1
|
Mach M, Szalkiewicz P, Poschner T, Hasan W, Andreas M, Winkler B, Hasimbegovic E, Steinkellner T, Strouhal A, Adlbrecht C, Delle-Karth G, Grabenwöger M. The use of semi-compliant versus non-compliant balloon systems for predilatation during the implantation of self-expandable transcatheter aortic valves: Data from the VIenna CardioThOracic Aortic Valve RegistrY (VICTORY). Eur J Clin Invest 2021; 51:e13570. [PMID: 33954997 PMCID: PMC8459263 DOI: 10.1111/eci.13570] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/07/2021] [Revised: 02/11/2021] [Accepted: 04/01/2021] [Indexed: 11/28/2022]
Abstract
BACKGROUND This study aimed to evaluate the differences in outcome arising from the use of semi-compliant (SCB) versus non-compliant balloon (NCB) systems for predilatation during self-expanding transcatheter aortic valve replacement (TAVR). METHODS 251 TAVR procedures with the implantation of self-expanding valves after predilatation were analyzed. SCB systems were used in 166 and NCB systems in 85 patients. The primary endpoint was defined as device success, a composite endpoint comprising the absence of procedural mortality, correct valve positioning, adequate valve performance and the absence of more than a mild paravalvular leak. The secondary endpoints were chosen in accordance with the valve academic research consortium (VARC-2) endpoint definitions. RESULTS No significant differences were observed with regard to procedural device success between the SCB- and NCB cohort (SCB: 142 [85.5%%] vs. NCB: 77 [90.6%]; P = .257). There was a notable difference between the rates of conversion to open surgery and the postdilatation rate, both of which were higher for the NCB group (SCB: 1 [0.6%] vs. NCB: 4 [5.1%]; P = .042; SCB: 30 [18.1%] vs. NCB: 34 [40%]; P < .001). In a multivariate logistic regression analysis, the use of semi-compliant balloon systems for predilatation was associated with a lower risk for postdilatation (OR: 0.296; 95% CI: 0.149-0.588) and conversion to open surgery (OR: 0.205; 95% CI: 0.085-0.493; P = .001) but not for device success. CONCLUSION While the balloon compliance did not affect the procedural mortality, device success or the rate of paravalvular leakage, the use of semi-compliant balloons for predilatation during TAVR should be investigated in larger randomized trials in the light of the lower rates of postdilatation and conversion to open surgery compared to their non-compliant counterparts.
Collapse
Affiliation(s)
- Markus Mach
- Department of Cardiac Surgery, Medical University of Vienna - Vienna General Hospital, Vienna, Austria.,Heart Team Vienna, Department of Cardio-Vascular Surgery, Clinic Floridsdorf and the Karl Landsteiner Institute for Cardio-Vascular Research, Vienna, Austria
| | - Philipp Szalkiewicz
- Department of Cardiac Surgery, Medical University of Vienna - Vienna General Hospital, Vienna, Austria.,Heart Team Vienna, Department of Cardio-Vascular Surgery, Clinic Floridsdorf and the Karl Landsteiner Institute for Cardio-Vascular Research, Vienna, Austria
| | - Thomas Poschner
- Department of Cardiac Surgery, Medical University of Vienna - Vienna General Hospital, Vienna, Austria
| | - Waseem Hasan
- Faculty of Medicine, Imperial College London, London, UK
| | - Martin Andreas
- Department of Cardiac Surgery, Medical University of Vienna - Vienna General Hospital, Vienna, Austria
| | - Bernhard Winkler
- Heart Team Vienna, Department of Cardio-Vascular Surgery, Clinic Floridsdorf and the Karl Landsteiner Institute for Cardio-Vascular Research, Vienna, Austria
| | - Ena Hasimbegovic
- Department of Cardiac Surgery, Medical University of Vienna - Vienna General Hospital, Vienna, Austria.,Division of Cardiology, Department of Internal Medicine II, Medical University of Vienna - Vienna General Hospital, Vienna, Austria
| | - Theresia Steinkellner
- Division of Anatomy, Center of Anatomy and Cell Biology, Medical University of Vienna - Vienna General Hospital, Vienna, Austria
| | - Andreas Strouhal
- Department of Cardiology, Clinic Floridsdorf and the Karl Landsteiner Institute for Cardiovascular and Critical Care Research, Vienna, Austria
| | - Christopher Adlbrecht
- Department of Cardiology, Clinic Floridsdorf and the Karl Landsteiner Institute for Cardiovascular and Critical Care Research, Vienna, Austria.,Imed19-privat, private clinical research center, Vienna, Austria
| | - Georg Delle-Karth
- Department of Cardiology, Clinic Floridsdorf and the Karl Landsteiner Institute for Cardiovascular and Critical Care Research, Vienna, Austria
| | - Martin Grabenwöger
- Heart Team Vienna, Department of Cardio-Vascular Surgery, Clinic Floridsdorf and the Karl Landsteiner Institute for Cardio-Vascular Research, Vienna, Austria.,Medical faculty, Sigmund Freud University, Vienna, Austria
| |
Collapse
|
2
|
Tenaglia AN, Schreiter S, Simonsen J, Hadi A. Effect of balloon material and inflation strategy on arterial trauma and mechanisms of percutaneous transluminal coronary angioplasty as determined by intracoronary ultrasound. Am J Cardiol 1999; 83:1124-6, A9. [PMID: 10190532 DOI: 10.1016/s0002-9149(99)00026-0] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
Abstract
Twenty-three patients were randomized to a minimally invasive strategy or to standard percutaneous transluminal coronary angioplasty followed by intracoronary ultrasound. There was no difference in intracoronary ultrasound-determined dissection after the procedure in the 2 groups, and the mechanism of lumen enlargement by percutaneous transluminal coronary angioplasty in both groups predominantly was due to vessel stretch.
Collapse
Affiliation(s)
- A N Tenaglia
- Cardiology Section, Tulane University Medical Center, New Orleans, Louisiana 70112, USA.
| | | | | | | |
Collapse
|