3
|
YAMADA Y, HAYASHI T, SAKURABA H, YABUTANI T, TAKAYANAGI T. Fabrication and Characterization of a Thermostable Quinoprotein Aldose Sugar Dehydrogenase Immobilized Electrode. ANAL SCI 2013; 29:79-83. [DOI: 10.2116/analsci.29.79] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
Affiliation(s)
- Yohei YAMADA
- Department of Chemical Science and Technology, Institute of Science and Technology, The University of Tokushima
| | - Tetsuya HAYASHI
- Department of Chemical Science and Technology, Institute of Science and Technology, The University of Tokushima
| | - Haruhiko SAKURABA
- Department of Applied Biological Science, Faculty of Agriculture, Kagawa University
| | - Tomoki YABUTANI
- Department of Chemical Science and Technology, Institute of Science and Technology, The University of Tokushima
| | - Toshio TAKAYANAGI
- Department of Chemical Science and Technology, Institute of Science and Technology, The University of Tokushima
| |
Collapse
|
10
|
Ikeda T, Kano K. Bioelectrocatalysis-based application of quinoproteins and quinoprotein-containing bacterial cells in biosensors and biofuel cells. BIOCHIMICA ET BIOPHYSICA ACTA 2003; 1647:121-6. [PMID: 12686120 DOI: 10.1016/s1570-9639(03)00075-x] [Citation(s) in RCA: 83] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 10/27/2022]
Abstract
Electrochemical studies on the applied aspects of quinoproteins are briefly reviewed. Catalytic reactions of quinoprotein enzymes can be connected to electrochemical reactions directly or by the mediation of molecules functioning as electron acceptors of the enzymes. Such an enzyme-electrochemical reaction is called bioelectrocatalysis. It provides a novel method of kinetic analysis of enzyme catalysis and even whole bacterial cell catalysis. The principle of bioelectrocatalysis is first described, then, the bioelectrocatalysis-based application of quinoproteins in biosensors is mentioned. Characteristics and performance of this type of biosensor is explained by citing our own work. Possible application in bioreactors and biofuel cells is also mentioned.
Collapse
Affiliation(s)
- Tokuji Ikeda
- Division of Applied Life Sciences, Graduate School of Agriculture, Kyoto University, Sakyo, Kyoto 606 8502, Japan.
| | | |
Collapse
|
15
|
Tessema M, Csöregi E, Ruzgas T, Kenausis G, Solomon T, Gorton L. Oligosaccharide Dehydrogenase-Modified Graphite Electrodes for the Amperometric Determination of Sugars in a Flow Injection System. Anal Chem 1997; 69:4039-44. [DOI: 10.1021/ac970127f] [Citation(s) in RCA: 22] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
Affiliation(s)
- Merid Tessema
- Department of Chemistry, Addis Ababa University, P.O. Box 1176, Addis Ababa, Ethiopia, Department of Analytical Chemistry, University of Lund, P.O. Box 124, SE-221 00, Lund, Sweden, Enzyme Chemistry Laboratory, Institute of Biochemistry, Mokslininku 12, LT-2600 Vilnius, Lithuania, and Department of Chemical Engineering, The University of Texas at Austin, Austin, Texas 78712-1062
| | - Elisabeth Csöregi
- Department of Chemistry, Addis Ababa University, P.O. Box 1176, Addis Ababa, Ethiopia, Department of Analytical Chemistry, University of Lund, P.O. Box 124, SE-221 00, Lund, Sweden, Enzyme Chemistry Laboratory, Institute of Biochemistry, Mokslininku 12, LT-2600 Vilnius, Lithuania, and Department of Chemical Engineering, The University of Texas at Austin, Austin, Texas 78712-1062
| | - Tautgirdas Ruzgas
- Department of Chemistry, Addis Ababa University, P.O. Box 1176, Addis Ababa, Ethiopia, Department of Analytical Chemistry, University of Lund, P.O. Box 124, SE-221 00, Lund, Sweden, Enzyme Chemistry Laboratory, Institute of Biochemistry, Mokslininku 12, LT-2600 Vilnius, Lithuania, and Department of Chemical Engineering, The University of Texas at Austin, Austin, Texas 78712-1062
| | - Gregg Kenausis
- Department of Chemistry, Addis Ababa University, P.O. Box 1176, Addis Ababa, Ethiopia, Department of Analytical Chemistry, University of Lund, P.O. Box 124, SE-221 00, Lund, Sweden, Enzyme Chemistry Laboratory, Institute of Biochemistry, Mokslininku 12, LT-2600 Vilnius, Lithuania, and Department of Chemical Engineering, The University of Texas at Austin, Austin, Texas 78712-1062
| | - Theodros Solomon
- Department of Chemistry, Addis Ababa University, P.O. Box 1176, Addis Ababa, Ethiopia, Department of Analytical Chemistry, University of Lund, P.O. Box 124, SE-221 00, Lund, Sweden, Enzyme Chemistry Laboratory, Institute of Biochemistry, Mokslininku 12, LT-2600 Vilnius, Lithuania, and Department of Chemical Engineering, The University of Texas at Austin, Austin, Texas 78712-1062
| | - Lo Gorton
- Department of Chemistry, Addis Ababa University, P.O. Box 1176, Addis Ababa, Ethiopia, Department of Analytical Chemistry, University of Lund, P.O. Box 124, SE-221 00, Lund, Sweden, Enzyme Chemistry Laboratory, Institute of Biochemistry, Mokslininku 12, LT-2600 Vilnius, Lithuania, and Department of Chemical Engineering, The University of Texas at Austin, Austin, Texas 78712-1062
| |
Collapse
|
16
|
Švorc J, Miertuš S, Katrlík J, Stred'anský M. Composite Transducers for Amperometric Biosensors. The Glucose Sensor. Anal Chem 1997; 69:2086-90. [DOI: 10.1021/ac9609485] [Citation(s) in RCA: 46] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Affiliation(s)
- Jozef Švorc
- Area di Ricerca, POLY-tech, Padriciano 99, 34012 Trieste, Italy, and Slovak Technical University, Radlinskeho 9, 812 37 Bratislava, Slovakia
| | - Stanislav Miertuš
- Area di Ricerca, POLY-tech, Padriciano 99, 34012 Trieste, Italy, and Slovak Technical University, Radlinskeho 9, 812 37 Bratislava, Slovakia
| | - Jaroslav Katrlík
- Area di Ricerca, POLY-tech, Padriciano 99, 34012 Trieste, Italy, and Slovak Technical University, Radlinskeho 9, 812 37 Bratislava, Slovakia
| | - Miroslav Stred'anský
- Area di Ricerca, POLY-tech, Padriciano 99, 34012 Trieste, Italy, and Slovak Technical University, Radlinskeho 9, 812 37 Bratislava, Slovakia
| |
Collapse
|