purpose of this study is to evaluate safety and effectiveness of the iStent infinite Trabecular Micro-Bypass System in patients with OAG uncontrolled by prior surgical or medical therapy. DESIGN Prospective, multicenter, single-arm, open-label clinical trial. METHODS Implantation of iStent infinite (3 iStent inject W stents) was performed as a stand-alone surgical procedure in eyes with OAG uncontrolled by prior incisional or cilioablative surgeries or maximum tolerated medical therapy (MTMT). Prospectively declared effectiveness endpoints were proportion of eyes achieving ≥20% mean diurnal intraocular pressure (MDIOP) reduction from baseline at month 12 on the same or fewer intraocular pressure (IOP)-lowering medication classes (responder endpoint) and mean change in MDIOP from baseline at month 12. Safety parameters included visual acuity, slit-lamp and fundus examinations, gonioscopy, perimetry, surgical complications, and adverse events. RESULTS Seventy-two eyes of 72 patients (mean age 71.9 y) with preoperative mean medicated MDIOP of 23.4±2.8 mm Hg on a mean of 3.1±0.9 IOP-lowering medication classes were enrolled: 61 eyes with failed prior surgery/ies (Failed-Surgery subgroup) and 11 eyes uncontrolled on MTMT (MTMT subgroup). A total of 76.1% of all enrolled patients met the responder endpoint (73.4% Failed-Surgery, 90.9% MTMT), with mean reduction (SE) in MDIOP at month 12 of 5.9(0.6) mm Hg [5.5(0.7) mm Hg Failed-Surgery subgroup, 8.1(0.9) mm Hg MTMT subgroup]. For patients on the same or fewer medication(s) as baseline, 53.0% achieved ≥30% MDIOP reduction without surgical interventions/other events. Safety was favorable, with no explants, infection, or device-related interventions or hypotony. CONCLUSIONS iStent infinite stand-alone surgery achieved clinically significant IOP reduction and favorable safety in patients with OAG uncontrolled by prior therapy.
Collapse
|