1
|
Wang K, Bao G, Fan Q, Zhu L, Yang L, Liu T, Zhang Z, Li G, Chen X, Xu X, Xu X, He B, Zheng Y. Feasibility evaluation of a Cu-38 Zn alloy for intrauterine devices: In vitro and in vivo studies. Acta Biomater 2022; 138:561-575. [PMID: 34774783 DOI: 10.1016/j.actbio.2021.11.006] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/16/2021] [Revised: 10/29/2021] [Accepted: 11/04/2021] [Indexed: 11/01/2022]
Abstract
The existing adverse effects of copper in copper-containing intrauterine devices (Cu-IUDs) have raised concerns regarding their use. These adverse effects include burst release of cupric ions (Cu2+) at the initial stage and an increasingly rough surface of the Cu-IUDs. In this study, we investigated the use of two copper alloys, Cu-38 Zn and H62 as the new upgrading or alternative material for IUDs. Their corrosive properties were studied in simulated uterine fluid (SUF) by using electrochemical methods, with pure Cu as a control. We studied the in vitro long-term corrosion behaviors in SUF, cytotoxicity to uterine cells (human endometrial epithelial cells and human endometrial stromal cells), in vivo biocompatibility and contraceptive efficacy of pure Cu, H62, and Cu-38 Zn. In the first month, the burst release rate of Cu2+ in the Cu-38 Zn group was significantly lower than those in the pure Cu and H62 groups. The in vitro cytocompatibility Cu-38 Zn was better than that of pure Cu and H62. Moreover, Cu-38 Zn showed improved tissue biocompatibility in vivo experiments. Therefore, the contraceptive efficacy of the Cu-38 Zn is still maintained as high as the pure Cu while the adverse effects are significantly eased, suggesting that Cu-38 Zn can be a suitable potential candidate material for IUDs. STATEMENT OF SIGNIFICANCE: The existing adverse effects associated with the intrinsic properties of copper materials for copper-containing intrauterine devices (Cu-IUD) are of concern in their employment. Such as, burst release of cupric ions (Cu2+) at the initial stage and an increasingly rough surface of the Cu-IUD. In this work, Cu alloyed with a high amount of bioactive Zn was used for a Cu-IUD. The Cu-38 Zn alloy exhibited reduced burst release of Cu2+ within the first month compared with the pure Cu and H62. Furthermore, the Cu-38 Zn alloy displayed significantly improved biocompatibility and a much smoother surface. Therefore, high antifertility efficacy of the Cu-38 Zn alloy was well maintained, while the adverse effects are significantly eased, suggesting that the Cu-38 Zn alloy is promising for a Cu-IUD.
Collapse
|
2
|
Akintomide H, Brima N, Sewell RDE, Stephenson JM. Patients’ experiences and providers’ observations on pain during intrauterine device insertion. EUR J CONTRACEP REPR 2015; 20:319-26. [DOI: 10.3109/13625187.2015.1031885] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/03/2023]
|
3
|
Effective inhibition of the early copper ion burst release with ultra-fine grained copper and single crystal copper for intrauterine device application. Acta Biomater 2012; 8:886-96. [PMID: 22040688 DOI: 10.1016/j.actbio.2011.10.018] [Citation(s) in RCA: 34] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/08/2011] [Revised: 09/08/2011] [Accepted: 10/13/2011] [Indexed: 11/24/2022]
Abstract
To solve the main problems of existing coarse grained copper (CG Cu) intrauterine devices (IUD)-namely burst release and a low transfer efficiency of the cupric ions during usage-ultra-fine grained copper (UFG Cu) and single crystal copper (SC Cu) have been investigated as potential substitutes. Their corrosion properties with CG Cu as a control have been studied in simulated uterine fluid (SUF) under different conditions using electrochemical measurement methods. Long-term immersion of UFG Cu, SC Cu and CG Cu samples in SUF at 37 °C have been studied for 300 days. A lower copper ion burst release and a higher efficiency release of cupric ions were observed for UFG Cu and SC Cu compared with CG Cu in the first month of immersion and 2 months later. The respective corrosion mechanisms for UFG Cu, SC Cu and CG Cu in SUF are proposed. In vitro biocompatibility tests show a better cellular response to UFG Cu and SC Cu than CG Cu. In terms of instantaneous corrosion behavior, long-term corrosion performance and in vitro biocompatibility, the three pure copper materials follow the order: UFG Cu>SC Cu>CG Cu, which indicates that UFG Cu could be the most suitable candidate material for intrauterine devices.
Collapse
|
4
|
Xu X, Macaluso M, Frost J, Anderson JE, Curtis K, Grosse SD. Characteristics of users of intrauterine devices and other reversible contraceptive methods in the United States. Fertil Steril 2011; 96:1138-44. [PMID: 21917255 DOI: 10.1016/j.fertnstert.2011.08.019] [Citation(s) in RCA: 20] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/10/2011] [Revised: 08/12/2011] [Accepted: 08/12/2011] [Indexed: 01/18/2023]
Abstract
OBJECTIVE To evaluate the determinants of intrauterine device (IUD) use and reasons for choosing IUDs over other reversible contraceptive methods. DESIGN Descriptive statistics and multinomial logistic regression were used to assess multiple factors associated with IUD use and the use of other reversible methods in the United States. SETTING Not applicable. PATIENT(S) Women at risk of pregnancy from the 2006 to 2008 National Survey of Family Growth and a 2004 Guttmacher Institute survey. INTERVENTION(S) None. MAIN OUTCOME MEASURE(S) Sociodemographic and reproductive characteristics, family background, and health insurance coverage. RESULT(S) IUD use was positively associated with women's parity and the highest education level of respondent's mother; it was less common among women who had ≥4 sexual partners in the last 12 months and those who were widowed, divorced, or separated. IUD users reported pregnancy prevention, provider recommendation, and no interruption of sex as the most important reasons for choosing the method and reported a high level of satisfaction. CONCLUSION(S) IUD users differed substantially from users of other reversible contraceptives. IUD use was especially uncommon among nulliparae. Most current IUD users were satisfied with their choice.
Collapse
Affiliation(s)
- Xin Xu
- Division of Reproductive Health, Centers for Disease Control and Prevention, Atlanta, Georgia, USA.
| | | | | | | | | | | |
Collapse
|
5
|
Mansour D, Inki P, Gemzell-Danielsson K. Efficacy of contraceptive methods: A review of the literature. EUR J CONTRACEP REPR 2010; 15:4-16. [DOI: 10.3109/13625180903427675] [Citation(s) in RCA: 90] [Impact Index Per Article: 6.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/13/2022]
|
6
|
Copper-containing, framed intrauterine devices for contraception: a systematic review of randomized controlled trials. Contraception 2008; 77:318-27. [DOI: 10.1016/j.contraception.2007.12.011] [Citation(s) in RCA: 58] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/30/2007] [Revised: 12/21/2007] [Accepted: 12/21/2007] [Indexed: 11/22/2022]
|
7
|
Thonneau PF, Almont T. Contraceptive efficacy of intrauterine devices. Am J Obstet Gynecol 2008; 198:248-53. [PMID: 18221924 DOI: 10.1016/j.ajog.2007.10.787] [Citation(s) in RCA: 54] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/07/2007] [Revised: 10/01/2007] [Accepted: 10/01/2007] [Indexed: 11/17/2022]
Abstract
To compare the contraceptive efficacy of various types of intrauterine devices (IUD; copper devices, Nova-T, intrauterine contraceptive systems, levonorgestrel-releasing devices), we reviewed all relevant publications on this subject that have been published over the last 2 decades. The first point to be highlighted by this review is the excellent effectiveness of IUDs, with a global cumulative pregnancy rate <2% at 5 years, whatever the type of device used. We observed a large variation in efficacy rate according to the type of IUD and also according to study design. Nevertheless, of all the types of IUDs, the levonorgestrel-releasing IUD and to a lesser extent the TCu380A IUD seem to be the most effective, with a cumulative pregnancy rate at 5 years of <0.5% for the levonorgestrel-releasing IUD and between 0.3% and 0.6% for the TCu380A IUD.
Collapse
|
8
|
Pregnancy Risk Among Oral Contraceptive Pill, Injectable Contraceptive, and Condom Users in Uganda, Zimbabwe, and Thailand. Obstet Gynecol 2007; 110:1003-9. [DOI: 10.1097/01.aog.0000268804.98744.2b] [Citation(s) in RCA: 13] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
|
9
|
Kulier R, O'Brien PA, Helmerhorst FM, Usher-Patel M, D'Arcangues C. Copper containing, framed intra-uterine devices for contraception. Cochrane Database Syst Rev 2007:CD005347. [PMID: 17943851 DOI: 10.1002/14651858.cd005347.pub3] [Citation(s) in RCA: 36] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
Abstract
BACKGROUND Intrauterine devices (IUD) are safe and effective methods of long term reversible contraception. The design, and copper content as well as placement of the copper on IUDs could affect their effectiveness and side-effect profile. OBJECTIVES We compared different copper IUDs for their effectiveness and side effects. SEARCH STRATEGY Multiple electronic databases were searched with appropriate key words and names of the IUDs known to be in the market. We searched the reference lists of papers identified and contacted trialists when possible. There was no language restriction. SELECTION CRITERIA Randomised controlled trials comparing different IUDs were considered. Trials needed to report on clinical outcomes. DATA COLLECTION AND ANALYSIS Data on outcomes and trial characteristics were extracted in duplicate and independently by two reviewers. Meta-analysis results are expressed as rate difference (RD) using a fixed-effects model with 95% confidence interval (CI). In the presence of significant heterogeneity a random-effects model was applied. MAIN RESULTS We included 35 trials, resulting in 18 comparisons of 10 different IUDs in approximately 48,000 women. TCu380A was more effective in preventing pregnancy than MLCu375 (RD 1.70%, 95% CI 0.07% to 2.95% after 4 years of use). TCu380A was also more effective than MLCu250, TCu220 and TCu200. There tended to be fewer pregnancies with TCu380S compared to TCu380A after the first year of use, a difference which was statistically significant in the fourth year (RD -1.62%, 95% CI -3.00% to -0.24%). This occurred despite more expulsions with TCu380S (RD 3.50%, 95% CI 0.36% to 6.63% at 4 years). MLCu375 was no more effective than TCu220 at 1 year of use, or MLCu250 and NovaT up to 3 years. Compared to TCu380A or TCu380S, none of the IUDs showed any benefits in terms of bleeding or pain, or any of the other reasons for early discontinuation. None of the trials that reported events at insertion found one IUD easier to insert than another or caused less pain at insertion. There is no evidence that uterine perforation rates vary by type of device. There are minimal randomised data on IUD use in nulliparous women. AUTHORS' CONCLUSIONS TCu380A or TCu380S appear to be more effective than other IUDs. No IUD showed consistently lower removal rates for bleeding and pain in comparison to other IUDs. There is no evidence that any particular framed copper device is better suited to women who have not had children.
Collapse
Affiliation(s)
- R Kulier
- Geneva Foundation for Medical Education and Research, Route de Florissant 3, Geneva, Switzerland, CH-1208,
| | | | | | | | | |
Collapse
|
10
|
Hubacher D, Reyes V, Lillo S, Zepeda A, Chen PL, Croxatto H. Pain from copper intrauterine device insertion: randomized trial of prophylactic ibuprofen. Am J Obstet Gynecol 2006; 195:1272-7. [PMID: 17074548 DOI: 10.1016/j.ajog.2006.08.022] [Citation(s) in RCA: 124] [Impact Index Per Article: 6.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/25/2006] [Revised: 07/07/2006] [Accepted: 08/31/2006] [Indexed: 10/23/2022]
Abstract
OBJECTIVES This study was undertaken to determine whether 400 mg of prophylactic ibuprofen can alleviate pain from insertion of an intrauterine device (IUD) and to measure level of pain with improved techniques. STUDY DESIGN We conducted a randomized, double-blind, placebo-controlled trial of 2019 first-time IUD users: 1008 women received placebo and 1011 women received 400 mg of ibuprofen. Participants took the single tablet at least 45 minutes before IUD insertion. Immediately after insertion, participants recorded level of pain by using a 10-cm visual analog scale, with the value of 10 meaning "worst imaginable pain." RESULTS Median level of pain was 1.0 for both ibuprofen and placebo participants; rank test statistics confirmed no difference. Some subgroups of women experienced higher pain (eg, nulliparous women), but ibuprofen still had no important impact on level of pain. CONCLUSION Even among first-time users, pain from IUD insertion is generally low. Prophylactic ibuprofen as used in this protocol does not reduce IUD insertion pain.
Collapse
Affiliation(s)
- David Hubacher
- Family Health International, Research Triangle Park, NC, USA
| | | | | | | | | | | |
Collapse
|
11
|
Kulier R, Helmerhorst FM, O'Brien P, Usher-Patel M, d'Arcangues C. Copper containing, framed intra-uterine devices for contraception. Cochrane Database Syst Rev 2006:CD005347. [PMID: 16856094 DOI: 10.1002/14651858.cd005347.pub2] [Citation(s) in RCA: 13] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
Abstract
BACKGROUND Intrauterine devices (IUD) are safe and effective methods of long term reversible contraception. Design and copper content of IUDs could affect their effectiveness and side-effect profile. OBJECTIVES We compared different copper IUDs for their effectiveness and side effects. SEARCH STRATEGY Multiple electronic databases were searched with appropriate key words and names of the IUDs known to be in the market. We searched the reference lists of papers identified and contacted trialists when possible. SELECTION CRITERIA Randomised controlled trials comparing different IUDs were considered. Trials needed to report on clinical outcomes. DATA COLLECTION AND ANALYSIS Data on outcomes and trial characteristics were extracted in duplicate and independently by two reviewers. Meta-analysis results are expressed as rate difference (RD) using a fixed-effects model with 95% confidence interval (CI). In the presence of significant heterogeneity a random-effects model was applied. MAIN RESULTS We included 34 trials, resulting in 16 comparisons of different IUDs. TCu380A was more effective than MLCu375, MLCu250, TCu220 and TCu200. Changing the position of the copper on the arm of the IUD for TCu380S did not improve the efficacy of TCu380A. MLCu375 was no more effective than TCu220, at 1 year, MLCu250 to 3 years or NovaT to 3 years Compared to TCu380A, none of the IUDs showed any benefits in terms of bleeding or pain, or any of the other reasons for early discontinuation. AUTHORS' CONCLUSIONS TCu380A is more effective compared to other IUDs. There is no data available comparing different IUDs in special subgroups, such as nulliparous women.
Collapse
Affiliation(s)
- R Kulier
- Geneva Foundation for Medical Education and Research, Route de Florissant 3, Geneva, Switzerland CH-1208.
| | | | | | | | | |
Collapse
|
12
|
Salhan S, Tripathi V. Factors influencing discontinuation of intrauterine contraceptive devices: an assessment in the Indian context. EUR J CONTRACEP REPR 2005; 9:245-59. [PMID: 15799182 DOI: 10.1080/13625180400017495] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/26/2022]
Abstract
Sociocultural and behavioral factors are associated with decision to use and the selection of a contraceptive method, continuation of use and reasons for discontinuation of a contraceptive. This paper tries to distinctly outline the determinants of discontinuation of the intrauterine contraceptive device (IUCD), especially in the Indian context. Data on medical reasons for discontinuation are available through clinical trials. However, sociodemographic studies provide one with a wider spectrum to analyze the factors associated with the discontinuation of IUCDs. Information on service providers can be used to improve the quality of family planning services in the country. In India, a thorough review of birth spacing methods, especially the IUCD, is needed since the surveys show a high rate of discontinuation. The emphasis in this paper is upon compilation of reasons for discontinuation of the IUCD and research thereof. The review of the literature is directed towards giving a new direction to assessment of family planning programs, especially in India where population control is largely dependent upon permanent methods. Delineation of factors is important to improve the family planning program.
Collapse
Affiliation(s)
- S Salhan
- Department of Obstetrics and Gynaecology, V M Medical College & Safdarjung Hospital, New Delhi, India
| | | |
Collapse
|
13
|
Stanford JB, Mikolajczyk RT. Mechanisms of action of intrauterine devices: update and estimation of postfertilization effects. Am J Obstet Gynecol 2002; 187:1699-708. [PMID: 12501086 DOI: 10.1067/mob.2002.128091] [Citation(s) in RCA: 123] [Impact Index Per Article: 5.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/17/2022]
Abstract
There are many potential mechanisms of action for the intrauterine device (IUD), which vary by type of IUD (inert, copper, or hormonal). This paper reviews the evidence for each potential mechanism of action. On the basis of available data for fertilization rates and clinical pregnancy rates, the relative contribution of mechanisms acting before or after fertilization were quantitatively estimated. These estimates indicate that, although prefertilization effects are more prominent for the copper IUD, both prefertilization and postfertilization mechanisms of action contribute significantly to the effectiveness of all types of intrauterine devices.
Collapse
Affiliation(s)
- Joseph B Stanford
- Department of Family and Preventive Medicine, University of Utah Health Research Center, Salt Lake City 84108, USA.
| | | |
Collapse
|
14
|
Batár I, Kuukankorpi A, Siljander M, Elomaa K, Rauramo I. Five-year clinical experiences with NOVA T 380 copper IUD. Contraception 2002; 66:309-14. [PMID: 12443960 DOI: 10.1016/s0010-7824(02)00385-2] [Citation(s) in RCA: 16] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/27/2022]
Abstract
In an open, single-group, phase III clinical trial of 5 years, the clinical performance of NOVA T 380 was investigated in three centers. The device having a higher copper surface of 380 mm(2) is a modification of NOVA T. A total of 400 voluntary women were enrolled in the study. The mean age was 31.4 years (SD 5.5) with the minimum of 18 and the maximum of 44 years. At the end of the study, 211 women had passed the 60-month visit. Cumulative discontinuation rates at the end of the first and the fifth year calculated by Kaplan-Meier estimates, were respectively as follows: pregnancy 0.5 and 1.9, expulsion 1.3 and 4.1, bleeding 4.4 and 14.0, pain 1.3 and 4.2, removal for other medical reason 1.4 and 6.4, planning pregnancy 0.8 and 13.5, and removal for other personal reason 2.4 and 11.9 per 100 users. Neither ectopic pregnancies nor episodes of pelvic inflammatory diseases (PIDs) occurred. One perforation was recorded; the calculated rate is 0.3 per 100 women (first year). The continuation rate was 88.3 and 52.5 at 1 and 5 years, respectively. In conclusion, the 5-year performance of NOVA T 380 was good compared to other "high-loaded" copper devices. Safety was acceptable over the entire study period.
Collapse
Affiliation(s)
- I Batár
- Department of Obstetrics and Gynecology, University of Debrecen, Debrecen, Hungary.
| | | | | | | | | |
Collapse
|
15
|
Stanwood NL, Grimes DA, Schulz KF. Insertion of an intrauterine contraceptive device after induced or spontaneous abortion: a review of the evidence. BJOG 2001; 108:1168-73. [PMID: 11762657 DOI: 10.1111/j.1471-0528.2003.00264.x] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
Abstract
OBJECTIVE Assess the safety and efficacy of intrauterine contraceptive device (IUCD) insertion immediately after induced or spontaneous abortion. DESIGN Systematic search for randomised trials that had at least one treatment arm that involved IUCD insertion immediately after an induced or spontaneous miscarriage using Medline, Popline, EMBASE, and review articles supplemented by correspondence with investigators. POPULATION Women of any age or gravidity who had an IUCD inserted immediately after evacuation for spontaneous or induced abortion. METHODS Articles were abstracted and the raw data from tables were analysed with RevMan 3.1 software. We focused on Tietze-Potter gross life table probabilities with denominators of person-time of exposure. MAIN OUTCOME MEASURES Rates of perforation, expulsion, pelvic inflammatory disease, contraceptive failure, and method continuation. RESULTS Complication rates for immediate post-abortal IUCD insertion were low. Perforation was rare with a rate of approximately one per 1,000 insertions. One year gross cumulative expulsion rates ranged from 1.8% to 12.6%, pregnancy rates from 0.6% to 2.1%, and continuation rates from 54% to 90%. The net discontinuation rate due to pelvic inflammatory disease was low, ranging from 0.0 to 0.8 per 100 women at one year. Increasing gestational age at insertion was associated with increased expulsion rates. CONCLUSIONS Post-abortal IUCD insertion is safe and effective. The risks of perforation, expulsion, pelvic inflammatory disease and contraceptive failure were low and similar to those reported for interval insertion. Second trimester gestational age is associated with an increased risk of expulsion. Immediate insertion may have a higher expulsion rate than delayed insertion. However, these risks may be outweighed by the benefit of immediate contraception.
Collapse
Affiliation(s)
- N L Stanwood
- Robert Wood Johnson Clinical Scholars Program, University of North Carolina School of Medicine, Chapel Hill, USA
| | | | | |
Collapse
|
16
|
Insertion of an intrauterine contraceptive device after induced or spontaneous abortion: a review of the evidence. ACTA ACUST UNITED AC 2001. [DOI: 10.1016/s0306-5456(01)00264-9] [Citation(s) in RCA: 14] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/24/2022]
|
17
|
Fordyce G, Jubb TF, Fitzpatrick LA, Whyte TR, Cooper NJ, Bolam MJ, Haddon DJ, Hill F, D'Occhio MJ. Contraceptive efficacy of an intra-uterine device in Brahman cattle. Anim Reprod Sci 2001; 65:193-204. [PMID: 11267799 DOI: 10.1016/s0378-4320(01)00081-1] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/27/2022]
Abstract
The contraceptive efficacy of an intra-uterine device was evaluated using 218 heifers and 212 cows on three north Australian cattle stations. The heifers were aged approximately 2 years and weighed 250-378 kg; the cows were aged 3-16 years and weighed 256-540 kg. All cattle were non-pregnant, non-lactating Brahmans. At the end of the monsoon (wet) season (April-June 1997), the cattle were allocated by stratified randomisation to the three treatments which were untreated controls (n=59), surgical ovariectomy (n=105), or implantation with a bovine intra-uterine device (BIUD; n=266). All cattle grazed and were managed as one group within each station. They were exposed to bulls (4 per 100 females) from soon after treatment until slaughter approximately 12 months later. The BIUD could not be implanted in 25% of heifers and 8% of cows due to narrow or twisted cervices. Correct placement of the BIUDs appeared to be achieved in 57% of heifers and 72% of cows. At slaughter, the devices were incorrectly positioned in 73% of heifers and 49% of cows into which BIUDs had been inserted and that remained non-pregnant. Uterine perforations by the BIUD were observed in 35 and 45% of these heifers and cows, respectively; most perforations appeared to occur during implantation. Low-grade endometritis was observed at slaughter in most BIUD-implanted animals; 2% had pyometra.BIUD animals did not have significantly different growth to that of control or ovariectomised animals, other than when ovariectomy suppressed growth following surgery. Most animals implanted with BIUDs appeared to have normal ovarian function and animals were observed mating. All ovariectomised animals remained non-pregnant. Over 80% of controls were pregnant within 8 months of exposure to bulls, except heifers at one station where pregnancy rate was restricted to 25% as a result of severe nutritional conditions. Pregnancy was diagnosed in 21% of heifers and 33% of cows with implanted BIUDs. The device remained correctly positioned and with no pregnancy diagnosed in the year following implantation in only 2% of heifers and 14% of cows originally allocated. Because of the difficulties of implanting BIUDs, the high frequency of associated uterine injury, the high pregnancy rate in implanted animals, and that growth was unaffected by the presence of a BIUD, it was concluded that the device had poor contraception efficacy and no growth-promotant effect in Brahman cattle.
Collapse
Affiliation(s)
- G Fordyce
- Department of Primary Industries, Queensland Beef Industry Institute, P.O. Box 976, Qld. 4820, Charters Towers, Australia.
| | | | | | | | | | | | | | | | | |
Collapse
|
18
|
Reinprayoon D, Gilmore C, Farr G, Amatya R. Twelve-month comparative multicenter study of the TCu 380A and ML 250 intrauterine devices in Bangkok, Thailand. Contraception 1998; 58:201-6. [PMID: 9865999 DOI: 10.1016/s0010-7824(98)00097-3] [Citation(s) in RCA: 14] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
Abstract
The long-term effectiveness of the copper-bearing intrauterine device (IUD) has been documented. This paper reports 12-month results from a multiyear comparative study of the Copper T (TCu) 380A and Multiload (ML) 250 IUD in Bangkok, Thailand, among 1396 women. Continuation of the assigned IUD was relatively high after 12 months of use, with continuation rates of 90.17 and 87.54 per 100 women, respectively. Whereas the accidental pregnancy rate was higher for the ML 250 IUD than for the TCu 380A IUD (1.0 and 0.2 per 100 women, respectively), this difference was not considered statistically significant (p < 0.69). The rate of IUD expulsion was significantly higher among women using the ML 250 IUD than for women using the TCu 380A IUD (4.61 and 2.40 per 100 women, respectively, p = 0.05).
Collapse
Affiliation(s)
- D Reinprayoon
- Department of Obstetrics and Gynaecology, Chulalongkorn University, Bangkok, Thailand
| | | | | | | |
Collapse
|
19
|
|
20
|
Turin EM, Nagle CA, Lahoz M, Torres M, Turin M, Mendizabal AF, Escofet MB. Effects of a copper-bearing intrauterine device on the ovarian function, body weight gain and pregnancy rate of nulliparous heifers. Theriogenology 1997; 47:1327-36. [PMID: 16728080 DOI: 10.1016/s0093-691x(97)00125-8] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/16/1996] [Accepted: 09/09/1996] [Indexed: 11/25/2022]
Abstract
A copper-bearing intrauterine device (IUD), designed to cause a slight distention of the uterus, was inserted through the cervix into each uterine horn of 230 heifers; an additional 230 heifers served as the control group. Blood was drawn at 0, 1, 2, 20 and 120 d for progesterone and testosterone assays. The heifers were checked twice daily for estrus and examined at 0, 60 and 120 d for weight gain. Thereafter they were bred over a 120-d period. The IUD caused anestrus in 98% of the heifers, with a daily weight gain 25.5 % higher than in the control heifers. Moreover, the device was 100% effective in preventing pregnancy. At 20 and 120 d after IUD insertion progesterone levels averaged 0.7 ng/ml, which was 4 to 5 times lower than in the control animals, suggesting a failure in ovulation or in corpus luteum (CL) formation due to the IUD. Simultaneously, testosterone values were increased up to 8 times in IUD-treated heifers, reaching a mean concentration of 163 pg/ml. Associated histological evaluations of the ovaries from UD-treated heifers revealed the presence of 2 or more cysts per ovary, with marked hyperthecosis in many antral follicles in which the granulosa cell layers were either thinned or lacking. The results suggest that the action of the copper-releasing IUD used in this study resulted in high contraceptive efficiency but also in disturbance of ovarian function. Our findings further raise the possibility of a cause and effect relationship between hyperandrogenism and the higher body weight gain observed in heifers treated with the IUD.
Collapse
Affiliation(s)
- E M Turin
- Centro de Investigacion en Reproduccion Humana y Experimental del Centro de Educacion Medica e Investigaciones Clinicas (CEMIC) Buenos Aires, Argentina
| | | | | | | | | | | | | |
Collapse
|
21
|
|
22
|
Farr G, Amatya R, Acosta M, Ekwempu C, Kisninci H. Clinical performance of the TCu 380A and Lippes Loop IUDs in three developing countries. Contraception 1995; 52:17-22. [PMID: 8521710 DOI: 10.1016/0010-7824(95)00119-u] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/31/2023]
Abstract
The clinical performance of the Copper T 380A (TCu 380A) and the Lippes Loop intrauterine devices (IUDs) were evaluated for 12 months in a group of 710 women who had one of the two IUDs inserted. Results are from a randomized clinical trial conducted at three collaborating research sites located in three developing countries. The gross cumulative life-table pregnancy rate of the TCu 380A IUD was found to be lower than that of the Lippes Loop IUD at 12 months (0.7 and 2.1 per women, respectively). Although this difference was not statistically significant (p = 0.25), it is similar to findings from other studies. The 12-month cumulative removal rate due to personal reasons was significantly different (1.4 and 0.0, respectively, p = 0.05). Statistically significant differences between the two study IUDs were not found with regard to IUD expulsion or IUD removal due to bleeding/pain, medical reasons, planned pregnancy or investigator's choice. A statistically significant difference (p = 0.03) was observed in the number of TCu 380A IUD users experiencing dysmenorrhea (26.1%) during the 12-month study period, compared to Lippes Loop IUD users (18.8%).
Collapse
Affiliation(s)
- G Farr
- Family Health International, Research Triangle Park, North Carolina 27709, USA
| | | | | | | | | |
Collapse
|
23
|
Van Kets HE, Van der Pas H, Delbarge W, Thiery M. A randomized comparative study of the TCu380A and Cu-Safe 300 IUDs. ADVANCES IN CONTRACEPTION : THE OFFICIAL JOURNAL OF THE SOCIETY FOR THE ADVANCEMENT OF CONTRACEPTION 1995; 11:123-9. [PMID: 7491853 DOI: 10.1007/bf01987277] [Citation(s) in RCA: 13] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/25/2023]
Abstract
The Cu-Safe 300 is one of the latest additions to the array of available IUDs. It was specifically designed to decrease unwanted side-effects (e.g. bleeding, pain and expulsion) while providing simplicity of insertion, ease of removal and fair contraceptive protection. For comparison, the TCu380A was chosen. Both types were inserted at random in 600 recipients by a group of independent physicians with a long standing experience in intrauterine contraception. Life table analysis was used for comparison over a period of three years. The Cu-Safe 300 produced a slightly but not statistically significant higher pregnancy rate and more expulsions. Removals for bleeding and pain, however, were significantly less frequent. All inserting physicians agreed that insertion and removal of this new device was remarkably easy.
Collapse
Affiliation(s)
- H E Van Kets
- International Working Group on Intrauterine Drug Delivery, University Hospital of Gent, Belgium
| | | | | | | |
Collapse
|