Gurney EP, Sonalkar S, McAllister A, Sammel MD, Schreiber CA. Six-month expulsion of postplacental copper intrauterine devices placed after vaginal delivery. Am J Obstet Gynecol 2018; 219:183.e1-183.e9. [PMID: 29870737 DOI: 10.1016/j.ajog.2018.05.032] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/22/2018] [Revised: 05/18/2018] [Accepted: 05/24/2018] [Indexed: 12/15/2022]
Abstract
BACKGROUND Immediate placement of an intrauterine device after vaginal delivery is safe and convenient, but longitudinal data describing clinical outcomes have been limited. OBJECTIVE We sought to determine the proportion of TCu380A (copper) intrauterine devices expelled, partially expelled, malpositioned, and retained, as well as contraceptive use by 6 months postpartum, and determine risk factors for expulsion and partial expulsion. STUDY DESIGN In this prospective, observational study, women who received a postplacental TCu380A intrauterine device at vaginal delivery were enrolled postpartum. Participants returned for clinical follow-up at 6 weeks, and for a research visit with a pelvic exam and ultrasound at 6 months. We recorded intrauterine device outcomes and 6-month contraceptive use. Partial expulsion was defined as an intrauterine device protruding from the external cervical os, or a transvaginal ultrasound showing the distal end of the intrauterine device below the internal os of the cervix. Multinomial logistic regression models identified risk factors associated with expulsion and partial expulsion by 6 months. The area under the receiver operating characteristics curve was used to assess the ability of a string check to predict the correct placement of a postplacental intrauterine device. The primary outcome was the proportion of intrauterine devices expelled at 6 months. RESULTS We enrolled 200 women. Of 162 participants with follow-up data at 6 months, 13 (8.0%; 95% confidence interval, 4.7-13.4%) experienced complete expulsion and 26 (16.0%; 95% confidence interval, 11.1-22.6%) partial expulsion. Of 25 malpositioned intrauterine devices (15.4%; 95% confidence interval, 10.2-21.9%), 14 were not at the fundus (8.6%; 95% confidence interval, 5.2-14.1%) and 11 were rotated within the uterus (6.8%; 95% confidence interval, 3.8-11.9%). Multinomial logistic regression modeling indicated that higher parity (odds ratio, 2.05; 95% confidence interval, 1.21-3.50; P = .008) was associated with expulsion. Provider specialty (obstetrics vs family medicine; odds ratio, 5.31; 95% confidence interval, 1.20-23.59; P = .03) and gestational weight gain (normal vs excess; odds ratio, 9.12; 95% confidence interval, 1.90-43.82; P = .004) were associated with partial expulsion. Long-acting reversible contraceptive method use at 6 months was 80.9% (95% confidence interval, 74.0-86.6%). At 6 weeks postpartum, 35 of 149 (23.5%; 95% confidence interval, 16.9-31.1%) participants had no intrauterine device strings visible. Sensitivity of a string check to detect an incorrectly positioned intrauterine device was 36.2%, and specificity of the string check to predict a correctly positioned intrauterine device was 84.5%. This corresponds to an area under the receiver operating characteristics curve of 0.5. CONCLUSION This prospective assessment of postplacental TCu380A intrauterine device placement, with ultrasound to confirm device position, finds a complete intrauterine device expulsion proportion of 8.0% at 6 months. The association of increasing parity with expulsion is consistent with prior research. The clinical significance of covariates associated with partial expulsion (provider specialty and gestational weight gain) is unclear. Due to the observational study design, any associations cannot imply causality. The proportion of partially expelled and malpositioned intrauterine devices was high, and the area under the receiver operating characteristics curve of 0.5 indicates that a string check is a poor test for assessing device position. Women considering a postplacental intrauterine device should be counseled about the risk of position abnormalities, as well as the possibility of nonvisible strings, which may complicate clinical follow-up. The clinical significance of intrauterine device position abnormalities is unknown; future research should evaluate the influence of malposition and partial expulsion on contraceptive effectiveness and side effects.
Collapse
|
2
|
Wildemeersch D, Andrade A, Goldstuck N. Femilis(®) 60 Levonorgestrel-Releasing Intrauterine System-A Review of 10 Years of Clinical Experience. CLINICAL MEDICINE INSIGHTS. REPRODUCTIVE HEALTH 2016; 10:19-27. [PMID: 27547046 PMCID: PMC4979586 DOI: 10.4137/cmrh.s40087] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 05/04/2016] [Revised: 06/09/2016] [Accepted: 06/11/2016] [Indexed: 11/29/2022]
Abstract
OBJECTIVE The aim of this study was to update the clinical experience with the Femilis® 60 levonorgestrel-releasing intrauterine system (LNG-IUS), now up to 10 years in parous and nulliparous women, particularly with regard to ease and safety of insertion, contraceptive performance, retention, acceptability, continuation of use, impact on menstrual blood loss (MBL), and duration of action. STUDY DESIGN Using the Femilis® 60 LNG-IUS releasing 20 µg of levonorgestrel/day, the following studies were conducted: an open, prospective noncomparative contraceptive study, an MBL study, a perimenopausal study, a study for the treatment of endometrial hyperplasia, and early cancer of the uterus, a residue study. RESULTS A total of 599 Femilis LNG-IUS were inserted in various clinical trials, the majority for contraceptive purposes. The total exposure in the first and second contraceptive studies, covering 558 parous and nulliparous women, was 32,717 woman-months. Femilis has high contraceptive effectiveness as only one pregnancy occurred. Expulsion of the LNG-IUS was rare with only two total and no partial expulsions (stem protruding through the cervical canal) occurred. Femilis was well tolerated, with continuation rates remaining high. Several MBL studies were conducted, totaling 80 heavy and normal menstrual bleeders, using the pictorial bleeding assessment chart method or the quantitative alkaline hematin technique. Virtually all women responded well with strongly reduced menstrual bleeding. Amenorrhea rates were high, up to 80% after three months, and ferritin levels simultaneously increased significantly. The Femilis LNG-IUS was tested in 104 symptomatic perimenopausal women for seamless transition to and through menopause, adding estrogen therapy when required. Patient tolerability appeared high as >80% requested a second and a third LNG-IUS. Twenty women presenting with nonatypical and atypical hyperplasia and one woman presenting with early endometrial carcinoma were treated with Femilis LNG-IUS. All histology specimens showed full regression, and patients remained in remission without signs of hyperplasia or cancer at yearly and ongoing follow-up examinations up to 10 years. Residual content of LNG was measured in 37 women having the Femilis LNG-IUS for up to 10 years. In 10 of the 102 women who had the Femilis 60 in situ for 10 years between 20% and 30% of the original 60 mg was recovered confirming the long duration of action of the Femilis 60 LNG-IUS. CONCLUSION These studies suggest that the Femilis 60 LNG-IUS releasing 20 µg of LNG/day is an effective, well-tolerated, and well-retained contraceptive both in parous and in nulliparous women. The design of the LNG-IUS, with flexible transverse arm(s) length of 28 mm, allows for a simplification of the insertion technique and training requirements facilitating the use by nonspecialist providers in either developed or developing countries. For nulliparous women, additional evaluation of devices with a 24 mm transverse arm(s), as it relates to tolerability, retention, and continuation of use, still needs to be undertaken.
Collapse
Affiliation(s)
- Dirk Wildemeersch
- Gynecological Outpatient Clinic and IUD Training Center, Ghent, Belgium
| | - Amaury Andrade
- Center for Reproductive Biology, Federal University Juiz de Fora, Juiz de Fora, Brazil
| | - Norman Goldstuck
- Department of Obstetrics and Gynaecology, Faculty of Medicine and Health Sciences, Stellenbosch University and Tygerberg Hospital, Western Cape, South Africa
| |
Collapse
|
3
|
Wildemeersch D, Pett A, Jandi S, Hasskamp T, Rowe P, Vrijens M. Precision intrauterine contraception may significantly increase continuation of use: a review of long-term clinical experience with frameless copper-releasing intrauterine contraception devices. Int J Womens Health 2013; 5:215-25. [PMID: 23658502 PMCID: PMC3645905 DOI: 10.2147/ijwh.s42784] [Citation(s) in RCA: 27] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/24/2022] Open
Abstract
Objective The purpose of this paper is to review the experience with the frameless, anchored, GyneFix copper-releasing intrauterine contraceptive devices (IUCDs/IUDs) (Contrel Europe, Belgium), and to demonstrate their high acceptability and low rate of discontinuation of use, which could contribute to current efforts that aim to reduce radically the high number of unintended pregnancies and induced abortions, particularly in young women. Materials and methods This paper is based on studies that examined the differences in uterine volume and cavity size, related to age and parity, and on original clinical research data and practical experience with frameless copper IUDs, as well as on literature data on the IUD–endometrial cavity relationship of conventional IUDs, with special reference to side effects and user discontinuation. Results The mean transverse diameter in nulliparous and parous women is significantly less than the length of the transverse arm of the TCu380A IUD (ParaGard, Duramed, NY, USA) or the levonorgestrel intrauterine system (Mirena, Bayer, Germany). Small, frameless, flexible, and unidimensional copper IUDs appear to be well tolerated, with less impact on menstrual bleeding, resulting in low discontinuation rates when compared with standard-size conventional IUDs, which often result in increased expulsion rates, complaints of pain and erratic or increased menstrual bleeding, and subsequent high rates of discontinuation, particularly in young women. Conclusion The unidimensional GyneFix IUDs fit the majority of uterine cavities. An IUD that fits is likely to result in increased tolerance and continued use of the method. As this would appeal to women, the logical result should be greater use of the method and fewer unintended pregnancies and induced abortions. Recommending the standard TCu380A (ParaGard) IUD or the Mirena levonorgestrel intrauterine system, primarily developed for use in parous women, for general use in nulliparous and adolescent women should be done with caution in the light of current scientific evidence, except if 3-D sonography indicates that the uterine cavity is sufficiently large.
Collapse
Affiliation(s)
- Dirk Wildemeersch
- Gynecological Outpatient Clinic and IUD Training Center, Ghent, Belgium
| | | | | | | | | | | |
Collapse
|
4
|
Mansour D, Inki P, Gemzell-Danielsson K. Efficacy of contraceptive methods: A review of the literature. EUR J CONTRACEP REPR 2010; 15:4-16. [DOI: 10.3109/13625180903427675] [Citation(s) in RCA: 90] [Impact Index Per Article: 6.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/13/2022]
|
5
|
|
6
|
Copper-containing, framed intrauterine devices for contraception: a systematic review of randomized controlled trials. Contraception 2008; 77:318-27. [DOI: 10.1016/j.contraception.2007.12.011] [Citation(s) in RCA: 58] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/30/2007] [Revised: 12/21/2007] [Accepted: 12/21/2007] [Indexed: 11/22/2022]
|
7
|
Thonneau PF, Almont T. Contraceptive efficacy of intrauterine devices. Am J Obstet Gynecol 2008; 198:248-53. [PMID: 18221924 DOI: 10.1016/j.ajog.2007.10.787] [Citation(s) in RCA: 54] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/07/2007] [Revised: 10/01/2007] [Accepted: 10/01/2007] [Indexed: 11/17/2022]
Abstract
To compare the contraceptive efficacy of various types of intrauterine devices (IUD; copper devices, Nova-T, intrauterine contraceptive systems, levonorgestrel-releasing devices), we reviewed all relevant publications on this subject that have been published over the last 2 decades. The first point to be highlighted by this review is the excellent effectiveness of IUDs, with a global cumulative pregnancy rate <2% at 5 years, whatever the type of device used. We observed a large variation in efficacy rate according to the type of IUD and also according to study design. Nevertheless, of all the types of IUDs, the levonorgestrel-releasing IUD and to a lesser extent the TCu380A IUD seem to be the most effective, with a cumulative pregnancy rate at 5 years of <0.5% for the levonorgestrel-releasing IUD and between 0.3% and 0.6% for the TCu380A IUD.
Collapse
|
8
|
Kulier R, O'Brien PA, Helmerhorst FM, Usher-Patel M, D'Arcangues C. Copper containing, framed intra-uterine devices for contraception. Cochrane Database Syst Rev 2007:CD005347. [PMID: 17943851 DOI: 10.1002/14651858.cd005347.pub3] [Citation(s) in RCA: 36] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
Abstract
BACKGROUND Intrauterine devices (IUD) are safe and effective methods of long term reversible contraception. The design, and copper content as well as placement of the copper on IUDs could affect their effectiveness and side-effect profile. OBJECTIVES We compared different copper IUDs for their effectiveness and side effects. SEARCH STRATEGY Multiple electronic databases were searched with appropriate key words and names of the IUDs known to be in the market. We searched the reference lists of papers identified and contacted trialists when possible. There was no language restriction. SELECTION CRITERIA Randomised controlled trials comparing different IUDs were considered. Trials needed to report on clinical outcomes. DATA COLLECTION AND ANALYSIS Data on outcomes and trial characteristics were extracted in duplicate and independently by two reviewers. Meta-analysis results are expressed as rate difference (RD) using a fixed-effects model with 95% confidence interval (CI). In the presence of significant heterogeneity a random-effects model was applied. MAIN RESULTS We included 35 trials, resulting in 18 comparisons of 10 different IUDs in approximately 48,000 women. TCu380A was more effective in preventing pregnancy than MLCu375 (RD 1.70%, 95% CI 0.07% to 2.95% after 4 years of use). TCu380A was also more effective than MLCu250, TCu220 and TCu200. There tended to be fewer pregnancies with TCu380S compared to TCu380A after the first year of use, a difference which was statistically significant in the fourth year (RD -1.62%, 95% CI -3.00% to -0.24%). This occurred despite more expulsions with TCu380S (RD 3.50%, 95% CI 0.36% to 6.63% at 4 years). MLCu375 was no more effective than TCu220 at 1 year of use, or MLCu250 and NovaT up to 3 years. Compared to TCu380A or TCu380S, none of the IUDs showed any benefits in terms of bleeding or pain, or any of the other reasons for early discontinuation. None of the trials that reported events at insertion found one IUD easier to insert than another or caused less pain at insertion. There is no evidence that uterine perforation rates vary by type of device. There are minimal randomised data on IUD use in nulliparous women. AUTHORS' CONCLUSIONS TCu380A or TCu380S appear to be more effective than other IUDs. No IUD showed consistently lower removal rates for bleeding and pain in comparison to other IUDs. There is no evidence that any particular framed copper device is better suited to women who have not had children.
Collapse
Affiliation(s)
- R Kulier
- Geneva Foundation for Medical Education and Research, Route de Florissant 3, Geneva, Switzerland, CH-1208,
| | | | | | | | | |
Collapse
|
9
|
Kulier R, Helmerhorst FM, O'Brien P, Usher-Patel M, d'Arcangues C. Copper containing, framed intra-uterine devices for contraception. Cochrane Database Syst Rev 2006:CD005347. [PMID: 16856094 DOI: 10.1002/14651858.cd005347.pub2] [Citation(s) in RCA: 13] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
Abstract
BACKGROUND Intrauterine devices (IUD) are safe and effective methods of long term reversible contraception. Design and copper content of IUDs could affect their effectiveness and side-effect profile. OBJECTIVES We compared different copper IUDs for their effectiveness and side effects. SEARCH STRATEGY Multiple electronic databases were searched with appropriate key words and names of the IUDs known to be in the market. We searched the reference lists of papers identified and contacted trialists when possible. SELECTION CRITERIA Randomised controlled trials comparing different IUDs were considered. Trials needed to report on clinical outcomes. DATA COLLECTION AND ANALYSIS Data on outcomes and trial characteristics were extracted in duplicate and independently by two reviewers. Meta-analysis results are expressed as rate difference (RD) using a fixed-effects model with 95% confidence interval (CI). In the presence of significant heterogeneity a random-effects model was applied. MAIN RESULTS We included 34 trials, resulting in 16 comparisons of different IUDs. TCu380A was more effective than MLCu375, MLCu250, TCu220 and TCu200. Changing the position of the copper on the arm of the IUD for TCu380S did not improve the efficacy of TCu380A. MLCu375 was no more effective than TCu220, at 1 year, MLCu250 to 3 years or NovaT to 3 years Compared to TCu380A, none of the IUDs showed any benefits in terms of bleeding or pain, or any of the other reasons for early discontinuation. AUTHORS' CONCLUSIONS TCu380A is more effective compared to other IUDs. There is no data available comparing different IUDs in special subgroups, such as nulliparous women.
Collapse
Affiliation(s)
- R Kulier
- Geneva Foundation for Medical Education and Research, Route de Florissant 3, Geneva, Switzerland CH-1208.
| | | | | | | | | |
Collapse
|
10
|
Abstract
BACKGROUND The frameless intrauterine device (IUD) dispenses with the frame in the classical IUD and holds the device in the uterus by anchoring one end of a nylon thread in the fundal myometrium, to which copper sleeves are attached. OBJECTIVES This review examines the hypothesis that the frameless IUD Gynefix reduces risk of expulsion and pregnancy, and the problems of bleeding and pain necessitating early removal. SEARCH STRATEGY We searched the Cochrane Controlled Trial Register (Cochrane Library Issue 2, 2004), MEDLINE, and Popline from 1980 to March 2004, and reference list of articles. SELECTION CRITERIA We selected for the review randomised trials that compared the frameless device to a classical framed device for contraception. DATA COLLECTION AND ANALYSIS Both authors extracted data independently. We contacted study author for additional data. We calculated rate ratios and rate differences for cumulative rates for each outcome at yearly intervals. We used the inverse variance-based method to combine trials, and tested the results for heterogeneity. MAIN RESULTS Four trials were included in the review involving 5,939 women randomised to either a frameless device or TCu380, with data up to eight years for the largest, and with a total experience of 23,180 years. Apart from one small trial, nulliparous women were excluded from the trials. The two earlier trials used a prototype introducer and there was a higher expulsion rate at one year (relative risk 2.48, 95% confidence intervals 1.89 to 3.26). However, between two and six years in the large WHO trial the risk of pregnancy was lower with the frameless device (relative risk 0.53, 95% confidence intervals 0.32 to 0.91). In a recent trial using GyneFix with a new introducer early expulsions and pregnancies were not statistically different from the control device. Removals rates for excessive bleeding and/or pain were no different between the devices (relative risks 0.92, 95% confidence intervals 0.74 to 1.14, at one year and 1.13, 0.93 to 1.37, at six years). There was a tendency towards fewer removals for pain in early years but no difference at six years (relative risk 1.13, 95% confidence intervals 0.93 to 1.37). AUTHORS' CONCLUSIONS There is insufficient data to show that problems of early expulsions have been overcome with the modified introducer used in GyneFix. Apart from that, the frameless device performs similarly to TCu380, and appears to have a lower pregnancy rate in later years, although the absolute difference is small.
Collapse
Affiliation(s)
- P A O'Brien
- Services for Women, Parkside Health, St Charles Hospital, Exmoor St, London, UK, W10 6DZ.
| | | |
Collapse
|
11
|
Abstract
BACKGROUND The frameless intrauterine device (IUD) dispenses with the frame in the classical IUD and holds the device in the uterus by anchoring one end of a nylon thread in the fundal myometrium, to which copper sleeves are attached. The introducer for the frameless device was modified following reports of early expulsions of the device. OBJECTIVES This review examines the hypothesis that the frameless device reduces risk of expulsion and pregnancy, and the problems of bleeding and pain necessitating early removal. SEARCH STRATEGY We searched the Cochrane Controlled Trial Register (Cochrane Library Issue 1, 2001), MEDLINE, EMBASE and Popline to Dec 2000, and reference list of articles. SELECTION CRITERIA We selected for the review randomised trials that compared the frameless device to a classical framed device for contraception. DATA COLLECTION AND ANALYSIS Both authors extracted data independently. We contacted study author for additional data. We calculated rate ratios and rate differences for cumulative rates for each outcome at yearly intervals. We used the general variance-based method to combine trials, and tested the results for heterogeneity. MAIN RESULTS Three trials were included in the review involving over 5,800 women randomised to either a frameless device or TCu380A, with data up to eight years for the largest, and with a total experience of 23,000 women-years. All three trials excluded nulliparous women. The two earlier trials used a prototype introducer and there was a higher expulsion rate at one year (relative risk 2.48, 95% confidence intervals 1.89 to 3.26). However, between two and six years in the large WHO trial the risk of pregnancy was lower with the frameless device (relative risk 0.53, 95% confidence intervals 0.32 to 0.91). In a recent trial using GyneFix with a new introducer early expulsions and pregnancies were not statistically different from the control device; by the third year the expulsion rate with the frameless device was lower (relative risk 0.41, 95% confidence intervals 0.19 to 0.87) with no difference in pregnancy rate. Removals rates for excessive bleeding and/or pain were no different between the devices (relative risks 0.92, 95% confidence intervals 0.74 to 1.14, at one year and 1.13, 0.93 to 1.37, at six years). There was a tendency towards fewer removals for pain in early years but no difference at six years (relative risk 1.13, 95% confidence intervals 0.93 to 1.37). REVIEWER'S CONCLUSIONS There are insufficient data to show that problems of early expulsions have been overcome with the new introducer used in GyneFix. Apart from that, the frameless device performs similarly to TCu380A, and appears to have a lower pregnancy rate in later years, although the absolute difference is small.
Collapse
Affiliation(s)
- P A O'Brien
- Services for Women, Parkside Health, St Charles Hospital, Exmoor St, London, UK, W10 6DZ.
| | | |
Collapse
|
12
|
Farr G, Amatya R. Contraceptive efficacy of the Copper T 380A and Copper T 200 intrauterine devices: results from a comparative clinical trial in six developing countries. Contraception 1994; 49:231-43. [PMID: 8200217 DOI: 10.1016/0010-7824(94)90041-8] [Citation(s) in RCA: 24] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/29/2023]
Abstract
The clinical performance of the Copper T 380A (TCu 380A) and the Copper T 200 (TCu 200) intrauterine devices (IUDs) was evaluated for 12 months in a group of women who had one of the two IUDs inserted. Results are from a multicenter randomized clinical trial at one site in each of six developing countries. The pregnancy rate with the TCu 380A IUD was significantly lower than the pregnancy rate with the TCu 200 IUD at 12 months (0.5 and 2.6 per 100 women, respectively, p < 0.01). No statistically significant differences between the two study IUDs were found with regards to expulsion or removals due to bleeding/pain, personal, medical, or planned pregnancy. The TCu 380A IUD did not have a disproportionately higher incidence of side effects such as intermenstrual bleeding or pain, inflammations or infections, or insertion-related events compared to the TCu 200 IUD. TCu 380A IUD users, however, were significantly more likely to report increased dysmenorrhea than were TCu 200 IUD users. The performance of the TCu 380A IUD in preventing pregnancy during this trial indicates that this IUD may be a better option than the TCu 200 IUD for women wishing to practice effective, long-term, reversible birth control without having to resort to hormonal methods.
Collapse
Affiliation(s)
- G Farr
- Family Health International, Research Triangle Park, North Carolina 27709
| | | |
Collapse
|
13
|
Edelman DA, Porter CW. The new intrauterine contraceptive devices: safe and effective. ADVANCES IN CONTRACEPTION : THE OFFICIAL JOURNAL OF THE SOCIETY FOR THE ADVANCEMENT OF CONTRACEPTION 1993; 9:83-91. [PMID: 8342459 DOI: 10.1007/bf02115905] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/30/2023]
Abstract
Reviews of the safety of intrauterine contraception usually are based on studies that do not reflect changes in clinical practice that have occurred over time, and that include many types of IUDs that are no longer used. Studies of insertions of the Multiload 375 and Copper T 380 performed since 1980, which more accurately reflect current clinical practice, show that these IUDs provide a high level of protection against pregnancy and are associated with low rates of complications. Current clinical opinion regarding the safety of IUDs needs to be reassessed in light of the positive safety record of these IUDs.
Collapse
Affiliation(s)
- D A Edelman
- Medical Research Consultants, Madison, NJ 07940
| | | |
Collapse
|
14
|
A multicenter study of the clinical performance of the Ortho Gyne-T380 Slimline intrauterine device in routine use in general practice and family planning clinics. ACTA ACUST UNITED AC 1993. [DOI: 10.1007/bf02115901] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
|
15
|
Sivin I, Diaz J, Alvarez F, Brache V, Diaz S, Pavez M, Stern J. Four-year experience in a randomized study of the Gyne T 380 Slimline and the Standard Gyne T 380 intrauterine copper devices. Contraception 1993; 47:37-42. [PMID: 8436000 DOI: 10.1016/0010-7824(93)90107-i] [Citation(s) in RCA: 18] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/30/2023]
Abstract
Performance of the Slimline and Standard models of the Gyne T 380 were measured through four years in a comparative study initially involving 996 women, seventy percent of whom were randomized to the Slimline device. Cumulative pregnancy rates of Slimline users were 0.3 +/- 0.2 per 100 both at three and at four years, as compared with rates of 1.5 +/- 0.9 and 3.8 +/- 1.7 at the same intervals for users of the Standard model (P > .05). The four-year explusion rate of the Slimline, 8.6 +/- 1.3 per 100, was significantly higher than the comparable rate of the Standard model, 4.4 +/- 1.6 (P < .05). The two Gyne T* models did not differ in continuation rates. First time IUD users, however, had substantially lower continuation rates than did former users (P < .001), in consequence of their relative youth and desire to have additional children. Other performance measures did not differ importantly by device.
Collapse
Affiliation(s)
- I Sivin
- Population Council, Center for Biomedical Research, New York, New York 10021
| | | | | | | | | | | | | |
Collapse
|
16
|
Sivin I, Diaz S, Pavez M, Alvarez F, Branche V, Diaz J, Odlind V, Olsson SE, Stern J. Two-year comparative trial of the Gyne T* 380 Slimline and Gyne T* 380 intrauterine copper devices. Contraception 1991; 44:481-7. [PMID: 1797463 DOI: 10.1016/0010-7824(91)90150-e] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/28/2022]
Abstract
In a randomized trial of the Gyne T* 380 Slimline, the-two year pregnancy rate was 0.3 per 100 and the continuation rate was 65 per 100. These rates did not differ statistically from those of the standard Gyne T* 380, nor did other performance parameters differ between devices by the log-rank test. Women under age 30 had lower continuation rates using either device than did women age 30 or older at admission because of removals for planned pregnancy. Conception rates among those who desired pregnancy were 35 per 100 at one month and 86 per 100 at one year.
Collapse
Affiliation(s)
- I Sivin
- Population Council, Center for Biomedical Research, New York, NY 10021
| | | | | | | | | | | | | | | | | |
Collapse
|