1
|
Giannoudis PV, Andrzejwski P, Chloros G, Hensor EMA. Safety and performance of a novel synthetic biomimetic scaffold for iliac crest defect reconstruction during surgical treatment of pelvic girdle pain: a first-in-human trial. Br Med Bull 2025; 153:ldae023. [PMID: 39821211 PMCID: PMC11738167 DOI: 10.1093/bmb/ldae023] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/25/2024] [Revised: 12/05/2024] [Accepted: 12/13/2024] [Indexed: 01/19/2025]
Abstract
INTRODUCTION Surgical treatment of pelvic girdle pain (PGP) involves arthrodesis of sacroiliac (SI) and pubic symphysis joints. Fusion of pubic symphysis involves the implantation of an autologous iliac crest tricortical graft harvested from the iliac crest. The objective was to assess the safety of a novel synthetic graft substitute (b.Bone) for iliac crest reconstruction and to evaluate the results of PGP surgical treatment. SOURCES OF DATA Consecutive participants undergoing pelvic fusion and requiring iliac crest reconstruction were enrolled and followed-up for 12 months in a prospective first-in-human clinical investigation. Adverse events were documented, and health-related quality of life was evaluated using EuroQol-5D-5L questionnaire. Iliac crest defect healing was evaluated by the Modified Lane and Sandhu radiological scoring system. In addition, relevant published peer-reviewed scientific articles identified from PubMed. AREAS OF AGREEMENT The EQ-5D-5L scores improved steadily reaching the highest point at 365 days. By 365 days complete healing of the bone defect was observed. AREAS OF CONTROVERSY The management of PGP remains challenging with mixed results reported in the literature. GROWING POINTS While there is lack of consensus on how to manage PGP, the present study shows improved outcomes at one year following surgery. The synthetic b.Bone scaffold is a safe option with good healing outcomes for iliac crest defect reconstruction. AREAS TIMELY FOR DEVELOPING RESEARCH Although b.Bone synthetic scaffold found to be safe, further studies reporting on surgical treatment of PGP are required to confirm the findings in comparative trials.
Collapse
Affiliation(s)
- Peter V Giannoudis
- Academic Department of Trauma & Orthopaedics, School of Medicine, University of Leeds, Leeds, UK
- Leeds Institute of Rheumatic and Musculoskeletal Medicine, University of Leeds, Leeds, UK
| | - Paul Andrzejwski
- Academic Department of Trauma & Orthopaedics, School of Medicine, University of Leeds, Leeds, UK
| | - George Chloros
- Academic Department of Trauma & Orthopaedics, School of Medicine, University of Leeds, Leeds, UK
| | - Elizabeth M A Hensor
- Leeds Institute of Rheumatic and Musculoskeletal Medicine, University of Leeds, Leeds, UK
| |
Collapse
|
2
|
Evans S. Sacroiliac Joint Dysfunction in Endurance Runners Using Wearable Technology as a Clinical Monitoring Tool: Systematic Review. JMIR BIOMEDICAL ENGINEERING 2024; 9:e46067. [PMID: 38875697 PMCID: PMC11148519 DOI: 10.2196/46067] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/28/2023] [Revised: 10/02/2023] [Accepted: 10/30/2023] [Indexed: 06/16/2024] Open
Abstract
BACKGROUND In recent years, researchers have delved into the relationship between the anatomy and biomechanics of sacroiliac joint (SIJ) pain and dysfunction in endurance runners to elucidate the connection between lower back pain and the SIJ. However, the majority of SIJ pain and dysfunction cases are diagnosed and managed through a traditional athlete-clinician arrangement, where the athlete must attend regular in-person clinical appointments with various allied health professionals. Wearable sensors (wearables) are increasingly serving as a clinical diagnostic tool to monitor an athlete's day-to-day activities remotely, thus eliminating the necessity for in-person appointments. Nevertheless, the extent to which wearables are used in a remote setting to manage SIJ dysfunction in endurance runners remains uncertain. OBJECTIVE This study aims to conduct a systematic review of the literature to enhance our understanding regarding the use of wearables in both in-person and remote settings for biomechanical-based rehabilitation in SIJ dysfunction among endurance runners. In addressing this issue, the overarching goal was to explore how wearables can contribute to the clinical diagnosis (before, during, and after) of SIJ dysfunction. METHODS Three online databases, including PubMed, Scopus, and Google Scholar, were searched using various combinations of keywords. Initially, a total of 4097 articles were identified. After removing duplicates and screening articles based on inclusion and exclusion criteria, 45 articles were analyzed. Subsequently, 21 articles were included in this study. The quality of the investigation was assessed using the PRISMA (Preferred Reporting Items for Systematic Reviews and Meta-Analyses) evidence-based minimum set of items for reporting in systematic reviews. RESULTS Among the 21 studies included in this review, more than half of the investigations were literature reviews focusing on wearable sensors in the diagnosis and treatment of SIJ pain, wearable movement sensors for rehabilitation, or a combination of both for SIJ gait analysis in an intelligent health care setting. As many as 4 (19%) studies were case reports, and only 1 study could be classified as fully experimental. One paper was classified as being at the "pre" stage of SIJ dysfunction, while 6 (29%) were identified as being at the "at" stage of classification. Significantly fewer studies attempted to capture or classify actual SIJ injuries, and no study directly addressed the injury recovery stage. CONCLUSIONS SIJ dysfunction remains underdiagnosed and undertreated in endurance runners. Moreover, there is a lack of clear diagnostic or treatment pathways using wearables remotely, despite the availability of validated technology. Further research of higher quality is recommended to investigate SIJ dysfunction in endurance runners and explore the use of wearables for rehabilitation in remote settings.
Collapse
Affiliation(s)
- Stuart Evans
- School of Education, La Trobe University, Melbourne, Australia
| |
Collapse
|
3
|
Lebert L, Keppler AM, Bruder J, Faust L, Becker CA, Böcker W, Neuerburg C, Cavalcanti Kußmaul A. Evaluation of a New Treatment Strategy for Geriatric Fragility Fractures of the Posterior Pelvic Ring Using Sensor-Supported Insoles: A Proof-of-Concept Study. J Clin Med 2023; 12:5199. [PMID: 37629241 PMCID: PMC10455983 DOI: 10.3390/jcm12165199] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/10/2023] [Revised: 08/03/2023] [Accepted: 08/08/2023] [Indexed: 08/27/2023] Open
Abstract
The incidence of fragility fractures of the pelvis (FFPs) is currently rising. Surgical treatment, which is performed using sacroiliac screws, is complicated by compromised bone quality, oftentimes resulting in implant failure. The iFuse implant system aims to improve attachment and durability with promising results for sacroiliac dysfunction, though data for its feasibility on FFPs are rare. Consequently, this study aims to evaluate the feasibility of the iFuse for FFPs. A total of 10 patients with FFPs were treated with the iFuse in this study. Pre- and postoperatively, both mobility using an established insole force sensor for an inpatient gait analysis and general well-being and pain using questionnaires were evaluated. When comparing pre- and postoperative findings, this study demonstrated a significant increase in the average (8.14%) and maximum (9.4%) loading (p < 0.001), a reduction in pain, as measured by the visual analog scale (VAS), from 4.60 to 2.80 at rest (p = 0.011) and from 7.00 to 4.40 during movement (p = 0.008), an increase in the Barthel Index by 20 points (p < 0.001) and an increase in the Parker Mobility Score by 2.00 points (p = 0.011). All this contributes to the possibility of early postoperative mobilization and improved general well-being, ultimately preventing the late consequences of postoperative immobilization and maintaining patients autonomy and contentment.
Collapse
Affiliation(s)
| | | | | | | | | | | | | | - Adrian Cavalcanti Kußmaul
- Department of Orthopaedics and Trauma Surgery, Musculoskeletal University Center Munich (MUM), LMU University Hospital, LMU Munich, Marchioninistraße 15, 81377 Munich, Germany
| |
Collapse
|
4
|
Filimonova GN, Diuriagina OV, Antonov NI, Stogov MV, Ryabykh SO, Tushina NV. Characteristics of <i>m. Psoas minor</i> and <i>m. Sacrocaudalis (coccygeus)</i> dorsalis lateralis in simultaneous modeling of lateral interbodial spinnylodesis and posterior sacro-iliac joint arthodesis. N.N. PRIOROV JOURNAL OF TRAUMATOLOGY AND ORTHOPEDICS 2023; 29:379-390. [DOI: 10.17816/vto253610] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 09/03/2023]
Abstract
BACKGROUND: Simultaneous surgical interventions on the spine with the use of high-tech instruments and minimally invasive access techniques allow to eliminate several problems all at once, to activate patients at an early date and to reduce the number of complications. AIM: To evaluate morphological changes to evaluate morphological changes in the m. Psoas minor and m. Sacrocaudalis dorsalis lateralis during simultaneous modeling of lateral interbody fusion and posterior sacroiliac joint arthrodesis MATERIALS AND METHODS: Experiments were carried out on 14 outbred dogs; 3 animals formed a control group. The animals underwent consecutive lateral interbody fusion of the lumbar spine and posterior arthrodesis of the sacroiliac joint. The lumbar spine and sacroiliac joint were stabilized with external fixation device. Paraffin sections of muscles were stained with hematoxylin-eosin, according to Van Gieson, and Masson. Biochemical analysis of blood serum was performed during the experiment. RESULTS: The morphological study of the muscles revealed pathohistological features such as an increase in the variety of myosymplast diameters, loss of their profiles polygonality, massive fibers fatty degeneration, endo- and perimysial fibrosis, sclerotization of vessel membranes, obliteration of their lumens. At the end of the experiment, the degree of the small lumbar muscle fibrosis was 161% and of the sacrocaudal dorsal lateral muscle fibrosis was 240% of the control parameters (p 0.05); the rate of the muscle fatty infiltration was 339 and 310% of the normal value, respectively. The sacroiliac-caudal dorsal lateral muscle underwent more marked changes, especially in the early stages of the experiment. A significant increase in the enzymes activity, skeletal muscle damage markers was detected on the 14th day after surgery. CONCLUSION: Simultaneous surgical interventions on the spine should minimize mechanical effects on the paravertebral muscles and use techniques to stimulate their function in the postoperative period, which will reduce the processes of fibrogenesis and fat involution as well as provide an overall shorter rehabilitation period for the target patients.
Collapse
|
5
|
Beyond the pedicle screw-a patent review. EUROPEAN SPINE JOURNAL : OFFICIAL PUBLICATION OF THE EUROPEAN SPINE SOCIETY, THE EUROPEAN SPINAL DEFORMITY SOCIETY, AND THE EUROPEAN SECTION OF THE CERVICAL SPINE RESEARCH SOCIETY 2022; 31:1553-1565. [PMID: 35380271 DOI: 10.1007/s00586-022-07193-z] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/04/2022] [Revised: 03/17/2022] [Accepted: 03/18/2022] [Indexed: 10/18/2022]
Abstract
PURPOSE This review provides an overview of the patent literature on posteriorly placed intrapedicular bone anchors. Conventional pedicle screws are the gold standard to create a fixation in the vertebra for spinal fusion surgery but may lack fixation strength, especially in osteoporotic bone. The ageing population demands new bone anchors that have an increased fixation strength, that can be placed safely, and, if necessary, can be removed without damaging the surrounding tissue. METHODS The patent search was conducted using a classification search in the Espacenet patent database. Only patents with a Cooperative Patent Classification of A61B17/70 or A61B17/7001 concerning spinal positioners and stabilizers were eligible for inclusion. The search query resulted in the identification of 731 patents. Based on preset inclusion criteria, a total of 56 unique patents on different anchoring methods were included, reviewed and categorized in this study. RESULTS Five unique fixation methods were identified; (1) anchors that use threading, (2) anchors that utilize a curved path through the vertebra, (3) anchors that (partly) expand, (4) anchors that use cement and (5) anchors that are designed to initiate bone ingrowth. Of the anchor designs included in this study, eight had a corresponding commercial product, six of which were evaluated in clinical trials. CONCLUSION This review provides insights into worldwide patented intrapedicular bone anchors that aim to increase the fixation strength compared to the conventional pedicle screw. The identified anchoring methods and their working principles can be used for clinical decision-making and as a source of inspiration when designing novel bone anchors.
Collapse
|
6
|
Beijk I, Knoef R, van Vugt A, Verra W, Nellensteijn J. Sacroiliac joint fusion in patients with Ehlers Danlos Syndrome: A case series. NORTH AMERICAN SPINE SOCIETY JOURNAL (NASSJ) 2021; 8:100082. [PMID: 35141647 PMCID: PMC8819966 DOI: 10.1016/j.xnsj.2021.100082] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 06/15/2021] [Revised: 09/20/2021] [Accepted: 09/20/2021] [Indexed: 11/04/2022]
Abstract
Background Sacroiliac joint dysfunction (SJD) is a known cause of lower back pain. SJD might be due to hypermobility in the Sacroiliac joint (SIJ) in patients with Ehlers Danlos Syndrome (EDS). Stabilization of the SIJ can be a highly successful treatment for lower back pain. No previous literature about EDS and SIJ fusion is available. The purpose of this study was to assess our mid-term results of SIJ fusion surgery in EDS patients suffering from SIJ dysfunction. Methods A case series of patients who underwent SIJ fusion for SIJ dysfunction due to EDS between January 2012 and December 2018 were analyzed in retrospect. Patients underwent surgery and the SIJ was stabilized with triangular implants bridging the joint. Pain and functional outcomes were assessed in nine agree/disagree questions and a satisfaction performance scale. Clinical data has been extracted from the patient files and in addition, we reassessed the position of the implants on the CT scans. Results A total of 16 patients with EDS completed the questionnaire and were available for analysis. The mean satisfaction score is 78.1 out of 100 and seven patients reported a 100% satisfaction score. Conclusion SIJ fusion is a safe and useful procedure to reduce pain and function levels in EDS patients with lower back pain due to SIJ dysfunction.
Collapse
|
7
|
[Minimally invasive arthrodesis of the sacroiliac joint (SIJ)]. OPERATIVE ORTHOPADIE UND TRAUMATOLOGIE 2021; 34:98-108. [PMID: 34661704 DOI: 10.1007/s00064-021-00738-3] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/03/2020] [Revised: 09/15/2020] [Accepted: 09/25/2020] [Indexed: 10/20/2022]
Abstract
OBJECTIVE Pain reduction and improvement in quality of life with sacroiliac joint (SIJ) fusion. INDICATIONS Chronic SIJ-associated pain; positive response to SIJ injection with local anesthetic; positive SIJ provocation tests; failed conservative therapy over 6 months. CONTRAINDICATIONS Non-SIJ-associated pain; tumor/infection/unstable fracture in the implantation area; malformations; tumor or osteolysis of the sacrum or ilium bone; active infection at the implantation site; allergy to metal components; secondary gain from illness, request for a pension; inadequately treated osteoporosis. SURGICAL TECHNIQUE Transarticular placement of Kirschner's wires through the SI joint via minimally invasive lateral approach. Guided preparation of implant site over Kirschner's wires and implantation of 3 triangular, transarticular titanium implants for SIJ fusion. POSTOPERATIVE MANAGEMENT Deep vein thrombosis prophylaxis. 3 weeks partial weight-bearing and then moving on to full weight-bearing. X‑ray controls at defined intervals. Physiotherapy. RESULTS We enrolled 26 patients who were followed up over the period of 4 years. The evaluated endpoints were low back pain on the visual analog scale (VAS 0-10), grade of disability with the Oswestry Disability Index (ODI) and quality of life with the EuroQOL-5D. At 4 years, mean low back pain improved compared to preoperative (VAS preoperative 8.4, VAS 4 years postoperative 4.6). Mean improvements in ODI (ODI preoperative 58.1, ODI 4 years postoperative 32.1) and EQ-5D (preoperative 0.5, after 4 years 0.7) could be evaluated over the long-term period of 4 years. Satisfaction rates were high and the proportion of subjects taking opioids decreased at the 4‑year follow-up (preoperative 82%, postoperative 39%). Implant loosening could not be detected on plain radiograph.
Collapse
|
8
|
Novel Interventional Techniques for Chronic Pain with Minimally Invasive Arthrodesis of the Sacroiliac Joint: (INSITE, iFuse, Tricor, Rialto, and others). Rheumatol Ther 2021; 8:1061-1072. [PMID: 34331270 PMCID: PMC8380604 DOI: 10.1007/s40744-021-00350-8] [Citation(s) in RCA: 9] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/11/2021] [Accepted: 07/09/2021] [Indexed: 12/18/2022] Open
Abstract
Acute and chronic pain are public health issues that clinicians have been battling for years. Opioid medications have been a treatment option for both chronic and acute pain; however, they can cause unwanted complications and are a major contributor to our present opioid epidemic. The sacroiliac (SI) joint is a common cause of both acute and chronic low back pain. It affects about 15–25% of patients with axial low back pain, and up to 40% of patients with ongoing pain following lumbar fusion. Recent advances in the treatment of SI joint pain have led to the development of a wide variety of SI joint fusion devices. These fusion devices seek to stabilize the joints themselves in order that they become immobile and, in theory, can no longer be a source for pain. This is a minimally invasive procedure aimed to address chronic pain without subjecting patients to lengthy surgery or medications, including opioids with the potential for addiction and abuse. Minimally invasive SI fusion can be performed by a lateral approach (i.e., iFuse, Tricor) or posterior approach (i.e., CornerLoc, LinQ, Rialto). The posterior approach requires the patient to be in the prone position but allows for less disruption of muscles with entry. More data are necessary to determine which fusion system may be best for a particular patient. SI fusion devices are a promising way of treating chronic lower back pain related to the SI joint. This narrative review will discuss various types of SI fusion devices, and their potential use in terms of their safety and efficacy.
Collapse
|
9
|
Blissett DB, Blissett RS, Ede MPN, Stott PM, Cher DJ, Reckling WC. Minimally Invasive Sacroiliac Joint Fusion with Triangular Titanium Implants: Cost-Utility Analysis from NHS Perspective. PHARMACOECONOMICS - OPEN 2021; 5:197-209. [PMID: 33165824 PMCID: PMC8160075 DOI: 10.1007/s41669-020-00236-5] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Accepted: 10/15/2020] [Indexed: 06/09/2023]
Abstract
OBJECTIVE The aim was to identify the cost-effectiveness of minimally invasive sacroiliac joint fusion (MI SIJF) surgery with titanium triangular implants for patients with sacroiliac joint (SIJ) pain who have failed conservative management, compared to non-surgical management (NSM) from a National Health Service (NHS) England perspective. METHODS Over a time horizon of 5 years, a cohort state transition model compared the costs and outcomes of treating patients with MI SIJF to those of traditional NSM treatment pathways. The NSM arm included two treatments: grouped physical therapy and corticosteroid injections (PTSI) or radiofrequency ablation (RFA). Three different strategies were considered: (1) a stepped pathway, (2) patients split between PTSI and RFA, and (3) RFA only. The outcome measure was incremental cost-effectiveness ratio (ICER), reported in 2018 British pounds per quality-adjusted life year (QALY) gained. One-way and probabilistic sensitivity analyses were used to test the robustness of the model results. RESULTS Patients undergoing MI SIJF accrued total procedure-related and pain-management costs of £8358, while NSM treatment strategy 1 had total costs of £6880. The MI SIJF cohort had 2.98 QALYs compared to strategy 1 with 2.30 QALYs. This resulted in an ICER for MI SIJF versus strategy 1 of £2164/QALY gained. Strategy 2 of the NSM arm had lower costs than strategy 1 (£6564) and 2.26 QALYs, and this resulted in an ICER of £2468/QALY gained for MI SIJF. Strategy 3 of the NSM arm had lower costs than strategy 1 (£6580), and this resulted in 2.28 QALYs and an ICER of £2518/QALY gained for MI SIJF. Probabilistic sensitivity analysis shows that at a threshold of £20,000/QALY gained, MI SIJF has a probability of being cost-effective versus NSM strategies of 96%, 97%, and 91% for strategies 1, 2, and 3, respectively. CONCLUSION MI SIJF appears to be cost-effective over a 5-year time horizon when compared to traditional NSM pathways in an NHS context.
Collapse
Affiliation(s)
| | | | - Matthew P Newton Ede
- The Royal Orthopaedic Hospital, Bristol Road South, Birmingham, UK
- Precision Spine, 81 Harborne Road, Edgbaston, Birmingham, UK
| | - Philip M Stott
- Brighton and Sussex University Hospitals NHS Trust, Eastern Road, Brighton, UK
| | - Daniel J Cher
- Department of Clinical Affairs, SI-BONE, Inc., San Jose, CA, USA
| | | |
Collapse
|
10
|
Ali A, Andrzejowski P, Kanakaris NK, Giannoudis PV. Pelvic Girdle Pain, Hypermobility Spectrum Disorder and Hypermobility-Type Ehlers-Danlos Syndrome: A Narrative Literature Review. J Clin Med 2020; 9:jcm9123992. [PMID: 33317183 PMCID: PMC7764306 DOI: 10.3390/jcm9123992] [Citation(s) in RCA: 12] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/23/2020] [Revised: 11/27/2020] [Accepted: 12/04/2020] [Indexed: 01/04/2023] Open
Abstract
Pelvic girdle pain (PGP) refers specifically to musculoskeletal pain localised to the pelvic ring and can be present at its anterior and/or posterior aspects. Causes such as trauma, infection and pregnancy have been well-established, while patients with hypermobile joints are at greater risk of developing PGP. Research exploring this association is limited and of varying quality. In the present study we report on the incidence, pathophysiology, diagnostic and treatment modalities for PGP in patients suffering from Hypermobility Spectrum Disorder (HSD) and Hypermobility-Type Ehlers-Danlos Syndrome (hEDS). Recommendations are made for clinical practice by elaborating on screening, diagnosis and management of such patients to provide a holistic approach to their care. It appears that this cohort of patients are at greater risk particularly of mental health issues. Moreover over, they may require a multidisciplinary approach for their management. Ongoing research is still required to expand our understanding of the relationship between PGP, HSD and hEDS by appropriately diagnosing patients using the latest updated terminologies and by conducting randomised control trials to compare outcomes of interventions using standardised patient reported outcome measures.
Collapse
Affiliation(s)
- Ahmed Ali
- Academic Department of Trauma and Orthopaedics, School of Medicine, University of Leeds, Floor D, Clarendon Wing, Leeds General Infirmary, Great George Street, Leeds LS1 3EX, UK
| | - Paul Andrzejowski
- Academic Department of Trauma and Orthopaedics, School of Medicine, University of Leeds, Floor D, Clarendon Wing, Leeds General Infirmary, Great George Street, Leeds LS1 3EX, UK
| | - Nikolaos K Kanakaris
- Academic Department of Trauma and Orthopaedics, School of Medicine, University of Leeds, Floor D, Clarendon Wing, Leeds General Infirmary, Great George Street, Leeds LS1 3EX, UK
| | - Peter V Giannoudis
- Academic Department of Trauma and Orthopaedics, School of Medicine, University of Leeds, Floor D, Clarendon Wing, Leeds General Infirmary, Great George Street, Leeds LS1 3EX, UK
- NIHR Leeds Biomedical Research Unit, Chapel Allerton Hospital, Leeds LS7 4SA, UK
| |
Collapse
|