1
|
Rate dependent neural responses of interaural-time-difference cues in fine-structure and envelope. PeerJ 2024; 12:e17104. [PMID: 38680894 PMCID: PMC11055513 DOI: 10.7717/peerj.17104] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/07/2023] [Accepted: 02/22/2024] [Indexed: 05/01/2024] Open
Abstract
Advancements in cochlear implants (CIs) have led to a significant increase in bilateral CI users, especially among children. Yet, most bilateral CI users do not fully achieve the intended binaural benefit due to potential limitations in signal processing and/or surgical implant positioning. One crucial auditory cue that normal hearing (NH) listeners can benefit from is the interaural time difference (ITD), i.e., the time difference between the arrival of a sound at two ears. The ITD sensitivity is thought to be heavily relying on the effective utilization of temporal fine structure (very rapid oscillations in sound). Unfortunately, most current CIs do not transmit such true fine structure. Nevertheless, bilateral CI users have demonstrated sensitivity to ITD cues delivered through envelope or interaural pulse time differences, i.e., the time gap between the pulses delivered to the two implants. However, their ITD sensitivity is significantly poorer compared to NH individuals, and it further degrades at higher CI stimulation rates, especially when the rate exceeds 300 pulse per second. The overall purpose of this research thread is to improve spatial hearing abilities in bilateral CI users. This study aims to develop electroencephalography (EEG) paradigms that can be used with clinical settings to assess and optimize the delivery of ITD cues, which are crucial for spatial hearing in everyday life. The research objective of this article was to determine the effect of CI stimulation pulse rate on the ITD sensitivity, and to characterize the rate-dependent degradation in ITD perception using EEG measures. To develop protocols for bilateral CI studies, EEG responses were obtained from NH listeners using sinusoidal-amplitude-modulated (SAM) tones and filtered clicks with changes in either fine structure ITD (ITDFS) or envelope ITD (ITDENV). Multiple EEG responses were analyzed, which included the subcortical auditory steady-state responses (ASSRs) and cortical auditory evoked potentials (CAEPs) elicited by stimuli onset, offset, and changes. Results indicated that acoustic change complex (ACC) responses elicited by ITDENV changes were significantly smaller or absent compared to those elicited by ITDFS changes. The ACC morphologies evoked by ITDFS changes were similar to onset and offset CAEPs, although the peak latencies were longest for ACC responses and shortest for offset CAEPs. The high-frequency stimuli clearly elicited subcortical ASSRs, but smaller than those evoked by lower carrier frequency SAM tones. The 40-Hz ASSRs decreased with increasing carrier frequencies. Filtered clicks elicited larger ASSRs compared to high-frequency SAM tones, with the order being 40 > 160 > 80> 320 Hz ASSR for both stimulus types. Wavelet analysis revealed a clear interaction between detectable transient CAEPs and 40-Hz ASSRs in the time-frequency domain for SAM tones with a low carrier frequency.
Collapse
Affiliation(s)
- Hongmei Hu
- SOUND Lab, Cambridge Hearing Group, Department of Clinical Neuroscience, Cambridge University, Cambridge, United Kingdom
- Department of Medical Physics and Acoustics, Carl von Ossietzky University of Oldenburg, Oldenburg, Germany
| | - Stephan D. Ewert
- Department of Medical Physics and Acoustics, Carl von Ossietzky University of Oldenburg, Oldenburg, Germany
| | - Birger Kollmeier
- Department of Medical Physics and Acoustics, Carl von Ossietzky University of Oldenburg, Oldenburg, Germany
| | - Deborah Vickers
- SOUND Lab, Cambridge Hearing Group, Department of Clinical Neuroscience, Cambridge University, Cambridge, United Kingdom
| |
Collapse
|
2
|
Normative Study of the Binaural Interaction Component of the Human Auditory Brainstem Response as a Function of Interaural Time Differences. Ear Hear 2021; 42:629-643. [PMID: 33141776 PMCID: PMC8085190 DOI: 10.1097/aud.0000000000000964] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
Abstract
OBJECTIVES The binaural interaction component (BIC) of the auditory brainstem response (ABR) is obtained by subtracting the sum of the monaural right and left ear ABRs from the binaurally evoked ABR. The result is a small but prominent negative peak (herein called "DN1"), indicating a smaller binaural than summed ABR, which occurs around the latency of wave V or its roll-off slope. The BIC has been proposed to have diagnostic value as a biomarker of binaural processing abilities; however, there have been conflicting reports regarding the reliability of BIC measures in human subjects. The objectives of the current study were to: (1) examine prevalence of BIC across a large group of normal-hearing young adults; (2) determine effects of interaural time differences (ITDs) on BIC; and (3) examine any relationship between BIC and behavioral ITD discrimination acuity. DESIGN Subjects were 40 normal-hearing adults (20 males and 20 females), aged 21 to 48 years, with no history of otologic or neurologic disorders. Midline ABRs were recorded from electrodes at high forehead (Fz) referenced to the nape of the neck (near the seventh cervical vertebra), with Fpz (low forehead) as the ground. ABRs were also recorded with a conventional earlobe reference for comparison to midline results. Stimuli were 90 dB peSPL biphasic clicks. For BIC measurements, stimuli were presented in a block as interleaved right monaural, left monaural, and binaural stimuli with 2000+ presentations per condition. Four measurements were averaged for a total of 8000+ stimuli per analyzed waveform. BIC was measured for ITD = 0 (simultaneous bilateral) and for ITDs of ±500 and ±750 µs. Subjects separately performed a lateralization task, using the same stimuli, to determine ITD discrimination thresholds. RESULTS An identifiable BIC DN1 was obtained in 39 of 40 subjects at ITD = 0 µs in at least one of two measurement sessions, but was seen in lesser numbers of subjects in a single session or as ITD increased. BIC was most often seen when a subject was relaxed or sleeping, and less often when they fidgeted or reported neck tension, suggesting myogenic activity as a possible factor in disrupting BIC measurements. Mean BIC latencies systematically increased with increasing ITD, and mean BIC amplitudes tended to decrease. However, across subjects, there was no significant relationship between the amplitude or latency of the BIC and behavioral ITD thresholds. CONCLUSIONS Consistent with previous studies, measurement of the BIC was time consuming and a BIC was sometimes difficult to obtain in awake normal-hearing subjects. The BIC will thus continue to be of limited clinical utility unless stimulus parameters and measurement techniques can be identified that produce a more robust response. Nonetheless, modulation of BIC characteristics by ITD supports the concept that the ABR BIC indexes aspects of binaural brainstem processing and thus may prove useful in selected research applications, e.g. in the examination of populations expected to have aberrant binaural signal processing ability.
Collapse
Affiliation(s)
- Carol A. Sammeth
- Department of Physiology and Biophysics, University of Colorado School of Medicine, Aurora, Colorado, USA
| | - Nathaniel T. Greene
- Department of Otolaryngology, University of Colorado School of Medicine, Aurora, Colorado, USA
| | - Andrew D. Brown
- Department of Speech and Hearing Sciences, University of Washington, Seattle, Washington, USA
| | - Daniel J Tollin
- Department of Physiology and Biophysics, University of Colorado School of Medicine, Aurora, Colorado, USA
- Department of Otolaryngology, University of Colorado School of Medicine, Aurora, Colorado, USA
| |
Collapse
|
3
|
Between-ear sound frequency disparity modulates a brain stem biomarker of binaural hearing. J Neurophysiol 2019; 122:1110-1122. [PMID: 31314646 PMCID: PMC6766741 DOI: 10.1152/jn.00057.2019] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/24/2019] [Revised: 07/02/2019] [Accepted: 07/03/2019] [Indexed: 11/22/2022] Open
Abstract
The auditory brain stem response (ABR) is an evoked potential that indexes a cascade of neural events elicited by sound. In the present study we evaluated the influence of sound frequency on a derived component of the ABR known as the binaural interaction component (BIC). Specifically, we evaluated the effect of acoustic interaural (between-ear) frequency mismatch on BIC amplitude. Goals were to 1) increase basic understanding of sound features that influence this long-studied auditory potential and 2) gain insight about the persistence of the BIC with interaural electrode mismatch in human users of bilateral cochlear implants, presently a limitation on the prospective utility of the BIC in audiological settings. Data were collected in an animal model that is audiometrically similar to humans, the chinchilla (Chinchilla lanigera; 6 females). Frequency disparities and amplitudes of acoustic stimuli were varied over broad ranges, and associated variation of BIC amplitude was quantified. Subsequently, responses were simulated with the use of established models of the brain stem pathway thought to underlie the BIC. Collectively, the data demonstrate that at high sound intensities (≥85 dB SPL), the acoustically elicited BIC persisted with interaurally disparate stimulation (click frequencies ≥1.5 octaves apart). However, sharper tuning emerged at moderate sound intensities (65 dB SPL), with the largest BIC occurring for stimulus frequencies within ~0.8 octaves, equivalent to ±1 mm in cochlear place. Such responses were consistent with simulated responses of the presumed brain stem generator of the BIC, the lateral superior olive. The data suggest that leveraging focused electrical stimulation strategies could improve BIC-based bilateral cochlear implant fitting outcomes.NEW & NOTEWORTHY Traditional hearing tests evaluate each ear independently. Diagnosis and treatment of binaural hearing dysfunction remains a basic challenge for hearing clinicians. We demonstrate in an animal model that the prospective utility of a noninvasive electrophysiological signature of binaural function, the binaural interaction component (BIC), depends strongly on the intensity of auditory stimulation. Data suggest that more informative BIC measurements could be obtained with clinical protocols leveraging stimuli restricted in effective bandwidth.
Collapse
Affiliation(s)
- Andrew D Brown
- Department of Speech and Hearing Sciences, University of Washington, Seattle, Washington
| | - Kelsey L Anbuhl
- Center for Neural Science, New York University, New York, New York
| | - Jesse I Gilmer
- Department of Physiology and Biophysics, University of Colorado School of Medicine, Aurora, Colorado
- Neuroscience Training Program, University of Colorado School of Medicine, Aurora, Colorado
| | - Daniel J Tollin
- Department of Physiology and Biophysics, University of Colorado School of Medicine, Aurora, Colorado
- Neuroscience Training Program, University of Colorado School of Medicine, Aurora, Colorado
- Department of Otolaryngology, University of Colorado School of Medicine, Aurora, Colorado
| |
Collapse
|
4
|
|
5
|
A Cochlear Implant Performance Prognostic Test Based on Electrical Field Interactions Evaluated by eABR (Electrical Auditory Brainstem Responses). PLoS One 2016; 11:e0155008. [PMID: 27149268 PMCID: PMC4858145 DOI: 10.1371/journal.pone.0155008] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/28/2015] [Accepted: 04/22/2016] [Indexed: 11/18/2022] Open
Abstract
Background Cochlear implants (CIs) are neural prostheses that have been used routinely in the clinic over the past 25 years. They allow children who were born profoundly deaf, as well as adults affected by hearing loss for whom conventional hearing aids are insufficient, to attain a functional level of hearing. The “modern” CI (i.e., a multi-electrode implant using sequential coding strategies) has yielded good speech comprehension outcomes (recognition level for monosyllabic words about 50% to 60%, and sentence comprehension close to 90%). These good average results however hide a very important interindividual variability as scores in a given patients’ population often vary from 5 to 95% in comparable testing conditions. Our aim was to develop a prognostic model for patients with unilateral CI. A novel method of objectively measuring electrical and neuronal interactions using electrical auditory brainstem responses (eABRs) is proposed. Methods and Findings The method consists of two measurements: 1) eABR measurements with stimulation by a single electrode at 70% of the dynamic range (four electrodes distributed within the cochlea were tested), followed by a summation of these four eABRs; 2) Measurement of a single eABR with stimulation from all four electrodes at 70% of the dynamic range. A comparison of the eABRs obtained by these two measurements, defined as the monaural interaction component (MIC), indicated electrical and neural interactions between the stimulation channels. Speech recognition performance without lip reading was measured for each patient using a logatome test (64 "vowel-consonant-vowel"; VCV; by forced choice of 1 out of 16). eABRs were measured in 16 CI patients (CIs with 20 electrodes, Digisonic SP; Oticon Medical ®, Vallauris, France). Significant correlations were found between speech recognition performance and the ratio of the amplitude of the V wave of the eABRs obtained with the two measurements (Pearson's linear regression model, parametric correlation: r2 = 0.26, p<0.05). Conclusions This prognostic model allowed a substantial amount of the interindividual variance in speech recognition scores to be explained. The present study used measurements of electrical and neuronal interactions by eABR to assess patients' bio-electric capacity to use multiple information channels supplied by the implant. This type of prognostic information may be valuable in several ways. On the patient level, it allows customizing of individual treatments. ClinicalTrials.gov Identifier: NCT01805167
Collapse
Affiliation(s)
- Nicolas Guevara
- University Head and Neck Institute, CHU de Nice, 31 Avenue de Valombrose, 06107 Nice cedex 2, France
| | - Michel Hoen
- Oticon Medical, Clinical and Scientific Research Department, 2720 chemin St Bernard, 06220 Vallauris, France
| | - Eric Truy
- Department of Audiology and Otorhinolaryngology, Edouard Herriot Hospital, 5 Place d'Arsonval, 69437 Lyon, France
| | - Stéphane Gallego
- Institute for Readaptation Sciences and Techniques, 8 Avenue Rockefeller, 69373 Lyon Cedex 08, France
| |
Collapse
|
6
|
Suitability of the Binaural Interaction Component for Interaural Electrode Pairing of Bilateral Cochlear Implants. ADVANCES IN EXPERIMENTAL MEDICINE AND BIOLOGY 2016; 894:57-64. [PMID: 27080646 DOI: 10.1007/978-3-319-25474-6_7] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/11/2023]
Abstract
Although bilateral cochlear implants (BiCIs) have succeeded in improving the spatial hearing performance of bilateral CI users, the overall performance is still not comparable with normal hearing listeners. Limited success can be partially caused by an interaural mismatch of the place-of-stimulation in each cochlea. Pairing matched interaural CI electrodes and stimulating them with the same frequency band is expected to facilitate binaural functions such as binaural fusion, localization, or spatial release from masking. It has been shown in animal experiments that the magnitude of the binaural interaction component (BIC) derived from the wave-eV decreases for increasing interaural place of stimulation mismatch. This motivated the investigation of the suitability of an electroencephalography-based objective electrode-frequency fitting procedure based on the BIC for BiCI users. A 61 channel monaural and binaural electrically evoked auditory brainstem response (eABR) recording was performed in 7 MED-EL BiCI subjects so far. These BiCI subjects were directly stimulated at 60% dynamic range with 19.9 pulses per second via a research platform provided by the University of Innsbruck (RIB II). The BIC was derived for several interaural electrode pairs by subtracting the response from binaural stimulation from their summed monaural responses. The BIC based pairing results are compared with two psychoacoustic pairing methods: interaural pulse time difference sensitivity and interaural pitch matching. The results for all three methods analyzed as a function of probe electrode allow for determining a matched pair in more than half of the subjects, with a typical accuracy of ± 1 electrode. This includes evidence for statistically significant tuning of the BIC as a function of probe electrode in human subjects. However, results across the three conditions were sometimes not consistent. These discrepancies will be discussed in the light of pitch plasticity versus less plastic brainstem processing.
Collapse
Affiliation(s)
- Hongmei Hu
- Medizinische Physik, Universität Oldenburg, Cluster of Excellence "Hearing4all", 26111, Oldenburg, Germany.
| | - Birger Kollmeier
- Medizinische Physik, Universität Oldenburg, Cluster of Excellence "Hearing4all", 26111, Oldenburg, Germany
| | - Mathias Dietz
- Medizinische Physik, Universität Oldenburg, Cluster of Excellence "Hearing4all", 26111, Oldenburg, Germany
| |
Collapse
|
7
|
A Comparison of Two Objective Measures of Binaural Processing: The Interaural Phase Modulation Following Response and the Binaural Interaction Component. Trends Hear 2015; 19:19/0/2331216515619039. [PMID: 26721925 PMCID: PMC4771038 DOI: 10.1177/2331216515619039] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022] Open
Abstract
There has been continued interest in clinical objective measures of binaural processing. One commonly proposed measure is the binaural interaction component (BIC), which is obtained typically by recording auditory brainstem responses (ABRs)—the BIC reflects the difference between the binaural ABR and the sum of the monaural ABRs (i.e., binaural − (left + right)). We have recently developed an alternative, direct measure of sensitivity to interaural time differences, namely, a following response to modulations in interaural phase difference (the interaural phase modulation following response; IPM-FR). To obtain this measure, an ongoing diotically amplitude-modulated signal is presented, and the interaural phase difference of the carrier is switched periodically at minima in the modulation cycle. Such periodic modulations to interaural phase difference can evoke a steady state following response. BIC and IPM-FR measurements were compared from 10 normal-hearing subjects using a 16-channel electroencephalographic system. Both ABRs and IPM-FRs were observed most clearly from similar electrode locations—differential recordings taken from electrodes near the ear (e.g., mastoid) in reference to a vertex electrode (Cz). Although all subjects displayed clear ABRs, the BIC was not reliably observed. In contrast, the IPM-FR typically elicited a robust and significant response. In addition, the IPM-FR measure required a considerably shorter recording session. As the IPM-FR magnitude varied with interaural phase difference modulation depth, it could potentially serve as a correlate of perceptual salience. Overall, the IPM-FR appears a more suitable clinical measure than the BIC.
Collapse
Affiliation(s)
- Nicholas R Haywood
- UCL Ear Institute, UCL School of Life and Medical Sciences, University College London, UK
| | - Jaime A Undurraga
- UCL Ear Institute, UCL School of Life and Medical Sciences, University College London, UK
| | - Torsten Marquardt
- UCL Ear Institute, UCL School of Life and Medical Sciences, University College London, UK
| | - David McAlpine
- UCL Ear Institute, UCL School of Life and Medical Sciences, University College London, UK
| |
Collapse
|
8
|
Abstract
In patients with bilateral cochlear implants (CIs), pairing matched interaural electrodes and stimulating them with the same frequency band is expected to facilitate binaural functions such as binaural fusion, localization, and spatial release from masking. Because clinical procedures typically do not include patient-specific interaural electrode pairing, it remains the case that each electrode is allocated to a generic frequency range, based simply on the electrode number. Two psychoacoustic techniques for determining interaurally paired electrodes have been demonstrated in several studies: interaural pitch comparison and interaural time difference (ITD) sensitivity. However, these two methods are rarely, if ever, compared directly. A third, more objective method is to assess the amplitude of the binaural interaction component (BIC) derived from electrically evoked auditory brainstem responses for different electrode pairings; a method has been demonstrated to be a potential candidate for bilateral CI users. Here, we tested all three measures in the same eight CI users. We found good correspondence between the electrode pair producing the largest BIC and the electrode pair producing the maximum ITD sensitivity. The correspondence between the pairs producing the largest BIC and the pitch-matched electrode pairs was considerably weaker, supporting the previously proposed hypothesis that whilst place pitch might adapt over time to accommodate mismatched inputs, sensitivity to ITDs does not adapt to the same degree.
Collapse
Affiliation(s)
- Hongmei Hu
- Medizinische Physik, Universität Oldenburg and Cluster of Excellence "Hearing4all", Germany
| | - Mathias Dietz
- Medizinische Physik, Universität Oldenburg and Cluster of Excellence "Hearing4all", Germany
| |
Collapse
|
9
|
Binaural interaction in the auditory brainstem response: A normative study. Clin Neurophysiol 2015; 126:772-9. [DOI: 10.1016/j.clinph.2014.07.032] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/11/2013] [Revised: 06/26/2014] [Accepted: 07/27/2014] [Indexed: 11/27/2022]
|
10
|
Envelope enhancement increases cortical sensitivity to interaural envelope delays with acoustic and electric hearing. PLoS One 2014; 9:e104097. [PMID: 25093417 PMCID: PMC4122409 DOI: 10.1371/journal.pone.0104097] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/24/2013] [Accepted: 07/10/2014] [Indexed: 11/20/2022] Open
Abstract
Evidence from human psychophysical and animal electrophysiological studies suggests that sensitivity to interaural time delay (ITD) in the modulating envelope of a high-frequency carrier can be enhanced using half-wave rectified stimuli. Recent evidence has shown potential benefits of equivalent electrical stimuli to deaf individuals with bilateral cochlear implants (CIs). In the current study we assessed the effects of envelope shape on ITD sensitivity in the primary auditory cortex of normal-hearing ferrets, and profoundly-deaf animals with bilateral CIs. In normal-hearing animals, cortical sensitivity to ITDs (±1 ms in 0.1-ms steps) was assessed in response to dichotically-presented i) sinusoidal amplitude-modulated (SAM) and ii) half-wave rectified (HWR) tones (100-ms duration; 70 dB SPL) presented at the best-frequency of the unit over a range of modulation frequencies. In separate experiments, adult ferrets were deafened with neomycin administration and bilaterally-implanted with intra-cochlear electrode arrays. Electrically-evoked auditory brainstem responses (EABRs) were recorded in response to bipolar electrical stimulation of the apical pair of electrodes with singe biphasic current pulses (40 µs per phase) over a range of current levels to measure hearing thresholds. Subsequently, we recorded cortical sensitivity to ITDs (±800 µs in 80-µs steps) within the envelope of SAM and HWR biphasic-pulse trains (40 µs per phase; 6000 pulses per second, 100-ms duration) over a range of modulation frequencies. In normal-hearing animals, nearly a third of cortical neurons were sensitive to envelope-ITDs in response to SAM tones. In deaf animals with bilateral CI, the proportion of ITD-sensitive cortical neurons was approximately a fifth in response to SAM pulse trains. In normal-hearing and deaf animals with bilateral CI the proportion of ITD sensitive units and neural sensitivity to ITDs increased in response to HWR, compared with SAM stimuli. Consequently, novel stimulation strategies based on envelope enhancement may prove beneficial to individuals with bilateral cochlear implants.
Collapse
Affiliation(s)
- Douglas E. H. Hartley
- NIHR National Biomedical Research Unit in Hearing, Ropewalk House, Nottingham, United Kingdom
- Department of Otolaryngology, School of Clinical Sciences, Nottingham University, Nottingham, United Kingdom
- Medical Research Council Institute of Hearing Research, University Park, Nottingham, United Kingdom
- Department of Physiology, Anatomy & Genetics, University of Oxford, Oxford, United Kingdom
| | - Amal Isaiah
- Department of Physiology, Anatomy & Genetics, University of Oxford, Oxford, United Kingdom
| |
Collapse
|
11
|
Central masking with bilateral cochlear implants. THE JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA 2013; 133:962-969. [PMID: 23363113 PMCID: PMC3574098 DOI: 10.1121/1.4773262] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/22/2011] [Revised: 11/29/2012] [Accepted: 12/03/2012] [Indexed: 06/01/2023]
Abstract
Across bilateral cochlear implants, contralateral threshold shift has been investigated as a function of electrode difference between the masking and probe electrodes. For contralateral electric masking, maximum threshold elevations occurred when the position of the masker and probe electrode was approximately place-matched across ears. The amount of masking diminished with increasing masker-probe electrode separation. Place-dependent masking occurred in both sequentially implanted ears, and was not affected by the masker intensity or the time delay from the masker onset. When compared to previous contralateral masking results in normal hearing, the similarities between place-dependent central masking patterns suggest comparable mechanisms of overlapping excitation in the central auditory nervous system.
Collapse
Affiliation(s)
- Payton Lin
- Department of Biomedical Engineering, University of California, Irvine, California 92617, USA.
| | | | | |
Collapse
|
12
|
Contrasting benefits from contralateral implants and hearing aids in cochlear implant users. Hear Res 2012; 288:100-13. [DOI: 10.1016/j.heares.2011.11.014] [Citation(s) in RCA: 59] [Impact Index Per Article: 4.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/03/2011] [Revised: 11/28/2011] [Accepted: 11/30/2011] [Indexed: 11/26/2022]
|
13
|
Preliminary results of the relationship between the binaural interaction component of the electrically evoked auditory brainstem response and interaural pitch comparisons in bilateral cochlear implant recipients. Ear Hear 2012; 33:57-68. [PMID: 21730858 DOI: 10.1097/aud.0b013e31822519ef] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
Abstract
OBJECTIVE : The purpose of this study was to investigate the relationship between electrophysiologic measures of the binaural interaction component (BIC) of the electrically evoked auditory brainstem response and psychophysical measures of interaural pitch comparisons in Nucleus bilateral cochlear implant users. DESIGN : Data were collected for 10 postlingually deafened adult cochlear implant users. Each subject conducted an interaural pitch-comparison task using a biphasic pulse train with a pulse rate of 1000 pulses per second (pps) at high stimulation levels. Stimuli were presented in a two-interval, two-alternative forced-choice procedure with roving current variations. A subgroup of four subjects repeated the task at low stimulation levels. BICs were measured using loudness balanced, biphasic current pulses presented at a rate of 19.9 pps for each subject by pairing the electrode 12 (out of 22 intracochlear electrodes) in the right ear with each of 11 electrodes spaced across the electrode array in the left ear. The BIC was measured at high stimulation levels in 10 subjects and at low stimulation levels in 7 subjects. Because of differences in stimulation rate used in BIC measures and interaural pitch comparisons, the actual stimulation levels were different in these two measures. The relationship between BIC responses and results of interaural pitch comparisons was evaluated for each of the individual subjects and at the group level. Evaluation was carried out separately for results obtained at high and low stimulation levels. RESULTS : There was no significant correlation between results of BIC measures and interaural pitch comparisons on either the individual or group levels. Lower stimulation level did not improve the relationship between these two measures. CONCLUSIONS : No significant correlations between psychophysical measures of interaural pitch comparisons and electrophysiologic measures of the BIC of the electrically evoked auditory brainstem response were found. The lack of correlation may be attributed to methods used to quantify the data, small number of subjects retested at low stimulation levels, and central processing components involved in the interaural pitch-comparison task.
Collapse
|
14
|
|
15
|
Effects of stimulation level and electrode pairing on the binaural interaction component of the electrically evoked auditory brain stem response. Ear Hear 2010; 31:457-70. [PMID: 20418771 DOI: 10.1097/aud.0b013e3181d5d9bf] [Citation(s) in RCA: 19] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
Abstract
OBJECTIVES The purpose of this study was to investigate the effects of stimulation level and electrode pairing on the binaural interaction component (BIC) of the electrically evoked auditory brain stem response (EABR) in Nucleus cochlear implant (CI) users. DESIGN Ten postlingually deafened adult CI users participated in this study. EABRs were measured using loudness balanced, biphasic current pulses presented in the left monaural, right monaural, and bilateral stimulation conditions. BICs were computed based on measures of the EABR obtained for each subject by pairing the electrode 12 (of 22 intracochlear electrodes) in the right ear with each of 11 electrodes spaced across the electrode array in the left ear. The effect of stimulation level on the amplitude of the BIC was investigated by measuring growth functions of the BIC from six subjects. The effect of electrode pairing on the amplitude of the BIC was studied at high stimulation levels in 10 subjects and at low stimulation levels in seven subjects. The high stimulation level was chosen as the 90% point of the subject's dynamic range (DR) or the highest stimulation level in which the electrophysiologic recordings were not contaminated by muscle artifacts. The low stimulation level was chosen as a level that was 10% point of subject's DR higher than the BIC threshold for six of these seven subjects. For one subject, BIC thresholds were not available and the low stimulation level was referred to the 70% point of subject's DR. RESULTS BICs were successfully recorded from all 11 interaural electrode pairs for a majority of subjects tested at both stimulation levels. BIC amplitudes increased with stimulation level. The effect of stimulation level on latencies of the BIC was less robust. At high stimulation levels, BIC amplitudes did not change significantly as the stimulating electrode used in the left ear was systematically varied. When low stimulation levels were used, BIC amplitude was maximal for interaural electrode pairs with similar intracochlear positions and decreased when the offset between interaural electrodes increased. CONCLUSIONS This study demonstrates that stimulation level affects amplitudes of the BIC response. It is possible to record the BIC of the EABR in bilateral CI users even from interaural electrode pairs that have large interaural offsets. This finding suggests that when high-level stimuli are used, there is a broad pattern of current spread within the two cochleae. At lower stimulation levels, the spread of excitation within the cochlea is reduced making the effect of electrode pairing on the amplitude of the BIC more pronounced.
Collapse
|
16
|
Sensitivity to interaural time difference with bilateral cochlear implants: Development over time and effect of interaural electrode spacing. THE JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA 2009; 126:806-15. [PMID: 19640045 PMCID: PMC2730718 DOI: 10.1121/1.3158821] [Citation(s) in RCA: 63] [Impact Index Per Article: 4.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/10/2023]
Abstract
Sensitivity to interaural time difference (ITD) in constant-amplitude pulse trains was measured in four sequentially implanted bilateral cochlear implant (CI) subjects. The sensitivity measurements were made as a function of time beginning directly after the second ear was implanted, continued for periods of months before subjects began wearing bilateral sound processors, and extended for months while the subjects used bilateral sound processors in day-to-day listening. Measurements were also made as a function of the relative position of the left/right electrodes. The two subjects with the shortest duration of binaural deprivation before implantation demonstrated ITD sensitivity soon after second-ear implantation (before receiving the second sound processor), while the other two did not demonstrate sensitivity until after months of daily experience using bilateral processors. The interaural mismatch in electrode position required to decrease ITD sensitivity by a factor of 2 (half-width) for CI subjects was five times greater than the half-width for interaural carrier-frequency disparity in normal-hearing subjects listening to sinusoidally amplitude-modulated high-frequency tones. This large half-width is likely to contribute to poor binaural performance in CI users, especially in environments with multiple broadband sound sources.
Collapse
Affiliation(s)
- Becky B Poon
- Cochlear Implant Research Laboratory, Massachusetts Eye and Ear Infirmary, Boston, MA 02114, USA
| | | | | | | |
Collapse
|
17
|
Binaural interactions of electrically and acoustically evoked responses recorded from the inferior colliculus of guinea pigs. Int J Audiol 2007; 46:309-20. [PMID: 17530515 DOI: 10.1080/14992020701212622] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/23/2022]
Abstract
Binaural interactions within the inferior colliculus (IC) elicited by electric and acoustic stimuli were investigated in this study. Using a guinea pig model, binaural acoustic stimuli were presented with different time delays, as were combinations of binaural electric and acoustic stimuli. Averaged evoked potentials were measured using electrodes inserted into the central nucleus of the IC to obtain the binaural interaction component (BIC), computed by subtracting the sum of the two monaural responses from the binaural response. The BICs to acoustic-acoustic stimulation and electric-acoustic stimulation were found to be similar. The BIC amplitude increased with stimulus intensity, but the shapes of the delay functions were similar across the levels tested. The gross-potential data are thus consistent with the thesis that the central auditory system processes binaural electric and acoustic stimuli in a similar manner. These results suggest that the binaural auditory system can process combinations of electric and acoustic stimulation presented across ears and that evoked gross potentials may be used to measure such interaction.
Collapse
Affiliation(s)
- Heil Noh
- Department of Otolaryngology-Head and Neck Surgery, College of Medicine, The Catholic University of Korea, Seoul, Korea.
| | | | | | | | | | | |
Collapse
|
18
|
Using evoked potentials to match interaural electrode pairs with bilateral cochlear implants. J Assoc Res Otolaryngol 2007; 8:134-51. [PMID: 17225976 PMCID: PMC1907379 DOI: 10.1007/s10162-006-0069-0] [Citation(s) in RCA: 35] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/18/2006] [Accepted: 12/10/2006] [Indexed: 10/23/2022] Open
Abstract
Bilateral cochlear implantation seeks to restore the advantages of binaural hearing to the profoundly deaf by providing binaural cues normally important for accurate sound localization and speech reception in noise. Psychophysical observations suggest that a key issue for the implementation of a successful binaural prosthesis is the ability to match the cochlear positions of stimulation channels in each ear. We used a cat model of bilateral cochlear implants with eight-electrode arrays implanted in each cochlea to develop and test a noninvasive method based on evoked potentials for matching interaural electrodes. The arrays allowed the cochlear location of stimulation to be independently varied in each ear. The binaural interaction component (BIC) of the electrically evoked auditory brainstem response (EABR) was used as an assay of binaural processing. BIC amplitude peaked for interaural electrode pairs at the same relative cochlear position and dropped with increasing cochlear separation in either direction. To test the hypothesis that BIC amplitude peaks when electrodes from the two sides activate maximally overlapping neural populations, we measured multiunit neural activity along the tonotopic gradient of the inferior colliculus (IC) with 16-channel recording probes and determined the spatial pattern of IC activation for each stimulating electrode. We found that the interaural electrode pairings that produced the best aligned IC activation patterns were also those that yielded maximum BIC amplitude. These results suggest that EABR measurements may provide a method for assigning frequency-channel mappings in bilateral implant recipients, such as pediatric patients, for which psychophysical measures of pitch ranking or binaural fusion are unavailable.
Collapse
Affiliation(s)
- Zachary M Smith
- Eaton-Peabody Laboratory, Massachusetts Eye and Ear Infirmary, Boston, MA, USA.
| | | |
Collapse
|
19
|
Binaural sensitivity as a function of interaural electrode position with a bilateral cochlear implant user. THE JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA 2003; 114:1565-1574. [PMID: 14514210 DOI: 10.1121/1.1603765] [Citation(s) in RCA: 78] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/24/2023]
Abstract
Experiments were conducted with a single, bilateral cochlear implant user to examine interaural level and time-delay cues that putatively underlie the design and efficacy of bilateral implant systems. The subject's two implants were of different types but custom equipment allowed presentation of controlled bilateral stimuli, particularly those with specified interaural time difference (ITD) and interaural level difference (ILD) cues. A lateralization task was used to measure the effect of these cues on the perceived location of the sensations elicited. For trains of fixed-amplitude, biphasic current pulses at 100 pps, the subject demonstrated sensitivity to an ITD of 300 micros, providing evidence of access to binaural information. The choice of bilateral electrode pair greatly influenced ITD sensitivity, suggesting that electrode pairings are likely to be an important consideration in the effort to provide binaural advantages. The selection of bilateral electrode pairs showing sensitivity to ITD was partially aided by comparisons of the pitch elicited by individual electrodes in each ear (when stimulated alone with fixed-amplitude current pulses at 813 pps): specifically, interaural electrodes with similar pitches were more likely (but not certain) to show ITD sensitivity. Significant changes in lateral position occurred with specific electrode pairs. With five bilateral electrode pairs of 14 tested, ITDs of 300 and 600 micros moved an auditory image significantly from right to left. With these same pairs, ILD changes of approximately 11% of the dynamic range (in microApp) moved an auditory image from the far left to the far right-significantly farther than the nine pairs not showing significant ITD sensitivity. However, even these nine pairs did show response changes as a function of the interaural (or confounding monaural) level cue. Overall, insofar as the access to bilateral cues demonstrated herein generalizes to other subjects, it provides hope that the normal binaural advantages for speech recognition and sound localization can be made available to bilateral implant users.
Collapse
Affiliation(s)
- Christopher J Long
- Speech and Hearing Sciences Program, Division of Health Sciences and Technology, Massachusetts Institute of Technology, 77 Massachusetts Avenue, Cambridge, Massachusetts 02139, USA.
| | | | | | | |
Collapse
|
20
|
Electrophysiological findings in two bilateral cochlear implant cases: does the duration of deafness affect electrically evoked auditory brain stem responses? Ann Otol Rhinol Laryngol 2002; 111:1008-14. [PMID: 12450176 DOI: 10.1177/000348940211101111] [Citation(s) in RCA: 19] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
Bilateral cochlear implantation provides an interesting model for in vivo study of the effect of long-term profound deafness on neural transmission. We present electrophysiological observations on 2 patients implanted with the MXM Binaural Digisonic Convex system. This uncommon design consists of 2 electrode arrays placed bilaterally into the scala tympani and controlled by a single speech processor. In both patients, the duration of deafness before cochlear implantation clearly differed from one ear to the other. Electrically evoked auditory brain stem responses (EABRs) were measured and the EABRs from the ear with the longer deafness duration showed a lengthening of wave V latency. In I patient, recordings from this ear also showed a lack of reproducibility of wave III. The data suggest that neural responsiveness in the peripheral and intermediate auditory pathways is adversely affected by deafness duration. Poor EABRs on one ear possibly result from the total duration of deafness in this ear and/or compensation by the other ear.
Collapse
Affiliation(s)
- Hung Thai-Van
- Department of Audiology, CNRS UMR 5020, Edouard Herriot University Hospital, Lyon, France
| | | | | | | | | |
Collapse
|
21
|
Electrically evoked compound action potential (ECAP) of the cochlear nerve in response to pulsatile electrical stimulation of the cochlea in the rat: effects of stimulation at high rates. AUDIOLOGY : OFFICIAL ORGAN OF THE INTERNATIONAL SOCIETY OF AUDIOLOGY 1998; 37:353-71. [PMID: 9888192 DOI: 10.3109/00206099809072989] [Citation(s) in RCA: 31] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/13/2022]
Abstract
Some cochlear implant patients achieve better speech recognition with pulsatile electrical stimulation presented at high rates. The present study aimed to explore, in an animal model of cochlear implants, how the excitability of the cochlear nerve is affected by pulsatile electrical stimulation delivered at high rates, of up to 1,000-2,000 pulses per second (pps). Adult rats (n=23) were implanted with two or three stimulating electrodes in the left cochlea. In four of these rats, the left cochlea was deafened by local perfusion with 1 per cent or 4 per cent neomycin solutions prior to implantation. Pulsatile stimuli consisted of 20 micros electrical pulses, delivered in trains of 200 ms duration, separated by a pause of 200 ms. The pulse rates ranged from 100 to 2,000 pps (intra-train pulse rate). Electrically evoked compound action potentials (ECAPs) of the cochlear nerve were recorded either intracochlearly or from epidural electrodes (extra-cochlearly). With increasing pulse rates, the average ECAP amplitude decreased, whereas the average ECAP latency and its variability (SD) increased. For rates above 300 pps, the amplitude of the ECAP to the individual successive pulses delivered in the train progressively decreased during the initial part of the train, corresponding to a short-term adaptation of the cochlear nerve. This effect progressively increased for pulse rates ranging from 300 to 2,000 pps. In addition, there was a phenomenon of long-term adaptation, as indicated by a decrease in the amplitude of the ECAP to the first pulse of the train, indicating that the pause of 200 ms between each train was not long enough for full recovery of the cochlear nerve. This long-term adaptation was progressively more pronounced for increasing pulse rates. To characterize further the recovery in excitability of the cochlear nerve, forward masking experiments were conducted, showing a decrease of the ECAP amplitude when the interval between the first pulse (masker) and the second pulse (probe) was shorter than 2 ms. This ECAP decrease was slow for intervals between 2 and 1 ms and then abrupt for shorter intervals. The observations described above were similar for extra- and intra-cochlear recordings and were little, if at all, affected by treatment of the cochlea with neomycin.
Collapse
Affiliation(s)
- A Haenggeli
- Institute of Physiology, University of Fribourg, Switzerland
| | | | | | | | | |
Collapse
|
22
|
Auditory magnetic fields in cochlear-implant patients. Physiol Meas 1993; 14 Suppl 4A:A81-4. [PMID: 8274990 DOI: 10.1088/0967-3334/14/4a/014] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/29/2023]
Abstract
Neuromagnetic recordings were used to check if electrical stimulation of the auditory nerve in cochlear-implant patients activates cortical auditory areas in a similar manner as acoustic stimulation in normal hearing subjects or whether the excitation processes are different. The waveform of the evoked magnetic field complex elicited by electrical stimulation of the auditory nerve as well as the distribution of the magnetic responses over the head resemble that of auditory-evoked fields elicited by acoustic stimulation of normal subjects. The location and direction of the equivalent dipole are consistent with activation of the auditory cortex. Neuromagnetic recordings could be used in the future (i) to check activation of the auditory cortices in cochlear-implant patients; (ii) to gather information about the functional properties of this activity, and (iii) to study the integrity of central auditory pathways in totally deaf patients.
Collapse
Affiliation(s)
- M Pelizzone
- Department of Otolaryngology, Cantonal University Hospital, Geneva, Switzerland
| |
Collapse
|
23
|
Abstract
Two identical multichannel intracochlear prostheses were implanted in the same patient. The first prosthesis, implanted in the congenitally-deaf right ear, elicited clear sound perception but no speech recognition. After 2 years, a second prosthesis, implanted in the acquired-deaf left ear, enabled the patient to understand speech without lip-reading. Brainstem and middle-latency evoked potentials were similar with electrical stimulation of both ears and resembled those evoked by acoustic stimuli in subjects with normal hearing. Cortical electric and magnetic responses differed for right- and left-sided electrical stimulation suggesting that stimulation of the congenitally-deaf ear elicited an abnormal activation of the auditory cortex. These results suggest that only cortical responses were affected by the different histories of deafness of the ears.
Collapse
Affiliation(s)
- M Pelizzone
- Department of Otolaryngology, Cantonal University Hospital, Geneva, Switzerland
| | | | | | | | | |
Collapse
|