1
|
Recently Developed Adsorbing Materials for Fluoride Removal from Water and Fluoride Analytical Determination Techniques: A Review. SUSTAINABILITY 2021. [DOI: 10.3390/su13137061] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/24/2023]
Abstract
In recent years, there has been an increase in public perception of the detrimental side-effects of fluoride to human health due to its effects on teeth and bones. Today, there is a plethora of techniques available for the removal of fluoride from drinking water. Among them, adsorption is a very prospective method because of its handy operation, cost efficiency, and high selectivity. Along with efforts to assist fluoride removal from drinking waters, extensive attention has been also paid to the accurate measurement of fluoride in water. Currently, the analytical methods that are used for fluoride determination can be classified into chromatographic methods (e.g., ionic chromatography), electrochemical methods (e.g., voltammetry, potentiometry, and polarography), spectroscopic methods (e.g., molecular absorption spectrometry), microfluidic analysis (e.g., flow injection analysis and sequential injection analysis), titration, and sensors. In this review article, we discuss the available techniques and the ongoing effort for achieving enhanced fluoride removal by applying novel adsorbents such as carbon-based materials (i.e., activated carbon, graphene oxide, and carbon nanotubes) and nanostructured materials, combining metals and their oxides or hydroxides as well as natural materials. Emphasis has been given to the use of lanthanum (La) in the modification of materials, both activated carbon and hybrid materials (i.e., La/Mg/Si-AC, La/MA, LaFeO3 NPs), and in the use of MgO nanostructures, which are found to exhibit an adsorption capacity of up to 29,131 mg g−1. The existing analytical methodologies and the current trends in analytical chemistry for fluoride determination in drinking water are also discussed.
Collapse
|
2
|
Rocha DP, Anjos GTC, Neri TS, Tronto J, Pinto FG, Silva SG, Coelho NMM. A flow injection procedure using Layered Double Hydroxide for on line pre-concentration of fluoride. Talanta 2017; 178:102-108. [PMID: 29136791 DOI: 10.1016/j.talanta.2017.09.015] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/23/2017] [Revised: 09/03/2017] [Accepted: 09/06/2017] [Indexed: 10/18/2022]
Abstract
This work showed a flow system designed with solenoid valves for preconcentration of fluoride using SPADNS method in water samples. The analyte was preconcentrated in a mini-column coated with Layered Double Hydroxides (LDH) used as adsorbent. Then, the fluoride ions were eluted with 0.5molL-1 sodium hydroxide and determined by spectrophotometry. The variables that affect the system such adsorbent mass, type of eluent, solutions flow rate, reagent concentration and pH effect were critically evaluated. Under optimized conditions, the detection limit, coefficient of variation, linear range and preconcentration factor were estimated at 15µgL-1 (99.7% confidence level), 0.8% (500µgL-1, n = 10), 50-500µgL-1 and 10, respectively. The accuracy of the method was evaluated by analysis of ALPHA APS 1076 (Simulated Rain Water) certified material, the values were not significantly different at a 95% level of confidence. The method was applied for fluoride determination in water samples and the levels found were below the maximum values established by Brazilian environmental and health legislations.
Collapse
Affiliation(s)
- Diego P Rocha
- Federal University of Uberlândia, Institute of Chemistry, Avenue João Naves de Ávila, 2121, Santa Mônica, Uberlândia, MG CEP 38400-902, Brazil
| | - Gabriel T C Anjos
- Federal University of Uberlândia, Institute of Chemistry, Avenue João Naves de Ávila, 2121, Santa Mônica, Uberlândia, MG CEP 38400-902, Brazil
| | - Thais S Neri
- Federal University of Uberlândia, Institute of Chemistry, Avenue João Naves de Ávila, 2121, Santa Mônica, Uberlândia, MG CEP 38400-902, Brazil
| | - Jairo Tronto
- Federal University of Viçosa, Campus de Rio Paranaíba, Institute of Exact and Technological Sciences, Rodovia MG-230 - Km 8, Rio Paranaíba, MG CEP 38810-000, Brazil
| | - Frederico G Pinto
- Federal University of Viçosa, Campus de Rio Paranaíba, Institute of Exact and Technological Sciences, Rodovia MG-230 - Km 8, Rio Paranaíba, MG CEP 38810-000, Brazil
| | - Sidnei G Silva
- Federal University of Uberlândia, Institute of Chemistry, Avenue João Naves de Ávila, 2121, Santa Mônica, Uberlândia, MG CEP 38400-902, Brazil
| | - Nívia M M Coelho
- Federal University of Uberlândia, Institute of Chemistry, Avenue João Naves de Ávila, 2121, Santa Mônica, Uberlândia, MG CEP 38400-902, Brazil.
| |
Collapse
|
3
|
Yahyavi H, Kaykhaii M, Mirmoghaddam M. Recent Developments in Methods of Analysis for Fluoride Determination. Crit Rev Anal Chem 2016; 46:106-21. [PMID: 26460519 DOI: 10.1080/10408347.2014.985814] [Citation(s) in RCA: 28] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/07/2022]
Abstract
This review covers current analytical techniques, instruments, and methodologies used in the analysis of fluoride in various matrices. Our comprehensive literature search showed that there is no recently published review article about analytical methodologies for fluoride. In this review, we explore chromatographic, spectroscopic, and electrochemical innovations appearing in the recent literature.
Collapse
Affiliation(s)
- Hossein Yahyavi
- a Department of Chemistry , Faculty of Sciences, University of Sistan and Baluchestan , Zahedan , Iran
| | - Massoud Kaykhaii
- a Department of Chemistry , Faculty of Sciences, University of Sistan and Baluchestan , Zahedan , Iran
| | - Majid Mirmoghaddam
- a Department of Chemistry , Faculty of Sciences, University of Sistan and Baluchestan , Zahedan , Iran
| |
Collapse
|
4
|
Environmental Applications: Waters, Sediments and Soils. ACTA ACUST UNITED AC 2008. [DOI: 10.1016/s0166-526x(08)00623-5] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register]
|
5
|
Sweileh JA. On-line flow injection solid sample introduction, leaching and potentiometric determination of fluoride in phosphate rock. Anal Chim Acta 2007; 581:168-73. [DOI: 10.1016/j.aca.2006.07.086] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/24/2006] [Revised: 07/31/2006] [Accepted: 07/31/2006] [Indexed: 11/24/2022]
|
6
|
Miró M, Estela JM, Cerdà V. Application of flowing-stream techniques to water analysis. Talanta 2004; 62:1-15. [DOI: 10.1016/s0039-9140(03)00415-6] [Citation(s) in RCA: 26] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/07/2003] [Revised: 06/26/2003] [Accepted: 07/03/2003] [Indexed: 11/25/2022]
|
7
|
Săndulescu R, Florean E, Roman L, Mirel S, Oprean R, Suciu P. Spectrophotometric determination of fluoride in dosage forms and dental preparations. J Pharm Biomed Anal 1996; 14:951-8. [PMID: 8818000 DOI: 10.1016/s0731-7085(96)01745-1] [Citation(s) in RCA: 18] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/02/2023]
Abstract
The method is based upon the reaction between fluoride ions and the coloured complex of Fe(III) with methyl salicylate to form the stable, colourless hexaflouride complex of iron. The conditions of the method (pH, time and combination ratio) were studied and a standard curve was obtained for 0.01-0.08 mg NaF ml-1, at 525 nm. A study was conducted on interference with complexing anions of Fe(III), cations that react with fluoride ions and with common ingredients of dosage forms and dental preparations. The method was validated and the results showed good precision (100.16 +/- = 2.33%) comparable with that of other analytical methods. Good results were obtained in the spectrophotometric determination of fluoride ions in a stomatological gel and in a toothpaste.
Collapse
Affiliation(s)
- R Săndulescu
- Department of Analytical Chemistry, Faculty of Pharmacy, University of Medicine and Pharmacy, Iuliu Hatieganu, Cluj-Napoca, Romania
| | | | | | | | | | | |
Collapse
|