1
|
Borkenstein AF, Borkenstein EM, Omidi P, Langenbucher A. Image Contrast and Spectral Transmission of Presbyopia-Correcting Intraocular Lenses: Evaluating the Impact of Nd:YAG Laser Associated Defects. Curr Eye Res 2025; 50:51-57. [PMID: 39139124 DOI: 10.1080/02713683.2024.2391382] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/29/2024] [Revised: 06/28/2024] [Accepted: 08/06/2024] [Indexed: 08/15/2024]
Abstract
PURPOSE Neodymium yttrium aluminum garnet (Nd:YAG) laser capsulotomy is considered gold standard in the treatment of posterior capsule opacification (PCO). In this laboratory study, we measured spectral transmission to evaluate the image contrast and analyze the impact of Nd:YAG associated defects in presbyopia-correcting intraocular lenses (IOLs). METHODS Two hydrophobic, acrylic IOLs as classic multifocal lenses with diffractive ring segments and different amount of near addition (A, B), one hydrophilic, trifocal IOL (C), one sector-shaped, plate haptic IOL (D) and one hydrophobic, enhanced depth of focus (EDOF) IOL (E) were studied. Measurements included surface topography characterization, United States Air Force resolution test chart (USAF) analysis, spectral transmittance measurements and through focus contrast measurement. Measurements were done with unaltered samples, damages (n = 7) were intentionally created in the central 3.5 mm zone using a photodisruption laser (2.0 mJ) and measurements were repeated. RESULTS Significant differences were shown between unmodified samples and samples with YAG pits. The YAG-pits decreased the image contrast and spectral transmission and changed results of USAF test images. The imaging contrast decreased to 66%, 64%, 60%, 52% and 59% with the YAG shots in samples (A-E). The light transmission decreased to 88%, 87%, 92%, 79% and 91% (A-E) on average between 400 nm to 800 nm. In all IOLs a reduction of the relative intensity of transmitted light was observed. CONCLUSION The image performance of all tested presbyopia-correcting IOLs is significantly influenced and disturbed by YAG-pits. The intensity of transmitted light is reduced in the wavelength between 450-800 nm. USAF test targets show worse results compared to unmodified samples and contrast is significantly deteriorated. No ranking/rating among tested IOLs should be made as many other factors play a role in real world scenario. High care should be taken when performing Nd:YAG capsulotomy on premium IOLs to avoid any damages.
Collapse
Affiliation(s)
| | | | - Pooria Omidi
- Institute of Experimental Ophthalmology, Saarland University, Homburg, Germany
| | - Achim Langenbucher
- Institute of Experimental Ophthalmology, Saarland University, Homburg, Germany
| |
Collapse
|
2
|
Borkenstein AF, Kormilina TK, Fitzek H, Rattenberger J, Kothleitner G, Charry FEM, Borkenstein EM. Incorrectly Focused Neodymium:Yttrium-Aluminum-Garnet (Nd:YAG) Laser Beam Leads to Massive Destructive Effects in Small-Aperture (Pinhole) Intraocular Lenses. Ophthalmol Ther 2024; 13:2745-2758. [PMID: 39153117 PMCID: PMC11408416 DOI: 10.1007/s40123-024-01007-9] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/18/2024] [Accepted: 07/17/2024] [Indexed: 08/19/2024] Open
Abstract
INTRODUCTION Pinhole intraocular lenses (IOLs) were developed to improve reading by compensating for loss of accommodative function. The IC-8® Apthera™ is a small-aperture presbyopia-correcting IOL that combines the proven principle of small-aperture optics with an aspheric monofocal lens to deliver a continuous range of vision for patients with cataracts from distance to near vision. Posterior capsule opacification is the most common sequela after cataract surgery. It is effectively treated by laser capsulotomy. However, if the laser beam is incorrectly focused, the IOL can be permanently damaged (pits/shots). METHODS In this experimental study, yttrium-aluminum-garnet (YAG) pits were purposefully created. Defects were analyzed and compared between the periphery of the ring in the clear area of the hydrophobic acrylic lens and at the carbon black (CB)-polyvinylidene fluoride (PVDF) filtering component (FilterRing™) of the pinhole lens. All defects were made using identical settings/energy levels (2.6 mJ). The damage induced to the IC-8® Apthera™ IOL was examined by low-magnification images, light microscopy, scanning electron microscopy, and micro-computed tomography (micro-CT). RESULTS YAG defects in the carbon black filter ring were much more severe than those in the clear zone due to the high absorption of the carbon black. Massive defects and destruction of the lens with tearing out of fragments and particles were observed. The missing volume calculated from the micro-CT reconstruction was 0.266 mm3, which is 1.6% of the entire IOL volume, or more than 1000 times the volume damaged in the largest shot in the periphery. CONCLUSION Based on the results, we highly recommend using the lowest possible energy levels, posterior offset setting, and circular pattern for maximum safety when performing laser capsulotomy with pinhole implants. Care should be taken to avoid creating irreversible iatrogenic defects that may affect overall quality. The safest area for performing capsulotomy seems to be the periphery of the ring segment. Video available for this article.
Collapse
Affiliation(s)
- Andreas F Borkenstein
- Borkenstein and Borkenstein Private Practice, Privatklinik Der Kreuzschwestern Graz, Kreuzgasse 35, 8010, Graz, Austria.
| | - Tatiana K Kormilina
- Graz Centre for Electron Microscopy (ZFE), Steyrergasse 17, 8010, Graz, Austria
| | - Harald Fitzek
- Graz Centre for Electron Microscopy (ZFE), Steyrergasse 17, 8010, Graz, Austria
| | | | - Gerald Kothleitner
- Graz Centre for Electron Microscopy (ZFE), Steyrergasse 17, 8010, Graz, Austria
- Institute of Electron Microscopy and Nanoanalysis (FELMI), Graz University of Technology, Steyrergasse 17, 8010, Graz, Austria
| | - Fabio E Machado Charry
- Institute of Solid State Physics, University of Technology Graz, Petersgasse 16/2, 8010, Graz, Austria
| | - Eva-Maria Borkenstein
- Borkenstein and Borkenstein Private Practice, Privatklinik Der Kreuzschwestern Graz, Kreuzgasse 35, 8010, Graz, Austria
| |
Collapse
|
3
|
Borkenstein AF, Borkenstein EM. Neodymium-doped yttrium aluminum garnet (Nd: YAG) laser treatment in ophthalmology: a review of the most common procedures Capsulotomy and Iridotomy. Lasers Med Sci 2024; 39:167. [PMID: 38954050 DOI: 10.1007/s10103-024-04118-8] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/18/2023] [Accepted: 06/24/2024] [Indexed: 07/04/2024]
Abstract
Nowadays, lasers are used in various medical fields. Ophthalmology was the first medical specialty to utilize lasers in patient treatment and still remains the leading medical field that uses laser energy for both therapeutic and diagnostic purposes. The neodymium: yttrium-aluminum-garnet (Nd: YAG) laser is one of the most common lasers used in ophthalmology. It is a solid-state laser with a wavelength of 1064 nm that works on the principle of photodisruption. Since its introduction in ophthalmology over 40 years ago, it has found various applications, mainly for procedures where cutting or disruption of ocular tissue is required. Compared to surgical alternatives, the use of Nd: YAG lasers on ocular tissue is minimally invasive. In this review, we focus on the two most common ophthalmic applications of Nd: YAG laser - laser peripheral iridotomy and posterior capsulotomy. The history of the techniques, current trends, potential complications, and the prognosis for future use is discussed.
Collapse
Affiliation(s)
- Andreas F Borkenstein
- Borkenstein and Borkenstein, Private Practice at Privatklinik Kreuzschwestern Graz, Ophthalmology, Kreuzgasse 35, Graz, 8010, Austria.
| | - Eva-Maria Borkenstein
- Borkenstein and Borkenstein, Private Practice at Privatklinik Kreuzschwestern Graz, Ophthalmology, Kreuzgasse 35, Graz, 8010, Austria
| |
Collapse
|
4
|
Borkenstein AF, Mikitisin A, Schwedt A, Borkenstein EM, Mayer J. A Novel 3D High Resolution Imaging Method Using Correlative X-Ray and Electron Microscopy to Study Neodymium-Doped Yttrium Aluminum Garnet Laser-Induced Defects in Intraocular Lenses. Ophthalmic Res 2024; 67:292-300. [PMID: 38718759 DOI: 10.1159/000539243] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/25/2024] [Accepted: 05/01/2024] [Indexed: 06/06/2024]
Abstract
INTRODUCTION Cataract extraction is the most frequently performed ophthalmological procedure worldwide. Posterior capsule opacification remains the most common consequence after cataract surgery and can lead to deterioration of the visual performance with cloudy, blurred vision and halo, glare effects. Neodymium-doped yttrium aluminum garnet (Nd:YAG) laser capsulotomy is the gold standard treatment and a very effective, safe and fast procedure in removing the cloudy posterior capsule. Damaging the intraocular lens (IOL) during the treatment may occur due to wrong focus of the laser beam. These YAG-pits may lead to a permanent impairment of the visual quality. METHODS In an experimental study, we intentionally induced YAG pits in hydrophilic and hydrophobic acrylic IOLs using a photodisruption laser with 2.6 mJ. This experimental study established a novel 3D imaging method using correlative X-ray and scanning electron microscopy (SEM) to characterize these damages. By integrating the information obtained from both X-ray microscopy and SEM, a comprehensive picture of the materials structure and performance could be established. RESULTS It could be revealed that although the exact same energies were used to all samples, the observed defects in the tested lenses showed severe differences in shape and depth. While YAG pits in hydrophilic samples range from 100 to 180 µm depth with a round shape tip, very sharp tipped defects up to 250 µm in depth were found in hydrophobic samples. In all samples, particles/fragments of the IOL material were found on the surface that were blasted out as a result of the laser shelling. CONCLUSION Defects in hydrophilic and hydrophobic acrylic materials differ. Material particles can detach from the IOL and were found on the surface of the samples. The results of the laboratory study illustrate the importance of a precise and careful approach to Nd:YAG capsulotomy in order to avoid permanent damage to the IOL. The use of an appropriate contact glass and posterior offset setting to increase safety should be carried out routinely.
Collapse
Affiliation(s)
- Andreas F Borkenstein
- Borkenstein and Borkenstein Private Practice, Privatklinik der Kreuzschwestern Graz, Graz, Austria
| | - Adrian Mikitisin
- RWTH Aachen University, Gemeinschaftslabor für Elektronenmikroskopie, Aachen, Germany
| | - Alexander Schwedt
- RWTH Aachen University, Gemeinschaftslabor für Elektronenmikroskopie, Aachen, Germany
| | - Eva-Maria Borkenstein
- Borkenstein and Borkenstein Private Practice, Privatklinik der Kreuzschwestern Graz, Graz, Austria
| | - Joachim Mayer
- RWTH Aachen University, Gemeinschaftslabor für Elektronenmikroskopie, Aachen, Germany
| |
Collapse
|
5
|
Borkenstein AF, Borkenstein EM, Omidi P, Langenbucher A. Image Contrast and Spectral Transmission in Intraocular Lenses with Nd:YAG Pits. Curr Eye Res 2023; 48:911-918. [PMID: 37382106 DOI: 10.1080/02713683.2023.2229540] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/20/2023] [Accepted: 06/20/2023] [Indexed: 06/30/2023]
Abstract
PURPOSE Neodymium yttrium aluminum garnet (Nd:YAG) laser capsulotomy is considered as safe and effective method in the treatment of posterior capsule opacification. Nevertheless, side effects are described. The incorrectly adjusted focus of the laser beam during the procedure can lead to so-called YAG-pits or YAG-shots. In this experimental study, we measured spectral transmission to evaluate the image contrast and analyze the impact of YAG-pits in intraocular lenses (IOL). METHODS Acrylic, foldable, one-piece IOLs with 6.0 mm optic and different material properties were studied. These included: monofocal IOLs and enhanced monofocal IOLs with water content of 0.3%, 26.0%, and 4.0% and a refractive index of 1.49, 1.46, and 1.54, respectively. All measurements were done with new, unaltered IOLs and IOLs with YAG-pits. Damage was intentionally created, performing YAG-pits (n = 7) in the central zone (3.5 mm) using a photodisruption laser (2.0mJ). All laboratory measurements were repeated: These included surface topography characterization, United States Air Force (USAF) resolution test chart analysis, spectral transmittance measurements and through focus contrast measurement. RESULTS Significant differences were found between the unaltered lenses and lenses with defects. The YAG-pits within the optic of the IOLs decreased the image contrast and spectral transmission and changed results of USAF test images at the focal position by 62%, 57% and 54%, respectively. In all IOLs a reduction of the relative intensity of total transmitted light was observed between 450 and 700 nm wavelength. CONCLUSION This experimental study confirmed that the IOL image performance deteriorates with YAG-pits. The total intensity of transmitted light or transmittance (without scattering) was reduced in the wavelength between 450 and 700 nm. The contrast was significantly reduced and USAF test targets showed much worse results compared to unmodified counterparts. There was no systematic difference between monofocal and enhanced monofocal lenses. Further experiments should investigate the effect of YAG-pits on diffractive IOLs.
Collapse
Affiliation(s)
- A F Borkenstein
- Borkenstein & Borkenstein Private Practice, Privatklinik der Kreuzschwestern Graz, Graz, Austria
| | - E M Borkenstein
- Borkenstein & Borkenstein Private Practice, Privatklinik der Kreuzschwestern Graz, Graz, Austria
| | - P Omidi
- Institute of Experimental Ophthalmology, Saarland University, Homburg, Germany
| | - A Langenbucher
- Institute of Experimental Ophthalmology, Saarland University, Homburg, Germany
| |
Collapse
|
6
|
Borkenstein AF, Borkenstein EM, Mühlbacher I, Flock M. Nano-Indentation to Determine Mechanical Properties of Intraocular Lenses: Evaluating Penetration Depth, Material Stiffness, and Elastic Moduli. Ophthalmol Ther 2023; 12:2087-2101. [PMID: 37211587 PMCID: PMC10287600 DOI: 10.1007/s40123-023-00728-7] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/18/2023] [Accepted: 04/28/2023] [Indexed: 05/23/2023] Open
Abstract
INTRODUCTION Intraocular lenses (IOL) should remain in the eye for life after implantation into the capsular bag during cataract surgery. The material must meet various requirements. It is crucial that the material has the best biocompatibility, and it should be flexible and soft for best possible implantation process but also sufficiently stable and stiff for good centering in the eye and posterior capsule opacification prevention. METHODS In this laboratory experiment, we used nano-indentation for the mechanical assessment of three hydrophobic acrylic (A, B, C), three hydrophilic acrylic (D, E, F), and one silicone (G) intraocular lens. We wanted to determine whether some react more sensitively to touching/handling than others. The indentation elastic modulus and the creep were obtained from the force displacement curve. For measuring penetration depth and testing of possible damage to the intraocular lenses, the samples were measured at room temperature. A 200-µm-diameter ruby spherical tipped indenter was used for all the tests. Indentations were made to three different maximum loads, namely 5 mN (milli Newton), 15 mN, and 30 mN and repeated three times. RESULTS The lowest penetration depth (12 µm) was observed with IOL B. However, IOL A, D, and F showed similar low penetration depths (20, 18, and 23 µm, respectively). Lenses C and E showed slightly higher penetration depths of 36 and 39 µm, respectively. The silicone lens (G) showed the greatest penetration depth of 54.6 µm at a maximum load of 5 mN. With higher maximal loads (15 and 30 mN) the penetration depth increased significantly. Lens C, however, showed the same results at both 15 and 30 mN with no increase of penetration depth. This seems to fit well with the material and manufacturing process of the lens (lathe-cut). During the holding time of 30 s at constant force all six acrylic lenses showed a significant increase of the creep (CIT 21-43%). Lens G showed the smallest creep with 14%. The mean indentation modulus (EIT) values ranged from 1 to 37 MPa. IOL B had the largest EIT of 37 MPa, which could be caused by the low water content. CONCLUSION It was found that results correlate very well with the water content of the material in the first place. The manufacturing process (molded versus lathe-cut) seems to play another important role. Since all included acrylic lenses are very similar, it was not surprising that the measured differences are marginal. Even though hydrophobic materials with lower water content showed higher relative stiffness, penetration and defects can also occur with these. The surgeon and scrub nurse should always be aware that macroscopic changes are difficult to detect but that defects could theoretically lead to clinical effects. The principle of not touching the center of the IOL optic at any time should be taken seriously.
Collapse
Affiliation(s)
- Andreas F Borkenstein
- Borkenstein & Borkenstein Private Practice, Privatklinik der Kreuzschwestern Graz, Kreuzgasse 35, 8010, Graz, Austria.
| | - Eva-Maria Borkenstein
- Borkenstein & Borkenstein Private Practice, Privatklinik der Kreuzschwestern Graz, Kreuzgasse 35, 8010, Graz, Austria
| | - Inge Mühlbacher
- Institute of Inorganic Chemistry, University of Technology Graz, Stremayrgasse 9, 8010, Graz, Austria
| | - Michaela Flock
- Institute of Inorganic Chemistry, University of Technology Graz, Stremayrgasse 9, 8010, Graz, Austria
| |
Collapse
|
7
|
Borkenstein AF, Borkenstein EM, Omidi P, Langenbucher A. Evaluating impact of Nd: YAG laser associated defects on optical quality of hydrophilic and hydrophobic intraocular lenses using visualization of light propagation and USAF test targets. BMC Ophthalmol 2022; 22:494. [PMID: 36527032 PMCID: PMC9756656 DOI: 10.1186/s12886-022-02738-8] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/27/2022] [Accepted: 12/13/2022] [Indexed: 12/23/2022] Open
Abstract
BACKGROUND Neodymium:yttrium aluminum garnet (Nd:YAG) laser capsulotomy is a well-accepted, safe, and effective measure in the treatment of posterior capsule opacification. However, iatrogenic intraocular lens damage is a relatively common side effect that happens due to inappropriate focusing during the procedure. This experimental study analyzes the impact of YAG-pits to obtain qualitative information. METHODS Acrylic, monofocal hydrophilic and hydrophobic intraocular lenses (IOLs) with 6.0 mm optic and the with the same power (21D) were studied. First, all measurements were done with unmodified IOLs. Damage was intentionally created, performing YAG-pits (n = 5) in the central area of the lens optic (3.0 mm) using a photodisruption laser with the same energy level of 1.8 mJ. To simulate the cruciate pattern, the 5 defects were created in a cross shape within the 3.0 mm optical zone. Afterwards, all laboratory measurements were repeated: These included the United States Air Force (USAF) resolution test chart to study the imaging performance of the IOL, light field measurements to show the course of the rays behind the IOL and the modulation transfer function (MTF) measurements were analyzed. RESULTS Evaluating USAF showed that unmodified lenses produced a sharper image. Damaged lenses led to a more blurred image and to the impression of a lower contrast with a kind of halo/glare effect. The light field measurement showed that YAG-pits led to a kind of dispersion and scattering effect, which was higher in hydrophobic IOLs. MTF showed a deterioration in damaged hydrophilic and hydrophobic IOLs, respectively. CONCLUSION Our experimental study confirms that YAG-pits can reduce imaging quality of intraocular lenses. These defects behave as a new Huygens source, distribute a spherical wave that additionally illuminate the background of the USAF target. It can be assumed that material properties of the IOL (water content, refractive index) play an important role and affect results. The impact level is strongly dependent on the number, size and position of YAG-pits within the optic. LIMITATION Only monofocal IOLs have been investigated so far, further tests with various IOL optics have to follow. In addition, simulating the circular pattern of YAG capsulotomy is necessary.
Collapse
Affiliation(s)
- A. F. Borkenstein
- Borkenstein & Borkenstein private practice, Privatklinik der Kreuzschwestern Graz, Kreuzgasse 35, 8010 Graz, Austria
| | - E. M. Borkenstein
- Borkenstein & Borkenstein private practice, Privatklinik der Kreuzschwestern Graz, Kreuzgasse 35, 8010 Graz, Austria
| | - P. Omidi
- grid.11749.3a0000 0001 2167 7588Institut für Experimentelle Ophthalmologie, Universität des Saarlandes, Saar 66424 Homburg, Deutschland
| | - A. Langenbucher
- grid.11749.3a0000 0001 2167 7588Institut für Experimentelle Ophthalmologie, Universität des Saarlandes, Saar 66424 Homburg, Deutschland
| |
Collapse
|